Universal Couchtop. for safe, efficient treatment planning + imaging. Long Extension. 1 Piece

Similar documents
Universal Couchtop. for safe, efficient treatment planning + imaging. 5 Year Warranty. Long Extension. 1 Piece

Protura Robotic Patient Positioning System. for efficiency + performance

SBRT Patient Positioning + Immobilization Solutions. for improved patient outcomes + clinical efficiencies

SBRT Patient Positioning + Immobilization Solutions. for improved patient outcomes + clinical efficiencies

Solutions Guide Volume 2.0 Comprehensive Motion Management Solutions

Breast + Thorax Positioning. for accuracy, reproducibility + patient comfort

Solutions Guide. Volume 3.0

Unrivaled, End-to-End

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

EXACTRAC HIGHLY ACCURATE PATIENT MONITORING

FROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE. Geoffrey S. Ibbott, Ph.D. June 20, 2017

Varian Treatment. Streamlined Treatment Delivery Management Application. Specifications

I. Equipments for external beam radiotherapy

7/10/2015. Acknowledgments. Institution-specific TG-142? AAPM:Task Group-142. Failure-Mode & Effects Analysis

PINPOINTING RADIATION THERAPY WITH THE PRECISION OF MR.

ph fax

Work partially supported by VisionRT

Ingenia MR-RT. MR Systems. The comprehensive MR-sim solution to fit your planning

Varian Edge Experience. Jinkoo Kim, Ph.D Henry Ford Health System

Herlev radiation oncology team explains what MRI can bring

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

MAX-HD SRS PHANTOM THE COMPREHENSIVE END-TO-END SRS PHANTOM SCAN PLAN LOCALIZE TREAT. distributed by:

8/2/2018. Disclosure. Online MR-IG-ART Dosimetry and Dose Accumulation

STEREOTACTIC DOSE VERIFICATION PHANTOM VERSATILE STEREOTACTIC QA PHANTOMS

Risk-based QM for Incorrect Isocenter at Day 1 Setup. TG 100 risk based QM development Process Mapping

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT

Product Catalog. Patient Positioning. Patent(s) Pending

Image Registration for Radiation Therapy Applications: Part 2: In-room Volumetric Imaging

Radiosurgery. Most Important! 8/2/2012. Stereotactic Radiosurgery: State of the Art Technology and Implementation Linear Accelerator Radiosurgery

THE AIO SOLUTION ALL-IN-ONE PATIENT POSITIONING SYSTEM

Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, Pamela Myers, Ph.D.

Nuclear Associates

Credentialing for the Use of IGRT in Clinical Trials

Eric E. Klein, Ph.D. Chair of TG-142

Elekta Synergy Digital accelerator for advanced IGRT

SAGITTILT PRONE BREAST SOLUTION

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

CHAPTER 5. STUDY OF ANGULAR RESPONSE OF asi 1000 EPID AND IMATRIXX 2-D ARRAY SYSTEM FOR IMRT PATIENT SPECIFIC QA

Image Guided in Radiation Therapy (IGRT) Chumpot Kakanaporn Med Phys Radiation Oncology Siriraj Hospital

7/31/2012. Volumetric modulated arc therapy. UAB Department of Radiation Oncology. Richard Popple, Ph.D.

Implementation of advanced RT Techniques

Special Procedures Rotation I/II SBRT, SRS, TBI, and TSET

Radiation Oncology Accessory Catalog. vision possible. Enhancing clinical workflow

Stereotaxy. Outlines. Establishing SBRT Program: Physics & Dosimetry. SBRT - Simulation. Body Localizer. Sim. Sim. Sim. Stereotaxy?

Quality assurance in external radiotherapy

A method to predict patient specific table coordinates for quality assurance in external beam radiation therapy

Imaging Rotation. University of Michigan Department of Radiation Oncology Division of Radiation Physics. Resident:

Case Study. Institution Farrer Park Hospital

8/3/2016. The EPID Strikes Back! - EPID In-Vivo Dosimetry. EPID Research Number of Publications. Why EPID in-vivo? Detectable errors: patient

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Can the compact economical Nano-X linear accelerator system be a solution for improving access to radiotherapy globally?

