Nonin Medical OEM Pulse Oximetry Solutions. Superior Performance for Challenging Patient Conditions

Similar documents
Trust Nonin Oximeters, Even For Your Sickest Patients

Too Good to be True? Three Ways Cheap Pulse Oximeters Could be Short-changing Your Patients and Profits

SenSmart. Universal Oximeter System W: E: T: F:

The first oximetry system to put regional oximetry, pulse oximetry and ease of use at your fingertips.

SenSmart Model X-100. The first oximetry system to put regional oximetry, pulse oximetry and ease of use at your fingertips.

By utilizing VirtuOx IDTF and our VPOD line of Overnight Pulse Oximeters your center will:

All motion is not created equal.

Choosing Mindray SpO2

Automated Blood Pressure Monitor

When Cyanosis is the Norm. Steven M. Schwartz, MD, FRCPC Cardiac Critical Care Medicine The Hospital for Sick Children Toronto

ALCO Regulations. Protocol pg. 47

Testing Masimo rainbow Technology with vpad-a1 1. Background

Infinity MCable -Masimo SET

Spirodoc. 3D Laboratory for respiratory analysis two functional modes: doctor and patient. Four devices in one. Spirometer with Touch Screen display

Oxygen Saturation Monitors & Pulse Oximetry. D. J. McMahon rev cewood

GE Healthcare. Ohmeda TruSat For wherever your patients take you

Measuring Heart Rate and Blood Oxygen Levels for Portable and Wearable Devices

Pulse Oximetry Test: Summary Report

Dr. D.McG.Clarkson Determining the Accuracy of SpO2 Values

TECHNOLOGY - INNOVATION IN ULTRASONIC RESPIRATORY DIAGNOSTICS. Otthon. Ultrasonic handheld spirometer

STAY IN CHARGE STAY IN THE MOMENT

Assessing Global Patient Status with the Halo Index

Pulse Oximeter Accuracy Study

ihealth PO3 Fingertip Pulse Oximeter OPERATION GUIDE INDEX

SUBJECT INFORMATION AND CONSENT FORM

Phonak Fast Facts. Audéo B-Direct

Pulse Oximeter Accuracy Study

Connected to my Health

Defibrillators TEC-8300K series. It s all seamless

Introducing the WatchPAT 200 # 1 Home Sleep Study Device

FloTrac Sensor and Edwards PreSep Central Venous Oximetry Catheter Case Presentations

SENSATION and CS300 Smaller meets faster. IABP System

Where experience connects with innovation

STAY IN CHARGE STAY IN THE MOMENT

Global Pulse Oximetry Market: Trends and Opportunities ( )

X Series Extensive Capabilities

Up to 50% of continuous flow oxygen therapy patients experience clinically significant nocturnal desaturation. 1

Contour Your Body Quickly and Comfortably!

pulse oximetry sensors 2007

Parts Catalog Issued: May 12, Pulse Oximetry Equipment

Appendix E Choose the sign or symptom that best indicates severe respiratory distress.

Company_Brochure_A5_ver1734.

Sleep diagnostics systems

InBody R20 Body composition Analyzer

Make a Smart IT & BT Devices for Future Warning for Heart Failure, Hypoglycemia, and Hyperglycemia Smart Watch. LP Lab LP Watch

MedStar Health considers Continuous Home Pulse Oximetry medically necessary for the following indications:

SOMNOcheck micro CARDIO. Simple Assessment of Cardiovascular Risk During Sleep. In sleep medicine In internal medicine In preventive medicine

61% SvO 2. Clarity. Simplified.

