SMALL DIAMETER Implant

Similar documents
SMALL DIAMETER Implant

NARROW DIAMETER implant

NARROW DIAMETER implant

NARROW DIAMETER implant

GINGIVAL LEVEL implant

ESTHETIC LINE implant

SwishPlant. SwishPlant System Catalog. 4.8mmD mmD. 4.8mmD mmD. 3.7mmD mmD. 6.5mmD

PROSTHETIC COMPONENTS

- RESTORATIVE PRODUCT CATALOG

ESTHETIC LINE implant

The REAL Mini Implant

SwissPlant Prosthetic Catalog. SwissPlant

INTERNAL HEX ( ps) PLATFORM SHIFT PRESERVATION OF BONE NEVER LOOKED BETTER

Legacy Prosthetic Catalog

IQ IMPLANTS Smart Choice PRODUCT C ATA L O G

INTERNAL HEX Implant System

4766 Research Dr. San Antonio, TX insightdentalsystems.com

Park Dental Mini Dental Implants

NEW NEW. An Extended Solution for Narrow Ridges

Legacy TM. System Catalog. Legacy TM 1 Legacy TM 2 Legacy TM 3 Legacy TM 4

ball abutment overdenture: chairside pick-up using existing denture

contents the smarter case approach reasons to choose simplyintegrated 5 system overview 6 ordering 7 mount-free implants 8-9

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

Restoring Straumann implants. with Locator abutments.

NEW. An Extended Solution. for Narrow Ridges

MINI IMPLANT SYSTEM English Instructions for Use MINI IMPLANTS

NEW. An Extended Solution. for Narrow Ridges

3M ESPE MDI. Mini Dental Implants. Quick Order Guide

Blue Sky Bio Multi unit Abutments BIO Multi-Units are available for all our Bone Level Implants

HEXAGON Implant System

Orthodontic Screw System

Where technology meets dentistry INNOVATION. at a GLANCE

PRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable.

Biomimetic PEARL. Product catalogue

Utilizing Digital Treatment Planning and Guided Surgery in Conjunction with Narrow Body Implants. by Timothy F. Kosinski, DDS, MAGD

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

Implant System MAKE IT SIMPLE

OD Secure chairside pick-up using existing denture

Alpha-Bio Tec specializes in the development and production of advanced dental solutions, focusing on the fields of implants and prosthetics. Over the

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l

UDELL DENTAL LABORATORY Instructions for Use PREAT Precision Attachments

simply simply digital simply crown & bridge simply removable simply fixed simply à la carte

Product Catalog. Since 1985» Simple. Predictable. Profitable.

Personal Attention Accurate Dental Solutions. Precision Down to the Smallest Detail. Wide Range of Dental Solutions Engineerd for a Lifetime

Fixed Restoration for Atrophic Ridges

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

Transforming the Implant Industry. Broadest Product Line Highest Quality-Best Value

S i m p l i c I t y, c o m f o r t, a e s t h e t i c s. axiom. The new dimension

Biomimetic PEARL. Product catalogue

N E W S M I L E S E V E R Y D AY

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants

GMI FRONTIER implant system. Surgical procedures guide

InterActive System Catalog

Product Catalog July 2017

Table of Contents. Flexi-Overdenture Characteristics

Locator retained mandibular complete prosthesis (isy Implant System)

CATALOG. Since 1985» Simple. Predictable. Profitable.

TOOTH LOSS AND DENTAL IMPLANT THERAPY: Eating and Smiling with confidence again

Dental Implant Systems. Micro Precision Dental Devices

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER

RDS IMPLANTS PERFECTLY DESIGNED - SIMPLY ASSIGNED

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

Straumann Mini Implant System Basic Information. Technical Information

The Uniti implant system is designed to be simple to learn and use. A seamless surgical protocol renders the system user friendly.

