Integra. PyroCarbon Lunate SUTURE ANCHOR SURGICAL TECHNIQUE

Similar documents
Transforming Extremities

Integra. Silicone PIP Implant SURGICAL TECHNIQUE

Integra. PyroSphere System SURGICAL TECHNIQUE

Integra. Modular Radial Head System SURGICAL TECHNIQUE

Integra. Spider and Mini Spider Limited Wrist Fusion System SURGICAL TECHNIQUE

Integra. Thumb Joint Replacement PATIENT INFORMATION. with PyroCarbon implants

Integra. DigiFuse Cannulated Intramedullary Fusion System SURGICAL TECHNIQUE

Integra SURGICAL TECHNIQUE. MemoFix Super Elastic Nitinol Staple System. Super Elastic Nitinol Staple System

Integra. Modular Radial Head System SURGICAL TECHNIQUE

Ascension PIP Post-Operative therapy protocol

Modular Ulnar Head surgical technique. Transforming Extremities

WristMotion Wrist Hemiarthroplasty System Instructions for Use

JuggerKnot Soft Anchor 1.0 mm Mini. Scapholunate Ligament Repair/Reconstruction. Brochure and Surgical Technique

Surgical Technique Carpal Fusion

Surgical Technique. DISCLOSURE: This device is not approved for sale in the U.S.A. Customer Service:

The Wrist Fusion Set. Stainless Steel and Titanium TECHNIQUE GUIDE. Instruments and implants approved by the AO Foundation

Ascension. Silicone MCP surgical technique. surgical technique Ascension Silicone MCP

Ascension. MCP surgical technique. surgical technique Ascension MCP PyroCarbon Total Joint

Clover Staple. Surgical Technique

Forearm and Wrist Regions Neumann Chapter 7

ReMotion Total Wrist System

Integra. Titan Modular Shoulder System, 2.5

Acu-Loc Wrist Spanning Plate System. Surgical Technique

Integra. NuGrip CMC Implant SURGICAL TECHNIQUE

Introduction. The wrist contains eight small carpal bones, which as a group act as a flexible spacer between the forearm and hand.

Technique Guide Wrist Hemiarthroplasty System

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

Integra. TenoGlide Tendon Protector Sheet SURGICAL TECHNIQUE

Integra. First Choice DRUJ System Partial Ulnar / Modular Ulnar Head Implant SURGICAL TECHNIQUE

Integra. Silicone Toe System SURGICAL TECHNIQUE

Distal Radius Plate 2.4/2.7 dorsal and volar

Integra. Silicone MCP Joint Prosthesis SURGICAL TECHNIQUE

Chapter 19. Arthroscopic Bone Grafting for Scaphoid Nonunion. Introduction. Operative Technique. Radiocarpal and Midcarpal Exploration

Wrist Fusion Instrument and Implant Set.

Bipolar Radial Head System

Integra. Salto Talaris Total Ankle Prosthesis PATIENT INFORMATION

JuggerKnot Soft Anchor 1.0 mm Mini

Integra. Katalyst Bipolar Radial Head System SURGICAL TECHNIQUE

Index. Note: Page numbers of article titles are in boldface type. Hand Clin 21 (2005)

the shape, the size, the fit Ascension Modular Radial Head

Carpal rows injuries!

Surgical Technique Guide

Acutrak 2 Headless Compression Screw System Micro, Mini, and Standard Screws. Supplemental Use Guide Four Corner Fusion

JuggerKnot Soft Anchor 1.0 mm Mini

MICRONAIL. Intramedullary Distal Radius System SURGICAL TECHNIQUE

Integra. Freedom Wrist Arthroplasty System SURGICAL TECHNIQUE

Integra. Ascension MCP Joint Replacement SURGICAL TECHNIQUE

8/25/2014. Radiocarpal Joint. Midcarpal Joint. Osteology of the Wrist

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are

Wrist Arthritis & Partial Wrist Fusion

KATALYST. Bipolar Radial Head System. Surgical Technique. orthopedics. KATALYST English. PRODUCTS FOR SALE IN EUROPE, MIDDLE-EAST and AFRICA ONLY

Technique Guide Small Bone Fusion System

BIOKNOTLESSRC ROTATOR CUFF REPAIR SUTURE ANCHOR SURGICAL TECHNIQUE. Surgical Technique for Arthroscopic Rotator Cuff Repair. Raymond Thal, M.D.

