Integra. Proximal Humeral Fracture Plate System SURGICAL TECHNIQUE

Similar documents
Surgical Technique. Proximal Humerus Locking Plate

Integra. DigiFuse Cannulated Intramedullary Fusion System SURGICAL TECHNIQUE

AcUMEDr. Locking Proximal Humeral Plate. PoLARUSr PHPt

Proximal Humerus Plating System. Surgical Technique TRAUMA

Technique Guide. 3.5 mm LCP Periarticular Proximal Humerus Plate. Part of the Synthes locking compression plate (LCP) system.

Technique Guide Small Bone Fusion System

Integra SURGICAL TECHNIQUE. MemoFix Super Elastic Nitinol Staple System. Super Elastic Nitinol Staple System

Conventus CAGE PH Surgical Techniques

Lapidus Arthrodesis System Instructions for Use

Surgical Technique Guide PANTERA. Proximal Humerus Fracture Fixation Plate System

TABLE OF CONTENTS. 2 (8144 Rev 2)

Pinit Plate Small Bone Fusion System Bone Plate & Screw System

Zimmer Periarticular Proximal Humeral Locking Plate

Surgical Technique. Clavicle Locking Plate

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

SMV Scientific Bone Plate and Screw System Surgical Technique

Humeral SuturePlate. Surgical Technique

Surgical Technique. 3.5mm and 4.5mm Lateral Proximal Tibia Locking Plates

Surgical Technique. Anterolateral and Medial Distal Tibia Locking Plates

Flexible Fragment Fixation. Surgical Technique

Surgical Technique. Olecranon Locking Plate

Technique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

AcUMEDr. LoCKING CLAVICLE PLATE SYSTEM

Surgical Technique. Locking Small Fragment Overview

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

System. Humeral Nail. Surgical Technique

PediLoc 3.5mm and 4.5mm Contour Femur Plate Surgical Technique

Surgical Technique. Calcaneal Locking Plate

Surgical Technique International Version. Clavicle Locking Plate

Surgical Technique. Distal Humerus Locking Plate

3.5 mm LCP Clavicle Hook Plates

Open reduction; plate fixation 1 Principles

Integra. ADVANSYS Plating System SURGICAL TECHNIQUE

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

WINSTA-C. Clavicle Plating System

Surgical Technique. Targeter Systems Overview

Integra. Silicone PIP Implant SURGICAL TECHNIQUE

Surgical Technique. Lower Extremity Plates and Straight Plates

Technique Guide. PHILOS and PHILOS Long. The anatomic fixation system for the proximal humerus.

3.5 mm LCP Olecranon Plates

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System.

Technique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system.

BICEPTOR Tenodesis System

Mandible External Fixator II. Provides treatment for fractures of the maxillofacial area.

Low Bend Distal Tibia Plates

Correction System. Surgical Technique

Surgical Technique. Cannulated Angled Blade Plate 3.5 and 4.5, 90

Integra. Titan Modular Shoulder System, 2.5

3.5 mm LCP Extra-articular Distal Humerus Plate

For the Attention of the Operating Surgeon: IMPORTANT INFORMATION ON THE MATRIXRIB FIXATION SYSTEM

3.5 mm Locking Attachment Plate

wave Calcaneal Fracture Plate

The Locking Calcaneal Plate Instrument and Implant Sets

MetaFix Ludloff Plate

OBSOLETED. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

PediLoc 3.5mm and 4.5mm Bowed Femur Plate Surgical Technique

3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments

Small Fragment Plating System. Securing optimal fixation through locked and compression plating technology

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

Small Fragment Plating System

Technique Guide Lapidus Arthrodesis System

3.5 MM VA-LCP PROXIMAL TIBIA PLATE SYSTEM

3.5 mm Clavicle Hook Plates

Surgical Technique International Version

Cannulated Angled Blade Plate 3.5 and 4.5, 90.

Olecranon Osteotomy Nail. For simple fractures and osteotomies of the olecranon.

