Diastolic Augmentation with an External Pulsating Device To Treat Cardiogenic Shock

Similar documents
Section 6 Intra Aortic Balloon Pump

Hemodynamic Monitoring and Circulatory Assist Devices

Admission of patient CVICU and hemodynamic monitoring

Experience with Intraaortic Balloon Counterpulsation

THE journal OF EXTRA-CORPOREAL TECHNOLOGY ABSTRACT

Hemodynamic Monitoring

Counterpulsation. John N. Nanas, MD, PhD. Professor and Head, 3 rd Cardiology Dept, University of Athens, Athens, Greece

Images have been removed from the PowerPoint slides in this handout due to copyright restrictions.

Principles of intra-aortic balloon pump counterpulsation

Cardiac Assistance (Counterpulsation)

Mechanics of Cath Lab Support Devices

Interesting Cases - A Case Report: Renal Cell Carcinoma With Tumor Mass In IVC And Heart. O Wenker, L Chaloupka, R Joswiak, D Thakar, C Wood, G Walsh

ISPUB.COM. Intra Aortic Balloon Pump (IABP) Counterpulsation. P Oberwalder HISTORY PHYSIOLOGIC EFFECTS OF IABP THERAPY

Preclinical Studies of Abdominal Counterpulsation in CPR

Management of Cardiogenic Shock. Dr Stephen Pettit, Consultant Cardiologist

Mechanics of Cath Lab Support Devices

The use of Intra Aortic Baloon Pump in Patients undergoing Coronary Artery Bypass Grafting at the Aga Khan University Hospital, Karachi

Saphenous Vein Autograft Replacement

Cardiovascular Practice Quiz

Heart transplantation is the gold standard treatment for

Intraaortic Balloon Counterpulsation- Supportive Data for a Role in Cardiogenic Shock ( Be Still My Friend )

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

Understanding the Cardiopulmonary Bypass Machine and Its Tubing

Rhondalyn C. McLean. 2 ND YEAR RESEARCH ELECTIVE RESIDENT S JOURNAL Volume VII, A. Study Purpose and Rationale

Complications of Acute Myocardial Infarction

Cardiac Emergencies. Jim Bennett Paramedic and Clinical Education Coordinator American Medical Response Spokane, Washington

Epidemiology of Heart Failure in Adults

IABP Timing & Fidelity. Pocket Reference Guide

AORTIC GRAFT INFECTION

Ventricular Assisting Devices in the Cathlab. Unrestricted

Experience with counterpulsation in

Emergency surgery in acute coronary syndrome

Technique. Technique. Technique. Monitoring 1. Local anesthetic? Aseptic technique Hyper-extend (if radial)

CATCH A WAVE.. INTRODUCTION NONINVASIVE HEMODYNAMIC MONITORING 4/12/2018

CLINICAL SUPPORT SERVICES DEVELOPING AN IABP PRECEPTOR STRATEGY

The Role of Mechanical Circulatory Support in Cardiogenic Shock: When to Utilize

CVICU EXAM. Mrs. Jennings is a 71-year-old post-op CABG x5 with an IABP in her left femoral artery

University of Florida Department of Surgery. CardioThoracic Surgery VA Learning Objectives

Critical Care Nursing Program August to November, 2015 Full-time Lesson A13 Pumping and Perfusion III Basic Hemodynamic Monitoring

-Cardiogenic: shock state resulting from impairment or failure of myocardium

Echocardiography as a diagnostic and management tool in medical emergencies

Can be felt where an artery passes near the skin surface and over a

Acute arterial embolism

Extra Corporeal Life Support for Acute Heart failure

To ECMO Or Not To ECMO Challenges of venous arterial ECMO. Dr Emily Granger St Vincent s Hospital Darlinghurst NSW

Useful? Definition of High-risk? Pre-OP/Intra-OP/Post-OP? Complication vs Benefit? Mortality? Morbidity?

Circulatory Support: From IABP to LVAD

Cardiac anaesthesia. Simon May

Mechanical Support in the Failing Fontan-Kreutzer

Chapter 14. Cardiovascular Emergencies

CAE Healthcare Human Patient Simulator (HPS)

Aortic Dissection Causes of Death

Dr. Rami M. Adil Al-Hayali Assistant Professor in Medicine

MR Advance Techniques. Cardiac Imaging. Class IV

Mechanical Cardiac Support in Acute Heart Failure. Michael Felker, MD, MHS Associate Professor of Medicine Director of Heart Failure Research

Cardiovascular Nursing Practice: A Comprehensive Resource Manual and Study Guide for Clinical Nurses 2 nd Edition

Adult Echocardiography Examination Content Outline

Transcatheter closure of right coronary artery fistula to the right ventricle

From Recovery to Transplant: One Patient's Journey

Chapter 14 Cardiovascular Emergencies Cardiovascular Emergencies Cardiovascular disease has been leading killer of Americans since.

