Liquid Chromatograph Mass Spectrometer LCMS-8050 C146-E232A

Similar documents
Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188E

Liquid Chromatograph Mass Spectrometer LCMS-8060 C146-E286

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

Determination of Amantadine Residues in Chicken by LCMS-8040

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

Vitamin D3 and related compounds by ESI and APCI

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids

C146-E121A LCMS Shimadzu Liquid Chromatograph Mass Spectrometer

Designer Cannabinoids

Agilent 6490 Triple Quadrupole LC/MS System with ifunnel Technology. Ultra sensitive quantitative performance

High Throughput simultaneous analysis of 39 amino acids in various foods without derivatization using LC-MS/MS

Highly sensitive simultaneous quantitative analysis of estrone and equilin from plasma using LC/MS/MS

Separation and Quantitation of Oxysterol Compounds Using LC-MS/MS. Liquid Chromatography Mass Spectrometry SSI-LCMS-082

Join the mass movement towards mass spectrometry

All stocks and calibration levels were prepared in water: methanol (50:50) v/v to cover range of all steroid concentrations (refer Table 1).

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS

Rapid Screening and Quantitation of Pesticide Residues in Cannabis by Modified QuEChERS and LC-MS-MS

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification

Latest Innovations in LC/MS/MS from Waters for Metabolism and Bioanalytical Applications

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

The New 6495 Triple Quadrupole LC/MS

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS

More structural information with MS n

Agilent s LC/MS Portfolio and Applications Examples

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer

Introduction to LC/MS/MS

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

LC-MS/MS Method for the Determination of Tenofovir from Plasma

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate Mass AxION 2 TOF Mass Spectrometer

Edgar Naegele. Abstract

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Fully Automated Online Sample Preparation AND Quantification of Amiodarone from Whole Blood using CLAM-LC-MS/MS

Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF

Modernizing the Forensic Lab with LC-MS/MS Technology

Sample Concentration and Analysis of Human Hormones in Drinking Water

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS

Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution

A NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS.

LCMS-8030 Application Report. Steroids: Testosterone, Progesterone, Estradiol, Ethinylestradiol

Overview. Introduction. Experimental. Cliquid Software for Routine LC/MS/MS Analysis

Cannabis Testing Laboratory Solutions

Comparison of a UPLC Method across Multiple UHPLC Systems

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1

[ APPLICATION NOTE ] High Sensitivity Intact Monoclonal Antibody (mab) HRMS Quantification APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

Characterization of products formed by forced degradation of Etodoalc using LC/MS/MS

PTM Discovery Method for Automated Identification and Sequencing of Phosphopeptides Using the Q TRAP LC/MS/MS System

Agilent 7700x ICP-MS

Identification of Steroids in Water by Ion Trap LC/MS/MS Application

Fully automated sensitive determination of immunosuppressant drugs in whole blood, using high quality internal standardization

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

Method Development for the Analysis of Endogenous Steroids Using Convergence Chromatography with Mass Spectrometric Detection

Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

Meeting Challenging Requirements for the Quantitation of Regulated Growth Promoters Dexamethasone and Betamethasone in Liver and Milk

Oxysterol, Secosterols, and Cholesterol Intermediates Separation and Quantitation Using Triple Quadrupole Mass Spectrometry

Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE. SLE+ Prior to LC/MS-MS Analysis

Agilent 6495 Triple Quadrupole LC/MS System

Phospholipid characterization by a TQ-MS data based identification scheme

Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites

2D-LC as an Automated Desalting Tool for MSD Analysis

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids

Dienes Derivatization MaxSpec Kit

LCMS Vitamin D3 Method development

Exploring Changes in Primary Metabolites in Alzheimer s Disease using Targeted LC-MS/MS

Analysis and Quantitation of Cocaine on Currency Using GC-MS/MS. No. GCMS No. SSI-GCMS-1501

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

Polymer Additive Analysis by EI and APCI

Quantitative Analysis of Carbohydrates and Artificial Sweeteners in Food Samples Using GFC- MS with APCI Interface and Post-column Reagent Addition

Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa

Measuring Lipid Composition LC-MS/MS

Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System

Evaluation of UHPLC System Performance Under High Throughput Conditions. William Hedgepeth, Masatoshi Takahashi, Shimadzu Scientific Instruments

