Assembling of fluid filtration system for quantitative evaluation of microleakage in dental materials

Similar documents
The effect of calcium hydroxide on the sealing properties of MTA apical barrier

Long Term Evaluation of the Sealing Ability of 2 Root Canal Sealers in Combination with Self-etching Bonding Agents

Comparison of apical and coronal sealing in canals having tapered cones prepared with a rotary NiTi system and stainless steel instruments

SCIENTIFIC ARTICLES. ltzhak Abramovitz, DMD, Michael Tagger, DMD, MS, Aviad Tamse, DMD, and Zvi Metzger, DMD

Long-term sealing ability of Pulp Canal Sealer, AH-Plus, GuttaFlow and Epiphany

Effect of the smear layer on apical seals produced by two calcium silicate-based endodontic sealers

A new technique for preprosthetic restorations.

A comparative analysis of microleakage of three root end filling materials an in vitro study

ENDODONTOLOGY. Evaluation of the effect of chlorhexidine gluconate as an endodontic irrigant on the apical seal - An in vitro study INTRODUCTION

INTERNATIONAL JOURNAL OF CURRENT RESEARCH IN CHEMISTRY AND PHARMACEUTICAL SCIENCES

Comparison of Coronal Microleakage of Canals Filled with Gutta Percha and Resilon with a Glass Ionomer Coronal Barrier

Coronal and apical leakage analysis of two different root canal obturation systems

The Graduate School Yonsei University Department of Dentistry Myoungah Seo

Effect of Nd:YAG laser irradiation on adherence of retrograde filling materials: evaluation by micro-computed tomography

Effect of resin-coating technique on coronal leakage inhibition in endodontically treated teeth

Curriculum Vita. JAMAL AQRABAWI Associate professor, Endodontics Faculty of Dental Medicine University of Jordan

Med. J. Cairo Univ., Vol. 84, No. 2, March: , 2016

Leakage along warm gutta-percha fillings in the apical canals of curved roots

The Effect of Chlorhexidine Gluconate as an Endodontic Irrigant on the Apical Seal: Long-term Results

Dental materials and cements, and its use in children

UvA-DARE (Digital Academic Repository) New insights into the root canal wall Shemesh, H. Link to publication

Comparison of removal of endodontic smear layer using NaOCl, EDTA, and different concentrations of maleic acid A SEM study

Methodologies for assessment of apical and coronal leakage of endodontic filling materials: a critical review

Virtuosity is in your hands. Endodontic and Microsurgical Ultrasonic Instruments

A COMPARATIVE STUDY OF ROOT CANAL FILLINGS BASED ON WARM GUTTA-PERCHA CONDENSATION TECHNIQUES

ENDODONTOLOGY. Introduction. Original Research ABSTRACT

Comparison of Bacterial and Dye Microleakage of Different Root-End Filling Materials

Microleakage of different types of temporary restorative materials used in endodontics

ENDODONTOLOGY. An in-vitro evaluation of apical sealing of three epoxy resin based commercial preparations INTRODUCTION MATERIALS AND METHODS ABSTRACT

Evaluating the Sealing Ability of MTA as a Root Canal Sealing Material

MICROLEAKAGE ALONG GLASSIX GLASS FIBRE POSTS CEMENTED WITH THREE DIFFERENT MATERIALS ASSESSED USING A FLUID TRANSPORT SYSTEM

In vitro evaluation of root canal preparation with plastic endodontic rotary finishing file - A SEM study

Dye Leakage of Four Root End Filling Materials: Effects of Blood Contamination

Dowel restorations Treatment with a post and core

J. Int Oral Health 2011 Case Report All right reserved

Objectives: To investigate the bond strength and seal ability produced by AH Plus/guttapercha,

Push-out of root canal filling using the material testing stage (MTS) inside a Micro-CT: preliminary observations

Comparison of White MTA And Grey MTA in the Apical Sealing Ability of Lased And Unlased Root Canal Walls - A Pilot Study

Endodontics. Lec.7 د. حسن الرماحي 5 th class. Obturation techniques

Microleakage of Root Canal Sealed with Temporary Endodontic Sealing Materials

how to technique How to treat a cracked, but still inact, cusp. Disadvantages. 1 Issue Full coverage crown. >>

Sealing Ability of Mineral Trioxide Aggregate and Calcium- Enriched Mixture Cement as Apical Barriers with Different Obturation Techniques

Pelagia Research Library. Comparison of microleakage in bonded amalgam restrorations using different adhesive materials: An invitro study

Evaluation of Apical Sealing Ability of Three Different Root Canal Sealers.