2.02 Understand the functions and disorders of the circulatory system

Acute heart failure: ECMO Cardiology & Vascular Medicine 2012

DECLARATION OF CONFLICT OF INTEREST

Competency Title: Caring for a patient with an arterial line

Cardiovascular System

ECLS as Bridge to Transplant

Intra-operative Effects of Cardiac Surgery Influence on Post-operative care. Richard A Perryman

Rationale for Prophylactic Support During Percutaneous Coronary Intervention

Understanding the Pediatric Ventricular Assist Device

Airway Management in a Patient with Klippel-Feil Syndrome Using Extracorporeal Membrane Oxygenator

A case of post myocardial infarction ventricular septal rupture CHRISTOFOROS KOBOROZOS, MD

Cath Lab Essentials : LV Assist Devices for Hemodynamic Support (IABP, Impella, Tandem Heart, ECMO)

Relax and Learn At the Farm 2012

for Right Ventricular Failure: 11. Clinical Experience

EMT. Chapter 14 Review

CHRONIC HEART FAILURE : WHAT ELSE COULD WE OFFER TO OUR PATIENTS? Cardiac Rehabilitation Society of Thailand

Lecture 2: Clinical anatomy of thoracic cage and cavity II

WHILE it is generally agreed that elevation

Peripheral and Cardiology Coder 2018

Lab 16. The Cardiovascular System Heart and Blood Vessels. Laboratory Objectives

Distal Coronary Artery Dissection Following Percutaneous Transluminal Coronary Angioplasty

CSC Review Course: Intra Aortic Balloon Pump (IABP) Paula M Davis ARNP, MSN, CCRN-CSC

Ultrasound-enhanced, catheter-directed thrombolysis for pulmonary embolism

Facing Coronary Artery Bypass Surgery? Learn about minimally invasive da Vinci Surgery

CARDIOGENIC SHOCK. Antonio Pesenti. Università degli Studi di Milano Bicocca Azienda Ospedaliera San Gerardo Monza (MI)

Perfusion for Repair of Aneurysms of the Transverse Aortic Arch

BACHELOR OF SCIENCE IN CARDIO VASCULAR TECHNOLOGY

Assist Devices in STEMI- Intra-aortic Balloon Pump

Cardiothoracic Fellow Expectations Division of Cardiac Anesthesia, Beth Israel Deaconess Medical Center

Chapter 16 Cardiovascular Emergencies Cardiovascular Emergencies Cardiovascular disease has been leading killer of Americans since 1900.

AORTIC DISSECTIONS Current Management. TOMAS D. MARTIN, MD, LAT Professor, TCV Surgery Director UF Health Aortic Disease Center University of Florida

Acute dissections of the descending thoracic aorta (Debakey

SHOCK AETIOLOGY OF SHOCK (1) Inadequate circulating blood volume ) Loss of Autonomic control of the vasculature (3) Impaired cardiac function

Cardiovascular Disorders. Heart Disorders. Diagnostic Tests for CV Function. Bio 375. Pathophysiology

Patient guide: pfm Nit-Occlud PDA coil occlusion system. Catheter occlusion of. Patent Ductus Arteriosus. with the

2. Need for serial arterial blood gas determinations. 2. Anticipation of the initiation of thrombolytic therapy

EACTS Adult Cardiac Database

Peripheral Arterial Disease: A Practical Approach

Protocol Identifier Subject Identifier Visit Description. [Y] Yes [N] No. [Y] Yes [N] N. If Yes, admission date and time: Day Month Year

L: Cardiovascular. Saskatchewan Association of Licensed Practical Nurses, Competency Profile for LPNs, 3rd Ed. 107

Transcription:

