TECHNICAL REPORT on the disinfection systems in dental unit water lines.

Similar documents
Savina Ditommaso *, Monica Giacomuzzi, Elisa Ricciardi and Carla M. Zotti

In-Use Evaluation Report

Commercial in Confidence

Disinfection of respirators with the KR2000 Keredusy

SurgiCube Clinical Tests

16026 University Oak, San Antonio, TX 78249

FIT TECHNICAL DATA. Summary of Research Studies and Production Trials

State of Kuwait Ministry of Health Infection Control Directorate. Infection control Guidelines at Physiotherapy-Hydrotherapy

MICROBIOLOGICAL PROFILE

Policy Title: Single-Use (Disposable) Devices Policy Number: 13. Effective Date: 6/10/2013 Review Date: 6/10/2016

Concentrate Appearance: colourless liquid * at 20 C miscible with water in any proportion Density: g/cm 3 *

SCOPE AND FIELD OF APPLICATION

The Whitley Internal HEPA filtration system bacteriological testing

Legionella pneumophila SG1 Kit for the CellStream

INTRODUCTION. OGGETTO: Certificazione Sistema Autosteril (Castellini, Cefla Dental Group, Imola)

Legionella pneumophila SG1 Kit for the CellStream

EFFICACY TESTS (EN 1276) VIRUSOLVE + AMITY UK LTD HOSPITAL INFECTION RESEARCH LABORATORY CITY HOSPITAL NHS TRUST DUDLEY ROAD BIRMINGHAM B18 7QH

Biomarkers into saliva

Avoid contaminated water and prevent growth of biofilm

Biofilms: Álvaro Pascual MD, PhD Department of Microbiology

AZOWIPE CLINICAL EFFICACY DATA

AMENDATORY SECTION (Amending WSR , filed 10/10/95, effective 11/10/95)

Naturally derived Alcohol free Proven efficiency

Literature Review and Recommendations: Management of Dental Unit Waterlines

A COMPREHENSIVE SYSTEM FOR THE PREVENTION OF LEGIONELLOSIS IN A HOSPITAL

Audit of monitoring of the quality of water used in preparation of dialysis fluid in Scotland in 2010

Scope of Accreditation of Testing Laboratory (EN ISO/IEC 17025:2005) HygCen Austria GmbH / (ID No.: 0196)

Total Legionella Control TLC The Industry Standard

Biological Consulting Services of North Florida, Inc.

Duygu Perçin 1, Gülin Güler 2

MICROBIOLOGICAL PROFILE

QUAT 256 Disinfectant Cleaner Deodorizer Mildewstat Fungicide Virucide*

Environmental Monitoring How to Satisfy the Regulator. Presented by Tanja Varglien, July 2017

Principles and Practices of Asepsis

Bactisure Wound Lavage. Advancing Biofilm Removal

Biological Consulting Services of North Florida, Inc.

Norovirus Surrogate Test Exposure to SixLog s ihp TM (ionized Hydrogen Peroxide) Decontamination Technology. Executive Summary:

Survival of antibiotic resistant Pseudomonas strains in different types of water

OZONE EFFECTS ON SPECIFIC BACTERIA AND VIRUSES (

Charles P. Gerba Departments of Soil, Water and Environmental Science and Epidemiology and Environmental Health University of Arizona Tucson, AZ

PRINCIPLES AND PRACTICES OF ASEPSIS OBJECTIVES

3/26/2014 OBJECTIVES PRINCIPLES AND PRACTICES OF ASEPSIS DEFINING ASEPSIS MEDICAL ASEPSIS PRINCIPLES OF MEDICAL ASEPSIS

PRESENTER: DENNIS NYACHAE MOSE KENYATTA UNIVERSITY

MATERIAL SAFETY DATA SHEET

Deb InstantGEL Complete. Summary of Microbiological Test Data ISSUE 2

Environmental Monitoring, risk assessment and responsibilities

TOUCAN DATA & SCIENCE INFORMATION

APIC IC Challenges in Dialysis Danilo B. Concepcion,CBNT, CCHT-A Operations Manager, Renal Service

Cleaning and Disinfection of Environmental Surfaces

Establishing a High Quality Infection Control and Safety Program

Microbiological Summary

Clean Water. Clear Choice.

2 Codex Standard

Sanosil Disinfectants Hospital Hygiene

Environmental Infection Control General Directorate for Infection Prevention and Control Section: Dental

N. O. Sanli-Yurudu A. Kimiran-Erdem. E. O. Arslan-Aydogdu Z. Zeybek S. Gurun. Keywords Legionella pneumophila Biocide Cooling tower

Time allowed: 2 hours Answer ALL questions in Section A, ALL PARTS of the question in Section B and ONE question from Section C.

Evaluation of the feasibility of the VACUETTE Urine CCM tube for microbial testing of urine samples

UNDERSTANDING YOUR WATER PROFILE PRESENTED BY POULTRY PARTNERS AND AHPD

Schedule. This laboratory has demonstrated its technical competence to operate in accordance with MS ISO/IEC 17025:2005 (ISO/IEC 17025:2005).

