Determination of Patulin in Apple Juice Using SPE and UHPLC-MS/MS Analysis

Similar documents
Analysis of Limonin in Citrus Juice Using QuEChERS and LC-MS/MS

Identification and Quantification of Psychedelic Phenethylamine 2C Series using SPE and LC-MS/MS

Determination of Chlorophenoxyacetic Acid and Other Acidic Herbicides Using a QuEChERS Sample Preparation Approach and LC-MS/MS Analysis

Simultaneous Determination of Prescription and Designer Benzodiazepines in Urine and Blood by SPE and LC-MS/MS

Extraction of Synthetic and Naturally Occurring Cannabinoids in Urine Using SPE and LC-MS/MS

Removal of Purple Pigmentation from Cannabis using QuEChERS Extraction, ChloroFiltr dspe Clean-up and LC-MS/MS

Simultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using CLEAN UP CCX2 and LC-MS/MS

Pesticide Residue Analysis in Whole Milk by QuEChERS and LC-MS/MS

Simultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using 500 MG CLEAN UP CCX2 and LC-MS/MS

Analysis of Pesticide Residues, Mycotoxins and Potency in Cannabis using QuEChERS Extraction, ChloroFiltr dspe Cleanup and LC-MS/MS

HyperSep Dispersive SPE Products

Determination of 78 Banned or Controlled Racing Industry Drugs in Horse Urine Using SPE and LC-MS/MS

Detection of Low Level of Chloramphenicol in Milk and Honey with MIP SPE and LC-MS-MS

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

Modified QuEChERS Procedure for Analysis of Bisphenol A in Canned Food Products

LC/MS/MS of Trichothecenes and Zearalenone in Wheat Using Different Sample Prep Methods

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Application Note. Author. Abstract. Introduction. Food Safety

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Determination of Multiple Mycotoxins in Grain Using a QuEChERS Sample Preparation Approach and LC-MS/MS Detection

EASIMIP TM PATULIN Product Code: P250 / P250B

Analysis of Acrylamide in French Fries using Agilent Bond Elut QuEChERS AOAC kit and LC/MS/MS

Phenomenex roq QuEChERS Kits. Overview. Spinach Facts

Determination of Pharmaceutical Residues in Bovine Milk via LC MS/MS Following Solid Phase Extraction

Application Note. Authors. Abstract. Food

Comprehensive Study of SLE as a Sample. Preparation Tool for Bioanalysis

Agilent 6470 Triple Quadrupole LC/MS System and EMR-Lipid. The Combination for Confident Pesticide Quantitation. Christoph Mueller

Dienes Derivatization MaxSpec Kit

Determination of Amantadine Residues in Chicken by LCMS-8040

Authors. Abstract. Introduction. Environmental

Rapid Analysis of Bisphenols A, B, and E in Baby Food and Infant Formula Using ACQUITY UPLC with the Xevo TQD

Analytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products)

Analysis of mycotoxins in food matrices using the Agilent Ultivo Triple Quadrupole LC/MS

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Determination of Aflatoxins in Food by LC/MS/MS. Application. Authors. Abstract. Experimental. Introduction. Food Safety

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography

Improved Isolation and Analysis of Mycotoxins from Cereals, Beer and Wine

Rapid and Robust Detection of THC and Its Metabolites in Blood

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

Development and Validation of an UPLC-MS/MS Method for Quantification of Mycotoxins in Tobacco and Smokeless Tobacco Products

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Validation Report 20

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ

Sample Concentration and Analysis of Human Hormones in Drinking Water

Mycotoxin Analysis in Peanut Butter Using Captiva EMR Lipid Cleanup and LC/MS/MS

Detection, Confirmation, and Quantification of Chloramphenicol in Honey, Shrimp and Chicken Using the Agilent 6410 LC/MS Triple Quadrupole

Validation Report 23 B

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases

Multiclass Mycotoxin Analysis in Cheese Using Agilent Captiva EMR Lipid Cleanup and LC/MS/MS

SPE and QuEChERS Method Development. Tina Chambers Christophe Deckers lent.com

Analyze Barbiturates in Urine with Agilent 6430 LC/MS/MS and Poroshell 120 EC-C18

Development and Validation of Multiresidue Pesticide Methods at FDA/CFSAN

Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE. SLE+ Prior to LC/MS-MS Analysis

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Agilent Sample Preparation The Pesticide Analysis Workflow

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Determination of Ractopamine and Clenbuterol in Beef Samples

Application Note. Introduction. Analysis of Total Aflatoxins in Food by HPLC and UHPLC

Enrichment of Phospholipids from Biological Matrices with Zirconium Oxide-Modified Silica Sorbents

