Three-dimensional measurement of enamel loss caused by bonding and debonding of orthodontic brackets. VAN WAES, H, MATTER, T, KREJCI, Ivo.

Similar documents
A Comparative Study between Bond Strength of Rebonded and Recycled Orthodontic Brackets

Enamel surface roughness following debonding using two resin grinding methods

Post Graduate Student, Dept. of Orthodontics, KD Dental College and Hospital, Mathura, UP 2

Orthodontic In Vivo Bond Strength: Comparison with In Vitro Results

Bonding to molars the effect of etch time (an in vitro study)

Bonding characteristics of a self-etching primer and precoated brackets: an in vitro study

COMPARISON OF FINISHING AND POLISHING SYSTEMS FOR RESIDUAL RESIN REMOVAL AFTER DEBONDING

Various composite resins are used in orthodontic

A scanning electron microscopy comparison of enamel polishing methods after air-rotor stripping

The Effects of the Acid Etch and Direct Bonding Technique in Orthodontics on Enamel Surface Topography

Immediate versus Delayed Force Application after Orthodontic Bonding; An In Vitro Study

The Effect of Different Bracket Base Cleaning Method on Shear Bond Strength of Rebonded Brackets

ORIGINAL RESEARCH. Sandhya CA Shyam Lohakare, Pushpa Vinay Hazarey ABSTRACT

Comparison of Shear Bond Strength of Metal Brackets Bonded to Porcelain Surface using Different Surface Conditioning Methods: An in vitro Study

SCIENTIFIC. Effects of various acids on the buccal surface of human permanent teeth: a study using scanning electron microscopy*

How to place a lower bonded retainer

Prophylaxis-based dental treatment: cavity prophylaxis using enamel-protective bracket attachment

Thermal Changes in the Pulp Chamber during Different Adhesive Clean-up Procedures

An In-Vivo Comparison Of The Efficacy Between Direct And Indirect Bonding Methods

The effectiveness of paint remover to resin adhesive residue on base mesh of metal bracket

Stereomicroscope Analysis of Enamel Surface after Orthodontic Bracket Debonding

Various whitening systems are currently being

BOCL-01: Bonding Materials Checklist

Office reconditioning of stainless steel orthodontic attachments

Interproximal Enamel Reduction in Orthodontic Treatment: A Review

Anisotropy of Tensile Strengths of Bovine Dentin Regarding Dentinal Tubule Orientation and Location

Assessment of the Confidence of the Adhesive Remnant Index Score With Different Methods

Effect of Self-etchant ph on Shear Bond Strength of Orthodontic Brackets: An in vitro Study

Evaluation of Shear Bond Strength Orthodontic Bracket and Adhesive Remaining Materials on the Enamel Surface Using ARI (Adhesive Remnant Index)

COMPARISON BETWEEN MOLAR BANDS, BONDABLE TUBES AND BONDABLE TUBES WITH FLOWABLE COMPOSITE

Effect of simulated debracketing on enamel damage

COMPARISON OF SHEAR BOND STRENGTH OF NEW AND RECYCLED BRACKETS WITH DIFFERENT MESH DESIGNS

Incognito Appliance System Bonding Protocols Step-by-Step Procedures

Pits and fissures: Relative space contribution in fissures from sealants, prophylaxis pastes and organic remnants

Clinical Guideline. for full contour zirconia restorations produced chairside with CEREC Zirconia (milling process).

Scanning Electron Microscopy Evaluation of the Bonding Mechanism of a Self-etching Primer on Enamel

Shadeguides Ceramic Veneers: Tooth Preparation for Enamel Preservation

Glass ionomer cements in complex oral rehabilitations. A case report.

The effect of different force magnitudes for placement of orthodontic brackets on shear bond strength, in three adhesive systems

Efficient Bonding Protocol for the Insignia Custom Bracket System

1. Rotosonic burs have 6 sides with non-cutting edge and will not injure soft and hard tissue.

Original Research. Shear bond strength of new self etching primer (RSEP) Sorake A et al

Clinical report. Drs Paul and Alexandre MIARA and F. CONNOLLY COMPOSITE POSTERIOR FILLINGS. How to control. layering? 8 - Dentoscope n 124

A Comparison of Bond Strength Between Directand Indirect-bonding Methods

Enamel Surface Roughness after Debonding of Orthodontic. Brackets and Various Clean-Up Techniques

