PRODUCT RATIONALE & SURGICAL TECHNIQUE

Similar documents
Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)

DURALOC. Acetabular Cup System. Surgical Technique

AUTOBLOQUANTE AUTOBLOQUANTE. Product Rationale Surgical Technique

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Cemented Cup. Surgical Technique

This publication is not intended for distribution in the USA.

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

ACETABULAR CUP SURGICAL TECHNIQUE

PINNACLE Hip Solutions. Surgical Techniques

Approach Patients with Confidence

CC TRIO VERSAFITCUP. Surgical Technique. each to their own. Hip Knee Spine Navigation

Manza Cup HA SURGICAL TECHNIQUE.

PINNACLE REVISION CUP SYSTEM

Rx90 Total Hip System Acetabular Series

Optimum implant geometry

CORAIL HIP SYSTEM SURGICAL TECHNIQUE

Approach Patients with Confidence

Exeter X3 RimFit Acetabular Cup

Optimum implant geometry

SUMMIT and DURALOC. Clinical Summary

HIP SYSTEM SURGICAL TECHNIQUE

AML Hip System. Design Rationale/ Surgical Technique

Minimally Invasive System for Total Hip Arthroplasty. Surgical Technique

RECOVERY. P r o t r u s i o

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Featuring. Technology. Product Rationale

pact SYSTEM Surgical Technique HEMISPHERICAL CEMENTLESS CUP SYSTEM MULTI-HOLE & RIM-HOLE Hip Knee Spine Navigation

Bone Preservation Stem

THE ATTUNE REVISION FIXED BEARING KNEE SYSTEM

Exeter Contemporary Flanged Cup. Exeter. Providing Solutions

Surgical Technique r5.indd 1 12/8/10 10:36 AM

SURGICAL TECHNIQUE IMPROVED WEAR REDUCTION PROVEN FIXATION PRECISE INSTRUMENTATION RELIABILITY

Operative Technique Crown Cup Acetabular System

Trinity. Advanced Bearing Acetabular System Surgical technique

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

Surgical Technique. Cup System

AVANTEON. Operative Technique & Catalogue Information AVANTEON

TaperFit. Cemented Total Hip Replacement Surgical technique

Triple Tapered Stabilised Hip C-STEM AMT. Surgical Technique

FLH183 04/08. Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom. Tel. +44 (0) Fax: +44 (0)

ARTICUL/EZE Mini Taper. C-STEM AMT Hip. Design Rationale & Surgical Technique

THE ATTUNE REVISION ROTATING PLATFORM KNEE SYSTEM

Dual Mobility System Surgical technique

Dual Mobility System Evaluation surgical technique

Cements and Accessories. Product Catalogue

LAMINA SPREADER SURGICAL TECHNIQUE

Metasul LDH Large Diameter Head

Femoral Revision Algorithm. A practical guide for the use of the CORAIL Hip System in femoral revision surgery

Product Information. *smith&nephew POLARCUP Dual Mobility System

CERAMIC-ON-METAL. References: Cat No: version 2

EVOLVING OUR HERITAGE, MEETING YOUR NEEDS. Surgical Technique

Impingement in THA. Georgi I. Wassilew. Orthopaedic Department, Centrum für Muskuloskeletale Chirurgie Univ.-Prof. Dr. med. C.

DePuy International Ltd St Anthony s Road Leeds LS11 8DT England Tel: +44 (0) Fax: +44 (0)

S U R G I C A L T E C H N I Q U E

DESIGN RATIONALE AND SURGICAL TECHNIQUE

Optimum implant geometry

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

CORAIL UPGRADE KIT. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Fixed and Variable Geometry Total Shoulder Arthroplasty

THE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation

CORAIL Hip System. Clinical Summary

Hip Resurfacing System

CHARNLEY MODULAR HIP SYSTEM SURGICAL TECHNIQUE. This publication is not intended for distribution in the USA.