Fast quantitative Forensic Analysis of THC and its Metabolites in Biological Samples using Captiva EMR- Lipid and LC/MSMS

UCT SELECTRA AQUEOUS C18 HPLC COLUMNS

UCT STYRE SCREEN INNOVATION THROUGH CHEMISTRY

EASI-EXTRACT BIOTIN Product Code: P82 / P82B

Comparison of Biotage Extrahera vs. Manual Sample Processing Using a Vacuum Manifold

Extraction of 25-hydroxy Vitamin D from Serum Using ISOLUTE. PLD+ Prior to LC-MS/MS Analysis

[ APPLICATION NOTE ] Oasis PRiME HLB Cartridge for Cleanup of Infant Formula Extracts Prior to UPLC-MS/MS Multiresidue Veterinary Drugs Analysis

Rapid Screening and Quantitation of Postharvest Fungicides on Citrus Fruits Using AxION DSA/TOF and Flexar SQ MS

Mycotoxin Analysis in Infant Formula Using Captiva EMR Lipid Cleanup and LC/MS/MS

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS

Validation Report 8. EURL for Cereals and Feeding stuff National Food Institute Technical University of Denmark

Analysis of Food Sugars in Various Matrices Using UPLC with Refractive Index (RI) Detection

Author. Introduction. Abstract

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

Modified QuEChERS for HILIC LC/MS/MS Analysis of Nicotine and Its Metabolites in Fish

Authors. Abstract. Forensic Toxicology. Irina Dioumaeva, John M. Hughes Agilent Technologies, Inc.

Filtration Approaches to Sample Preparation and Cleanup. Golnar Javadi Application Engineer Sample Preparation Products

Determination of Sulfonamide Antibiotics in Bovine Liver Using Agilent Bond Elut QuEChERS EN Kits by LC/MS/MS

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

Neosolaniol. [Methods listed in the Feed Analysis Standards]

MAS-QuEChERS. Bonna-Agela. MAS-QuEChERS. Official Website

EURL-SRM - Analytical Method Report. Analysis of Residues of Carbofuran (sum) Using QuEChERS Method

Application Note No. 119/2013 Determination of bisphenol A in preserved food SpeedExtractor E-916: Determination of bisphenol A in preserved food

Matrix-induced Signal Enhancement of Propamocarb in LC-MS/MS

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer

New SPE Sorbent for Clean-up of Fusarium Toxin-contaminated Cereals & Cereal-based Foods, Bond Elut Mycotoxin

Accurate quantification of regulated mycotoxins by UHPLC-MS/MS and screening for 200+ mycotoxins in food and feed.

Analysis of HMF by HPLC

Determination of N-Nitrososarcosine (NSAR) in tobacco

Analysis of Polar Pesticides Using a Mixed-Phase Mode HPLC Column

Transcription:

Determination of Patulin in Apple Juice Using SPE and UHPLC-MS/MS Analysis UCT Part Numbers ECHLD126-P ENVIRO-CLEAN HLDVB mg/6ml SPE cartridge PE Frit SLDAID21-18UM Selectra DA UHPLC column ( 2.1 mm, 1.8 µm) SLDAGDC-18UM Selectra DA guard cartridge ( 2.1 mm, 1.8 µm) SLGRDHLDR Guard cartridge holder Summary: Patulin (Figure 1) is a naturally occurring mycotoxin that is produced by several species of fungi, such as Aspergillus, Penicillium and Byssochlamys. It typically grows on fruit, including apples, pears, peaches and grapes, but has also been reported in vegetables and cereal grains. Patulin has been implicated as a possible carcinogen and teratogen, although an official designation has not yet been made. The main risk arises when unsound fruit is used for the production of juices and other processed products. The amount of patulin in apple juice is also viewed as a measure of the quality of the apples used in production. Figure 1. Structure of patulin. The World Health Organization, U.S. Food and Drug Administration (FDA) and European Union (EU) have suggested a maximum limit of patulin in apple juice and apple juice ingredients at µg/kg. Furthermore, the EU has set a limit of 25 µg/kg in solid apple products and µg/kg in baby food (EC 1881/6). This application note outlines a simple solid-phase extraction (SPE) procedure for the low level detection of patulin in apple juice. Analysis is carried out by UHPLC-MS/MS using a Selectra DA column. The unique chemistry of the Selectra DA column, which contains a polyaromatic stationary phase, provides a high degree of retention and selectivity for aromatic compounds and improved retention of polar compounds.

