AT89C51 Microcontroller Based Control Model for Hybrid Assistive Limb (Knee )

Similar documents
EMG-Driven Human Model for Orthosis Control

Electromyogram-Assisted Upper Limb Rehabilitation Device

Study on the control of variable resistance for isokinetic muscle training system

DESIGN AND IMPLEMENTATION OF A MECHATRONIC SYSTEM FOR LOWER LIMB MEDICAL REHABILITATION

Sign Language Interpretation Using Pseudo Glove

AVR Based Gesture Vocalizer Using Speech Synthesizer IC

DEVICE FOR MUSCLE COORDINATION IMPROVEMENT

A study of the relationship between sit-to-stand activity and seat orientation

FUSE TECHNICAL REPORT

A NOVEL ALGORITHM TO PREDICT KNEE ANGLE FROM EMG SIGNALS FOR CONTROLLING A LOWER LIMB EXOSKELETON

Navigator: 2 Degree of Freedom Robotics Hand Rehabilitation Device

l. Initiate early proprioceptive activity and progress by means of distraction techniques: i. eyes open to eyes closed ii. stable to unstable m.

Verification of Passive Power-Assist Device Using Humanoid Robot: Effect on Bending and Twisting Motion

Design and Control of a Robotic Assistive Device for Hand Rehabilitation (RAD-HR)

Automated Syringe-Loading Device

DEVELOPMENT OF WEARABLE MASTER-SLAVE TRAINING DEVICE FOR UPPER LIMB CONSTRUCTED WITH PNEUMATIC ARTIFICIAL MUSCLES

Android based Monitoring Human Knee Joint Movement Using Wearable Computing

Smart Suit Lite: KEIROKA TechnologyPaper Title

Verification of Assistive Effect Generated by Passive Power-Assist Device Using Humanoid Robot

Exoskeletons: Reducing joint and muscle loads while performing difficult tasks

CHAPTER 11 UNIVERSITY OF DENVER

Q: What is the relationship between muscle forces and EMG data that we have collected?

What is a stepper motor?

TRANSFORMER ALL IN ONE ISOKINETIC MACHINE ANKLE ELBOW HIP SHOULDER WRIST TRUNK

Squid: Exercise Effectiveness and. Muscular Activation Tracking

Leg Control based on Human Motion Prediction Using Motion Sensor for Power Assist Suit without Binding Knee

3-DOF Parallel robotics System for Foot Drop therapy using Arduino

Design and Analysis of Automatic Insulin Delivery System Using Pic Microcontroller

A Measurement of Lower Limb Angles Using Wireless Inertial Sensors during FES Assisted Foot Drop Correction with and without Voluntary Effort

DEVELOPMENT AND CONTROL OF A 3DOF UPPER-LIMB ROBOTIC DEVICE FOR PATIENTS WITH PARETIC LIMB IMPAIRMENT

New methods for the simulation with finite element of the human elbow

A Review on Hand Gesture Recognition for Deaf and Dumb People Using GSM Module

Measuring Heart Rate and Blood Oxygen Levels for Portable and Wearable Devices

CONTROL OF THE BOUNDARY CONDITIONS OF A DYNAMIC KNEE SIMULATOR

Measurement of Soft Tissue Deformation to Improve the Accuracy of a Body-Mounted Motion Sensor

Five-Fingered Assistive Hand with Mechanical Compliance of Human Finger

Estimation of the Upper Limb Lifting Movement Under Varying Weight and Movement Speed

Development of an Electronic Glove with Voice Output for Finger Posture Recognition

KINEMATIC ANALYSIS OF ELBOW REHABILITATION EQUIPMENT

About the Simulation of the Human Knee Joint for Walking Locomotion

REHABILITATION ENGINEERING RESEARCH CENTER TECHNOLOGIES FOR CHILDREN WITH ORTHOPAEDIC DISABILITIES

IMPROVEMENT OF PNEUMATIC FOOTBALL KICKING DEVICE BASED ON IMITATION OF HUMAN DYNAMICS

Smart Speaking Gloves for Speechless

AN EXOSKELETAL ROBOT MANIPULATOR FOR LOWER LIMBS REHABILITATION

A hybrid approach for identification of root causes and reliability improvement of a die bonding process a case study