Goldberg, Robert A. DDS; Kuttler, Sergio DDS; Dorn, Samuel O. DDS. Publisher:(C)2004The American Association of Endodontists

Intraorifice sealing ability of different materials in endodontically treated teeth

University Lille Nord de France, Lille, France 3) Department of Endodontics, Faculty of Dentistry, University Lille Nord de France, Lille, France

Smear layer removal evaluation of different protocol of Bio Race file and XPendo Finisher file in corporation with EDTA 17% and NaOCl

WaveOne Gold reciprocating instruments: clinical application in the private practice: Part 2

Effects of Simulated Lateral Canals on the Accuracy of Measurements by an Electronic Apex Locator

The Effect of Irrigation with Doxycycline or Citric Acid on Leakage and Osseous Wound Healing

Root canal therapy. Phase 1: Relief of pain

MTA MIRACLE IN DENTISTRY Shikha Singh*,Rahul Maria**,AU Palekar***,Sweta Singh*.

SCIENTIFIC INFORMATION. On the Gold Standard in Root Canal Sealer Materials SEALED. EFFECTIVE. PROVEN.

In vitro evaluation of root canals obturated with four different techniques. Part 3: Obturation of lateral canals

Effect of intra - orifice barriers on the fracture resistance of endodontically treated teeth An Ex-Vivo study

Leakage evaluation of three different root canal obturation techniques using electrochemical evaluation and dye penetration evaluation methods

Apical Dentin Permeability and Microleakage Associated with Root End Resection and Retrograde Filling

KING SAUD UNIVERSITY College of Dentistry. Department of Restorative Dental Sciences DIVISION OF ENDODONTICS COURSE OUTLINE 323 RDS

ORIGINAL ARTICLE INTRODUCTION

Outcome of Root Canal Treatment Using Soft-Core and Cold Lateral Compaction Filling Techniques: A Randomized Clinical Trial

Push-out bond strength of different endodontic obturation material at three different sites - In-vitro study

RESTORING ENDODONTICALLY TREATED TEETH POST RESTORATIONS CROWNS. Dr. Szabó Enikő associate professor

Root end preparation techniques Summary of papers

Case Note Retrieval of a separated file using Masserann technique: A case report

Thermoplastic Obturation Systems. Our innovation Your success

Limited To Endodontics Newsletter. Limited To Endodontics A Practice Of Endodontic Specialists July Volume 2

502 Jefferson Highway N. Champlin, MN Saving Your Teeth with ROOT CANAL THERAPY

Comparison of the effect of Er, Cr-YSGG laser and ultrasonic retrograde root-end cavity preparation on the integrity of root apices

CORESTA RECOMMENDED METHOD N 22

Coronal microleakage with five different temporary restorative materials following walking bleach technique: An ex vivo study

Innovative revolutionary approach to root canal preparation

SCANNING ELECTRON MICROSCOPE EVALUATION OF THE CUT ROOT SURFACE AND ROOT END PREPARATION USING VARIOUS TECHNIQUES

Corresponding Author:Dr.Sneha Vaidya 3

The App to seal! Endo-Resto System. Sealed Safe Certified. For Immediate Post-Endodontic Restorative Treatment. For better dentistry

In vitro experiment on the sealing ability by high-temperature thermoplasticized

RESTORATIONS IN ENDODONTIC. Epita S. Pane Cons Dept FKG USU

In vitro evaluation of root canals obturated with four different techniques Part 2: Apical leakage

Vikram M, 1 * Shetty N, 2 Singh VP 3. Nepal Journal of Medical Sciences Original Article

Physical and Chemical Properties of a New Mineral Trioxide Aggregate Material

Title. Citation 北海道歯学雑誌, 38(Special issue): Issue Date Doc URL. Type. File Information

An In Vivo Evaluation of Two Types of Files used to Accurately Determine the Diameter of the Apical Constriction of a Root Canal: An In Vivo Study

In vitro evaluation of the sealing ability of three newly developed root canal sealers: A bacterial microleakage study

Microleakage around zirconia crowns after ultrasonic scaling around their margin

AN IN VITRO ASSESSMENT OF CORONAL MICROLEAKAGE IN ROOT-FILLED Endodontics TEETH

How to whiten a non-vital anterior tooth. 2,3. At home, the patient injects 10% carbamide peroxide into the access cavity.

