Advance Publication by-j-stage

Similar documents
30-Day Outcomes Following Implantation of a Repositionable Self-Expanding Aortic Bioprosthesis: First Report From the FORWARD Study

CIPG Transcatheter Aortic Valve Replacement- When Is Less, More?

Ian T. Meredith AM. MBBS, PhD, FRACP, FCSANZ, FACC, FAPSIC. Monash HEART, Monash Health & Monash University Melbourne, Australia

Prosthesis-Patient Mismatch in High Risk Patients with Severe Aortic Stenosis in a Randomized Trial of a Self-Expanding Prosthesis

Transcatheter Aortic Valve Replacement with a Self-Expanding Prosthesis or Surgical Aortic Valve Replacement in Intermediate-Risk Patients:

Incorporating the intermediate risk in Transcatheter Aortic Valve Implantation (TAVI)

Trend and Outcomes of Direct Transcatheter Aortic Valve Replacement from a Single-Center Experience

Transcatheter aortic valve implantation for severe aortic valve stenosis with the ACURATE neo2 valve system: 30-day safety and performance outcomes

Transcatheter Aortic Valve Implantation. SSVQ November 23, 2012 Centre Mont-Royal 15:40

TAVR-Update Andrzej Boguszewski MD, FACC, FSCAI Vice Chairman, Cardiology Mid-Michigan Health Associate Professor Michigan State University, Central

LOW RISK TAVR. WHAT THE FUTURE HOLDS

Aortic Stenosis: Interventional Choice for a 70-year old- SAVR, TAVR or BAV? Interventional Choice for a 90-year old- SAVR, TAVR or BAV?

Transcatheter Aortic Valve Replacement with a Repositionable Self-expanding Bioprosthesis in Patients With Severe Aortic Stenosis Suboptimal for

For the SURTAVI Investigators

Outcomes in the Commercial Use of Self-expanding Prostheses in Transcatheter Aortic Valve Replacement: A Comparison of the Medtronic CoreValve and

TAVR IN INTERMEDIATE-RISK PATIENTS

Edwards Sapien. Medtronic CoreValve. Inoperable FDA approved High risk: in trials. FDA approved

Supplementary Online Content

2/15/2018 DISCLOSURES OBJECTIVES. Consultant for BioSense Webster, a J&J Co. Aortic stenosis background. Short history of TAVR

Nouvelles indications/ Nouvelles valves

Neal Kleiman, MD Houston Methodist DeBakey Heart and Vascular Institute

Outcome of Next-Generation Transcatheter Valves in Small Aortic Annuli: A Multicenter Propensity-Matched Comparison

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Transcatheter aortic valve replacement is considered investigational for all other indications.

Transcatheter Aortic Valve Replacement

TAVI- Is Stroke Risk the Achilles Heel of Percutaneous Aortic Valve Repair?

Transcatheter Aortic-Valve Implantation for Aortic Stenosis

TAVR in 2017 What we know? What to expect?

1-YEAR OUTCOMES FROM JOHN WEBB, MD

Indication, Timing, Assessment and Update on TAVI

Transcatheter Aortic-Valve Implantation for Aortic Stenosis

TAVR in Intermediate Risk Populations /Optimizing Systems for TAVR

Is TAVR Now Indicated in Even Low Risk Aortic Valve Disease Patients

TAVR: Intermediate Risk Patients

TAVI: The Real Deal? Marc Pelletier, MD Head, Department of Cardiac Surgery New Brunswick Heart Centre

Multicentre clinical study evaluating a novel resheatable self-expanding transcatheter aortic valve system

Current Evidence in TAVI patients using ACURATE and LOTUS valves

Australia and New Zealand Source Registry Edwards Sapien Aortic Valve 30 day Outcomes

Paris, August 28 th Gian Paolo Ussia on behalf of the CoreValve Italian Registry Investigators

Igor Palacios, MD Director of Interventional Cardiology Massachusetts General Hospital Professor of Medicine Harvard Medical School

Severe Aortic Valve Disease: TAVR in Four Ages and Four Etiologies Age 25 y/o Congenital, 50 y/o Bicuspid, 75 y/o Rheumatic, 100 y/o Degenerative

Appropriate Use of TAVR - now and in the future. A Surgeon s Perspective. Neil Moat Royal Brompton Hospital, London, UK

Transcatheter Aortic Valve Replacement: Current and Future Devices: How do They Work, Eligibility, Review of Data

TAVR 2018: TAVR has high clinical efficacy according to baseline patient risk! ii. Con

TAVI in Korea, How to Avoid Conduction

Is TAVR the treatment of choice for high risk diabetic patients with aortic stenosis? Insights from the FRANCE2 Registry

Aortic Stenosis and TAVR TARUN NAGRANI, MD INTERVENTIONAL AND ENDOVASCULAR CARDIOLOGIST, SOMC

Variability in Antithrombotic Therapy Regimens Peri-TAVR: A Single Academic Center Experience

Transcatheter Aortic-Valve Implantation for Aortic Stenosis

An Update on the Edwards TAVR Results. Zvonimir Krajcer, MD Director, Peripheral Intervention Texas Heart Institute at St.