Basics of kinetics. Kinesiology RHS 341 Lecture 7 Dr. Einas Al-Eisa

Design and Modeling of an Upper Extremity Exoskeleton

WEARABLE MASTER-SLAVE TRANING DEVICE FOR LOWER LIMB CONSTRUCTED WITH PNEUMATIC RUBBER ARTIFICIAL MUSCLES

Research on Digital Testing System of Evaluating Characteristics for Ultrasonic Transducer

Wearable Hand Rehabilitation Robot Capable of Hand Function Assistance in Stroke Survivors*

Accelerometer based human joints' range of movement measurement

Beyond the Bar Graph: Visual Presentation of Results

MPFL RECONSTRUCTION. This procedure is recommended for patients who have had multiple kneecap dislocations.

Estimation of Energy Consumption when Wearing Power Assist Suits

General Treatment Equipment

Exoskeleton : Market Shares, Strategies, and Forecasts, Worldwide, 2015 to 2021

TORQUE CONTROL OF AN EXOSKELETAL KNEE WITH EMG SIGNALS

The ADL Force 5 configured for knee testing

Development of a 6DOF Exoskeleton Robot for Human Upper-Limb Motion Assist

Design Considerations of a Human Arm Exoskeleton

human-centered exoskeleton design

Chapter 6. Results. 6.1 Introduction

1. EXECUTIVE SUMMARY 2. PRODUCT SUMMARY

Modeling And Biomechanical Analysis Of Human Knee Joint

Analysis of Human Standing-up Motion Based on Distributed Muscle Control

IDENTIFICATION OF INTERNAL LOADS AT THE SELECTED JOINTS AND VALIDATION OF A BIOMECHANICAL MODEL DURING PERFORMANCE OF THE HANDSPRING FRONT SOMERSAULT

Design and Dynamic Modeling of Flexible Rehabilitation Mechanical Glove

Current Usage Reduction Through Stiffness Control in Humanoid Robot

Verification of Immediate Effect on the Motor Function of a Plegic Upper Limb after Stroke by using UR-System 2.2

Recognition of Voice and Text Using Hand Gesture

4.2 Fatigue at Joint Level versus Fatigue at Muscle Level

Test Method for Contact Safety Assessment of a Wearable Robot -Analysis of Load Caused by a Misalignment of the Knee Joint-

ON A MECHATRONIC SYSTEM TO DETERMINE DYNAMIC PARAMETERS OF THE HUMAN LIMB DURING LOCOMOTION USED FOR ARTIFICIAL MUSCLES AND IMPLANT DESIGN

Patient Simulator Using Wearable Robot to Estimate the Burden of Knee-Osteoarthritis Patients during Sitting-down and Standing-up Motions

EMBEDDED PROJECTS-IEEE-NON IEEE DOMAINS

A Design of Prototypic Hand Talk Assistive Technology for the Physically Challenged

Anatomy, Biomechanics, Work Physiology, and Anthropometry. After completing and understanding of the current chapter students should be able to:

The application of New Technologies in Podiatry. Dr Alfred Gatt PhD FFPM RCPS (Glasg.) Podiatry Department University of Malta

CHAPTER 18 UNIVERSITY OF WISCONSIN AT MILWAUKEE

BIOMECHANICAL EVALUATION OF DEGREE OF FREEDOM OF MOVEMENTS OF AN NOVEL HIGH FLEXION KNEE FOR ITS SUITABILITY IN EASTERN LIFESTYLES

Self-Transfer Assistive Device for Hip and Knee Replacement Patients

REHABILITATION IN VIRTUAL REALITY VAST.REHAB IS DESIGNED FOR PHYSICAL, OCCUPATIONAL AND COGNITIVE THERAPY

Embedded Based Hand Talk Assisting System for Dumb Peoples on Android Platform

Maximal isokinetic and isometric muscle strength of major muscle groups related to age, body weight, height, and sex in 178 healthy subjects

EasyChair Preprint. Lower Body Passive Exoskeleton Using Control Enabled Two Way Ratchet

BLOOD GLUCOSE LEVEL MONITORING BY NONINVASIVE METHOD USING NEAR INFRA RED SENSOR

Figure 1: Weight bearing apparatus to measure knee contact area.