Edwards FloTrac Sensor & Performance Assessments of the FloTrac Sensor and Vigileo Monitor

INVOS System Inservice Guide for Pediatric Use. INVOS System Inservice Guide for Pediatric Use

Journal of Faculty of Engineering & Technology DESIGN AND IMPLEMENTATION OF A WEARABLE HEALTH DEVICE

VITAL SIGNS MONITORING. RVS-100/200 ri-vital. Vital Signs Patient Monitors

MasterScope Body. Powered by SentrySuite

Appendix D An unresponsive patient with shallow, gasping breaths at a rate of six per minute requires:

How Does Pulse Oximetry Work? SpO2 Sensors Absorption at the Sensor Site Oxyhemoglobin Dissociation Curve

Calibration Standards

Χρήση έξυπνων τεχνολογιών στην ανίχνευση κολπικής μαρμαρυγής Use of smart technology in atrial fibrillation detection

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

TABLE OF CONTENTS. Physician's Manual. I. Device Description 2. II. Intended Use 5. III. Contraindications 5. IV. Warnings and Precautions 5

Surgical Monitoring Mouse and Rat Made Easy

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the PreSep oximetry catheter for

Media kit. Highly Targeted Digital Marketing to Respiratory Care and Sleep Medicine Professionals

Professional body composition analysis: BODYSTAT I500 THE SCIENCE BEHIND CLINICAL BODY ASSESSMENT.

Oximeters. Hsiao-Lung Chan, Ph.D. Dept Electrical Engineering Chang Gung University, Taiwan

Chandra Ramamoorthy MBBS; FRCA (UK) Professor of Anesthesiology, Stanford University. Director of Pediatric Cardiac Anesthesiology

CONTINUOUS GLUCOSE MONITORING SOLUTIONS Provided by Roche Diabetes Care

Downloaded from UvA-DARE, the institutional repository of the University of Amsterdam (UvA)

MagPro by MagVenture. Versatility in Magnetic Stimulation

Care that makes sense Designing assistive personalized healthcare with ubiquitous sensing

Enhanced care for your patients. A holistic approach to therapy management reporting

The Most Outstanding Features & Benefits of Today s Auditory Evoked Potentials (AEP) Systems

OPENING UP A NEW WORLD

Dräger Alcotest 6820 Alcohol Screening Device

Icon specifications. Handpiece compatibility

Cogent 2-in-1 Hemodynamic Monitoring System

Performance. Connectivity. Comfort. A Breath of Innovation

CMS-50E Instructions by Cooper Medical Supplies (These instructions are to supplement the manufacturer s user manual not to replace it!

61% SvO 2. Clarity. Simplified.

Aer ODE B3-20. Database System for GEX B3 Dosimetry. Aérial. Optical Dosimetry Equipment. (gamma and/or electron beam versions)

Authorship Abstract Acknowledgements Table of Figures Table of Tables Abbreviations Introduction...

Dräger Mobile Printer

Case study: Non-invasive core body temperature measurements during sleep and daily life with greenteg gskin BodyTemp KIT.

Quick guide to connectivity and the ReSound Smart 3D app

Graft Delivery Devices

Bio-logic AuDX PRO FLEX Quick start Quick start guide

Competitive Intelligence Report Technology & Patents

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the PreSep oximetry catheter for

For personal use only

DRG STIMULATION FOR CHRONIC PAIN FOCUS ON YOUR LIFE NOT YOUR PAIN

QUICK START GUIDE SENTIERO HANDHELD OAE AND AUDIOMETRY SCREENER (GREEN LABEL)

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

Over view. Wrist Placement.

DESIGNING SMART MEDICAL DEVICES WITH FORCE SENSING TECHNOLOGY

MagPro by MagVenture. Versatility in Magnetic Stimulation

Thermo Scientific Finnpipette Manual Pipetting Systems. you can handle. anything

TSV BellaTek Laboratory Solutions. Optimization By Design

The Connected Ear. Life sounds brilliant. The new Pure 13 BT hearing aids. World-class hearing with direct connectivity to iphone and TV.

Hand of Hope. For hand rehabilitation. Member of Vincent Medical Holdings Limited

Exercise Testing Interpretation in the Congenital Heart.

