Emile N. Brown, MD, and Scott D. Lifchez, MD

Similar documents
Ultrasonographic Assessment of the Flexor Pollicis Longus Tendon After Plate Fixation

Acute Rupture of Flexor Tendons as a Complication of Distal Radius Fracture

Failed Extensor Indicis Proprius Tendon Transfer for Extensor Pollicis Longus Tendon Rupture after Distal Radial Fracture

Acute Rupture of Flexor Digitorum Profundus Tendon Associated with Distal Radius Fracture: A Case Report

Complications of Distal Radius Fractures. How to Treat a Distal Radius Fx 11/13/2017. Michael S. Bednar, M.D. Loyola University Chicago

Disclosure. 85% Dorsal. 15% Volar. Distal Radius Fractures- Volar Plating for All. Skeletal Dynamics- Consultant

CASE REPORT. Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report

Mark VanDer Kaag 1, Ajmal Ikram 2. Hand Unit, Tygerberg Hospital University of Stellenbosch

Hardware-Related Complications After Dorsal Plating for Displaced Distal Radius Fractures

Fractures and dislocations of the fingers

MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS FOR DISTAL RADIUS FRACTURES: SURGICAL TECHNIQUE M. TOBE 1, K. MIZUTANI 1, Y. TSUBUKU 1, Y.

Disclosures. Distal Radius Fractures 5/16/2017. Distal Radius Fractures: Complications & Limitations of the Volar Approach

Clinical Study Rate of Improvement following Volar Plate Open Reduction and Internal Fixation of Distal Radius Fractures

Hand injuries. The metacarpal bones may fracture through the base, shaft or the neck.

Distal radius fractures

Treatment of unstable distal radius fractures with the volar locking plate

Tendon pathology in patients with distal radius palmar locked plate: incidence and clinical outcome of treatment

6/5/2018. DISCLOSURES Hassan R. Mir, MD, MBA, FACS. Evolution of Distal Radius Fracture Treatment [Chung Hand Clinics 2012]

Clinical Study Dorsally Comminuted Fractures of the Distal End of the Radius: Osteosynthesis with Volar Fixed Angle Locking Plates

Radiographic Evaluation of Dorsal Screw Penetration After Volar Fixed-Angle Plating of the Distal Radius: A Cadaveric Study

The Utility of the Fluoroscopic Skyline View During Volar Locking Plate Fixation of Distal Radius Fractures

Distal radius fractures raises considerable interest and

Wrist and Hand Complaints

The Birmingham Hook Plate Treatment Of Irreduceable Displaced Mallet Avulsion Fractures: A Technical Note

A STUDY OF THE FUNCTIONAL OUTCOME OF LOW PROFILE DORSAL PLATING IN DISTAL END RADIUS FRACTURES

Long-term Results of Dorsally Displaced Distal Radius Fractures Treated With the Pi-Plate: Is Hardware Removal Necessary?

University of Groningen. Fracture of the distal radius Oskam, Jacob

Acu-Loc Wrist Plating System. Surgical Technique

WINSTA-R. Distal Radius System

Ligaments of Elbow hinge: sagittal plane so need lateral and medial ligaments

Difference Between Angle You Can Bend Your Left Wrist Back vs Your Right Wrist Jenna Priest Science Department Altoona High School January 25, 2017

Korean Type Distal Radius Anatomical Volar Plate System: A Preliminary Report

Fracture and Dislocation of Metacarpal Bones, Metacarpophalangeal Joints, Phalanges, and Interphalangeal Joints ( 1-Jan-1985 )

Clinical examination of the wrist, thumb and hand

Reproducibility of Three Dimensional Digital Preoperative Planning for the Osteosynthesis of Distal Radius Fractures

Intra articular distal radius fractures and volar plate fixation: a prospective study

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

journal ORIGINAL RESEARCH

DVR Crosslock Distal Radius Plating System. Product Brochure

Injury, Int. J. Care Injured 42 (2011) Contents lists available at ScienceDirect. Injury. journal homepage:

Acu-Loc Wrist Spanning Plate System. Surgical Technique

Bridging external fixation and supplementary Kirschner-wire fixation versus volar locked plating for unstable fractures of the distal radius

Acu-Loc 2 Wrist Plating System

Closed Proximal Phalangeal Fracture Management in Hand: An Outcome Analysis

Disclosures. Epidemiology 10/12/2015. Distal Radius Fractures: Staying Out of Trouble

Surgical Technique. Wrist Plating System

INTERNAL FIXATION OF THE METACARPALS AND PHALANGES P. BURGE

SPECIAL ARTICLE. Missed tendon injuries INTRODUCTION

Locking Radial Head Plates

Case Presentation: Comminuted Fractures of the Proximal Ulna 11/28/2017. Disclosures. Surgical Strategy. Implant Choice. Melvin P.