Early Outcomes in Japanese Dialysis Patients Treated With Transcatheter Aortic Valve Implantation

CoreValve in a Degenerative Surgical Valve

Transcatheter Aortic-Valve Implantation for Aortic Stenosis

Dr.ssa Loredana Iannetta. Centro Cardiologico Monzino

2/28/2010. Speakers s name: Paul Chiam. I have the following potential conflicts of interest to report: NONE. Antegrade transvenous transseptal route

Transcatheter Aortic Valve Implantation (TAVI) - 5 important lessons learnt from HK experiences Michael KY Lee

Aortic valve implantation using the femoral and apical access: a single center experience.

TAVR SPRING 2017 The evolution of TAVR

e Corrado Tamburino, MD, PhD

Options for my no option Patients Treating Heart Conditions Via a Tiny Catheter

3 years after introduction of TAVI in QEH. Michael KY Lee On Behalf of QEH TAVI Heart Team Queen Elizabeth Hospital Hong Kong

Incidence and Management of Early Implant Failure after Transcatheter Aortic Valve Implantation

Aortic stenosis (AS) remains the most common

Transcatheter Heart Valve Procedures

Transcatheter Mitral Valve Repair: today and tomorrow Sponsored by Abbott. Chairperson: M. Haude Panellists: A. Al Nooryani, M.

Le TAVI pour tout le monde?

PARTNER 2A & SAPIEN 3: TAVI for intermediate risk patients

TAVI: Nouveaux Horizons

Percutaneous Treatment of Valvular Heart Diseases: Lessons and Perspectives. Bernard Iung Bichat Hospital, Paris

RANDOMISED TRIALS TAVI WITH SAVR STEPHAN WINDECKER AORTIC VALVE DISEASE COMPARING

After PARTNER 2A/S3i and SURTAVI: What is the Role of Surgery in Intermediate-Risk AS Patients?

Role of Embolic Protection during TAVR

Repair or Replacement

Transcatheter Therapies For Aortic Valve Disease. March 2017 Brian Whisenant MD

Tissue vs Mechanical What s the Data??

Successful Transfemoral Edwards Sapien Aortic. Valve Implantation in a Patient with Previous. Mitral Valve Replacement

Is TAVI ready for prime time in: - Intermediate risk patients? - Low risk patients?

Case Presentations TAVR: The Good Bad and The Ugly

Interventional procedures guidance Published: 26 September 2014 nice.org.uk/guidance/ipg504

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

TRANSCATHETER HEART VALVE PROCEDURES

Update interventional Cardiology Hans Rickli St.Gallen

Is Stroke Frequency Declining?

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE

TRANSCATHETER HEART VALVE PROCEDURES

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE

30-day Outcomes of The CENTERA Trial a New Self-Expanding Transcatheter Heart Valve. Didier Tchétché, MD On Behalf of the CENTERA Investigators

How Do I Evaluate a Patient Being Considered for TAVR? Sunday, February 14, :00 11:25 PM 25 min

16 YEAR RESULTS Carpentier-Edwards PERIMOUNT Mitral Pericardial Bioprosthesis, Model 6900

stenosis (AS) at our center between June 2007 and December 2010, with last follow-up contact in 2016.

Bicuspid aortic root spared during ascending aorta surgery: an update of long-term results

Transcatheter aortic valve implantation for aortic stenosis

Measuring the risk in valve patients Lessons learnt from the TAVI story? Bernard Iung Bichat Hospital, Paris, France

Interventional procedures guidance Published: 26 July 2017 nice.org.uk/guidance/ipg586

TAVR today: High Risk, Intermediate Risk Population, and Valve in Valve Therapy

Bernard De Bruyne, MD, PhD Cardiovascular Center Aalst OLV-Clinic Aalst, Belgium

The advent of transcatheter aortic valve implantation. Vascular Complications Among Patients. cover story

Treatment of Bio-Prosthetic Valve Deterioration Using Transcatheter Techniques

Transcatheter Aortic Valve Implantation (TAVI)

Transcription:

