DISTAL RADIUS. Instructions for Use

Similar documents
Lapidus Arthrodesis System Instructions for Use

Pinit Plate Small Bone Fusion System Bone Plate & Screw System

For the Attention of the Operating Surgeon: IMPORTANT INFORMATION ON THE MATRIXRIB FIXATION SYSTEM

Conventus CAGE PH Surgical Techniques

Revision A Date:

JRI Thompson Hemiarthroplasty

Technique Guide KISSloc Suture System

MRI Information for Medtronic Spinal and Biologics Devices

D. The following factors are of extreme importance to the eventual success of the procedure.

Technique Guide Small Bone Fusion System

Page 1 of 7 Doc. No.: IU/15 Rev. No.: 05 Rev. Date:03MAY2018. Instructions for use for ATLAS Tibial Fracture(TF) Nail

IMPORTANT MEDICAL INFORMATION Advanced Orthopaedic Solutions INTRAMEDULLARY NAILS Warnings and Precautions (SINGLE USE ONLY)

METAL HEMI SYSTEM

Yasargil Permanent Aneurysm Clips

EasyStep. Operative technique

TC-PLUS Primary Knee IMPORTANT MEDICAL INFORMATION SPECIAL NOTE. This Package Insert is for product distributed in the US only.

Low-Profile Wrist Fixator. For stabilization of fractures of the distal radius.

CELLPLEX TCP SYNTHETIC CANCELLOUS BONE

Customized Cranial and Craniofacial Implants. Instructions For Use. 7000revD_Instructions_For_Use. Page 1 of 8

Important Information on ATLAS Hip Fracture Nail For use by an Accredited Orthopaedic Surgeon only

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

External Distal Radius Fixator. Supplement to the 8 mm rod fixator system

PRO-DENSE Bone Graft Substitute The following languages are included in this packet:

PRO-DENSE BONE GRAFT SUBSTITUTE

Medium External Fixator Humeral Shaft Frame. Modular frame for upper extremity use.

INTELLIGENT SPINAL SYSTEM

Instructions for use Prodisc -C Vivo Cervical disc prosthesis

LBL-014. Rev

Aesculap CeSpace TM PEEK and CeSpace TM XP Spinal Implant System Instructions for Use

WallFlex Biliary RX Partially Covered Stent System Prescriptive Information

Distal Radius Plate 2.4/2.7 dorsal and volar

EVOLVE TRIAD BONE SCREWS

FastFrame External Fixation System. Damage Control Surgical Technique

Metallic Internal Fixation Devices The following languages are included in this packet:

Precautionary Statement ( )

Allium Trans-hepatic Biliary Stent (BIS)

Radux StandTall Instructions for Use Sheath Extender and Securement Clasp

IPP-ON. Interphalangeal implant. Surgical Technique. l o w e r e x tre mit y. Or t h o pa e d i c s. IPP-ON English

TriboFit Hip System. Issue 3 - August 2013 English

For use by an Accredited Orthopaedic Surgeon only

Medium External Fixator Pediatric Femoral Shaft Frame. Using medium multi-pin clamps.

Technique Manual Technique Manual Rev. A 01/11/2011

Ceramic Femoral Heads and Acetabular Cup Liners

LCP Metaphyseal Plates. For extra-articular fractures.

Technique Guide Lapidus Arthrodesis System

OPERATIVE TECHNIQUE. CONSTRUX Mini PTC. Mini PTC Spacer System

Flexible Fragment Fixation. Surgical Technique

Cervical Screw System

The following languages are included in this packet:

Device Preparation (all steps to be performed per standard interventional technique)

TABLE OF CONTENTS. 2 (8144 Rev 2)

Document No Rev. B Pg. 1 of 5 Approvals / Date Title: INSTRUCTIONS FOR USE DJO SURGICAL MODULAR REVISION HIP SYSTEM AND ACETABULAR CAGE

The following languages are included in this packet:

BONE GRAFT WASHER _Rev A IMPORTANT INFORMATION ON THE BONE GRAFT WASHER

SIDEKICK EZ FRAME EXTERNAL FIXATION SYSTEM The following languages are included in this packet:

X-spine Systems, Inc. Butrex Lumbar Buttress Plating System

Surgical Technique Guide

AXS Catalyst Distal Access Catheter

Zimmer Anterior Buttress Plate System. Surgical Technique

Headless Compession Screw 2.5 / 3.0

North Medical Endoscopic Biliary Stent (BilS)

Headless Compession Screw 4.5 / 6.5 SURGICAL TECHNIQUE. Titanium or Stainless Steel. Cannulated Headless Design. Multiple Thread Options.

