Basics of Cervix Brachytherapy. William Small, Jr., MD Professor and Chairman Loyola University Chicago

Similar documents
ICRT รศ.พญ.เยาวล กษณ ชาญศ ลป

Interstitial Brachytherapy. Low dose rate brachytherapy. Brachytherapy alone cures some cervical cancer. Learning Objectives

Definitions. Brachytherapy in treatment of cancer. Implantation Techniques and Methods of Dose Specifications. Importance of Brachytherapy in GYN

Brachytherapy Planning and Quality Assurance

Brachytherapy Planning and Quality Assurance w Classical implant systems and modern computerized dosimetry w Most common clinical applications w


SYSTEMS IN BRACHYTHERAPY. Alfredo Polo MD, PhD Division of Human Health International Atomic Energy Agency

Basics of Cervix Cancer Brachytherapy

presenting Brachytherapy with focus on Gynecological Cancers

Pulsed Dose Rate for GYN Brachytherapy

INTRODUCTION TO BRACHYTHERAPY, HISTORY AND INDICATIONS. Christine Haie-Meder Brachytherapy Unit

EMBRACE- Studien Analysen und Perspektiven

Basic Concepts in Image Based Brachytherapy (GEC-ESTRO Target Concept & Contouring)

A Study on Dosimetry of Gynaecological Cancer and Quality Assurance of HDR Brachytherapy in BPKMCH, Nepal

Intracavitary + Interstitial Techniques Rationale

Brachytherapy an Overview

Regulatory Guidelines and Computational Methods for Safe Release of Radioactive Patients II. Brachytherapy

GYNECOLOGIC CANCER and RADIATION THERAPY. Jon Anders M.D. Radiation Oncology

MRI Guided GYN Brachytherapy: Clinical Considerations

Outline - MRI - CT - US. - Combinations of imaging modalities for treatment planning

Linking DVH-parameters to clinical outcome. Richard Pötter, Medical University of Vienna, General Hospital of Vienna, Austria

Dose-Volume Histogram Analysis in Point A-based Dose Prescription of High-dose-rate Brachytherapy for Cervical Carcinoma

Venezia Advanced Gynecological Applicator Reaching beyond

MR-Guided Brachytherapy

3D ANATOMY-BASED PLANNING OPTIMIZATION FOR HDR BRACHYTHERAPY OF CERVIX CANCER

Chapter 13: Brachytherapy: Physical and Clinical Aspects

The Evolution of RT Techniques for Gynaecological Cancers in a developing country context

Patterns of Care in Patients with Cervical Cancer:

Advances in Gynecologic Brachytherapy

The New ICRU/GEC ESTRO Report in Clinical Practice. Disclosures

BRACHYTHERAPY IN HORSES

Johannes C. Athanasios Dimopoulos

16 Primary Vaginal Cancer Alain Gerbaulet, Richard Pötter, Christine Haie-Meder

Basic Fundamentals & Tricks of the Trade for Intracavitary Radiotherapy for Cervix Cancer. Paula A. Berner, B.S., CMD, FAAMD

INTRODUCTION PATIENT. J. Radiat. Res., 52, (2011)

Does the apex optimization line matter for single-channel vaginal cylinder brachytherapy planning?

University of Alberta

Impact of brachytherapy applicators geometry on dose distribution in gynaecological cancer

Comparison of rectal and bladder ICRU point doses to the GEC ESTRO volumetric doses in Cervix cancer

PRINCESS MARGARET CANCER CENTRE CLINICAL PRACTICE GUIDELINES GYNECOLOGIC CANCER CERVIX

Course Directors: Teaching Staff: Guest Lecturers: Local Organiser: ESTRO coordinator: Melissa Vanderijst, project manager (BE)

Image based Brachytherapy- HDR applications in Gynecological Tumors

Locally advanced disease & challenges in management

Modern Interstitial GYN Brachytherapy. Conflicts: 8/3/2016. Modern Interstitial GYN Brachytherapy. 1. Use of MR

HDR Applicators and Dosimetry*

Course Directors: Teaching Staff: Guest Lecturers: Local Organiser: ESTRO coordinator: Melissa Vanderijst, project manager (BE)

Clinical Applications of Brachytherapy Radiobiology. Radiobiology is Essential

Radioactive sources in brachytherapy

Brachytherapy The use of radioactive sources in close proximity to the target area for radiotherapy

12 Physics and Clinical Aspects of Brachytherapy

Review of brachytherapy in

Three fraction high dose rate brachytherapy schedule for treatment of locally advanced uterine cervix cancer center:

CHAPTER : 1 INTRODUCTION 1.1 Carcinoma of the Cervix (Cervical Cancer)