Comparison of Spreader Penetration during Lateral Compaction of 0.04 and 0.02 Tapered Gutta-Percha Master Cones

Dental Research Journal

The first and only dentine in a capsule

Final Thesis Defense Examination. Anthony L. Horalek, DDS June 12, 2002

Journal of Endodontics

ORIGINAL RESEARCH. Velayutham Gopikrishna, MDS and Anantanarayanan Parameswaren, MDS. Abstract. Introduction

Evaluation of apical and lateral extrusion of sealer using different sized thermoplastized obturators.

MTA UNIVERSAL - DirectCaps- Mineral Trioxide Aggregate

Evaluation of Gutta-Percha-Filled Areas in Root Canals after Filling by Two Different Obturation Techniques

Instructions For Use

SEALING ABILITY AND MICROSCOPIC ASPECTS

Coronal leakage following three obturation techniques

stabilisation and surface protection

CLINICAL AND RADIOGRAPHIC EVALUATION OF DIRECT PULP CAPPING PROCEDURES PERFORMED BY POSTGRADUATE STUDENTS

Transcription:

ORIGINAL ARTICLE Assembling of fluid filtration system for quantitative evaluation of microleakage in dental materials Maryam Javidi 1 DDS, MS, Neda Naghavi 2 * DDS, MS, and Ehsan Roohani 3 DDS 1. Associate Professor of Endodontics, Dental School/Dental Research Center, Mashad University of Medical Sciences, Mashad, Iran. 2. Assistant Professor of Endodontics, Dental School, Mashad University of Medical Sciences, Mashad, Iran. 3. Postgraduate student of Restorative Dentistry, Dental School, Mashad University of Medical Sciences, Mashad, Iran. Abstract Introduction: There are several methods for evaluating microleakage in dentistry, for example dye or bacterial leakage, electro-chemical methods, radioisotope labeling and fluid filtration. The purpose of this study was to assemble the fluid filtration system for quantitative evaluation of microleakage in dental materials. Materials and Methods: The roots were connected to a tube filled with an underwater pressure supply. A bubble was introduced into the water to measure endodontic leakage. A digital camera and professional software were utilized to record and measure the bubble displacement. Results: Our system was constructed successfully and functioned correctly. Conclusion: In this pilot study we found this system efficient for the evaluation of microleakage of dental materials.(iranian Endodontic Journal 2008;3:68-72) Keywords: Bacterial leakage, Dye leakage, Fluid filtration, New device Received February 2008; accepted June 2008 *Correspondence: Dr. Neda Naghavi, Department of Endodontics, Dental School, Mashad University of Medical Sciences, Mashad, Iran. E-mail: naghavin@mums.ac.ir Introduction The fluid filtration method, introduced and developed by Pashley et al. has been extensively used for 20 years for understanding the physiology of dentin (1), as well as the affects of various restorative treatments on dentin permeability (2). Microleakage, whether apical or coronal, is still a clinical problem and a possible cause of failure in endodontic treatments. Leakage studies have become very popular in dental research and many methods and devices have been introduced for microleakage evaluation. The introduction of the fluid filtration method in endodontics (3), has gained popularity in evaluating apical or coronal microleakage. Many researchers have evaluated the sealing efficiency of root end filling materials (4-8), apical leakage of post and core restorations in endodontically treated teeth (9) and the microleakage of temporary restorative materials (10). This method has also been used to compare the sealing efficiency of different root canal filling methods (11-13). This method presents several advantages over the common dye penetration method: the samples are not destroyed, permitting the evaluation of sealing efficiency over time; the results are automatically records avoiding any operator bias; the results are very accurate because very small volumes can be recorded (14) and no tracer is needed with the related problems of molecular size, affinity for dentin, or ph as major problems in the dye penetration method. No intricate materials are required as in bacterial penetration studies or radioactive tracer studies (15). However, there is no standardization of the materials and methods. The pressure used ranged from 10 to 20 psi, 0.1 to 5 atm or 15 to 30 cm H2O, and the measurement time ranges from 1 min to 3 h (16). The result is generally expressed as µl/min/cm H2O. The purpose of this study was to assemble the fluid filtration system for quantitative evaluation of microleakage in dental materials. 68

