Available Online through (or) IJPBS Volume 2 Issue 4 OCT-DEC Research Article Pharmaceutical Sciences

Similar documents
Development and validation of related substances method for Varenicline and its impurities

Development and validation of stability indicating RP-LC method for estimation of calcium dobesilate in pharmaceutical formulations

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

A simple validated RP-HPLC method for quantification of sumatriptan succinate in bulk and pharmaceutical dosage form

(ACE) inhibitor class that is primarily used in cardiovascular. conditions. Lisinopril was introduced into therapy in the early

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

CHAPTER 2 SIMULTANEOUS DETRMINATION OF ANASTROZOLE AND TEMOZOLOMIDE TEMOZOLOMIDE CAPSULES 20 MG AND ANASTROZOLE TABLETS 1 MG

Journal of Chemical and Pharmaceutical Research

Tentu Nageswara Rao et al. / Int. Res J Pharm. App Sci., 2012; 2(4): 35-40

Development and Validation of a Simultaneous HPLC Method for Quantification of Amlodipine Besylate and Metoprolol Tartrate in Tablets

Stress Degradation Studies And Validation Method For Quantification Of Aprepitent In Formulations By Using RP-HPLC

Isocratic Reversed Phase Liquid Chromatographic Method Validation for the Determination of Cilostazol in Pure and Formulations

A stability indicating RP-HPLC method for simultaneous estimation of darunavir and cobicistat in bulk and tablet dosage form

Sanjog Ramdharane 1, Dr. Vinay Gaitonde 2

Rao and Gowrisankar: Stability-indicating RP-HPLC Method for Pseudoephedrine, Ambroxol and Desloratadine

A Validated Stability Indicating RP-HPLC Method for Simultaneous Estimation of Valsartan and Clinidipine Combined Tablet dosage forms

Development and Validation of Stability Indicating HPLC method for Determination of Eperisone HCL in Bulk and in Formulation

Dhull Rohit, Kumar Sanjay, Jalwal Pawan Department of Chemistry, OPJS Churu, Rajasthan, India

Development and Validation for Simultaneous Estimation of Sitagliptin and Metformin in Pharmaceutical Dosage Form using RP-HPLC Method

Stability indicating RP-HPLC method development and validation of Etizolam and Propranolol hydrochloride in pharmaceutical dosage form

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR ASSAY AND DISSOLUTION OF METOPROLOL SUCCINATE EXTENDED RELEASE TABLETS

World Journal of Pharmaceutical Research

Journal of Chemical and Pharmaceutical Research

AMERICAN JOURNAL OF BIOLOGICAL AND PHARMACEUTICAL RESEARCH

Pelagia Research Library

A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide in Bulk and Pharmaceutical Dosage Forms

Pelagia Research Library

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE

NOVEL RP-HPLC METHOD. B.Lakshmi et a. concentration range KEY INTRODUCTION. Diltiazem is used to. . It works by of contractionn of the. (dilate).

Comparison of conventional HPLC with UPLC method for determination of albuterol sulfate and it s impurities in pharmaceutical formulation

Research and Reviews: Journal of Pharmacy and Pharmaceutical Sciences

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

Journal of Chemical and Pharmaceutical Research, 2017, 9(9): Research Article

Pelagia Research Library

J Pharm Sci Bioscientific Res (4): ISSN NO

Journal of Chemical and Pharmaceutical Research, 2013, 5(1): Research Article

International Journal of Pharma and Bio Sciences

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR ESTIMATION OF LACOSAMIDE IN BULK AND ITS PHARMACEUTICAL FORMULATION

Available online at Scholars Research Library

Ankit et al Journal of Drug Delivery & Therapeutics; 2013, 3(2), Available online at RESEARCH ARTICLE

Method Development and Validation for the Estimation of Saroglitazar in Bulk and Pharmaceutical Dosage Form by RP-HPLC

Volume 6, Issue 1, January February 2011; Article-021

Simultaneous Determination of Halobetasol and Salicylic Acid Related Substances by Reversed Phase High Performance Liquid Chromatographic Method

Volume 2 (6), 2014, Page CODEN (USA)-IJPRUR, e-issn: International Journal of Pharma Research and Health Sciences

