Kit Assembly. Enhanced Simplicity OPERATIONAL BENEFITS. Automatic venous chamber adjustment. User friendly interface

Similar documents
UNDERSTANDING THE CRRT MACHINE

Dialysis System DBB-07

Prismaflex. Trusted. Versatile. Reliable. Making Possible Personal.

Can We Achieve Precision Solute Control with CRRT?

Citrate Anticoagulation

CONTINUOUS RENAL REPLACEMENT THERAPY (CRRT)

ST. DOMINIC-JACKSON MEMORIAL HOSPITAL JACKSON, MISSISSIPPI. CONTINUOUS RENAL REPLACEMENT THERAPY (CRRT) HEPARIN ANTICOAGULATION Page 1 of 5

Can We Achieve Precision Solute Control with CRRT?

Active UMMC Protocols

higher dose with progress in technical equipment. Continuous Dialysis: Dose and Antikoagulation. prescribed and delivered

CRRT Fundamentals Pre- and Post- Test. AKI & CRRT Conference 2018

Volumetric Infusion Pumps - Delivering Volume with Accuracy

oxiris A single CRRT set with multiple benefits for managing critically ill patients with AKI Adsorption of inflammatory mediators

Wales Critical Care & Trauma Network (North) CITRATE GUIDELINES (Approved May 2015)

MEDICAL EQUIPMENT II HEMODIALYSIS

Volumetric Infusion Pumps INFUSIONMANAGEMENT

Session 1: Circuit, Anticoagulation and Monitoring. Ashita Tolwani, MD, MSc Noel Oabel, BSN, RN, CNN 2019

CRRT for the Experience User 1. Claudio Ronco, M.D. David Selewski, M.D. Rolando Claure-Del Granado, M.D. AKI & CRRT Conference March, 2018

CRRT Interactive Hyperkalemia Cases AKI & CRRT conference 2018

CRRT Interactive Hyperkalemia Cases AKI & CRRT conference 2018

CRRT Fundamentals Pre-Test. AKI & CRRT 2017 Practice Based Learning in CRRT

404FM.2 CONTINUOUS RENAL REPLACEMENT THERAPY (CRRT) USING CITRATE Target Audience: Hospital only ICU. (Based on Gambro and Kalmar Hospital protocols)

MODALITIES of Renal Replacement Therapy in AKI

ECMO & Renal Failure Epidemeology Renal failure & effect on out come

Prolonged Dialysis: 24-hr SLED Is It CRRT? Balazs Szamosfalvi, MD

UAB CRRT Primer Ashita Tolwani, MD, MSc University of Alabama at Birmingham

Regional Citrate Anticoagulation for RRTs in Critically Ill Patients with AKI

The ACIST CVi Contrast Delivery System. Simplifying Contrast Injection. Bracco Group

Admission Day 2 Na Potassium Cl Bicarb BUN Cr Hb Hct platelets

Recent advances in CRRT

Continuous Renal Replacement Technology: From Adaptive Devices to Flexible Multipurpose Machines

AK 200 S AK 200 ULTRA S. A better way to better care

BPG 03: Continuous Renal Replacement Therapy (CRRT)

Drivers have GPS. Dialysis Patients have. Making possible personal.

Stefano Romagnoli, M.D., Ph.D.

CRRT: The Technical Questions Modality & Dose. Ashita J. Tolwani, MD, MSc University of Alabama at Birmingham 2018

ASCO Power Control Systems Overview

Operation-Fluids-Electrolytes-Acid Base COMPLICATIONS OF DIALYSIS 2

NEW! KIBION DYNAMIC 13 C BREATH TEST ANALYSER. Rapid and reliable diagnosis of Helicobacter pylori infections

NEUROSURGERY LiquoGuard

Managing Acid Base and Electrolyte Disturbances with RRT

Implementing therapy-delivery, dose adjustments and fluid balance. Eileen Lischer MA, BSN, RN, CNN University of California San Diego March 6, 2018

