Tube Shunts in Advanced Angle Closure Glaucoma: A Pilot Study

Similar documents
Five-year Treatment Outcomes in the Ahmed Baerveldt Comparison (ABC)Study

Humanity s Vision Is Our Focus. The Ahmed Glaucoma Valve

Review of the Ahmed versus Baerveldt study 5-year treatment outcomes

EXP11677SK. Financial Disclosure. None to be Declared EXP11677SK

Mechanics of the Ahmed Glaucoma Valve

Landmark Tube Trials

Managing & Avoiding Post-Op Complications in Tube Surgeries

Plate/Valve Specifications: Thickness: 0.9mm Width: 13.00mm Length: 16.00mm Surface Area: mm 2

Effects of Early Postoperative Intraocular Pressure after Ahmed Glaucoma Valve Implantation on Long-term Surgical Outcomes

STAB INCISION GLAUCOMA SURGERY (SIGS)

STAB INCISION GLAUCOMA SURGERY (SIGS) AMAR AGARWAL

STAB INCISION GLAUCOMA SURGERY (SIGS)

TRABECULECTOMY. Dr. Sandra M. Johnson, MD

Objectives. Tubes, Ties and Videotape: Financial Disclosure. Five Year TVT Results IOP Similar

Trabeculectomy is the most commonly performed surgery

Surgical outcomes of Trab and Tube for Uveitic glaucoma - Experience from a Tertiary Institution

Case Report Combined Scleral Flap with Donor Scleral Patch Graft for Anterior Tube Placement in Glaucoma Drainage Device Surgery

Clinical Study XEN Glaucoma Implant with Mitomycin C 1-Year Follow-Up: Result and Complications

Clinical Study Comparison of the Changes in Corneal Endothelial Cells after Pars Plana and Anterior Chamber Ahmed Valve Implant

WGA. The Global Glaucoma Network

Pre-operative intraocular pressure does not influence outcome of trabeculectomy surgery: a retrospective cohort study

THE CURRENT TREATMENT OF GLAUCOMA IS DIrected

Aqueous Shunts for the Treatment of Glaucoma

Challenging complications of valve implantation. Salah M Al-Mosallamy MD Assistant professor of ophthalmology 2014

Subject Index. Canaloplasty aqueous outflow system evaluation 110, 111 complications 118, 119 historical perspective 109, 110

Comparison of the Outcome of Silicone Ahmed Glaucoma Valve Implantation with a Surface Area between 96 and 184 mm 2 in Adult Eyes

Aqueous Shunts and Stents for Glaucoma. (90321) (Formerly Aqueous Shunts for Glaucoma)

Observation of curative effects of Ex-PRESS and AGV implantation in the treatment of refractory glaucoma

Anterior segment imaging

EX-PRESS Glaucoma Filtration Device Surgical Procedure

Beginner (score = 3) Can hold goniolens but hesitates to move to visualize a different angle.

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE

Developments in Glaucoma Surgery

Trabeculectomy A Review and 2 Year Follow Up

Trabeculectomy combined with cataract extraction: a follow-up study

AC & ACG Instruction Course Surgical Treatments for PACG

MEDICAL POLICY. SUBJECT: AQUEOUS DRAINAGE DEVICES (STENTS AND SHUNTS) POLICY NUMBER: CATEGORY: Technology Assessment

Optometric Postoperative Cataract Surgery Management

Basic microsurgical suturing techniques for beginners

Aqueous Shunts and Stents for Glaucoma

Management of Angle Closure Glaucoma Hospital Authority Convention 18 May 2015

STUDY OF EFFECTIVENESS OF LENS EXTRACTION AND PCIOL IMPLANTATION IN PRIMARY ANGLE CLOSURE GLAUCOMA Sudhakar Rao P 1, K. Revathy 2, T.

