TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

Similar documents
TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

ER75 Electro-Acoustic Ear Simulator. Operating Manual

Technical support: +49 (0)7223 /

3. Dimensions, weights Placement and Assembly Pressure drops Noise data Material... 14

Most of the Conductivity/Resistivity electrodes used with the 2850 can be installed into standard 3 /4 in. (NPT or ISO 7-R 3 /4) fittings.

THS74/75 Industrial Temperature & Humidity Transmitter. Operation Manual

The Do s and Don ts of Pressure Transducers

Technical Data Sheet SONOFLOW CO.55 V1.0

Instruction Manual Aerogen, Inc. Part No. AG-AL1010 Rev. C

THE TOTALLY WICKED TORNADO NC CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED TORNADO NC ELECTRONIC CIGARETTE KIT

Cerus P-Series General Specifications Section 15172

PHM-100 PORTABLE HANDHELD TRANSDUCER INDICATOR OPERATORS MANUAL. Transducer Techniques R

NEUROSURGERY LiquoGuard

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0

CABINA S40 USER MANUAL AUDIOMETRIC TEST BOOTH MU2 REV. 1.05

With extended functionality the sensors are also applicable for the detection of air bubbles.

Cyrus soundkey User Instructions Contents

Cyrus soundkey User Instructions Contents

User Manual RECHARGEABLE KIT. Includes: 1 PLUS+ rechargeable pack 2 PLUS+ batteries 1 wall charger 1 USB cable 3 Classic Tobacco flavor tanks

4-20 ma Pressure Transducer

Datasheet BR Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors

HCS70004P, HCS70004G HCS70004C, HCS70004BL HCS70004DP, HCS70004 AEROMIST COLORS NEBULIZER COMPRESSOR KIT. Instruction Manual

MicroSwitcher TMS Series 6, 10, 15, 25 Watt

Signet 2850 Conductivity/Resistivity Sensor Electronics * *

X [dream] Gebrauchsanweisung User manual

RLS /M MX SERIES

Phonak PilotOne II. User Guide

Portable Equine Nebuliser System. User Manual

S202M-K2UC. Miniature Circuit Breaker - S200MUC - 2P - K - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

Off-line filter system

Dr FuelCell Load Measurement Box

INTRAMEDULLARY NAILING TIBIA AND FEMUR 1.3 TIBIAL AND FEMORAL NAILING FEMORAL NAILING WITH RETROGRADE INSERTION IMPLANTS AND OPERATING MANUAL

RLS/E-EV MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES

Fittings & Accessories

Side Channel R ing Blower

CA850 Series 5 Audiometer Operating Manual 3 January, CA850 Series 5. Automatic Audiometer Operating Manual

INTERNATIONAL STANDARD

RLS /M MX SERIES

Multipower. User Guide E S S E N T I A L S T R E N G T H

Low Row. User manual E S S E N T I A L S T R E N G T H

TECH 2 Dew Point Retrofit Kit

Description. Specifications and Ordering Information Proximitor Sensor / interface module/ VDC Housings

There are many varieties of particulate pollutants in our homes and offices. Ones from outside include industrial

RLS /E-EV MX SERIES

ALERT SERVICE BULLETIN Alert Service Bulletin No. 072

Signet 2850 Conductivity/Resistivity Sensor Electronics

E L E C T R O N I C VA P O R I Z E R S. User Manual

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

PROFIBUS Products Overview P PROFIBUS Converter/Repeater P PROFIBUS Gateway P6-3-1

Implant Locator. User Manual

ULTR A SERIES G7-S75

ALERT SERVICE BULLETIN Alert Service Bulletin No. 072 Rev. A

Getting started with Wireless Fitting

RLS /E MX SERIES

ISO INTERNATIONAL STANDARD. Implants for surgery Active implantable medical devices Part 2: Cardiac pacemakers

ULTR A SERIES G7-S13

2YEARS. three-phase kVA. Digital voltage stabiliser Orion Plus. Standard features. Voltage stabilisation PC selectable output voltage

S201-C2. Miniature Circuit Breaker - S200-1P - C - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

TWO STAGE DUAL FUEL BURNERS

Table of Contents. Introduction Indications For Use Contraindications Warnings Precautions...5

3/4" NPT 3080 MF 185-3/4-US 1" NPT 3080 MF US

Sag Shoe Assembly. Instruction Manual # Updated 10/19/2017 Ver. 2.0

Areamaster 250/400 Integrally Ballasted Floodlights 100 W to 400 W HID For hazardous and marine locations.