AMT ARTICUL/EZE MINI TAPER

Bi-Polar 22.2mm & 28mm System - Operative technique

Scan Bi-Polar 22/28. Operative Technique

RECLAIM REVISION SOLUTIONS

Clinical Evaluation Surgical Technique

Efficacy Innovation ABG II. Brochure. Surgical Protocol. Cemented Stem

Optimizing function Maximizing survivorship Accelerating recovery

Cementless femoral stem type SF

Product Rationale. Where Strength and Modularity Connect

Bone Bangalore

CHARNLEY Wires. Surgical Techniques

TOTAL HIP REPLACEMENT:

PINNACLE Acetabular Cup System

Surgical Technique CHARNLEY CHARNLEY, THE WORLD S MOST SUCCESSFUL HIP IMPLANT

CORAIL Upgrade Kit. Surgical Technique

CUTTING GUIDE SYSTEM PRODUCT RATIONALE. Custom-Made Patient Instruments for Total Knee Replacement

Progeny Hip Stem. Surgical Protocol and Product Specifications

JOINT RECONSTRUCTION PORTFOLIO OVERVIEW

Trident All Poly Acetabular System

Integral 180 Surgical Technique

SURGICAL TECHNIQUE. Protrusio Cage A COMPREHENSIVE ACETABULAR REVISION SYSTEM

PROCOTYL E Acetabular Cup System. Modular to Fit Patient s Anatomy. Versatile for Revisions.

CLINICAL PAPER / ORTHOPEDIC

Revision. Hip Stem. Surgical Protocol

StelKast Acetabular. Surgical Protocol and Product Specifications. Including ProForm, Provident, Provident Apical Threaded Hole & Systems

Does the self-centering mechanism of bipolar hip endoprosthesis really work in vivo?

Technique Guide Hip Resurfacing System

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

Acetabular Cup System. Clinical Summary

Duraloc CONSTRAINED LINER

Surgical. Technique. AEQUALIS Spherical Base Glenoid. Shoulder Prosthesis.

INSTRUMENTS. Product Rationale

Transcription:

This publication is not intended for distribution in the USA. PRODUCT RATIONALE & SURGICAL TECHNIQUE

THE PRODUCT OF LONG-TERM CLINICAL EXPERIENCE The TRILOC cemented UHMWPE cup is a direct descendant of Prof ME Müller s 1970 s design. Circumferential grooves increase surface area for enhanced cement contact while polar-equatorial grooves provide rotational stability. An X-ray marker wire allows post-operative assessment of position. 1 DePuy Synthes TRILOC Product Rationale and Surgical Technique

PRE-OPERATIVE TEMPLATING The primary goal of total hip arthroplasty is the anatomic reconstruction of the hip joint, resulting in favourable prosthetic joint load and function. Mechanically, the goals are to create a stable articulation with an optimised range of motion, restore biomechanics for muscular efficiency and equalise limb lengths. Meeting these goals begins with a thorough analysis of the hip with comparison to the contralateral side in anteroposterior (A/P) and lateral projections. Clear AP and lateral radiographs should be available prior to intervention. TRILOC templates, available in 115% magnification, allow assessment of the most likely size of cup to be implanted. The cup should be placed so that the head centre is as near to the anatomical position as possible and the most inferior part of the cup should normally be at the level of the bottom of the teardrop. The radiographs should clearly demonstrate the acetabular configuration and the endosteal and periosteal contours of the femoral head, neck and proximal femur (Figure 1). Frequently, the affected hip is fixed in external rotation, which leads one to underestimate the amount of offset present. In this situation it may be helpful to template the normal hip. Take into consideration any anatomical anomaly, dysplasia, previous fracture or leg length discrepancy. It is important to note that the template is a guide only. The final implant size and position will be determined intraoperatively. Figure 1 Properly positioned acetabular template TRILOC Product Rationale and Surgical Technique DePuy Synthes 2

CUP POSITIONING Peer reviewed publications highlight the importance of acetabular component positioning in relation to short and long term outcomes during total hip arthroplasty for all types of bearing materials. 1-5 Cup positioning should be varied to optimise fixation, range of motion, dislocation resistance and to minimise the likelihood of subluxation, impingement and edge loading. This may be assessed during pre-operative planning, acetabular preparation and cup trialling. Sub-optimal component positioning may lead to edge loading, dislocation, increased wear, and polyethylene fracture. 1-5 The target cup inclination (as measured on radiographs) should be 45 taking into account local soft tissue and anatomic landmarks. The target cup anteversion (as measured on radiographs) should be 15 20 taking into account local soft tissue and anatomic landmarks. 3 DePuy Synthes TRILOC Product Rationale and Surgical Technique

