Ultrasonic root end cavity preparation assessed by an in situ impression technique

Similar documents
Root end preparation techniques Summary of papers

Comparison of the effect of Er, Cr-YSGG laser and ultrasonic retrograde root-end cavity preparation on the integrity of root apices

The Graduate School Yonsei University Department of Dentistry Myoungah Seo

SCANNING ELECTRON MICROSCOPE EVALUATION OF THE CUT ROOT SURFACE AND ROOT END PREPARATION USING VARIOUS TECHNIQUES

WaveOne Gold reciprocating instruments: clinical application in the private practice: Part 2

Comparison of the Different Techniques to Remove Fractured Endodontic Instruments from Root Canal Systems

Key words: Apicoectomy, scanning electron microscope, therapeutic ultrasound, endodontic surgery, dentinal crack.

Case Note Retrieval of a separated file using Masserann technique: A case report

ENDODONTOLOGY. An in-vitro evaluation of apical sealing of three epoxy resin based commercial preparations INTRODUCTION MATERIALS AND METHODS ABSTRACT

Comparison of removal of endodontic smear layer using NaOCl, EDTA, and different concentrations of maleic acid A SEM study

Staining Potential of Calcium Hydroxide and Monochlorophenol Following Removal of AH26 Root Canal Sealer

An In Vivo Evaluation of Two Types of Files used to Accurately Determine the Diameter of the Apical Constriction of a Root Canal: An In Vivo Study

In vitro evaluation of root canals obturated with four different techniques. Part 3: Obturation of lateral canals

In vitro evaluation of root canal preparation with plastic endodontic rotary finishing file - A SEM study

Large periapical lesion: Healing without knife and incision

Outcome of Root Canal Treatment Using Soft-Core and Cold Lateral Compaction Filling Techniques: A Randomized Clinical Trial

Smear layer removal evaluation of different protocol of Bio Race file and XPendo Finisher file in corporation with EDTA 17% and NaOCl

Comparison of Spreader Penetration during Lateral Compaction of 0.04 and 0.02 Tapered Gutta-Percha Master Cones

KING SAUD UNIVERSITY College of Dentistry. Department of Restorative Dental Sciences DIVISION OF ENDODONTICS COURSE OUTLINE 323 RDS

Dye Leakage of Four Root End Filling Materials: Effects of Blood Contamination

Apical Leakage Associated with Retrofilling Techniques: A Dye Study

ORIGINAL ARTICLE INTRODUCTION

A comparative analysis of microleakage of three root end filling materials an in vitro study

The Effect of Irrigation with Doxycycline or Citric Acid on Leakage and Osseous Wound Healing

A COMPARATIVE EVALUATION OF THE ACCURACY OF THIRD GENERATION ELECTRONIC APEX LOCATOR (ROOT ZX) IN PRESENCE OF VARIOUS INTRACANAL IRRIGANTS.

Scanning Electronic Microscopy Analysis of the Apical Surface After of Root-End Resection With Different Methods

Vertical Root Fracture and Root Distortion: Effect of Spreader Design

Evidence-based decision-making in endodontics

Case Report Endodontic Management of Maxillary Second Molar with Two Palatal Roots: A Report of Two Cases

Field Guide to the Ultrasonic Revolution

Maxillary Molar Endodontic Case Presentation. R.Bose. BDS (Manc 2010), General Dental Practitioner, Oxford/London.

Effects of Simulated Lateral Canals on the Accuracy of Measurements by an Electronic Apex Locator

Evaluation of apical and lateral extrusion of sealer using different sized thermoplastized obturators.

Case Report Endodontic Treatment of Bilateral Maxillary First Premolars with Three Roots Using CBCT: A Case Report

Cervical Root Resorption following Bleaching of Endodontically Treated Teeth

Comparison of White MTA And Grey MTA in the Apical Sealing Ability of Lased And Unlased Root Canal Walls - A Pilot Study

Educational Training Document

Clinical Management of a Maxillary Lateral Incisor With Vital Pulp and Type 3 Dens Invaginatus: A Case Report

Fundamentals of Endodontics Peter Briggs, Ahmed Farooq and Tracy Watford, Trish Moore and QED

1980 Harrison and Todd. The effect of root resection on the sealing property of root canal obturations.

ENDODONTOLOGY. Introduction. Original Research ABSTRACT

ENDODONTOLOGY ABSTRACT INTRODUCTION

Evaluation of Apical Sealing Ability of Three Different Root Canal Sealers.