PL009 Operating Manual

Capacitive Sensors 17

ISO INTERNATIONAL STANDARD

Sterile U Network. Quality Control for Table-top Steam Sterilizers. Introduction: T U T O R I A L S

IECEx Certificate of Conformity CESI

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION

BODYSHAPER P20 OWNER S MANUAL

A m e r i c a s D e n t a l E q u i p m e n t C o m p a n y. Rev 2/15. D a n s e r e a u

Reprocessing Guide. Autoclavable Arthroscope and Hardware Sterilization Tray

Instruction Manual. DSRn. Density & Sound Velocity Transducers

747 Series Stopper Plugs Cable Gland Accessories Flameproof.

ASSEMBLY AUTOMATION FOR PERFECT CANNUL A BONDING

Convex Array Transducer

PORTO 2 VENT CPAP OS. Operator s Manual. PORTO 2VENT CPAP OS System Operator s Manual Part Number Rev I

COPYRIGHT Ramsey Medical, Inc.

Installation Instructions

OWNER S MANUAL and INSTALLATION INSTRUCTIONS

MIE Medical Research Ltd Digital Analyser - Myometer Instruction Manual

WNK5 Series High Precision Pressure Transmitter

Topology... 1-wire Multiplexer, 2-wire 79 1 Multiplexer

LEARNING TO USE YOUR FIRST HEARING AID

CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED ARC 5 ELECTRONIC CIGARETTE KIT.

-SQA-SCOTTISH QUALIFICATIONS AUTHORITY HIGHER NATIONAL UNIT SPECIFICATION GENERAL INFORMATION MARCH

ULTR A SERIES G7-S51

* * Signet 2850 Conductivity/Resistivity Sensor Electronics (PVDF) English. Description. Table of Contents. Dimensions

Gewässer Umwelt Schutz

ULTR A SERIES G7-S23

Tropic plus ultrasonic nebulizer Consumables and Accessories

TECHNICAL BULLETIN. Engine Start Module (ESM) Functional Test. Maxwell Technologies, Inc. June

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

! Caution (continued)

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems

RL/B MZ SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL RL 300/B MZ RL 400/B MZ. 600/ kw 1000/ kw

Goniometer series 400

RLS/M MZ SERIES. Modulating Dual Fuel Burners FIRING RATES DUAL FUEL

TSH Series, 2 Watt. 12 VDC 165 ma 82 % TSH 1212D ±12 VDC ±80 ma 82 % TSH 1215D ±15 VDC ±65 ma 82 % TSH 2405S 5 VDC 400 ma 78 % TSH 2412S 24 VDC ±10%

Transcription:

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED from a CURRENT LOOP P18L TYPE USER S MANUAL

Contents 1. Application... 2 2. Basic requirements, operational safety... 2 3. Installation... 2 3.1. Assembly... 2 3.2. Electrical connections... 3 4. Servicing... 4 5. Accessories... 4 6. Technical data... 5 7. Before a failure will be declared... 5 8. Oredering codes... 6

