Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

Similar documents
The Journey of Cyberknife Commissioning

STEREOTACTIC DOSE VERIFICATION PHANTOM VERSATILE STEREOTACTIC QA PHANTOMS

4 Essentials of CK Physics 8/2/2012. SRS using the CyberKnife. Disclaimer/Conflict of Interest

CyberKnife Technology in Ablative Radiation Therapy. Jun Yang PhD Cyberknife Center of Philadelphia Drexel University Jan 2017

Unrivaled, End-to-End

EORTC Member Facility Questionnaire

SRS Uncertainty: Linac and CyberKnife Uncertainties

Out-of-field doses of CyberKnife in stereotactic radiotherapy of prostate cancer patients

ph fax

Patient-specific quality assurance for intracranial cases in robotic radiosurgery system

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Stereotactic Body Radiotherapy for Lung Lesions using the CyberKnife of-the-art and New Innovations

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

Can we hit the target? Can we put the dose where we want it? Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy

Indiana University Health Proton Therapy Center. Chee-Wai Cheng, Ph.D.

02 CyberKnife: Treatment Delivery

Learning Objectives. Clinically operating proton therapy facilities. Overview of Quality Assurance in Proton Therapy. Omar Zeidan

Quality assurance in external radiotherapy

Film-based dose validation of Monte Carlo algorithm for Cyberknife system with a CIRS thorax phantom

S. Derreumaux (IRSN) Accidents in radiation therapy in France: causes, consequences and lessons learned

Volumetric Modulated Arc Therapy - Patient Specific QA

Mania Aspradakis John Byrne Hugo Palmans John Conway Jim Warrington Karen Rosser Simon Duane

Assessment of Dosimetric Functions of An Equinox 100 Telecobalt Machine

Quality assurance and credentialing requirements for sites using inverse planned IMRT Techniques

ARCCHECK: COMPREHENSIVE EVALUATION OF THE DIODE ARRAY PHANTOM - RULES OF THUMB FOR PHANTOM USE FOR QA. By Vibha Chaswal, Ph.D.

Delivery Quality Assurance with a High Resolution Liquid Filled Ion Chamber Array for Robotic Radiosurgery

PGY-1. Resident Review Session Schedule

Small field diode dosimetry

Amendment No. 2. Item No. 2 (Rfx/ Event number )

Patient and Linac QA - present and the future

Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program?

Eric E. Klein, Ph.D. Chair of TG-142

Varian Edge Experience. Jinkoo Kim, Ph.D Henry Ford Health System

7/31/2012. Volumetric modulated arc therapy. UAB Department of Radiation Oncology. Richard Popple, Ph.D.

S Y N C H R O N Y R E S P I R A T O R Y T R A C K I N G S Y S T E M

Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film

X-Ray Guided Robotic Radiosurgery for Solid Tumors

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

Hot Topics in SRS: Small Field Dosimetry & Other Treatment Uncertainties. Sonja Dieterich, PhD University of California Davis

MVCT Image. Robert Staton, PhD DABR. MD Anderson Cancer Center Orlando. ACMP Annual Meeting 2011

PRECISE, ROBOTIC TREATMENT AS INDIVIDUAL AS EVERY PATIENT

Dosisverifikation mit Delta 4 Discover während der Behandlung

IMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)

typical IMRT fraction time and expand high definition radiotherapy anywhere in the body with the widest range of motion of the

8/2/2018. Disclosures. In ICRU91: SRT = {SBRT/SABR, SRS}

Cyberknife Stereotactic Treatment

IMRT QA: Point Dose Measurements or 2D Array?

Limits of Precision and Accuracy of Radiation Delivery Systems

Canadian Partnership for Quality Radiotherapy. Technical Quality Control Guidelines for Gamma Knife Radiosurgery. A guidance document on behalf of:

3D Pre-treatment Dose Verification for Stereotactic Body Radiation Therapy Patients

Introduction of RapidArc TM : an example of commissioning and implementing a QA programme for a new technology

Credentialing for the Use of IGRT in Clinical Trials

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

Leila E. A. Nichol Royal Surrey County Hospital

The CyberKnife Robotic Radiosurgery System in 2010

Imaging of Scattered Radiation for Real Time Tracking of Tumor Motion During Lung SBRT

Albert Lisbona Medical Physics Department CLCC Nantes Atlantique a

Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification

SBRT REQUIRES: STEREOTACTIC BODY RADIOTHERAPY STEREOTACTIC BODY RADIOTHERAPY (SBRT) (SBRT) What s s in a name? Stereotactic Body Radiotherapy

Stereotactic Radiosurgery. Extracranial Stereotactic Radiosurgery. Linear accelerators. Basic technique. Indications of SRS

02 CyberKnife: System Overview

Quality Assurance of Ultrasound Imaging in Radiation Therapy. Zuofeng Li, D.Sc. Murty S. Goddu, Ph.D. Washington University St.