The second leading cause of blindness in the world is

TRABECULECTOMY THE BEST AND WORST CANDIDATES

Corporate Medical Policy

MIGS Rapid Fire Outline 1 st talk: Goniotomy, Lisa Young, OD, FAAO

Trabeculectomy with ologen implant versus trabeculectomy with mitomycin-c in primary open angle glaucoma: A 2-year study

Repositioning a glaucoma drainage device tube from the anterior chamber to the ciliary

EFFICACY AND SAFETY OF CANALOPLASTY IN SAUDI PATIENTS WITH UNCONTROLLED OPEN ANGLE GLAUCOMA

Cronicon EC OPHTHALMOLOGY. Research Article Trephine Assisted Trabeculectomy Technique. Idrees* Introduction

Implants in glaucoma: a minor review

AHMED AND BAERVELDT GLAUCOMA DRAINAGE IMPLANTS: LONG-TERM RESULTS AND FACTORS INFLUENCING OUTCOME JACOB J., STALMANS I., ZEYEN T.

Highlights On The Management Of Phacomorphic Glaucoma

Changes of corneal endothelial cell density after EX-PRESS Glaucoma shunt implantation: 2-year follow-up study.

Glaucoma Surgical Treatments. Murray Fingeret, OD Justin Schweitzer, OD Joe Sowka, OD

Outcomes of Ex-PRESS and Trabeculectomy in a Glaucoma Population of African Origin: One Year Results

Combined phacoemulsification and Ahmed valve glaucoma drainage implant: A retrospective case series

MEDICAL POLICY. SUBJECT: AQUEOUS DRAINAGE DEVICES (STENTS AND SHUNTS) POLICY NUMBER: CATEGORY: Technology Assessment

These devices, when FDA approved, are covered for patients with glaucoma that is not adequately controlled with medical therapy.

Romanian Journal of Ophthalmology, Volume 59, Issue 4, October-December pp:

Morning Report. copyright The University of Colorado. Ashley Laing 09/01/10 Preceptor- Dr. Pantcheva

Case Report Managing Drawbacks in Unconventional Successful Glaucoma Surgery: A Case Report of Stent Exposure

Partial Tenon s capsule resection with adjunctive mitomycin C in Ahmed glaucoma valve implant surgery

Aqueous Shunts and Stents for Glaucoma

Surgical Outcomes of Ahmed or Baerveldt Tube Shunt Implantation for medically Uncontrolled Traumatic Glaucoma

PRESENTED By DR. FAISAL ALMOBARAK, MD

Third Generation. Glaucoma Drainage Device

Surgical outcome of phacoemulsification combined with the Pearce trabeculect~m~ in patients with glaucoma

A retrospective review of autologous scleral flap versus donor scleral graft

GLAUCOMA SURGERY: FROM THEN TIL NOW (COPE Course ID: GL)

CLINICAL SCIENCES. Trabeculectomy With Releasable Sutures. development, trabeculectomy

3/16/2018. Ultrasound Biomicroscopy in Glaucoma By Ahmed Salah Abdel Rehim. Prof. of Ophthalmology Al-Azhar University

Choroidal detachment following retinal detachment surgery: An analysis and a new hypothesis to minimize its occurrence in high-risk cases

CLINICAL SCIENCES. Conjunctival Advancement for Late-Onset Filtering Bleb Leaks

Factors Associated with Outcomes of Combined Phacoemulsification and Ahmed Glaucoma Valve Implantation

sad EFFECTIVE DATE: POLICY LAST UPDATED:

Glaucoma drainage device surgery in children and adults: a comparative study of outcomes and complications

Aqueous Shunts and Stents for Glaucoma

XEN GEL STENT MIGS 4/5/2018 OMAHA AND LINCOLN EYE AND LASER INSTITUTES XEN45 GEL STENT WHY ARE WE LOOKING FOR NEW INNOVATIONS IN GLAUCOMA SURGERY?

Russ Trenary President & CEO.