Surgical Technique. SLIC Screw System

SWANSON BASAL THUMB IMPLANT SYSTEM. surgical technique presented by ALFRED B. SWANSON, MD, FACS, GRAND RAPIDS, MICHIGAN.

COMMON CARPAL INJURIES IN ATHLETES Nicholas A. Bontempo, MD Orthopedic Associates of Hartford I HAVE NO CONFLICTS OR DISCLOSURES TO REPORT OUTLINE

1 Design rational. 1.1 Implant

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

3. Ulno lunate, Ulno triquetral ligament. Poirier: Between RSC &LRL. 5. Dorsal intercarpal ligament

Integra Miltex. Because we are committed to limiting uncertainty, Integra continues to develop products in the area of dental care

Integra. SafeGuard Mini Carpal Tunnel Release System SURGICAL TECHNIQUE

Chapter 24. Arthroscopic Thumb Carpometacarpal Interposition Arthroplasty. Introduction. Operative Technique. Patient Preparation and Positioning

Acu-Loc Wrist Plating System. Surgical Technique

Integra. Endoscopic Gastrocnemius Release System SURGICAL TECHNIQUE

Technique Guide KISSloc Suture System

Integra Miltex. Because we are committed to limiting uncertainty, Integra continues to develop products in the area of dental care

This presentation is the intellectual property of the author. Contact them for permission to reprint and/or distribute.

Integra Use of TenoGlide Tendon Protector Sheet to Protect an Extensor Tendon Repair of the Thumb CASE STUDY

E-CENTRIX. Ulnar Head Replacement SURGICAL TECHNIQUE

Hand and wrist emergencies

Application Guide for Full-Thickness Wounds

Correction System. Surgical Technique

SWANSON titanium CARPAL LUNATE & CARPAL SCAPHOID IMPLANTS. surgical technique

TABLE OF CONTENTS. Limited intercarpal joint arthrodesis (including isolated capitolunate, two-column and four-corner fusions)

Maestro. Wrist Radial Fracture System. Surgical Technique. Knees Hips Extremities Cement and Accessories PMI Trauma Technology

Ligaments of Elbow hinge: sagittal plane so need lateral and medial ligaments

Silicone PIP, MCP & MCP-X (PreFlex)

For the Attention of the Operating Surgeon: IMPORTANT INFORMATION ON THE MATRIXRIB FIXATION SYSTEM

CableFIX Xpress Carpometacarpal Fixation System. Operative technique

rhead System Extended stems Operative technique

rhead System Radial Head Arthroplasty Operative technique

PIPR Proximal Interphalangeal Replacement. Operative Technique

Integra. Proximal Humeral Fracture Plate CASE STUDY

EndoRelease ENDOSCOPIC CUBITAL TUNNEL RELEASE SYSTEM

Wrist Fusion System SURGICAL TECHNIQUE

2.4 mm Variable Angle LCP Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

Arhtroscopy of the wrist joint: Setup, instrumentation, anatomy & indications

QUICK REFERENCE GUIDE. The Pennig Dynamic Wrist Fixator. Part A: Trans-articular application

Chapter 4: Forearm 4.3 Forearm shaft fractures, transverse (12-D/4)

MCQWeek2. All arise from the common flexor origin. The posterior aspect of the medial epicondyle is the common flexor origin.

Mini External Fixator

Wrist & Hand Assessment and General View

EXAMINATION OF THE WRIST BEYOND THE BASICS OMA SPORT MED Janice Harvey MD CCFP CFFP Dip. Sp Med.