Jose Castro-Perez, Henry Shion, Kate Yu, John Shockcor, Emma Marsden-Edwards, Jeff Goshawk Waters Corporation, Milford, MA, U.S. and Manchester, UK

Using Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Transcription:

Liquid Chromatograph Mass Spectrometer LCMS-85 C146-E232A

Speed and

Sensitivity Beyond Comparison Continuing the evolution of Shimadzu's UF technology, Shimadzu introduces the LCMS-85 triple quadrupole mass spectrometer, offering unparalleled measurement speeds and high-sensitivity performance. High-sensitivity quantitation delivered at high speed Multi-component analysis performed more rapidly Simultaneous qualitative and quantitative analyses The high performance of the LCMS-85 defies expectations, redefining high-sensitivity, high-speed analysis.

Experience a New Realm of High-Sensitivity & High-Speed Performance UFsensitivity Combining Speed and High Sensitivity UFswitching High-Sensitivity & High-Speed Positive/Negative Ionization Switching in 5 msec Just One Minute per Analysis A Case Study Using High-Speed Positive/Negative Ionization Switching When performing simultaneous positive/negative ion measurements of multiple components, the proper acquisition of sharp UHPLC peaks depends on rapid polarity switching. The LCMS-85 minimizes losses due to polarity switching and ensures the collection of sufficient data points for even the narrow peaks obtained with UHPLC, recording accurate peak shapes and allowing excellent reproducibility. Existing CYP Inhibition Method: 7 Minutes % Reduce to 1 minute Easily obtains over 2 points per peak with UHPLC. Achieves excellent reproducibility even at the lowest calibration level. Features a wider dynamic range than other available triple quads.. 1 min 2. 3. 4. 5. 6. 7 min Nexera with LCMS-85 Compound Polarity Legacy HPLC Method 7 min Dynamic range (nmol/l) Points/ peak %RSD.6 nmol/l (n=4) Nexera with LCMS-85 1 min Dynamic range (nmol/l) Points/ peak %RSD.6 nmol/l (n=4) % Resorufin 1 -Hydroxy Bufuralol.6-3.6-3 19 21 4.66 2.39.6-.6-21 24 4.3 1.82 (+/-)-4 -Hydroxy Mephenytoin.6-3 2 2.75.6-23 2.18..25.5.75 1 min Oxidized Nifedipine Hydroxy Tolbutamide.6-3.6-3 19 2 5.58 5.68.6-.6-23 23 5.7 2.96 4

UFscanning High-Sensitivity & High-Speed Scanning at 3, u/sec Simultaneous Quantitative and Qualitative Analysis Simultaneous High-Speed Screening of 12 Toxicological Drugs The LCMS-85 is capable of simultaneously obtaining both qualitative and quantitative information in a single analysis. Acquisition occurs so rapidly that MS/MS scans and MRM measurements can be performed concurrently while maintaining quantitative accuracy. MS/MS scans are usable and reliable because even at 3, u/sec, Shimadzu uses a.1 u scan step. % 11. Maintains a high-quality spectrum 3, u/sec 268 even at the world s fastest 3, u/sec scanning speed of 3, u/sec. 239 239 211 119 183 314 The 3, u/sec scanning speed 119 183 211 314 provides for more sampling points. 5 15 2 25 m/z 5 15 2 25 m/z Flunitrazepam 1 ng/ml 13 points %RSD (n=3) 2.45% 12. min 11. % Flunitrazepam 1 ng/ml 12. min 268 9 points %RSD (n=3) 8.75% MRM Triggered Product Ion Scanning of a Mixture of 12 Benzodiazepines (1 ng/ml each) UF-MRM High-Sensitivity & High-Speed MRM at 555 ch/sec Detect Target Compounds at Trace-Level Concentrations Simultaneous Analysis of 29 Pesticides for Water Quality Analysis The LCMS-85 is capable of simultaneously acquiring 555 MRM transitions per second while maintaining accuracy and precision. Sufficient data points can be collected for quantitation ions, reference ions, and internal standard ions even in chromatographic regions with unresolved peaks. The high sensitivity of the LCMS-85 allows for trace-level analysis, such as pesticides in drinking water, without the need for sample pre-concentration. This high sensitivity is maintained even when monitoring numerous MRM channels. % 1.5 2. 2.5 3. 3.5 min MRM Chromatogram of 29 Pesticides for Water Quality Analysis ( pg/ml each) LCMS-85 has achieved LOQs that fulfill the 1/ target value without sample pre-concentration. No Compound 1 Thiuram 2 Bentazone 3 Carbofuran 4 2,4-D 5 Triclopyr 6 Iprodione 7 Asulam 8 Bensulide 9 Mecoprop (MCPP) 1 Carbaryl (NAC) 11 Carpropamid 12 Fenthion (MPP) 13 MPP sulfoxide 14 MPP sulfone 15 MPP oxon LOQ pg/ml 2. 3.9 1.6 46.7 45.3 1.7 2.3 4.8 6.1 2.3 1.3 3.1 1.7 5.1 4.9 1/ of target pg/ml* 2 2 5 3 6 3 2 5 5 4 1 1 1 1 No 16 17 18 19 2 21 22 23 24 25 26 27 28 29 Compound MPP oxon sulfoxide MPP oxon sulfone Dymron Methomyl Probenazole Diuron (DCMU) Bensulfuron-methyl Tricyclazole Azoxystrobin Halosulfuron-methyl Flazasulfuron Thiodicarb Siduron Fipronil LOQ pg/ml 4.2 5.7.65 2.3 5.2.7 4.4 2.7 2.7.52.47 3.4.82 4.7 1/ of target pg/ml* 1 1 8 3 5 2 4 8 5 3 3 8 3 5 *Note: Official analytical methods require detection to 1/th of regulatory targets. 5

