Customer: Stud Horse Mountain Extracts Type: Concentrate Instrument: HPLC-PDA Submitted: 09/22/17

12025 NE Marx St. Portland, OR Green Leaf Lab proudly follows / ISO/IEC 17025:2005(E) Quality Standards

Analytical Results SC Laboratories Oregon LLC ORELAP# 4133/OLCC# D SW 74th Ave Suite 110, Tigard, OR

Brian C. Smith, Ph.D. Chief Technical Officer Big Sur Scientific (508)

Agilent GC-MS: Headspace-GC-MS systems for the analysis of Residual Solvents and Terpenes

Analytical Results SC Laboratories Oregon LLC ORELAP# 4133/OLCC# D SW 74th Ave Suite 110, Tigard, OR

Analytical Results SC Laboratories Oregon LLC ORELAP# 4133/OLCC# D SW 74th Ave Suite 110, Tigard, OR

CANNABIS ANALYTICS. Toward a Chemotype-Based Labeling System

C4 Laboratories, LLC 1930 S. Alma School Rd Suite B202 Mesa, AZ "Patient protection through true science" Dear Valued Colleague,

Simplified Cannabis Terpene Profiling by GCMS

Determination of Cannabinoid and Terpene Profiles in Cannabis Oils by Mid-Infrared Spectroscopy: 1. Cannabinoids

Cannabis Reference Standards

2017 STYLE GUIDELINES & GROWERS MANUAL PHOTO COURTESY EAST FORK CULTIVARS

Certificate of Analysis

ANALYSIS OF DATA GENERATED BY EXCELSIOR ANALYTICAL LABS NOVEMBER 4, 2015

Key Advantages of Comprehensive Cannabis Analysis

Customer Sample Type Method Technique

CANNABIS: BEYOND THE PLANT OVERVIEW

Residual Solvents in medical cannabis analysis using the SRI 8610C FID GC Jan 2017

I. WELCOME TO YOUR CANNAGX REPORT 1 II. SUMMARY OF HOW YOUR BODY REACTS TO CANNABIS 2 III. SUMMARY OF YOUR PERSONAL PRODUCT SELECTION 3

GC/MS BATCH NUMBER: O10106

Customer : Comments and Conclusions : Daniel Dantin - Laboratory director

Cannabis Testing Laboratory Solutions

Medicinal Marihuana Science, Redefined

GC/MS BATCH NUMBER: L70106

CERTIFICATE OF ANALYSIS - GC PROFILING

Cannabis: Ancient Medicine, Modern Marvel Jessica Baker, LAc, RH (AHG)

Cannabis Testing Laboratory Solutions

Arthritis & Migraine Sufferer Gets 100% Same Day Relief...After Trying Everything (Including Turmeric)

Loveland Molecular Laboratories

Loveland Molecular Laboratories

GC/MS BATCH NUMBER: N10101

CERTIFICATE OF ANALYSIS - GC PROFILING

Medical Cannabis Terpene Measurement using the SRI 8610C FID GC

The Determination of CBD and General Cannabinoid Content in Hemp Oils Using HPLC with UV Detection

GC/MS BATCH NUMBER: G50106

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

Detection of cannabinoids in Cannabis sativa plants

Susan Audino, PhD S.A. Audino & Associates, LLC

Improving The Quality And Efficiency Of Terpene Extraction From Cannabis Plant

Cannabis: Ancient Medicine, Modern Marvel Jessica Baker, LAc, RH (AHG)

Qualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection

Extraction News Notes Blog

Not All Hemp is Created Equal

Not All Hemp is Created Equal

Quality Assessments for an Organically-Complex Drug - Part 1 Background and the Chemometrics Role

Cannabis and the Endocannabinoid System

13Essentials Cannabis Trial Oct 2016 Jan Cannabis Trial Michigan, USA October January 2017