Brachytherapy in Africa

The Future of Brachytherapy. Alex Rijnders Europe Hospitals Brussels, Belgium

GYN GEC-ESTRO/ICRU 89 Target Concept. Richard Pötter Medical University Vienna

Gyn Pre-planning: Intracavitary Insertion

Course Directors : Teaching Staff : Guest Lecturer: Local Organiser: ESTRO coordinators: Melissa Vanderijst and Marta Jayes, project managers (BEL)

Oral cavity cancer Post-operative treatment

INTRODUCTION. J. Radiat. Res., 53, (2012)

Radiotherapy & Cervical Cancer Dr Mary McCormack Consultant Clinical Oncologist University College Hospital, London,UK

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Treatment planning study of the 3D dosimetric differences between Co-60 and Ir-192 sources in high dose rate (HDR) brachytherapy for cervix cancer

Original Article ABSTRACT INTRODUCTION

Recent proceedings in Brachytherapy Physics

How ICD-10 Affects Radiation Oncology. Presented by, Lashelle Bolton CPC, COC, CPC-I, CPMA

Challenging Cases in Cervical Cancer: Parametrial Boosting. Beth Erickson, MD, FACR, FASTRO Medical College Wisconsin

Developments in Directional Brachytherapy William Y. Song, PhD, DABR

KEY WORDS: Carcinoma cervix, high-dose-rate brachytherapy, radiotherapy

Recent Advances and current status of radiotherapy for cervix cancer

Preliminary reports. Primoz Petric, MD, MSc, Robert Hudej, PhD, Maja Music, MD. Abstract. Introduction

Evaluation of Survival and Treatment Toxicity With High-Dose-Rate Brachytherapy With Cobalt 60 In Carcinoma of Cervix

2015 Radiology Coding Survival Guide

Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

JMSCR Vol 06 Issue 12 Page December 2018

Dosimetric comparison of interstitial brachytherapy with multi-channel vaginal cylinder plans in patients with vaginal tumors

Elekta: Emerging markets

Monte Carlo simulation of 192 Ir radioactive source in a phantom designed for brachytherapy dosimetry and source position evaluation.

Advances in Image-guided Brachytherapy

PROSTATE CANCER BRACHYTHERAPY. Kazi S. Manir MD,DNB,PDCR RMO cum Clinical Tutor Department of Radiotherapy R. G. Kar Medical College

MultiSource. for a higher standard in HDR brachytherapy.

Advancing Care Through Teamwork

Image guided brachytherapy in cervical cancer Clinical Aspects

Healthcare Professional Guide

EMBRACE I Data completeness Database dump

CT Guided Contouring: Challenges and Pitfalls

Index. T1 and T2-weighted images, 189

Gynecologic Vaginal Brachytherapy (Mostly Post-Op Endometrial)

Current Status of Accelerated Partial Breast Irradiation. Julia White MD Professor, Radiation Oncology

Original Date: June 2013 Page 1 of 7 Radiation Oncology Last Review Date: September Implementation Date: December 2014 Clinical Operations

ARROCase: Locally Advanced Endometrial Cancer

for the Degree of Master of Medicine in Radiation oncology WONDEMAGEGNHU TIGENEH MB. Ch. B, FCR (Onc) SA. Division of Radiation Oncology

University Cooperation Platform

International Journal of Science and Research (IJSR) ISSN (Online): Index Copernicus Value (2015): Impact Factor (2015): 6.

Image guided adaptive brachytherapy in patients with cervical cancer

Enterprise Interest None

DOSIMETRIC OPTIONS AND POSSIBILITIES OF PROSTATE LDR BRACHYTHERAPY WITH PERMANENT I-125 IMPLANTS

Radiation (ebt/hdr) for Non-Melanoma Skin Cancers (NMSCC) in the Dermatologist s Office: A Radiation Oncologist s (Generally Positive) Perspective

THE ROLE OF RADIATION THERAPY IN MANAGEMENT OF PANCREATIC ADENOCARCINOMA. TIMUR MITIN, MD, PhD

A B S T R A C T. 1. Introduction

Transcription:

Gynecologic Cancer InterGroup Cervix Cancer Research Network Basics of Cervix Brachytherapy William Small, Jr., MD Professor and Chairman Loyola University Chicago Cervix Cancer Education Symposium, January 2017, Mexico

Gynecologic Cancer InterGroup Cervix Cancer Research Network OBJECTIVES 1. Review the history of Brachytherapy in Cervical Cancer. 2.Review the need for Brachytherapy in modern radiation. 3.Discuss HDR Co-60 vs. Ir-192 4.Review Modern Image Guided Brachytherapy Cervix Cancer Education Symposium, January 2017, Mexico