UFsensitivity High Sensitivity for Trace Quantitative Analysis Scientists who demand trace-level quantitation will benefit from a newly designed heated ESI probe and a new high-efficiency CID cell, the UFsweeper III. These technological improvements combined with Shimadzu s patented ion optics system deliver durable high-sensitivity performance. 6

UFscanning UFsensitivity UFswitching UF-MRM Heated ESI Probe Heating gas flow Nebulizer gas flow In order to improve desolvation efficiency, the newly developed heated ESI probe combines a high-temperature gas with the nebulizer spray, assisting in the desolvation of large droplets and facilitating ionization. This development allows for high-sensitivity analysis of a wide range of target compounds. * * % 289.5 > 97.1 Heating gas ON Signal intensity: 3 X improvement Heating gas OFF.5 1. 1.5 min *The transmission of heat to the LC line has been minimized by mounting the heaters in the bottom-most position. MRM Chromatogram of Testosterone Excellent Reproducibility Even at Attogram (ag) Levels Both sensitivity and reproducibility are essential when establishing low limits of quantitation. High-precision quantitative results obtained with the LCMS-85 in the analysis of Verapamil in blood plasma at levels between 5 ag and 5 pg are shown below. Excellent reproducibility with a % RSD of 2.77 % was obtained when analyzing just 5 ag of Verapamil. The LCMS-85 demonstrates optimal performance for quantitative analysis of even trace components of a complex matrix. 455.4 > 165. 5 ag in plasma Concentration actual ng/ml Calculated concentration ng/ml % RSD (n = 6) Accuracy (%) (n = 6) %.5.51 2.77.2.5.496 3.98 99.2.5.56 1.21 11.2.5 5..493 4.89 1.31 1.81 98.6 97.8.8.9 1. 1.1 1.2 min 5. 51.6.65 13.2 MRM Chromatogram of Verapamil Liquid Chromatograph Mass Spectrometer LCMS-85 7

UFswitching Polarity Switching Technology with No Compromise in Quality or Sensitivity Ultra-high speed positive/negative ionization switching technology [ UFswitching ] maintains constant quality and sensitivity with no loss of quantitative accuracy. Laboratories can now use a single method for both positive and negative ions, increasing sample throughput and saving method development time. 8