Data Collected During Audits for Clinical Trials. July 21, 2010 Geoffrey S. Ibbott, Ph.D. and RPC Staff

Calibration of dosimeters for small mega voltage photon fields at ARPANSA

XSIGHT LUNG TRACKING SYSTEM

Topics covered 7/21/2014. Radiation Dosimetry for Proton Therapy

Intensity Modulated RadioTherapy

Assessing Heterogeneity Correction Algorithms Using the Radiological Physics Center Anthropomorphic Thorax Phantom

ABSTRACTS FOR RADIOTHERAPY STANDARDS USERS MEETING. 5 th June 2007

An Independent Audit and Analysis of Small Field Dosimetry Quality Assurance. David Followill IROC Houston QA Center

Additional Questions for Review 2D & 3D

Monte Carlo for CyberKnife Incise TM MLC

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT

Quality Assurance in Stereotactic. Radiotherapy. Swedish Cancer Institute Seattle, WA

Assessment of a three-dimensional (3D) water scanning system for beam commissioning and measurements on a helical tomotherapy unit

Basic dosimetric data for treatment planning system

AAPM Task Group 180 Image Guidance Doses Delivered During Radiotherapy: Quantification, Management, and Reduction

Quality Assurance in Radiation Therapy

Dose rate response of Digital Megavolt Imager detector for flattening filter-free beams

Stereotaxy. Outlines. Establishing SBRT Program: Physics & Dosimetry. SBRT - Simulation. Body Localizer. Sim. Sim. Sim. Stereotaxy?

SHIELDING TECHNIQUES FOR CURRENT RADIATION THERAPY MODALITIES

Online Care, Online Control, Online Confidence

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

tsmall FIELD DOSE CALIBRATIONS WITH GAFCHROMIC FILM

D DAVID PUBLISHING. Uncertainties of in vivo Dosimetry Using Semiconductors. I. Introduction. 2. Methodology

A new geometric and mechanical verification device for medical LINACs

SRS/SBRT Errors and Causes

Practical Reference Dosimetry Course April 2015 PRDC Program, at a glance. Version 1.0. Day 1 Day 2 Day 3 Day 4

Radiosurgery. Most Important! 8/2/2012. Stereotactic Radiosurgery: State of the Art Technology and Implementation Linear Accelerator Radiosurgery

DOSIMETRIC COMPARISION FOR RADIATION QUALITY IN HIGH ENERGY PHOTON BEAMS

Evaluation of Dosimetric Characteristics of a Double-focused Dynamic Micro-Multileaf Collimator (DMLC)

CHAPTER 5. STUDY OF ANGULAR RESPONSE OF asi 1000 EPID AND IMATRIXX 2-D ARRAY SYSTEM FOR IMRT PATIENT SPECIFIC QA

IGRT1 technologies. Paweł Kukołowicz Warsaw, Poland

Quality Assurance of TPS: comparison of dose calculation for stereotactic patients in Eclipse and iplan RT Dose

IBA Dosimetry Company Presentation. Patient Safety & Quality Control

Computed tomography Acceptance testing and dose measurements

Small field dosimetry, an example of what a Medical Physicist does (& some more examples) A/PROF SCOTT CROWE MEDICAL PHYSICIST

Proton Stereotactic Radiotherapy: Clinical Overview. Brian Winey, Ph.D. Physicist, MGH Assistant Professor, HMS

Verification of Relative Output Factor (ROF) Measurement for Radiosurgery Small Photon Beams

Future upcoming technologies and what audit needs to address

Transcription:

Clinical Implementation of the CyberKnife Disclosure I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past. Mary Ellen Masterson-McGary McGary CyberKnife Centers of Tampa Bay Outline Machine Overview Site planning Commissioning Ongoing QA QA Equipment User Accuray Other vendors Machine Overview 1

