Original Research. Figure 1: Conventional Stethoscope.

Similar documents
TEMPORO-MANDIBULAR JOINT DISORDERS

A jaw exerciser for fibrous ankylosis of the temporomandibular joint

SUBJECT: Physics TEACHER: Mr. S. Campbell DATE: 15/1/2017 GRADE: DURATION: 1 wk GENERAL TOPIC: The Physics Of Hearing

accurate perception. Stethoscopes

Where is the Temporo-Mandibular Joint?

ISLAMABAD ACADEMY PHYSICS FOR 10TH CLASS (UNIT # 13)

Prevalence of Temporomandibular Joint Dysfunction and Its Signs among the Partially Edentulous Patients in a Village of North Gujarat

Prosthetic Management of TMJ Disorders

Sound and its characteristics. The decibel scale. Structure and function of the ear. Békésy s theory. Molecular basis of hair cell function.

Initial Doctor Questionnaire

Articulators. 5- Wax up and refining the occlusion for dental restorations.

Frequency refers to how often something happens. Period refers to the time it takes something to happen.

U.S. DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health

Examination of the Temporomandibular Joint- A Review

Comparison of Rate of Canine Retraction into Recent Extraction Site with and without Gingival Fiberotomy: A Clinical Study

17.4 Sound and Hearing

Jaw relations and jaw relation records

A CLASSIFICATION SYSTEM FOR THE MANAGEMENT OF BIOMECHANICAL FACTORS IN DENTISTRY

Sensitivity. is the basis of accurate perception. Stethoscopes

3000 Series Articulator System

Transfer of Sound Energy through Vibrations

Three-dimensional finite element analysis of the human middle ear and an application for clinics for tympanoplasty

Temporomandibular Joint Disorders

Issues faced by people with a Sensorineural Hearing Loss

Screening orthodontic patients for temporomandibular disorders

Osseointegrated dental implant treatment generally

ABSTRACT. are of greater importance than others, the most important of

Technical Discussion HUSHCORE Acoustical Products & Systems

WHAT ARE ANTI-SNORING APPLIANCES?

Horizontal jaw relations: The relationship of mandible to maxilla in a

Vertical relation: It is the amount of separation between the maxilla and

Intra-rater reliability of TMJ joint vibration a pilot study

Horizontal Jaw Relation

Chapter 3. Sounds, Signals, and Studio Acoustics

Immediate Loading with Flapless Implant Surgery for Rehabilitation of Single Bound Edentulous Space

The dynamic range of TMJ sounds

IsoAcoustics Technology Explained!

TURN CLASS II INTO SIMPLE CLASS I PATIENTS.

With judicious treatment planning, the clinical

OCCLUSION: PHYSIOLOGIC vs. NON-PHYSIOLOGIC

Sound Workshop. What is sound Longitudinal Waves Frequency and pitch Hearing ranges Sounds in solids, liquids and gases Sound in a vacuum

Evaluation of TMJ sound on the subject with TMJ disorder by Joint Vibration Analysis

The development of modern Oral

Methods of determining vertical dimension of occlusion

STRAIGHT TALK about CROOKED TEETH: Key #4, Healthy TMJ Function

Thebemed Dental Benefit Tables 2019

MDJ Stabilization Splint (Night Guard, Mouth Guard) Vol.:6 No.:2 2009

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

A SIMPLE METHOD FOR CORRECTION OF BUCCAL CROSSBITE OF MAXILLARY SECOND MOLAR

Connect your Scanner to SomnoMed Canada. SOMGauge Protrusive Bite Recording - Manual. Scanning Impressions - Lower and Upper

Maxillofacial Patient Information Leaflet

Measurement of air-conducted and. bone-conducted dental drilling sounds

MYOFASCIAL PAIN DYSFUNCTION SYNDROME - A CLINICAL STUDY

Alliance-Midmed Dental Benefit Table 2019

TMD: Epidemiology: Signs and Symptoms

Applied to never missing a beat. 3M Littmann Stethoscopes. 3M Red Dot Electrodes. Tunable technology

