Measurement of spinal cord blood flow by an inhalation method and intraarterial injection of hydrogen gas

Similar documents
Identification and Selective Perfusion of the Spinal Cord-Feeding Arteries by Intrathecal po 2 Monitoring for Spinal Cord Protection

T ment of the descending thoracic or thoracoabdominal

Neurological Complications of TEVAR. Frank J Criado, MD. Union Memorial-MedStar Health Baltimore, MD USA

Postoperative risk factors for delayed neurologic deficit after thoracic and thoracoabdominal aortic aneurysm repair: A case-control study

Influence of segmental spinal cord perfusion on intrathecal oxygen tension during experimental thoracic aortic crossclamping

ORIGINAL ARTICLE. Systemic Temperature and Paralysis After Thoracoabdominal and Descending Aortic Operations

Acute dissections of the descending thoracic aorta (Debakey

Influence of segmental arteries, extent, and atriofemoral bypass on postoperative paraplegia after thoracoabdominal aortic operations

Hybrid Repair of a Complex Thoracoabdominal Aortic Aneurysm

Thoracoabdominal aortic aneurysms by definition traverse

Combination of Myogenic and Neurogenic Motor Evoked Potential Monitoring During Thoracoabdominal Aortic Surgery

Selective Visceral Perfusion during Thoracoabdominal Aortic Aneurysm Repair

H. J. Safit, M. P. Campbell, C. C. Miller III, D. C. Iliopoulos, A. Khoynezhad, G. V. Letsou and P. J. Asimacopoulos

The SPIDER-Graft for Thoracoabdominal Aortic Repair a feasability study in pigs

Protecting the brain and spinal cord in aortic arch surgery

Malperfusion Syndromes Type B Aortic Dissection with Malperfusion

SPINAL CORD ISCHEMIA AFTER THORACIC ANEURYSM REPAIR: RISK STRATIFICATION & PREVENTION DISCLOSURES. INDIVIDUAL None

Ascending Thoracic Aorta: Postsurgical CT Evaluation

Table I. Associated diseases

Management of Bone and Spinal Cord in Spinal Surgery.

Descending aorta replacement through median sternotomy

Influence of Perioperative Hemodynamics on Spinal Cord Ischemia in Thoracoabdominal Aortic Repair

Accepted Manuscript. Perioperative renal function and thoracoabdominal aneurysm repair: Where do we go from here? Leonard N. Girardi, M.D.

1000mg. 1 g/kg/hr g/kg/hr , 2003 X CT. 148 / 92mmHg 66 / SEP CSFP SEP. Tel:

The impact of diaphragm management on prolonged ventilator support after thoracoabdominal aortic repair

Daniela Branzan MD, Department of Vascular Surgery and Department of Interventional Angiology University Hospital Leipzig

Combined use of an epidural cooling catheter and systemic moderate hypothermia enhances spinal cord protection against ischemic injury in rabbits

11.1 The Aortic Arch General Anatomy of the Ascending Aorta and the Aortic Arch Surgical Anatomy of the Aorta

Descending Thoracic Aortic Aneurysm: Surgical Approach and Treatment Using the Adjuncts Cerebrospinal Fluid Drainage and Distal Aortic Perfusion

Intraoperative spinal cord monitoring (IOM) during surgery

BP and Heart Rate by Telemetry

Anterior Spinal Artery and Artery of Adamkiewicz Detected by Using Multi-Detector Row CT

POSTGRADUATE INSTITUTE OF MEDICINE UNIVERSITY OF COLOMBO. MD (ANAESTHESIOLOGY) FINAL EXAMINATION AUGUST 2011 Time : 1.00 p.m p.m.

Subclavian artery Stenting

clearing activity is produced and destroyed in the rat. Both the

Preoperative and operative predictors of delayed neurologic deficit following repair of thoracoabdominal aortic aneurysm

B myonephropathic metabolic syndrome MNMS 33 CT DeBakey IIIb MNMS

Management of Acute Aortic Syndromes. M. Grabenwoger, MD Dept. of Cardiovascular Surgery Hospital Hietzing, Vienna, Austria

Thoracoabdominal Aorta: Advances and Novel Therapies

CERVICAL PLEXUS BLOCK FOR CAROTID ENDARTERECTOMY FOLLOWED BY GENERAL ANESTHESIA FOR ABDOMINAL AORTIC SURGERY

ABERRANT RIGHT SUBCLAVIAN ARTERY AND CALCIFIED ANEURYSM OF. Jose Rubio-Alvarez, Juan Sierra-Quiroga, Belen Adrio Nazar and Javier Garcia Carro.