Integra. ADVANSYS Plating System SURGICAL TECHNIQUE

VariAx TM Distal Radius Locking Plate System

Trapezium is by the thumb, Trapezoid is inside

Visualize, stabilize, mobilize. Wristore * Distal Radius Fracture Fixator Abbreviated Surgical Technique

Transcription:

Integra PyroCarbon Lunate SUTURE ANCHOR SURGICAL TECHNIQUE

Table of Contents Introduction Indications... 1 Contraindications... 1 Warnings... 2 Precautions... 2 Product Description...2 Surgical Technique Step 1: Skin Incision... 3 Step 2: Capsulotomy...4 Step 3: Resection of the Lunate... 5 Step 4: Sizing... 5 Step 5: Suture Anchor Placement...6 Step 6: Implant Placement & Capsular Repair...6 Step 7: Closure...6 Postoperative Care...6 Instrumentation...Back Cover Ordering Information...Back Cover Indications The PyroCarbon Lunate is intended for replacement of the lunate bone in the proximal carpal row of the wrist in the presence of: Avascular necrosis (Kienboch s disease) Localized osteoarthritic changes Long-standing dislocations Contraindications Acute or chronic infection Radial scaphoid arthritis Gross carpal instability See package insert for full prescribing information.*

Warnings Strenuous loading, excessive mobility, and articular instability all may lead to eventual failure by loosening, fracture, or dislocation of the device. Patients should be made aware of the increased potential for device failure if excessive demands are made upon it. Do not modify the PyroCarbon Lunate implant in any manner. Reshaping the implant using cutters, grinders, burrs, or other means will damage the structural integrity of the device. Precautions Do not use the PyroCarbon Lunate in a joint where soft tissue reconstruction cannot provide adequate stabilization. Similar to the native lunate, the PyroCarbon Lunate attains stabilization from the surrounding capsuloligamentous structures. If soft tissue reconstruction cannot provide adequate stabilization, the device may dislocate or loss of motion may occur. Do not resterilize this device. Resterilization could lead to mishandling and surface damage that could result in implant fracture and/or particulate debris. Do not reuse this device. Reuse of this product may result in infection or other systemic complication that may affect the patient s overall health. Additionally, the reuse of this product could adversely affect function of the device. Any implant that has been damaged, mishandled, or removed from the sterile field may have surface damage that could result in implant fracture and/or particulate and should be discarded. Do not grasp the PyroCarbon Lunate implant with metal instruments, or instruments with teeth, serrations, or sharp edges. The PyroCarbon Lunate is made of pyrocarbon, which is a ceramic-like material. Mishandling implants could cause surface damage that reduces their strength which could result in implant fracture and/or particulate debris. Do not use metal suture/wire for implant fixation as damage to the implant may occur that reduces strength which could result in implant fracture and/or debris generation. The PyroCarbon Lunate has not been evaluated for safety and compatibility in the MR environment. The PyroCarbon Lunate has not been tested for heating or migration in the MR environment. Product Description The PyroCarbon Lunate is an anatomically designed lunate replacement with essentially the same shape as the native lunate bone. The Lunate implant acts as an articulating spacer to maintain the relationship of adjacent carpal bones after excision and to maintain mobility of the wrist. The articular concavity that captures the capitate is more exaggerated to enhance stability. The Pyrocarbon Lunate is constructed of a high strength On-X PyroCarbon layer deposited on a graphite substrate. The graphite is impregnated with tungsten making the Lunate implant radiopaque. The Pyrocarbon Lunate is available in 5 sizes for use in left or right applications. *ESSENTIAL PRODUCT USE INFORMATION: For additional important information pertaining to the use of this product, please see product package insert. This information was current at the time of printing, but may have been revised after that date. 2

Surgical Technique As the manufacturer of this device, Integra LifeSciences Corporation does not practice medicine and does not recommend this or any other surgical technique for use on a specific patient. The surgeon who performs any procedure is responsible for determining and using the appropriate technique in each patient. Caution: Federal law restricts this device to sale by or on the order of a physician or practitioner. Step 1 Skin Incision 1-1 Make a 7-10 cm midline dorsal longitudinal incision across the radiocarpal area. 1-1 It is recommended to support the wrist on a modest bump to induce a small degree of flexion. 1-2 The third extensor compartment is incised and then elevated to create and ulnarly based flap of the fourth compartment roof and a radially based flap of the second compartment roof. Care is taken to identify and protect the dorsal radial and ulnar sensory nerves. The extensor pollicis longus is retracted radially while the extensor digitorum communis tendons are retracted ulnarward. 1-2 3