Table of Contents.

Low Profile Neuro Plating System. Surgical Technique

CAUTION Federal law (USA) restricts this device to sale, by or on the order of a physician.

Cardiva Catalyst III INSTRUCTIONS FOR USE

SURGICAL TECHNIQUE GUIDE: JONES FRACTURE USING THE PRECISION JONES FRACTURE SCREW SYSTEM

Indications: ATLAS HF Nail is indicated for fractures of the femur including: Contraindications:

The Calcaneal Plate. The Synthes non-locking solution for the Calcaneus.

EVOLVE TRIAD SYSTEM

Visit Linvatec.com today to learn more. Surgical Technique: Sequential Meniscal Running Stitch

DISCLAIMER OF WARRANTY AND LIMITATION OF REMEDY

Button Plate. Reinforcement for transosseous fixations.

EXTERNAL FIXATION SYSTEMS The following languages are included in this packet:

Integra Flowable Wound Matrix

Endorectal Balloon (ERB) Endorectal Balloon (ERB) Instructions for Use

OBSOLETED. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Instructions for use for Bone Plates, Bone Screws, Intramedullary Nails, Pins and Wires

Patient Information ACDF. Anterior Cervical Discectomy and Fusion

LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius.

SYMBOLOGY. = Manufacturer. = Manufacturing Serial Number. = Manufacturing Lot Number = Catalog Number LOT REF. = Do not resterilize Single Use Only

Duraloc CONSTRAINED LINER

Sterile-Packaged Large External Fixator Kits. For treatment of long bone and pelvic fractures that require external fixation.

NEO PEDICLE SCREW SYSTEM V. 2.0

ACP1 CERVICAL PLATE SPINAL SYSTEM SURGICAL TECHNIQUE GUIDE II.

nvp Posterior Lumbar Interbody Fusion System

nvt Transforaminal Lumbar Interbody Fusion System

Doc. No.: IU/8 for. Rev. No.: 07 ResTOR Prosthesis

WristMotion Wrist Hemiarthroplasty System Instructions for Use

3.5 mm LCP Olecranon Plates

ENDO-FUSE INTRA-OSSEOUS FUSION SYSTEM The following languages are included in this packet:

nva Anterior Lumbar Interbody Fusion System

MetaFix Ludloff Plate

ORTHOLOC 3Di PLANTAR LAPIDUS PLATE

SYNPOR POROUS POLYETHYLENE IMPLANTS. For craniofacial and orbital augmentation and reconstruction

Cervical Spacer System surgical technique

Amendia Interbody Fusion Devices PACKAGE INSERT

MRI GUIDELINES FOR INSPIRE THERAPY

Transcription:

DISTAL RADIUS Instructions for Use

CAUTION: FEDERAL LAW RESTRICTS THESE DEVICES TO SALE BY OR ON THE ORDER OF A PHYSICIAN. Table of Contents 1. INTENDED USE... 3 2. DEVICE DESCRIPTION... 3 3. METHOD OF IMPLANTATION... 3 4. CONTRAINDICATIONS... 3 5. WARNINGS AND PRECAUTIONS... 3 6. OPERATIVE PRECAUTIONS... 5 7. MRI SAFETY INFORMATION... 5 8. PRODUCT COMPLAINTS... 6 9. STORAGE INSTRUCTIONS... 6 10. WARRANTY... 6 11. FURTHER INFORMATION... 6 Doc No 1700 Rev 3 Page 2 of 8