The ZnJEuence of Dextrose Administration on Neurologic Outcome after Temporary Spinal Cord Ischemia in the Rabbit

Evolving Strategy and Results of Spinal Cord Protection in Type I and II Thoracoabdominal Aortic Aneurysm Repair

How to manage the left subclavian and left vertebral artery during TEVAR

Dissection of descending aorta treated by stent-graft implantation in a patient with Marfan syndrome

Aggressive Resection/Reconstruction of the Aortic Arch in Type A Dissection

UPDATES IN INTRACRANIAL INTERVENTION Jordan Taylor DO Metro Health Neurology 2015

Aortic Arch/ Thoracoabdominal Aortic Replacement

INL No. A0083 Project Medtronic Thoracic patients guide Description Version 18

SANWICH TECHNIQUE TO REDUCE COMPLICATIONS WHEN TREATING BILATERAL INTERNAL ILIAC ARTERY

Antegrade Thoracic Stent Grafting during Repair of Acute Debakey I Dissection: Promotes Distal Aortic Remodeling and Reduces Late Open Re-operation

EVAR and TEVAR: Extending Their Use for Rupture and Traumatic Injury. Conflict of Interest. Hypotensive shock 5/5/2014. none

Neuromonitor-guided repair of thoracoabdominal aortic aneurysms

PTA 106 Unit 1 Lecture 3

Open surgical repair of thoracoabdominal aneurysms - the Massachusetts General Hospital experience

Spontaneous Recanalization after Complete Occlusion of the Common Carotid Artery with Subsequent Embolic Ischemic Stroke

Treatment of Thoracoabdominal Aneurysms Is there a need for custom-made devices?

Open fenestration for complicated acute aortic B dissection

Percutaneous Approaches to Aortic Disease in 2018

PhD in Bioengineering and Medical-Surgical Sciences

I N earlier experiments we demonstrated. Role of histamine in posttraumatic spinal cord hyperemia and the luxury perfusion syndrome

Case Report 1. CTA head. (c) Tele3D Advantage, LLC

Cardiopulmonary Bypass for Thoracic Aortic Aneurysm: A Report on 488 Cases

Blood Supply of the CNS

SAMPLE EDITION PELVIC AND LOWER EXTREMITY ARTERIES WITH ENDOVASCULAR REVASCULARIZATION. Cardiovascular Illustrations and Guidelines

Tracheo-innominate artery fistula (TIF) is an uncommon

MARKING RING VEIN GRAFT VALVE INSTRUMENTS. Hook, Valve. TFX SURGICAL SPECIALTIES Phone Toll Free: Fax:

A New Technique for Repeated Measurement of Cardiac Output During Cardiopulmonary Resuscitation

Vascular Disorders. Nervous System Disorders (Part B-1) Module 8 -Chapter 14. Cerebrovascular disease S/S 1/9/2013

Interesting Cases - A Case Report: Renal Cell Carcinoma With Tumor Mass In IVC And Heart. O Wenker, L Chaloupka, R Joswiak, D Thakar, C Wood, G Walsh

SEP Monitoring. Outline. Outline 1/22/2015. Development of SEPs Stimulation and recording techniques Predictive value of SEP Uses of SEP monitoring

No Disclosure. Aortic Dissection in Japan. This. The Challenge of Acute and Chronic Type B Aortic Dissections with Endovascular Aortic Repair

SELECTIVE ANTEGRADE TECHNIQUE OF CHOICE

Useful? Definition of High-risk? Pre-OP/Intra-OP/Post-OP? Complication vs Benefit? Mortality? Morbidity?