Third Generation. Glaucoma Drainage Device

Long-term results of Ahmed glaucoma valve and Molteno implant in neovascular glaucoma

Inaccuracy of Intraocular Lens Power Prediction for Cataract Surgery in Angle-Closure Glaucoma

MATERIALS AND METHODS

INTRODUCTION J. DAWCZYNSKI, E. KOENIGSDOERFFER, R. AUGSTEN, J. STROBEL. Department of Ophthalmology, University Hospital Jena, Jena - Germany

Glaucoma is the second leading cause of blindness

Pterygium Excision and Conjunctival-Limbal Autograft Transplantation: A Simplified Technique

Aqueous Shunts and Stents for Glaucoma

Trabeculectomy - A Short Term Follow-up

Clinical Study Results of Combined Cyclectomy/Trabeculectomy Procedure Compared with Ahmed Glaucoma Valve Implant in Neovascular Glaucoma Cases

CATARACT SURGERY IN UVEITIS. Professor Harminder Singh Dua

Transient Intraocular Pressure Elevation after Trabeculotomy and its Occurrence with Phacoemulsification and Intraocular Lens Implantation

Implants for draining neovascular glaucoma

Intraocular Pressure Control after Implantation of an Ahmed Glaucoma Valve in Eyes with a Failed Trabeculectomy

9/25/2017 CASE. 67 years old On 2 topical meds since 3 years. Rx: +3.0 RE LE

Post- Penetrating Keratoplasty Glaucoma

PRECISION PROGRAM. Injection Technique Quick-Reference Guide. Companion booklet for the Video Guide to Injection Technique

CLINICAL SCIENCES. Complications of Baerveldt Glaucoma Drainage Implants. such as the Baerveldt implant are used in the surgical

Transcription:

Tube Shunts in Advanced Angle Closure Glaucoma: A Pilot Study Kirti Singh, Divya Jain, Manav Sachdev, Sumit Grover Guru Nanak Eye Centre, Maulana Azad Medical College, India Abstract Purpose: To evaluate efficacy and safety of tube shunts in advanced angle closure glaucoma Vs. Standard Trabeculectomy. Method: Fifteen cases of end stage angle closure glaucoma with visual acuity ranging from hand movements only to perception of light were implanted with pediatric model Ahmed glaucoma valve (AGV). The efficacy and complications (if any) of the implant group were evaluated in comparison to a control group of fifteen patients of similar profile with angle closure glaucoma subjected to trabeculectomy with releasable sutures. Both group cases were followed up over a 12 month period. Results: Tube shunts were as effective as trabeculectomy in the early postoperative period of 4 months with increased complications like corneal edema and mild hyphema. Over a 1 year follow up tube related complications like tube erosion and retraction were noted with reduced efficacy of the shunt versus trabeculectomy at complete success of 66% and 80 % respectively. The tube shunt surgery was performed with three modifications from conventional method due to the angle closure element. Conclusions: Tube implants should not be attempted as primary surgical means in chronic angle closure glaucoma without considering certain surgical modifications and precautions. Standard Trabeculectomy remains gold standard primary procedure in this subtype of glaucoma. Keywords: ahmed glaucoma valve, pediatric sized implant, end stage chronic angle closure glaucoma, surgical modifications, trabeculectomy Introduction Trabeculectomy is the standard surgical procedure for managing uncontrolled glaucoma patients but has not stood the test of time as a fool proof procedure. The associated complications such as shallow chamber, bleb leaks, bleb infections, and bleb dysesthesia have led to increase in use of tube shunts or glaucoma drainage devices as an alternative to trabeculectomy. 