1. INTENDED USE The Conventus CAGE TM Distal Radius is intended for the fixation of distal radius fractures. 2. DEVICE DESCRIPTION The Conventus CAGE TM Distal Radius (DR CAGE) is an expandable implant which is deployed into the intramedullary canal of the distal radius and provides a scaffold to which bone fragments can be attached using fragment screws. The DR CAGE is flexible during device placement, but once deployed creates a stable bone-implant construct at the completion of the surgical implantation procedure. The DR CAGE is comprised of an Expandable Scaffold (Inner Scaffold, Outer Scaffold, Central Member), Fragment Screws, Proximal Plate and Fragment Screws in a proximal location. All components of the system are made of known biocompatible materials as listed in Table 1. Table 1. Components and Materials of the DR CAGE Component Material and Standard Expandable Scaffold Scaffolds: Nitinol (ASTM F2063) Central Member: (ASTM F136) Fragment Screws Titanium alloy (ASTM F136) Proximal Plate Titanium alloy (ASTM F136) 3. METHOD OF IMPLANTATION Please see the DR CAGE Surgical Technique Manual for a more-detailed description of the implantation procedures. The surgical technique includes the following general steps: 3.1. Reduce and stabilize fracture. 3.2. Template and size implant location. 3.3. Insert guide pin at entry point. 3.4. Prepare cavity for DR CAGE. 3.5. Insert and lock Expandable Scaffold. 3.6. Secure bone fragments with Fragment Screws into Expandable Scaffold. 3.7. Attach Proximal Plate. 3.8. Close. 4. CONTRAINDICATIONS The DR CAGE should not be implanted in patients with: active infections at the operative site or other active systemic infection suspected or known sensitivity or allergies to Nickel or Titanium mental conditions that preclude cooperation with the rehabilitation regimen 5. WARNINGS AND PRECAUTIONS Warnings: 5.1. Fracture fixation devices are neither intended to carry the full load of the patient, nor intended to carry a significant portion of the load for extended periods of time. 5.2. Do not use the DR CAGE with components from other manufacturers. Use only Conventus Orthopaedics devices. Precautions: 5.3. Use care in handling and storage of implant components. Cutting, sharply bending or scratching the surface can significantly reduce the strength and fatigue resistance of the implant system. This, in turn, could induce cracks and/or stresses that could lead to fracture of the implants. Doc No 1700 Rev 3 Page 3 of 8

5.4. Additional surgical technique information is available upon request. The surgeon should be familiar with the devices, instruments and surgical technique before surgery. 5.5. Please refer to the surgical technique manual for proper implantation procedures. 5.6. The surgeon should take care with patient selection and avoid patients with insufficient quality of bone, an obliterated medullary canal or conditions which tend to retard healing, including but not limited to, blood supply limitations or previous infections. 5.7. Postoperative instructions to patients and appropriate nursing care are critical. Early weight bearing substantially increases implant loading and increases the risk of loosening, bending or breaking the device. Early weight bearing should only be considered where there are stable fractures with good bone-to-bone contact. Patients who are obese and/or noncompliant, as well as patients who could be pre-disposed to delayed union or non-union, must have auxiliary support. 5.8. Even after full healing, the patient should be cautioned that refracture is more likely with the implant in place and soon after its removal, rather than later when voids in the bone left by implant removal have been filled in completely. 5.9. Patients should be cautioned against unassisted weight-bearing activity without physician direction or medical release. 5.10. Postoperative care and physical therapy should be structured to prevent loading of the radius until stability is evident. Potential adverse events may be related to surgery in general or the device. These may include, but are not limited to the following: Potential adverse events related to any surgery: reactions to anesthesia, the anesthetic or other medications, bleeding, infection (both deep and superficial), ileus, blood vessel damage, nerve or soft tissue damage, atelectasis, pneumonia, hematoma, seroma, wound dehiscence or incisional hernia, urologic problems, embolism, anemia, colitis, thrombophlebitis, heart attack, stroke or death. Potential adverse events related to the device: bending, cracking or fracture of the implant components, failure to achieve fracture healing, or loosening of the implant, limb shortening or loss of anatomic position with nonunion, malunion with rotation or angulation, irritational injury of soft tissues, including impingement syndrome, or tissue reactions which include macrophage and foreign body reactions adjacent to implants. Metal sensitivity or histological or allergic reaction resulting from implantation of a foreign material may occur. Additional surgery may be necessary for implant removal, repositioning or replacement. The Expandable Scaffold and Delivery System of the DR CAGE are provided sterile. Each package should be inspected prior to use to ensure package integrity prior to use. Do not resterilize implants or single-use accessories if the package has been opened but the implant is not used. Fragment Screws and the Proximal Plate are provided NON-STERILE in an autoclavable tray and must be sterilized prior to use according to the one of the following cycles: Cycle Minimum Minimum Minimum Exposure Time Temperature Drying Time Gravity Autoclave 30 Minutes 132 C 20 Minutes Pre-vacuum Autoclave 4 Minutes 132 C 20 Minutes Pre-vacuum Autoclave 3 Minutes 135 C 20 Minutes All implants should be inspected prior to use for possible damage or defects. Any damaged or defective component should not be used and should be returned to the manufacturer. If an implant has been contaminated by blood or secretions, clean and steam sterilize the implant prior to returning it to the manufacturer. The manufacturer is not responsible for any complications arising from incorrect diagnosis, incorrect choice of implant, incorrect operating techniques, the limitations of treatment methods or inadequate asepsis. During the post operative phase, in addition to mobility and muscle training, it is of particular importance that the physician keeps the patient well informed about post-surgical activity requirements. Doc No 1700 Rev 3 Page 4 of 8