PRODUCT CATALOG / 1 /

Product Catalog August 2018

Osteotome inserts kit, angled. Impression tube (open tray) Selection abutment kit / Selection measurement post. Bar base PMMA & Finisher

DENTAL IMPLANT SYSTEM. Product Catalog. October 2015

A self-tapping internal hex. implant by MAKE IT SIMPLE

Straumann Dental Implant System. Fax Order Form Collection.*

INTRODUCTION. General Information. Important Warning

Trefoil Procedure manual

EN Small. Quick. Easy.

Bone Level. Surgical Guideline. Dental Implant System

Tri-Lobe System Catalog

Clinical Perspectives

Astra Tech Implant System. Manual and product catalog. Guided surgery. Computer guided implant treatment with the Astra Tech Implant System EV

Implant Phase Flow Chart

QZ-Implant TRINON. Bone level implant with hexagonal internal cone connection

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix

Guided surgery manual

SimpleLine II Surgical / Prosthesis Manual

Cost-effective immediate restoration in the anterior region of the mandible (isy by CAMLOG)

Product Catalog January 2017 DENTAL IMPLANT SYSTEM

RATCHETS RATCHET ACCESSORIES DENTAL PRODUCTS PRODUCT CATALOG A company of the KLINGEL GROUP

Dentium Implant System. New Product

A NEW ANGLE IN NARROW DIAMETER IMPLANTS

Instructions for Use DENTAL IMPLANTS

Osteoconductive S.L.A. Surface. Fantastic surface, Bioseal, and Perfect achievement of CMI f ixation.

INNOVATION! The incisive choice

immediate implantation and loading with Paltop Osteotomes for bone expansion Case Study

LOCATOR F-Tx FIXED ATTACHMENT SYSTEM

CAMLOG IMPLANT SYSTEM PRODUCT CATALOG

Smarter Thinking. Simpler Design. Prima Plus. Surgical Manual

PHILOSOPHY SWISS QUALITY PERFORMANCE

prosthetic technique manual

GUIDED SURGERY TECHNIQUE

INDEX. Pag. 12. Pag. 05. Pag. 06. Pag. 13. Pag. 06. Pag. 14. Pag. 15. Pag. 15. Pag. 15. Pag. 15. Pag. 08. Pag. 16. Pag. 09. Pag.

Innovative Präzision Made in Germany

GMI. MONOLITH implant system. Surgical procedures guide

Transcription:

SMA IAMETER Implant

SMA IAMETER Implant Implant characteristics page 04 ental Implants page 06 Prosthetic components page 10 MONOBOCK Implant Implant characteristics page 12 ental Implants page 14 Prosthetic components page 16 S/MB Surgical section Instruments page 18 Surgical kits page 21 Surgical protocol page 24 Site preparation page 26 All of the materials produced by C-TECH follow a validated procedure, which includes surface treatment and packing as well, in conformity with European and international directives EN ISO 13485:2003/AC:207 and 93/42/EEC relative to medical devices. 2

MINI Implant ental precision solutions C-Tech Implant is a dynamic company with aggressive growth, producing components and product lines primarily for dental implantology. International presence With production and management based in Italy, C-Tech Implant is active in all major world markets and is distributed in over 25 countries. Scientific research, advanced technology, simplification C-Tech Implant differentiates itself with attention to research and the application of high technology to its products, all while maintaining a simplicity of insertion and ease of use. C-Tech Implant incorporates the latest trends in implantology but provides very practical surgical and prosthetic solutions aimed at offering the practitioner and the patient optimal results. High quality standards C-Tech Implant products are made to the highest standards governing the manufacturing and management of European medical and dental components. Up to date audits and certifications assure that these standards are vigilantly maintained. Training & advice ental professionals are assisted by the rich knowledge and experience of C-Tech Implant personnel and through C-Tech courses and training sessions. uring these courses the professional is able to learn the latest methods of implant placement and reconstruction. Mission statement The goal of C-Tech Implant is to provide the highest level of quality for technologically advanced products at reasonable prices in order to allow the dental practitioner to find solutions for the broadest range of patients. 3