Fluid filtration system Figure 1. A schematic view of new designed system Materials and Methods This system involves the evaluation of fluid transport in specimens calculated from bubble movement. It is necessary to apply pressure to fluid to move through the specimen and displace the bubbles. Therefore an oxygen tank equipped with a manometer (to precise adjustment of pressure) was utilized. A specific plastic tube was connected to the oxygen source and the end part was connected to an Erlen. Two holes were made on the Erlen's cap, one for the entrance of oxygen and the other for emersion of fluid (Figure 1). The oxygen tube was fixed above the fluid in the Erlen, but the glass cylinder was entirely immersed in water (the end that removes the fluid) and the other side of this cylinder was connected to a micropipette (0.1 cc) by a plastic tube. This micropipette was fixed on a vertical plate and its other end was connected to a three-valve tube by a latex pipe (0.5 cm in diameter and approximately 2 cm in length). The three-valve tube was equipped with a bilateral control faucet; when turned on, only two directions were connected. The upper side of the three-valve tube was connected to a syringe, which was used to create an air bubble through the micropipette. The diameter of the air bubble should not be smaller than the internal diameter of the micropipette so its movement will be a precise indicator for fluid movement in the micropipette. The lower side was used to connect specimens (discussed below). All of the connections of this system were smeared with cyanoacrylate glue (Inter Lock Co., Japan) and covered by multiple layers of Parafilm strips (Parafilm M, Laboratory Film, Chicago, USA). This strip seals connections in experimental tubes to guarantee an impervious connection. Micropipette, connections and the three-valve tube were fixed on the vertical plate of the system made of compressed plastic. This vertical plate was mounted on a completely stable horizontal MDF plate (22 34 cm in diameters). The role of this horizontal plate was to provide stability for the vertical plate and to communicate between two parts of the system; the two parts are as outlined below (Figure 1). Part 1 consists of tubes, micropipette, pipes and a tooth sample that transfer pressure to the specimen and Part 2 contains a recorder of fluid transport. For the first time we used a digital camera (Olympus, C765, 4 MP, Japan) and a professional software (AutoCAD 2006, Autodesk, Inc.) in this system to record and measure the amount of bubble displacement. We mounted the camera on the horizontal plate using a small tripod with a distance of 32 cm from the vertical plate. It was placed on the middle of the micropipette to prevent minimal errors. Its distance from the micropipette was the closest possible to allow the camera to cover the entire range of the bubble's movement. The outer surfaces of all teeth except the apical 2 mm should be covered with Parafilm strips. We considered two negative control samples to ensure that there was no leakage or fluid movement within the device. These teeth samples were intact with the outer side of the root, crown and the apical foramen entirely covered by multiple layers of Parafilm strips. In the positive control samples the root was not covered (the canals were instrumented but not obturated), this is to ensure that all system paths were opened without obstruction. The apical end of the root excluding apical foramen was covered by cyanoacrylate glue and inserted in a latex pipe (Guihua Co., China) with a 0.5 cm internal diameter and 5 cm length. The free end of the pipe was connected to the only free end of the three-valve tube (the lower end). This junction was sealed completely by Parafilm strip. The control faucet was closed toward the 69