AxSOS Locking Plate System

Technique Guide KISSloc Suture System

Surgical Technique Carpal Fusion

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

TM TM Surgical Technique

OptiLock Periarticular Plating System For Distal Tibial Fractures. Surgical Technique

LCP Distal Humerus Plates

Instrument and Implant for wrist fracture

Zimmer Anterior Buttress Plate System. Surgical Technique

Technique Guide. 3.5 mm LCP Proximal Tibia Plate. Part of the Synthes Small Fragment LCP System.

Low Profile Neuro Plating System. Surgical Technique

DYNAMIC, TRANSVERSE COMPRESSION. Low Profile, Anatomic Design, Type II Anodized. Mechanical Compression Designed to Stimulate the Fusion Process

OPERATIVE TECHNIQUE GALAXY FIXATION SHOULDER

P.R.C.T II FIXATION PLATE FOR ARTICULAR FRACTURE OF THE PROXIMAL HUMERUS SURGICAL TECHNIQUE

Technique Guide. 2.7 mm/3.5 mm LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.

Zimmer Small Fragment Universal Locking System. Surgical Technique

Distal Ulnar Locking Plate

Locking Ankle Plating System. Surgical Technique

TORNIER BIO-RSA. Bony Increased Offset - Reversed Shoulder Arthroplasty SURGICAL TECHNIQUE

Polarus 3 Solution Plates and Nails

Integra. surgical technique. Advansys Midfoot Plating System. eng. D.L.P. Dorsal Lisfranc Plate. M.L.P. Medial Lisfranc Plate

Locking Proximal Humerus Plate. For complex and unstable fractures.

NCB Proximal Humerus Plating System

3.5 mm LCP Superior Anterior Clavicle Plates

DEVELOPED BY MEDSHAPE, INC. IN CONJUNCTION WITH PATRICK ST. PIERRE, M.D. BICEPS TENODESIS ARTHROSCOPIC AND SUBPECTORAL SURGICAL TECHNIQUE

LCP Distal Tibia Plate

Integra. Spider and Mini Spider Limited Wrist Fusion System SURGICAL TECHNIQUE

Zimmer MIS Periarticular 3.5mm Proximal Tibial Locking Plate

BIOKNOTLESSRC ROTATOR CUFF REPAIR SUTURE ANCHOR SURGICAL TECHNIQUE. Surgical Technique for Arthroscopic Rotator Cuff Repair. Raymond Thal, M.D.

LCP Low Bend Medial Distal Tibia Plates 3.5 mm. Anatomic plates with low profile head for intra- and extraarticular fractures.

Surgical Technique Guide

Transcription:

Integra Proximal Humeral Fracture Plate System SURGICAL TECHNIQUE

Table of Contents Introduction Product Description... 2 Indications... 3 Contraindications... 3 Warnings and Precautions... 4 Design Rationale LP (Low Profile) Plate... 5 (Greater Tuberosity) Plate... 6 LP Plate Surgical Technique Step 1: Patient Positioning... 7 Step 2: Exposure... 7 Step 3: Fracture Reduction and Debridement... 7 Step 4: Plate Positioning... 8 Step 5: Proximal 3.5mm Screw Insertion... 9 Step 6: 3.5mm Shaft Screw Insertion... 10 Step 7: Final Verification... 11 Plate Surgical Technique Step 1: Patient Positioning... 12 Step 2: Exposure... 12 Step 3: Fracture Reduction and Debridement... 12 Step 4: Plate Positioning... 13 Step 5: Proximal 3.5mm Screw Insertion... 14 Step 6: 2.7mm Proximal Holes ( Plate Only)... 15 Step 7: 3.5mm Shaft Screw Insertion... 16 Step 8: Final Verification... 17 Product Information... 18 Instrumentation... 19