Circ J doi: 10.1253/circj.CJ-17-0112 LATE BREAKING CLINICAL TRIAL (JCS 2017) Midterm Outcomes With a Self-Expandable Transcatheter Heart Valve in Japanese Patients With Symptomatic Severe Aortic Stenosis Yoshiki Sawa, MD, PhD; Kei Torikai, MD, PhD; Junjiro Kobayashi, MD, PhD; Hiroshi Niinami, MD, PhD; Toru Kuratani, MD, PhD; Koichi Maeda, MD; Hideaki Kanzaki, MD; Nobuyuki Komiyama, MD, PhD; Yutaka Tanaka, MD, PhD; Angie Zhang; Shigeru Saito, MD Background: Transcatheter aortic valve implantation (TAVI) is a viable alternative to surgical aortic valve replacement in high-risk or inoperable patients with aortic stenosis (AS). Here we report the midterm outcomes of high-risk Japanese patients with severe AS who underwent TAVI with a self-expandable TAV. Methods and Results: The CoreValve Japan Trial was a prospective, multicenter trial of the CoreValve System. A group of 55 patients (mean age 82.5±5.5 years, 30.9% male, 100% NYHA class III/IV, STS 8.0±4.2%) were enrolled in the 26-mm/29-mm CoreValve study, and 20 patients (mean age 81.0±6.6 years, 5.0% male, 100% NYHA class III/IV, STS 7.0±3.3%) were enrolled in the 23-mm CoreValve study, which started 1 year later. For the 26-mm/29-mm cohort, the 3-year all-cause mortality rate was 32.6%; major stroke was 15.4%. Mean pressure gradient (MPG), effective orifice area (EOA), and NYHA class showed sustained improvement. Paravalvular regurgitation (PVR) at 3 years was 28.6% (none), 25.7% (trace), 40.0% (mild), 5.7% (moderate), and 0.0% (severe). For the 23-mm cohort, the 2-year all-cause mortality rate was 5.0%; major stroke was 5.0%. MPG, EOA, and NYHA class showed sustained improvement. PVR at 2 years was 16.7% (none), 33.3% (trace), 44.4% (mild), 5.6% (moderate), and 0.0% (severe). Conclusions: TAVI with the CoreValve System was associated with sustained clinical and functional cardiac improvement in high surgical risk Japanese patients with severe AS. (Clinicaltrials.gov Identifiers: NCT01437098 and NCT01634269.) Key Words: Aortic valve stenosis; Midterm follow-up; Transcatheter aortic valve implantation Transcatheter aortic valve implantation (TAVI) has been well-studied in the United States, Canada, and Europe, where it has been shown to be an acceptable therapeutic alternative to surgical AV replacement in highrisk or otherwise inoperable patients with severe, symptomatic aortic stenosis (AS). 1 3 We recently reported the early outcomes of TAVI with the 26-mm and 29-mm CoreValve TAV (Medtronic, Minneapolis, MN, USA) in Japanese patients with severe, symptomatic AS who were deemed to be at high risk for surgical AV replacement. 4 The CoreValve is a trileaflet, bioprosthetic, porcine pericardial tissue valve mounted and sutured in a self-expanding nitinol stent frame. The bioprosthesis is housed in a collapsed position for percutaneous delivery via an 18Fr catheter-based technique and then implanted within the diseased AV. Data obtained at 6 months showed the CoreValve System to be safe and effective for the treatment of Japanese patients with severe AS. 4 Here we report the 3-year clinical outcomes and performance of the CoreValve bioprosthesis in the same patient cohort. Additionally, we report the 2-year outcomes of a separate cohort of Japanese patients with severe AS who had a small aortic annulus and received the 23-mm CoreValve bioprosthesis, which became available 1 year after the start of the 26-mm/29-mm CoreValve study. Methods Study Design The CoreValve Japan Trial was a prospective, multicenter, Received February 1, 2017; revised manuscript received March 9, 2017; accepted March 10, 2017; released online March 17, 2017 Time for primary review: 21 days Osaka University Hospital, Osaka (Y.S., K.T., T.K., K.M.); Shonan Kamakura General Hospital, Kamakura (Y.T., S.S.); National Cerebral and Cardiovascular Center, Suita (J.K., H.K.); Saitama Medical University International Medical Center, Saitama (H.N., N.K.), Japan; and Medtronic, Minneapolis, MN (A.Z.), USA This paper was presented at the 81 st Annual Scientific Meeting of the Japanese Circulation Society, Late Breaking Clinical Trials 1-2 (March 17, 2017, Kanazawa, Japan). Mailing address: Yoshiki Sawa, Professor, MD, PhD, Department of Cardiovascular Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita 565-0871, Japan. E-mail: sawa@surg1.med.osaka-u.ac.jp ISSN-1346-9843 All rights are reserved to the Japanese Circulation Society. For permissions, please e-mail: cj@j-circ.or.jp