1,2 Glaucoma drainage devices (GDD) have been conventionally used as secondary procedures in cases with prior failed glaucoma filtration surgeries. In refractory glaucomas like neovascular or post uveitic glaucoma, where the chances of failure of trabeculectomy are high, these devices have been implanted as a primary procedure. Recent studies have demonstrated comparable success of tube shunts versus trabeculectomy and laid the path for expanding indications of tubes. The Tube Vs Trabeculectomy (TVT) study 3 was one such study which showed a comparable intraocular pressure reduction of 49.5% in Trabeculectomy and MMC group and 49.9% decrease in IOP in tube group at both 1 year and 3 year follow up. Conventionally tubes have been implanted in cases with open angle glaucoma or in cases with roomy chambers where the natural lens has been replaced with an IOL. In conditions with shallow anterior chamber configuration, Quick Response Code Access this article online Website DOI http://dx.doi.org/10.7869/djo.239 like various subtypes of angle closure glaucoma, tube placement is perceived to be difficult. In an Asian country like India, with a large proportion of glaucoma population being constituted by angle closure glaucoma (ACG) cases with comparatively shallow anterior chamber depth tube placement in anterior chamber is difficult and increases risk of tube corneal touch postoperatively. The smaller ocular dimensions of angle closure eyes presumably can lead to increased risk of plate exposure and implant extrusion. There is paucity of data to evaluate the role of GDDs in angle closure glaucoma in literature. Therefore, this pilot study was undertaken to evaluate efficacy and safety of Ahmed glaucoma valves in comparison to conventional trabeculectomy in patients of end stage angle closure glaucoma, a common subtype of recalcitrant glaucoma in south east Asia. Material and Methods Thirty eyes of thirty patients with end stage angle closure glaucoma, uncontrolled intraocular pressure and vision of either perception of light, and/or inaccurate projection of rays were scheduled for tube implant or trabeculectomy surgery. The inclusion criteria followed were cases with high IOP >25 mm Hg, uncontrolled on at least two anti-glaucoma drugs. All cases had documented synechial angle closure of >180 degrees, despite patent peripheral iridotomy. For ethical reasons, only patients with poor preoperative vision were included in AGV group (study group). In addition, only patients with visual acuity of > 6/60 (Log Mar 1.0) in the fellow eye were included in the study. Cases with severe dry eyes (Schirmer < 3 mm), corneal edema and/or central AC depth of less than 1.8 mm were excluded. The study was conducted after obtaining ethical approval as per Helsinki guidelines. Informed consent was taken from all patients. In the study group (tube group) 15 eyes were included in whom AGV pediatric model FP8 was used. This 181