Metabolismo del citrato nei pazienti critici. Filippo MARIANO Dipartimento di Area Medica, SCDO di Nefrologia e Dialisi Ospedale CTO, Torino

RENAL FAILURE IN ICU. Jo-Ann Vosloo Department Critical Care SBAH

CRRT Procedures. and Guidelines. CRRT: Guidelines

Monitoring Equipment. Blood Pressure Monitor Upper Arm Type: Image (Image not to scale)

Veterinary Infusion Solutions

Technical Data Sheet SONOFLOW CO.55 V1.0

With extended functionality the sensors are also applicable for the detection of air bubbles.

Renal replacement therapy in Pediatric Acute Kidney Injury

IV Link Staff. Infection Prevention & Control A Learning Package for IV Link Staff

Photopheresis Technical Challenges. Lindsay Palomino, BSN RN HP May 6, 2016

THE FLOCARE RANGE OF ENTERAL FEEDING PUMPS, TUBES AND ACCESSORIES

PICANet Renal Dataset supplement Renal Daily Interventions

Product Catalog. EXCOR Pediatric The Ventricular Assist Device for Children

BLOOD IS COMPLEX ANALYZING IT SHOULDN T BE DxH 500 * *Not available for sale in the U.S.

Continuous Renal Replacement Therapy in PICU: explanation/definitions/rationale/background

Nurse-Pharmacist Collaboration in the Delivery of Continuous Renal Replacement Therapy

SCIP-Inf-10. Pediatric Warming Solutions. Complete. Pediatric Warming

Haemodialysis Machines H/S Visually the best dialysis results

BC380. The New Standard in Body Composition Analysis BODY COMPOSITION ANALYZER

Xperius Ultrasound System Responsive Advanced Simple NEW

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

Chapter 8 ADMINISTRATION OF BLOOD COMPONENTS

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0

Continuous Renal Replacement Therapy. Gregory M. Susla, Pharm.D., F.C.C.M. Associate Director, Medical Information MedImmune, LLC Gaithersburg, MD

Practice Based Learning in CRRT: The Science and the Art Pediatric Session. David Askenazi Theresa Mottes Scott Sutherland

Clinical Application of CRRT for Infants and Children

Designed with your patients lives in mind

Continuous Renal Replacement Therapy

Splitting of the characteristic K-alpha doublet radiation of molybdenum (Item No.: P )

PICANet Custom Audit Definitions Renal Dataset

microprocessor controlled eddy current brake Load / accuracy Watt, speed independent / according to DIN VDE

TREATMENT SAFETY AND EFFECTIVENESS CONTROL OF MODERN DIALYSIS MACHINES

P900 enteral syringepump

QUANTUM. Body Composition Scale. 396lb x 0.2lb 180kg x 0.1kg

PRODUCT DATA SHEET DIABETES CARE SMART FOR SELF-TESTING AND POINT-OF-CARE-TESTING OF WHOLE BLOOD GLUCOSE

The Portable Performance

Therapeutic Apheresis Performed in Tandem with Dialysis and Left Ventricular Assist Devices

Oral surgery and implantology. Easy and flexible. NEW. Respects your needs. Today and tomorrow.

CRRT: QUALITY MANAGEMENT SYSTEMS

NEGATIVE PRESURE WOUND THERAPY PROGRAM

ANTIBIOTIC DOSE AND DOSE INTERVALS IN RRT and ECMO

Large RCT s s in RRT : What can be learnt for nursing?