COMBINED PERIODONTAL-ENDODONTIC LESION. By Dr. P.K. Agrawal Sr. Prof and Head Dept. Of Periodontia Govt. Dental College, Jaipur

Influence of cervical preflaring on apical file size determination - An in vitro study

Double-casting method for fixed prosthodontics with functionally generated path

Virtuosity is in your hands. Endodontic and Microsurgical Ultrasonic Instruments

INTERNATIONAL JOURNAL OF CURRENT RESEARCH IN CHEMISTRY AND PHARMACEUTICAL SCIENCES

Shah. Management of a maxillary second premolar with an S-shaped root canal - An endodontic. Management of a maxillary second premolar

J. Int Oral Health 2011 Case Report All right reserved

Journal of American Science 2014;10(12)

M. Zarrabian, et al Histologic Response to Retrofilling with MTA and Portland Cement

Endodontics. Lec.7 د. حسن الرماحي 5 th class. Obturation techniques

Dowel restorations Treatment with a post and core

Management of a Type III Dens Invaginatus using a Combination Surgical and Non-surgical Endodontic Therapy: A Case Report

Endodontics Cracked Tooth: How to manage it in daily practice

how to technique How to treat a cracked, but still inact, cusp. Disadvantages. 1 Issue Full coverage crown. >>

Corresponding Author:Dr.Sneha Vaidya 3

Diagnosis and Treatment of Three-Rooted Maxillary Premolars

Leakage along warm gutta-percha fillings in the apical canals of curved roots

Final Thesis Defense Examination. Anthony L. Horalek, DDS June 12, 2002

Principles of endodontic surgery

RESTORATIONS IN ENDODONTIC. Epita S. Pane Cons Dept FKG USU

Periapical Inflammation Affecting Coronallyinoculated Dog Teeth with Root Fillings Augmented by White MTA Orifice Plugs

Working length changes following straight-line access and different coronal flaring methods

Efficacy of microscopy and dye for determining the presence of root canals in root end resections-an in vitro study

Failed Root Canals: The Case for Apicoectomy (Periradicular Surgery)

Evaluation of retrievability using a new soft resin based root canal filling material

SCIENTIFIC INFORMATION. On the Gold Standard in Root Canal Sealer Materials SEALED. EFFECTIVE. PROVEN.

Endodontic treatment of mandibular incisors with two root canals: Report of two cases

Endodontics. Endodontic retreatment

The effects of file size, sodium hypochlorite and blood on the accuracy of Root ZX apex locator in enlarged root canals: an in vitro study

College Of Dental Sciences And Research, Ghaziabad, India

Treatment Options for the Compromised Tooth

Adaptation of Thermafil Components to Canal Walls

The accuracy of three different electronic root canal measuring devices: an in vitro evaluation

The Endodontics Introduction. By: Thulficar Al-Khafaji BDS, MSC, PhD

Endodontic perforation repair with light-cured glass ionomer

Conventional Management of Fractured Endodontic Instruments and Perforations

Surgical Retreatment of an Invaginated Maxillary Central Incisor Following Overfilled Endodontic Treatment: A Case Report

Microleakage of Root Canal Sealed with Temporary Endodontic Sealing Materials

Influence of plugger penetration depth on the area of the canal space occupied by gutta-percha

JCDP ABSTRACT INTRODUCTION /jp-journals

Endodontics And Pulp Biology: The Impact Clinically

Gorduysus MO et al. Operating Microscope improves ability to locate and negotiate second canal

Limited To Endodontics Newsletter. Limited To Endodontics A Practice Of Endodontic Specialists July Volume 2

DiaDent Group International DIA.DENT DiaRoot BioAggregate. Root Canal Repair Material

The influence of sensor size and orientation on image quality in intra-oral periapical radiography

Curriculum Vita. JAMAL AQRABAWI Associate professor, Endodontics Faculty of Dental Medicine University of Jordan

Treatment Options for the Compromised Tooth: A Decision Guide

Effect of different endodontic solvents on the effectiveness of two electronic apex locators An in vitro study