E-ISSN 2454-2784 Original Article modification was done as prior experience in using adult model FP7 resulted in difficulties during insertion of plate in the shallow fornices of these patients and led to subsequent tube migration. The surface area of FP 8 model being 96 mm 2 compared to much larger area of 184 mm 2 in FP 7 lend itself more suitable to placement in these shallow fornices eyes. In the control group (15 eyes) trabeculectomy with MMC with two releasable sutures was performed. Preoperative recording of visual acuity, intraocular pressure, corneal thickness (ultrasonic pachymetry), specular microscopy for corneal endothelial cell count, biometric parameters of anterior chamber depth and axial length was done, in addition to the routine ophthalmic and systemic examination. Postoperative parameters evaluated were slit lamp biomicroscopy for anterior chamber reaction, tube status, bleb morphology, corneal thickness and endothelial cell count, ultrasound biomicroscopy (UBM) to evaluate the bleb and peripheral anterior chamber morphology. Bleb morphology was scored objectively using Migdal and Hitchings classification. 4 Complete surgical success was defined as attaining IOP less than 18 mmhg without medication. Surgical Technique The specifications of the technique of AGV implantation included 3 mm fornix based conjunctival flap with 5-6 mm relaxing incisions, made at the two ends of the limbal peritomy. A rectangular 5 x 5 mm partial thickness scleral flap was hinged at the limbus, in the supero-temporal quadrant. By blunt dissection of tenon s capsule and episcleral tissue, space was created in the superior temporal quadrant between superior and lateral rectus. The valve was primed with sterile solution and the valve body was inserted between the rectus muscles and sutured to the sclera, with 8-0 silk/ monofilament nylon sutures, placed through the eyelets in the body of the AGV. The leading edge of the device was placed at or beyond 8 mm from the limbus. The drainage tube was trimmed to permit 2-3 mm insertion of tube in to the anterior chamber for the initial 4 cases. The tube bevel was cut to face the corneal endothelium and tube was inserted beneath the scleral flap. After a slow paracentesis, the anterior chamber was partly filled with 2% methyl cellulose. The anterior chamber was then entered at the limbus under the flap, with a 23 gauge needle parallel to iris plane. Tube was then inserted through the entry track of the needle with a specialized Ahmed forceps designed for the same. The direction of tube was parallel to iris and away from corneal endothelium. It was anchored to the scleral bed with 2 or 3, 10-0 monofilament nylon sutures. Except for initial two cases a surgical peripheral iridectomy was performed adjacent to the tube to prevent iris bunching as shown in Figure 1. The iridectomy was performed through a clear corneal incision adjacent and anterior to the 23 gauge needle entry site. The exposed drainage tube was covered with the superficial scleral flap which was sutured with two to three, loose 10-0 nylon sutures. The relaxing incisions of the conjunctival flap were sutured with 8-0 monofilament nylon. Anterior chamber was formed with sterile Ringer lactate solution, at end of procedure through the paracentesis site. Figure 1: Iris bunching, arrow showing bunching of iris adjacent to tube bevel. Note the peripheral iridectomy is present away from tube end, which is creating sucking of iris tissue into tube bevel. The ideal length of tube with adjacent peripheral iridectomy (PI) was left at 1.5 mm as shown in Figure 2. Post-operative medications included topical steroid antibiotic combination and cycloplegics for 6 to 8 weeks. Systemic Acetazolamide was prescribed for the first 2-3 days if required. Trabeculectomy with MMC was performed using fornix based flap, subconjunctival application of 0.02% MMC for 2 minutes and application of two releasable sutures using Wilson s technique. 5 Releasable sutures in trabeculectomy group were released between day 7 to day 14 when IOP of >14-16 mmhg was documented or when bleb height was poor. In case of good bleb height and adequate IOP control, the sutures were left in situ till end of first month. after which they were removed. The patients in both groups were followed up on post op day 1, 7, 14, 1 month, 4 months, 6 month and 12 months. The data was entered in MS EXCEL spreadsheet and analysis was done using Statistical Package for Social Sciences (SPSS) version 21.0. Qualitative variables were compared using Fisher s exact test. A p value of <0.05 was considered statistically significant. Figure 2: Only 1.5mm of tube is in AC. Note peripheral iridectomy is touching tube entry site. The clear corneal entry used for creating PI is sutured. No iris bunching is seen. Results The patient profile is tabulated in Table 1. 182