CyBio Felix Your Automated Application Starts Here

Karen Mak R.N. (Team Leader) Renal Dialysis Centre Hong Kong Sanatorium & Hospital

Multi-Therapy Smart Infusion for Home Care

James Beck ECS 8 November 2014 Citrate anticoagulation for continuous renal replacement therapy

H5N1 real- time Reverse Transcription Polymerase Chain Reaction (RT-PCR) assay

Gambro Renal Products Technical Assistance Services

Dr FuelCell Load Measurement Box

Medtronic MiniMed Insulin Infusion Pumps

Advancing Lives and the Delivery of Health Care. The High-Flow Port Designed for Apheresis

Improving quality of resuscitation. Defibrillators TEC-5600 series

Dosimeter Setting Device System NRZ

Haemodialysis. 4008S Visually the best dialysis results

Chapter 8 Online Hemodiafiltration by Fresenius Medical Care

PRP-100-GB. Instruction Manual

CRRT Fundamentals Pre- and Post- Test Answers. AKI & CRRT 2017 Practice Based Learning in CRRT

Dosimeter Setting Device

Transcription:

System for CRRT

Kit Assembly Enhanced Simplicity User friendly interface Flexible AcuSmart touch screen can be turned 180 degrees with up to 100 degrees of tilt in order to ensure visibility from various angles at the patient s bedside. OPERATIONAL BENEFITS A reliable and efficient device is essential for the demands of a modern Intensive Care Unit in supporting both doctors and nurses to provide the best possible care of the patient. User interface The screen design focuses on the most important parameters with distinct color coding, providing clear information at a glance. Automatic venous chamber adjustment Venous chamber fluid level changes lead to frequent manual adjustment of the fluid level. AcuSmart is equipped with an automatic adjustment function of the venous chamber which avoids timeconsuming manual adjustments and venous chamber related reatment interruptions.

AcuSmart has been developed together with Key Opinion Leaders from the CRRT speciality field in order to facilitate their daily tasks and to minimize their workload. Less trouble shooting Smart bag alarm AcuSmart only alarms if the fluid bags move for more than 5 seconds. Alarms caused by checking the fluid bags or movement of AcuSmart are therefore minimised and user interventions are reduced. Long maintenance intervals 15 Litres of fresh fluids can be connected to AcuSmart which allow, for longer intervals between bag changes: With an average flow rate of 1.5 l/hr AcuSmart can run for 10 hours without a bag change. Automatic blood flow rate control AcuSmart automatically adapts the blood flow rate to the arterial pressure. This ensures an accurate blood pump flow rate for the duration of the treatment.

Clinical Options Choice of co-current/countercurrent AcuSmart gives you the choice and flexibility to decide between the conventional countercurrent flow and a unique co-current flow option. This provides an improved priming efficiency by releasing air bubbles automatically in flow direction. Counter-Current (current market trend) Co-Current (new proposals) Additional Safeguardings Advanced Fluid Balance control AcuSmart has an advanced balance control system which ensures a balance error of 25g is not exceeded. This automatic monitoring and control system safeguards your patient from unexpected fluid balance inaccuracy that strongly influence the outcome of the CRRT treatment. Forgot to unclamp the Substitution bag after bag change Machine Stops the effluent pump until the patient fluid balance is adjusted to the normal level The Machine function with all pumps operating

Importance of Dose Managementin CRRT CRRT Dose is one of the critical factors which influence patient mortality. The results of a single center prospective randomized study showed a higher survival rate among the group receiving a treatment dose over 35ml/kg/hr, compared to the group receiving the conventional dose of 20ml/kg/hr (1). (1) Claudio Ronco, et. al., The Lancet Vol 356: 26-30, July 1, 2000 Prescribed Dose vs Delivered Dose The graph was generated from (2) However, a common problem with CRRT is the mismatch of prescribed and the delivered dose to the patient. Several clinical studies have shown that the delivered dose is generally lower in a range of 68-89% of the prescription (2). Moreover effective delivered dose is not monitored. (2) Vesconi S, et. al., Critical Care Vol 13 No 2, 15 Apr, 2009 Dose Mode DOSE Mode is specially designed to assess the balance between the prescribed dose and the delivered dose. In combination with the intuitive user interface, AcuSmart continuously updates the delivered dose information during the treatment. Continuous Dose measurement AcuSmart continuously updates the Dose status of the CRRT treatment. Downtime will also be calculated and AcuSmart will automatically adjust the treatment parameters to reach the target dose prescribed. Current DOSE shows the delivered dose in the current moment of the treatment. Average DOSE illustrates the overall dose which is measured from the beginning of the treatment.