Biceps Brachii. Muscles of the Arm and Hand 4/4/2017 MR. S. KELLY

8 Recovering From HAND FRACTURE SURGERY

BASIC PRINCIPLES OF HAND TRAUMA: ARE CHILDREN DIFFERENT? SUSAN THOMPSON, MD, FRCSC

5/9/2017. Distal Radius Fractures: What s New? What s New? Or Maybe New to you. Single Pak Sterile distal radius kits

Volar fixed-angle plating for distal radius fractures 刀圭会協立病院 津村敬

AJO needle, and compartment pressures were measured

Volar Plate Avulsion Fractures

THE EPIDEMIOLOGY OF HAND EMERGENCIES

Management of Hand Palsies in Isolated C7 to T1 or C8, T1 Root Avulsions

Index. Note: Page numbers of article titles are in boldface type. Hand Clin 21 (2005)

Acu-Loc 2 Wrist Plating System. Surgical Technique

JMSCR Vol 05 Issue 06 Page June 2017

Visualize, stabilize, mobilize. Wristore * Distal Radius Fracture Fixator Abbreviated Surgical Technique

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

Forearm Fracture Solutions. Product Overview

Fractures of distal end of Radius: A study on fracture reduction and stable fixation

Use of Low-profile Palmar Internal Fixation in Digital Replantation

From the Department of Orthopedics, Tongji Hospital, Tongji University, Shanghai, China

Fractures and dislocations around elbow in adult

ORIGINAL ARTICLE TREATMENT DISTAL RADIUS FRACTURE WITH VOLAR BUTTRESS TECHNIQUE- A CLINICAL STUDY

SURGERY OF THE HAND INTRODUCTION CASE REPORT. Hee-June Kim 1, Hyun-Joo Lee 1, Dong-Hyun Kim 1, Joon-Woo Kim 1, Ji Won Oh 2

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Distal Radius Plate 2.4/2.7 dorsal and volar

Volar Distal Radius Plating System Surgical Technique

Int J Clin Exp Med 2017;10(1): /ISSN: /IJCEM

Urgent Cases and Foreign Bodies

Functional Outcome Of Intraarticular Distal Radius Fractures Managed By Volar Locking Compression Plate A Prospective Study

Kousuke Iba 1*, Yasuhiro Ozasa 1, Takuro Wada 1, Tomoaki Kamiya 1, Toshihiko Yamashita 1, Mitsuhiro Aoki 2. Abstract

Complications and functional outcome following fixation of complex, intra-articular fractures of the distal radius with the AO Pi-Plate

Case Report Bone Resection for Isolated Ulnar Head Fracture

Intrinsic muscles palsies of the hand Management of Thumb Opposition with BURKHALTER s Procedure

Revisiting the Curtis Procedure for Boutonniere Deformity Correction

COMPARATIVE STUDY OF FUNCTIONAL OUTCOME OF EXTERNAL AND INTERNAL FIXATION IN TREATMENT OF COMMINUTED DISTAL RADIUS FRACTURES

Volar Distal Radius Plating System Surgical Technique

Main Menu. Wrist and Hand Joints click here. The Power is in Your Hands

Hand and wrist emergencies

DVR Anatomic Plate. Surgical Technique

Surgical Management of Distal end Radius Fractures by Various Methods: A Prospective Study

Levels of the anatomical cuts of the upper extremity RADIUS AND ULNA right

Common. Common Hand Problems in Elite Athletes

Introduction to Ultrasound Examination of the Hand and upper

Physical therapy of the wrist and hand

epak Single-Use Delivery System

Nerves of Upper limb. Dr. Brijendra Singh Professor & Head Department of Anatomy AIIMS Rishikesh

A novel method of treating isolated unicondylar fracture of the head of the proximal phalanx: A case report