UFscanning UFsensitivity UFswitching UF-MRM Only 5 msec to Achieve Stable Quantitative Accuracy with Positive/Negative Ionization Switching The LCMS-85 uses unique high-voltage power supply technology to achieve an ultra-high-speed positive/negative ionization switching time of just 5 msec. The LCMS-85 is also the only instrument of its type to maintain ion intensity even when performing polarity switching at ultra-high speed, yielding consistent, reproducible data. Excellent quantitative results can be obtained from UHPLC peaks no more than 2-3 seconds wide, even when multiple components are eluted simultaneously. % Ion intensity is maintained even when performing polarity switching at ultra-high speed. 69.2 >195.2 (+) 138. >18.1 ( )..1.2 min %..1.2 min..1.2 min Positive Positive Negative Negative % Comparison of measurement using the ultra-fast polarity switching (5 msec) and individual measurement of positive and negative ions. Outstanding Throughput and Quantitative Accuracy Positive and negative ions measured separately Analysis Start Analysis End + - Analysis Time: 2 min Analysis Time: 2 min After completing analyses in positive ion mode, a second analysis begins in negative ion mode. Inadequate polarity switching + - + Switching Switching Switching Switching - Cycle time 1 2 3 4 5 Analysis Time: 2 min 6 Since the cycle time is longer, sufficient data points cannot be obtained for each peak. Loss of quantitative accuracy Ultra-fast polarity switching + - + - Cycle time 4 5 6 7 8 Analysis Time: 2 min A short cycle time enables acquisition of a sufficient number of data points for each peak. Maintains quantitative accuracy 1 2 3 9 1 11 Liquid Chromatograph Mass Spectrometer LCMS-85 9

UFscanning Simultaneous, Highly Reliable Quantitative and Qualitative Analysis Employing ultra-high-speed scan technology [ UFscanning ], the LCMS-85 maintains spectrum quality at any scan speed. Perform quantitative and qualitative analysis simultaneously with a high-speed scan rate of 3, u/sec. 1

UFscanning UFsensitivity UFswitching UF-MRM Maintain Sensitivity and Mass Accuracy Even at 3, u/sec 1. Inten. ( 1,,) 115.9 5, u/sec By controlling the voltage applied to the quadrupoles according to scan speed and m/z, the LCMS-85 achieves superior ion transmission at any scan speed. And because Shimadzu maintains data collection at.1 u intervals, high-quality mass spectra are obtained without loss of sensitivity or mass accuracy..5. 7.1 22.9 37.2 555.2 642.2 25 5 m/z Inten. ( 1,,) 1. 115.9 1, u/sec 1 u steps -2-1 True value +1 +2 m/z Top of peak is not defined resulting in a large variation in the m/z determination..5. 7. 642.2 22.9 37.2 555.3 25 5 m/z.5 u steps Inten. ( 1,,) -2-1 True value +1 +2 m/z 1. 115.9 3, u/sec.1 u steps -2-1 True value +1 +2 m/z Proper data collection rate allows accurate determination of m/z value..5. 7.1 642.1 22.7 37.2 555.2 25 5 m/z Variation in m/z Caused by Different Sampling Intervals for Spectral Data Bradykinin (MW 756.4) Product Ion Scan Spectrum Precursor Ion m/z 379.4 Efficient Qualitative Analysis Using Synchronized Survey Scan The Synchronized Survey Scan (SSS) function allows MRM acquisition to be combined with a variety of other scan modes. It is extremely useful for obtaining more detailed qualitative information on components detected during multi-analyte quantitative acquisition. One thousand events can be registered within a single method. It allows setting of optimum collision energies for each component in order to obtain only the required qualitative information. An Example Method for Performing an MRM-Triggered Product Ion Scan Liquid Chromatograph Mass Spectrometer LCMS-85 11

UF Technologies Combine Sensitivity and High Speed The LCMS-85 combines the following technologies to ensure highly sensitive, high-speed performance: [ UFsensitivity ] achieves high-sensitivity performance utilizing a new heated ESI probe and new UFsweeper III collision cell. [ UFswitching ] high-speed positive/negative ionization switching and high-speed MRM [ UF-MRM ] maintain data quality and sensitivity. [ UFscanning ] high-speed scan rate obtains high-quality mass spectra, even during high-speed analysis. Heated ESI Probe High-temperature gas supplements the nebulizer gas, improving desolvation efficiency. This facilitates the ionization of a wide range of compounds. Ionization Unit Designed without cables or tubes; utilize a one-touch lever to perform simple attachment and detachment of the unit. Ultrafast Response High-Voltage Power Supply for Polarity Switching DL (Desolvation Line) Qarray Patented Q-array ion guide is designed to effectively focus ions over a wide m/z range by overlapping multiple electric fields. 12