Design features X-ray tubes 6 MV linac (w/o flattener) mounted on an industrial robot with 6 degrees of freedom of motion and 0.2 mm precision Synchrony camera Linear accelerator Robot 1200 to > 5000 possible angles of beam incidence around the patient non-coplanar, non-isocentric Image guidance system that tracks, detects and corrects for patient motion and organ motion throughout treatment Treatment Couch Image detectors SRS and SBRT anywhere in the body IMAGE GUIDANCE SYSTEM & ROBOTIC DELIVERY SYSTEM Tracking Modes Fiducial tracking Lesion motion not affected by respiration Lesion motion affected by respiration Density tracking Skull tracking Spine tracking Lung nodule tracking 2

Collimators: fixed and motorized Site Planning Iris has same 12 aperture sizes as the fixed collimators: 5, 7.5, 10, 12.5, 15, 20, 25, 30, 35, 40, 50, 60 mm diameter. Shielding Typical CK Layout All walls are primary barriers Consider shielding entire roof same as the walls Don t use old workload numbers: output (mu/min) is going up and treatment times are going down every day; use newest data available 3

CK in a Conventional Linac Vault Commissioning Commissioning Data Collection Commissioning Data Collection Goal Measurements Estimated Time Goal Measurements Estimated Time Laser alignment Beam data collection for ray tracing algorithm Verify coincidence of alignment of laser and center of radiation field TPR for each fixed and mobile collimator diameter OCR for each collimator size at depths = 15, 50, 100, 200, and 300 mm OF at three SAD s for each collimator size 1 2 hours 30 hours for fixed collimators 36 hours for variable aperture collimator Additional beam data collection for Monte Carlo algorithm In-air OF at 800 mm SAD for all field sizes Beam profile with secondary collimator removed at 800 mm SSD at depth slightly greater than dmax PDD (d = 0 to 300 mm) for the 60 mm collimator at 800 mm SSD 4 hours for the fixed collimators 3 hour for the variable aperture collimator Accuray provides cumulative data from all other centers with same model CyberKnife for comparison with your data. 4

Commissioning Data Collection Commissioning MultiPlan TPS Goal Scanner evaluation Measurements Scan appropriate phantom(s) on all CT scanners that will be used for treatment planning Determine CT number density relationship Confirm geometric accuracy of scanners Confirm accuracy of MultiPlan fusion Estimated Time 8 hours per scanner Goal Validate beam data Ray tracing algorithm verification Measurements Comparison of measured and reference beam data Many end-to to-end tests (comprehensive system tests) to verify accuracy of absolute dose delivery and relative dose distribution in high and low dose regions Use all collimators, conformal and isocentric plans, all tracking modes. Estimated Time 2 hours 1-22 weeks Commissioning MultiPlan TPS (Monte Carlo) Commissioning MultiPlan TPS Goal Generate a source model Compare measured data Generate normalization factor Measurements Calculation of energy spectrum, source distribution, and fluence distribution. Calculate and compare the measured and calculated TPR s and OCR s s for each collimator The NF converts deposited energy into absorbed dose. (Normalizes the calculated OF s at 800 mm to the measured OFs.) Estimated Time 5 minute calc time plus time to review and approve 5 10 days calculation time (6 8 hours physicist interaction) 2 days computation time Goal Confirm consistency between independent mu calculation software and MultiPlan Measurements Compare results under idealized single beam geometry for every collimator setting. Compare results for plans for most common disease sites, including isocentric and conformal plans, small and large collimators, homogeneous and heterogeneous cases. Resolve all discrepancies. Estimated Time 3 days 5

Commissioning: it ain t over til IMHO you are not done until you have independent extra-mural confirmation of your system s s accuracy. E.g. the MDACC SRS phantom (and other relevant MDACC/RPC phantom tests) Routine Quality Assurance Do not treat until you have an independent report that confirms that your system meets standard dosimetric criteria. Ongoing QA Daily Monthly Quarterly Annual Com/UG Safety Interlocks Check System Status Check LINAC Output Constancy Test Robot Perch Position Laser Check X-ray Tube Warm-up AQA Test Beam Parameter Check Energy Symmetry Robot Targeting Visual Check Monthly End-to-end Targeting Tests Imaging Alignment Patient Specific QA Couch Position Accuracy Check LINAC laser Mechanical Alignment Target Locating System Quarterly Radiation Safety Report LINAC Annual Robot Calibration Safety System CT Scanner Distance Treatment Delivery Dose Verification TPS Single-Beam (PDD, OCR) 6