6. OPERATIVE PRECAUTIONS The surgeon is to be thoroughly familiar with the DR CAGE, method of implantation, instruments and surgical technique. Proper surgical procedures and techniques are the responsibility of the medical professional. Each surgeon must evaluate the appropriateness of the procedures based on his or her personal medical training and experience. The implants are for single-implant use only. An explanted device must never be reimplanted. 7. MRI SAFETY INFORMATION MRI Safety Information MR Conditional Non-clinical testing demonstrated that the DR CAGE is MR Conditional. A patient with this device can be scanned safely, immediately after placement under the following conditions: Static magnetic field of 1.5-Tesla and 3-Tesla, only Maximum spatial gradient magnetic field of 4,000 gauss/cm (40 T/m) Maximum MR system reported, whole body averaged specific absorption rate (SAR) of 2.0-W/kg for 15 minutes of scanning (i.e., per pulse sequence) Normal Operating Mode of operation for the MR system MRI-Related Heating In non-clinical testing, the DR CAGE produced a temperature rise of less than 3 o C under the scan conditions defined above in a 1.5-Tesla/64-MHz (Magnetom, Siemens Medical Solutions, Malvern, PA. Software Numaris/4, Version Syngo MR 2002B DHHS Active-shielded, horizontal field scanner) MR Scanner. In non-clinical testing, the DR CAGE produced a temperature rise of 2 o C under the scan conditions defined above in a 3-Tesla/128-MHz (Excite, HDx, Software 14X.M5, General Electric Healthcare, Milwaukee, WI) MR Scanner. Artifact Information MR image quality may be compromised if the area of interest is in the exact same area or relatively close to the position of the DR CAGE. Therefore, optimization of MR imaging parameters to compensate for the presence of this device may be necessary. The image artifact extends approximately 10mm from the device, when scanned in nonclinical testing using a gradient echo pulse sequence at 3-Tesla (Excite, HDx, Software 14X.M5, General Electric Healthcare, Milwaukee, WI). Doc No 1700 Rev 3 Page 5 of 8

8. PRODUCT COMPLAINTS Any healthcare professional (e.g., a surgeon using the product) who has a complaint or who has experienced any dissatisfaction in the quality, identity, reliability, safety, efficacy, and/or performance of any Conventus product should notify Conventus Orthopaedics, or, where applicable, their distributor. In the event of serious incident, or risk of serious incident, having resulted in, or may potentially result in, the death or severe deterioration in the state of health of a patient or user, Conventus Orthopaedics or the distributor must be notified as soon as possible. When filing a complaint, please provide the component(s) reference number (model number), manufacturing lot number(s), your name and address, and the nature of the complaint in full detail, as well as notification of whether a written report is requested. 9. STORAGE INSTRUCTIONS Store in a cool dry place and keep away from direct sunlight. Prior to use, inspect instruments and tray for signs of tampering. 10. WARRANTY THE COMPANY REPRESENTS AND WARRANTS THAT THE DR CAGE WILL CONFORM TO THE COMPANY S SPECIFICATIONS AND COMPLY WITH ALL APPLICABLE FDA STANDARDS, AS SUCH STANDARDS MAY BE AMENDED FROM TIME TO TIME. THE COMPANY MAKES NO OTHER EXPRESS OR IMPLIED WARRANTIES REGARDING THE DR CAGE. 11. FURTHER INFORMATION For further Information, please contact: Conventus Orthopaedics, Inc. 10200 73 rd Avenue North, Suite 122 Maple Grove, MN 55369 Phone: 763-515-5000 Fax: 763-315-4980 www.conventusortho.com Doc No 1700 Rev 3 Page 6 of 8

This page intentionally left blank Doc No 1700 Rev 3 Page 7 of 8

Caution: Federal Law (USA) restricts this device to sale by or on the order of a physician. REF Model /Part Number LOT Lot Number Use Before Date Quantity Material Caution, consult accompanying documents Single Use Only STERILE R Contents Sterile: Irradiation Contents are Non-Sterile Manufacturer MR Conditional Doc No 1700 Rev 3 Page 8 of 8