UFsweeper III Collision Cell ( 1,) UFsweeper II UFsweeper III A high-sensitivity, high-speed collision cell, the proprietary UFsweeper III accelerates ions out of the collision cell without loss of momentum. Achieving fast sweeping on successive scans, it offers twice the CID efficiency of UFsweeper II, maintains signal intensity, and suppresses crosstalk, even for high-speed or simultaneous multi-component analysis. 1.5 1..5 Reserpine 69.3 >195.(+) 2 times the CID efficiency 1. 2. 3. min 1. 2. 3. min UFscanning UF-MRM UFswitching UFsensitivity UF-MRM UFsweeper III high-speed ion transport technology minimizes ion loss even at a dwell time of.8 msec. High-speed MRM transitions up to 555 ch/sec accelerate laboratory throughput for simultaneous multi-component analyses. UF-Lens Combines two multi-pole RF ion guides to achieve efficient ion transport and high sensitivity. Quadrupole Rod A high-performance hyperbolic mass filter with a proven track record in LC/MS, it maintains high ion transmittance and high sensitivity, even at a high-speed scanning rate of 3, u/sec. Ultrafast Response Detector The ultrafast high-voltage power supply allows high-speed positive/negative ion mode switching of the detector voltage. Liquid Chromatograph Mass Spectrometer LCMS-85 13

Engineered for Robustness and Easy Operation/Maintenance Maintains High Sensitivity Even During Successive Demanding Analyses In addition to speed and sensitivity, Shimadzu designed the LCMS-85 for robustness to meet the most demanding laboratory requirements and most difficult matrices. The figure below plots the area results from consecutive analyses of a deproteinized blood plasma sample spiked with alprazolam. The LCMS-85 achieves excellent reproducibility with a 4.59 % RSD for the area results over the analyses. 4 1 4 3 5 pg/ml alprazolam in plasma m/z 39.5 > 281.15 Area % RSD = 4.59 % Area 2 ( 1 3 ) ( 1 3 ) ( 1 3 ) 1 5. 1 st injection 5. 5 th injection 5. th injection. 1. 1.1 1.2 1.3 1.4 min. 1. 1.1 1.2 1.3 1.4 min 2 3 4 5. 1. 1.1 1.2 1.3 1.4 min 6 7 8 9 Injection Easy System Maintenance Reduces Downtime As with Shimadzu s other triple quad systems, maintaining the LCMS-85 is simple. Replacing the desolvation line (DL) and ESI capillary is quick and easy. Additionally, the design allows users to replace the DL without breaking vacuum, providing greater uptime and usability. Steps for DL Replacement 1 2 3 DL (Desolvation Line) Steps for ESI Capillary Replacement 1 2 3 ESI Capillary 14

Newly Designed Ionization Unit Designed without cables or tubes, removing the new ionization unit is simple: release a one-touch lever to open the unit and lift it out. In addition, no tools are needed to detach the needles fitted in APCI and DUIS units, allowing for easy maintenance. ESI-85 ( standard ) APCI-85 ( optional ) DUIS-85 ( optional ) Liquid Chromatograph Mass Spectrometer LCMS-85 15

LabSolutions LCMS Ver. 5.6 LabSolutions LCMS is integrated workstation software used to control LCMS-83/84/85 models, as well as Shimadzu HPLC/UHPLC systems from a single user interface. Equipped with a variety of data processing features, the software allows the creation of quantitation methods for multi-component analysis, enabling anyone to perform quantitative analyses with ease. Automatic Calculation of Dwell Time The optimum dwell time is calculated automatically from the number of overlapping MRM channels and maximum loop time, thereby obtaining the necessary data points for the entire analysis. MRM Optimization Functions Flow injection analysis enables rapid and unattended optimization of MRM conditions for multiple compounds. The LCMS-85 provides good optimization results even at high speeds. Enter precursor ions. Select parameters to optimize. Unknown product ions Optimization results Efficient Multi-Analyte Data Analysis LabSolutions LCMS software incorporates a Data Browser that allows a user to analyze and compare multiple data sets in a single window. In addition, a Quantitation Browser enables efficient quantitative processing of multiple analytes. Quantitation Browser 16