Marie and Pierre Curie Antoine Henri Becquerel The discovery of radioactivity, 1896-1898

Applicators for intracavitary treatments Manchester / Fletcher: Tandem & Ovoids Stockholm: Tandem & Ring Institute Gustave Roussy: Mould technique

Summary Individualized Modern standardized Historical Parish Historical Paris Technique 1910-1920: Curie Institute, Paris, France Stockholm Manchester Fletcher Applicator: Rubber tandem not connected Cork colpostats (paraffin coated) no fixed geometry Stockholm Manchester & Fletcher Distance colpostats: not fixed 226 Ra preloading X mg of 226 Ra for Y hours Mould Typical application GEC ESTRO Handbook of Brachytherapy 5 days (120 h) 7000-8000 mgh

Summary Individualized Modern standardized Historical Paris Classical Stockholm method 1913-1914: Radiumhemmet, Stockholm, Sweden Stockholm Manchester Fletcher Applicator: Flat box (plate) Flexible tube Stockholm Manchester & Fletcher not connected 226 Ra preloading No fixed geometry Intrauterine tube: 30-90 mg Vaginal plate: 60-80 mg Unequal loading of uterine / vaginal 226 Ra Mould Typical treatment 2 3 applications (á 20-30 h) 7000 mgh

Summary Individualized Modern standardized Historical Paris Historical Manchester System 1938: Holt Radium Institute, Manchester, England Stockholm Manchester Fletcher Stockholm Manchester & Fletcher Mould

Summary Individualized Modern standardized Historical Historical Manchester System Related to historical Paris technique Paris Stockholm Manchester Fletcher Applicator: no fixed geometry Intrauterine tube 226 Ra preloading (mg): 15 22.5 22.5 3 cm (L) Vaginal ovoid Flange 10 10 15 10 20 20 20 2.5 cm (M) 2 cm (S) Stockholm 6 cm 4 cm 3.5 cm 17.5 17.5 Manchester & Fletcher Mould Spacer TYPICAL TREATMENT: 140 hours for 7500 R at point A (dose rate 53 R/h) Point A 2 cm 2 cm Meredith WJ, ed.. Radium dosage. The Manchester system. Edinburgh;1947. Given tumour volume A set of rules Geometry mg of 226 Ra Duration Certain point A dose

Summary Individualized Modern standardized Historical Paris Fletcher Suit Delclos Horiot Technique 1950 s: Fletcher Stockholm Manchester Fletcher Adjustable tandem length Variety of curvatures Stockholm Manchester & Fletcher Flange Cylindrical colpostats +/- tungsten shielding Clamp 1 cm 2 cm Mould Fixed geometry 2.5 cm 3 cm

Summary Individualized Modern standardized Historical Paris Modern Intracavitary Techniques Applicators: mimicking historical geometries Stockholm Manchester Fletcher Manchester / Fletcher style Common features: Stockholm style Uterine Tandem: various lengths, angles or curvatures Stockholm Manchester & Fletcher Ovoids, cylinders, rings various outer & source path diameters Clamp Mould 30 45 15 2 0 25 30 mm Source path Ф Outer Ф 26 38 30 42 34 mm 47 mm

Is There a Need for Brachytherapy with Modern External Beam Radiation? Cervix Cancer Education Symposium, January 2017, Mexico

Gynecologic Cancer InterGroup Cervix Cancer Research Network Methods Population-based, retrospective cohort study of 18 SEER registries Inclusion Criteria: Stage IB IVA cervical cancer treated between 1988 2009 with RT Exclusion Criteria: Rare histologies Treated with surgery History of other malignancy Han et al, Int J Rad Oncol Bio Phys, 2013

Gynecologic Cancer InterGroup Cervix Cancer Research Network Patient & Tumor Characteristics by Brachytherapy Use Cervix Cancer Education Symposium, January 2017, Mexico

Brachytherapy utilization rate (%) Gynecologic Cancer InterGroup Cervix Cancer Research Network Brachytherapy utilization rate in 18 SEER registries 100 80 60 40 20 0 Cervix Cancer Education Symposium, January 2017, Mexico

Gynecologic Cancer InterGroup Cervix Cancer Research Network Independent Predictors of Brachytherapy Use Younger age Married (vs not) Earlier year of diagnosis Earlier stage Certain SEER regions Cervix Cancer Education Symposium, January 2017, Mexico

Gynecologic Cancer InterGroup Cervix Cancer Research Network Cervix Cancer Education Symposium, January 2017, Mexico