Table 1: Case profile in study and control group Age Tube group Trabeculectomy group Sex 54 + 10.42(Mean + SD) 53 + 9.41(Mean + SD) Eye involved Males 11 Females 4 Pre operative IOP Right 7 Left 8 Males 5 Females 10 Right 6 Left 9 Preoperative ACD 39+9.75 (Mean + SD) 33+9.8(Mean + SD) ( Anterior chamber depth in mm ) 2.50+.42(Mean + SD) 2.58+.39 (Mean + SD) Pre op central corneal thickness mm 509.87+46.22 525.80+43.20 Inflammatory reaction Grade 1-2 on day 1, subsided by day 3 Table 2: Complications seen in postoperative period Tube (15 eyes) 6 eyes 4 eyes Lens swelling 3 eyes* 1 eye Shallow AC 3 1 eye Corneal edema (localized) 3 eyes - Hyphema on day 1 resolved by day 7. 2 eyes / 1 eye Tube retraction 7. 2 eyes 1 within 1 week, second after 6th month required re- surgery Tube erosion 1 eye at 4 month, Required sclera patch graft and resuturing at 9 months Trabeculectomy (15 eyes) NA NA There could be more than one complication in the same case * Two eyes subsequently required lens extraction due to tube touch and high IOP, third patient was managed by AC reformation and IOP normalized by 2 weeks and tube started functioning. / The hyphema resulted in high IOP in tube cases, which was managed conservatively and IOP normalized after resolution of hyphema. = Visual Acuity In AGV group 8 eyes (53.3 %) had visual acuity (VA) of inaccurate projection of rays (PR) or worse, and six eyes (40 %) had VA of accurate projection of rays only. In the trabeculectomy (control) group 10 eyes (66.7%) had VA ranging between 6/60 to 6/36 (LogMar 1.0 to 0.8) preoperatively, the remainder had vision ranging from hand movements to inaccurate projection of rays. This vision was maintained in all cases except three in AGV group, at all follow ups after initial first month. Visual acuity in trabeculectomy patients returned to preoperative levels 1 month after removal of releasable and bleb forming sutures. In the study group the poor vision was maintained in all except three cases. The cause of deterioration in vision was rapid enhancement of cataractous changes that required temporal clear corneal phacoemulsification within 1 month of tube implant and corneal edema in the third despite there being no documented tube corneal touch by either slit lamp biomicroscopy or ultrasound microscopy. Intraocular Pressure (IOP) Mean intra ocular pressure (IOP) preoperatively was 39 mm Hg + 9.7 in tube group and 33 mmhg + 9.8 in trabeculectomy group. Post operatively IOP drop was noted in both groups, with mean IOP at day 1 being 13.40 mmhg + 3.602 in tube group and 6.87+ 6.545 in Trab group. Pressures on post op day 7, 14, 1 month, 4 months, 6 month and 12 months were significantly lower than preoperative values in both the groups which were statistically significant. Figure 3 demonstrates IOP change in both the groups. IOL Drop (mm of Hg) Post op Time Interval Figure 3: IOP drop from preoperative values in both groups on post op day 1, 7, 1 month, 4 months, 6 months and 1 year. 183

