Heart Rhythm Society 2017

Similar documents
2017 HRS Expert Consensus Statement on Cardiovascular Implantable Electronic Device Lead Management and Extraction

Lead extraction. Dr. Mervat Abo El Maaty Professor of Cardiology Ain shams University 2013

Infected cardiac-implantable electronic devices: diagnosis, and treatment

Technical option of surgical approach for trouble-shooting

Cardiac implantable electronic devices (CIEDs) in children include pacemakers and implantable cardioverter defibrillators (ICDs).

7. Echocardiography Appropriate Use Criteria (by Indication)

Complications of Lead Extraction: Prevention and treatment. Maria Grazia Bongiorni, MD, FESC

1. Patient Characteristics

ASE 2011 Appropriate Use Criteria for Echocardiography

Leadless Pacing. Osama Diab Assistant Prof. of Cardiology Ain Shams University Egypt

Infections Amenable to OPAT. (Nabin Shrestha + Ajay Mathur)

When Should I Order a Stress Test or an Echocardiogram

Adult Congenital Heart Disease Certification Examination Blueprint

When to implant an ICD in systemic right ventricle?

PRINCIPLES OF ENDOCARDITIS

Pediatric pacemakers & ICDs:

Supplemental Material

SUPPLEMENTAL MATERIAL

Implantation of Cardioverter Defibrillator After Percutaneous Closure of Atrial Septal Defect

Cardiac Imaging in abnormal rhythm Role of MDCT

Index. Note: Page numbers of article titles are in boldface type.

Tachycardia Devices Indications and Basic Trouble Shooting

MY CONFLICTS OF INTEREST ARE

Detailed Order Request Checklists for Cardiology

ARRHYTHMIAS AND DEVICE THERAPY

Girish M Nair, Seeger Shen, Pablo B Nery, Calum J Redpath, David H Birnie

Adult Echocardiography Examination Content Outline

Ultrasound-enhanced, catheter-directed thrombolysis for pulmonary embolism

Transvenous Pacemaker Procedures

Clinical Indications for Echocardiography

Pediatric Pacemaker Implantation Endocardial or Epicardial

HEART OF THE MATTER: cardiac issues in safe endoscopy & sedation

Different indications for pacemaker implantation are the following:

(Ann Thorac Surg 2008;85:845 53)

Echocardiography as a diagnostic and management tool in medical emergencies

CRF procedure PROCEDURE FLOW. PATIENT ASSESSMENT Symptoms and indication. Pacemaker & ICD registration. Procedures. Procedure ICD.

Riata Lead Extraction. Thomas D. Callahan, MD, FACC, FHRS

National Imaging Associates, Inc. Clinical guidelines CARDIAC CATHETERIZATION -LEFT HEART CATHETERIZATION. Original Date: October 2015 Page 1 of 5

University of Florida Department of Surgery. CardioThoracic Surgery VA Learning Objectives

Section 1: Initial Evaluation for Valvular Heart Disease Table 1: Initial Evaluation of an Asymptomatic Patient

Recent Advances in Pacing and Defibrillation Harish Doppalapudi, MD

Q & A: How to Safely Scan Patients with a SureScan MRI Pacemaker

Heart on Fire: Infective Endocarditis. Objectives. Disclosure 8/27/2018. Mary McGreal DNP, RN, ANP-c, CCRN

From the University of California Sulpizio Cardiovascular Center, San Diego, California.

Cigna - Prior Authorization Procedure List Cardiology

PERFORMANCE MEASURE TECHNICAL SPECIFICATIONS. HRS-3: Implantable Cardioverter-Defibrillator (ICD) Complications Rate

UnitedHealthcare Medicare Advantage Cardiology Prior Authorization Program

Lead Extraction Workshop. By Cook Medical

Patient guide: pfm Nit-Occlud PDA coil occlusion system. Catheter occlusion of. Patent Ductus Arteriosus. with the

Double Superior Vena Cava; A Benign Cause of Widened Mediastenum and Implication on Venous Central Access

Breakout Session: Transesophageal Echocardiography

Index. cardiology.theclinics.com. Note: Page numbers of article titles are in boldface type.