Incidence of Apical Crack Initiation during Canal Preparation using Hand Stainless Steel /jp-journals

Restoration of a Grossly Carious tooth using Canal Projection: A Comparative Analysis of different materials for use as Canal Projectors

Limitation of contemporary Endodontic treatment

Effect of Nd:YAG laser irradiation on adherence of retrograde filling materials: evaluation by micro-computed tomography

A Cone-Beam Computed Tomography Outcome Evaluation of Maxillary Posteriors. after Endodontic Microsurgery

Confocal microscopy: A valid approach to evaluate the three-dimensional characteristics of root-end cavities

/jp-journals An in vitro Study to Compare the Effectiveness of F-file with Ultrasonically Activated K-file to Remove Smear Layer

Non-Surgical Endodontic Retreatment after Unsuccessful Apicectomy: A Case Report

Indication for Intentional Replantation of Teeth

Transcription:

Ultrasonic root end cavity preparation assessed by an in situ impression technique Kevin J. Calzonetti, BA; BEd, DDS, Tom Iwanowski, BA, DDS, Dip Endo, a Richard Komorowski, BA, DDS, Dip Endo, b and Shimon Friedman, DMD, c Toronto, Ontario, Canada DEPARTMENT OF ENDODONTICS, FACULTY OF DENTISTRY, UNIVERSITY OF TORONTO Problem. In vitro studies have demonstrated microfractures in resected roots after root end cavity preparation with ultrasonic tips. Such microfractures are of concern; however, they may be artifacts. Objectives. To assess the incidence of microfractures after ultrasonic root end cavity preparation in situ. Study design. Fifty-two roots in two cadavers were endodontically treated, the soft tissues excised, and the root ends exposed and resected. The resected root surfaces were replicated with polyvinylsiloxane impressions. Root end cavities were prepared with ultrasonic tips, then impressed a second time. The roots were retrieved; 25 were processed for direct SEM examination as were both the impressions of each root. The specimens were examined by stereomicroscope and scanning electron microscope. Results. In the impressions, the resected and prepared surfaces appeared irregular, but none demonstrated microfractures. In contrast, 15 retrieved roots showed microfractures. Conclusions. Ultrasonic root end cavity preparation in situ did not cause root microfractures, and the impression technique could be clinically usable with minor modifications. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1998;85:210-5) The management of the root during apical surgery includes apical resection, root end cavity preparation, and usually placement of a root end filling to seal the root canal.1 Until'recently, root end cavity preparation has been performed by means of burs.1 Under restrictive access conditions, bur-prepared cavities may be shallow and misaligned relative to the long axis of the root; consequently, the root end filling may incompletely seal the root canal. 2 Recently, ultrasonic tips have been developed specifically for the purpose of root end cavity preparation. These tips improve the access, alignment, depth, and overall quality of the root end cavity. 2,3 As a result of these improvements, the ultrasonic tips have been widely accepted by clinicians. Several in vitro studies have demonstrated microfractures in the root dentin after root end cavity preparation with ultrasonic tips4-7; however, in another study microfractures were not demonstratedfi All of these studies have been performed in extracted teeth, in which the presence of artifactual microfractures could not be excluded with certainty because of tooth desiccation, brittleness, and the absence of support from periradicular tissues. Because microfractures may increase the chance for apical leakage, 9 their occurrence constitutes a clinical concern. 6 Further investigation is warranted to clarify whether the benefit of root end cavity prepara- aprivate practice, Ottawa, Ontario, Canada. bassistant Professor. Professor and Head, Department of Endodontics. Received for publication June 24, 1997; returned for revision July 29, 1997; accepted for publication Sept. 26, 1997. Copyright 1998 by Mosby, Inc. 1079-2104/98/$5.00 + 0 7/15/87242 tion with ultrasonic tips might not be offset by the risk of inducing root microfractures. To avoid artifactual microfractures, investigation of ultrasonic root end cavity preparation should preferably be performed in situ. Therefore, the purpose of this study was to assess the occurrence of microfractures after root end cavity preparation with ultrasonic tips, in endodontically treated, resected roots in human cadavers. MATERIAL AND METHODS The various steps performed in this study are summarized in Fig. 1. Twenty pairs of contralaterally matched, maxillary and mandibular teeth in two human cadavers were used in this study. A total of 52 roots were radiographed, and access cavities were prepared conventionally. Canals were measured with an apex locator (Root ZX, J. Morita Corp., Kyoto, Japan) and prepared with hand-held files and Gates-Glidden burs. Step-back preparation was performed to at least size 25 at the working length with RC-Prep (Premier, Norristown, Pa.) and copious irrigation with 5.25% sodium hypochlorite. After air drying, the canals were filled with laterally condensed gutta-percha and root canal sealer (Roth 801, Roth International Ltd., Chicago, Ill.). Final radiographs were then exposed (Fig. 2). After 7 days, a circumferential full thickness flap was raised in each jaw, and the entire buccal gingival tissues excised. Access cavities exposing the roots were prepared in the jaws with a no. 6 round bur, and the apical 3 mm of the exposed roots resected with a no. 701 tapered fissure bur (Fig. 3). Both burs were used at 210

ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY Calzonetti et al. 211 Volume 85, Number 2 52 roots; 2 cadavers root canal treatment apical resection I pre-operative[ impression z "'- ~1,~......... : ~ : " ' -- root end cavity preparation post-operativeimpression all retrieved - :: ~, ~ n 0 ~ ] stereomicroscope SEM ~!i2~.~.n~:? ", "i'2211",'/ ] - - - random selected for direct SEM -- 1 ~ l ' ~ o t ~ I control impression I SEM processed for SEM Fig. 1. Flow chart describes method used in this study. Fig. 3. Cadaver mandible with buccal gingivae excised demonstrates access to and resection of root end of first premolar. Fig. 2. Radiograph demonstrates root-filled teeth in human cadaver before apical resection. high-speed with water cooling. The resected root surfaces were wiped with 35% phosphoric acid and airdried. Pre-operative impressions of the resected root surfaces were then obtained with polyvinylsiloxane (Exaflex light and heavy body, GC International Corp., Tokyo, Japan) (Fig. 4), applied by means of customized individual minitrays. The quadrants in the cadavers were divided into two Fig. 4. Ultrasonic tips used for root end cavity preparation. A, AP4-90 tip of the Enac unit. B, CT-1 tip of the Mini-Endo unit. groups; quadrants 1 and 3 in one cadaver, and 2 and 4 in the other were assigned to group 1, and their contralateral quadrants were assigned to group 2. In group 1, root end cavities were prepared with the AP4-90 tip of the Enac ultrasonic unit (Osada Electric Co., Tokyo, Japan), with the intensity adjusted between the "scal-

212 Calzonetti et al. ORAL SURGERYORAL MEDICINE ORAL PATH(SLOGY February 1998 Fig. 5. Photomicrographs of impressions replicating resected surface of endodontically treated root in cadaver. A, Pre-operative impression. B, Impression taken after root end cavity preparation with ultrasonic tip. Note grooves representing "skidding" of ultrasonic tip. There is no evidence of microfracmres. (Original magnification x 20.) ing' I and "vibration" settings. In group 2, root end cavities were prepared with the CT-1 tip of the Mini-Endo ultrasonic unit (Excellence in Endodontics; Fig. 4), with the intensity adjusted to the lowest setting. Each cavity was prepared for 2 minutes with water cooling and slight coronal pressure. All root end cavities were prepared by one operator. Postoperative impressions were taken of the resected and prepared root surfaces repeating the procedure described above. The roots were cut 4 mm from the resected end, retrieved from the jaw with a periodontal curette, placed in 70% alcohol for 48 hours, stained with 1% silver nitrate solution for 10 minutes, and exposed to a high intensity curing light for 30 seconds (Visilux 2, 3M Corp., Minneapolis, Minn.) to allow setting of the silver nitrate solution. The preoperative and postoperative impressions were mounted on aluminum stubs and sputter coated with platinum after critical point drying. Initially, all the impressions and roots were examined under a stereomicroscope (x20), for the presence of microfractures on the resected root surfaces. The impressions were then submitted to further examination with a scanning elec- tron microscope (SEM; x25, 50, 100). For direct observation, a random sample of 25 retrieved roots (11 from group 1 and 14 from group 2) were prepared for SEM as described above. A control impression of the resected surface in these roots was taken with Exaflex in vitro, then prepared for SEM; both the roots and control impressions were examined by'sem. Observations were performed by one investigator (K.C.) in a random, blind sequence. Mann Whitney U test was selected for comparing the incidence of microfractures in the roots for both groups, with a 5% level of significance. RESULTS A representative view of the preoperative and postoperative impressions of a resected root surface is demonstrated in Fig. 5. Stereomicroscopic examination of the impressions clearly identified the root canals and resected surfaces, with minimal interference from smear layer. Bur striations were observed on the dentin surface. The postoperative impressions revealed minor dissimilarities between the two groups, mainly in the form of irregularities and grooves radiating from the canal to the periphery (Fig. 5, B). Microfractures, however, were

ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY CaIzonetri et al. 213 Volume 85, Number 2 Fig. 6. SEMs of impressions replicating resected surfaces, after root end cavity preparation with ultrasonic tips. There are no apparent differences between the two specimens, and no evidence of microfractures in either. A, Root end cavity prepared with AP4-90 tip of the Enac unit; B, Root end cavity prepared with the CT-1 tip of the Mini-Endo unit. (Original magnification x 25.) not observed in any of the impressions. SEM examination of the postoperative impressions provided a better definition of the resected surfaces; however, microfractures were not observed (Fig. 6). In the absence of microfractures in the postoperative impressions in both groups, a statistical analysis was not warranted. Fifteen of the 25 retrieved roots submitted to direct examination by SEM revealed microfractures, 8 from group 1 and 7 from group 2 (Fig. 7, A). These microfractures were consistently identified in the c o n trol impressions of all these roots (Fig. 7, B). DISCUSSION Ultrasonic root end cavity preparation was performed in human cadavers by Wuchenich et al. 3 These authors compared the characteristic appearance of cavities prepared by ultrasonic tips and burs, however, they did not refer to microfractures. All later studies but one 8 have demonstrated microfractures in the roots of extracted teeth in which root end cavities were prepared with ultrasonic tips. 4-7 It is possible that the propagation of the observed microfractures was enabled by the in vitro conditions in which these studies were performed. In the one study in which microfractures did not occur, the pressure on the tip and activation time were restricted, and the teeth were single rooted with considerable root mass. The authors 8 speculated that the finer roots of the posterior teeth might be more susceptible to cracking as a result of ultrasonic root end cavity preparation. In contrast to the previous studies, our study attempted to assess the risk of microfractures in situ. The absence of microfractures in all 52 roots, including those of the molars, suggested that in situ, the periradicular tissues supporting the roots may have absorbed some of the ultrasonic impact and prevented the propagation of microfractures. Performing the study in cadavers also circumvented the tooth desiccation and brittleness associated with work in vitro and thus reduced the chance for artifacts. Exaflex impressions were used to replicate the resected root surfaces in this study. Replicas have been widely used in SEM studies of teeth because the processing for direct examination of tooth structure by SEM is associated with artifactual cracking that may cause misinterpretation of results. 1,tl Such artifacts were indeed present in the retrieved roots processed for direct exam-

214 Calzonetti et al. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY February 1998 Fig. 7. SEMs of resected surface of retrieved root. A, Direct view of surface demonstrates artifactual microfractures. B, View of control impression of root surface in A. Microfractures seen in A are clearly evident, confirming accuracy of impression technique. (Original magnification x 50). ination by SEM; in the absence of the impressions, microfractures found in roots directly examined by SEM could have been erroneously attributed to the root end cavity preparation. Replicas have been applied in several studies on ultrasonic root end cavity preparation. 6,8,12 In these studies, "positive" replicas were produced by pouring resin over the impression. In contrast, in our study "positive" replicas were not prepared because the "negative" impressions are sufficient to observe structural changes in the examined specimens.lo,13 The accuracy of the Exaflex impressions was confirmed by the consistent replication in the control impressions of the microfractures observed in 15 retrieved roots processed for direct examination by SEM. An additional advantage of the impression replication technique is the ability to directly compare the root surfaces before and after root end cavity preparation, 6 and thus to differentiate preoperative and postoperative microfractures. The impression technique used in this study could also be used to replicate the surfaces of resected roots in a clinical setting. Application of this method in a clinical study could potentially yield more clinically rele- vant results. Most importantly, a long-term follow-up of teeth demonstrating microfractures could provide information about the possible influence that such microfractures might have on the treatment outcome of apical surgery. For clinical application, however, a faster setting impression material would be required. From the previous studies it appears that the incidence of microfractures depends on the intensity and duration of the ultrasonic vibration. 4,5,8 In our study, powerful ultrasonic units were applied with low to moderate vibration intensity for a period of 2 minutes. These parameters did not form microfractures; this corroborates the recent findings of Waplington et al. s These results suggest that performing ultrasonic root end cavity preparation at low to moderate intensity for 2 minutes minimizes the risk of root dentin microfractures. In conclusion, under the conditions of this study, including the ultrasonic units, tips, vibration intensities, and cadavers, ultrasonic root end cavity preparation did not cause root dentin microfractures in endodontically treated resected roots. The impression technique used in this study could be usable clinically with minor modifications.

ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY Volume 85, Number 2 We are thankful for the assistance from Robert Chernecky (SEM analysis), Rita Bauer and Steve Burany (photography), and Annemarie Polis (manuscript). REFERENCES 1. Gutmann JL, Harrison JW. Surgical endodontics. Boston: Blaekwell Scientific Publications; 1991. p. 216-30. 2. Cart GB. Surgical endodontics. In: Cohen S, Burns RC, editors. Pathways of the pulp. St. Louis: CV Mosby Co; 1994. p. 546-52. 3. Wuchenich G, Meadows D, Torabinejad M. A comparison between two root-end preparation techniques in human cadavers. J Endodon 1994;20:279-82. 4. Layton CA, Marshall JG, Morgan LA, Baumgartner JC. Evaluation of cracks associated with ultrasonic root-end preparation. J Endodon 1996;24:157-60. 5. Frank RJ, Antrim DD, Bakland LK. The effect of cavity preparations of the root apexes. Endod Dent Traumatol 1996;12:100-3. 6. Abedi HR, Van Merlo BL, Wilder-Smith P, Torabinejad M. Effects of ultrasonic root-end cavity preparation on the root apex. Oral Surg Oral Med Oral Path 1995;80:207-13. 7. Beling KL, Marshall JG, Morgan LA, Banmgartner JC. Evaluation for cracks associated with ultrasonic root-end preparation of gutta-percha filled canals. J Endodon 1997;23:323-6. Calzonetti et ai. 215 8. Waplington M, Lumley PJ, Walmsley AD. Incidence of root face alteration after ultrasonic cavity preparation. Oral Surg Oral Med Oral Path 1997;83:387-92. 9. Saunders WE Saunders EM, Gutmann JL. Ultrasonic root-end preparation. Part 2. Microleakage of EBA root-end fillings. Int Endod J 1994;27:325-9. 10. Sela M, Sela J, Arad T, Ulmansky M. Adaptation of silicate and adaptic to the margins of cavities: a scanning electron miroscopic study. J Oral Rehabil 1975;2:117-24. 11. Crang RFE, Klomparens KL. Artifacts in biological electron microscopy. New York: Plenum Press; 1988. p. 107-29. 12. Van Merlo BL, Abedi HR, Torabinejad M. Preparation of root end resin replicas for SEM examination [abstract RS38]. J Endodon 1995;21:224. 13. Stabholz A, Shani J, Friedman S, Abed J. Marginal adaptation of retrograde fillings and its correlation with sealability. J Endodon 1985;11:218-23. Reprint requests: S. Friedman, DMD Department of Endodontics University of Toronto 124 Edward St. Toronto, Ontario, Canada M5G 1G6 AVAILABILITY OF JOURNAL BACK ISSUES As a service to our subscribers, copies of back issues of Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontics for the preceding 5 years are maintained and are available for purchase from the publisher, Mosby, at a cost of $12.00 per issue until inventor is depleted. The following quantity discounts are available: 25% off on quantities of 12 to 23, and one third off on quantities of 24 or more. Please write to Mosby, Inc., Subscription Services, 11830 Westline Industrial Drive, St. Louis, MO 63146-3318, or call (800)453-4351 or (314)453-4351 for information on availability of particular issues. If unavailable from the publisher, photocopies of complete issues are available from UMI, 300 N. Zeeb Rd., Ann Arbor, MI 48106 (313)761-4700.