Step 2 Capsulotomy 2-1 Specific landmarks are identified and palpated on the wrist. These mark the placement of the capsular incision. Caution 2-1 is taken to protect the terminal branch of the posterior interosseous nerve. Landmarks: 1. The midpoint of the dorsal radiocarpal ligament attachment to the radius. 2. The dorsal tubercle of the triquetrum. 3. The sulcus between the scaphoid and the trapezoid. These landmarks are marked, and the surgeon connects the dots with a full thickness incision. This capsular incision reveals the longitudinally split fibers of the DIC and DRC ligaments. Once the ligament-splitting incisions are made, the capsulotomy can be completed by following the dorsal rim of the radius to the level of the styloid process. When the radio-carpal capsulotomy is complete, the radially based flap of capsule is tangentially elevated off the dorsal surfaces of the capitate and lunate. After the capsulotomy has been created, the surgeon should closely examine the scaphoid fossa within the radius. If there is evidence of significant arthritis, the procedure should be abandoned for an alternative wrist salvage procedure, as ongoing pain will continue at the radioscaphoid fossa despite replacement of the lunate. Alternative Capsulotomy: 2-2 The wrist is palpated and marked prior to elevation of the dorsal capsular flap, which will then provide access to the radiocarpal and midcarpal joints. The distal margin of Lister s tubercle is identified, and a J shape line is drawn toward the dorsal tubercle of the triquetrum. An incision is then made to follow this line, extending from the distal margin of Lister s tubercle obliquely toward the dorsal tubercle of the triquetrum. 2-2 Alternative Capsulotomy This incision is designed to split the fibers of the radiocarpal ligament and preserve the branches of the posterior interosseous nerve within the flap. The capsular flap is then raised tangentially off the dorsal surface of the scaphoid, lunate, triquetrum, and the proximal portion of the capitate. If additional exposure is required, an additional cut may be made in line with the fibers of the dorsal intercarpal ligament extending from the triquetrum towards the trapezium. This will further expose the neck of the capitate and the waist of the scaphoid bone, if necessary for completion of the surgical procedure. 4

Step 3 Resection of the Lunate 3-1 The lunate is resected with great care to remove the lunate in-total if possible, to allow for easy assessment of implant size. If the lunate has experienced significant collapse or fragmentation, templating against the normal wrist is recommended. 3-1 Step 4 Sizing 4-1 The PyroCarbon Lunate comes in 5 sizes for the right and left hand. The deep concavity of the lunate straddles the head 4-1 of the capitate distally. The shorter flat surface articulates with Larger Triquetral the scaphoid and the longer surface with the triquetrum. Surface Sizing Templates: Triquetrum The Sizing Template provided can be used to help estimate the implant fit on the surfaces of the triquetrum, scaphoid, and capitate. Radiopaque Lunate Trials are also used to help with determining the correct size implant. Implant sizing should always start with the smallest trial incrementing up in size until a comfortable fit in the lunatectomy space is obtained. Reference Gilula s lines and take care to avoid overstuffing the joint, as this can potentially distract the first carpal row and could result in excessive implant force loading and displacement. Smaller Scaphoid Surface Scaphoid 5