E-ISSN 2454-2784 Original Article Complete success (IOP < 18 mmhg) without medication was achieved in 66.7% of cases in AGV group and in 86.7% in Trab group at 4 months (short term follow up). This success was maintained at 6 months in 60% and 86% cases of AGV and Trab respectively. At 6 months one patient of AGV group developed tube retraction requiring surgery with tube expander, and required anti glaucoma medications for a period of 3 weeks. At 1 year, the complete success was stable at 66% and 80 % in AGV and Trab group. Requirement of one or more anti -glaucoma medication was there in 34%.cases of AGV group and about 20% cases of Trabeculectomy group at end of 1 year. This inter group difference did not achieve statistical significance (p value 0.2). Qualified success defined as IOP of < 18 mmhg with 1 topical medication was achieved in 86.7% cases in AGV group and 100% in Trab group at the end of 4 months follow up and persisted till 1 year of follow up. This intergroup difference again did not achieve statistical significance (p value 0.24). The drop in IOP persisted till end of study at 1 year. In three eyes of the AGV group, a hypertensive phase lasting from third to sixth week was noted, with IOP in these patients rising to 20-25 mm Hg necessitating use of topical anti-glaucoma medications for a period of 6-8 weeks. Complications Post surgery pre clinical corneal edema manifested as an increase in central corneal thickness (CCT) was noted in both groups. At the end of 4 months mean CCT was 514.3 + 40.7 μ in AGV group showing an increase of 1.2% and 516.7+ 39.8 μ in Trab group with increase of 1.6%. The difference was not statistically significant by independent sample test. At final follow up of 12 months, no statistically significant difference was noted in CCT in both the groups. Corneal endothelium damage was further confirmed by specular microscopy. Mean specular count decreased from preoperative levels of 2505.8+196.5: 2455.5+166.0 to 2444.9+206.0: 2412.0+159.5 in AGV: Trab group to respectively, the inter group difference being statistically insignificant. Other complications during postoperative period are tabulated in Table 2. Discussion Trabeculectomy with anti-metabolites is the gold standard for glaucoma drainage surgery. However, the nemesis of this surgery is shallow anterior chamber during the early postoperative period and bleb failure leading to attrition in IOP control in the late postoperative period. Tube shunts have been gaining popularity as an alternative surgery with success rates varying from 25% -100% at one year follow up depending on inclusion criteria as shown by previous studies. 6-8 Both valved and non valved tubes have been employed with non valved tubes causing more hypotony and subsequent corneal complications. 9-11 Present study done using a valved implant in chronic angle closure glaucoma eyes documented a success rate of 60 % at 1 year follow up with a stormier follow up requiring more interventions than the control trabeculectomy group which had a better success rate of 80%. A prior study by Wilson et al has compared AGV tube to trabeculectomy in both angle closure and open angle glaucoma patients of south east Asian ethnicity, and documented trabeculectomy to be initially more effective at 1 year but similar effect being attained at 5 years. 12 The TVT study confirms more effectivity of trabeculectomy group at one year follow up requiring less anti-glaucoma medications, with this edge being lost at longer follow up of 3 years where IOP control and anti-glaucoma medication requirement became similar for both tubes and trabeculectomy. 13 Present study employed silicone AGV with the smaller dimension pediatric model (FP7) the use of which has been described by prior studies. 14-16 Common complication of iris migration and subsequent tube plugging has been previously reported in this subset of glaucoma cases and is attributed to thicker iris tissue in eyes with crowded anterior chamber parameters. 17,18 The means employed to relieve this induced tube blockage have been traditionally argon / Nd YAG laser application or surgery. 19 In present study, we overcame this problem by creating a small corneal incision adjacent to site of tube entry and performing a generous surgical peripheral iridectomy. Another modification performed was leaving a smaller tube segment of 1.5 mm compared to the conventional 2-2.5 mm in the anterior chamber in these eyes with crowding angle morphology which resulted in less contact of tube with iris and lesser chance of the thicker iris telescoping into bevel of tube. Complications noted in the tube group involved tube retraction and erosion in 2 and 1 eye respectively requiring surgical revision. The increase in anterior segment inflammation noted in tube implanted eyes could be a result of increased tissue insult subsequent to increased dissection of subconjunctival space. The creation of surgical PI with GDD (not the normal norm) could also contributed to inflammation. Trabeculectomy eyes fared better in these aspects as evident in table 2. Conclusion Tube implants in ACG eyes are feasible as a primary option only with certain modifications and due precautions. Tube shunts despite these modifications fared poorer than trabeculectomy at 1 year follow up. Tubes should not be attempted as primary surgical means in advanced ACG cases. Trabeculectomy remains gold standard primary procedure in this subtype of glaucoma. Recommendations According to this pilot study, surgical recommendations are: s Creation of a surgical peripheral iridectomy immediately adjacent to the tube entry in addition to a patent pre operatively performed laser iridotomy at a different site. s Use of a smaller sized tube implant to prevent plate migration and extrusion. s Leaving a smaller tube segment residue of 1.5mm versus 2.5 mm in anterior chamber. 184