Microbiological diagnosis of infective endocarditis; what is new?

Daniel C. DeSimone, MD Assistant Professor of Medicine

Interventional procedures guidance Published: 26 September 2014 nice.org.uk/guidance/ipg504

Original Date: October 2009 TRANSESOPHAGEAL (TEE) ECHO Page 1 of 6

Call Medtronic at 1 (800) to verify the patient s current implanted system

Subcutaneous implantable cardioverter defibrillator insertion for preventing sudden cardiac death

Mitral Regurgitation

PACING AT THE BUNDLE OF HIS

April 16, 09:00-09:15 중앙대학교 윤신원

Cardiovascular Nursing Practice: A Comprehensive Resource Manual and Study Guide for Clinical Nurses 2 nd Edition

Lead Extraction: Challenges in our area

Advanced ICD Concepts

ESCMID Online Lecture Library. by author

Percutaneous Mitral Valve Repair. Transesophageal Echo Acquisition Guide

PACEMAKER LEAD ENDOCARDITIS (CDR-IE)

LEAD EXTRACTION GOOD LEAD MANAGEMENT. An update on how to achieve well functioning CIED hardware with a special focus on risk-benefit analysis

Advanced Electrophysiology Coding

Specific Basic Standards for Osteopathic Fellowship Training in Cardiology

General management of infective endocarditis

3/17/2014. WS # 3 ICD Registry Case Scenarios with Structural Abnormalities. Objectives. Denise Pond BSN, RN

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs

42yr Old Male with Severe AR Mild LV dysfunction s/p TOF -AV Replacement(tissue valve) or AoV plasty- Kyung-Hwan Kim

Keywords: Pacemaker, transvenous pacemaker, thrombosis, intracardiac thrombosis, transesophageal echocardiography, paediatrics

Charging Considerations. Agenda 1/30/2013

February Jean C. Russell, MS, RHIT Richard Cooley, BA, CCS

Arrhythmias and congenital heart disease

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART II

The Adolescent and Adult Congenital Heart Disease Program

11/21/18. EKG Pop Quiz. Michael Giocondo, MD Cardiac Electrophysiology Saint Luke s Cardiovascular Consultants

Pacing in patients with congenital heart disease: part 1

Dialysis Event Protocol

LVHN Cardiac Diagnostic Testing PCP/PCP Office Testing Cheat Sheet. September 2017

UnitedHealthcare, UnitedHealthcare of the River Valley and Neighborhood Health Partnership Cardiology Notification and Prior Authorization Program:

Case 47 Clinical Presentation

Implantable defibrillator lead extraction with optimized standard extraction techniques

AC Financial Services Reference Guide For Services referred to: Cardio Vascular Lab

Patient Information. Atrial Septal Defect (ASD) Repair

MEDTRONIC CARELINK NETWORK FOR PACEMAKERS. Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring

Cardiac tamponade and Pericardiocentesis Made Easy

MICRA TRANSCATHETER PACING SYSTEM (TPS) REIMBURSEMENT OVERVIEW

Case Report Subacute Staphylococcusepidermidis Bacterial Endocarditis Complicated by Mitral-Aortic Intervalvular Fibrosa Pseudoaneurysm

University of Wisconsin - Madison Cardiovascular Medicine Fellowship Program UW CICU Rotation Goals and Objectives

You Won t Believe What I Saw on. Disclosures. Goals. Dimensions 2013 October 18 th Michael Pfeiffer, MD. No Financial Disclosures

Implantation of a Cardiac Resynchronisation Therapy-Defibrillator (CRT-D)

Pediatric Echocardiography Examination Content Outline

CIEDs Infection: Lead Extraction, First or Last option?