IJRPC 2013, 3(2) Nagamallika et al. ISSN: INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND CHEMISTRY

ANALYTICAL TECHNIQUES FOR THE QUALITY OF ANTI- AIDS DRUGS

Sujatha and Pavani et.al. Indian Journal of Research in Pharmacy and Biotechnology ISSN: (Print) ISSN: (Online)

ASSAY AND IMPURITY METHOD FOR DURACOR TABLETS BY HPLC

Research Article. ISSN Available online at 746

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD ESTIMATION OF TOLVAPTAN IN BULK PHARMACEUTICAL FORMULATION

A stability-indicating LC method for the assay estimation of itraconazole in pharmaceutical dosage form

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms

New RP-HPLC Method for the Determination of Fludarabine in Pharmaceutical Dosage Forms

CHAPTER-5. Sumatriptan Succinate

Simultaneous estimation of Metformin HCl and Sitagliptin in drug substance and drug products by RP-HPLC method

SIMULTANEOUS QUANTIFICATION OF TELMISARTAN AND METOPROLOL SUCCINATE IN TABLETS BY LIQUID CHROMATOGRAPHY

Development and Validation of RP-HPLC Method for the Simultaneous Estimation of Haloperidol and Trihexyphenidyl in API and Combined Tablet Dosage Form

RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF BACLOFEN IN BULK AND PHARMACEUTICAL DOSAGE FORMS

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Method Development and Validation for Simultaneous Estimation of Atorvastatin and Ezetimibe in Pharmaceutical Dosage Form by HPLC

Abstract. G. D. Patil 1, P. G. Yeole 1, Manisha Puranik 1 and S. J. Wadher 1 *

Reverse Phase HPLC Analysis of Atomoxetine in Pharmaceutical Dosage Forms

A Validated Rp-Hplc Method for the estimation of Milnacipran in Tablet dosage forms

International Journal of Pharma and Bio Sciences DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF STRONTIUM RANELATE IN SACHET

Simple and stability indicating RP-HPLC assay method development and validation lisinopril dihydrate by RP-HPLC in bulk and dosage form

36 J App Pharm Vol. 6; Issue 1: 36-42; January, 2014 Rao et al., 2014

Uttam Prasad Panigrahy 1, A. Sunil Kumar Reddy 2, 3 1 Department of Pharmaceutical Analysis and Quality Assurance, Malla Reddy College of Pharmacy,

Available online Research Article

Development and Validation of a Stability-Indicating HPLC Method for Determination of Voriconazole and Its Related Substances

Development and Validation of a Stability-Indicating HPLC Method for Determination of Voriconazole and Its Related Substances

SIMULTANEOUS ESTIMATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE IN TABLETS BY RP-HPLC METHOD

Pelagia Research Library

Int. Res J Pharm. App Sci., 2012; 2(3):22-28

Available online Research Article

Validated UV Spectrophotometric Method Development And Stability Studies Of Acamprosate Calcium In Bulk And Tablet Dosage Form

RP-HPLC Method Development and Validation of Abacavir Sulphate in Bulk and Tablet Dosage Form

* Corresponding author: Prof. Rama Rao Malla


Int. J. Pharm. Sci. Rev. Res., 30(1), January February 2015; Article No. 32, Pages:

REVERSE PHASE HPLC METHOD FOR THE ANALYSIS OF ALFUZOSIN HYDROCHLORIDE IN PHARMACEUTICAL DOSAGE FORMS

Hyderabad, India. Department of Pharmaceutical Chemistry, Glocal University, Saharanpur, India.

Pankti M. Shah et al, Asian Journal of Pharmaceutical Technology & Innovation, 04 (17); 2016; 07-16

vii LIST OF TABLES TABLE NO DESCRIPTION PAGE 1.1 System Suitability Parameters and Recommendations Acidic and Alkaline Hydrolysis 15

ISSN (Print)

Scholars Research Library. Der Pharmacia Lettre, 2015, 7 (5):44-49 (

Available online Research Article

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS TOLBUTAMIDE IN PURE AND PHARMACEUTICAL FORMULATIONS

S. G. Talele, D. V. Derle. Department of Pharmaceutics, N.D.M.V.P. College of Pharmacy, Nashik, Maharashtra, India

Scholars Research Library

ESTIMATION OF RELATED SUBSTANCES OF FEBUXOSTAT IN BULK & 40/80/120mg TABLETS BY RP-HPLC

Available online at Scholars Research Library

ISSN (Print)