Development of a Branched LSA Endograft & Ascending Aorta Endograft

SEP Monitoring. Andres A Gonzalez, MD Director, Surgical Neurophysiology Keck Medical Center of USC University of Southern California

YOU MUST BRING GLOVES FOR THIS ACTIVITY

Thoracoabdominal aortic aneurysm

VESSELS: GROSS ANATOMY

Anatomical Study of Blood Supply to the Spinal Cord

Combined Endovascular and Surgical Repair of Thoracoabdominal Aortic Pathology: Hybrid TEVAR

Spinal cord injury has been a devastating complication

Thoracic aortic trauma A.T.O.ABDOOL-CARRIM ACADEMIC HEAD VASCULAR SURGERY DEPARTMENT OF SURGERY UNIVERSITY OF WITWATERSRAND

ANAESTHESIA EDY SUWARSO

Replacement of the thoracoabdominal aorta for extensive

The Petticoat Technique Managing Type B Dissection with both Early and Long Term Considerations

THE EFFECT OF ASCORBIC ACID ON RENAL FUNCTION IN DOGS WITH ISCHEMIA REPERFUSION INJURY

2. Need for serial arterial blood gas determinations. 2. Anticipation of the initiation of thrombolytic therapy

Paraplegia in endovascular repair of TAA and in TEVAR: Incidence, prevention and therapy. Johannes Lammer Medical University Vienna, Austria

Neurosurgical Techniques

SURGICAL PROCEDURE DESCRIPTIONS

Despite recent advances in operative techniques, anesthetic

Deliberate Renal Ischemia

Effects of myocardial infarction on catheter defibrillation threshold

Spinal cord ischemia in thoracoabdominal aneurysm surgery: monitoring and conditioning the spinal cord de Haan, P.

DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service

Circulation," Anrep and Starling(l) were unable to obtain evidence of

A prospective randomized study of cerebrospinal fluid drainage to prevent paraplegia after high-risk surgery on the thoracoabdominal aorta

University of Florida Department of Surgery. CardioThoracic Surgery VA Learning Objectives

Hemodynamic Monitoring and Circulatory Assist Devices

Transcription:

Measurement of spinal cord blood flow by an inhalation method and intraarterial injection of hydrogen gas Itoshi Harakawa, MD, Takashi Yano, MD, Tsunehisa Sakurai, MD, Naomichi Nishikimi, MD, and Yuji Nimura, MD, Nagoya, Japan Purpose: This study was performed to determine spinal cord blood flow using the H 2 clearance method. Methods: In 12 dogs we measured blood flow determined by hydrogen clearance techniques (BF) in both gray and white matter by spinal cord puncture, and compared the results with BF measured by a catheter inserted intrathecally to avoid spinal cord injury. We studied direct intraarterial and intravenous injection of hydrogen in addition to the inhalation method because hydrogen is an explosive gas. Results: BF measured intrathecally with catheters adherent to either the ventral or the dorsal funiculus did not differ significantly from that of the gray matter. BF measured with a catheter inserted into the epidural space was about one fourth of the BF measured intrathecally. Values measured by the intraarterial injection method did not differ significantly from those obtained by the inhalation method. Conclusions: BF measured with a catheter inserted intrathecally reflects blood flow in the gray matter of the spinal cord. Using intraarterial injection of He, BF was safely and accurately measured while avoiding the risk of explosion. (J Vasc Surg 1997;26:623-8.) The cause of paraplegia after aortic surgery is considered to be spinal cord ischemia. Presently, somatosensory evoked potentials and evoked spinal cord potentials have been used as indicators of spinal cord ischemia. However, false-positive and false-negative results have been reported 1,2 using these measures, and there is a delay between the occurrence of ischemia and a change in waveforms. Therefore, development of a more precise, reliable, and rapid method of monitoring spinal cord ischemia is desirable. To estimate spinal cord ischemia by the H 2 clearance method, we measured spinal cord blood flow in gray and white matters and compared these values with blood flow measured by a catheter that was inserted intrathecally to avoid spinal cord injury. The principle of the H 2 clearance method has been outlined previously. 3 As hydrogen gas accumulated in the tissue is washed out, the declining values are recorded as a clearance curve. The curve is replot- From the First Department of Surgery, Nagoya University School of Medicine. Reprint requests: Itoshi Harakawa, MD, First Department of Surgery, Nagoya University School of Medicine, 65 Tsurumaicho, Showa-ku, Nagoya 466, lapan. Copyright 1997 by The Society for Vascular Surgery and International Society for Cardiovascular Surgery, North American Chapter. 0741-5214/97/$5.00 + 0 24/1/84161 ted against time on semilogarithmic paper. The tissue blood flow is calculated using the formula 4 K = 69.3/(T/2). T/2 is half of the time in minutes for desaturation of hydrogen. Tissue blood flow is derived as an absolute value in ml,/min/100 g independently of its weight. The inhalation method is simple and usually is used as the standard hydrogen clearance technique, but because of the risk of explosion with hydrogen inhalation, we tested direct intraarterial and intravenous injection of hydrogen in addition to the inhalation method. To confirm the accuracy of a less injurious alternative to spinal cord puncture, we compared the blood flow measured with a catheter that was inserted intrathecally alongside the spinal cord with blood flow measured using spinal cord puncture. We tested two hypotheses: first, that intrathecal catheters would be as reliable as intraparenchymal electrodes in determining spinal cord blood flow by hydrogen clearance techniques; and second, that intraarterial and/or intravenous administration of hydrogen substituted for inhaled hydrogen would prove effective and have a lower risk of explosion. MATERIALS AND METHODS Twelve dogs (mean, 9.8 + 0.2 kg) were sedated with ketamine hydrochloride, intubated, and mechanically ventilated using halothane, oxygen, and 623