Clinical Management of Tooth Size Discrepanciesjerd_

Corresponding Author:Dr.Sneha Vaidya 3

ADHESIVE RECONSTRUCTION IN HELP OF THE ORTHODONTIC TREATMENT

Shear Bond Strength of Acidic Primer, Light-Cure Glass Ionomer, Light-Cure and Self Cure Composite Adhesive Systems - An In Vitro Study

Early Shear Bond Strength of a One-step Self-adhesive on Orthodontic Brackets

No Prep And Minimal Prep Veneers

Restorative Resin Cement for Bonding and Masking Tetracycline and Dark Stained Teeth for All Veneers

Simple. Esthetic. Efficient. Available exclusively from:

Torque correction is one of the most difficult

For the Perfect Class V and All Cervical Area Gingival Margins when Placing Direct Composites, Create an Injection Molding Matrix

Etching with EDTA- An in vitro study

Chairside Reference Guide

Lower Anterior Crowding Correction by a Convenient Lingual Methodjerd_

Patient demand for esthetic dentistry

Influence of saliva contamination on the shear bond strength of adhesives on enamel

A Step-by-Step Approach to

Recommended IDB Protocol

DH220 Dental Materials

IMPLANT - Abutment made of titanium - Crown - Lithium disilicate - Retentive abutment shape - Posterior tooth - SpeedCEM Plus

Dentistry at Willow Mill Veterinary Hospital. Importance of Good Oral Hygiene. Steps for a Healthy Mouth

Bond strength assessment of metal brackets bonded to porcelain fused to metal surface using different surface conditioning method

Hex-Lock Abutment System. Restorative Manual

Metal-Free Restorations PROCEDURES FOR POSTERIOR DIRECT & SEMI-DIRECT COMPOSITE RESTORATIONS D I D I E R D I E T S C H I. For.

3D Printing Dentures. Dental Application Print Guide

6/1/15. Bonding Ceramic Veneers in What we did? What we do? Using Evidence-Based Dentistry XXXX ?????

illustrated technique guide

of the treated areas by means of a No. 3 explorer. The smoothness of the tooth-amalgam interface was then examined on each specimen by

Glass Ionomer Cement as an Orthodontic Bonding Agent

Lec. 3-4 Dr. Saif Alarab Clinical Technique for Class I Amalgam Restorations The outline form

GUIDELINES FOR PROCESSING CELTRA DUO

A Formula for Success. Lava All Zirconia. The flexibility you need. 3M All Rights Reserved.

Acknowledgments Introduction p. 1 Objectives p. 1 Goals p. 2 History of Dental Materials p. 3 The Oral Environment p. 4 Characteristics of the Ideal

Enamel Roughness Changes after Removal of Orthodontic Adhesive

Clinpro Glycine Prophy Powder

The Use of Glass-fibers Ribbon and Composite for Prosthetic Restoration of Missing Primary Teeth-Laboratory and Clinical Research

The effect of orthodontic bracket pad shape on shear bond strength, an in vitro study on human enamel

The acid-etch technique has been widely used in

TOOTH - Crown - Oxide ceramics - Retentive preparation - Super- and equigingival - Visible margin - SpeedCEM Plus

IMPLANT - Abutment made of titanium - Crown - Metal - Retentive abutment shape - Posterior tooth - SpeedCEM Plus

A Method for Stabilizing a Lingual Fixed Retainer in Place Prior to Bonding

CHAPTER THREE: INDUSTRY OVERVIEW... 6 STRUCTURE AND HISTORY OF THE DENTAL INDUSTRY... 6 STRUCTURE AND HISTORY (CONTINUED)... 8

Pits and fissures: etch resistance in prismless enamel walls

Perfect provisional restorations

TOOTH - Crown - Lithium disilicate - Retentive preparation - Super- and equigingival - Visible margin - SpeedCEM Plus

A lasting connection: Esthetic implantborne single-tooth restorations. Part 1

Adhesive Thickness Effects on the Bond Strength of a Light- Cured Resin-Modified Glass Ionomer Cement

Flowable Composite for Orthodontic Bracket Bonding (in vitro study)

Shear bond strength of a new polycarbonate bracketan in vitro study with 14 adhesives

Contactless Dentistry. Cleans, Cuts, Prepares - Gently

CURVES. Anatomically Adaptable IPR strips. Brochure Instructions for use Processing instructions

Filtek LS. Low Shrink Posterior Restorative System. Techniques and Results. Clinical Cases

The influence of accelerating the setting rate by ultrasound or heat on the bond strength of glass ionomers used as orthodontic bracket cements

DentaSonic. Safe, Smart, Smooth, Time Saving, and Comfortable Proximal Tool System. orthodontics/aligner restaurative finishing prophylaxis