ACETABULAR PREPARATION The capsule is excised from around the acetabulum and a curette is used to clear any remaining soft tissues and osteophytes from the rim and bed of the acetabulum. The acetabulum is then progressively reamed, beginning with the smallest diameter hemispherical reamer, to remove the articular cartilage and any medial osteophytes. Reaming is stopped when healthy, bleeding subchondral bone is exposed and a symmetrical, hemispherical dome is achieved. The reamers should be introduced in 45 of abduction (Figure 1) and 15 of anteversion. Note: If the posterior approach is employed, it should be remembered that this position puts the pelvis in approximately 20 of anteversion which must be compensated for during acetabular reaming and cup placement. 45 Multiple drill holes are made in the roof of the acetabulum using the Acetabular Prep Drill provided to encourage penetration of the cement into these keyholes and the interstices of the bone. Note: Care should be taken to avoid breaching the medial wall of the acetabulum. The edges of the drill holes are smoothed and any debris is removed using a small curette. TRIAL SIZING A trial cup that corresponds in diameter to the final acetabular reamer is screwed to the handle provided and used to confirm the diameter of the acetabulum (Figure 2). Figure 2 TRILOC Product Rationale and Surgical Technique DePuy Synthes 4

CUP IMPLANTATION Use pulse or continuous lavage within the acetabulum to remove fat and debris from the cancellous bone interface. Employ suction and dry swabs to clean and dry the bone surface (Figure 3). When the acetabular surface is dry and the bone surface is open, pack the socket with swabs. These will prevent blood clots adhering to the bone and leave the surface ready for cement introduction. Screw either the Neutral Alignment Guide or the Standard Alignment Guide to the two-piece Inserter provided. The definitive cup is then placed on this assembly for steering into position later (Figure 4). Note: The diameter of the definitive cup is normally 4 mm less in diameter than the final acetabular reamer. This ensures a sufficient and consistent thickness of cement mantle. Figure 3 Cement is introduced into the keyholes and the bed of acetabulum and the cup is inserted. The cup should be introduced in 45 of abduction (using the two-piece Inserter provided) and 15 of anteversion (Figure 4). Note: Cup orientation in the patient depends on patient position. The alignment guides do not allow for variation in patient position with respect to the operating table and it should be noted that patient orientation can vary throughout the procedure. 45 The Alignment Guide is unscrewed and replaced by the 28 mm Pusher provided while pressurisation and cup position are maintained throughout cement polymerisation (Figure 5). Figure 4 Once the cement is fully polymerised, the rim of the acetabulum is carefully cleared of all cement debris and the cup is covered with a clean swab to protect it during preparation of the femur. Figure 5 5 DePuy Synthes TRILOC Product Rationale and Surgical Technique