Surgical Technique As the manufacturer of this device, Integra does not practice medicine and does not recommend this or any other surgical technique for use on a specific patient. The surgeon who performs any implant procedure is responsible for determining and using the appropriate techniques for implanting the device in each patient. Introduction Joseph Abboud, MD Philip Duke, MB.BS, FRACS, FA(ORTH)A William Geissler, MD Anand Murthi, MD Mark Ross, MB.BS, FRACS, FA (ORTH)A Caution: Federal law restricts this device to sale by or on the order of a physician or practitioner. Product Description The Integra Proximal Humeral Fracture Plate System is composed of left and right Humeral reconstruction plate implants in two options, Plate and LP Plate. The plate is designed to cover the greater tuberosity and is available in four-hole (91mm) and seven-hole (115mm), and ten-hole (138mm) lengths or sizes. The LP plate is designed to sit lower on the greater tuberosity and is available in three-hole (88mm), six-hole (112mm), and nine-hole (135mm) lengths or sizes. The system will feature 3.5mm locking screws (15-75mm lengths), non-locking compression screws (15-40mm lengths) and non-locking partial thread lag screws (40-75mm lengths)., In addition to, 2.7mm locking screws (10-25mm lengths) are also available. The Integra Proximal Humeral Fracture Plate is a single component made from stainless steel (SS 316L). The non-locking compression, locking and non-locking partial thread lag screws are made from stainless steel (SS 316L). 2

Indications The Integra Proximal Humeral Fracture Plate system is designed for fractures and fracture dislocations, osteotomies and non-unions of the proximal humerus. Indications Include: Dislocated two-, three-, and four-fragment fractures of the proximal humerus, including fractures involving osteopenic bone Pseudoarthroses in the proximal humerus Osteotomies in the proximal humerus Contraindications Not indicated for use with acute infections or for children during the growth phase Screws are contraindicated in: active infection, conditions which tend to retard healing such as blood supply limitations, previous infections, insufficient quantity or quality of bone to permit stabilization of the fracture complex, conditions that restrict the patient s ability or willingness to follow postoperative instructions during the healing process and foreign body sensitivity. Cases with malignant primary or metastatic tumors which preclude adequate bone support or screw fixations, unless supplemental fixation or stabilization methods are utilized. Foreign body sensitivity where material sensitivity is suspected, appropriate tests should be made and sensitivity ruled out prior to implementations. These implants are intended as a guide to normal healing, and are NOT intended to replace normal body structure or bear the weight of the body in the presence of incomplete bone healing. Delayed unions or non-unions in the presence of load bearing or weight bearing might eventually cause the implant to break due to metal fatigue. All metal surgical implants are subjected to repeated stress in use, which can result in metal fatigue. 3

Warnings and Precautions No metallic surgical implant should be reused. Any metal implant, once used, should be discarded. Even though it appears undamaged, it may already have small defects and internal stress patterns which may lead to fatigue failure. Correct handling of implant is extremely important. Avoid contouring metallic implants whenever possible. If necessary, or allowed by design, the device should not be bent sharply, reverse bent, notched or scratched. All of these operations can produce defects in the surface finish and internal stress concentrations, which may become the focal point for eventual failure of the appliance. If metal plates or other metallic devices are to be used together with the Integra Proximal Humeral Fracture Plates, all such devices should be manufactured from a metal that has a similar composition to avert possibility of galvanic corrosion or other metallic reactions. Correct selection of the implant is extremely important. The potential for success in fracture fixation is increased by the selection of the proper size of the implants. The patient s anatomy and indication will determine the size of the Integra Proximal Humeral Fracture Plate to be used. The size of the human bones presents limiting restrictions on the size and strength of implants. Postoperative care is extremely important. The patient must be warned that noncompliance with postoperative instructions could lead to breakage of the implant requiring revision surgery to remove the device. The use of Integra Proximal Humeral Fracture Plates provides the surgeon a means of bone fixation and helps generally in the management of fractures and reconstructive surgeries. The implants are intended as a guide to normal healing and are NOT intended to replace normal body structure. All metal surgical implants are subject to repeated stress in use which can result in metal fatigue. Failure to immobilize a delayed union or nonunion of bone will result in excessive and repeated stresses which are transmitted by the body to any temporary internal fixation device prior to the healing of the fracture. Due to normal metal fatigue, these stresses can cause eventual bending or breakage of the device. Therefore, it is important that immobilization of the fracture site is maintained until firm bony union (confirmed by clinical and roentgenographic examination) is established. Detailed written instructions on the use and limitations of the device should be given to the patient. While the surgeon must make the final decision on implant removal, whenever possible and practical for the individual patient, fixation devices should be removed once their service as an aid to healing is accomplished, particularly in younger more active patients. The MR environment presents risks to patients with metal implant. Review of the available literature documents that metal implants may heat resulting in tissue damage and may migrate out of position. They may also cause artifact affecting image quality. Physicians should take these risks into consideration when recommending MRI imaging for patients with metal implants. Note: The Integra Proximal Humeral Fracture Plate System has not been evaluated for safety and compatibility in the MR environment. The Integra Proximal Humeral Fracture Plate System has not been tested for heating or migration in the MR environment. 4