Transcription:

Nonin Medical OEM Pulse Oximetry Solutions Superior Performance for Challenging Patient Conditions

COPD patients often present with complex co-morbidities When treating patients with Chronic Obstructive Pulmonary Disease (COPD), making the right decision is often dependent on getting an accurate oxygen saturation (SpO 2 ) reading. Getting accurate readings can be more difficult in COPD patients with cardiovascular co-morbidities, such as congestive heart failure (CHF). Up to 27% of COPD patients may also have congestive heart failure 1 COPD 27% CHF COPD patients with CHF can challenge oximeter accuracy Poor blood circulation Poor blood circulation is a symptom of CHF 2 and can result in low pulse strength. Low pulse strength can cause inaccurate oximeter readings. Drops in oxygen levels (desaturation) COPD patients have little or no oxygen reserve capacity in their lungs and can be living on the edge of hypoxemia. 3 Many oximeters average measurements over numerous pulses, resulting in a delayed or inaccurate reading during desaturation events. Trust Nonin Medical s PureSAT technology for accurate results in challenging conditions. 1 PHC4-provided hospital discharges between Oct 1, 2007 and Sept 30, 2008. Pittsburgh Regional Health Initiative 2010. 2 Mechanisms of Disease: Congestive Heart Failure. Loyola University Medical Education Network. http://www.meddean.luc.edu/lumen/meded/mech/cases/case4/chf.htm 3 Wild Iris Medical Education, Case Manager CEU, www.nursingceu.com Chronic Obstructive Pulmonary

Superior technology for challenging conditions including rapid SpO 2 changes, poor peripheral blood circulation and motion The inventor Nonin developed finger pulse oximetry and has over 25 years of clinical experience. Peer-reviewed accuracy, FDA-cleared The accuracy and performance of Nonin PureSAT technology is supported by published, peer-reviewed clinical studies. U.S. military certified* The only finger pulse oximeter that has airworthiness approval for use in military aircraft. PureSAT SpO 2 technology The only oximeter with pulse-by-pulse filtering Nonin Medical s clinically proven PureSAT technology utilizes intelligent pulse-by-pulse filtering to provide fast, precise oximetry measurements even in the presence of SpO 2 changes, poor peripheral blood circulation, motion and other challenging conditions. PureLight sensor technology Only the purest red and infrared sensors Nonin s PureLight LEDs hold a steady calibration curve, even at SpO 2 levels below 80% where reliable information is even more critical. Superior accuracy during patient motion In a study comparing accuracy in motion, Nonin and a competitor s finger pulse oximeter were tested during motion and compared to arterial blood gas samples. 4 Control (Blood Gas) Nonin Competitor 97.3% 99% 90% (False Low) 92.8% 93% No Value 86.2% 89% 99% 71.6% 73% 96% Only Nonin s oximeter technology reads accurately during patient motion. The competitor oximeter gave false low and false high SpO 2 readings and was unable to consistently read during patient movement (e.g., extend, flex, twitch, shake, clench, etc.). *Onyx 9500 and Onyx II 9550 finger pulse oximeters are approved for airworthiness in U.S. military aeromedical aircraft. 4 Study conducted in a leading hypoxia research lab. Competitor finger pulse oximeter manufactured by Beijing Choice Electronic Technology Co., LTD. This test is a competitive comparison. There are currently no finger pulse oximeters with accuracy in motion claims cleared by the FDA. Nonin Medical, Inc. Data on file.