SMA IAMETER Implant Prosthetic choice Choice between square or o-ball head depending on fixed or removable applications. Micro grooving The lower aspect of the implant collar is endowed with micro grooves to help maintain cortical bone. Collared and non-collared models C-tech provides S models with and without gingival collars, allowing the practitioner to better address cases with differing gingival thicknesses. Fine threading The fine thread S implants are designed to facilitate the placement in hard bone. SEM 1000x Passivated surface The implant surface is blasted with aluminum oxide and then subjected to progressive etching using citric acid. This surface treatment accelerates the osteointegration process by providing a greater and more uniform area of contact between bone and implant while favoring an immediate implant load. Implant body The anatomically shaped implants are produced from medical grade 5 titanium. Smooth collar The top aspect of every collared implant is smooth so as to better accommodate soft tissue. Aggressive threading The aggressive thread for S Implants are designed for the added compression and surface area required in soft bone placement. 4

SMA IAMETER Implant Square Head O-Ball Head Without Collar With collar With Smooth Gingival Collar Micro Grooving Fine Threading Passivated Surface Aggressive Threading 5

ental Implants A S Implant ø1.8 fine thread implants C T C A item# 1.8 16.3 10 CAB-10 17.8 11.5 CAB-115 19.3 13 2.5 3.8 CAB-13 21.3 15 CAB-15 24.3 18 CAB-18 T CAB-10 10 mm CAB-115 11.5 mm CAB-13 13 mm CAB-15 15 mm CAB-18 18 mm S Implant ø1.8 fine thread implants A T A item# 13.9 10 NAB-10 1.8 16.9 13 3.9 NAB-13 18.9 15 NAB-15 T NAB-10 10 mm NAB-13 13 mm NAB-15 15 mm A S Implant ø1.8 fine thread implants T C A item# 16.3 10 SAB-10 1.8 19.3 13 2.5 3.8 SAB-13 21.3 15 SAB-15 C T SAB-10 10 mm SAB-13 13 mm SAB-15 15 mm 6

SMA IAMETER Implant A S Implant ø2.1 fine thread implants C T C A item# 2.1 16.3 10 IAB-10 17.8 11.5 IAB-115 19.3 13 2.5 3.8 IAB-13 21.3 15 IAB-15 24.3 18 IAB-18 T IAB-10 10 mm IAB-115 11.5 mm IAB-13 13 mm IAB-15 15 mm IAB-18 18 mm S Implant ø2.1 fine thread implants A T A item# 13.9 10 NIAB-10 2.1 16.9 13 3.9 NIAB-13 18.9 15 NIAB-15 T NIAB-10 10 mm NIAB-13 13 mm NIAB-15 15 mm A S Implant ø2.1 fine thread implants T C A item# 16.3 10 SIAB-10 2.1 19.3 13 2.5 3.8 SIAB-13 21.3 15 SIAB-15 C T SIAB-10 10 mm SIAB-13 13 mm SIAB-15 15 mm 7

ental Implant A S Implant ø2.5 fine thread implants T C A item# 16.3 10 MC/25/10 2.5 19.3 13 2.5 3.8 MC/25/13 21.3 15 MC/25/15 C T MC/25/10 10 mm MC/25/13 13 mm MC/25/15 15 mm A S Implant ø2.5 fine thread implants T C A item# 16.3 10 MCA/25/10 2.5 19.3 13 2.5 3.8 MCA/25/13 21.3 15 MCA/25/15 C T MCA/25/10 10 mm MCA/25/13 13 mm MCA/25/15 15 mm 8