Monobond Plus is the universal primer for the conditioning of all types of restoration surfaces

Transcription:

Article Three-dimensional measurement of enamel loss caused by bonding and debonding of orthodontic brackets VAN WAES, H, MATTER, T, KREJCI, Ivo Abstract A mechanical computerized three-dimensional scanner with a resolution of 1 micron was used to assess loss of enamel caused by orthodontic bonding and debonding. A total of 2646 measurements was performed on six human premolars. The results showed an average loss of enamel of 7.4 microns. The range was between 1 and 52 microns, which may account for discrepancies with earlier studies that measured only a few points per tooth surface. Reference VAN WAES, H, MATTER, T, KREJCI, Ivo. Three-dimensional measurement of enamel loss caused by bonding and debonding of orthodontic brackets. American Journal of Orthodontics and Dentofacial Orthopedics, 1997, vol. 112, no. 6, p. 666-669 PMID : 9423699 Available at: http://archive-ouverte.unige.ch/unige:81110 Disclaimer: layout of this document may differ from the published version.

Three-dimensional measurement of enamel loss caused by bonding and debonding of orthodontic brackets Hubertus van Waes, DDS, a Thomas Matter, DDS, b and Ivo Krejci, DDS, PhD c Zurich, Switzerland A mechanical computerized three-dimensional scanner with a resolution of 1 ixm was used to assess loss of enamel caused by orthodontic bonding and debonding. A total of 2646 measurements was performed on six human premolars. The results showed an average loss of enamel of 7.4 ixm. The range was between 1 and 52 Fm, which may account for discrepancies with earlier studies that measured only a few points per tooth surface. (Am J Orthod Dentofac Orthop 1997;112:666-9.) Ever since the introduction of the acidetch technique 1 and its use for bonding of orthodontic brackets, there has been discussion among orthodontists regarding the amount of enamel lost as a result of bonding and subsequent debonding. Damage to the enamel can be attributed to tooth cleaning with abrasives before etching, acid-etching, enamel fractures caused by forcibly removing brackets, or mechanical removal of remaining composite with rotary instruments, a'3 Remaining composite can be removed from the enamel surface by hand instruments or rotating abrasive tools. Factors such as the time needed for complete removal and potential damage to the enamel are essential to the clinician. The effect of different instruments on the surface of tooth enamel has been the subject of many studies and is therefore well known. 2,4-7 There are, however, few publications concerned with quantification of enamel loss. Zachrisson and Artun 5 concluded from the postoperative presence of perikymata, that the amount of enamel lost was minimal. This conclusion was refuted by Brown and Way, s who could show that even with enamel loss as high as 50 jxm, perikymata could still be observed. Quantitative measurements were performed either by judging the distance between an intraenamel implant and the enamel surface before and after bonding and debonding with a miniaturized boley gaug, 8 or by optical profilometric techniques, a,9 Both From the University of Zurich. ~Director of Pediatric Dentistry Program. bclinical instructor, Clinic for Orthodontics and Pediatric Dentistry, Center for Dental and Oral Medicine. CAssociate Professor, Clinic for Preventive Dentistry, Periodontology and Cariology, Center for Dental and Oral Medicine. Reprint requests to: Dr. H. van Waes, Clinic for Orthodontics and Pediatric Dentistry, Center for Dental and Oral Medicine, University of Zfirich, Plattenstrasse li, 8028 Z(irich, Switzerland. Copyright 1997 by the American Association of Orthodontists. 0889-5406/97/$5,00 + 0 8/1/'78428 techniques allow only a small number of measurements per tooth surface and it must therefore be assumed that local enamel defects as produced by rotary instruments or residual composite must heavily influence the results. To reduce the influence of artefacts on the final results, as many measurements as possible must be performed on each tooth surface, a demand that is not easily fulfilled with manual measurements. In the field of operative dentistry, methods to quantify the loss of substance caused by abrasion of restorations or antagonist teeth are common. Computer-assisted techniques allow measurements of many points of a tooth surface and volumetric calculation of the total loss of substance. The current study was performed to calculate the loss of enamel caused by orthodontic bonding and debonding in vitro by using a method described earlier by Krejci et al? MATERIAL AND METHODS Subjects for the measurements were six human premolars, which were extracted for orthodontic reasons and were stored in a 0.1% solution of thymol before entering the study. Immediately before bonding, all teeth were cleaned for 30 seconds with a pumice slurry on a rotating brush, and the roots were cut off with a diamond disk. The crowns were then mounted on a specially designed carrier with a light-curing compomer (Dyraet, De Trey Dentsply). The buccal surface of the crowns was oriented parallel to the surface of the carrier. The carrier contains reference points for calibration and for calculation of the system error and was used to allow for standardized mounting of all samples in the measuring device. All samples were scanned in a mechanical computerized three-dimensional scanner (3DS). This scanner has a resolution of 1 ~m, a reproducibility better than 1 txm a and allows scanning of an area of 10 10 ram. Surfaces not perpendicular to the scanning instrument cannot be measured precisely. To reduce the possibility of error, a 666