The reprocessing of medical devices in Dentistry. Are there any differences to the reprocessing of surgical instruments?

Dental Asepsis. Dental Water Asepsis: Rationale, Challenges, and Infection Control Strategies. Author:

ANNEX III ASEAN GUIDELINES ON LIMITS OF CONTAMINANTS FOR TRADITIONAL MEDICINES

Guideline on the management of Legionella cases, incidents, outbreaks and clusters in the community Quick Reference Guide

Evaluation of Low Temperature Depuration for Reducing Vibrio parahaemolyticus in Oysters

The effect of disinfectant agents in eliminating the contamination of dental unit water Özcan, Mutlu; Kulak, Y; Kazazoglu, E

Partners Biofilm Remover

Evaluation of Antibacterial Effect of Odor Eliminating Compounds

Preparation Instructions for the CAMLOG /CONELOG Implant System

ULTRA & GABARDINO 20/20 LARGE Silpure treatment ANTIBACTERIAL

pneumophila Bactericidal Effect of Calcium Oxide and Calcined Shell Calcium on Legionella

INHIBITION OF STAPHYLOCOCCUS AUREUS IN SWEET WHEY

MEASUREMENT OF THE DEGREE OF PROTECTION AFFORDED BY RESPIRATORY PROTECTIVE EQUIPMENT AGAINST MICROBIOLOGICAL AEROSOLS

Synergism between hydrogen peroxide and seventeen acids against six bacterial strains

Effect of 70% alcohol swabbing and flushing technique on high speed contra angle toward bacterial count and identification of pathogens

Laboratory assessment of physical and chemical methods of preserving urine specimens

Show me the evidence! Water can cause infection and illness if hospital water systems are not properly engineered and managed 6/29/2017

This house believes that infrared taps should be removed from healthcare premises in Wales

The Puzzle of OSHA Compliance and Infection Control in the Dental Laboratory. The Puzzle of OSHA Compliance in the Dental Laboratory

Hygienic Reprocessing

Bacteriological quality evaluation of bedpans in a university hospital

International Journal of Public Health Dentistry

A Legionellosis Intervention Timeline, treatments and efficacy of treatments

The integrity of pharmaceutical and nutritional packaging

Data Requirements Efficacy Data for FSIS, USDA, FDA

Changing face of infection control: Dental unit water lines

ISO INTERNATIONAL STANDARD. Anaesthetic and respiratory equipment Nebulizing systems and components

Whisper 7054 Foam Hand Sanitiser

Surface Disinfection & Equipment Asepsis FCDH Unit Setup & Cleanup Chemical Surface Disinfectants Waterlines

Legionella. A detailed insight from our specialists. Overview Lifecycle How it manifests Strains and species Facts and statistics

Development of ISO 11731:2017. Simon in t Veld Manager Microbiology Vitens Laboratorium Convenor ISO TC7/SC4/WG10 Legionella

METRICIDE OPA PLUS SOLUTION. Technical Bulletin

Polytechnic, Bauchi, Nigeria Corresponding author.

Review. Management of dental unit waterline biofilms in the 21st century. Future Microbiology

Presented by: Dustin Crumby, RN BSN MBA

Evaluation of Caries Activity by ORATEST

Draft of Sanitation Standards for General Foods

Overview. Protect Your Business Against. Poultry & Poultry Processing Industry. Unique molecular bonding technology. and viruses

Transcription:

TECHNICAL REPORT on the disinfection systems in dental unit water lines. Part I. Microbiological field tests Purpose: checking the hygienic quality of the water delivered by a Cefla Dental Group dental unit, equipped with both continuous disinfection (MWB) and non-continuous disinfection (AUTOSTERIL) systems. In the period February-May 2013, we tested the effectiveness of the continuous sanitisation system with 550 ppm of H2O2 (Peroxy Ag+) installed on a dental unit of the Cefla Dental Group supplied to the Dental School of Turin. The test dental unit, like all the other units at the Dental School, at the end of each work day was submitted to a disinfection cycle with H2O2 (Peroxy Ag+) at 3%. The treatment was performed in the morning in case of downtime due to holidays or weekend breaks. During work on patients, the dental unit would deliver tap water mixed with hydrogen peroxide at the final concentration of 550 ppm H2O2. The tests on the effectiveness of the sanitising system were not carried out by testing for Legionella, as the microbial loads detected at the Dental School (and systematically measured by this Department) were not such as to allow for anti-microbial effectiveness measurements; therefore, tests were performed on other microbial indicators (Pseudomonas spp, P. aeruginosa and total bacterial count at 22 and 37 C). All samplings were carried out in the morning and submitted to monitoring for three months, with sampling every 15 days.