Distal Radius and Distal Ulna Plates System Self-Tapping Spherical Locking Screw Self-Tapping Conical Locking Screw Cortex Screw

Malunited extra-articular distal radius fractures: corrective osteotomies using volar locking plate

Bipolar Radial Head System

Transcription:

Flexor Pollicis Longus Tendon Rupture After Volar Plating of a Distal Radius Fracture: Pronator Quadratus Plate Coverage May Not Adequately Protect Tendons Emile N. Brown, MD, and Scott D. Lifchez, MD Department of Plastic Surgery, Johns Hopkins Bayview Medical Center, Baltimore, MD Correspondence: Slifche1@jhmi.edu Published November 9, 2011 Objective: The senior author previously reported a case of rupture of the flexor policis longus tendon after volar plating of a distal radius fracture. We hypothesized that restoration of the pronator quadratus to its native position after plating might prevent this problem. Methods: The authors report a new case of irritation of the flexor policis longus 2.5 years after volar plating of a distal radius fracture. The plate was in good contact with the bone, and the pronator quadratus had been restored to its native position. Despite this, there was a partial-thickness laceration of the tendon over the plate and a defect in the pronator quadratus muscle which had been between the plate and the tendon. Results: The patient was treated with removal of the plate and repair of the tendon. She never lost function of the flexor policis longus tendon and has full function of her hand. Conclusions: The authors believe that restoration of the pronator quadratus to its native position after volar plating of a distal radius fracture does protect the overlying flexor tendons. Even with this step, tendon irritation can still occur. The authors advise their patients at the time of discharge from initial treatment of their distal radius fracture to be vigilant for any evidence of flexor tendon irritation and to return for evaluation if they have any suspicion of this. Over the past decade, volar plating of distal radius fractures has become increasingly popular. Compared to dorsal plate fixation where the extensor tendons are in direct contact with the plate, the volar approach has a theoretical advantage in reducing complications of tendon irritation given the greater distance between the flexor tendons and the volar surface of the radius. 1 However, there remains a risk of flexor tendon irritation with volar plate fixation, despite recent advances in plate design. 2 The senior author previously reported a case of flexor policis longus (FPL) rupture in a 65-year-old woman associated with volar plating of a distal radius fracture, necessitating removal of the plate and tendon repair. 3 In that patient, a second-generation, low-profile, The authors have no financial or other conflicts to disclose. 461

eplasty VOLUME 11 fixed-angle, volar locking plate had been placed by an outside surgeon. During exploration, the plate was found to be fully in contact in bone with no prominent edges or screw heads. Orbay 1 has advocated restoration of the pronator quadratus to its native position after volar plating of the radius, providing a layer of vascularized tissue between the plate and the flexor tendons. In our previously reported patient, this had not been done. We hypothesized that tendon irritation might have been avoided by reapproximation of the pronator quadratus over the plate. CLINICAL CASE Figure 1. The patient retained ability to flex the left thumb interphalangeal at the time of presentation but complained of a grinding sensation at the wrist when she did. We now present the case of a 75-year-old right hand dominant woman who fell down the stairs in her home and impacted her left hand in extension against a wall. She was found to have a left intra-articular distal radius fracture with greater than 25 degrees of dorsal tilt. She initially underwent closed reduction and splinting; however, subsequent imaging 1 week later revealed loss of reduction. Therefore, we took her to the operating room 2 weeks after the initial injury and performed open reduction and internal fixation with a secondgeneration, low-profile, fixed-angle, volar locking plate (Acumed, Hillsboro, Oregon). The 462

BROWN AND LIFCHEZ pronator quadratus muscle was restored to its native position and provided coverage of the entire plate. The patient did well postoperatively and achieved union and full recovery of wrist and hand function. Figure 2. The distal radius plate is in good contact with the bone. Two and half a years later, the patient returned with a 2-month history of volar radialsided wrist pain. She also complained of a rubbing sensation in this area with thumb motion. On examination, there was palpable crepitus with thumb interphalangeal joint flexion suggesting irritation of the flexor policis longus tendon. The patient was able to actively fire her FPL (Fig 1). The patient was taken for surgical exploration, which revealed mature union of the fracture. The plate was found to be in good contact with bone with no prominent edges (Fig 2). However, an obvious defect in the previously intact pronator quadratus was noted, where it appeared as if the plate had eroded through the muscle. The repair of the connective tissue at the edges of the muscle to the surrounding periosteum/brachioradialis radially and joint capsule distally appeared intact. There was clear demarcation between the intact more proximal muscle fibers and the more distal ruptured area of the muscle (Fig 3). Irritation of the flexor pollicis longus tendon was identified in this location. There was a partial thickness laceration comprising approximately 20% of the tendon substance (Fig 4). This was repaired using 5-0 polypropylene epitendinous sutures. The plate was 463