Conventional Radiographic Assessment of Temporomandibular Joint Disorders in Young Saudi Patients: A Retrospective and Prospective Radiographic Study

TEMPOROMANDIBULAR JOINT DISORDER: ROLE OF BILATERAL BALANCED AND CANINE GUIDANCE OCCLUSAL SPLINTS: A CLINICAL STUDY

Bone conduction hearing solutions from Sophono

Principle of Occlusion

Prosthetic Options in Implant Dentistry. Hakimeh Siadat, DDS, MSc Associate Professor

UNDERSTANDING HEARING LOSS

UNDERSTANDING HEARING LOSS

PC BASED AUDIOMETER GENERATING AUDIOGRAM TO ASSESS ACOUSTIC THRESHOLD

Developing Facial Symmetry Using an Intraoral Device: A Case Report

AND9020/D. Adaptive Feedback Cancellation 3 from ON Semiconductor APPLICATION NOTE INTRODUCTION

The effect of occlusal splint treatment on the temporomandibular joint dysfunction patient

Introduction to Occlusion and Mechanics of Mandibular Movement

Mandibular ridge changes after adaptation. An issue of shortened dental arch to be considered from changes of soft tissues after unattended tooth loss

Enablemed Dental Benefit Table 2019

A Study to evaluate Some of the Esthetic Factors determining Attractive Smile

Welcome to the LISTEN G.R.A.S. Headphone and Headset Measurement Seminar The challenge of testing today s headphones USA

Original Research. Contributors: usage as they were unaware of its availability and the reason for not using the mouth is its improper fitting.

Case Presentation #1 for the American Board of Craniofacial Pain July 2013

Temporomandibular Joint Disorders

Up Date on TMD WHAT IS TMD? Temporomandibular Disorders (TMD)*: Donald Nixdorf DDS, MS

Outline. Limiting your risk when treating patients with TMD. Temporomandibular Disorders 20/01/2014. TMD diagnosis. Condylar position and TMD risk

5. Which word refers to making

Ear Exam and Hearing Tests

A Method for Stabilizing a Lingual Fixed Retainer in Place Prior to Bonding


OCCLUSION AND ARTICULATION IN BRUXISM AND BRUXOMANIA INVESTIGATED WITH THE SYSTEM T-SCAN III

OPTION I TEST REVIEW

Hearing Aids. Bernycia Askew

Dental JOURNAL of A d v a n c e S t u d i e s

College of Medicine Dept. of Medical physics Physics of ear and hearing /CH

Shadeguides Finding the Centric Relation The Kois Deprogrammer

A SURVEY TO ASSESS PATIENT SATISFACTION AFTER RECEIVING COMPLETE DENTURE PROSTHESES IN A.B. SHETTY MEMORIAL INSTITUTE OF DENTAL SCIENCES

3M Center for Hearing Conservation

IQ IMPLANTS Smart Choice PRODUCT C ATA L O G

Concepts of occlusion Balanced occlusion. Monoplane occlusion. Lingualized occlusion. Figure (10-1)

External Skeletal Fixation (ESF)

9.3 Sound The frequency of sound Frequency and pitch pitch Most sound has more than one frequency The frequency spectrum

Full mouth occlusal rehabilitation; by Pankey Mann Schuyler philosophy

Powerful Capability Incredible Simplicity

Evaluation of Relation between Bizygomatic Width and Mesiodistal Dimension of Maxillary Central Incisor in Indian Population: An In Vivo Study

Analysis of TMJ joint vibration with and without silicon splints in patients with temporomandibular joint hypermobility a clinical study

Reference to primary publication Properties of alginates in ZWP 4/2014 Xantalgin Crono - Introduction

FUNCTIONAL APPLIANCES

Audiology (Clinical Applications)

Transcription:

Received: 8th August 2013 Accepted: 27th December 2013 Conflict of Interest: None Source of Support: Nil Original Research Modified stethoscope for auscultation of temporomandibular joint sounds Sanjiv Rajender Singh Dagar1, Viral Turakiya2, Ashok J Pakhan3, Nitin Jaggi4, Amit Kalra5, Vidya Vaidya6 Contributors: 1 Reader, Department of Prosthodontics, Maharana Pratap College of Dentistry & Research Center, Gwalior, Madhya Pradesh, India; 2Reader, Department of Periodontics & Implantology, Maharana Pratap College of Dentistry & Research Center, Gwalior, Madhya Pradesh, India; 3Dean, Sharad Pawar Dental College & Hospital, Sawangi, Wardha, Maharashtra, India; 4Professor & Head, Department of Oral & Maxillofacial Surgery, Maharana Pratap College of Dentistry & Research Center, Gwalior, Madhya Pradesh, India; 5Professor & Head, Department of Orthodontics & Dento-facial Orthopaedics, Maharana Pratap College of Dentistry & Research Center, Gwalior, Madhya Pradesh, India; 6Professor, Department of Prosthodontics, Maitri College of Dentistry & Research Center, Durg, Chattisgarh, India. Correspondence: Dr. Sanjiv Rajender Singh Dagar. F-45, The Palms, Plot No. 13B, Sector-6, Dwarka, New Delhi 110075, India. Phone: +91 9881474282. Email: sanjivdagar_55@yahoo.co.in How to cite the article: Dagar SR, Turakiya V, Pakhan AJ, Jaggi N, Kalra A, Vaidya V. Modified stethoscope for auscultation of temporomandibular joint sounds. J Int Oral Health 2014;6(2):40-4. Abstract: Background: Purpose of this study was to modify the stethoscope which can auscultate the temporomandibular joint (TMJ) sounds more precisely than conventional stethoscope, and fabrication of stethoscope compatible software which analyses the auscultated sound and gives documentary evidence of that analysis in the form of graph. Materials & Methods: The conventional stethoscope was modified by attaching a custom made soundscope with a recording device which can be placed in external auditory meatus (EAM) for auscultation of TMJ sounds. When this small and smooth end of custom made soundscope of modified stethoscope is placed in EAM & connected with specially developed software it records the TMJ sounds & analyzes them in form of graph. Results: Fabrication of modified stethoscope with software records the auscultated sound as a sound wave in form of graph and analyses this sound wave graph to give graphic evidence of prominent intensity at prominent frequency as spectrum analysis graph, and duration of that sound as a sound length graph. Conclusion: The use of modified stethoscope with software increases the accuracy of auscultation of TMJ sounds without any patient s discomfort and helps in diagnosis of TMJ disorders. The modified stethoscope with software for auscultation of TMJ sounds results in more precise auscultation & analysis of TMJ for sounds even of low intensity & frequency. Key Words: Bell, sound wave, soundscope, spectrum analysis, thud Introduction Mechanism of mastication is extremely complex. It is made up primarily of muscles, joints and teeth. The temporo mandibular joint (TMJ) is most complex component of masticatory system and its disorders are very common. One of the characteristic features of many patients with TMJ disorders is joint sounds. A widely used method for joint sound detection is stethoscope auscultation. Leknius & Kenyon stated that the external auditory meatus (EAM) is closest anatomically approachable structure to the TMJ, and the auditory canal has been shown to be more sensitive than surface of the skin when evaluating joint sounds.1 Taking this into consideration the present research was planned. Figure 1: Conventional Stethoscope. Materials and Methods The Stethoscope: It consists of bell chestpiece with membrane, Y- tubing and eartips. The stiffer the membrane, the higher its natural frequency of oscillation and the more efficient it is at higher frequencies. It also gives resonance to bell and the resonance of the bell amplifies the sound. The short length of tube can maximize high frequencies and still not be too short. However, 15 40