International Journal of Pharmacy and Pharmaceutical Sciences. Research Article

A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ASSAY FOR LERCANIDIPINE HYDROCHLORIDE

ANALYTICAL METHOD DEVELOPMENT AND VALIDATION FOR THE DETERMINATION OF ERLOTINIB HYDROCHLORIDE BULK AND IN PHARMACEUTICAL DOSAGE FORM

International Journal of Applied Pharmaceutical Sciences and Research

A. Prameela Rani*, K.E.Pravallika, P.Ravi, O.Sasivardhan

Simultaneous Estimation of Gemcitabine Hydrochloride and Capecitabine Hydrochloride in Combined Tablet Dosage Form by RP-HPLC Method

VALIDATED RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF DEXAMETHASONE AND GRANISETRON IN COMBINED DOSAGE FORMS

Transcription:

Page247 Research Article Pharmaceutical Sciences ULTRA PERFORMANCE LIQUID CHROMATOGRAPHIC METHOD DEVELOPMENT AND VALIDATION FOR THE QUANTIFICATION OF IMPURITIES AND DEGRADATION PRODUCTS IN THE METOPROLOL SUCCINATE ER TABLETS Sainath Kalisetty * 1,2, T.Sreenivasulu reddy 2, A.Malleswara reddy 1, Dama Venugopala rao 1, MSSN Raju 1, K.Vyas 1 and R.Manikandan 3. 1 Analytical Research and Development, IPDO, Dr.Reddy s Laboratories Ltd.,Hyderabad, India. 2 Department of Chemistry, Sri Krishna Devaraya University, Anantapur, India. 3 Formulation Research and Development, IPDO, Dr.Reddy s Laboratories Ltd., Hyderabad, India. *Corresponding Author Email: sainath_kal@yahoo.com, sainathk@drreddys.com ABSTRACT A novel gradient reverse phase Ultra performance liquid chromatographic (UPLC) method was developed for the quantification of Metoprolol impurities and degradation products in the Metoprolol succinate ER tablets. The method was developed using Aquity BEH C18, 100 X 2.1 mm, 1.7 µm column with mobile phase containing a gradient mixture of solvent A and B. 0.13 SLS in 0.1 phosphoric acid and Acetonitrile in 60:40 v/v ratio was used as solvent A, 0.13 SLS solution and Acetonitrile in 20:80 v/v ratio was used as solvent B. The gradient program (T/B) was set as 0/0, 8/0, 12/40, 16/40 16.5/90, 22/90, 22.5/0 and 28/0 with a flow rate of 0.28 ml/minute. The eluted compounds were monitored at 223 nm and the very good separation achieved for the USP listed Impurities and degradation product Diol impurity. The run time was 28 min with column temperature 25 ºC. Metoprolol succinate ER tablets were subjected to the stress conditions of oxidation, acid, base, hydrolytic, thermal and light degradation. Metoprolol peak did not show any flag in the purity table, thus proved the stabilityindicating nature of the method. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. KEYWORDS Degradation product, Method development, Method validation, and UPLC. 1. INTRODUCTION Metoprolol succinate is a beta blocker [1-3], and chemically it is a (±) 1-(isopropylamino)-3-[p-(2- methoxyethyl) phenoxy]-2-propanol succinate. Metoprolol succinate extended-release tablets [4, 5] are indicated for the treatment of stable, symptomatic heart failure of ischemic, hypertensive, or cardiomyopathic origin. The tablets comprise a multiple unit pellet systems and each pellet acts as a separate drug delivery unit and is designed to deliver Metoprolol continuously over the dosage interval. Metoprolol succinate Extended release tablets are official in the United States pharmacopoeia [6] and there was no impurities and degradation products quantification method in the Tablets USP monograph. Related substances method was given in drug substance monograph and it is not capable to quantify degradation product Diol impurity and the run time for each injection is about 60 minutes. So far to our present knowledge, no UPLC [7] method was available in the literature for the quantification of Metoprolol impurities and degradation products. Sainath Kalisetty * et al