624 Harakawa et al. October 1997 Fig. I. Upper electrode is 2 mm in diameter. Tip of catheter is globular to avoid spinal cord injury, and platinum electrode for measuring H 2 clearance is placed 3 mm from tip. Lower electrode is 200 txm in diameter. Tip of catheter is sharp to minimize tissue injury by spinal cord puncture. Platinum electrode for measuring H 2 clearance is placed in tip. nitrous oxide. The electrocardiogram was monitored continuously. The animals were turned on their tight side. A catheter was placed through the femoral artery for distal aortic pressure monitoring. Dorsal or ventral laminectomy was performed from Thi2 to L1 to expose the dura mater. A platinum and stainless steel electrode 2 mm in diameter (Inter Medical Co., Nagoya, Japan) was inserted with a catheter into the epidural space. Then the dura mater was opened, and the catheter was inserted intrathecally toward the head until adherent to either the dorsal or ventral funiculus. A similar electrode 200 /xm in diameter was inserted into the gray or white matter by puncture under direct vision. Thoracotomy was performed, and a catheter was positioned in the descending aorta for proximal aortic pressure monitoring. An oblique abdominal incision was made, and the aortic bifurcation was exposed using an extraperitoneal approach. The tip of the 2 mm catheter was globular to avoid spinal cord injury; platinum electrodes for measuring H 2 clearance were placed 3 mm from the tip. The tip of the 200 b~m catheter was sharp to minimize tissue injury during spinal cord puncture (Fig. 1). Blood flow determined by hydrogen clearance techniques (BF), ph, and temperature were recorded before aortic cross-clamping. BF was measured both by the inhalation method and by the direct hydrogen bolus injection method. In the inhalation method, pure hydrogen gas was directly administered at 2 to 4 L/min for 5 to 20 breaths by puncture of the endotracheal tube with a 22-gauge needle. BF was monitored and recorded before, during, and after cross-clamping. Fig. 2 shows an example of BF recording before cross-clamping. The procedure required some 5 to 6 minutes to perform. The descending aorta was cross-clamped both immediately beyond the left subclavian artery and above the aortic bifurcation. Occlusion at the aortic bifurcation was performed by manual compression to reduce injury. This maneuver could be accomplished easily with the fingers given the small size and pliability of the canine aorta. To minimize spinal cord injury by aortic cross-clamping, aortic occlusion was maintained for only 2 minutes each time, which represented the minimum time required to ensure that the concentration of hydrogen remained below measurable limits. The procedure (BF recording before, during, and after clamping ) was performed three times on each dog. We sought to avoid irreversible ischemic change of the spinal cord from prolonged aortic cross-clamping, intending to ensure that after removing aortic occlusion BF would recover to the level before clamping. Indirect hydrogen bolus injection, the intravenous injection method (n = 2) was performed first. A bolus of saline solution (80 ml) saturated with hy-

Volume 26, Number 4 Harakawa et al. 625 Fig. 2. Upper figure shows example of BF recording before cross-clamping. BF is calculated from lower figure. T/2 is the half time in minutes for desaturation of hydrogen. The relationship of clearance to passage of time can be seen.