SMA IAMETER Implant A S Implant ø2.4 aggressive thread implants C T C A item# 2.4 16.3 10 MAB-10 19.3 13 MAB-13 2.5 3.8 21.3 15 MAB-15 24.3 18 MAB-18 T MAB-10 10 mm MAB-13 13 mm MAB-15 15 mm MAB-18 18 mm S Implant ø2.4 aggressive thread implants A T A item# 13.9 10 NMAB-10 2.4 16.9 13 3.9 NMAB-13 18.9 15 NMAB-15 T NMAB-10 10 mm NMAB-13 13 mm NMAB-15 15 mm A S Implant ø2.4 aggressive thread implants T C A item# 16.3 10 SMAB-10 2.4 19.3 13 2.5 3.8 SMAB-13 21.3 15 SMAB-15 C T SMAB-10 10 mm SMAB-13 13 mm SMAB-15 15 mm 9

Prosthetic components Soft retention caps 4.7 3.5 Material: Titanium grade 5 O-Ring Material: FA Buna Available in single packages: MCH-1 Available in packages of 4 caps: MCH-1/4 4.4 MCH-1 soft MC-3005B 5 pieces x5 x10 MC-3005B/10 10 pieces x25 MC-3005B/25 25 pieces Medium retention caps 4.3 3.1 Material: Titanium grade 5 O-Ring Material: FA Buna Available in single packages: MCH-2 Available in packages of 4 caps: MCH-2/4 3.8 MCH-2 medium MC-3005 5 pieces x5 x10 MC-3005/10 10 pieces x25 MC-3005/25 25 pieces Hard retention caps 4 3.1 Material: Titanium grade 5 O-Ring Material: FA Buna Available in single packages: MCH-3 Available in packages of 4 caps: MCH-3/4 3.8 MCH-3 hard MC-3005 5 pieces x5 x10 MC-3005/10 10 pieces x25 MC-3005/25 25 pieces Straight abutment Only for O-ball heads implants 4.3 9.4 Material: Titanium grade 5 MC-3010 O-ball temporary and transfer caps For O-ball and square head implants item# 4.0 7 MC-3013 4.5 6.4 MC-3014 Material: POM MC-3013 Temporary cap MC-3014 Transfer cap 10

SMA IAMETER Implant Castable cap for square head and O-ball 4 6 Material: Plexiglass MC-3006 PVC protection 3.5 4 x5 x10 x25 Material: PVC MC-3008 5 pieces MC-3008/10 10 pieces MC-3008/25 25 pieces Collared analog 2.6 15.8 Material: Titanium grade 5 MC-3007 Non collared analog 2.0 15.8 Material: Titanium grade 5 MC-3012 Collared square head analog 2.6 15.8 Material: Titanium grade 5 MCA-1007 11

MONOBOCK Implant The C-Tech MB, Mono Block Implant, provides 2 different prosthetic options as well as 2 different main body designs to meet the differing requirements of bone and soft tissue encountered in the maxilla and the mandible. Prosthetic Options Choice between square or O-ball head depending on fixed or removable applications. Support for Fixed Recontructions A tapered head with a 4,8mm height above the 3,1mm platform offers and optimal base and structure for the fixed reconstruction. Gingival Collar MAN-OB/MAN-TAP smooth collar provides the platform switching height to accommodate the average mandibular gingival tissue. Mandibular Cortical Maintenance Augmented MAN-OB/MAN-TAP micro grooving for the increased cortical height of the mandibular bone. System Compatiblity Choice of tapered and O-ball head prosthetics. O-ball head is compatible with S, G, B and E O-ball attachments Augmented Gingival Collar MAX-OB/MAX-TAP smooth collar platform switching fits the thicker maxillary gingival tissue Maxilla Type Bone Micro Grooving MAX-OB/MAX-TAP micro grooving accommodates the thinner cortical bone that is encountered in the maxilla. Aggressive Main Body Threading MAX-OB/MAX-TAP main body threading, agressive reverse buttress threads deliver the surface area and stability required by softer maxillary bone Maxilla Type Apex Rounded tip is ideal for the maxilla so as to prevent the possible perforation of the sinus. ow Profile Threading ow profile threading offers surface area yet with the reduced resistance necessary for placement in the 1/2 bone that can be encountered in the mandible. Surface Topography Blasted and acid etched main body surface. Mandibular Apex Sharp apex to facilitate advancement in 1/2 bone. 12