SAWA Y et al. single-arm trial to evaluate the efficacy and safety of the 23-, 26-, and 29-mm CoreValve TAV for the treatment of symptomatic, severe AS in Japanese patients who were high-risk surgical AV replacement candidates. The study s design has been previously reported. 4 Briefly, key patient inclusion criteria were severe symptomatic AS with a mean gradient >40 mmhg and an aortic valve area 0.8 cm 2. Primary anatomical exclusion criteria were: a native aortic annulus size <20 mm or >27 mm for the 26-mm/29-mm cohort and <18 mm or >20 mm for the 23-mm cohort; a pre-existing prosthetic heart valve in any position; mixed AV disease with predominant aortic regurgitation (AR); moderate to severe mitral or tricuspid valve regurgitation; an ascending aorta diameter >40 mm for the 26-mm/29-mm cohort and >34 mm for the 23-mm cohort; bicuspid or unicuspid valve; or femoral or iliac arterial diameter <6 mm (unable to accommodate an 18Fr sheath). Native aortic annuli were measured using computed tomography (CT) and transthoracic or transesophageal echocardiography; however, CT was the primary method used. Major-minor aortic annulus diameter and aortic annulus perimeter assessments were performed. Preprocedural CT was mandatory in the CoreValve Japan Studies, and all patients met this study requirement. Antiplatelet and anticoagulation therapies including daily aspirin 81 325 mg and ticlopidine (according to the manufacturer s instructions for use) were recommended for at least 3 months following the procedure. Continuation beyond 3 months was left to the treating physician s discretion. The primary endpoint for the study was a composite of improvement of at least 1 New York Heart Association (NYHA) class and an effective orifice area (EOA) of >1.2 cm 2 for the 26-mm/29-mm valve cohort or 1.0 cm 2 for the 23-mm valve cohort at 6 months post-procedure in patients who underwent TAVI with the CoreValve via iliofemoral access. The primary endpoint result for the 26-mm/29-mm valve cohort has been previously reported; 4 the primary endpoint for the 23-mm valve cohort is presented in this report. Additionally, for both cohorts, key endpoints analyzed were major adverse cardiovascular and cerebrovascular events (MACCE), NYHA class, echocardiographic valve assessment, valve-related death, adverse events, and quality of life. Except for the primary endpoint for the 23-mm cohort, results are reported for each study arm s cohort in aggregate regardless of the TAVI access approach. Definitions Myocardial infarction (MI), stroke, vascular complications, life-threatening or disabling bleeding events, and paravalvular regurgitation (PVR) were defined using Valve Academic Research Consortium (VARC) I definitions, which were the current VARC definitions in use when this study was conducted. 5 MACCE was defined as a composite rate of all-cause death, MI, all stroke and reintervention. Reintervention was defined as any cardiac surgery or percutaneous catheter intervention (PCI) procedure that repaired, otherwise altered or adjusted, or replaced a previously implanted valve. Valve-related death was defined as any death caused by prosthetic valve dysfunction, valve thrombosis, embolism, bleeding event, or implanted valve endocarditis or related to reintervention on the operated valve. Quality of life was evaluated using the Short Form (SF)-36 health survey. Study Oversight An independent Echocardiographic Core Laboratory (Mayo Clinic Echocardiographic Core Laboratory, Rochester, MN, USA) was responsible for the review and analysis of echocardiographic images. A Clinical Events Committee (CEC), also independent from the study investigators, evaluated all clinical endpoints. The study was conducted in accordance with the ethical principles originating from the Declaration of Helsinki, pharmaceutical affairs law, and good clinical practice. The institutional review board at each center approved the study protocol, and a signed informed consent form was received from all patients. Statistical Analysis Descriptive statistics were used to report baseline demographics and clinical variables. For the 23-mm cohort, the comparator for the primary study objective was conventional therapy, which included medical management and balloon aortic valvuloplasty. Categorical variables are summarized as frequencies and percentages. Continuous variables are summarized as mean ± standard deviation. For NYHA class, echocardiographic assessment of valve performance, and the SF-36, Wilcoxon signed-rank tests were performed to evaluate the median change from baseline at discharge, then 1, 6, 12, and 24 months (23-mm CoreValve cohort), and discharge, and 1, 6, 12, 24, and 36 months (26-mm/29-mm CoreValve cohort) for implanted patients. Kaplan-Meier analyses were performed for safety endpoints. Results Patients Characteristics From October 2011 to October 2012, 55 patients with severe symptomatic AS were enrolled at 4 investigational centers in Japan, of whom 44 underwent attempted TAVI with the 26- or 29-mm CoreValve via the iliofemoral approach, 5 by the subclavian route, and 6 by the direct aortic approach; 38 (70.4%) patients received the 26-mm valve and 16 (29.6%) received the 29-mm valve. For all patients, mean age was 82.5±5.5 years, 30.9% were male, mean Society of Thoracic Surgeons (STS) score was 8.0±4.2%, mean logistic EuroSCORE was 21.5±9.9%, and all patients had NYHA class III (89.1%) or IV (10.9%) symptoms. From July 2012 to August 2013, 20 patients with severe, symptomatic AS and a small aortic annulus were enrolled at the same 4 investigational centers in Japan, of whom 16 underwent attempted TAVI with the 23-mm CoreValve via the iliofemoral approach and 4 by the direct aortic approach. For all patients, mean age was 81.0±6.6 years, 5.0% were male, mean STS score was 7.0±3.3%, mean logistic EuroSCORE was 22.3±10.1%, and all patients had NYHA class III (95.0%) or IV (5.0%) symptoms. Baseline characteristics for both cohorts are summarized in Table 1. Patient disposition for both cohorts is presented in Figure 1. Clinical Outcomes 26-mm/29-mm Cohort Kaplan-Meier rates for adverse events for patients in the 26-mm/29-mm CoreValve cohort are presented in Table 2. The Kaplan-Meier rate for allcause death was 13.0% at 1 year, 18.7% at 2 years, and 32.6% at 3 years (Figure 2). Two deaths were adjudicated