Citrate Management Citrate Management CRRT is a complex field of therapy which requires frequent monitoring. During the treatment effective anticoagulation is necessary in order to avoid bleeding risks and to insure better circuit survival. While heparin is still widely used, according to recent reviews citrate should be the first choice anticoagulant for CRRT. (123) AcuSmart TM greatly simplifies the challenging management of regional citrate anticoagulation (RCA) and enables the use of safe RCA with its Citrate Management protocol. (1) Ouclemans-van Straaten, Citrical Care 2012,16:249, (2) Stucker, Ponte,Tataw, et. al., Critical Care 2012, 16:249, (3) KDIGO, 2B. Effective and Safe RCA increases CRRT effectiveness due to longer circuit survival and less clotting, therefore decreases therapy interruptions and ensures the successful delivery of the targeted CRRT dose. RCA increases treatment safety due to reduced bleeding risks. (4) (4) Hetzel, Schmitz, et. al., Nephrol Dial Transplant 2011,26:232-239 CONTROL Citrate Flow Rate CONTROL AcuSmart TM Citrate Management comes with the choice of two concentrated solutions: ACD-A 112.9mmol/L Trisodium 136mmol/L Reliable Citrate and Calcium management Citrate Dose CONTROL Calcium Dose No more need of complex calculations: 1. Selected fluid type in initial set-up of machine as standard setting. 2. Go to Prescription screen and input Haematocrit level and target blood flow rate. Confirm by pressing Save button. 3. On Anticoagulant screen insert the prescribed citrate flow (mmolabld) and patient Ca++ level (mmolabld). Also confirm by pressing Save. 4. If an adjustment of patient Ca - level is needed, insert additional calcium to increase or decrease Ca++ level of patient. Integrated pumps for a reliable control of RCA: If blood flow rate is changed, the citrate and effluent flow rates as well as infusion flow will be automatically adjusted. Therefore, AcuSmart TM ensures that the Ca++ replacement rates are in accordance with the doctor s prescription. Ca++ infusion flow can be changed any time during the treatment according to the patient s Ca++ level. 1 INITIAL SETUP SCREEN 2 PRESCRITPION SCREEN AcuSmart TM automatically calculates the citrate flow rate and Ca++ infusion flow rate. 3 ANTICOAGULANT SCREEN