Design Rationale LP (Low Profile) Plate Designed to sit lower on the greater tuberosity to minimize subacromial impingement 9 proximal screw options 4 calcar screws to provide inferior medial support Slotted screw option for initial plate positioning Anatomic fit with right and left plates and different length plates 3-hole (89mm) 6-hole (112mm) 9-hole (135mm) 6 suture holes for tuberosity fixation Easy in-situ needle passing through angled and scalloped holes Also used as wire holes for initial plate fixation Multiple Screw Options 3.5mm Locking, Non-Locking and Lag Screw Options 5

Design Rationale (Greater Tuberosity) Plate Maximizes tuberosity coverage and humeral head bone purchase with 12 proximal screw options 4 calcar screws to provide inferior medial support Anterior tab for initial plate positioning and buttress option Anatomic fit with right and left plates and different length plate 4-hole (91mm) 7-hole (116mm) 10-hole (140mm) 5 suture holes for soft tuberosity fixation Easy in-situ needle passing through angled and scalloped holes Also used as wire holes for initial plate fixation Multiple Screw Options 2.7mm Proximal Locking Screws 3.5mm Locking, Non-Locking and Lag Screw Options 6

Surgical Technique: LP (Low Profile) Plate Step 1: Patient Positioning 1-1 Place the patient in beach chair position (1-1). Ensure that the involved shoulder extends laterally over the top corner of the table so that the arm can be brought into extension and abduction (this is essential for good exposure of the proximal humerus). 1-1 Step 2: Exposure 2-1 Deltopectoral Approach Exposure is achieved through a 10-12cm incision that starts at the clavicle and proceeds over the coracoid toward the deltoid insertion. The incision should be in line with the deltoid-pectoral interval. Once the initial incision is made, develop the subcutaneous flap, locate and identify the cephalic vein. Gently retract the cephalic vein either laterally with the deltoid muscle or medially with the pectoralis major. Self-retaining retractors can be utilized to achieve this exposure. Release the fascia along the lateral border of the coracobrachialis and gently retract it medially. To help improve visualization and reduction find the pectoralis insertion and release the proximal third of the pectoralis tendon to expose the biceps. Take care to protect the biceps tendon which lies directly underneath. Step 3: Fracture Reduction and Debridement 3-1 Debride the fracture and keep any bone pieces to aid in the repair. After debridement of the fracture, reduction can be achieved by manual traction and indirect manipulation. Reduction clamps are also available in the tray. In cases of severe comminution reduction of the tuberosities can be achieved by suturing the rotator cuff together. To aid in healing, bone graft should be considered to fill any voids. 7

Step 4: Plate Positioning 4-1 Select the appropriate Integra Proximal Humeral plate, left or right, LP plate (4-1) in the appropriate length to stabilize the fracture. The LP plate is designed to sit lower on the proximal humerus which can help to prevent acromial impingement but does not allow full buttress of the greater tuberosity. 4-1 The LP plate is placed onto the humerus approximately 2cm distal to the rotator cuff attachment on the upper part of the greater tuberosity and 2-3mm lateral to the bicipital groove. Temporarily fix the plate with 2.0mm guide wires. 4-2 Place a PF Pin in the center of the slot on the plate(4-2). This will allow the plate to be translated up or down to achieve desired plate position. Once desired plate positioning has been achieved proceed with proximal screw insertion. 4-2 LP LP 8