Midterm Outcomes for Self-Expandable THV in Japan Table 1. Baseline Patient Characteristics in the CoreValve Japan Trial Characteristic 26/29 mm 23 mm All patients (n=55) All patients (n=20) Age (years) 82.5±5.5 81.0±6.6 Male 17 (30.9) 1 (5.0) NYHA classification II 0 (0.0) 0 (0.0) III 49 (89.1) 19 (95.0) IV 6 (10.9) 1 (5.0) STS score (%) 8.0±4.2 7.0±3.3 <4 7 (12.7) 1 (5.0) 4 10 34 (61.8) 16 (80.0) >10 14 (25.5) 3 (15.0) Logistic EuroSCORE (%) 21.5±9.9 22.3±10.1 Diabetes mellitus 19 (34.5) 3 (15.0) Creatinine level >2 mg/dl 0 (0.0) 0 (0.0) History of hypertension 50 (90.9) 16 (80.0) Peripheral vascular disease 18/53 (34.0) 8 (40.0) Prior stroke 15/54 (27.8) 0 (0.0) Prior TIA 3/54 (5.6) 0 (0.0) Cardiac history CAD 27 (49.1) 10 (50.0) Prior CABG 11 (20.0) 3 (15.0) Prior PCI 17 (30.9) 6 (30.0) Prior balloon valvuloplasty 3 (5.5) 1 (5.0) Previous MI 5 (9.1) 1 (5.0) Pre-existing pacemaker 3 (5.5) 0 (0.0) Congestive heart failure 49 (89.1) 16 (80.0) Prior atrial fibrillation/atrial flutter 7/54 (13.0) 5 (25.0) Chronic lung disease/chronic obstructive pulmonary disease 24 (43.6) 14 (70.0) Echocardiographic parameters MPG (mmhg) 57.8±16.1 63.4±18.0 Mean aortic valve area (cm 2 ) 0.6±0.1 0.5±0.1 Moderate or severe AR 3 (5.5) 1 (5.0) Frailty Anemia with transfusion 1 (1.8) 1 (5.0) BMI <21 kg/m 2 16 (29.1) 8 (40.0) Albumin <3.3 g/dl 3/54 (5.6) 1 (5.0) Unplanned weight loss 7 (12.7) 3 (15.0) Fall in past 6 months 2 (3.6) 2 (10.0) 5-m gait speed (s) 8.5±4.2 (n=39) 8.1±4.2 (n=19) 5-m gait speed >6 s 30/39 (76.9) 12/19 (63.2) Grip strength below threshold 50 (90.9) 17 (85.0) Disability Wheelchair bound 16 (29.1) 5 (25.0) Does not live independently 17 (30.9) 8 (40.0) Does not bathe independently 16 (29.1) 8 (40.0) Does not dress independently 3 (5.5) 2 (10.0) Does not toilet independently 4 (7.3) 1 (5.0) Does not transfer independently 10 (18.2) 3 (15.0) Values are mean ± SD or N (percentages) or n/n (percentages). AR, aortic regurgitation; BMI, body mass index; CABG, coronary artery bypass surgery; CAD, coronary artery disease; MI, myocardial infarction; MPG, mean pressure gradient; NYHA, New York Heart Association; PCI, percutaneous coronary intervention; STS, Society of Thoracic Surgeons; TIA, transient ischemic attack. by the CEC as valve-related. One patient underwent successful implantation of a 26-mm CoreValve bioprosthesis but became unstable after transfer to the intensive care unit and subsequently underwent pericardiocentesis. The next evening emergency surgery revealed a left retroperitoneal hemorrhage from the left external iliac artery, the patient remained unstable and died on postoperative day 2. The other patient died from an intracranial bleed 3 years

SAWA Y et al. Figure 1. Patient disposition for the 26-mm/29-mm and 23-mm CoreValve cohorts. Table 2. Kaplan-Meier Rates of Adverse Events to 3 Years for Patients Receiving the 26-mm or 29-mm CoreValve (n=55) Assessment 1 month 6 months 1 year 2 years 3 years MACCE 6 (10.9) 10 (18.4) 13 (23.9) 17 (31.4) 23 (42.7) All-cause death 1 (1.8) 5 (9.2) 7 (13.0) 10 (18.7) 17 (32.6) Cardiovascular death 1 (1.8) 3 (5.5) 3 (5.5) 5 (9.6) 8 (17.2) Stroke 4 (7.4) 5 (9.3) 6 (11.4) 8 (15.7) 10 (21.0) Major stroke 2 (3.7) 2 (3.7) 3 (5.8) 5 (10.1) 7 (15.4) Ischemic 1 (1.9) 1 (1.9) 2 (3.9) 4 (8.3) 5 (10.9) Hemorrhagic 1 (1.9) 1 (1.9) 1 (1.9) 1 (1.9) 2 (4.9) Myocardial infarction 2 (3.6) 2 (3.6) 2 (3.6) 2 (3.6) 2 (3.6) Reintervention 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Valve thrombosis* 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Major vascular complication 6 (10.9) 6 (10.9) 6 (10.9) 6 (10.9) 6 (10.9) Life-threatening/disabling bleeding 7 (12.8) 8 (14.7) 9 (16.6) 10 (18.7) 11 (21.5) Atrial fibrillation** 3/51 (5.9) 5/47 (10.6) 6/45 (13.3) 4/42 (9.5) 3/36 (8.3) Permanent pacemaker 12 (22.2) 14 (26.3) 14 (26.3) 15 (28.6) 15 (28.6) Data reported as no. of patients (Kaplan-Meier rates as percentages). *Doppler ultrasound echocardiography used for valve thrombosis evaluation. **Atrial fibrillation is reported as incidence [n/n, (percentage)] and not as a Kaplan-Meier rate. MACCE, major adverse cardiovascular and cerebrovascular events. post-procedure. The definition of a valve-related death includes any death caused by prosthetic valve dysfunction, valve thrombosis, embolism, bleeding event, or implanted valve endocarditis or related to reintervention on the operated valve. No patients required reintervention through 3 years follow-up. Two cases of MI occurred within 1 month of the procedure. The first patient had a history of prior coronary artery bypass grafting and PCI. Following valve implantation, a post-tavr balloon valvuloplasty was performed after moderate AR was noted. The patient became hypotensive and coronary angiography revealed absence of flow in the left circumflex coronary artery. Creatinine kinase (CK) and troponin levels the following day confirmed the MI. On the 2nd postoperative day PCI of the affected vessel was performed. The second patient also had a history of prior PCI. During the TAVR procedure cardiac perforation and tamponade occurred after pre-tavr balloon valvuloplasty. Transient myocardial damage caused by hypotension was suspected, which was treated with percutaneous cardiopulmonary support. CK and CK MB elevation was noted on the 1st postoperative day, but no ischemic-event related ECGs were provided. The CEC noted that the periprocedural MI was related to the CoreValve device. There were no subsequent cases of MI reported through 3 years; thus, the rate for MI remained 3.6%. The rate of major stroke was 5.8% at 1 year, 10.1% at 2 years, and 15.4% at 3 years; however, only 3 of the 7 major strokes that occurred over the 3-year follow-up were adjudicated by the CEC as related to the device or procedure. The CEC adjudicated stroke events by a few criteria, one of which was proximity to the implant procedure. For 2 of the patients, the stroke event occurred within 30 days of the implant procedure, so was adjudicated as related to the device or procedure. In the 3rd patient, the stroke