Patient-Specific QA Ensure that treatment plan generated is delivered Objectives Check dosimetry (absolute dose) Verify spatial distribution of dose in region to be treated and in regions to be spared Dosimetry approaches Amorphous silicon EPID is not an option for CK Film-based dosimetry is one possible approach Ion chamber measurement for absolute dose Stereotactic diode array is another possible approach Equipment Equipment: user supplied Farmer chambers (2) Electrometer Diodes SRS ion chamber (TG-51 caveats) Water scanner Small water phantom CT-electron density phantom Patient specific QA phantom CT (MR) geometric accuracy phantom kv imaging QA phantom Phantom for physics output, symmetry, flatness checks Phantom for patient-specific QA Film scanner (professional quality) Equipment: vendor supplied 7

Birdcage AQA Phantom Adaptation of Winston-Lutz test Phantom contains spherical target and fiducials for tracking Orthogonal radio-chromic films inside phantom CT scan phantom, create a plan with 2 beams: AP and lateral Treat phantom every morning < 10 minutes Analyze films daily spatial accuracy, robot calibration Accuray also supplies film analysis software. End to End Tests: Fiducial Tracking, Skull Tracking, Spine Tracking QA Respiratory Tracking Accuray also supplies film analysis software. 8

Other Accuray Supplied Equipment Pinhole laser collimator Isopost Mechanical distance indicator Software for analysis of radiochromic film tests Motion phantom with fiducials Motion phantom for 4-D 4 D planning and treatment Valuable Equipment from Other Vendors Note: The next slides are meant to serve as examples only. There are many vendors with test equipment that will do the job as well or better! Valuable Equipment from Other Vendors CyberKnife QA equipment developed at the University of Miami Accepts many different detectors Efficient measurements of symmetry, flatness, output constancy, energy Commercially available from Ricardo Garcia* Valuable Equipment from Other Vendors Blue phantom from Standard Imaging Accepts many different detectors Can use film and i.c. simultaneously Includes inhomogeneities Patient specific QA * address available upon request 9

Simultaneous Film & IC Use commercially available water-equivalent equivalent phantom Achieve film and ion chamber dose measurements in one phantom with different slabs Ion chamber slab has a cavity which accommodates inter- changeable ion chamber plugs for absolute dose measurements Film slabs allow multiple films to be positioned for dose profile measurements Patient-Specific Dosimetry: Example Stereotactic Dose Verification Phantom from Standard Imaging A16 ion chamber EBT film FilmQA analysis software Example results (prostate case): Absolute dose error 1.9% Dose distribution measured vs calculated excellent Example: Dose Distribution (Isolines( Isolines) Valuable Equipment from Other Vendors kv imaging test module from Standard Imaging Angled at 45 degrees for CK geometry High contrast resolution constancy Relative density constancy Geometric distortion Artifacts 10

Valuable Equipment from Other Vendors ISIS phantom manufactured by TGM 2 geometric accuracy of CT/MR/PET-CT systems accuracy of MP fusion constancy of CT number-electron electron density relationship 4D CT and CK tracking? Valuable Equipment from Other Vendors SRS Profiler manufactured by Sun Nuclear Corp. Uses MapCheck software Constancy of flatness symmetry, output calibration, laser-radiation radiation field coincidence, commissioning??? SNC cylindrical diode array being evaluated for CK patient-specific dosimetry Coming soon Task Group 135 QA for Robotic Radiosurgery Sonja Dieterich,, Chair estimated completion: 12/31/09 Conclusion The CyberKnife has unique features that affect site planning, acceptance testing, commissioning, and ongoing quality assurance. Specialized equipment is needed for some measurements. Adequate time is needed for physics work in order to assure that your system functions safely and accurately. Independent verification of absolute dose accuracy and relative dose distribution is essential before treating patients. 11

Epilogue: Don t t Get Discouraged Gaining an in-depth understanding of and confidence in - the unique CyberKnife hardware and software is necessary, challenging, rewarding, and fun. Investing time in site planning, commissioning, and clinical implementation is necessary, challenging, rewarding, and fun. When the novelty of the new technology begins to wear off after a year or two, the clinical outcomes you will see will keep the excitement going and going and going.. 12