American Journal of Orthodontics and Dentofacial Orthopedics van Waes, Matter, and Krejci 667 Volume 112, No. 6 Table h Distribution of the scores for enamel loss in percent of all measurements Range of enamel l [ I J loss Tooth I Tooth 2 Tooth 3 Tooth 4 Tooth 5 Tooth 6 Average % % % 00-05 77 05-10 15 10-15 4 15-20 2 20-25 2 25-30 30-35 35-40 40-45 45-50 >50 20 40 42 35 32 40 29 20 16 11 6 1 3 1.5 1 2 0.5 29 11 36.5 43 38 33.8 24 29 20.3 4 11 5.8 4 1.9 2 0.75 2 0.33 1 0.16 1 0.16 0.5 0.08 0.5 0.08 smaller area (3 3 mm) was scanned. This resulted in 441 measurements per tooth and a total of 2646 measurements (Fig. 1). Immediately after the initial scanning, all samples were etched with 37% orthophosphoric acid (Ultra- Etch, Ultradent Products, Inc.) for 60 seconds, then rinsed with a water/air spray for 20 seconds, and air dried. A minibracket (Mini-Diamont/ORMCO) was then bonded with a chemically curing composite (Concise, 3M) in such a position that a small part of the scanned area was not covered by the bracket base. This position was chosen to make it possible to detect differences in enamel loss between covered and uncovered parts of the enamel surface. Excess composite was removed before complete curing with a scaler, according to a common clinical procedure. After curing of the composite, all samples were stored in water at room temperature for 48 hours before brackets were removed by gently squeezing the bracket wings with pliers. The subsequent removal of the remaining composite on the tooth surface was performed under clinic-like conditions with a tungsten-carbide bur (Komet no. 1171, Gebr. Brasseler) at a speed of 20000 rpm, without water cooling. The removal of the composite was considered complete when the tooth surface seemed smooth and free of composite to the naked eye, under the light of the operatory lamp. This procedure is widely used by orthodontists. Its efficacy and qualitative effect on the enamel surface is well documented. 2,4-7 We decided to waive the usual clinical routine of the enamel surface polishing, because of difficulties in standardizing pressure and duration of this procedure in the clinical situation. After debonding, all samples were again scanned. The difference between initial and final scores was determined by computer calculation. This difference indicated the total loss of enamel substance. Because the measurement of lost enamel was the purpose of this study, the computer has been programmed to only record the "loss of substance" and not "gain of substance"(e.g., residual compos- Fig. 1. Schematic drawing of three-dimensional scanner. ite), so that remaining composite would not influence the average of enamel loss. After the second scanning, the samples were dried and gold-coated for qualitative analysis of the enamel surface in the scanning electron microscope (SEM), as described in an earlier publication. 11 RESULTS Measurement of enamel loss was successful on all six samples, resulting in a total number of 2646 measurements. In all samples, a loss of enamel could be measured. This enamel loss was unevenly distributed over the scanned area (Table I and Fig. 2). The minimal enamel loss measured was 1 Ixm, whereas the recorded maximum loss was 52 Ixm. For each sample, a table of distribution of the scores was printed. The average loss of enamel for each sample was between 3.9 and 11.2 ixm, the average for all samples was 7.4 }xm (Table II). The volume of the lost substance was calculated at between 0.02 and 0.05 mm 3. Negative scores for the loss of substance