Midterm Outcomes for Self-Expandable THV in Japan Figure 2. Kaplan-Meier estimates of all-cause mortality to the longest follow-up for each cohort. Figure 4. Paravalvular regurgitation over time for the (A) 26-mm/29-mm CoreValve cohort and (B) 23-mm CoreValve cohort. Note the follow-up time points vary for each panel based on completed follow-up for each cohort. Figure 3. New York Heart Association (NYHA) class over time for the (A) 26-mm/29-mm CoreValve cohort and (B) 23-mm CoreValve cohort. Note the follow-up time points vary for each panel based on completed follow-up for each cohort. occurred 605 days after the implant procedure, but the patient also had endocarditis, attributed to the valve, and the CEC considered the stroke likely device-related because of the valve-associated endocarditis. There were no signs of valve deterioration or thrombus observed during followup. The rate of MACCE was 23.9%, 31.4%, and 42.7% at 1, 2, and 3 years, respectively. Using VARC I definitions, the rate of life-threatening or disabling bleeding was 16.6% at 1 year, 18.7% at 2 years, and 21.5% at 3 years. The rate of major vascular complications was 10.9% at 1 month and remained unchanged throughout the remainder of the follow-up period. Permanent pacemaker implantation was required in 14 patients in the 1st year of follow-up, with 1 additional patient needing a permanent pacemaker in the 2nd year, and none in the 3rd year. The pacemaker implantation rates are shown in Table 2. For patients with follow-up data, improvement in NYHA classification was sustained over 3 years (Figure 3A). As shown in Figure 4A, the rate of PVR remained stable over time, with 2 (5.7%) patients having moderate and no patients having severe PVR at 3 years. Improvements in mean pressure gradient (MPG) and EOA were also stable over time (Figure 5A). Quality of life measurements showed improvement in the SF-36 physical component summary score of 10.8 points (P=0.008) at 1 year, 9.3 points (P=0.002) at 2 years, and 4.8 points (P=0.151) at 3 years. However, the SF-36 mental component summary score showed only slight improvement, increasing by 2.8 points (P=0.016) at 1 year, 2.9 points (P=0.220) at 2 years, and 1.5 points (P=0.240) at 3 years. 23-mm Cohort A total of 16 iliofemoral patients were