Sample Pretreatment: No additional preparation is necessary for filtered apple juice or clear unfiltered apple juice. Cloudy unfiltered apple juice should be centrifuged prior to application to the SPE cartridge ( rpm for 5- min). SPE Procedure: 1. SPE conditioning a) 1 3 ml methanol. b) 1 3 ml deionized/ultrapure water. 2. Sample extraction Add 5 ml of apple juice to the SPE cartridge. If necessary, apply a low vacuum or positive pressure to force the sample through the SPE cartridge at 5 ml/min. 3. Wash cartridge a) 1 2 ml 1% sodium bicarbonate. The high ph of the buffer aids in the removal of sugars that are co-extracted onto the SPE cartridge. b) 1 2 ml 1% acetic acid. Reduces the ph of the sample (patulin is unstable at high PH). c) Dry SPE cartridge under full vacuum for minutes to remove excess water. Do not overdry as this can result in reduced recovery of patulin. 4. Elution a) 1 3 ml n-hexane/acetone (7:3, v/v). b) Evaporate to dryness at 35- C under a gentle stream of nitrogen (the elution solvent is very volatile and is rapidly evaporated). c) Reconstitute in 1 ml methanol/water (1:1, v/v) containing.1% acetic acid or other suitable solvent solution. LC-MS/MS Parameters: Instrumentation HPLC system Thermo Scientific TM Dionex TM Ultimate TM UHPLC MS system Thermo Scientific TM TSQ Vantage TM (MS/MS) HPLC column UCT Selectra DA, 2.1 mm, 1.8 µm (p/n: SLDAID21-18UM) Guard column UCT Selectra DA, 2. mm, 1.8 µm (p/n: SLDAGDC-18UM) Guard column holder p/n: SLDGRDHLDR Column temperature C Flow rate µl/min Injection volume 5 µl

Mobile Phase Gradient % Mobile Phase A Water % Mobile Phase B Methanol. 95 5 2. 5 95 3.5 5 95 3.6 95 5 6. 95 5 MRM transitions (ESI - ) Compound t R (min) Precursor ion Product ion 1 Product ion 2 Patulin 153. 9. 81. RT:. - 3.49 SM: 5G NL: 2.36E4 m/z= 8.53-9.53 F: - c ESI 9.29-9.31] MS 1.62 1.85 1.99 2. 2.65 2.83 3.3 3.18 3.43 NL: 9.E3 m/z=.54-81.54 F: - c ESI 9.29-9.31] MS 2.52 2.71 2.83 2.62 3.13 1.94 2.3 3.3 3.24 1.71 1. 3. NL: 3.22E3 m/z= 52.59-53.59 F: - c ESI 9.29-9.31] MS 2.54 2.71 2.85 2.16 3.5 1.96 3.16 2.95 3.26 1.56 1.68 1.84 3.39..2.4.6.8 1. 1.2 1.4 1.6 1.8 2. 2.2 2.4 2.6 2.8 3. 3.2 3.4 Figure 2. Chromatogram of Patulin at µg/l.

Results: Recovery and Reproducibility 5 µg/kg µg/kg Sample 1 79..3 Sample 2 87. 94.7 Sample 3 82.2 83.1 Sample 4 81.1 86.8 Sample 5 86.4 85.7 Sample 6 78.1 99.9 Mean Recovery (%) 82.3 91.7 RSD (%) 4.54 8.2 Figure 3. Effect of wash and elution solvent on cleanliness of final extract. Left picture - Rinsing of SPE sorbent with % water (L) vs. 1% sodium bicarbonate (R). Right picture: Eluting with % methanol (L) vs. n-hexane/acetone (7:3, v/v) (R). Patulin Y = 7157.55+2697.2*X R^2 =.9988 W: 1/X 6 Area 5 1 2 ng/ml Figure 4. Example of an eight-point matrix-matched calibration curve (1-2 ng/ml). 63-1-1 UCT, LLC 2731 Bartram Road Bristol, PA 7.385.3153 215.781.9255 www.unitedchem.com Email: methods@unitedchem.com UCT, LLC 16 All rights reserved