MONOBOCK Implant Prosthetic Options: O-Ball for removable prosthesis Prosthetic Choice: Tapered Abutment for fixed recontructions Gingival Choice: Maxilla Type Gingival Collar Cortical Choice: Maxilla Type Micro Grooving Gingival Choice: Mandibular Type Gingival Collar Cortical Choice: Mandibular Type Micro Grooving Choice Of Main Body Threading: Agressive Threading for Soft Bone Choice Of Main Body Threading: Fine Threading for Hard Bone Rounded Apex Pointy Apex 13

ental Implants MANOB T C A item# 14.3 9 MANOB-09 3 16.3 11 MANOB-11 1.5 3.8 18.3 13 MANOB-13 20.3 15 MANOB-15 A C T MANOB-09 9 mm MANOB-11 11 mm MANOB-13 13 mm MANOB-15 15 mm A MAXOB T C A item# 15.3 9 MAXOB-09 3 17.3 11 MAXOB-11 2.5 3.8 19.3 13 MAXOB-13 21.3 15 MAXOB-15 C T MAXOB-09 9 mm MAXOB-11 11 mm MAXOB-13 13 mm MAXOB-15 15 mm A MANTAP T C A item# 15.3 9 MANTAP-09 3 17.3 11 MANTAP-11 1.5 4.8 19.3 13 MANTAP-13 21.3 15 MANTAP-15 C T MANTAP-09 9 mm MANTAP-11 11 mm MANTAP-13 13 mm MANTAP-15 15 mm 14

MONOBOCK Implant A MAXTAP T C A item# 16.3 9 MAXTAP-09 3 18.3 11 MAXTAP-11 2.5 4.8 20.3 13 MAXTAP-13 22.3 15 MAXTAP-15 C T MAXTAP-09 9 mm MAXTAP-11 11 mm MAXTAP-13 13 mm MAXTAP-15 15 mm 15

Prosthetic components Soft retention caps 4.7 3.5 Material: Titanium grade 5 O-Ring Material: FA Buna Available in single packages: MCH-1 Available in packages of 4 caps: MCH-1/4 4.4 MCH-1 soft MC-3005B 5 pieces x5 x10 MC-3005B/10 10 pieces x25 MC-3005B/25 25 pieces Medium retention caps 4.3 3.1 Material: Titanium grade 5 O-Ring Material: FA Buna Available in single packages: MCH-2 Available in packages of 4 caps: MCH-2/4 3.8 MCH-2 medium MC-3005 5 pieces x5 x10 MC-3005/10 10 pieces x25 MC-3005/25 25 pieces Hard retention caps 4 3.1 Material: Titanium grade 5 O-Ring Material: FA Buna Available in single packages: MCH-3 Available in packages of 4 caps: MCH-3/4 3.8 MCH-3 hard MC-3005 5 pieces x5 x10 MC-3005/10 10 pieces x25 MC-3005/25 25 pieces Straight abutment Only for O-ball heads implants 4.3 9.4 Material: Titanium grade 5 MC-3010 O-ball temporary and transfer caps For O-ball and square head implants item# 4.0 7 MC-3013 4.5 6.4 MC-3014 Material: POM MC-3013 Temporary cap MC-3014 Transfer cap 16