GC/MS BATCH NUMBER: F50101

Extraction, Isolation and Analysis of Cannabis Extract and Preparation

GC/MS BATCH NUMBER: P50102

Potency, Terpenes and Pesticides Analysis Using High Resolution LC-MS/MS: Results and Comparison to Alternative Analytical Methodologies

Analysis of Cannabinoids in Cannabis by UHPLC Using PDA Detection

SAMPLE IDENTIFICATION ANALYSIS. Date : January 19, 2017

INFUSED II LABORATORY REPORT

GC/MS BATCH NUMBER: G40106

Fast and Easy Cannabis Potency Testing Using an Entry Level Agilent 1260 Infinity LC

IMPLEMENTATION-READY. CANNABIS TESTING Flowers, Extracts, Edibles, and Concentrates

GC/MS BATCH NUMBER: C80101


ABTRACT. Key words: solvent extraction, XAD-2 resin, free and glycosidically bound volatile compound, kaffir lime leaves

Cannabis History. ! Central Asia origins. ! Oldest recorded use: 2700BCE in Northern China. ! Ayurvedic use

ACS. Quality, Integrity, Safety. Our logo says it all

Determining Terpene Profiles of Cannabis Strains Using GC and GCxGC with High Performance TOFMS

GC/MS BATCH NUMBER: H20106

Medical Cannabis Then and Now. Jeffrey Skell, PhD

GC/MS BATCH NUMBER: G30103

Development of the Industrial Chain for the Production of Cannabigerol (CBG): from Plant to Pure Compound

Improved Gas Chromatographic Quantification of Acidic and Neutral Cannabinoids

SRI Model 420 Low Cost ( $ ) Gas Chromatograph for Cannabis Potency Testing June 2016

(B) A testing laboratory shall analyze a sample of at least one half of one percent of the

Flower Menu $15/gram $15 / 1 Gram Pre-roll $50 / 3.5 Grams $95 / 7 Grams $175 / 14 Grams $340 / 28 Grams Select Flower $13/Gram** / $45/3.

LC-MS/MS Solutions for Comprehensive Cannabis Analysis

SUPER SNOUTS CBD150 & CBD300 OIL FOR DOGS & CATS

GC/MS BATCH NUMBER: F90100

Responsibility through testing THE HANDBOOK. Understanding Your Laboratory

GC/MS BATCH NUMBER: R30102

Analysis of Cannabinoids in Hemp Seed Oils by HPLC Using PDA Detection

Analysis of Cannabinoids in Hemp Seed Oils by HPLC Using PDA Detection

Development of gas and liquid chromatographic methods for the separation and quantification of 11 cannabinoids

Cannabis for RDNs (Who Don t Know their CBD from their THC!)

PAST, PRESENT AND FUTURE OF MEDICAL CANNABIS

Transcription:

1 of 8 Dear Valued Colleague, Thank you for selecting C4 Laboratories. Our goal at C4 is to provide reliable data that is interpreted within the appropriate physiological context, to ultimately empower patients to use cannabis medicine more effectively. The data within this report are the result of various analytical methods that have been developed by the team of scientists at C4 Laboratories. For the characterization and quanti cation of 21 terpene compounds and residual solvents we use Head-Space Gas Chromatography with Flame Ionization Detection (HS-GC-FID). Additionally, Ultra High Performance Liquid Chromatography (UHPLC) is used for the characterization and quanti cation of the 10 major phytocannabinoids found in cannabis. All data are collected in concert with proper quality assurance/quality control measures (QA/QC), including the use of intermittent analytical blanks, sample spikes, and commercial standards. As an additional measure of quality control, we provide a historical reference (when available) to analytical results from an equivalent strain of cannabis/cannabis product to draw comparison. We understand that within an individual strain that results may vary as a result of variances in sample homogeniety, analytical methodology, crop conditions, genetic drift, and/or gene ow during hybridization. However, such a comparison can provide valuable insight into sample integrity and/or the phenotypic identity of the analyzed sample. Additionally, we have interpreted all data within the physiological context provided to us by the growing body of peerreviewed scienti c research studies. Key factors to consider when determining how to most appropriately use a particular strain of cannabis include, but are not limited to, an evaluation of the possible cannabinoid/terpene synergies and an analysis of the various cannabinoid ratios, particular the CBD-A/THC-A, CBD/THC and CBG/CBN ratios. Using the scienti c interpretations provided within this report, consult a physician prior to adopting a medical cannabis regiment for the treatment of speci c medical conditions. It is important to note that when analyzing cannabis there can exist natural variablity of cannabinoid and terpene concentrations within individual plants. Cannabinoid concentrations in cannabis ower have been found to increase distally with respect to the root mass. As such, the analysis of multiple samples from any plant of interest is recommended. Thank you again for your con dence in C4 Laboratories. We strive to be an authority on cannabis education, targeted therapies and patient protection. Also, as a research laboratory, we hope to discover novel cannabis constituents through our efforts with academic research programs in the C4 Cannabinomics Collaborative. For more information about how you can collaborate with our research team please visit our website at www.c4lab.com.