Nonin PureSAT Technology accuracy Only Nonin s PureSAT was able to track the subject s desaturation 5 SpO 2 (%) Values 100 95 90 85 80 95 95 82 81 Nonin Control Onyx 6 Nellcor Nonin PureSAT Oximeter A Oximeter B 75 :10 :20 :30 :40 :50 :60 :70 :75 :80 :85 :90 :95 Seconds SpO 2 saturation values you can trust In the above comparison, Nonin oximetry with PureSAT was the only pulse oximeter to accurately track the subject s desaturation down to 81-82% and back up to 96% SpO 2. The two competitors registered changes of only 3% SpO 2. Accuracy in low perfusion The removal of noise artifact is critical to an oximeter s ability to accurately assess SpO 2 in low perfusion. PureSAT employs powerful filtering to achieve dependable, proven accuracy in low perfusion. Patients with thick fingers or dark skin tone or with low perfusion can challenge an oximeter s ability to locate the true pulse and the accurate SpO 2. Pulse input into purification filter Pulse output from purification filter 5 Nonin Medical, Inc. Data on file. 6 Control is Nellcor Tabletop Oximeter

in challenging patient conditions Accurate readings in challenging patient conditions 7 Accuracy is not degraded due to dark skin pigmentation or thick fingers. Nonin SpO 2 Pulse Strength Indicator PureSAT SpO 2 Technology Competitor SpO 2 Technology Perfusion level 0.70 Green P P Perfusion level 0.60 Green P No reading Perfusion level 0.50 Green P No reading Perfusion level 0.40 Green P No reading Perfusion level 0.30 Yellow P No reading Perfusion level 0.20 Yellow P No reading Perfusion level 0.11 Yellow P No reading Perfusion level 0.10 Red No reading No reading Nonin Medical s OEM Solutions Nonin s OEM technology solutions provide you with greater flexibility for more applications. Our easy-tointegrate products and dedicated customer support team have helped more than 100 OEM customers bring low power, high accuracy medical devices to market. With more than 2 million Nonin pulse oximeters sold, Nonin s installed base is one of the world s largest in the medical professional and homecare segments. Dedicated Customer and Technical Service Nonin Medical s oximeters are produced in the USA. We have dedicated customer and technical service staff to serve your OEM needs globally from the USA. Customer Service Toll-free phone: (800) 356-8874 (US and Canada only) Phone: +1 763-553-9968 E-mail: customerservice@nonin.com Technical Service Toll-free phone: (800) 356-8874 (US and Canada only) Phone: +1 763-553-9968 E-mail: technicalservice@nonin.com 7 Nonin Medical, Inc. Data on file.

Nonin Medical s OEM Solutions Nonin offers OEM product evaluation kits to help you evaluate how our OEM solutions will work for you. Each development kit includes the OEM product, demonstration software, technical documentation and any additional interface components required to operate the OEM device with your PC. Try one of our development kits to quickly and easily see how Nonin s OEM solutions can meet your monitoring needs. INTERNAL EXTERNAL-WIRED EXTERNAL-WIRELESS OEM III Module Internal OEM Pulse Oximeter Xpod External Pulse Oximeter with Mini-12 or USB Connectors Onyx II, Model 9560 OEM Finger Pulse Oximeter with Bluetooth wireless technology EXTERNAL-WIRELESS EXTERNAL-USB EXTERNAL-WIRELESS NEW! NEW! Nonin 3230 Bluetooth Smart OEM Finger Pulse Oximeter with Bluetooth Smart wireless technology Nonin 3231 USB OEM Finger Pulse Oximeter with USB Connector WristOx 2, Model 3150 OEM OEM Wrist-worn Pulse Oximeter with Bluetooth wireless technology Call your Nonin OEM sales representative today or visit nonin.com/oemsolutions. Nonin Medical, Inc. 13700 1st Avenue North Plymouth, MN 55441-5443 U.S.A. Tel: +1.763.553.9968 800.356.8874 Fax: +1.763.577.5521 E-mail: info@nonin.com OEM Contacts U.S. Sales: Steve Carey, steve.carey@nonin.com International Sales: Joe Nagel, joe.nagle@nonin.com 2015 Nonin Medical, Inc. All trademarks are the property of Nonin Medical, Inc. unless otherwise noted. Bluetooth and the Bluetooth Logo are registered trademarks of Bluetooth SIG, Inc. 10956-001-01 nonin.com