Step 5: Proximal 3.5mm Screw Insertion Note: It is recommended to start with the screws that angle up into the head to secure the reduced humeral head fragments. 5-1 Place the appropriate LP Proximal Hole Targeting Guide onto the plate. Lock the targeting guide into place by inserting the 2.4mm Locking Drill Guide into the most proximal hole on the guide (5-1). 5-1 LP 5-2 Using the 2.4mm Drill Sleeve inside the 3.5mm Screw Guide place the guide into one of the four proximally angled holes on the targeting guide (5-2). Drill using the 2.4mm drill until resistance is felt. Use fluoroscopy to verify the tip of the drill is close to the subchondral bone. 5-2 Note: Care should be taken to ensure the subchondral bone is not penetrated. LP 5-3 Use the depth readings on the drill to determine screw length (close up of drill in drill guide showing laser marks on drill). The Standard Depth Gauge can be used at this point if necessary (5-3). Remove the drill and 2.4mm Drill Sleeve leaving the 3.5mm Screw Guide in place. 5-3 LP 9

5-4 Insert the determined length locking, non-locking compression, or non-locking partial thread 3.5mm screw through the Screw Guide using the TX15 Driver Shaft and Ratcheting Driver Handle (5-4). Repeat the above steps for the remaining angled screw holes on the targeting guide before proceeding to the additional proximal screw holes. 5-4 LP Step 6: 3.5mm Shaft Screw Insertion The shaft of the plate can be secured by either locking screws or multidirectional non-locking screws. 6-1 Locking Screws Thread the 2.4mm Locking Drill Guide into the most proximal shaft hole. Drill using the 2.4mm Drill until the far cortex is penetrated). Use the markings on the drill to determine screw length or remove the drill guide and use the Standard Depth Gauge (6-1a). 6-1a If power is used to insert the screw, use of a torque limiter is recommended. Start the power tool slowly, increase the speed and then reduce it again before the screw is fully tightened. Final tightening of Locking Screws should always be performed manually using a two finger tighten technique to prevent over-tightening of Locking Screws. Insert the corresponding 3.5mm locking screw using the TX15 Driver Shaft and Ratcheting Driver Handle (6-1b). Repeat for the remaining shaft holes ensuring the plate stays aligned with the humeral shaft as you work distally. 6-1b LP Note: Use of a torque limiter is required if inserting screws under power. Do not lock the screws under power as this risks damaging the screw recess, making implant removal difficult. LP 10

6-2 Non-Locking Compression Screws Place the 2.4mm drill sleeve into the 3.5mm Screw Guide, insert in the desired screw orientation and drill using the 2.4mm drill until the desired depth is achieved (6-2a). Use the Standard Depth Gauge to determine screw length (6-2b). 6-2a Insert the corresponding 3.5mm non-locking compression screw using the TX15 Driver Shaft and Ratcheting Driver Handle (6-2c). Repeat for the remaining shaft holes ensuring the plate stays aligned with the humeral shaft as you work distally. 6-2b LP LP 6-2c LP Step 7: Final Verification 7-1 Using Fluoroscopy evaluate the humerus to verify proper reduction and screw placement. 11

Surgical Technique: (Greater Tuberosity) Plate Step 1: Patient Positioning 1-1 Place the patient in beach chair position (1-1). Ensure that the involved shoulder extends laterally over the top corner of the table so that the arm can be brought into extension and abduction (this is essential for good exposure of the proximal humerus). 1-1 Step 2: Exposure 2-1 Deltopectoral approach Exposure is achieved through a 10-12cm incision that starts at the clavicle and proceeds over the coracoid toward the deltoid insertion. The incision should be in line with the deltoid-pectoral interval. Once the initial incision is made, develop the subcutaneous flap, locate and identify the cephalic vein. Gently retract the cephalic vein either laterally with the deltoid muscle or medially with the pectoralis major. Self-retaining retractors can be utilized to achieve this exposure. Release the fascia along the lateral border of the coracobrachialis and gently retract it medially. To help improve visualization and reduction find the pectoralis insertion and release the proximal third of the pectoralis tendon to expose the biceps. Take care to protect the biceps tendon which lies directly underneath. Step 3: Fracture Reduction and Debridement 3-1 Debride the fracture and keep any bone pieces to aid in the repair. After debridement of the fracture, reduction can be achieved by manual traction and indirect manipulation. Reduction clamps are also available in the tray. In cases of severe comminution reduction of the tuberosities can be achieved by suturing the rotator cuff together. To aid in healing, bone graft should be considered to fill any voids. 12