found that 4.6 mm is even better.2 The greatest impairment in the efficiency of a stethoscope is the air leak. Room noise due to air leaks tends to mask high frequencies more than low once. Fabrication of modified stethoscope 1) A stethoscope was obtained (Microtone; M. R. surgical co. India) [Figure 1]. 2) Stainless steel, soundscope 18 mm in length and 10 mm in diameter was fabricated3 [Figure 2]. 3) The soundscope consist of a metal tube (A), stiff membrane (B), threaded metal cap (C) [Figure 3] 4) Controlling unit consisting of recording device (5mm in diameter), and multimedia cord was fabricated [Figure 4]. 5) A 6 feet multimedia cord was soldered to recording device at one end; the free end of wire cord was passed through soundscope whereas the recording device was fitted in soundscope [Figure 5]. 6) A stiff, 8 mm diameter membrane was cut & placed on recording device in soundscope to tighten with a threaded metal cap.3 7) The bell of stethoscope was removed along with its 30 mm long metal connector from Y-tubing and the screw that joins the bell to the metal connector was loosened. The free end of wire cord was passed Figure 2: Soundscope. inches is a good compromise between the ideal of 12 inches and the usual length of 20 to 22 inches that are commercially available. Reflected waves in the tubing may amplify sounds. Therefore, different tubing lengths may amplify different frequencies. The thicker the tube, the better is the elimination of room noise. A vinyl tube has been found to be better than rubber for this purpose. Very narrow tubes carry low frequencies best and wide tubing carries high frequencies best. An internal diameter of 3 mm was once recommended as the ideal compromise for carrying both frequencies. However, it has recently been Figure 3: Metal tube (A), Stiff membrane (B) and Metal cap (C). Figure 4: Controlling Unit, Recording Device & multimedia Cord. Figure 6: Modified Stethoscope Figure 5: Recording device fitted in soundscope. 41

through metal connector. Then the threaded end of metal connector was inserted into the soundscope and rotated until it was fully tightened. This whole unit was then inserted in the Y-tubing & the free end of wire cord was taken out through this at Y junction to connect with controlling unit [Figure 6]. Fabrication of software Temporomandibular joint sound analyser software was developed by software engineer & was synchronized with modified stethoscope through controlling unit by means of multimedia cord. Method of auscultation for TMJ sounds The patient was asked to sit on dental chair in upright & relaxed position. The modified stethoscope was connected with software through connecting device by means of cord. The smooth end of the soundscope was placed into the external auditory meatus [Figure 7], after starting the software patient was asked to open his mouth slowly up to maximum opening followed by mouth closer with same speed up to maximum intercuspation to auscultate the TMJ sound if any. This records the TMJ sound if present in the form of wave graph [Figure 8]. In this way both TMJ were auscultated. Analysis of TMJ sounds The recorded sounds were analyzed by using tools of temporomandibular joint sound analyzer software to obtained graphs of: 1. Spectrum analysis of frequency in Hz on X-axis verses intensity in db (decibel) on Y-axis which gives the prominent intensity in db at prominent frequency in Hz [Figure 9]. 2. Sound length in milliseconds (ms), which gives duration in ms for which that sound, occurs [Figure 10]. Figure 7: Auscultation of TMJ by modified stethoscope. Figure 8: Sound wave graph. 42