Cardiac Diagnostic Testing Reference Guide January 2018

Transcription:

Lead management Summary statement Heart Rhythm Society 2017 Expert consensus statement 1 Recognized as a quality educational tool by the Heart Rhythm Society. 1

Table of contents Overview 3 Key takeaways 4 Treatment 6 Periprocedural management: preparatory phase 14 Patient clinical scenarios 16 nfection diagnosis and treatment 22 Abbreviations 27 The ideas and opinions expressed in this product do not necessarily reflect those of the Heart Rhythm Society (HRS). The mention of any product, service, or therapy in this training should not be construed as an endorsement. t is the responsibility of the treating physician or other health care provider, relying on independent experience and knowledge of the patient, to determine the best treatment for the patient. 2

Overview The 2017 consensus statement focuses on providing practical clinical guidance in lead management and lead extraction to help clinicians in their decision-making process for managing leads. The 2017 consensus builds on the 2009 consensus document. 2 The 2009 consensus recommendations on facilities and training for lead extraction remain appropriate. 1.2-1.4 million CEDs are implanted annually worldwide. Although recent technological advances have eliminated the need for transvenous or epicardial leads for CEDs used in selected groups of patients, lead management remains important. Careful consideration with the patient on the decision on whether to abandon or remove a lead is recommended before starting the procedure. (COR ; LOE ) Developed in collaboration with: American College of Cardiology (ACC) American Heart Association (AHA) Asia Pacific Heart Rhythm Society (APHRS) American Society of Anesthesiologists (ASA) European Heart Rhythm Association (EHRA) nfectious Diseases Society of America (DSA) Latin American Heart Rhythm Society (LAHRS) Pediatric and Congenital Electrophysiology Society (PACES) Society of Thoracic Surgeons (STS) 3

Key takeaways nfection nfection remains a Class indication for removal of all hardware. Extractor consult in patients with documented CED infection. (COR ; LOE ) At least 2 sets of blood cultures before antibiotics for suspected CED infection. (COR ; LOE C-LD) Additional imaging to diagnose pocket or lead infection. (COR b; LOE C-LD) New infection management decision trees can support diagnosis and treatment. Shared decision-making Discuss risks of abandonment versus risks of extraction with patients. (COR ; LOE ) Extraction may be considered after shared decision-making process with patients. (COR b; LOE ) Discuss program and operator volume, clinical success, and complication rates with patients. (COR ; LOE ) CED management When preparing for CED upgrade, a preparatory venogram or noninvasive ultrasound prior to opening the pocket to assess venous patency should be considered. Leave abandoned leads in a condition that permits future extraction. (COR ; LOE ) ncrease surveillance for leads with higher failure rates. (COR a; LOE ) 4

Occlusive compliant balloon Deployment of a compliant occlusion balloon for SVC tears to help control severity of bleeding. Preprocedural preparation: Place a stiff guidewire and insert an introducer sheath. nitial studies have suggested that the occlusive balloon is safe and associated with improved survival in the setting of vascular tears of the SVC. 5

Treatment Lead survival Recommendation COR LOE A lead model and clinical scenario-specific strategy of increased surveillance and management can be useful for CED leads that have been identified with higherthan-expected failure rates. a Existing CED lead management Recommendations COR LOE Leaving the lead in a condition that will permit future extraction and prevents retraction into the vessel is recommended for any abandoned lead. Careful consideration with the patient on the decision on whether to abandon or remove a lead is recommended before starting the procedure. The risks and benefits of each course of action should be discussed, and any decision should take the patient s preference, comorbidities, future vascular access, and available programming options into account. Lead abandonment or removal can be a useful treatment strategy if a lead becomes clinically unnecessary or nonfunctional. a B-NR 6

CED infection Recommendations COR LOE Evaluation by physicians with specific expertise in CED infection and lead extraction is recommended for patients with documented CED infection. f antibiotics are going to be prescribed, drawing at least 2 sets of blood cultures before starting antibiotic therapy is recommended for all patients with suspected CED infection to improve the precision and minimize the duration of antibiotic therapy. Gram stain and culture of generator pocket tissue and the explanted lead(s) are recommended at the time of CED removal to improve the precision and minimize the duration of antibiotic therapy. Preprocedural transesophageal echocardiography is recommended for patients with suspected systemic CED infection to evaluate the absence or size, character, and potential embolic risk of identified vegetations. Transesophageal echocardiography can be useful for patients with CED pocket infection with and without positive blood cultures to evaluate the absence or size, character, and potential embolic risk of identified vegetations. a C-LD C-LD B-NR B-NR 7