MONOBOCK Implant Castable cap for square head and O-ball 4 6 Material: Plexiglass MC-3006 Tapered head caps Only for tapered head implants item# 4 6.9 MB-3013 2.1 6.5 Material: MB-3013 - PEEK MB-3014 - PEEK MB-3006 - CPMMA MB-3014 MB-3006 MB-3013 Tapered impression cap MB-3014 Tapered temp cap MB-3006 Tapered waxing coping PVC protection 3.5 4 x5 x10 x25 Material: PVC MC-3008 5 pieces MC-3008/10 10 pieces MC-3008/25 25 pieces Collared O-ball analog 2.6 15.8 Material: Titanium grade 5 MC-3007 Tapered analog 3.1 17.85 Material: Titanium grade 5 MB-ANAOG 17

Instruments 1 S rills 2 1 2 item# 1.1 MC-3001/11 14.3 1.3 MC-3001/13 33.3 1.5 MC-3001 17.5 2.0 MC-3001/20 Material: Stainless steel MC-3001/11 single use MC-3001/13 MC-3001 MC-3001/20 SB/MB Butterfly driver 8.5 7 Material: Stainless steel MC-3002 S/MB Adapters item# 4 MC-3003S 8 MC-3003M 12 MC-3003 MC-3003S Short MC-3003M Medium MC-3003 ong Material: Stainless steel S/MB atch implant driver 3.2 22 Material: Stainless steel MC-3020 S/MB Finger adapter 12 8.6 Material: Stainless steel CT-E7002 for ratchet drivers 18

MINI Implant 1 1 S/MB Marking and pilot drills 2 2 1 2 item# 29 15 2.1 CT-2020 35.2 17.2 2.3 CT-1720E Material: Stainless steel CT-2020 CT-1720E 1 Counterbore 3 2 1 2 2 3 3 23.9 4.8 3.1 4.5 3.5 Material: Stainless steel 2 3 E-3138 1 MB Main drill 2 1 2 36.7 17.2 2.6 Material: Stainless steel N-1726E MB rill Extender 25 Material: Stainless steel CT-2000 MB Tissue punch 3 2.8 Material: Stainless steel TCP-3MM 19

Instrumentation S/MB Torque wrench up to 50Ncm CT-8010 Torque Wrench PEEK Material: Stainless steel and PEEK CT-8010PEEK S/MB Ratchet without torque MC-00376 S/MB Hand driver Material: Stainless steel E-3016 S/MB O-ring tool Material: Stainless steel MC-3018 20

MINI Implant S/MB Kit SURKIT05 Torque wrench CT-8010 Adapters MC-3003M - MC-3003 Butterfly driver MC-3002 Tissue punch TCP-3MM ocator drill CT-2020 rill extender CT-2000 Initial drill CT-1720E rills MC-3001/11 - MC-3001/13 MC-3001 Main drill N-1726E Counterbore E-3138 21

S Kit MC-00075SC Torque wrench CT-8010 Butterfly driver MC-3002 rills* MC-3001/11 - MC-3001/13 MC-3001 - MC-3001/20 Adapters MC-3003S MC-3003 * Each surgical kit is equipped with 2 drills; customers can chose drills between ø 1.1, 1.3, 1.5, 2.0. Customers should communicate the choice of the drills at the moment of the order. 22

MINI Implant N/MB Kit SURKIT06 Torque wrench CT-8010 N implant ratchet N-E7001 N-E7001 Adapters MC-3003M - MC-3003 Butterfly driver MC-3002 Prosthetic ratchet CT-8051 Hex driver CT-9025S Tissue punch TCP-3MM ocator drill CT-2020 rill extender CT-2000 Initial drill CT-1720E epth stops CT-STOP07 - CT-STOP08 CT-STOP09 Main drill N-1726E Counterbore E-3138 23