Treatment Equipments. We have quality products in Treatment Equipments. All our models are efficient and display quality in Physiotherapy Equipments.

What is Kinesiology? Basic Biomechanics. Mechanics

International Journal of Advance Engineering and Research Development. Gesture Glove for American Sign Language Representation

Communication Interface for Mute and Hearing Impaired People

Design of the HRV Analysis System Based on AD8232

X-ray (Radiography) - Bone

A Review on Gesture Vocalizer

Biomechanics. MCE 493/593 & ECE 492/592 Prosthesis Design and Control September

Leg Rehabilitation Device for Paralysis Patients

Wheelchair Seating: Are We Speaking the Same Language?

Project: Feedback Systems for Alternative Treatment of Obstructive Sleep Apnea

Research & Development of Rehabilitation Technology in Singapore

rapael smart rehab solution

Transcription:

From the SelectedWorks of suresh L Winter January 10, 2013 AT89C51 Microcontroller Based Control Model for Hybrid Assistive Limb (Knee ) suresh L Available at: https://works.bepress.com/suresh_l/2/

AT89C51 Microcontroller Based Control Model for Hybrid Assistive Limb (Knee ) L.Suresh 1, G.R.S. Naga Kumar 2, M.V.Sudarsan 3 1,2,3 Asst. professor, Department of Electrical & Electronics Engineering Vignan s Lara Institute of Technology & Science Vadlamudi, Andhra Pradesh, INDIA suresh.201@gmail.com Abstract In this paper, a controlling system is implemented for a wearable walking supporting device so called as Hybrid Assistive Limb. The control circuit is implemented without considering the biological signals of the human body for the knee part, which is based on the knee joint moment from the human body model. The control and a driving circuits are implemented to assistive the knee as for the requirement of knee joint dynamics. Keywords HAL, Control circuit, Knee dynamics, Driving circuit I. INTRODUCTION Till now different types of the walking supporting devices are cranes, caster walks, walking frames etc. has been produced and commercially available. In addition this some actuated walking supporting devices are developed, in which some kinds of motors like DC, stepper and servo motors are used to provide support to the different parts of the human body. The main application of the walking supporting system is to provide free movement of the people who are physically disabled and reducing the load on their muscles. But the main problem with this passive walking support system is, they restrict the daily activities and free mobility of the users. Some wearable robot systems have been developed so far [1] [2] [3] [4], In most of these wearable supporting systems, supporting muscular force or necessary supporting force/moment of the system is controlled based on the current human muscular force estimated by biological signals or phenomena such as EMG (electromyogram) signals. The output forces of human muscles, however, could not be estimated in real time based on the biological signals, because these biological signals are emitted by the result of the activation of muscles [5]. In this a micro controller-based control circuit is proposed to supporting joint moment without using biological signals and the work mainly concentrates on the knee part of the human body. In the proposed circuit, the human model estimates the knee joint moment. In order to provide support to the knee stepper motors are provided. In the following part of this paper, we first introduce a prototype model of the Hybrid Assistive Limb. This is the wearable supporting device for walking and then proposed a control circuit for Hybrid Assistive Limb. Finally, experimental results conducted on the controlling circuit are illustrated. A. Introduction: II. HYBRID ASSISTIVE LIMB Hybrid assistive limb (HAL) systems are having a lot of importance in the area of medical applications. So there exists significant importance in these areas of research, since the human system is the most complicated automatic control system in the universe. HAL expected to be applied in various fields such as rehabilitation support and physical trainee support in medical field. It is also expected that the device gives substantial help for disable people for moving the completion of their daily life activities. It may also provide heavy labor support at factories, rescue support at deserts etc. in entertainment area also some expected. The main parts in the HAL system are, 1. Ankle 2. Knee 3. Hip 4. Shoulder 5. Elbow 6. Rist But, here the work mainly concentrates on the knee part of the HAL system. B. Knee The knee joint is the most problematic joint. Common injuries include ligament injuries, meniscus tear and unstable kneecap. Diseases like arthritis at the knee are also a common problem especially among the elderly people. Treatments of knee injuries and diseases will require proper resting of the knee and reducing the pressure acting on the knee joint. This helps to reduce the stress on the ligaments, cartilage, muscles and bones to accelerate the healing process. Current methods to achieve pressure reduction at the knee include the use of crutches, walkers, canes or even wheelchair [5]. C. Prototype model: Figure 1(a) shows the developed prototype of the Hybrid Assistive Limb, and Figure 1(b) illustrates the mechanism of the knee joint of the device. This device is developed taking into account of the knee structure, and has 1