Cite This Article as: Singh K, Jain D, Sachdev M, Grover S. Tube Shunts in Advanced Angle Closure Glaucoma: A Pilot Study. Delhi J Ophthalmol 2017;27;181-5. Acknowledgements: None Date of Submission: 18/11/2016 Date of Acceptance: 06/12/2016 Conflict of interest: None declared Source of Funding: Nil References 1. Chen PP, Yamamoto T, Sawada A, Parrish RK 2nd, Kitazawa Y. Use of antifibrosis agents and glaucoma drainage devices in the American and Japanese Glaucoma Societies. J Glaucoma 1997; 6:192-6. 2. Joshi AB, Parrish RK 2nd, Feuer WF. 2002 survey of the American Glaucoma Society: practice preferences for glaucoma surgery and antifibrotic use. J Glaucoma 2005; 14:172-4. 3. Gedde SJ, Schiffman JC, Feuer WJ. Treatment outcomes in the tube versus trabeculectomy study after one year of follow-up. Am J Ophthalmol 2007; 143:9-22. 4. Migdal C, Hitchings R. The developing bleb: effect of topical antiprostaglandins on the outcome of glaucoma fistulising surgery. Br J Ophthalmol 1983; 67:655-60. 5. Wilson RP. Technical advances in filtration surgery. In: McAllister JA, Wilson RP, (eds). Glaucoma. Boston. Butterworths, 1986: pp.243-50. 6. Da Mata A, Burk SE, Netland PA, Baltatzis S, Christen W, Foster CS.Management of uveitic glaucoma with Ahmed glaucoma valve implantation. Ophthalmology 1999; 106:2168-72. 7. Yalvac IS, Eksioglu U, Satana B, Duman S. Long-term results of Ahmed glaucoma valve and Molteno implant in neovascular glaucoma. Eye 2007; 21:65-70. 8. Souza C, Tran DH, Loman J, Law SK, Coleman AL, Caprioli J. Long-term outcomes of Ahmed glaucoma valve implantation in refractory glaucomas. Am J Ophthalmol 2007; 144:893-900. 9. Williams AS. Setons in glaucoma surgery.in: Albert DM, Jakobiec FA, editors. Principles and practice of ophthalmology: clinical practice.philadelphia: W B Sauders 1994:1655-67. 10. Rosenberg LF, Krupin T.Implants in glaucoma surgery.in: itch R, Shields MB, Krupin T, editors.the glaucomas. Philadelhia: Mosby 1996; 1783-1807. 11. Coleman AL, Hill R, Wilson MR, Choplin N, Kotas-Neumann R, Tam M. Initial clinical experience with the Ahmed Glaucoma Valve implant. Am J Ophthalmol 1995; 120:23-31. 12. Wilson MR, Mendis U, Paliwal A, Haynatzka V. Long-term follow-up of primary glaucoma surgery with Ahmed glaucoma valve implant versus trabeculectomy. Am J Ophthalmol 2003; 136:464-70. 13. Gedde SJ, Schiffman JC, Feuer WJ, Herndon LW, Brandt JD, Budenz DL. Tube Versus Trabeculectomy Study Group. Three-year follow-up of the tube versus trabeculectomy study. Am J Ophthalmol 2009; 148:670-84. 14. Law SK, Nguyen A, Coleman AL, Caprioli J. Comparison of safety and efficacy between silicone and polypropylene Ahmed glaucoma valves in refractory glaucoma. Ophthalmology 2005; 112:1514-20. 15. Brasil MV, Rockwood EJ, Smith SD. Comparison of silicone and polypropylene Ahmed Glaucoma Valve implants. J Glaucoma 2007;16:36-41. 16. Hinkle DM, Zurakowski D, Ayyala RS. A comparison of the polypropylene plate Ahmed glaucoma valve to the silicone plate Ahmed glaucoma flexible valve. Eur J Ophthalmol 2007; 17:696-701 17. Brown RD, Cairns JE. Experience with the Molteno long tube implant. Trans Ophthalmol Soc U K 1983;103:297-312. 18. Schocket SS, Nirankari VS, Lakhanpal V, Richards RD, Lerner BC. Anterior chamber tube shunt to an encircling band in the treatment of neovascular glaucoma and other refractory glaucomas. A long-term study. Ophthalmology 1985; 92:553-62. 19. Molteno AC. The use of draining implants in resistant cases of glaucoma. Late results of 110 operations. Trans Ophthalmol Soc N Z 1983; 35:94-7. Corresponding author: Divya Jain MS, DNB Ex. Senior Resident, Department of Ophthalmology, Guru Nanak Eye Centre, Maulana Azad Medical College. Email id: divyajain@gmail.com 185