Surgical Protocol Case planning Following evaluation of the patient and the corresponding panoramic radiographs, the type and number of implants and planned placement sites are established. There should be a minimum of 4 implants for mandibular cases and a minimum of 6 for maxilla cases. The implant planning transparency is used to establish the implant length. A minimum of 5mm between each implant needs to be maintained to allow space for the housings. In mandibular cases the implants should be placed starting with a minimum of 5mm anterior of the mental foramen. Following implant site planning the sites are transferred to the gingiva and marked with sterile marker or bleeding points. 1 Pilot site drilling and initial insertion The drill is placed over the sites and lightly pumped up and down till the cortical plate is perforated. The drill should provide sterile irrigation. Unless the crestal bone is sharp or defective there will be no need to raise flap or incision. In the case of average hardness of the bone, then the drill depth should be approximately 1/3 the length of the implant. In the case of hard bone then the depth should be extended to ¾ of the length of the implant. The implant is removed from the sterile vial and the tip of the implant is placed into the drilled site, using the implant mount cap as initial driver. The implant is driven into the bone exerting downward pressure and clockwise motions. Once the bone has been engaged the resistance will become too great to proceed further, it is now time to disengage the cap from the implant and proceed to the next instrument. 2 Continuing the insertion with the butterfly driver 3 Following the initial insertion one will use the butterfly driver, which allows for applying more torque. It should be possible to seat the implant completely with this instrument but should the implant not be completely seated and further advancement is not possible due to resistance, one will then require the ratchet or torque ratchet for final seating. Final implant seating Final seating is accomplished through use of the torque ratchet. The torque ratchet should be set to 35 Ncm. The ratchet adapter is inserted into the opening at the end of the ratchet with the female aspect of the adapter protruding. The adapter is then fitted over the top of the implant, engaging the square part beneath the O-ball. A finger should be placed over the end of the ratchet in order to stabilize the insertion and prevent lever action on the end of the implant. The ratchet is moved in quarter turn increments, pausing in between each turn, thus allowing the bone to expand. The implant is considered primarily stable once 35 Ncm has been achieved. The implant is completely seated once the O-ball and the square part beneath are the only parts protruding from the gingiva. If primary stability has been achieved prior to achieving final seating, then the torque setting should be raised to 50 Ncm, the point at which a fracture can occur. Should the resistance be too much to achieve final seating, then the implant should be slowly backed out and the pilot drill should be used to deepen the osteotome site. 4 5 6 24

MINI Implant Prosthetic Protocol Following proper prosthetic protocol is essential to case success The base of the denture is relieved in order to freely accommodate the heads of the implants and the housings seated on the o-balls. The denture should be relieved until the housings no longer come into contact with the ceiling of the denture base. The denture should be cleaned thoroughly of all acrylic powder residue. Take the PVC tubing and, using a scalpel or scissors, cut off 1.5mm lengths corresponding to the quantity of set implants. Slip the cut lengths of tubing around the necks of the implant heads and into the gingiva but below the implant O-ball. Fit the housings over all O-ball heads, the tubing should not obstruct the full seating of the housings over the O-balls. Using cold curing acrylic, apply small amounts to the tops of the housings and fill the hollowed trough of the denture base with the acrylic. Set the denture over the housings in the patient s mouth. Have the patient bite down on the denture in a normal occlusion with normal pressure. The acrylic will require approx 8 minutes to set, after which the denture is removed and excess acrylic is trimmed and polished away. 1 2 3 4 5 25

Site preparation Ø1.8 - Ø 2.1 CAB/NAB/SAB/IAB/NIAB/SIAB 2,5 mm 3,8 mm 2,5 mm 3,8 mm 1000-1500 rpm 100-750 rpm 1/3 ength of implant Insertion Torque: 35-45 ncm Insertion Torque: 35-45 ncm. 10 mm. 11,5 mm. 13 mm. 15 mm. 10 mm. 11,5 mm. 13 mm. 15 mm 2 mm ø1.8 ø2.1 CT-2020 ocator rill MC-3001/11 ø 1.1 mm rill MC-3002 Butterfly river MC-3003S MC-3003M MC-3003 Ratchet Adapter Ø2.5 - Ø 2.4 MC-25/MCA-25/MAB/NMAB/SMAB 2,5 mm 3,8 mm 2,5 mm 3,8 mm 1000-1500 rpm 100-750 rpm 1/3 ength of implant Insertion Torque: 35-45 ncm Insertion Torque: 35-45 ncm. 10 mm. 13 mm. 15 mm. 10 mm. 13 mm. 15 mm 2 mm ø2.5 ø2.4 CT-2020 ocator rill MC-3001/11 ø 1.1 mm rill MC-3002 Butterfly river MC-3003S MC-3003M MC-3003 Ratchet Adapter 26