Javidi et al. tooth, so only the syringe and the micropipette was connected. We used the syringe to insert an appropriate air bubble to the micropipette. Once this was carried out the sample was ready for experiment. Its relevant number was written near the micropipette. The camera was adjusted in the macrograph to take precise picture in a short distance. The control faucet was opened to the tooth and the syringe was removed from the pass. Now only the tooth and the fluid filtration system were connected. Then the major faucet of the oxygen tank was opened. The pressure was previously adjusted, since it should be constant during all steps of the experiments. The first picture of the bubble position in the micropipette was taken after 30 sec to reach a balance in the system. Four subsequent pictures were taken at 2-minute intervals (2, 4, 6 and 8 min after the first one). At the end of the experiments, the faucet for the oxygen tank and then the control faucet to the samples were closed. The Parafilm strips were opened and the latex pipe was disconnected from the three-valve tube. The same steps were repeated for the next samples. Five pictures of each sample were transferred to the computer. The bubble position in each picture was determined by professional software (Auto CAD 2006). The precision of this software was 0.1 mm, so with the device used in this study, the smallest recordable displacement was 0.031 mm and the smallest recordable volume was about 10-8 liter. Displacement measures were introduced to custom-made software designed for accelerating the calculations. This software calculates the mean displacement of the bubble per minute and then with a specific quotient converts the longitudinal displacement of the bubble into the volume of fluid passing from the samples showing it as µl/min/cm H2O unit. Thus one number for each sample represented the amount of leakage in the canal (µl/min/cm H2O). Results There was no bubble displacement in the negative control samples, but in the positive control samples as soon as the major faucet of the oxygen tank was opened fluid flow was observed.in this pilot study the method utilized was efficient for the evaluation of microleakage in dental materials. Discussion The purpose of this study was to assemble a novel fluid filtration system. There is an absence of a standard fluid filtration system. Wimonchit et al. used a pressure of 100 mmhg for evaluation of different methods for leakage assessment (15), Pommel et al. used a pressure of 15 cm H2O (17), Bobotis et al. used a pressure of 20 psi for the evaluation of leakage of temporary filling materials (18), and in the study of Abramovitz, the applied pressure was 1.2 atm (19). Researchers have used different methods to produce the needed pressure for their study. We used O2 pressure because it remains unchanged during the experiment and is adjustable for different clinical situations. Also we used a digital camera for recording the bubble displacement because of its extreme precision and as it permits the rereading the fluid displacement. It is also time saving. This method is based on forcing liquid through the sealer or its existing voids, dentin walls and gutta-percha. Therefore the results may follow the laws governing the phenomena of filtration, such as the Poiseuille-Hagen equation, and may be modified by factors like applied pressure or measurement time (1). The compliance of the system and the initial filling of microscopic voids may explain the decrease in fluid flow over time. Compliance is the change in volume of a system for every unit change in pressure. For instance a large bubble may compress more than a small one, and long elastic tubing may expand more than small rigid ones. These changes would be exaggerated at high pressures. The compliance of the system may be of concern for a small measurement of time but not if one waits for enough time for the fluid under pressure in the system to reach a steady state with regards to bubble compression and tubing expansion (1). Several parameters modify the outcome of the work: the diameter of tube containing the bubble, time and applied pressure. In fact, the time factor 70