Figure 9: Spectrum analysis graph. Figure 10: Sound length graph. Discussion It is realistic to assume that the more complex a system is the greater the likelihood that breakdown will occur. It is remarkable to think that in most instances it functions without major complications for the lifetime of the individual. When breakdown does occur, however, it can produce a situation as complicated as the system itself 4 There are various commercial instruments like stethoscope, pressure algometers, sound/vibration detection devices and jaw tracking devices etc. that claim to aid in the diagnosis of various temporomandibular joint disorders. The modified stethoscope with software auscultates, records and analyzes the TMJ sounds for prominent frequency and intensity with sound length. The studies previously cited indicate that the ability to detect the presence of TMJ sounds varies from poor to excellent, depending on the technique used. The severity and nature of the click may vary from patient to patient and even within different sides in the same patient. It was documented that quantitative and qualitative analysis of the joint sounds and vibrations allows clinicians to better differentiate abnormal joints from normal joints. Each specific disease of the TMJ was characterized by a unique relationship between the sounds propagated by the joint and the movement.5 There are three types of joint sounds: a) Crepitus This is a grating or scraping noise that occurs on jaw movement which can be noticed by the patient and often can be palpated by the clinician. It is said by the patient to feel like sand paper rubbing together. It is caused by roughened, irregular articular surfaces of the osteoarthritic joint. b) Clicking This is sharp & short sound caused by uncoordinated movement of condylar head and TMJ disc. c) Thud This is dull & long sound caused by friction of two soft or wet surfaces. Units of Sound The standard measuring units of sound are: hertz (Hz) & decibel (db). Hertz is the measure of the frequency of oscillations in a wave motion. The name of the unit, hertz refers to the 43

German scientist Rudolf Hertz, who first proved the propagation of radio waves in 1879. The frequency is 1 Hz when one oscillation occurs in one second. When 1000 oscillations occur in one second, the frequency is 1000 Hz, or 1 khz (kilohertz). The frequency of audible sound ranges from lowest of 16 Hz to highest frequency of 20 khz. Sounds higher than 20 khz are called ultrasounds, while sounds below 16 Hz are called infrasounds. In our TMJ sound analyser the frequency of sound in Hz is on Xaxis of sound wave graph. Decibel (db) is the proportional unit of sound intensity, and the intensity of sound is sound pressure in Pascals at a given frequency in Hz. The lowest sound audible with a normal (average) hearing is 0 db. A person with good hearing can hear even weaker sounds (-5 db). In this TMJ sound analyser the intensity of sound in db is on Y-axis of sound wave graph. By comparing the obtained graphs the difference between clicking & crepitus can be observed. The clicking sound represents a sharp line with short sound length & less frequency. Whereas the crepitus type of sound represents comparatively thicker line with longer sound length & higher frequency on sound wave graph. The third term used to denote type of sound was thud, which represents a thickest line with longest sound length & highest frequency on sound wave graph. Conclusion The TMJ is the only joint which is directly related to the dentistry. The signs and symptoms of temporomandibular disorders are extremely common findings. Some of these appear as significant symptoms that motivate the patient to seek treatment. Many, however, are subtle and not even at a level of clinical awareness by the patient. Some subclinical signs can later become apparent and represent more significant functional disturbances if left unattended. It is therefore extremely important that each sign & symptom should be identified by means of a thorough history & examination procedure. This modified stethoscope along with software is very helpful diagnostic tool for diagnosis of TMJ disorders. Fabrication of modified stethoscope with software for auscultation of TMJ sounds results in more precise auscultation of TMJ for sounds even of low intensity & frequency. The software records the auscultated sound as a sound wave graph and analyses this sound wave graph to give graphic evidence of prominent intensity at prominent frequency as spectrum analysis graph, and duration of that sound as a sound length graph. The use of modified stethoscope with software increases the accuracy of auscultation of TMJ sounds without any patient s discomfort and helps in diagnosis of TMJ disorders. References 1. Leknius C, Kenyon BJ. Simple instrument for auscultation of temporomandibular joint sounds. J Prosthet Dent 2004;92:604. 2. Jules C. Bedside cardiology, 5th ed. Philadelphia, USA: Lippincott Williams & Wilkins; 1999. p. 119-22. 3. Dagar SR, Pakhan AJ, Thombare RU, Bhoyar A. Modified instrument for auscultation of temporomandibular joint sounds. J Indian Posthodont Soc 2006;6(1):29-32. 4. Okeson JP. Management of temporomandibular disorders and occlusion. 2nd ed, St. Louis:Mosby, Inc.; 1989. p. 173-206. 5. Baba K, Tsukiyama Y, Yamazak M, Clark GT. A review of temporomandibular disorder diagnostic techniques. J Prosthet Dent 2001;86:184-94. 44