Optional Software Programs Shimadzu offers a variety of software options to address specific customer requirements. Combining LabSolutions LCMS with these programs improves workflow efficiency. Method Packages A variety of method packages, which include pre-registered MRM parameters with optimized quantitative and reference ions, LC separation parameters, retention times, and peak identification parameters for various compounds, enable efficient implementation of simultaneous multi-component analyses. By eliminating the need to investigate the separation conditions or optimize the MS parameters for each compound, these packages can save laboratories a great deal of method development time. Note: Optimization of analysis parameters will be necessary in some cases when using the LCMS-85. Primary metabolites Lipid mediators Rapid toxicological drug screening Forensic and toxicology-related compounds Residual pesticides Veterinary drugs Water quality analysis 55 metabolites 13 lipid mediators 16 drugs 286 toxic substances 167 pesticides 42 veterinary drugs 44 golf course pesticides, 32 pesticides targeted for water quality control Quan Solution Open Access Software for Triple Quadrupole LC/MS/MS Quantitative Analysis Quan Solution allows users unfamiliar with LCMS software to perform LC/MS/MS analysis using pre-set methods. Utilizing a software wizard, it s possible to start analyses through the presentation of simple-to-follow on-screen instructions. Load samples and start analyses s in the laboratory. Results emailed in PDF format to office. Data file Profiling Solution Software for Profiling Analysis Used to compare and contrast the vast amount of data obtained from multiple chromatographic sets, this software extracts and tabulates all peaks found in multiple data files to create the peak tables required for multivariate analysis. Detected Peak Analytical Instrument Multiple Sets of Data Data Table Multivariate Analysis Software Liquid Chromatograph Mass Spectrometer LCMS-85 17

HPLC Solutions for Mass Spectrometry Shimadzu s wide-ranging HPLC portfolio encompasses all your analytical needs. Shimadzu offers the fastest and most reliable HPLC and UHPLC solutions. Efficient Method Development Nexera Method Scouting Nexera Method Scouting software automates method development using up to 96 unique separation conditions. Allowing up to 16 binary solvent combinations and up to 6 columns, intuitive and user-friendly screens allow the user to quickly select pump flows, gradient conditions, and column valve positions. A sequence table is automatically generated, and the user is spared the tedious and repetitive tasks of manual solvent blending, column removal, and gradient programming. Column and mobile phase selection window Co-Sense Series Direct Analysis of Drugs in Biological Samples Co-Sense for Bio-Analysis (BA) Co-sense for BA is a 2-Dimensional HPLC system equipped with the Shim-pack MAYI-ODS pretreatment column and a unique on-line dilution bypass channel. The system s online sample preparation capabilities reduce labor costs and improve laboratory efficiency. High Sensitivity Analysis of Minor Impurities Co-Sense for Impurities Co-Sense for Impurities features an online trapping and solvent switching capability that allows traditional non-volatile separation techniques, such as phosphate buffer solutions and ion-pair reagents, to be incorporated into the mass spectrometry laboratory. Enhanced sensitivity is achieved through automatic online concentration of the target impurities. Pump Pump Pump Auto sampler Pump Pretreatment column (Shim-pack MAYI-ODS) First dimension analytical column Pump Auto sampler Detector Trap column Analytical column Second dimension analytical column Pump Detector Protein Pharmaceuticals Immobilized methylcellulose surface ODS surface Detector 18

Providing Excellence in Data Quality and Improved Efficiency, Shimadzu s Unique Technologies Achieve a New Global Standard in Mass Spectrometry GCMS-QP21 Ultra GCMS-QP21 SE GCMS-TQ83 LCMS-83 LCMS-84 LCMS-85 LCMS-22 LCMS-IT-TOF imscope The LCMS-85 has been developed with advanced UF technology, and is the flagship model of the Shimadzu UFMS series, which features world-leading speed and sensitivity. The LCMS-85 is the ideal triple quadrupole LC/MS/MS system for High-sensitivity, high-throughput, and simultaneous quantitative and qualitative analysis. Utilizing the same user-friendly interface as HPLC/UHPLC and GC modules, LabSolutions MS workstation software provides intuitive functionality for efficient data processing and an easier, more productive analytical workflow.

LCMS-85 Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation or its affiliates, whether or not they are used with trademark symbol TM or. Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. www.shimadzu.com/an/ For Research Use Only. Not for use in diagnostic procedures. The contents of this publication are provided to you as is without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. Shimadzu Corporation, 213