Fluid filtration system was not chosen for its clinical relevance but rather for the convenience of the researcher. This does not pose a problem as the purpose of this study was to draw comparisons between different techniques or different materials; not to correlate the results to a clinical situation. Thus the amount of time should be as long as possible to increase the accuracy of the measurement without leading to exaggerated and useless results. We conducted this pilot study to: 1- have confidence in non-leaking connections; 2- make calibration of the system and allow primary adjustment such as oxygen pressure; 3- evaluate the efficacy of camera used for recording the result; 4- evaluate the ability of software in reading the results; 5- predict probable problems that may occur. As mentioned before, our software calculates the mean displacement of a bubble per minute and then using a specific quotient converts the longitudinal displacement of the bubble into the volume of fluid current from the samples and shows it as µl/min/cm H2O. This quotient is the sum of the quotients outlined below. 1- Camera's magnification ratio: a digital camera with a resolution of 5 megapixels has a constant magnification when photos are taken in an invariable distance. We calculated this magnification and used it as a quotient. 2- Length to volume conversion ratio: 1 mm displacement of bubble in the pipette is equivalent to a constant volume of fluid movement in the sample. This ratio was applied as a quotient too. 3- The atmosphere to cm H2O conversion ratio: we decided to represent the results as µl/min/ cm H2O to accelerate comparing them with results of other studies. It is noteworthy that we can change the applied pressure, the time of experiment or the number of intervals according to the protocol of this study; the only changes being the data entered into the software. Since the recorded volume is divided by the measurement time and the pressure to express the results (ie, µl/min/the unit of pressure), there is a linear relationship between the volume, time measured and pressure. Conclusion This system was assembled successfully for quantitative evaluation of microleakage in dental materials, with the precision of 10-1 Lit for the smallest recordable volume and as a result, we had one number for each sample that represented the amount of leakage as µl/min/cm H2O. Acknowledgement This study was supported by a grant (87227) from Mashad University of Medical Sciences, Mashad, Iran. References 1. Pommel L, Camps J. Effects of pressure and mewe had one number for eachasurement time on the fluid filtration method in endodontics. J Endod 2001;27: 256-8. 2. Camps J, Saradell JM, Dejou J, Pignoly C, Jacquot B. influence of concentration and application time of maleic acid on dentine permeability. Dent Mater 1995;11: 177-81. 3. Yoshimura M, Marshall FJ, Tinkle JS. In vitro quantification of the apical sealing ability of retrograde amalgam fillings. J Endod 1990;16:5-12. 4. Wu MK, Kontakiotis EG, Wesselink PR. Long-term seal provided by some root-end filling materials. J Endod 1998;24:557-60. 5. Yatsushiro JD, Baumgartner JC, Tinkle JS. Longitudinal study of the microleakage of two rootend filling materials using a fluid conductive system. J Endod 1998;24:716-9. 6. Forte SG, Hauser MJ, Hahn C, Hartwell GR. Microleakage of super-eba with and without finishing as determined by the fluid filtration method. J Endod 1998;24:799-801. 7. Tay KC, Loushine BA, Oxford C, Kapur R, Primus CM, Gutmann JL, Loushine RJ, Pashley DH, Tay FR. In vitro evaluation of a Ceramicrete-based root-end filling material. J Endod 2007;33:1438-43. 8. Pelliccioni GA, Vellani CP, Gatto MR, Gandolfi MG, Marchetti C, Prati C. Proroot mineral trioxide aggregate cement used as a retrograde filling without addition of water: an in vitro evaluation of its microleakage. J Endod 2007;33:1082-5. 9. Bachicha WS, DiFiore PM, Miller DA, Lautenschlager EP, Pashley DH. Microleakage of endodontically treated teeth restored with posts. J Endod 1998;24:703-8. 10. Waite RM, Carnes DL Jr, Walker WA 3rd. Microleakage of TERM used with sodium perborate/ 71

Javidi et al. water and sodium perborate/superoxol in the "walking bleach" technique. J Endod 1998;24:648-50. 11. Wu MK, De Gee AJ, Wesselink PR. Leakage of four root canal sealers at different thickness. Int Endod J 1994;27:304-8. 12. Nagas E, Uyanik MO, Sahin C, Durmaz V, Cehreli ZC. Effects of different light-curing units and obturation techniques on the seal of the Resilon/ Epiphany system. J Endod 2008;34:1230-2. 13. Sagsen B, Er O, Kahraman Y, Orucoglu H. Evaluation of microleakage of roots filled with different techniques with a computerized fluid filtration technique. J Endod 2006;32:1168-70. 14. Wu MK, Wesselink PR. Endodontic leakage studies reconsidered. Part I. Methodology, application and relevance. Int Endod J 1993;26:37-43. 15. Wimonchit S, Timpawat S, Vongsavan N. A comparison of techniques for assessment of coronal dye leakage. J Endod 2002;28:1-4. 16. Wu MK, De Gee AJ, Wesselink PR, Moorer WR. Fluid transport and bacterial penetration along root canal fillings. Int Endod J 1993;26:203-8. 17. Pommel L, Jacquot B, Camps J. Lack of correlation among three methods for evaluation of apical leakage. J Endod 2001;27:347-50. 18. Bobotis HG, Anderson RW, Pashley DH, Pantera EA Jr. A microleakage study of temporary restorative materials used in endodontics. J Endod 1989;15: 569-72. 19. Abramovitz L, Lev R, Fuss Z, Metzger Z. The unpredictability of seal after post space preparation: a fluid transport study. J Endod 2001;27:292-5. 72