Diastolic Augmentation with an External Pulsating Device To Treat Cardiogenic Shock Nickolas Trubov, B.Sc., C.C.P. and Steven J. Phillips, M.D. Mercy Hospital, Des Moines, Iowa 50314 ABSTRACT An 80 cc stroke volume pulsatile assist device (PAD) was modified and used in place of an intra-aortic balloon for diastolic augmentation when passage of the balloon proved impossible due to aorto-femoral obstruction. The PAD was attached via the usual I 0 mm graft sutured end-to-side to the patient's left common femoral artery. Systemic heparinization prevented coagulation for 72 hours of PAD support after which time the patient had recovered and was discharged. Metabolic blood pressure was augmented 20-30 mm Hg and CVP reduced from 21 to 9 mm Hg. Pulmonary artery wedge pressure was reduced from 26 to 12 mg Hg and normal urine output was restored. Plasma free hemoglobin ranged from 5-41 mg% and platelet count from 92,000 to 188,000. No complications occurred. Timing was performed in the same manner as in surgery when the PAD is used in conjunction with the pump-oxygenator, and similar precautions were taken. The PAD appears to be an effective alternative counterpulsation in patients suffering from obstructive arteriosclerotic disease precluding the insertion of a balloon catheter. Intra-aortic balloon pumping is an accepted mode of therapy for treatment of complicated myocardial infarction. 1 2 Some patients who would benefit from intra-aortic balloon pumping cannot have the procedure applied via the femoral artery because of severe arteriosclerotic occlusive disease. This can prevent passage of the balloon or result in complications of insertion. 3-5 A small group of patients in which intra-aortic balloon pump can be applied, develop varying degrees of ischemic neuropathy in the leg in which the balloon was inserted, because of subliminal occlusion by the balloon catheter of the femoral artery, reducing flow through that leg. Here we describe a patient in which an intra-aortic balloon could not be inserted and a Pulsatile Assist Device (PAD )* was utilized for diastolic augmentation.6 7 CASE REPORT A 69-year-old man was referred for intra-aortic balloon pumping for treatment of cardiogenic shock secondary to myocardial infarction. The patient had sustained an acute inferior wall myocardial infarction 16 hours earlier. Eight hours earlier he developed multiple ventricular arrhythmias, hypotension, and required catecholamine support to maintain adequate perfusion pressure. He continued to deteriorate and was transferred * Registered Trademark of Datascope Corporation, Paramus, New Jersey. From the Section of Cardiovascular Medicine and Surgery, Mercy Hospital, Des Moines, Iowa 50314-Reprint requests to: Nickolas Trubov, 6124 Downey N. E. Albuquerque, New Mexico 87109. This paper was supported by a grant from the Dr. Sidney Meyer Zeff Cardiac Research Foundation. VOLUME II, NUMBER 2, 1979 61

fxternal PULSATING ( ATTACHED TO BALLOON CONSOLE ) Figure 1. Showing pulsatile assist device in position for long term counterpulsation. to Mercy Hospital, Des Moines, Iowa, for consideration of intra-aortic balloon pumping. Admission vital signs and physical examination revealed: blood pressure maintained at 70 mm Hg systolic by a norepinephrine drip, pulse rate was 120 and regular, CVP 21 mm Hg and PA wedge 26 mm Hg. He had had no urine output for the past 7 hours. He was responsive but was very somnolent and confused. His skin was cold and clammy and his extremities cold and mottled. His neck veins were distended to the angle of the jaw at 30 degrees. Chest auscultation revealed bilateral rales throughout and his heart sounds were very distant and could not be evaluated. His abdomen was soft with no masses or 62 THE JOURNAL OF EXTRA-CORPOREAL TECHNOLOGY

PAD OFF PAD ON ECG Radial Artery Pressure 50 25 Brachial Artery Doppler 0 Figure 2. Pulsatile assist device (off-on) providing femoral arterial diastolic augmentation in a patient in cardiogenic shock. organomegaly. His femoral pulses were palpable bilaterally, but his pedal and radial pulses could not be felt. The patient was admitted to the coronary care unit where preparation for intra-aortic balloon pump insertion was made. Under sterile conditions, utilizing local anesthesia, a left femoral cutdown was carried out. The common femoral artery above the profunda was isolated with tapes and incised. A 37 cc single chambered intra-aortic balloon** was inserted but could not be passed beyond the level of what was felt to be the aortic bifurcation. Multiple attempts at passage of guide wires and dilators were made, but were unsuccessful. A pulsatile assist device (Figure I) was prepared as follows: The corporeal connecting tubing of the PAD was clamped. The PAD and tubing were suspended vertically from an I.V. pole and filled with heparinized saline thereby removing all air from the system. The tubing just distal to the PAD was clamped which created a closed-ended pumping chamber with an 80 cc stroke volume. The patient received a heparinizing dose of 300 units/kg. Heparinization was maintained at 3000 units/hr. by continuous infusion. A I 0 mm low porosity dacron graft was sutured end-to-side to the common femoral artery. The graft was tunneled out through a separate stab wound in the skin lateral to the arteriotomy incision. A 26 French Datascope Corporation, Paramus, New Jersey. VOLUME II, NUMBER 2, 1979 63