eplasty VOLUME 11 removed and the remaining intact pronator quadratus was again laid back in its native position. Figure 3. A defect in the pronator quadratus was found in surgery underlying where the FPL tendon passed. More distally and radially, the repair of the pronator to its native bed performed at the end of the first procedure remained intact. At final follow-up examination postoperatively, the patient reported complete resolution of her previous volar radial-sided wrist pain. On examination, she had good motion of her thumb interphalangeal joint with no palpable crepitus. DISCUSSION Complication rates as high as 22% and 27% have been reported after volar plating of distal radius fractures. 4,5 A recent study of 594 patients reported 13 cases of flexor tendon irritation, with one case of complete tendon rupture occurring 8 months after surgery. 6 This irritation involved the flexor policis longus and/or flexor digitorum profundus tendons and was observed as late as 41 months after surgery. The authors also identified plate type and surgeon volume as potential risk factors for late complications after volar plate fixation. 464

BROWN AND LIFCHEZ However, this study made no mention of whether or not the pronator quadratus was laid back over the plate during implantation. Figure 4. A 20% erosion of the FPL was noted. This was repaired with epitendinous 6-0 polypropylene suture. In our practice, the pronator is elevated at the start of the operation to include sufficient connective tissue distally and radially to allow for it to be restored to its native position at the end of the procedure. A small rim of brachioradialis is raised with the muscle radially and a small rim of periosteum is raised with the muscle distally. Maintaining this connective tissue during elevation allows sufficient purchase of sutures to bring the pronator muscle back down to its native position in a manner that provides complete coverage of the underlying hardware at the end of the procedure. Suturing the muscle with the wrist in neutral or even slight pronation also aids with allowing the muscle to be brought back into the appropriate position in a tension-free manner. In the current patient, we observed flexor pollicis longus irritation despite coverage of the plate with the pronator quadratus at the initial surgery. As with our previously reported patient, she received a second generation, low-profile volar locking plate that was fully in contact with the bone. The current patient had her initial surgery by the senior author, and the pronator was returned to its native position including full coverage of the plate at the end of the procedure. Douthit 7 observed that the overall bulk of the pronator quadratus is 465

eplasty VOLUME 11 variable, and the muscle can be relatively thin in middle-aged women. This may have been a contributing factor in our case. More research in this area is needed and may lead to further refinements in plate design and surgical technique. Although we have been unable to definitively prevent flexor tendon irritation after volar plating of distal radius fractures, we do not currently advocate routine removal of this hardware. Despite the 2 cases we have seen, this remains a relatively rare complication. 6 The risks and operative costs of routinely removing this hardware would outweigh the potential benefits. However, on the basis of our experience with these complications, we stress to all patients at their final postoperative visit that they must inform us of any new increase in pain or crepitus, or change in active range of motion. It is also essential for the surgeon to react quickly to these complaints and potentially intervene before complete tendon rupture occurs. REFERENCES 1. Orbay L. The treatment of unstable distal radius fractures with volar fixation. Hand Surg. 2000;5:103-12. 2. Berglund LM. Complications of volar plate fixation for managing distal radius fractures. JAmAcadOrthop Surg. 2009;17:369-77. 3. Lifchez SL. Flexor pollicis longus tendon rupture after volar plating of a distal radius fracture. Plast Reconstr Surg. 2010;125:21e-23e. 4. Rozental TD, Blazar PE. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg 2006;31A:359-65. 5. Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma. 2007;21:316-22. 6. Soong M. Fractures of the distal radius: risk factors for complications after locked volar plate fixation. J Hand Surg Am. 2011;36:3-9. 7. Douthit JD. Volar plating of dorsally comminuted fractures of the distal radius: a 6-year study. Am J Orthop (Belle Mead NJ) 2005;34:140-7. 466