Global Radiation Therapy Market Report

8/2/2017. Objectives. Disclosures. Clinical Implementation of an MR-Guided Treatment Unit

IMRT/IGRT Patient Treatment: A Community Hospital Experience. Charles M. Able, Assistant Professor

Varian Acuity BrachyTherapy Suite One Room Integrated Image-Guided Brachytherapy

Clinical Precision for Best Cancer Care. Dee Mathieson Senior Vice President Oncology Business Line Management

SunCHECK Patient Comprehensive Patient QA

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

Technique For Plan Quality and Efficiency Using VMAT Radiosurgery For Patients with Multiple Brain Metastases

In-Room Radiographic Imaging for Localization

1 : : Medical Physics, Città della Salute e della Scienza, Torino, Italy

Solutions

In-Room Radiographic Imaging for Localization

SHIELDING TECHNIQUES FOR CURRENT RADIATION THERAPY MODALITIES

Motion gating and tracking techniques: overview and recent developments

place needle guide insert

Objective. Evaluation of Linear Accelerator Performance Standards using an Outcome Oriented Approach. Linac performance standards*

Intensity modulated radiotherapy (IMRT) for treatment of post-operative high grade glioma in the right parietal region of brain

Imaging of Scattered Radiation for Real Time Tracking of Tumor Motion During Lung SBRT

SOUTHAMPTON UNIVERSITY HOSPITALS NHS TRUST CANCER CARE PHASE 2A+ BUSINESS CASE

Clinical Implementation of a New Ultrasound Guidance System. Vikren Sarkar Bill Salter Martin Szegedi

JP MORGAN HEALTHCARE CONFERENCE DOW R. WILSON President and Chief Executive Officer 1 FOR INVESTOR USE ONLY

Elekta Infinity. Digital accelerator for advanced treatments. Redefining treatment precision, speed and control

Which Planning CT Should be Used for Lung SBRT? Ping Xia, Ph.D. Head of Medical Physics in Radiation Oncology Cleveland Clinic

Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry

QUALITY ASSURANCE IN RADIOTHERAPY THERAPY EQUIPMENT

IMRT - Intensity Modulated Radiotherapy

Economic Implications of Advancements in Radiation Technology. Dramatic Growth of RT Capacity in the US

Importance of daily portal imaging for Head and Neck IMRT treatments. Luciant Wolfsberger Brigham & Women s Hospital

A new geometric and mechanical verification device for medical LINACs

SUPERIORITY OF A REAL TIME PLANNING TECHNIQUE OVER IMAGE GUIDED RADIATION THERAPY FOR THE TREATMENT OF PRIMARY PROSTATE CANCERS

Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry

Introduction. Modalities used in imaging guidance. Flat panel detector. X-ray Imaging Dose to Patients in the Era of Image-Guided Radiation Therapy

Debate Motion. Theoretical benefits of VMAT: Real Costs of VMAT. "Arc Based Techniques Will Make Conventional IMRT Obsolete

Implementing SBRT Protocols: A NRG CIRO Perspective. Ying Xiao, Ph.D. What is NRG Oncology?

Patient and Linac QA - present and the future

Online Care, Online Control, Online Confidence

Hybrid VMAT/IMRT Approach to Traditional Cranio-Spinal Irradiation (CSI): A Case Study on Planning Techniques and Delivery

IGRT Protocol Design and Informed Margins. Conflict of Interest. Outline 7/7/2017. DJ Vile, PhD. I have no conflict of interest to disclose

Integrating the Radixact into a Highly Comprehensive Center

VARIAN ONCOLOGY. RapidArc. One revolution is all it takes.

Intensity-Modulated and Image- Guided Radiation Treatment. Outline. Conformal Radiation Treatment

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

Reena Phurailatpam. Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery

Leksell Gamma Knife Icon contributes to significant growth, greater efficiency and an enhanced patient experience

IGRT1 technologies. Paweł Kukołowicz Warsaw, Poland

UNIVERSITY OF WISCONSIN-LA CROSSE Graduate Studies

What is the CyberKnife System?

Learning objective. Outline. Acknowledgements. KV CBCT Imaging Part I. R Hammoud AAPM 2008 CE-Therapy (SAM) 1

QA - Prone Breast Board and Its Dosimetric Effect. Inter-fractional Prone Breast Setup Variation

Transcription:

Universal Couchtop for safe, efficient treatment planning + imaging Long Extension 1 Piece

Extensions to Treat Many Disease Sites Universal Couchtop allows full flexibility with seven extension options to treat many patients and disease sites throughout the day. The couchtop features a unique profile allowing for easy attachment of all CIVCO Body Pro-Lok SBRT bridges and additional extension options for trupoint ARCH SRS/SRT, head & neck and other treatment types. Rectangular Extension Optional Rectangular Extension with embedded wires ensures patient alignment All Long Extensions (SBRT Immobilization) Type-S Extension Compatible with Type-S Thermoplastics, including the ClearVision open face mask designed for use with vision/camera systems Posifix Extension Compatible with Posifix Thermoplastics and trupoint ARCH SRS/SRT System Kevlar Extension Compatible with Varian s Calypso System Posifix Extension (SRS/SRT Immobilization) Grid Extension Helps minimize surface dose and skin reactions UCT Head Extension Extends the patient an additional 17 cm Varian End Plate Allows the use of various QA and SRS devices. Type-S & Posifix Extensions (Head & Neck Positioning)