2 of 8 Cannabinoids Safety 71.986% 2.103% Not Tested Pass Pass Total THC Total CBD Microbials Foreign Matter Solvents Terpenes Pine -Pinene Flowers Geraniol Turpentine Terpinolene Cinnamon -Caryophyllene Hops -Myrcene

3 of 8 71.986% 2.103% Total THC 34.2 THC : Total CBD 1.0 CBD Cannabinoids Pass Foreign Matter Analyte LOQ Mass Mass Std. Dev. % % mg/g THCa 0.010 78.002 780.02 Δ9-THC 0.010 3.578 35.78 CBD 0.010 ND ND CBDa 0.010 2.398 23.98 CBC 0.010 ND ND CBG 0.010 ND ND CBN 0.010 ND ND THCV 0.010 ND ND Δ8-THC 0.010 ND ND CBDV 0.010 ND ND Total 83.978 839.78 Total THC = THCa * 0.877 + d9-thc Total CBD = CBDa * 0.877 + CBD LOQ = Limit of Quantitation; NR = Not Reported; Unless otherwise stated all quality control samples performed within speci cations established by the Laboratory.

4 of 8 Terpenes Pine Flowers Turpentine Cinnamon Hops Analyte LOQ Mass Mass % % mg/g -Pinene 0.001 0.030 0.30 Geraniol 0.001 0.024 0.24 Terpinolene 0.001 0.019 0.19 -Pinene 0.001 0.017 0.17 -Caryophyllene 0.001 0.006 0.06 -Myrcene 0.001 0.005 0.05 Ocimene 0.001 0.003 0.03 (-)- -Bisabolol 0.001 0.003 0.03 p-cymene 0.001 0.003 0.03 -Terpinene 0.001 0.002 0.02 Camphene 0.001 0.002 0.02 -Terpinene 0.001 0.002 0.02 -Humulene 0.001 ND ND Caryophyllene Oxide 0.001 ND ND -3-Carene 0.001 ND ND -Limonene 0.001 ND ND Eucalyptol 0.001 ND ND Guaiol 0.001 ND ND Linalool 0.001 ND ND Nerolidol 0.001 ND ND (-)-Isopulegol 0.001 ND ND 0.116% Total Terpenes LOQ = Limit of Quantitation; NR = Not Reported; Unless otherwise stated all quality control samples performed within speci cations established by the Laboratory.

5 of 8 Residual Solvents Pass Analyte Mass Status PPM Acetone 4 Pass Acetonitrile ND Pass Chloroform ND Pass Ethanol ND Pass Heptane ND Pass Hexanes ND Pass Isobutane ND Pass Isopropanol ND Pass Methanol ND Pass n-butane ND Pass Toluene ND Pass LOQ = Limit of Quantitation (1 ppm); ND = Not Detected; Unless otherwise stated all quality control samples performed within speci cations established by the Laboratory.

6 of 8