668 van Waes, Matter, and Krejci American Journal of Orthodontics and Dentofacial Orthopedics December 1997 % of samples Distribution of average enamel loss scores 40 ~- 35 30 25 20 15 10 Enamel- loss in pm o 00435 o5-1o 10-15 15-2o 20-25 25-30 30-35 35-40 40-45 45-50 >50 Fig. 2. Bar graph of distribution of scores for average enamel loss in percentage as listed in Table I. Table II. Minimal, maximal, and average scores of enamel loss (in &m), volume of lost enamel Tooth 1 Tooth 2 Tooth 3 Tooth 4 Tooth 5 Tooth 6 Average Minimum 1 1 1 1 1 1 Maximum 23 31 27 20 18 52 Aver ag~ 319 9.5 6.9 5~ 9 7~ ~ ~ i 12 714 Volume 0.004 0.04 0.03 0.02 0.03 0.05 lost mm 3 Fig. 3. Scanning electron microscopic view of surface of sample after removal of residual composite. Note grooves and scratches caused by tungsten-carbide bur. were not recorded by scanning, but the qualitative rating in the SEM showed very little remaining composite on the enamel surface of each sample. On all teeth, some scratches and grooves could be observed (Fig. 3). No differences could be observed between the areas covered by the brackets and those that remained uncovered. DISCUSSION The results of the current study clearly show that the loss of enamel because of orthodontic bonding and debonding is not evenly distributed over the tooth surface. This finding questions the results of earlier studies that measured only a few points on the tooth surface?,s'9 The findings for enamel loss in our study are well under the results found in the literature. More than 90% of all the scores for enamel loss were within a range of 0 to 20 txm. These results might be influenced by remaining composite on the tooth surface. The SEM analysis,

American Journal of Orthodontics and Dentofacial Orthopedics van Waes, Matter, and Krejci 669 Volume i12, No. 6 however, showed only traces of composite on the surface, mainly in preoperatively present grooves. This is in agreement with the findings of earlier studies. 6 Clinically, these results would be interpreted as complete removal of composite. In the SEM, some scratches and grooves were observed on the surface of all samples. These grooves were interpreted as an explanation for the extreme high scores found in the scanning analysis. Loss of enamel because of tooth cleaning before bonding and after debonding of brackets was not recorded. Brown and Way s found enamel loss of 26 Ixm as a result of prophylaxis. The current study shows that the three-dimensional scanner can successfully be used to determine the effect of orthodontic techniques on enamel wear. The results are precise and reproducible, m On the basis of the results of this in vitro observation, one can conclude that residual composite on the tooth surface can be removed with minimal enamel damage, by careful use of a ttmgsten-carbide bur. It is possible that these results have only limited clinical importance, because the removal of residual composite is clinically performed under less favorable conditions. Brown and Way 8 stated that there was less loss of enamel in clinic than in vitro, because the (destructive) removal of composite is more extensive in vitro due to the better visibility of composite remnants. CONCLUSIONS 1. Three-dimensional scanners can successfully be used to measure enamel loss due to orthodontic procedures. 2. The average loss of enamel due to the removal of composite remnants after debonding with a tungsten-carbide bur is 7.4 txm. REFERENCES 1. Buonocore MG. A simple method of increasing the adhesion of acrylic filling materials to enamel surfaces. J Dent Res 1955;34:849-53. 2. Pus MD, Way De. Enamel loss due to orthodontic bonding with filled and unfilled resins using various clean-up techniques. Am J Orthod Dentofac Orthop I980;77: 269-83. 3. Diedrich P. Enamel alterations from bracket bonding and debonding: a study with the scanning electron microscope. Am J Orthod Dentofac Orthop 1981; 79:500-22. 4. Retief DH, Dews MS. Finishing of enamel surfaces after debonding of orthodontic attachments. Angle Orthod i979;49:1-10. 5. Zachrisson BU, Artun J. Enamel surface appearance after various debonding techniques. Am J Orthod Dentofac Orthup 1979;75:121-37. 6. Hong YH, Lew KKK. Quantitative and qualitative assessment of enamel surface following five composite removal methods after bracket debonding. Eur J Orthod 1995;17:121-8. 7. Campbell PM. Enamel surfaces after orthodontic bracket debonding. Angle Orthod 1995;65:103-10. 8. Brown CRL, Way DE. Enamel loss during orthodontic bonding and subsequent loss during removal of filled and unfilled adhesives. Am J Orthod Dentofac Orthop 1978;74:663-70. 9. KrelI KV, Courey JM, Bishara SE. Orthodontic bracket removal using conventional and ultrasonic debonding techniques, enamel loss and time requirements. Am J Orthod Dentofac Orthop 1993;103:258-66. 10. Krejci I, Reich Th, Bucher W, Lutz F. Eine neue Methode zur dreidimensionalen Verschleissmessuug. Schweiz Monatsschr Zahnmed 1994;104:160-9. 11. Van Waes H, Matter Th. Art und Zeitpunkt der Oberschussentfernung beim Kleben orthodontischer Brackets. Informationen Orthod Kieferorthop 1993;25: 173-7.