Gynecologic Cancer InterGroup Cervix Cancer Research Network Cervix Cancer Education Symposium, January 2017, Mexico

Multivariable Cox Regression Characteristics Cancer-Specific Survival Overall Survival HR (95% CI) P HR (95% CI) P Brachytherapy No 1 (reference) 1 (reference) Yes 0.64 (0.57-0.71) <.001 0.66 (0.60-0.74) <.001 Stage IB2 1 (reference) 1 (reference) II 1.18 (0.93-1.49).17 1.16 (0.93-1.44).18 III 2.28 (1.80-2.88) <.001 2.14 (1.72-2.67) <.001 IVA 3.50 (2.49-4.92) <.001 3.08 (2.24-4.22) <.001 Histology SCC 1 (reference) 1 (reference) Adenocarcinoma 1.32 (1.10-1.60).004 1.28 (1.08-1.52).005 Other 1.26 (0.97-1.64).08 1.26 (0.98-1.60).07 Other significant factors: Age; Marital Status; Race; Ethnicity; Registry

Gynecologic Cancer InterGroup Cervix Cancer Research Network Conclusions Recent decline in brachytherapy utilization in the U.S. Brachytherapy use is independently associated with significantly higher CSS and OS. Brachytherapy should be implemented in all feasible cases. Cervix Cancer Education Symposium, January 2017, Mexico

Refaat et al. Am J Clin Oncol. 2014 Jan 30. [Epub ahead of print]

A) Intraoperative imaging at the time of first implant B) Isodose distribution with 2002 cgy delivered continuously to point A over 43.83 hours using Cs-137 for the first implant with a total activity of 124.38 mci. Refaat et al. Am J Clin Oncol. 2014 Jan 30. [Epub ahead of print]

129 eligible cervical cancer patients The median age was 46 years stages I, II, III, IV (29.5%, 48.1%, 17.8% and 4.6% respectively). The median follow up was 37 months (mean 58 ± 59, range 3 275). The 3-years OS, PFS, LRC, and DC were 75.9%, 71.6%, 84.7%, and 80.2%, respectively. The 5-years OS, PFS, LRC, and DC were 70.7%, 68.7%, 84.7%, and 78.3%, respectively. The 10-years OS, PFS, LRC, and DC were 68.7%, 62.3%, 82.5%, and 73.2%, respectively. Refaat et al. Am J Clin Oncol. 2014 Jan 30. [Epub ahead of print]

Refaat et al. Am J Clin Oncol. 2014 Jan 30. [Epub ahead of print]

Conclusion Standard LDR Brachytherapy cures significant percentage of patients although there is room for improvement. There is not insignificant long term toxicities.

Gynecologic Cancer InterGroup Cervix Cancer Research Network HDR - Sources CO60 vs IR192 Cervix Cancer Education Symposium, January 2017, Mexico

Gynecologic Cancer InterGroup Cervix Cancer Research Network More than 300 installed Systems in more than 50 Countries Most using Co60 sources Cervix Cancer Education Symposium, January 2017, Mexico

Gynecologic Cancer InterGroup Cervix Cancer Research Network Important parameter for a HDR source Doserate : must be in the HDR-Doserate range Biological effects Treatment time Dimension : as small as possible For interstitial and intraop treatment small applicators Dose - distribution : strong dose gradient high dose to target volume but low dose to OAR Cervix Cancer Education Symposium, January 2017, Mexico

Gynecologic Cancer InterGroup Cervix Cancer Research Network 0.9 C M o- in 6 i 0 atu S ri o ze u d rc C e o- ( 6 C 0 o S 0 o. u A r 8 ce 6) Ir-192 Source Ir-192 Source (Ir2.A85-2) 100.000 source transfers use for 5 years Co-60 Sources are not large anymore Cervix Cancer Education Symposium, January 2017, Mexico 25.000 source transfers use for 3,4 (5) month Co-60 source is suitable for all BT applications

Gynecologic Cancer InterGroup Cervix Cancer Research Network Source Specifications Cobalt-60 Iridium-192 ISO Classification 2919- C 65444 C 63333 1998 Half-life 5,27 years 73,8 days Physical-Chemical form solid, metal solid, metal Source activity 74 GBq ± 10% 370 GBq + 30%; -10% Outer dimensions of the source: Diameter Total length of the wire: 1 mm 2180 mm 0,9 mm 2180 mm Dimensions of active part Diameter: Length: Working life 0,5 mm 3,5 mm max 100.000 source transfers or 5 years 0,6 mm 3,5 mm max 25.000 source transfers or 4 months Cervix Cancer Education Symposium, January 2017, Mexico