arterial perfusion cannula*** was then inserted into the lumen of the graft and positioned approximately 1 em from the arteriotomy. The graft was then tied to the body of the cannula to prevent leakage. The cannula was filled with blood to remove air and connected to the PAD tubing. Air was then removed from the chamber of the PAD by removing the distal clamp and re-filling it with normal saline. PAD support was then initiated. Excellent diastolic augmentation was achieved as indicated by the radial arterial pressure tracing. In order to more accurately time the device, a brachial artery doppler wave form was utilized to define the dicrotic notch. (Figure 2) Over the next 24 hours, the patient's pulmonary artery wedge and central venous pressure normalized. The urine output increased, blood pressure stabilized, catecholamines were weaned and the peripheral signs of shock abated. After 72 hours of PAD support, hemodynamic stabilization occurred and the PAD was removed. The continuous heparin infusion was regulated by keeping the partial thromboplastin time at 30 minutes. During the period of PAD support no overt hematologic deficits were noted. The platelet count ranged between 92,000 and 188,000 and averaged 14 7,000. The highest free hemoglobin which occurred after 6 hours of PAD support was 41 mg %. DISCUSSION Intra-aortic balloon pumping continues to be our first choice of therapy for patients with complications of myocardial infarction. 1 Alternates to intra-aortic balloon pumping, though numerous, have not proven efficacious for the treatment of left ventricular power failure and have not gained wide clinical application. Such assist devices as arterial counterpulsator, body acceleration synchronous with the heart beat (BASH), left heart bypass, whole body counterpulsation, 8-12 etc., have been investigated experimentally and applied clinically but have not gained popularity for a variety of reasons. The PAD, a device described by Bregman, 7 et al., was designed to convert the continuous flow of cardiopulmonary bypass into pulsatile flow. It can also be utilized intra-operatively for diastolic augmentation prior to, during weaning, and following cardiopulmonary bypass. This device was modified and applied successfully in a patient in cardiogenic shock in which an intraaortic balloon could not be inserted. Though we were concerned about the possibility of retrograde aortic dissection with this device, no clinical complications were noted due to the application of the PAD in the manner described. The PAD appears to be safe and efficacious when applied in a patient in whom an intra-aortic balloon pump can not be safely inserted. REFERENCES 1. Kantrowitz, A., Tjonneland, S., Freed, P. S., Phillips, S. J., Butner, A. N., and Sherman, J. L., Jr.: Initial Clinical Experience With Intra-aortic Balloon Pumping In Cardiogenic Shock, JAMA 203:113, 1968. 2. Kantrowitz, A., Phillips, S. J., Butner, A. N., Tjonneland, G. S., and Hailer, J.D.: Technique of Femoral Artery Cannulation for Phase Shift Balloon Pumping, J. Thorac. Cardiovasc. Surg. 56:219, 1968. 3. Bregman, D., Bolooki, H., and Maim, J. F.: A Simple Method to Facilitate Difficult Intra-aortic Balloon Counterpulsation, Ann. Thorac. Surg. 15:636, 1973. 4. Lamberti, J. J., Cohn, L. H., and Collins, J. J. Jr.: Iliac Artery Cannulation for Intra-AOrtic Balloon Counterpulsation, Ann. Thorac. Surg. 67:976, 1974. 5. Phillips, S. J. and Zeff, R. H.: Balloon Insertion via Ascending Aorta, Ann. Thorac, Surg., 20:376, 1975. 6. Bergman, D., et al: Counterpulsation With A New Pulsatile Assist Device (PAD) in Open-Heart Surgery, Med. lnst., 10:232, 1976. U.S. Catheter Corporation. 64 THE JOURNAL OF EXTRA-CORPOREAL TECHNOLOGY

7. Kaplitt, M. J. and Tamari, Y.: Clinical Experience With the Tamari-Kaplitt Pulsator: A New Device to Create Pulsatile Flow or Counterpulsation During Open-Heart Surgery, Amer. Golf. Cardia/., Las Vegas, March, 1977. 8. Cooper, T. and Dempsey, P. J.: Assisted Circulation, Mod. Cone. Cardiovasc. Dis., 1.37:95, 1968, 11.37:101, 1968. 9. Amtzenius, A. C., Koops, J., and Hungenholtz, P. G.: Cardiovascular Responses in Piglets to Body Acceleration Given Synchronously with the Heartbeat, Circulation, 40:Suppl. 3, 38, 1969 (abs.) 10. Zwart, H. H., Kralios, A. C., Kwan-Get, C. S., Backman, D. K., Foote, J. L., Andrade, J. D. and Kolff, W. L.: Transarterial Closed Chest Left Ventricular Bypass for Desperate Heart Failure, J.A.A.M.I., 5:44, 1971. 11. Laird, J.D., Arntzenius, A. C.: The Effect of Body Acceleration Synchronous with the Heartbeat (BASH) or Aortic Root Pressures-An Inquiry to the Physical Basis, Trans. Amer. Soc. Artif. Int. Organs, 18:28, 1972. 14. Bregman, David: Mechanical Support Of The Failing Heart, Current Problems in Surg., 13:12 Dec., 1976. VOLUME II, NUMBER 2, 1979 65