1. Application The P18L transducer is a device destined for the continuous conversion of relative humidity or ambient temperature into a standard analog current signal. The transducer is fixed on a wall. Applied sensor shields enable the application of the P18L transducer in various ambient conditions 2. Basic requirements, operational safety In the security scope, the transducer meets the requirements of the EN 61010-1 standard. Remarks concerning the operator safety: 1. General All operations concerning transport, installation, and commissioning as well as maintenance must be carried out by qualified, skilled personnel acc. to the section 3.2. of the user s manual. According to this basic safety information, qualified, skilled personnel are persons who are familiar with the installation, assembly, commissioning, and operation of the product and who have qualifications necessary for their occupation. In order to avoid any damage, before switching the supply on, it is recommended to ensure that all wires were correctly connected. Before the transducer assembly, one must pass supplying wires through the packing. Screw the packing seal in order to obtain the leaktightness. If the packing seal is not screwed, we cannot ensure the required IP65 leaktightness. When unpacking the P18L transducer, please check whether the type and version code on the data plate correspond to the order code. 3. Installation 3.1. Assembly The P18L transducer is designed to be mounted on a wall by means of a screw connection or glue without the loss of IP 65 tightness.

The transducer housing is made of a self-extinguishing plastics. Housing dimensions: 64 x 58 x 35 mm. The transducer has screw connectors placed inside the transducer, which enable the connection of external wires of 1 mm 2 cross-section. Overall dimensions and the fixing way are shown on the fig. 1 Fig 1. Overall dimensions of the P18L transducer Mounting holes 6 Fig.2. Lay-out of assembly holes of the P18 transducer

3.2. Electrical connections The P18L transducer has 2 connecting terminals to which there is access after removing the cover of the transducer housing. Fig.3 Marking of terminals for the connection of external signals Fig. 4 Way of transducer electrical connections In case of the transducer work in an environment with high interference, one must apply shielded wires. The shield must be connected to the nearest PE point from the feeder side.

4. Servicing After connecting wires, closing and servicing the housing, and switching to the supply on, the transducer is ready to work. The correct measurement result appears only after the time of the measurement initialisation ca 2.5 minutes. After this laps of time, the analog output is correctly steered on. The transducer converts the temperature or relative humidity into a 4-20 ma standard current signal. The choice of the converted quantity is realized by means of the jumper Nr 1 of the 3-position switch placed on the transducer plate. If the jumper Nr 1 is in the position ON, the transducer converts the relative humidity. (Fig. 5). a) b) Fig. 5 Choice of the converted quantity: a) temperature, b) relative humidity 5. Accessories As a standard, the P18L transducer is equipped with a metallic shield of the sensor, destined only for indoors application. For other applications it is recommended to use additional sensor shields, depending on the transducer operation conditions. 8

Sensor protection shields Table 1 Item Order code Design Name Construction Features Typical application 1 0874-490-016 Membrane filter Casing made of PC, Membrane of teflon laminated by a film. Pore size: 1 mm Mean filtration effect. Maximal temp.: up to 80 C Response time: t10/90: 15 s Building automation. In rooms with low pollution. 2 0874-490-015 Filter made of teflon Sintered teflon. Pore size: 50 mm High chemical resistance.. Maximal temp.: up to 180 C Response time: t10/90: 14 s Drying process in chemical applications 3 0874-490-014 Filter made of sintered bronze Sintered bronze. Pore size: 60 mm High mechanical resistance. To co-operate with high pollution. Applied at small air humidity. Response time: t10/90: 10 s Agricultural applications

6. Technical data Basic parameters: - range of relative humidity measurement (RH) 0...100% without condensation 1) - basic error of relative humidity conversion 1) ± 2% for RH = 10...90% ± 3% for remaining range - hysteresis of the humidity measurement (T) - range of temperature measurement (T) - basic error of temperature conversion ± 1% RH 20...60 C ± 0.5% of the range - additional errors - temperature influence ± 25% of the basic error/10 C Analog output: - current... 20 ma - maximal load resistance of the current output 00 W Rated operating conditions: - supply...30 V d.c. - consumption < 1.5 VA - ambient temperature 30...23...85 C - relative air humidity < 95% (admissible condensation) - rate of air flow m/s 1) In case of water vapour condensation on the sensor surface, the maximal error can increase to 3% RH 10