Determination of Patulin in Processed Foods Using QuEChERS Extraction and UHPLC-MS/MS Analysis UCT Part Numbers ECMSSC-MP Mylar pouch containing 4g MgSO4 and 1g NaCl CUMPSC1875CB2CT 2mL dspe tube with 1mg MgSO4, mg PSA, mg C18 and 7.5mg GCB or ECQUEU615CT 15mL dspe tube with mg MgSO4, 1mg PSA and 45mg GCB SLDAID21-18UM Selectra DA UHPLC column ( 2.1 mm, 1.8 µm) SLDAGDC-18UM Selectra DA guard cartridge ( 2.1 mm, 1.8 µm) SLGRDHLDR Guard cartridge holder Summary: Patulin (Figure 1) is a naturally occurring mycotoxin that is produced by several species of fungi, such as Aspergillus, Penicillium and Byssochlamys. It typically grows on fruit, including apples, pears, peaches and grapes, but has also been reported in vegetables and cereal grains. Patulin has been implicated as a possible carcinogen and teratogen, although an official designation has not yet been made. The main risk arises when unsound fruit is used for the production of juices and other processed food products. Figure 1. Structure of patulin. The World Health Organization, U.S. Food and Drug Administration (FDA) and European Union (EU) have suggested a maximum limit of patulin in apple juice and apple juice ingredients at µg/kg. Furthermore, the EU has set a limit of 25 µg/kg in solid apple products and µg/kg in baby food (EC 1881/6). This application note outlines a QuEChERS procedure for the detection of patulin in processed food products. An apple-based baby food product was used as a representative sample matrix. The inclusion of graphitized carbon black (GCB) in the dispersive-spe (dspe) cleanup step produces a clean sample extract. Analysis is carried out by UHPLC-MS/MS using a Selectra DA column. The unique chemistry of the Selectra DA column, which contains a polyaromatic stationary phase, provides a high degree of retention and selectivity for aromatic compounds and improved retention of polar compounds.

QuEChERS Procedure: Sample Extraction: 1. Weigh g of sample into a ml polypropylene centrifuge tube. 2. Add ml of acetonitrile. 3. Add the contents of the ECMSSC-MP Mylar pouch and shake for a minimum of 1 minute (by hand or mechanically). 4. Centrifuge the samples at g for 5 minutes. Sample Clean-up of 1 ml Extract: 1. Transfer 1 ml of supernatant to a 2 ml dspe tube (CUMPSC1875CB2CT). 2. Vortex the sample for seconds. 3. Centrifuge the samples at g for 5 minutes. 4. Transfer - µl of purified supernatant into an autosampler vial (filter if desired). Sample Clean-up of 5 ml Extract (for increased sensitivity): 1. Transfer 6 ml of supernatant to a 15 ml dspe tube (ECQUEU615CT). 2. Vortex the sample for 1 minute. 3. Centrifuge the samples at g for 5 minutes. 4. Transfer 5 ml of purified supernatant into a glass tube and evaporate the sample to 1 ml at C under a gentle stream of nitrogen. 5. Transfer the sample into an autosampler vial (filter if desired). LC-MS/MS Parameters: HPLC system MS system HPLC column Guard column Guard column holder Column temperature C Flow rate Injection volume 5 µl Instrumentation Thermo Scientific TM Dionex TM Ultimate TM UHPLC Thermo Scientific TM TSQ Vantage TM (MS/MS) UCT Selectra DA, 2.1 mm, 1.8 µm (p/n: SLDAID21-18UM) UCT Selectra DA, 2.1 mm, 1.8 µm (p/n: SLDAGDC-18UM) p/n: SLGRDHLDR µl/min Mobile Phase Gradient % Mobile Phase A Water % Mobile Phase B Methanol. 95 5 2. 5 95 3.5 5 95 3.6 95 5 6. 95 5 Note: no mobile phase additive was used as it was found to give better signal intensity in ESI - for patulin.

MRM transitions (ESI - ) Compound t R (min) Precursor ion Product ion 1 Product ion 2 Patulin 153. 9. 81. RT:. - 3.49 SM: 5B NL: 5.89E3 m/z= 8.53-9.53 F: - c ESI 9.29-9.31] MS 1. 2.9 2.52 2.64 1.98 2.84 2.97 3.19 3.39 NL: 2.18E3 m/z=.54-81.54 F: - c ESI 9.29-9.31] MS 1. 1.95 2. 2.66 2.82 2.94 3.6 3.22 NL: 7.54E2 m/z= 52.59-53.59 F: - c ESI 9.29-9.31] MS 2.52 2.74 2.84 1. 1.73 1.91 2. 2.12 2.94 3. 3.19 3.35..2.4.6.8 1. 1.2 1.4 1.6 1.8 2. 2.2 2.4 2.6 2.8 3. 3.2 3.4 Figure 1. Chromatogram of an extracted baby food sample fortified with patulin at µg/kg. Results: Recovery and Reproducibility µg/kg a µg/kg b Sample 1 2.3.1 Sample 2 1.8 83.4 Sample 3 99.2 86. Sample 4 3.8 88.3 Sample 5 4.8 87.9 Sample 6 6.1 83.9 Mean Recovery (%) 3. 86.6 RSD (%) 2.35. a used 5 ml of sample extract and included a concentration step. b used 1 ml of sample extract and no concentration step. 63-3-1 UCT, LLC 2731 Bartram Road Bristol, PA 7.385.3153 215.781.9255 www.unitedchem.com Email: methods@unitedchem.com UCT, LLC 14 All rights reserved