Gynecologic Cancer InterGroup Cervix Cancer Research Network Physical Data The air kerma-rate-constant is almost three times higher for Co-60 than for Ir-192 Nuclid e _ E (MeV) T 1/2 (Ci/g) Γ (μgy m 2 GBq -1 h - 1) d 1/10 1) (lead) d 1/10 (concret e) air mean energy half-life specific activity kermarate constant tenth value layer tenth value layer Co-60 1.253 5,27a 330 309 4,8cm 32cm Ir-192 0.38 73,8d 450 108 1,2cm 23cm Co-60 vs. Ir- 192: factor 2.86

Gynecologic Cancer InterGroup Cervix Cancer Research Network Sample treatment time Ir-192 vs Co-60 Cervix cancer Fletcher Applicator Standard loading 5 Gy to Manchester A point IR192 (2 month) 22,8 mgy/h 207 GBq ~ 11 Min Co60 (1 years) 18,5 mgy/h 56,9 GBq ~ 11 Min Cervix Cancer Education Symposium, January 2017, Mexico

Gynecologic Cancer InterGroup Cervix Cancer Research Network Dose at the OAR even little bit lower for Co-60 than for Ir-192 Comparable dose distribution of Co-60 and Ir-192: Vaginal applicator Cervix Cancer Education Symposium, January 2017, Mexico

Gynecologic Cancer InterGroup Cervix Cancer Research Network Anisotropy Almost no difference between Co-60 and Ir-192 except the dip in direction of the source axis Cervix Cancer Education Symposium, January 2017, Mexico

Gynecologic Cancer InterGroup Cervix Cancer Research Network Isodoses: Co-60: green: 10Gy yellow: 7.5Gy red: 5Gy blue: 2.5Gy Ir-192: all white Cervix Cancer Education Symposium, January 2017, Mexico

Gynecologic Cancer InterGroup Cervix Cancer Research Network Number of source Ir-192 (every 4 months) Co-60 (every 5 years) 10 years 30 2 15 years 45 3 source exchanges using Co-60 mean: less expenses for sources less QC workload less logistic problems, less paperwork no loss of treatment days Cervix Cancer Education Symposium, January 2017, Mexico

Gynecologic Cancer InterGroup Cervix Cancer Research Network Cervix Cancer Education Symposium, January 2017, Mexico

Current State of The Art Brachytherapy

Gynecologic Cancer InterGroup Cervix Cancer Research Network Cervix Cancer Education Symposium, January 2017, Mexico

Gynecologic Cancer InterGroup Cervix Cancer Research Network Cervix Cancer Education Symposium, January 2017, Mexico

KBD

Gynecologic Cancer InterGroup Cervix Cancer Research Network Cervix Cancer Education Symposium, January 2017, Mexico

Gynecologic Cancer InterGroup Cervix Cancer Research Network Cervix Cancer Education Symposium, January 2017, Mexico

Gynecologic Cancer InterGroup Cervix Cancer Research Network Cervix Cancer Education Symposium, January 2017, Mexico

Gynecologic Cancer InterGroup Cervix Cancer Research Network Cervix Cancer Education Symposium, January 2017, Mexico

Summary Limitations modern intracavitary techniques Historical Paris Stockholm Manchester Fletcher Modern Intracavitary Techniques Covering the target volume with prescribed dose ( ) Standard loading target V Mid-coronal view

Summary Limitations modern intracavitary techniques Historical Paris Stockholm Manchester Fletcher Modern Intracavitary Techniques Covering the target volume with prescribed dose ( ) Modified loading target V Mid-coronal view

Summary Limitations modern intracavitary techniques Historical Paris Stockholm Manchester Fletcher Modern Intracavitary Techniques Covering the target volume with prescribed dose ( ) Modified loading Boost needed... EBRT? Interstitial BT? cold region target V Mid-coronal view

Gynecologic Cancer InterGroup Cervix Cancer Research Network Cervix Cancer Education Symposium, January 2017, Mexico

Gynecologic Cancer InterGroup Cervix Cancer Research Network Cervix Cancer Education Symposium, January 2017, Mexico

GEC-ESTRO Recommendations: Specific requirements for MRI T2-weighted images: High signal intensity After EBRT : intermediate signal intensity («grey zones») Image orientation: parallel orthogonal para-transversal para-coronal para-sagittal to applicator axes

Para coronal Para sagittal Specific requirements for MRI 52 Para transverse

Are we making any difference? Why to change from long-used practice to image guidance??!!

Conclusion Brachytherapy is critical in the treatment of locally advanced cervical cancer. LDR or HDR are reasonable choices. Modern brachytherapy includes MRI image guidance.