SAWA Y et al. Figure 5. Mean pressure gradient and effective orifice area over time for the (A) 26-mm/29-mm CoreValve cohort and (B) 23-mm CoreValve cohort. Note the follow-up time points vary for each panel based on completed follow-up for each cohort. enrolled in the 23 mm study. Analysis of the primary endpoint showed that iliofemoral patients achieved a composite NYHA and EOA success rate of 87.5% (14/16). The lower bound of the 2-sided 95% confidence interval was 61.7%, indicating the performance of the 23-mm CoreValve was superior to conventional therapy outcomes of 50% improvement and the primary study objective was met (P=0.002). Kaplan-Meier rates for adverse events for patients in the 23-mm CoreValve cohort (n=20) are presented in Table 3. The Kaplan-Meier rate for all-cause death was 0.0% at 1 year, and 5.0% at 2 years (Figure 2). No cases of MI, reintervention, or valve-related death occurred through 2 years. The rate of major stroke was 0.0% at 1 year and 5.0% at 2 years. The rate of MACCE was 0.0% at 30 days, 5.0% at 6 months and 1 year, and 10.0% at 2 years. Using VARC I definitions, the rate of life-threatening or disabling bleeding was 10.0% at 30 days, 15% at 1 year, and remained unchanged at 2 years. The rate of major vascular complications was 15% at 30 days and remained unchanged throughout the remainder of the follow-up period. Permanent pacemaker implantation was required in 4 patients in the 1st month of follow-up, with an additional patient needing a permanent pacemaker in the 1st year, and none in the 2nd year. The percentages of patients with a pacemaker are shown in Table 3. At baseline, all patients were in NYHA class III or IV; all patients followed to 6 months were in NYHA class I or II and remained so through 2 years (Figure 3B). PVR showed sustained improvement over time, with only one (5.6%) patient having moderate and no patients having severe PVR at 2 years (Figure 4B). Improvements in MPG and EOA also remained stable over time (Figure 5B). There was no statistically significant improvement in the SF-36 physical or mental component summary scores through 2 years of follow-up. Discussion This study reports the midterm experience with the Table 3. Kaplan-Meier Rates of Adverse Events to 2 Years for Patients Receiving the 23-mm CoreValve (n=20) Assessment 1 month 6 months 1 year 2 years MACCE 0 (0.0) 1 (5.0) 1 (5.0) 2 (10.0) All-cause death 0 (0.0) 0 (0.0) 0 (0.0) 1 (5.0) Cardiovascular death 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Stroke 0 (0.0) 1 (5.0) 1 (5.0) 1 (5.0) Major stroke 0 (0.0) 0 (0.0) 0 (0.0) 1 (5.0) Ischemic 0 (0.0) 0 (0.0) 0 (0.0) 1 (5.0) Hemorrhagic 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Myocardial infarction 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Reintervention 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Valve thrombosis* 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Major vascular complication 3 (15.0) 3 (15.0) 3 (15.0) 3 (15.0) Life-threatening/disabling bleeding 2 (10.0) 3 (15.0) 3 (15.0) 3 (15.0) Atrial fibrillation** 2/20 (10.0) 1/20 (5.0) 2/20 (10.0) 1/18 (5.6) Permanent pacemaker 4 (20.0) 4 (20.0) 5 (25.0) 5 (25.0) Data reported as no. of patients (Kaplan-Meier rates as percentages). *Doppler ultrasound echo used for valve thrombosis evaluation. **Atrial fibrillation is reported as incidence [n/n, (percentage)] and not as a Kaplan-Meier rate. MACCE, major adverse cardiovascular and cerebrovascular events.