Treatment CED infection Recommendations COR LOE Evaluation by physicians with specific expertise in CED infection and lead extraction can be useful for patients with suspected CED infection. Additional imaging may be considered to facilitate the diagnosis of CED pocket or lead infection when it cannot be confirmed by other methods. A complete course of antibiotics based on identification and in vitro susceptibility testing results after CED removal is recommended for all patients with definite CED system infection. Complete device and lead removal is recommended for all patients with definite CED system infection. Complete removal of epicardial leads and patches is recommended for all patients with confirmed infected fluid (purulence) surrounding the intrathoracic portion of the lead. Complete device and lead removal is recommended for all patients with valvular endocarditis without definite involvement of the lead(s) and/or device. a b C-LD B-NR B-NR B-NR 8

CED infection Recommendations COR LOE Complete device and lead removal is recommended for patients with persistent or recurrent bacteremia or fungemia despite appropriate antibiotic therapy and no other identifiable source for relapse or continued infection. Careful consideration of the implications of other implanted devices and hardware is recommended when deciding on the appropriateness of CED removal and for planning treatment strategy and goals. B-NR Delayed, inappropriate, or incomplete therapy can result in significant morbidity and mortality for patients with CED infection. 1 - Fred M. Kusumoto, M.D. 9

Treatment Risk factors for CED infection Patient-related factors Age Chronic kidney disease Hemodialysis Diabetes mellitus Heart failure Chronic obstructive pulmonary disease Preprocedure fever Malignancy Skin disorder mmunosuppressive drug Prior CED infection Anticoagulation Procedure-related factors Pocket reintervention (generator change, upgrade, lead or pocket revision) Pocket hematoma Longer procedure duration nexperienced operator CD (compared with PM) Lack of use of prophylactic antibiotics Microbe-related factors Highly virulent microbes (e.g., staphylococci) 10

ndications for lead extraction (noninfectious) Recommendations COR LOE Device and/or lead removal can be useful for patients with severe chronic pain at the device or lead insertion site or believed to be secondary to the device, which causes significant patient discomfort, is not manageable by medical or surgical techniques, and for which there is no acceptable alternative. Lead removal is recommended for patients with clinically significant thromboembolic events attributable to thrombus on a lead or a lead fragment that cannot be treated by other means. Lead removal is recommended for patients with SVC stenosis or occlusion that prevents implantation of a necessary lead. Lead removal is recommended for patients with planned stent deployment in a vein already containing a transvenous lead, to avoid entrapment of the lead. Lead removal as part of a comprehensive plan for maintaining patency is recommended for patients with SVC stenosis or occlusion with limiting symptoms. a 11

Treatment ndications for lead extraction (noninfectious) Recommendations COR LOE Lead removal can be useful for patients with ipsilateral venous occlusion preventing access to the venous circulation for required placement of an additional lead. Lead removal is recommended for patients with life-threatening arrhythmias secondary to retained leads. Lead removal can be useful for patients with a CED location that interferes with the treatment of a malignancy. Lead removal can be useful for patients if a CED implantation would require more than 4 leads on one side or more than 5 leads through the SVC. Lead removal can be useful for patients with an abandoned lead that interferes with the operation of a CED system. Lead removal may be considered for patients with leads that due to their design or their failure pose a potential future threat to the patient if left in place. a a a a b C-LD C-LD C-LD 12

ndications for lead extraction (noninfectious) Recommendations COR LOE Lead removal may be considered for patients to facilitate access to MR. Lead removal may be considered in the setting of normally functioning nonrecalled pacing or defibrillation leads for selected patients after a shared decision-making process. b b 13