Step 4: Plate Positioning 4-1 Select the appropriate Integra Proximal Humeral plate, left or right, plate (4-1) in the appropriate length to stabilize the fracture. The Plate is designed to cover the greater tuberosity and should be utilized in fractures that require additional support or buttress of the greater tuberosity fragments. The plate is placed onto the humerus approximately 6-10mm distal to the rotator cuff attachment on the upper part of the greater tuberosity and 2-3mm lateral to the bicipital groove. Temporarily fix the plate with 2.0mm guide wires. 4-1 4-2 Place a PF Pin in the center of the slot on the plate(4-2). This will allow the plate to be translated up or down to achieve desired plate position. Once desired plate positioning has been achieved proceed with proximal screw insertion. 4-2 13

Step 5: Proximal 3.5mm Screw Insertion Note: It is recommended to start with the screws that angle up into the head to secure the reduced humeral head fragments. 5-1 Place the appropriate Proximal Hole Targeting Guide onto the plate. Lock the targeting guide into place by inserting the 2.4mm Locking Drill Guide into the most proximal hole on the guide (5-1). 5-1 5-2 Using the 2.4mm Drill Sleeve inside the 3.5mm Screw Guide place the guide into one of the four proximally angled holes on the targeting guide (5-2). 5-2 Drill using the 2.4mm drill until resistance is felt. Use fluoroscopy to verify the tip of the drill is close to the subchondral bone. Note: Care should be taken to ensure the subchondral bone is not penetrated. 5-3 5-3 Use the depth readings on the drill to determine screw length (close up of drill in drill guide showing laser marks on drill). The Standard Depth Gauge can be used at this point if necessary (5-3). Remove the drill and 2.4mm Drill Sleeve leaving the 3.5mm Screw Guide in place. 5-4 Insert the determined length locking, non-locking compression, or non-locking partial thread 3.5mm screw through the Screw Guide using the TX15 Driver Shaft and Mini Ratchet Driver Handle (5-4). Repeat the above steps for the remaining angled screw holes on the targeting guide before proceeding to the additional proximal screw holes. 5-4 14

Step 6: 2.7mm Proximal holes ( Plate Only) These four most proximal holes can either be used for suture holes or 2.7mm locking screws or a combination of both to repair the tuberosity. 6-1 Suture Technique Place a heavy non absorbable suture through the tendon at the attachment to the tuberosity and then through the plate (6-1). There is a recess cut out of the back of the plate to allow the passing of suture after the plate is secured. 6-1 Note: Sutures may also be passed prior to the plate being secured for ease of insertion. Tighten the suture until appropriate tension is achieved. 6-2 6-2 2.7mm Screw Technique Thread the 1.9mm Locking Drill Guide into the plate. Drill with the 1.9mm Drill until desired depth is achieved (6-2). Use either the markings on the drill to determine screw length or remove the drill guide and use the Standard Depth Gauge (6-3). Insert the corresponding 2.7mm locking screw using the TX8 Driver Shaft and Mini Ratchet Driver Handle (6-4). Repeat the above steps for the remaining 2.7mm screw holes. 6-3 If power is used to insert the screw, use of a torque limiter is recommended. Start the power tool slowly, increase the speed and then reduce it again before the screw is fully tightened. Final tightening of Locking Screws should always be performed manually using a two finger tighten technique to prevent over-tightening of Locking Screws. Note: Use of a torque limiter is required if inserting screws under power. Do not lock the screws under power as this risks damaging the screw recess, making implant removal difficult. 6-4 15

Step 7: 3.5mm Shaft Screw Insertion The shaft of the plate can be secured by either locking screws or multidirectional non-locking screws. 7-1 Locking Screws Thread the 2.4mm Locking Drill Guide into the most proximal shaft hole. Drill using the 2.4mm Drill until the far cortex is penetrated). Use the markings on the drill to determine screw length or remove the drill guide and use the Standard Depth Gauge (7-1a). 7-1a If power is used to insert the screw, use of a torque limiter is recommended. Start the power tool slowly, increase the speed and then reduce it again before the screw is fully tightened. Final tightening of Locking Screws should always be performed manually using a two finger tighten technique to prevent over-tightening of Locking Screws. Insert the corresponding 3.5mm locking screw using the TX15 Driver Shaft and Mini Ratchet Driver Handle (7-1b). Repeat for the remaining shaft holes ensuring the plate stays aligned with the humeral shaft as you work distally. 7-1b Note: Use of a torque limiter is required if inserting screws under power. Do not lock the screws under power as this risks damaging the screw recess, making implant removal difficult. 16