Page248 Attempts were made to develop a simple, rugged, robust and cost effective method [8] with shorter run time. This paper also deals with the validation [9] of the developed UPLC method for the accurate quantification of impurities and degradation products in the Metoprolol succinate ER tablets. Fig.1. Metoprolol succinate Fig.2. USP Related compound A ( A) Fig.3. USP Related compound B ( B)

Page249 Fig.4. USP Related compound C ( C) Fig.5. USP Related compound D ( D) Fig.6. Metoprolol Diol impurity 2. EXPERIMENTAL 2.1. Chemicals and reagents The Liquid chromatographic gradient grade acetonitrile, Sodium lauryl sulphate and orthophasphoric acid were purchased from Merck, Darmstadt, Germany. High purity water was prepared by using Millipore MilliQ Plus water purification system. 2.2. Equipment Waters UPLC PDA system was used and the output signal was monitored and processed using empowers software. 2.3. Chromatographic Conditions The method was developed using Aquity BEH C18, 100 X 2.1 mm, 1.7 µm column with mobile phase containing a gradient mixture of solvent A and B. 0.13 Aqueous Sodium lauryl sulphate solution in 0.1 phosphoric acid was used in Mobile phase. 0.13 SLS solution and Acetonitrile in 60:40 v/v ratio was used as solvent A, 0.13 SLS solution and Acetonitrile in 20:80 v/v ratio was used as solvent B. The gradient program (T/B) was set as 0/0, 8/0, 12/40, 16/40 16.5/90, 22/90, 22.5/0 and 28/0 with a flow rate of 0.28 ml/minute. The run time was 28 min with column temperature 25 o C and injection volume of 1 µl. Solvent A was used as a diluent for the preparation of samples. 2.4. Preparation of Stock Solutions A stock solution of Metoprolol succinate (0.9 mg/ml) was prepared by dissolving appropriate amount of drug in Diluent. Working solution of

Page250 0.0045 mg/ml was prepared from the above stock solution for the impurities quantification. 2.5. Preparation of Sample Solution Metoprolol succinate extended release tablets were taken in to the 500 ml volumetric flask, added about 200 ml of diluent and tablets were disintegrated with help of rotary shaking for about 30 minutes and sonication for 30 minutes. Sample solutions diluted to volume to get test concentration of 1140 ppm. 2.6. Method Validation The proposed method was validated as per ICH guidelines. 2.6.1. Specificity Specificity is the ability of the method to measure the analyte response in the presence of its potential impurities. The stress conditions employed were; Acid, Base, Water, oxidation media, heat, moisture and light. To evaluate the ability of the proposed method to separate degradation products from Metoprolol peak, Peak purity was carried out by using PDA detector. 2.6.2. Precision The precision of the related substances method was verified by injecting six individual preparations of Metoprolol succinate ER tablets test preparation spiked with impurities and degradation product Diol impurity. The intermediate precision of the method was also evaluated using different analyst and different instruments. 2.6.3. Limit of Detection (LOD) and Limit of Quantification (LOQ) The LOD and LOQ values were determined at a signal-to-noise ratio of about 3:1 and 10:1 respectively, by injecting a series of dilute impurity solutions. Precision study was carried out at the LOQ level by injecting six individual preparations. 2.6.4. Linearity Linearity test solutions for the related substance method were prepared by diluting stock solutions to the required concentrations. The solutions were prepared at six concentration levels from LOQ to 300 of the 0.1 level. Correlation coefficient value, slope, Y-intercept and bias were calculated. 2.6.5. Accuracy The accuracy study was carried out in triplicate at LOQ, to 300 of the 0.1 concentration level. The percentages of recoveries for impurities were calculated. 2.6.6. Robustness To determine the robustness of the developed method, experimental conditions were deliberately altered. To study the effect of flow rate, flow was changed from 0.25 to 0.31 ml/min. The effect of the column temperature was studied at 20 and 30 C, effect of the percent organic strength was studied by varying acetonitrile composition, 10 and +10 with constant ratio of Buffer. 2.6.7. Solution Stability and Mobile Phase Stability The solution stability of related substance method was carried out by leaving spiked sample solutions in tightly capped volumetric flasks at room temperature for two days. Mobile phase stability was carried out by injecting the freshly prepared sample solutions for two days. 3. RESULTS AND DISCUSSION 3.1. Method Development and Optimization The objective of the Method development was to develop simple, Robust, Rugged stability indicating UPLC method with shortest possible run time. Related substances methods published in the literature have about 60-70 minutes run time for each injection by using HPLC systems. To reduce the run time attempts were made to develop highly sensitive method by using UPLC. Mobile phase composition and Gradient