626 Harakawa et al. October 1997 O epidural space intrathecal space --~...... 1.7 43.4+ O. 1 ~ - - - - - ; Fig. 3. Spinal cord cross-section and BF of each region by inhalation method (ml/min/100 g). drogen at normal temperature was created after removing all air from one 500 ml package of saline solution, adding pure hydrogen gas, and then shaking. This mixture was injected into the femoral vein several times. The methods for aortic cross-clamping and measurement of BF were the same as those in the inhalation method. In the intraarterial injection method (n = 6), 50 ml of saline solution saturated with hydrogen by the same method was injected into the ascending aorta on each occasion. After completion of the experiment, the animals were ldlled with an intravenous bolus of KCI. Then the portion of spinal cord adherent to the 2 mm catheter and the portion punctured by the 200 ~m catheter were removed and placed in formalin for future microscopic study. The animals received humane care in compliance with the Guide for the Care and Use of Laboratory Animals published by the National Institutes of Health ( NIH Publication No. 86-23, revised 1985). Significance of the data was determined by the paired t test. Values were expressed as mean +_ SD. RESULTS Fig. 3 shows a cross-section of the spinal cord and BF of each region by the inhalation method. BF measured using an intrathecal catheter adherent to either the ventral or dorsal funiculus did not significantly differ from that of the gray matter (p > 0.05). BF measured by the catheter inserted into the epidural space was approximately one-fourth the BF measured by the intrathecal catheter. On intravenous injection, a clearance curve could not be obtained because the concentration of hydrogen remained below measurable limits. By the intraarterial injection method, measured values did not differ significantly from those obtained by the inhalation method (p > 0.05). In both the inhalation method and the intraarterial injection method, during clamping of the descending aorta BF measured by the catheters inserted intrathecally and in the gray matter remained below measurable limits. After declamping the aorta, BF values both intrathecally and in the gray matter recovered to the level before clamping (Fig. 4). The spinal cord specimens did not show any injury that resulted from catheter placement, such as bleeding or necrosis (Fig. 5). DISCUSSION Hydrogen, the most diffusible of all gases, is easily absorbed from the lung. The saturation volume of hydrogen per liter of water is 21 ml under standard conditions. Hydrogen is easily removed from the circulation via the lung. The hydrogen clearance method is well established, and many studies have used it to determine blood flow for various organs since Auldand et al.4 reviewed this method of blood flow measurement in 1964. Spinal cord blood flow has been measured using clearances, autoradiography, and other techniques. In the literature, 5 gray matter blood flow has been reported to be in the range of 40.6 to 63 ml/min/100 g, and white matter blood flow has been reported in the range of 10.3 to 21.7 ml/min/100 g. In our study, using the inhalation method, the gray matter blood flow was 45.9 -+ 6.6 ml/min/100 g, and the white matter blood flow was 25.2 + 7.0 ml/min/100 g. Many investigators have concluded that BF reflects the values for the small volume of tissue immediately surrounding the electrode. It has been proposed that the volume of tissue that BF reflects depends on the electrode diameter 6 and that BF reflects several cubic millimeters of tissue blood flow? BF measured by a catheter inserted intrathecally, adherent to either the ventral or dorsal funiculus, did not differ significantly from BF of gray matter. It may be argued that BF measured by intrathecal catheter reflected the blood flow in a marginal volume of white matter. However, because measurements showed the same changes as BF of gray matter during ischemic manipulation of the spinal cord, we conclude that BF measured by intrathecal catheter reflects the blood flow in the gray matter. Because catheters are placed into the epidural space to monitor evoked spinal cord potentials, an attempt was made to measure BF using a catheter inserted into the epidural space. As BF measured by the epidural catheter was approximately one-fourth