Periprocedural management: preparatory phase Perform a comprehensive history and physical exam Perform anticoagulation management Optimize hemodynamics Confirm the appropriate indications for extraction Perform the CED interrogation ndicate lead model numbers, noting any lead that requires special consideration Confirm lead implant dates dentify prior abandoned leads and implant dates Assess pacemaker dependency Turn off rate-adaptive programming Obtain the preprocedural imaging when clinically appropriate. Options include the following: Chest radiography (both posteroanterior and lateral) to assess lead position, identify the presence of abandoned leads, and confirm lead type Echocardiogram to assess LV function, identify intracardiac masses/vegetations, evaluate valve function and whether a patent foramen ovale is present, and identify intracardiac lead course and presence of pleural or pericardial effusions Cardiac CT to assess extravascular or extracardiac lead positioning and potentially identify sites of venous adhesions Fluoroscopy to identify sites of venous occlusion or stenosis and assess regions of lead mobility and adherence 14

Define the extraction approach and procedure goals Percutaneous versus open extraction Hybrid approach to the extraction Goal of single versus multiple lead removal or complete system removal Minimizing damage to nontargeted leads Determine the postextraction plan ndications for CED reimplantation Timing of CED reimplantation Obtain the patient s informed consent Outcomes and follow-up Recommendation COR LOE Extraction programs and operatorspecific information on volume, clinical success rates, and complication rates for lead removal and extraction should be available and discussed with the patient prior to any lead removal procedure. 15

Patient clinical scenarios Patient scenario # 1 A 52-year-old man with a history of complete heart block, leading to a diagnosis of cardiac sarcoidosis, underwent dual-chamber CD with a single-coil CD lead 4 years ago. He has had ATP therapy for VT. Remote interrogation shows impedance of 150 and episodes of noise on RV lead. Noise is reproducible on exam with pocket manipulation. Management strategies Management options discussed included addition of new RV pace-sense lead; and CD lead extraction and replacement. Values elicited during discussion included his desire for a reliable system, concerns about the effect of more leads in his vasculature, and his desire to be able to easily undergo MR in the future. The decision was made to extract and reimplant a new CD lead. Key points Should the strategy of an additional lead be applied, vein patency would need to be considered. n case of extraction and reimplantation, the lead s original insertion point would need to be evaluated in case this represents damage from the costoclavicular ligaments. Adding a pace-sense lead is sometimes a suboptimal choice, because the CD shock coil can also be at high risk of failure in the setting of a pace-sense component fracture. 16

Patient scenario # 2 An 86-year-old man with complete heart block who underwent dual-chamber pacemaker implantation 14 years ago, with most recent generator replacement 3 years ago. Two leads are in place. His medical history is significant for chronic lymphocytic lymphoma and recently diagnosed prostate cancer. He presents with noise on the right ventricular lead and inhibition of ventricular pacing consistent with lead malfunction. Management strategies Assess possibility of reprogramming to unipolar. Consider likelihood of ipsilateral venous occlusion, which would require contralateral lead placement for addition. Management options discussed included extraction of 14-year-old pacemaker lead with new lead implantation versus abandonment of old lead and placement of new right ventricular lead. Values elicited in discussion included patient s desire to avoid hospitalization and not wanting to be dependent on his children. Although the risks of lead addition and lead extraction are comparable in the literature, the risk of major complications and a more prolonged hospital stay appear higher for an extraction procedure, particularly given the patient s advanced age, comorbidities, and older leads. The decision was made to add a new pace-sense lead and abandon the previously placed lead. Key points Age and medical comorbidities contribute to the lead management decision-making. Lead type and dwell time contribute to the risk and benefit analysis in lead management decision-making. Abandoned leads are a contraindication for MR, which is often used in the follow-up of cancer. 17