Page251 programs optimized to achieve very good separation between impurities with lowest possible run time. Method is capable to quantify polar Degradation product, Diol impurity and non polar USP related compound-d within 28 minutes of run time. Fig.7: Blank chromatogram Fig.8: Standard chromatogram Fig.9: Test chromatogram spiked with Impurities

Page252 3.2. Validation of the Method 3.2.1. Specificity All forced degradation samples were analyzed as mentioned in Section 2.6.1 using PDA detector to ensure the homogeneity and purity of Metoprolol. No purity flag was observed in any of the degradation conditions, which indicates the stability indicating nature of the method. Degradation was summarized in Table.1. Stress Condition Table 1: Forced degradation data. Drug Product Peak Purity Purity Angle Purity Threshold Stressed with 2N HCl solution for about 15 Hours at 60 C. 0.051 0.258 NO Stressed with 2N NaOH solution for about 6 Hours at 60 C. 0.040 0.251 NO Stressed with 6 Hydrogen peroxide (H 2 O 2 ) for about 1 Hour at 60 C. 0.121 0.274 NO Stressed with purified water for about 15 hours at 60ºC. 0.043 0.256 NO Exposed to visible light for about 1.2 million Lux. 0.036 0.309 NO Exposed to UV light both for about 200 watt hours/square meter. 0.037 0.309 NO Dry heating done at 105 C for about 6 hrs. 0.067 0.258 NO Exposed to humidity at 25 C, 90 RH for about 7 days 0.036 0.308 NO Purity flag 3.2 2. Precision The R.S.D. for the of Metoprolol Related compounds was less than 2 conforming good precision of the method. Sample No. Metoprolol Impurities Related Diol Compound A Table 2: Method precision data Related Compound B Related Compound D Related Compound D 1 0.18 0.097 0.84 0.101 0.47 0.094 0.60 0.099 2.12 0.093 2 0.18 0.097 0.84 0.100 0.47 0.095 0.60 0.097 2.12 0.093 3 0.18 0.097 0.84 0.100 0.47 0.095 0.60 0.097 2.12 0.093 4 0.18 0.097 0.84 0.100 0.47 0.096 0.60 0.098 2.12 0.094 5 0.18 0.096 0.84 0.100 0.47 0.094 0.60 0.097 2.12 0.093 6 0.18 0.097 0.84 0.101 0.47 0.095 0.60 0.097 2.12 0.093 Average NA 0.097 NA 0.100 NA 0.095 NA 0.098 NA 0.093 RSD NA 0.4 NA 0.5 NA 0.8 NA 0.9 NA 0.4 ; Relative retention time, NA: Not applicable

Page253 3.2.3. Limits of Detection and Quantification Table 3: Limit of Detection and Limit of quantification Name impurity Limit of Detection Metoprolol 0.012 0.039 Diol 0.004 0.012 A 0.010 0.040 B 0.009 0.030 C 0.007 0.024 D 0.006 0.023 Limit of Quantification 3.2.4. Linearity Linear calibration plot for the related substance method was obtained over the calibration ranges tested, i.e. LOQ to 300. The correlation coefficient obtained was about 0.999 and the bias is less than 3. Table 4: Linearity Name Coefficient of correlation (r) Intercept (C) Slope (m) Bias Metoprolol 0.999-54.021 6448.857 0 Diol 0.999 233.184 9171.787 2 Related Compound A 0.999 19.726 8228.573 0 Related Compound B 0.999-6.299 7852.968 0 Related Compound - C 0.999 48.238 9355.657 0 Related Compound D 0.999 30.341 8319.888 0 3.2.5. Accuracy The percentage recoveries of impurities are well within the limits of 85 to 115 at LOQ, and at 300 level. Recovery values for impurities are presented in table. Table 5: Accuracy Name of the Spike level Mean Recovery Diol Related Compound A Related Compound B Related Compound C Related Compound D At LOQ 94.9 At 300 92.0 At LOQ 97.7 At 300 95.5 At LOQ 91.1 At 300 90.8 At LOQ 96.8 At 300 95.1 At LOQ 91.2 At 300 91.3