one degree of freedom, that is, rotation around knee joint on sagittal plane, because in walking the motion of the knee joint is only rotation. Hybrid Assistive Limb consists of the geared dual hinges, a stepper motor, and a potentiometer attached to the knee joint of the user. III. CONTROL CIRCUIT OF HYBRID ASSISTIVE LIMB A control circuit of Hybrid Assistive Limb is designed in this section. Figure 2 shows the control circuit of the Hybrid Assistive Limb. In this figure, the main parts are potentiometer, Micro controller and the stepper motors. First, each joint angle is measured by considering the kinematics and dynamics of the human knee. By using a potentiometer the joint angle of the human knee is converted to analog signal that is shown in the figure 5 and then it is applied to the micro controller. Fig.2. Controller Circuit The functionally of the ADC 0808 is to convert the Analog signals to digital that are coming form the potentiometer. The driver circuit is provided in order to drive the stepper motors and also used as a isolator for isolating the stepper motor and micro controller unit. Fig. 1. (a) Hybrid Assistive Limb Fig.1. (b) Knee Mechanism Based on the joint angle the micro controller generates controlling pulses that are shown in figure 6. Finally, the actuator or stepper motor generates the joint moment and help the user to walk. IV. KINEMATICS AND DYNAMICS Several kinds of wearable robot systems have been developed for supporting walking. These systems generate supporting force/moment for walking based on real-time estimation of current muscular force. In most of these systems, the muscular force is estimated based on biological signals such as EMG signal. How ever, the output force of human muscle could not be estimated by the result activation of the muscles. In this section the joint angle is measured based the model of human, and we introduced the dynamic equations in order to determine the joint angle. A. Human Model: Figure 3 shows the simplified model of the human body for calculating the joint moment. The model consists of four links and three hinge joints; a foot link, a shank link, a thigh link, an upper body link, an ankle joint, a knee joint, and a hip joint. The kinematics of the human knee is as follows, 1. Kinematic modeling 2. Dynamic modeling Steps for kinematic modeling: 1. Assign the frame for each joint. Denote the fixed joint as zeroth frame. 2. Tabulate the DH (Denavit - Hartenberg) parameter table. 3. Formulate the basic transformation matrix and hence find out the final link transformation matrix. 2

4. Equate the transformation matrix with the position matrix and solve for the unknowns DH parameter table: Ө d a α 0T1 Ө 0 1 0 Fig.4. Experimental set up Where, Ө - Rotation about Z-axis d - Translation along Z-axis a - Translation along X-axis α - Rotation about X-axis By equating the values from the transformation matrix, the position and orientation of the end effectors can be calculated. The dynamic model of the human knee is based on Lagrange Euler formulation is obtained from the Lagrange equations. V. EXPERIMENTS The Hybrid Assistive Limb is controlled by using stepper motors and is controlled by a driving circuit in open loop mode. The stepper motors are mostly used for position and velocity control in the robotic applications, and also it provides torque, which is independent of the load. Stepper motor is controlled in open loop so there is no control over the position of the stepper motor and there should be always an error in the position of the motor shaft. Fig.5. Analog signal of Knee joint angle Fig.6. Controlling pulses Fig.3. Human Model [5] So in order to find out the position error, the following circuit arrangement shown in figure 4 is used. For measuring the error a multi turn potentiometer is used and it is coupled to the shaft of the stepper motor by using a shaft coupler. The experimental set up consists of stepper motor and a potentiometer. The potentiometer is used to measure the error in the position of the motor shaft. The table I show the experimental results of the above arrangement VI. SOFTWARE DESCRIPTION So far the topic mainly concentrates in the detailed description about the hardware, its operation and analysis. But one factor is not at all mentioned anywhere in the previous discussions. It is nothing but the software modules 3