Junction, Rail and Artifact-free The Universal Couchtop is a modern and comprehensive solution for enabling advanced treatments in your clinic. Specifically designed to answer the demands of IGRT delivery, the Universal Couchtop Long Extension contains no rails or junctions in the treatment area to help facilitate better dose delivery and target coverage. Large treatment area of 47 inches (119 cm) Utilizes Prodigy 2 indexing at 7 cm increments Low attenuation and surface dose Self-locking extension seam located outside of treatment field Convenient wall storage device (below) holds up to four extensions The implementation of UCT has allowed us to introduce kv and CBCT imaging on our treatment units. It is the preferred treatment unit for all complex patients including head and neck and lung treatments. - Aniko Cooper, Director of Radiation Therapy Services, North Queensland Oncology Service, Douglas, Australia We really love our new UCT. It saves a lot of work, and I feel more confident with the weight limit as opposed to our old table top. We used to have to turn our table to accommodate different types of setups, and now we don t. -Susan Chamberlin, R.T.T., Buckeye Radiation Oncology, Columbus, Ohio

Dosimetrically Matched Universal Couchtops DoseMatch Technology Universal Couchtop is available in dosimetrically matched couchtops for most major CT and Linac models to provide seamless transition from simulation to treatment. Reduce set-up and treatment errors Installing the same Universal Couchtop on all department pedestals also will offer: Dose attenuation Deflection Indexing Immobilization device attachment Scan or treat patients on any CT or Linac Installing matching couchtops allows patients to be scanned or treated on any CT or Linac as required. This is ideal when machines are down or departments are trying to manage patient throughput. VARIAN ELEKTA GE PHILIPS SIEMENS TOSHIBA CIVCO s dosimetrically matched Universal Couchtops give us more confidence in dose calculations when planning patients who will be treated on the linac. Not having to use overlays has definitely provided us additional conveniences. - Brian Smaga, Radiation Therapist, Agnesian Healthcare, Fond Du Lac, Wisconsin One can minimize or even eliminate the effort needed to model the couch by installing matching couch tops in the CT simulator and linear accelerator. - AAPM Task Group 176 Universal Couchtop 1 Piece The Universal Couchtop 1 Piece is an ideal IGRT and SBRT solution with a uniform design and no junctions. This couchtop offers a dosimetrically matched couchtop for most major CT and Linac models. No extension or seams Low attenuation and surface dose Economic option for facilities with multiple linear accelerators and CTs Allows for attachment of Body Pro-Lok SBRT bridges and accessories for SBRT Immobilization Utilizes Prodigy 2 indexing at 7 cm increments 1 Piece

UCT LE Statistics UCT 1 Piece Statistics Load Rating Entire System: 220 kg/484 lbs Extension Only: 178 kg/392 lbs Load Rating Entire System: 200 kg/444 lbs Attenuation Gantry () (5 x 5) 180 0.971 0.969 200 / 160 0.968 n/a 210 0.967 n/a 220 / 140 0.962 n/a Attenuation Gantry () (5 x 5) 180 0.971 0.969 200 / 160 0.968 n/a 210 0.967 n/a 220 / 140 0.962 n/a Surface Dose Surface Dose 18MV 18 MV Open Field 19.1% 30.5% 16.1% 20.6% UCT LE 94.1% 97.2% 69.9% 79.4% Posi Extension P1 82.6% 89.7% 56.9% 69.4% Posi Extension P2 89.6% 93.2% 64.6% 73.6% 18MV 18 MV Open Field 19.1% 30.5% 16.1% 29.6% UCT 1 Piece 94.1% 97.2% 69.9% 79.4% Deflection The Universal Couchtop Long Extension contributes less than 1 mm of deflection to the system following IEC 60976 (2007) Section 15.2.2 The Universal Couchtop 1 Piece meets the deflection standards and requirements of IEC 60976 (2007) Section 15.2.2 on the Varian Exact couch Attenuation and surface dose values are approximate due to variation in machine characteristics.

Global Sales Office 1401 8 th Street SE Orange City, IA 51041 800.842.8688 +1 712.737.8688 info@civcort.com www.civcort.com COPYRIGHT 2016. CIVCO AND POSIFIX ARE REGISTERED TRADEMARK OF CIVCO MEDICAL SOLUTIONS. BODY PRO-LOK, BODY PRO-LOK ONE, CLEARVISION, DOSEMATCH TECHNOLOGY, PRODIGY, TRUPOINT ARCH, TYPE-S AND UNIVERSAL COUCHTOP ARE TRADEMARKS OF CIVCO. ALL OTHER TRADEMARKS ARE PROPERTY OF THEIR RESPECTIVE OWNERS. ALL PRODUCTS MAY NOT BE LICENSED IN ACCORDANCE WITH CANADIAN LAW. 2016P1108 REV. A