Patient clinical scenarios Patient scenario # 3 A 46-year-old woman with a history of mechanical mitral valve replacement complicated by complete heart block, who underwent placement of a dual-chamber pacemaker 3 years ago. She presents with dislodgement of the atrial lead associated with symptoms of loss of AV synchrony. Management strategies Management options discussed included extraction and replacement of atrial lead, attempt to reposition, and addition of new atrial lead. Values elicited in discussion included the desire to have the best possible functional CED system and not have abandoned leads, even if this resulted in a longer hospital stay due to anticoagulation management. Despite the mechanical mitral valve, the ease of extraction of a 3-year-old pacemaker lead is reasonable. The decision was made to extract and replace the lead. Key points Young age and long-term need for functional CED therapy and the desire to avoid an abandoned lead contributed to the decision-making process. 18

Patient scenario # 4 A 25-year-old man who underwent a secondary prevention CD placement with a dual-coil lead 14 years ago for a ventricular fibrillation cardiac arrest. His CD lead fractured 6 years ago, and he underwent addition of a new CD lead and abandonment of his first CD lead. During the follow-up, the new CD lead was found to be fractured, with inappropriate detections due to noise. Management strategies Management options discussed included adding a third lead; abandoning both transvenous CD leads and implanting a subcutaneous CD; extracting both leads and adding a new CD lead; extracting both leads and implanting a subcutaneous CD. Primary concerns elicited were the potential for long-term complications from the CD leads and the possibility of needing an MR in his lifetime. The decision was made to extract both leads and implant a subcutaneous CD lead, after discussing the risks and benefits of a subcutaneous CD system versus a transvenous CD system. Key points The lead extraction procedure was higher risk due to the previous decision to abandon a malfunctioning lead in a young patient. 19

Patient clinical scenarios Patient scenario # 5 A 40-year-old woman with familial LQT2 who underwent primary prevention CD placement with a dual-coil lead 8 years ago due to pregnancy, concerns about increased risk of arrhythmias during the postpartum setting, and strong family history of peripartum sudden death. She has two children, will not have future pregnancies, and has never had CD therapies. CD generator is ER, and she no longer wants CD therapy. Management strategies Management options discussed included abandoning lead and generator; removing generator and abandoning lead; and extracting lead and generator. Values elicited included a desire to not have a prolonged hospitalization or recovery and not wanting a generator in the pocket. The patient did not want to undergo extraction. At her request, the decision was made to remove the generator and abandon the lead. Key points The option of removing only the generator would leave the patient with a contraindication for MR. The patient remains at ongoing risk for lead infection, which would require a higher risk extraction in the future. Opening the pocket to remove the generator exposed the patient to a risk of infection. 20

Lead extraction procedurerelated complications Procedure ncidence % Major 0.19%-1.80% Death 0.19%-1.20% Cardiac avulsion 0.19%-0.96% Vascular laceration 0.16%-0.41% Respiratory arrest 0.20% Cerebrovascular accident 0.07%-0.08% Pericardial effusion requiring intervention 0.23%-0.59% Hemothorax requiring intervention 0.07%-0.20% Cardiac arrest 0.07% Thromboembolism requiring intervention 0.07% Flail tricuspid valve leaflet 0.03% requiring intervention Massive pulmonary embolism 0.08% Minor 0.60%-6.20% Pericardial effusion without intervention 0.07%-0.16% Hematoma requiring evacuation 0.90%-1.60% Venous thrombosis requiring 0.10%-0.21% medical intervention Vascular repair at venous entry site 0.07%-0.13% Migrated lead fragment without sequelae 0.20% Bleeding requiring blood transfusion 0.08%-1.00% AV fistula requiring intervention 0.16% Coronary sinus dissection 0.13% Pneumothorax requiring chest tube 1.10% Worsening tricuspid valve function 0.32%-0.59% Pulmonary embolism 0.24%-0.59% 21

nfection diagnosis and treatment Figure 1. Management of suspected CED infection Suspected CED infection: pocket or systemic Blood cultures nfectious disease consultation Positive blood cultures or prior antibiotic treatment Transesophageal echocardiography Valve vegetation Lead vegetation Negative TEE CED removal Antibiotics 4-6 weeks* CED removal Antibiotics 2-4 weeks* Consider CED removal depending on microbiology Antibiotics 2 weeks* Reimplant CED when blood cultures are negative for at least 72 hours (duration can be longer depending on clinical scenario), and CED remains indicated 22