Step 5 Suture Anchor Placement 5-1 It is recommended to position the suture anchors in the outer most corner of the sizing template to increase stabilization of the implant (see inset). 5-1 Sizing Templates: Triquetrum Utilizing the Sizing Template and a felt tip pen, mark drill points on the scaphoid which will allow insertion of two Mitek mini anchors with several strands of Number 2 Orthocord or similar permanent suture. (DePuy-Mitek, Johnson & Johnson). Two pilot holes are then drilled into the scaphoid, but the anchors are not placed until the triquetrum has been prepared. Scaphoid Attention is turned to the triquetrum surface. Using the Sizing Template, two marks are made using a felt tip pen. It is recommended the marks be placed on the outer most corner of the template to improve implant stability. A 2 mm drill is then utilized to prepare holes through the triquetrum to allow passage of two channels through the body of the triquetrum. Step 6 Implant Placement and Capsular Repair 6-1 Utilizing a 18 gauge spinal needle and tendon passer (Chia Passer, DePuy), or simple wire loop, may help facilitate the passage of the suture through the triquetrum. 6-1 Scaphoid Surface Triquetral Surface Before inserting the implant, the wound is thoroughly irrigated with saline solution to remove all debris. The PyroCarbon implant should not be handled with metal instruments. Two Mitek anchors are placed in the scaphoid; the suture material is passed through the PyroCarbon Lunate prosthesis and then passed through the previously created channels in the triquetrum. Note that the short flat surface articulates with the scaphoid and the long surface articulates with the triquetrum. The sutures that are passing through the implant and triquetrum are brought ulnarly and held snugly around the triquetrum. Confirmation X-rays are taken to ensure position of the lunate implant is satisfactory. Following satisfactory confirmation, the two arms of the suture are tied snugly to each other to produce a stabilization of the lunate prosthesis. Step 7 Closure The capsular flap is repaired with 2-0 Vicryl suture, and the extensor retinaculum is repaired with 3-0 Vicryl suture. Skin incisions are closed with 4-0 nylon suture. Wrist may be placed through range of motion, and Lunate position verified by X-ray. Postoperative Care The extremity is elevated for 1-2 days, and patient is instructed to move the shoulder and fingers. A sugar tong splint is applied for the first 3-5 days. This is then changed to a short arm cast. Wrist immobilization is maintained for 6-8 weeks. Skin suture can be removed at 2 weeks. Postoperative therapy should include isometric gripping and movements of the shoulder. Full usage of the wrist is resumed at 12 weeks, unless an intercarpal fusion was performed, which requires a longer casting period. 6

Integra PyroCarbon Lunate Instrumentation 1. Sizing Templates 2. Radiopaque Trials 1 2 Implants Catalog Number Description LUN-710-01 Lunate Implant, Size 01 LUN-710-02 Lunate Implant, Size 02 LUN-710-03 Lunate Implant, Size 03 LUN-710-04 Lunate Implant, Size 04 LUN-710-05 Lunate Implant, Size 05 Instruments Catalog Number Description TRL-715-01T Lunate Trial, Size 01 TRL-715-02T Lunate Trial, Size 02 TRL-715-03T Lunate Trial, Size 03 TRL-715-04T Lunate Trial, Size 04 TRL-715-05T Lunate Trial, Size 05 SZT-715-01S Lunate Sizing Template, Size 01 SZT-715-02S Lunate Sizing Template, Size 02 SZT-715-03S Lunate Sizing Template, Size 03 SZT-715-04S Lunate Sizing Template, Size 04 SZT-715-05S Lunate Sizing Template, Size 05 Availability of these products might vary from a given country or region to another, as a result of specific local regulatory approval or clearance requirements for sale in such country or region. n Non contractual document. The manufacturer reserves the right, without prior notice, to modify the products in order to improve their quality. n Warning: Applicable laws restrict these products to sale by or on the order of a physician. n Consult product labels and inserts for any indication, contraindications, hazards, warnings, precautions, and instructions for use. For more information or to place an order, please contact: United States, Canada, Asia, Pacific, Latin America USA 800-654-2873 888-980-7742 fax n International +1 609-936-5400 +1 609-750-4259 fax n integralife.com/contact Manufacturer: Ascension Orthopedics 11101 Metric Blvd Austin, TX 78758 n USA Integra and the Integra logo are registered trademarks of Integra LifeSciences Corporation or its subsidiaries in the United States and/or other countries. 2017 Integra LifeSciences Corporation. All rights reserved. Printed in USA. 3K LC-04-717-001 Rev. D 0052122-2-EN