7-2 Non-Locking Compression Screws Place the 2.4mm drill sleeve into the 3.5mm Screw Guide, insert in the desired screw orientation and drill using the 2.4mm drill until the desired depth is achieved (7-2a). Use the Standard Depth Gauge to determine screw length (7-2b). 7-2a Insert the corresponding 3.5mm non-locking compression screw using the TX15 Driver Shaft and Mini Ratchet Driver Handle (7-2c). Repeat for the remaining shaft holes ensuring the plate stays aligned with the humeral shaft as you work distally. 7-2b 7-2c Step 8: Final Verification 8-1 Using Fluoroscopy evaluate the humerus to verify proper reduction and screw placement. 17

Product Information Screws Plates Catalog Number Description Catalog Number Description 2.7mm Locking Screws HFP0930304RS Humeral Fracture Plate 4-Hole, Right PSS2710LS 2.7mm Locking Screw 10mm HFP0930304LS Humeral Fracture Plate 4-Hole, Left PSS2712LS 2.7mm Locking Screw 12.5mm HFP0930307RS Humeral Fracture Plate 7-Hole, Right PSS2715LS 2.7mm Locking Screw 15mm HFP0930307LS Humeral Fracture Plate 7-Hole, Left PSS2717LS 2.7mm Locking Screw 17.5mm HFP0930310RS Humeral Fracture Plate 10-Hole, Right PSS2720LS 2.7mm Locking Screw 20mm HFP0930310LS Humeral Fracture Plate 10-Hole, Left PSS2722LS 2.7mm Locking Screw 22.5mm PSS2725LS 2.7mm Locking Screw 25mm HFP0930103RS Low Profile Humeral Fracture Plate 3-Hole, Right HFP0930103LS Low Profile Humeral Fracture Plate 3-Hole, Left 3.5mm Locking Screws HFP0930106RS Low Profile Humeral Fracture Plate 6-Hole, Right PSS3515LS 3.5mm Locking Screw 15mm HFP0930106LS Low Profile Humeral Fracture Plate 6-Hole, Left PSS3517LS 3.5mm Locking Screw 17.5mm HFP0930109RS Low Profile Humeral Fracture Plate 9-Hole, Right PSS3520LS 3.5mm Locking Screw 20mm HFP0930109LS Low Profile Humeral Fracture Plate 9-Hole, Left PSS3522LS 3.5mm Locking Screw 22.5mm PSS3525LS 3.5mm Locking Screw 25mm PSS3527LS 3.5mm Locking Screw 27.5mm Single Use PSS3530LS 3.5mm Locking Screw 30mm Catalog Number Description PSS3532LS 3.5mm Locking Screw 32.5mm PSS3535LS 3.5mm Locking Screw 35mm DRL501019 1.9mm Drill Bit PSS3537LS 3.5mm Locking Screw 37.5mm DRL501024 2.4mm Drill Bit PSS3540LS 3.5mm Locking Screw 40mm DRL501035 3.5mm Drill Bit PSS3545LS 3.5mm Locking Screw 45mm WIRE0930501S 2.0mm K-wire Smooth PSS3550LS 3.5mm Locking Screw 50mm WIRE0930501T 2.0mm K-wire Threaded PSS3555LS 3.5mm Locking Screw 55mm PFP501024 2.4mm Provisional Fixation Pin PSS3560LS 3.5mm Locking Screw 60mm 225TXSX002 Disposable Torque Limiter for 3.5mm screws PSS3565LS 3.5mm Locking Screw 65mm 225TXSX001 Disposable Torque Limiter for 2.7mm screws PSS3570LS 3.5mm Locking Screw 70mm PSS3575LS 3.5mm Locking Screw 75mm 3.5mm Compression Screws Instruments PSS3515CS 3.5mm Compression Screw 15mm Catalog Number Description PSS3517CS 3.5mm Compression Screw 17.5mm LDG501019 1.9mm Locking Drill Guide Green PSS3520CS 3.5mm Compression Screw 20mm LDG501024 2.4mm Locking Drill Guide White PSS3522CS 3.5mm Compression Screw 22.5mm DDG501007 2.4mm Drill Guide White PSS3525CS 3.5mm Compression Screw 25mm DDG501008 3.5mm Screw Guide Blue PSS3527CS 3.5mm Compression Screw 27.5mm DDG501009 3.5mm Drill Guide PSS3530CS 3.5mm Compression Screw 30mm 5010009 Torx 15 Drive Shaft PSS3532CS 3.5mm Compression Screw 32.5mm 5010010 Torx 8 Drive Shaft PSS3535CS 3.5mm Compression Screw 35mm PDG501002 Plate Depth Gauge PSS3537CS 3.5mm Compression Screw 37.5mm PDG501003 Drill Guide Depth Gauge PSS3540CS 3.5mm Compression Screw 40mm RM1011S03 Mini Ratchet Driver Handle 3.5mm Partially Threaded Screws 5010001 AO to Trinkle adapter PSS3540PS 3.5mm Partially Threaded Screw 40mm 5010002A Periosteal Elevator PSS3545PS 3.5mm Partially Threaded Screw 45mm 5010008 Bone Reduction Forceps Straight 9 PSS3550PS 3.5mm Partially Threaded Screw 50mm 5010004 Bone Reduction Forceps Curved 8 PSS3555PS 3.5mm Partially Threaded Screw 55mm HTG093003L Left Proximal Hole Targeting Guide Plate PSS3560PS 3.5mm Partially Threaded Screw 60mm HTG093003R Right Proximal Hole Targeting Guide Plate PSS3565PS 3.5mm Partially Threaded Screw 65mm HTG093001L Left Proximal Hole Targeting Guide LP Plate PSS3570PS 3.5mm Partially Threaded Screw 70mm HTG093001R Right Proximal Hole Targeting Guide LP Plate PSS3575PS 3.5mm Partially Threaded Screw 75mm CSA00014 Tray Lid CSA093001 Tray Base CSA093002 Tray Upper CSA093003 Screw Caddy Base CSA093004 Screw Caddy Lid 18