Negative blood cultures Transesophageal echocardiography if concern for systemic infection Positive Negative Evidence of pocket infection or erosion** Yes No CED removal Antibiotics 2 weeks* Close observation Reimplant CED with specific timing dependent on clinical scenario, and if CED remains indicated *Refer to text and table for specific recommendations depending on microbiology. Antimicrobial therapy should be at least 4-6 weeks for endocarditis (4 weeks for native valve, 6 weeks for prosthetic valve or staphylococcal valvular endocarditis). f lead vegetation is present in the absence of a valve vegetation, 4 weeks of antibiotics for Staphylococcus aureus and 2 weeks for other pathogens is recommended. **2010 AHA CED nfection Update distinguishes between pocket infection and erosion (Baddour et al. Circulation 2010;121:458-477). Usually the contralateral side; a subcutaneous CD may also be considered. 23

nfection diagnosis and treatment Figure 2. Management of suspected pocket infection Suspected CED pocket infection Early superficial site infection: Erythema and/or stitch abscess localized to superficial aspect of the wound, within the first 30 days of device placement, without fever or systemic toxicity Course of oral antibiotics* Pathogen-directed antimicrobial therapy 2 weeks (pocket culture) Pathogen-directed antimicrobial therapy 4 weeks for Staphylococcus aureus, 2 weeks for other pathogens Pathogen-directed antimicrobial therapy 4-6 weeks (4 weeks for native valve, 6 weeks for prosthetic valve staphylococcal valvular endocarditis) beginning after CED removal 24

CED pocket infection: Pocket discomfort, redness, swelling or purulent drainage, percutaneous exposure of the device generator and/or leads, with or without fever or systemic toxicity Failed therapy Blood cultures Transesophageal echocardiography CED removal, including generator and all transvenous leads Negative blood cultures Positive blood cultures Positive TEE *See full text of the consensus statement for examples. 25

nfection diagnosis and treatment Figure 3. Management of bacteremia without evidence of CED infection Bacteremia without evidence of CED infection* nfectious disease consultation Take out all easily removable non-ced sources of infection such as intravenous lines No identifiable source of infection or continued clinical concern or evidence for CED infection? Yes Alpha-hemolytic Streptococcus spp. Beta-hemolytic Streptococcus spp. Enterococcus spp. Staphylococcus aureus CoNS Propionibacterium spp. Candida spp. CED removal Gram-negative bacteria Pneumococci Observation without CED removal CED removal if recurrent or continued bacteremia despite appropriate antibiotic therapy CED removal or observation without lead removal CED removal if recurrent or continued bacteremia despite appropriate therapy 26

Abbreviations ATP AV CED COR Cr CRP CT EGM ER ESRD CD NR LOE LV MR PM RV SVC TEE VT Antitachycardia pacing Atrioventricular Cardiovascular implantable electronic device Class of recommendation Creatinine C-reactive protein Computed tomography Electrogram Elective replacement indicator End-stage renal disease mplantable cardioverter defibrillator nternational normalized ratio Level of evidence Left ventricle Magnetic resonance imaging Pacemaker Right ventricle Superior vena cava Transesophageal echocardiography Ventricular tachycardia *mportant to distinguish between bloodstream infection and contamination in bacteremia involving skin flora. References 1. Kusumoto et al. 2017 HRS Expert Consensus Statement on Cardiovascular mplantable Electronic Device Lead Management and Extraction. Heart Rhythm, 2017. 2. Wilkoff, B.L., et al. (2009). Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA). Heart Rhythm, 6(7), 1085-1104. 27

2018 Spectranetics. All rights reserved. Approved for external distribution. D040224-01 032018 2018 Koninklijke Philips N.V. All rights reserved. Some or all products manufactured by Spectranetics, a Philips company. Approved for external distribution. D040224-01 032018 28