Hemofilters For a proper CRRT management, MEDICA offers a range of hemofilters, available in different sizes and connections to cover all CRRT needs for neonates, children and adults. The range include 3 models based on the Medica proprietary membrane and 10 models based on. The high membrane permeability and excellent biocompatibility indicate the Medica Hemofilters for better CRRT performances. The range od Medica Hemofilters includes: D050, D100, D150 based on and DP03HE based on. These models are dedicated to neonates and children. DP07HE, DP09HE, DP12HE, DP15HE, DP60HE, DP120HE, DP150HE, DP190HE, DP230HE based on. These models are dedicated to adults. HEMOFILTERS PRODUCT CODE Product Code ETO Sterile Product Code Rays Sterile D050 (0,075 m 2 ) Paediatric M03698 M03745 D100 (0,15 m 2 ) Paediatric M03739 M03984 D150 (0,25 m 2 ) Paediatric M03069 M03137 DP03HE (0,3 m 2 ) Paediatric M03912 M03915 DP07HE (0,7 m 2 ) Adult M03913 M03916 DP09HE (0,9 m 2 ) Adult M03893 M03901 DP12HE (1,2 m 2 ) Adult M03895 M03903 DP15HE (1,5 m 2 ) Adult M03897 M03905 DP60HE (0,6 m 2 ) Adult M03892 M03900 DP120HE (1,2 m 2 ) Adult M03894 M03905 DP150HE (1,5 m 2 ) Adult M03896 M03904 DP190HE (1,9 m 2 ) Adult M03898 M03906 DP230HE (2,3 m 2 ) Adult M03899 M03907 is a registered trademark of Medica S.p.A is a registered trademark of Membrana GmbH Plasmafilters Medica now also offers a range of Plasmafilters available with 0.05, 0.1, 0.2, 0.4, 0.6, 0.7 and 1.0 m 2 membrane area. Solutions Available on request is a registered Trade Mark of MEDICA S.p.A. PLASMAFILTERS PRODUCT CODE Product Code ETO Sterile Product Code Beta Rays Sterile Plasmart 50 (0,05 m 2 ) Paediatric M03863 M03857 Plasmart 100 (0,10 m 2 ) Paediatric M03864 M03858 Plasmart 200 (0,20 m 2 ) Paediatric M03865 M03859 Plasmart 400 (0,40 m 2 ) Adult M03866 M03860 Plasmart 600 (0,60 m 2 ) Adult M03867 M03861 Plasmart 700 (0,70 m 2 ) Adult M90018 M90017 Plasmart 1000 (0,05 m 2 ) Adult M03868 M03862 TUBING SETS PRODUCT CODE Code AcuSmart line - C Adult M03873 R AcuSmart line - CP Paediatric M03881 R AcuSmart line - H Adult M03848 R AcuSmart line - HP Paediatric M03874 R Ster.

Snapshot of Machine Applications THERAPIES OVERVIEW Treatment Schematics E uent ow Heparin Diagram Citrate Diagram TREATMENT MODES NORMAL AND PEDIATRIC Heparin Citrate CVVHDF CVVHD CVVH SCUF PE

SPECIFICATIONS Treatment Modes (Heparinn + Citrate) Adult Paediatric Pump CVVH, CVVHD, CVVHDF, SCUF, TPE CVVH, CVVHD, CVVHDF, SCUF, TPE Blood Pump Flow Rate 1 to 400 ml/min Filtrate Pump Flow Rate 10 to 12.000 ml/h Dialysate Pump Flow Rate 10 to 12.000 ml/h Replacement Fluid Pump Syringe Pump Flow Rate Flow Rate Applicable Syringe 10 to 12.000 ml/h 0.1 to 150 ml/h Citrate Pump Flow Rate 1 to 1000 ml/h 20, 30 and 50 ml disposable syringe Other Components Blood Leek Detector Sensitivity > Blood Cell Concentration 0.15% Inlet Pressure Monitor Venous Pressure Monitor Range Range -500 to 500 mmhg -500 to 500 mmhg Filtrate Pressure Monitor Arterial Pressure Monitor Heater for Dialysate Heater for Replacement Fluid Range -500 to 500 mmhg Range -500 to 500 mmhg Range 30 to 40 C Range 30 to 40 C Display Size Other 10.4 inch Software Upgrade via USB storage or CF card Air Detector Sensitivity 0,01 ml at 10 ml/min Citrate Scale Weight MAX 2 kg Ultra Filtration Scale Weight MAX 15 kg Replacement/Dialysate Scale Weight MAX 15 kg Battery Operation Time 15 min for Blood Recovery Electrical ratings Rated Voltage 110 240 V Dimensions and Weight Height Width Depth Weight 150 cm 55 cm 75 cm 60 kg PRODUCT CODE: M03879 Specifications are subject to change without a notice.

M27375 REV 01 CDP 130418C MEDICA S.p.A. Via degli Artigiani, 7 41036, Medolla (Modena) - ITALY Phone +39 0535 51159 Fax + 39 0535 52605 info@medica.it www.medica.it UNI EN ISO 9001:2015 UNI CEI EN ISO 13485:2016