- pre-heating time minutes - protection degree ensured by the housing IP 65 - fixing on a wall - weight g - dimensions (35 58 118) mm - work position: in applications non-exposed to a direct contact with water in applications exposed to a direct contact with water any with the sensor chamber directed towards the ground. Electromagnetic compatibility: - immunity noise acc. to EN 61000-6-2 - emission noise acc. to EN 61000-6-4 Security requirements: acc. to EN 61010-1 - installation category III - pollution grade - working voltage in relation to the earth 0V 7. Before a failure will be declared Possibilities of incorrect work of the P18L transducer Table 2. Symptoms Data inconsistent with our expectations appear on the transducer output. Procedure In the version with analog outputs, check parameters of the individual characteristic of analog outputs. 11

8. Ordering codes Ordering codes of P18L transducer versions Table 3. Humidity and temperature transducer P18 L - XX X Version: standard... 00 custom-made*...xx Acceptance tests: without additional quality inspection requirements... 0 with an extra quality inspection certificate... 1 other requirements agreed with the customer*... X Example of order: The code: P18L- 0 0-8 means P18L temperature and humidity transducer. 1 current output: 4... 20 ma 00 standard version 8 without additional quality inspection certificate. In case of need, one must order additionally the sensor protection shield acc. to the table 1., e.g. the shield coded: 0874-490-014 means a filter made of sintered bronze. 12

9. Maintenance and warranty The P18L transducer does not require any periodical maintenance. In case of some incorrect operations: 1. In the period of 12 months from the date of purchase: One should take the transducer down from the installation and return it to the Manufacturer Quality Control Dept. If the unit has been used in compliance with the instructions, the Manufacturer warrants to repair it free of charge. 2. After the warranty period: One should turn over the transducer to repair it in a certified service workshop. The disassembling of the housing causes the cancellation of the granted warranty. Spare parts are available for the period of five years from the date of purchase. Our policy is one of continuous improvement and we reserve the right to make changes in design and specifications of any products as engineering advances or necessity requires and revise the above specifications without notice. 13

14

15

SALES PROGRAMME DIGITAL and BARGRAPH PANEL METERS MEASURING TRANSDUCERS ANALOG PANEL METERS (DIN INSTRUMENTS) ANALOG and DIGITAL CLAMP-ON METERS PROCESS and HOUSEHOLD CONTROLLERS CHART AND PAPERLESS RECORDERS POWER CONTROL UNITS and SOLID-STATE RELAYS AUTOMOTIVE DASHBOARD INDICATORS 1-PHASE AND 3-PHASE WATT-HOUR METERS NUMERICAL AND ALPHANUMERICAL LARGE SIZE DISPLAYS ACCESSORIES FOR MEASURING INSTRUMENTS (SHUNTS AND MODULES) MEASURING SYSTEMS (ENERGY, HEAT, CONTROL) CUSTOM-MADE ELECTRONIC SUBASSEMBLIES ACC. TO ORDERS WE ALSO OFFER OUR SERVICES IN THE PRODUCTION OF: ALUMINIUM ALLOY PRESSURE CASTINGS PRECISION ENGINEERING AND THERMOPLASTICS PARTS PRESSURE CASTING DIES AND OTHER TOOLS CUSTOM-MADE ELECTRONIC SUB-ASSEMBLIES MEASUREMENT CONTROL RECORDING QUALITY PROCEDURES: According ISO 9001 and ISO 14001 international requirements. All our instruments have CE mark. For more information, please write to or phone our Export Department. Lubuskie Zak³ady Aparatów Elektrycznych LUMEL S.A. ul. Sulechowska 1 65-022 Zielona Góra - Poland tel.: (48-68) 329 51 00 (exchange) fax: (48-68) 329 51 01 e-mail: lumel@lumel.com.pl http://www.lumel.com.pl 16 Export Department: Tel.: (48-68) 329 53 02 or 53 04 Fax: (48-68) 325 40 91 e-mail: export@lumel.com.pl P18L-07