Page254 3.2.6. Robustness In all the deliberate varied chromatographic conditions (flow rate, column temperature and composition of organic solvent), the relative retention times are same as that of regular method conditions. This Data illustrates the robustness of the method. Metoprolol Succinate Related Substances Table 6: Flow rate variation Relative Retention time Name 0.25 ml/min 0.28 ml/min 0.31 ml/min Related Compound A 0.84 0.84 0.84 Related Compound B 0.49 0.49 0.48 Related Compound C 0.62 0.61 0.61 Related Compound D 2.02 2.18 2.33 Diol 0.19 0.19 0.19 Metoprolol Succinate Related Substances Name Table 7: Temperature variation Relative Retention time 20 C 25 C 30 C Related Compound A 0.84 0.84 0.84 Related Compound B 0.48 0.48 0.48 Related Compound C 0.61 0.61 0.61 Related Compound D 2.10 2.14 2.19 Diol 0.18 0.19 0.19 Metoprolol Succinate Related Substances Name Table 8: Organic composition variation Relative Retention time 90 100 110 Related Compound A 0.84 0.84 0.84 Related Compound B 0.48 0.48 0.48 Related Compound C 0.61 0.61 0.61 Related Compound D 2.17 2.14 2.13 Diol 0.19 0.19 0.19 3.2.7. Solution Stability and Mobile Phase stability No significant changes were observed in the content of impurities during solution stability and mobile phase stability experiments. Sample solutions and mobile phases used during the related substance determination were stable for 2 days. 4. CONCLUSIONS The gradient UPLC method developed for the quantification of Metoprolol impurities and degradation products is precise, accurate, linear,

Page255 robust, rugged and specific. Satisfactory results were obtained from validation of the method. The method is stability-indicating and can be used for routine analysis of production samples and Stability samples. 5. ACKNOWLEDGEMENTS The authors wish to thank the management of Dr.Reddy s laboratories Ltd, for supporting this work. The authors wish to acknowledge the Formulation R&D Group for providing the samples for research work. REFERENCES 1. Falkner B, Francos G, Kushner H, Metoprolol succinate, a selective beta-adrenergic blocker, has no effect on insulin sensitivity., J Clin Hypertens (Greenwich). 2006 ;8(5):336-43. 2. Kobalava ZhD, Gudkov KM, Metoprolol CR/XL: advanced formulation of a classical beta-blocker., Kardiologiia, 2003; 43(9):91-100.) 3. Zebrack JS, Munger M, Macgregor J, Lombardi WL, Stoddard GP, Gilbert EM, Beta-receptor selectivity of carvedilol and metoprolol succinate in patients with heart failure (SELECT trial): a randomized dose-ranging trial., harmacotherapy. 2009, 29(8):883-90. 4. Dadarwal SC, Madan S, Agrawal SS, Formulation and evaluation of delayed-onset extended-release tablets of metoprolol tartrate using hydrophilic-swellable polymers., Acta Pharm. 2012, 62(1):105-14. 5. Shah R, Parmar S, Patel H, Pandey S, Shah D., Formulation Development of Metoprolol Succinate and Hydrochlorothiazide Compression Coated Tablets., Curr Drug Deliv. 2012 Sep 26 6. USP, The United States Pharmacopoeia, USP32, US Pharmacopoeial Convention Inc. Rockville, MD, 2009, pp. 2965. 7. Lucie Nováková Ludmila Matysová,Petr Solich; Advantages of application of UPLC in pharmaceutical analysis., Talanta, 2006,68(3); 908 918, 8. Liod R.Snyder,Joseph J.Kirckland,loseph L.Glaich.Practical HPLC Method Development,Second edition,john Wiley & Sons Inc,United states of America,1997,1-265. 9. ICH: Q2 (R1), Validation of analytical procedures, Text and Methodology (November 2005). *Corresponding Author: Sainath Kalisetty, Analytical Research and Development, IPDO, Dr.Reddy s Laboratories Ltd. Hyderabad, India