The test results, listed in the report dated 10 th June 2013, show that in none of the test runs bacterial contamination was detected - except for the first (basal) test performed after installation and in the absence of sanitisation treatments. Turin, 3 rd August 2014 The Lab Manager Prof. Carla Zotti The Test Manager Dr. Savina Ditommaso

Turin, 10 th June 2013 RE: scientific validation results regarding the continuous disinfecting system for inlet water to the Cefla Dental Group dental unit. Following our earlier agreements and contract entered into by the Cefla Company, the Dental School and the Hygiene Applied Serology and Microbiology Laboratory of the University of Turin, tests were carried out on water samples taken from the dental unit, in order to evaluate the continuous disinfecting system (600 ppm of H2O2) for inlet water to the dental unit. The tested parameters were: a) Total Bacterial Count (TBC) at 22 and 37 C c) Pseudomonas spp d) Pseudomonas aeruginosa The tests were performed according to the reference standards: UNI EN ISO 6222 and UNI EN 12780 Monitoring was performed for 3 months, and samplings were repeated every fifteen days using outlet water from the syringe and turbine of the tested dental unit. The results of the microbiological tests (expressed in Colony Forming Units, CFUs) are shown in the table below:

Sampling date: TBC at 22 C TBC at 37 C Pseudomonas spp P. aeruginosa Basal (2/2/ 2013) >300 CFU/ml >300 CFU/ml >300 CFU/250 ml >300 CFU/250 ml 26/02/2013 12/03/2013 26/03/2013 08/04/2013 22/04/2013 07/05/2013 21/05/2013 Except for the first (basal) sampling, none of the tested samples during testing showed any microbiological contamination (no detected bacteria in the tested volume) and Pseudomonas aeruginosa was equally undetected. The Lab Manager Prof. Carla Zotti The Test Manager Dr. Savina Ditommaso

TECHNICAL REPORT on the disinfection systems in dental unit water lines. Part II. Microbiological tests on prototype Purpose: Validate continuous disinfection of inlet water to the dental unit on the device simulator (CEFLA Dental Group). On the test bench prototype developed by CEFLA and installed at DSSPP tests were performed on the pathogen Legionella pneumophila sg. 1 (ATCC 33152) to determine the effectiveness of the Peroxy Ag + disinfectant at the concentration of 540 ± 10 ppm of H2O2. The tests on water samples taken from the continuous disinfection device simulator were carried out by experimentally contaminating the device with Legionella in order to evaluate the dental unit inlet water sanitising system. The test results are shown in the report dated 13 th November 2013, and suggest that, in the samples taken from effluents after contact times of 7 minutes and 10 minutes, the 99.99% = 4 log reduction prescribed by the EN standards to be able to claim the bactericidal activity of the solution used had not been achieved. In the sample taken after 60 minutes of hold time, a decrease >= 4 log was observed (reduction >= 99.99% of the inoculum). Therefore, the obtained field results (report dated 10 th June 2013) are possibly attributable not to the continuous system exclusively, but to the synergic action resulting from the protocol applied at the Dental School (treatment at 3% and continuous treatment).

It is possible, but yet to be demonstrated, that the continuous system ensures the persistent presence of disinfectant, but the only way of evaluating the actual efficacy of the concentration used (540 +- 10 ppm of H2O2) in the absence of 3% treatment would be testing the dental unit in the absence of such treatment. The continuous system alone at the concentration of 540 ± 10 ppm of H2O2 can help maintain, during one-hour activity pauses, a decrease >= 99.99% of any present Legionella loads. Turin, 3 rd August 2014 The Lab Manager Prof. Carla Zotti The Test Manager Dr. Savina Ditommaso

Tax Code 80088230018 VAT IT02099550010 Hygiene Applied Serology and Microbiology Laboratory Turin, 13 th November 2013 RE: results of the scientific validation of the continuous disinfecting system Simulator for inlet water to the Cefla Dental Group dental unit Following our earlier agreements and contract entered into by the Cefla Company, the Dental School and the Hygiene Applied Serology and Microbiology Laboratory of the University of Turin, tests were carried out on water samples taken from the continuous disinfection device Simulator, experimentally contaminated with Legionella pneumophila sg 1, in order to evaluate the sanitising system (540 ±10 ppm of H2O2) for dental unit inlet water. The tests were performed using as a reference standard EN 13623 (2010). Test conditions: Inoculum: Legionella pneumophila sg 1 (ATCC 33152) Diluent: hard water (HW) Ambient temperature (approximately 22 C) Test product: 540 ±10 ppm of Peroxy Ag+ (H2O2 3%) Neutraliser: 0.25 g/l catalase Effluent sampling times: 7 min., 10 min., 60 min. Test performance time: 10 th September - 4 th October Calculation of results: log10 = log10 inoculum log10 sample.

Tax Code 80088230018 VAT IT02099550010 Hygiene Applied Serology and Microbiology Laboratory Before performing the test on the Simulator, neutralisation method validation tests were carried out (by filtration, mixed neutraliser, neutraliser with catalase). The test results showed that the most suitable method for Peroxy neutralisation is neutralisation with 0.25 g/l catalase. Test results: Flow sampling after 7 min contact time: log10 <1 Flow Sampling after 10 min contact time: log10 <1 Sampling after 60 min hold time: log10 4 Conclusion: On the basis of the obtained results the test product Peroxy Ag+, at a concentration of 540 ±10 ppm, showed bactericidal activity against Legionella pneumophila sg 1 only after a contact time of 60 minutes. The Test Manager Dr. Savina Ditommaso