Instrumentation 1 4 2 3 1. Bone Reduction Forceps 2. Left/Right Plates 3. Left/Right LP Plates 4. Bone Reduction Forceps 19

1 3 2 4 5 6 13 8 9 7 10 11 12 1. Smooth/Threaded K-Wires 2. 3.5mm Drill Guide 3. 2.4mm Provisional Fixation Pin 4. 1.9mm/2.4mm Locking and Non-Locking Drill Guides 5. Mini Ratchet Driver Handle 6. Left/Right Hole Targeting Guides 7. Drill Guide Depth Gauge 8. Plate Depth Gauge 9. 1.9mm/2.4mm/3.5mm Drills 10. TORX 8/15 Drive Shafts 11. AO Trinkle Adaptor 12. Elevator 13. Screw Caddy 20

21

22

Integra Proximal Humeral Fracture Plate System Availability of these products might vary from a given country or region to another, as a result of specific local regulatory approval or clearance requirements for sale in such country or region. n Non contractual document. The manufacturer reserves the right, without prior notice, to modify the products in order to improve their quality. n Warning: Applicable laws restrict these products to sale by or on the order of a physician. n Consult product labels and inserts for any indication, contraindications, hazards, warnings, precautions, and instructions for use. For more information or to place an order, please contact: United States, Canada, Asia, Pacific, Latin America USA 800-654-2873 888-980-7742 fax n International +1 609-936-5400 +1 609-750-4259 fax n integralife.com/contact Manufacturer: Ascension Orthopedics, Inc. 11101 Metric Blvd Austin, TX 78758 n USA Integra and the Integra logo are registered trademarks of Integra LifeSciences Corporation or its subsidiaries in the United States and/or other countries. Patent Pending. 2017 Integra LifeSciences Corporation. All rights reserved. Printed in USA. 0M LC-04-0930-0068 Rev. D 0098885-4