Volume 26, Number 4 Harakawa et al. 627 blood flow (mldmin/100g) 5O Aortic clamping and blood flow (inhalation method) 3G 2C before c \ lomin after.declamping 1C O 0 gray matter intrathecal (dorsal funiculus) blood flow (ml/min/100g).5o time of clamping Aortic clamping and blood flow (intra-arterial injection method) lime 40 30 before / ~min after declamping 20 10 / O O gray matter intrathecal (dorsal funiculus) time of clamping time Fig. 4. Aortic clamping and blood flow (inhalation method and intraarterial injection method). the BF measured by the intrathecal catheter, it did not reflect intraparenchymal blood flow and was judged unsuitable for monitoring'spinal cord ischemia. We compared the hydrogen inhalation method, which is simple and widely used but which is associated with a risk of explosion, with the intraarterial hydrogen injection method, and we confirmed that there was no significant difference between the two methods. Hydrogen has been injected into the carotid artery to calculate blood flow in the cerebral hemisphere of monkeys 7,8 and human beings 9 and has been injected into the aortic ostia to identify spinal radicular arteries. 1 Theoretically, the difference between the inhalation method and the intraarterial

628 Harakawa et al. October 1997 ing does not differ significantly from BF obtained before clamping, reattachment of segmental arteries may be unnecessary. Also, comparing BF after clamping with BF obtained before clamping may be useful in judging success of reattachment of segmental arteries. CONCLUSION Spinal cord blood flow measured in dogs showed that BF measured by an intrathecal catheter did not significantly differ from that of the gray matter of the spinal cord. By the intraarterial injection method, BF was safely measured and gave values not significantly different from those measured by the inhalation method. Therefore, measurement of BF with a catheter inserted intrathecaliy by the intraarterial injection method should be applicable to detection of spinal cord ischemia in aortic surgery. Fig. 5. Spinal cord specimen does not show injury caused by catheter, such as bleeding or necrosis. injection method is only the administration route of the hydrogen: in the inhalation method, hydrogen gas is absorbed from lung, passes through the arteries, and enters the tissues; in the intraarterial injection method, hydrogen is injected directly into the artery and then enters the tissues. Once hydrogen reaches the tissues, the principle of measuring blood flow by the hydrogen clearance technique is much the same by both methods. With the intraarterial injection method, BF can be safely measured. Our two hypotheses were supported by our results, except that intravenous administration of hydrogen did not produce detectable levels and therefore cannot be used for BF measurement. The present study should be expanded to trials in aortic surgcry to compare BF during aortic crossclamping with BF before clamping to assess need for reattaching segmental arteries. If BF during clamp- REFERENCES 1. Crawford ES, Mizrahi EM, Hess ICR, Coselli JS, Sail HJ, Patel VM. The impact of distal aortic perfusion and somatosensory evoked potential monitoring on prevention of paraplegia after aortic aneurysm operation. J Thorac Cardiovasc Surg 1988; 95:357-67. 2. Zomow MH, Grafe MR, Tybor C, Swenson MR. Preservation of evoked potential in a case of anterior spinal artery syndrome. Electroencephalogr Clin Neurophysiol 1990;77: 137-9. "3. Kerry SS, Schmidt CF. The determination of cerebral blood flow in man by the use of nitrous oxide in low concentration. Am J Physiol 1945;143:53-66. 4. Aukland K, Bower BF, Berliner RW. Measurement of local blood flow with hydrogen gas. Circ Res 1964;14:164-87. 5. Sandier AS, Tator CH. Review of the measurement of normal spinal cord blood flow. Brain Res 1976;118:181-98. 6. Young W. H2 clearance measurement of blood flow: a review of technique and polarographic principles. Stroke 1980;11: 552-64. 7. Shinohara Y, Meyer JS, I(itamura A, Toyoda M, Ryu T. Measurement of cerebral hemispheric blood flow by intracarotid injection of hydrogen gas. Circ Res 1969;25:735-45. 8. Meyer JS, Shinohara Y, Kanda T, Fukuuchi Y, Ericsson A, Rodprasert P. Hemispheric blood flow and metabolism in neurological disease: a note on the metabolic accompaniments of diaschisis. Trans Am Neurol Assoc 1969;94:303-7. 9. Meyer JS, Fukuuchi Y, Kanda T, Shimazu K, Hashi K. Regional cerebral blood flow measured by intracarotid injection of hydrogen. Neurology 1972;22:571-84. 10. Svensson LG, Patel VP, Coselli JS, Crawford ES. Preliminary report of localization of spinal cord blood supply by hydrogen during aortic operations. Ann Thorac Surg 1990;49:528-36. Submitted Mar. 18, 1997; accepted June 18, 1997.