ORDERING INFORMATION Instruments Implants 9626-29-000 Acetabular Prep Drill L95470 Handle L95596 Inserter (two-piece) L95444 Trial 44 mm L95446 Trial 46 mm L95448 Trial 48 mm L95450 Trial 50 mm L95452 Trial 52 mm L95454 Trial 54 mm L95456 Trial 56 mm L95458 Trial 58 mm L95580 Neutral Alignment Guide L95578 Standard Alignment Guide L95582 28 mm Pusher L95594 32 mm Pusher 2440-00-546 QUICKSET Acetabular Grater Head 46 mm 2440-00-548 QUICKSET Acetabular Grater Head 48 mm 2440-00-550 QUICKSET Acetabular Grater Head 50 mm 2440-00-552 QUICKSET Acetabular Grater Head 52 mm 2440-00-554 QUICKSET Acetabular Grater Head 54 mm 2440-00-556 QUICKSET Acetabular Grater Head 56 mm 2440-00-558 QUICKSET Acetabular Grater Head 58 mm 2440-00-560 QUICKSET Acetabular Grater Head 60 mm 2440-00-562 QUICKSET Acetabular Grater Head 62 mm 2440-00-564 QUICKSET Acetabular Grater Head 64 mm 2440-00-565 QUICKSET Acetabular Grater Head 66 mm 9798-10-000 EZ Clean Grater Handle 12844 28 mm, Ø44 mm 12846 28 mm, Ø46 mm 12848 28 mm, Ø48 mm 12850 28 mm, Ø50 mm 12852 28 mm, Ø52 mm 12854 28 mm, Ø54 mm 12856 28 mm, Ø56 mm 12858 28 mm, Ø58 mm 13044 32 mm, Ø44 mm 13046 32 mm, Ø46 mm 13048 32 mm, Ø48 mm 13050 32 mm, Ø50 mm 13052 32 mm, Ø52 mm 13054 32 mm, Ø54 mm 13056 32 mm, Ø56 mm 13058 32 mm, Ø58 mm DePuy CMW Bone Cement 3095020 SMARTSET GHV Gentamicin 20g 3095040 SMARTSET GHV Gentamicin 40g 3025020 DePuy CMW 2 Gentamicin 20g 3025040 DePuy CMW 2 Gentamicin 40g 3092020 SMARTSET HV 20g 3092040 SMARTSET HV 40g 3322020 DePuy CMW 2 20g 3322040 DePuy CMW 2 40g Cement Accessories X-Ray Templates 2015-25-000 Pressuriser Handle Long 3206045 Acetabular Pressuriser 5 x 45 mm 3206052 Acetabular Pressuriser 5 x 52 mm 3206055 Acetabular Pressuriser 5 x 55 mm 3206060 Acetabular Pressuriser 5 x 60 mm 3206065 Acetabular Pressuriser 5 x 65 mm 5401-38-000 Open Mixing Bowl 5401-80-000 SMARTMIX Bowl 0612-80-000 X-Ray Templates TRILOC Product Rationale and Surgical Technique DePuy Synthes 6

References 1. Williams S, Leslie I, Isaac G, Jin Z, Ingham E, Fisher J. Tribology and wear of metal-on-metal hip prostheses: influence of cup angle and head position. J Bone Joint Surg. 2008;90A(Suppl 3):111-7. 2. Udomkiat P, Dorr LD, Wan Z. Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws: average ten-year follow-up. J Bone Joint Surg. 2002;84A:1195-200. 3. Schmalzried TP, Guttmann D, Grecula M, Amstutz H. The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis. J Bone Joint Surg.1994;76A:677-688. 4. Kennedy JG, Rogers WB, Soffee KE, et al. Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear and component migration. J Arthroplasty 1998;13:530-534. 5. Prudhommeaux F, Hamadouche M, Nevelos J, et al. Wear of alumina-on-alumina total hip arthroplasty at a mean 11-year followup. Clin Orthop Relat Res. 2000; 397:113. DePuy Orthopaedics EMEA is a trading division of DePuy International Limited. Registered Office: St. Anthony s Road, Leeds LS11 8DT, England Registered in England No. 3319712 DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN 46581 USA Tel: +1 (800) 366 8143 Fax: +1 (574) 267 7196 Summit Medical Ltd. Bourton On The Water Industrial Park Bourton On The Water Cheltenham Gloucestershire GL54 2HQ 0086 DePuy France S.A.S. 7 Allée Irène Joliot Curie 69800 Saint Priest France Tel: +33 (0)4 72 79 27 27 Fax: +33 (0)4 72 79 28 28 0459 DePuy International Ltd St Anthony s Road Leeds LS11 8DT England Tel: +44 (0)113 387 7800 Fax: +44 (0)113 387 7890 DePuy International Ltd Trading as DePuy CMW Cornford Road Blackpool FY4 4QQ Lancashire England Tel: + 44 (0)1253 765 167 Fax: + 44 (0)1253 697 431 DePuy Ireland Loughbeg Ringaskiddy Co. Cork Ireland Tel: + 353 21 4914 000 Fax: + 353 21 4914 199 Fax: +33 (0)4 72 79 28 28 0086 DePuy International Ltd. and DePuy Orthopaedics, Inc. 2013. All rights reserved. depuysynthes.com DPEM/ORT/1013/0003 0612-02-020 Issued: 11/13