Midterm Outcomes for Self-Expandable THV in Japan CoreValve 23-, 26-, and 29-mm bioprostheses in the Japanese population. Overall, the results demonstrated that TAVI with the CoreValve System was associated with sustained clinical and functional cardiac improvement in high-risk Japanese patients with severe AS. In the 26-mm/29-mm cohort, MACCE occurred in 23 patients through 3 years of follow-up; 17 patients died, of whom 8 died from cardiac causes; 2 deaths were related to the TAV. The 3-year mortality rate was 32.6%. Although high, this mortality rate is not unexpected given the severity of AS, advanced age, and frailty of this patient cohort. The 3-year mortality rate is also similar to that reported by other larger studies evaluating the CoreValve in high-risk AS patients. 6,7 Stroke remains an important problem with any AV intervention, be it surgical or catheter-based. 8 In the 26-mm/29-mm CoreValve cohort, 7 patients experienced a major stroke through 3 years of follow-up, resulting in a Kaplan-Meier rate for major stroke of 15.4%, which is higher than that reported by larger, long-term studies of the CoreValve device; 8,9 however, the small sample size (n=55) in the present study had a larger effect on calculated event rates compared with other much larger CoreValve studies. Additionally, in review of the 7 major stroke events, only 3 were adjudicated by the CEC as being related to the CoreValve bioprosthesis or procedure. Of these, 1 was a subarachnoid hemorrhage, which occurred within 30 days of the procedure, and 2 were ischemic strokes, one of which occurred within 30 days of the procedure, and 1 which occurred between the 1- and 2-year follow-up visits. Cardiac conduction disorders requiring permanent pacemaker implantation are one of the most common complications seen after TAVI. In the present study, 15 patients who received either the 26-mm or 29-mm device required a permanent pacemaker through 3 years, resulting in a Kaplan-Meier rate of 28.6%. However, pacemaker implantation was required in the majority of cases (12 patients) within 30 days of the TAVI procedure. The incidence of permanent pacemaker implantation in the present study is similar to that reported for this TAV device, and several recent studies have found no adverse effect of permanent pacemaker implantation after TAVI with this device on stroke or survival. 10,11 Echocardiography core laboratory data continued to demonstrate the durability of the CoreValve bioprosthesis. No significant changes in the hemodynamic status of the implanted 26-mm/29-mm bioprostheses were seen, and the MPG and EOA remained stable from discharge to 3 years. There was no evidence of valve thrombosis during the follow-up period. PVR remained stable over time, with only 2 (5.7%) patients having moderate PVR and no patients having severe PVR at 3-year follow-up. In the 26-mm/29-mm cohort, NYHA functional classification showed sustained improvement over time, with all surviving patients classified as either NYHA class I or II at 3 years compared with class III or IV at baseline. There was also statistically significant improvement in the SF-36 physical component summary score through 2 years; however, this diminished by the 3rd year. The SF-36 mental component summary score showed only modest improvement, achieving statistical significance only at 1-year followup. Although the reason for the more limited improvement in the mental component summary results is unclear, other studies of TAVI in high-risk AS patients have documented similarly modest benefits in psychological measures. 12 We also evaluated the 2-year outcomes of a separate cohort of Japanese patients with severe AS and a small aortic annulus who received the 23-mm CoreValve bioprosthesis. Overall, this valve performed well in this patient group, and the primary endpoint was met. There were 3 cases of MACCE occurred in 2 patients: 1 patient died from non-cardiac causes, and 1 patient had 2 stroke events over 2 years; 5 patients required a permanent pacemaker through 2 years, resulting in a Kaplan-Meier rate of 25.0%. No significant changes post-procedure in the hemodynamic status of the implanted 23-mm bioprosthesis were seen and PVR was stable over time, with only one patient having moderate and no patients having severe PVR at 2 years. NYHA functional classification also showed sustained improvement over time. We did not observe significant improvement in the SF-36 physical or mental component summary scores at any follow-up time point, which may have been limited by the small study cohort. Study Limitations The primary limitation of both these studies was the small sample size, which also resulted in each event having a larger effect on event rates than is seen in larger trials. Conclusions This study demonstrated that TAVI with the self-expanding CoreValve was associated with sustained, multi-year clinical and functional cardiac improvement in high-risk surgical Japanese patients with severe, symptomatic AS. Disclosures Angie Zhang is an employee and shareholder of Medtronic, Plc. Acknowledgments The authors thank Janice Hoettels, PA, MBA and Jane Moore, MS, ELS for their assistance in the preparation of this manuscript. Both are employed by Medtronic. Funding This work was supported by Medtronic Japan Co. Ltd. References 1. Nishimura RA, Otto CM, Bonow RO, Carabello BA, Erwin JP III, Guyton RA, et al. 2014 AHA/ACC guideline for the management of patients with valvular heart disease: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. Circulation 2014; 129: e521 e643. 2. Webb J, Rodés-Cabau J, Fremes S, Pibarot P, Ruel M, Ibrahim R, et al. Transcatheter aortic valve implantation: A Canadian Cardiovascular Society position statement. Can J Cardiol 2012; 28: 520 528. 3. Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC); European Association for Cardio-Thoracic Surgery (EACTS), Vahanian A, Alfieri O, Andreotti F, Antunes MJ, Barón-Esquivias G, Baumgartner H, et al. Guidelines on the management of valvular heart disease (version 2012). Eur Heart J 2012; 33: 2451 2496. 4. Sawa Y, Saito S, Kobayashi J, Niinami H, Kuratani T, Maeda K, et al. First clinical trial of a self-expandable transcatheter heart valve in Japan in patients with symptomatic severe aortic stenosis. Circ J 2014; 78: 1083 1090. 5. Leon MB, Piazza N, Nikolsky E, Blackstone EH, Cutlip DE, Kappetein AP, et al. Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: A consensus report of the Valve Academic Research Consortium. Eur Heart J 2011; 32: 205 217. 6. Deeb GM, Reardon MJ, Chetcuti S, Patel HJ, Grossman PM,

SAWA Y et al. Yakubov SJ, et al. 3-year outcomes in high-risk patients who underwent surgical or transcatheter aortic valve replacement. J Am Coll Cardiol 2016; 67: 2565 2574. 7. Ussia GP, Barbanti M, Petronio AS, Tarantini G, Ettori F, Colombo A, et al. Transcatheter aortic valve implantation: 3-year outcomes of self-expanding CoreValve prosthesis. Eur Heart J 2012; 33: 969 976. 8. Gleason TG, Schindler JT, Adams DH, Reardon MJ, Kleiman NS, Caplan LR, et al. The risk and extent of neurologic events are equivalent for high-risk patients treated with transcatheter or surgical aortic valve replacement. J Thorac Cardiovasc Surg 2016; 151: 1718 1728. 9. Adams DH, Popma JJ, Reardon MJ, Yakubov SJ, Coselli JS, Deeb M, et al. Transcatheter aortic-valve replacement with a self-expanding prosthesis. N Engl J Med 2014; 370: 1790 1798. 10. Testa L, Latib A, De Marco F, De Carlo M, Agnifili M, Latini RA, et al. Clinical impact of persistent left bundle-branch block after transcatheter aortic valve implantation with CoreValve Revalving System. Circulation 2013; 127: 1300 1307. 11. Ledwoch J, Franke J, Gerckens U, Kuck KH, Linke A, Nickening G, et al. Incidence and predictors of permanent pacemaker implantation following transcatheter aortic valve implantation: Analysis from the German transcatheter aortic valve interventions registry. Catheter Cardiovasc Interv 2013; 82: E569 E577. 12. Kim CA, Rasania SP, Afilalo J, Popma JJ, Lipsitz LA, Kim DH. Functional status and quality of life after transcatheter aortic valve replacement: A systematic review. Ann Intern Med 2014; 160: 243 254.