and programming part. It is to be noted that the successful operation of the micro controller mainly depends upon the software. It has to be programmed properly for the successful control of the knee part of the Hybrid Assistive Limb. The detailed description about the software part is considered below. This description is purely about the programming of the micro controller. In this paper, Keil Software (C51) is used to develop the data logger circuit. Keil compiler is a cross compiler which is used to compile that code designed for different chips on host machine and to get the hex code. General procedure in working with Keil compiler as follows: 1. Create source file in 'C' or assembly. 2. Compile or assemble source files. 3. Correct errors in source files. 4. Load the.hex file into Micro controller Flash Memory with the help of Programmer. S.NO. Measur ed Voltage (Volts) TABLE I Error Comparison Angle Corresponding Voltage Actual angle Error 1 0.08 5.76 7.2 1.44 2 0.175 12.6 14.4 1.8 3 0.28 20.16 21.6 1.44 4 0.6 43.2 45 1.8 VII. SUMMARY AND CONCLUSION In the present work the knee joint angle is measured without considering the biological signals and simplified human body dynamics. A detailed review, presenting the important work going on the Hybrid Assistive Limb area, has been given at the beginning. This has been given with a view to enlighten the reader with the significance of this type of work in the modern medical applications. A detailed description about the control of the Hybrid Assistive Limb is given next. The type of driving systems, moving mechanism, micro controllers used for the purpose are given. Suggestions for future work is the knee joint angle can be measured by considering the biological signal i.e. by placing a sensor near the knee joint the angle can be measured. APPENDIX Stepper motor parameters: Type bipolar winding Rated voltage 12V DC Rated current 0.6 AMP Step angle 1.8 degrees ACKNOWLEDGMENT We are very much thank to Abhilash S, completed his M. Tech in MECHNICAL ENGINEERING from NIT Calicut in 2010, for his suggestions and his work in the development of prototype model for the Hybrid Assistive Limb. REFERENCES [1] http://www.technovelgy.com/ct/science-fiction-news.akrod, Active Knee Rehabilitation Device Human Trials. [2] http://yobotics.com/robowalker/robowalker.html. [3] Cybernics Laboratory, University of Tsukuba. 2005. Robot Suit HAL. http://sanlab.kz.tsukuba.ac.jp/hal/indexe.html. [4] Berkeley Robotics and Human Engineering Laboratory. 2003. Berkeley Robotics Laboratory, BLEEX Project. http://bleex.me.berkeley.edu/bleex.htm. [5] Model-based walking support system with Wearable Walking Helper by Takahiko Nakamura and Kazuhiro Kosuge, Proceedings of the 2003 IEEE International Workshop on Robot and Human Interactive Communication Millbrae, Caliiomia. USA, Oct. 31 -Nov. 2.2003. [6] Providing assistance to knee in the design of a portable active orthotic device by K. H. Low, Yuehong Yin and Shanghai Jiao, Proceeding of the 2006 IEEE International Conference on Automation Science and Engineering Shanghai, China, October 7-10, 2006. [7] Realizing a Posture-based Wearable Antigravity Muscles Support System for Lower Extremities by Takahiko Nakamura, Kazunari Saito, ZhiDong Wang and Kazuhiro Kosuge, Proceedings of the 2005 IEEE 9th International Conference on Rehabilitation Robotics June 28 - July 1, 2005, Chicago, IL, USA. [8] Control Method of Robot Suit HAL working as Operator's Muscle using Biological and Dynamical Information by Tomohiro Hayashi, Hiroaki Kawamoto and Yoshiyuki Sankai, Graduate School of Systems and Information Engineering University of Tsukuba, Japan [9] Stepping Motors Fundamentals, Author Reston Condit, Microchip Technologies and Dr. Douglas W. Jones, University of Lowa. [10] ATMEL AT89C52-8-bit micro controller with 8K bytes in system programmable Flash- Data Sheet. 4