SMA IAMETER Implant 1 AITIONA STEPS 100-750 rpm Full ength of implant Insertion Torque: 35-45 ncm Insertion Torque: 35-45 ncm MC-3001 ø 1.5 mm rill MC-3002 Butterfly river MC-3003S MC-3003M MC-3003 Ratchet Adapter 1/2 AITIONA STEPS 100-750 rpm Full ength of implant Insertion Torque: 35-45 ncm Insertion Torque: 35-45 ncm MC-3001 ø 1.5 mm rill MC-3002 Butterfly river MC-3003S MC-3003M MC-3003 Ratchet Adapter 27

Site preparation MAN - TAPER / MAN - O-BA FOR ENSITY 1/2 2.3mm 1.5mm 4.8mm ø3.2 ø3.0 1.5mm 3.8mm ø3.0 ø3.0 800-1000 rpm 100-750 rpm Full ength of implant 100-750 rpm 2/3 ength of implant Insertion Torque: 35-45 ncm 9mm 11mm 13mm 15mm 9mm 11mm 13mm 15mm 4 mm ø3.0 ø3.0 TCP - 3mm 3mm Tissue Punch CT-2020 ocator rill CT-1720E Initial drill N-1726E ø 2.6 mm drill MC-3003S MC-3003M MC-3003 Ratchet Adapter MAX - TAPER / MAX - O-BA FOR ENSITY 2/3 2.3mm 2.5mm 4.8mm ø3.2 ø3.0 2.5mm 3.8mm ø3.0 ø3.0 800-1000 rpm 100-750 rpm Full ength of implant Insertion Torque: 35-45 ncm 9mm 11mm 13mm 15mm 9mm 11mm 13mm 15mm 4 mm ø3.0 ø3.0 TCP - 3mm 3mm Tissue Punch CT-2020 ocator rill CT-1720E Initial drill MC-3003S MC-3003M MC-3003 Ratchet Adapter 28

MONOBOCK Implant Explanation of rill Marking 1/2 Additional steps 100-750 rpm Full ength of implant 100-500 rpm Insertion Torque: 35-45 ncm The drill markings do not include the point of the drill. The point of the drill is 0.4 mm long, thus the drill marking of 7 mm is actually 7.4 mm from the very tip to the bottom of the first black line. The implant should be set approximately 1 mm sub crestally, thus for a 13 mm implant, one should drill to the 14 mm. The use of metal stop is recommended. 15.5 mm 15 mm N-1726E ø 2.6 mm drill E-3138 ø 3 mm Counterbore MC-3003S MC-3003M MC-3003 Ratchet Adapter 13.5 mm 13 mm 11.5 mm 11 mm 1/2 Additional steps 9 mm 9.5 mm 7.5 mm 7 mm 100-750 rpm Full ength of implant Insertion Torque: 35-45 ncm N-1726E ø 2.6 mm drill MC-3003S MC-3003M MC-3003 Ratchet Adapter 0 mm -0.4 mm 29

30

MINI Implant 31

English version REV.02/11-2018 Via Cesare Battisti n. 2-40123, Bologna - ITAY Tel. +39 051 6661817 - Fax +39 051 6667071 www.c-tech-implant.com - info@c-tech-implant.com Go to www.c-tech-implant.com Follow us on facebook and on Instagram