Understanding aneurysms and flow diversion treatment

Similar documents
Neuroform Microdelivery Stent System

AXS Catalyst Distal Access Catheter

Introducing a New Treatment Method for Brain Aneurysms

Single Pass MCA Revascularization with Trevo

DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service

Pipeline Embolization Device

The SplitWire Percutaneous Transluminal Angioplasty Scoring Device. Instructions for Use

Neuroform EZ Stent System

1 Comparison of Warfarin and Aspirin for Symptomatic Intracranial Arterial Stenosis. N Engl J Med 352;13, March 31, 2005

Introduction 3. What is Peripheral Vascular Disease? 5. What Are Some of the Symptoms of Peripheral Vascular Disease? 6

Assurant Cobalt Iliac BALLOON EXPANDABLE STENT SYSTEM

Introduction What Causes Peripheral Vascular Disease? How Do Doctors Treat Peripheral Vascular Disease?... 9

REBEL. Platinum Chromium Coronary Stent System. Patient Information Guide

Detection & Treatments

What You Should Know About Cerebral Aneurysms

Patient Information Booklet

Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter

System.

ER REBOA Catheter. Instructions for Use

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

Understanding Peripheral

NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER

Instructions for Use Cordis PRECISE PRO Rx Nitinol Stent System

Cerebral Aneurysms. U.S. DEPARTMENT OF HEALTH AND HUMAN SERVICES Public Health Service National Institutes of Health

Flow-diverting stents (in the Treatment of intracranial aneurysms)

Talent Abdominal Stent Graft

WallFlex Biliary RX Partially Covered Stent System Prescriptive Information

LVIS Intraluminal Stent Device: Separates itself from other stents used in treatments for aneurysm with recent PMA FDA approval

Patient Brochure. Clearstream Technologies, Ltd. Moyne Upper Enniscorthy Co. Wexford, Ireland. PK Rev. 0 05/17

A PATIENT`S GUIDE TO CORONARY ARTERY DISEASE. AND YOUR NIRxcell CoCr CORONARY Stent on RX System

From the Cerebrovascular Imaging and Intervention Committee of the American Heart Association Cardiovascular Council

RECOMMENDED INSTRUCTIONS FOR USE

WHITE PAPER: A GUIDE TO UNDERSTANDING SUBARACHNOID HEMORRHAGE

Quality Metrics. Stroke Related Procedure Outcomes

SURPASS FLOW DIVERTER

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE Medical technology guidance SCOPE Pipeline embolisation device for the treatment of

Ruby Coil. Large Volume Detachable Coils

Advanced Innovation for Exceptional Performance

DURABLE. CONSISTENT. SAFE. IN.PACT Admiral Drug-Coated Balloon

YES. Your Guide to Getting WATCHMAN. Is a life without blood thinners possible?

E X P L A I N I N G STROKE

WEB device for treating brain (intracranial) aneurysms

ANGIOPLASTY AND STENTING

PIPELINE FLEX EMBOLIZATION DEVICE CODING AND REIMBURSEMENT GUIDE

Aneurysm Embolization: Coiling, Stenting, & Flow Diversion

TCD AND VASOSPASM SAH

What you should know about your diagnosis of incontinence

Case Report 1. CTA head. (c) Tele3D Advantage, LLC

Studying Aneurysm Devices in the Intracranial Neurovasculature

Comparison of Five Major Recent Endovascular Treatment Trials

COIL SYSTEM ORDERING INFORMATION

Patient guide: pfm Nit-Occlud PDA coil occlusion system. Catheter occlusion of. Patent Ductus Arteriosus. with the

ENDOVASCULAR THERAPIES FOR ACUTE STROKE

Repair of Intracranial Vessel Perforation with Onyx-18 Using an Exovascular Retreating Catheter Technique

Peel-Apart Percutaneous Introducer Kits for

Promus ELITE. Everolimus-Eluting Platinum Chromium Coronary Stent System. Patient Information Guide CV01

INSTRUCTIONS FOR USE

Instructions for Use io-flex Probe

Cordis S.M.A.R.T. and S.M.A.R.T. CONTROL Nitinol System For the Iliac Arteries

Aneurysm Embolization: Coiling

PTA Balloon Dilatation Catheter

Kadlec Regional Medical Center Cardiac Electrophysiology WATCHMAN Left Atrial Appendage Closure Device

Patient Information. Peripheral Arterial Disease and the Lutonix 035 Balloon. Advancing Lives and the Delivery of Health Care

Carotid Artery Stenting

National Hospital for Neurology and Neurosurgery

Balloon in Balloon (BIB )

Overview

PTA Balloon Dilatation Catheter

Computed Tomographic Angiography (CTA)

Azur CX 35 Peripheral Coil System (Detachable) Instructions for Use

Subclavian artery Stenting

Procedures commonly seen at Vanderbilt Medical Center PACU s: Cervical, thoracic, lumbar, and sacral spine surgeries. Goes to 6N

Directions For Use. All directions should be read before use

PATIENT BOOKLET. Medtronic Transcatheter Aortic Valve Replacement (TAVR) System. medtronic.com/tavr

Report of Flow Diverter Clinical Trials in Japan

Abdominal Exam: The examination of the abdomen used by physicians to detect an abdominal aortic aneurysm.

Coronary angioplasty and stents

Carotid Artery Stenting

A PATIENT S GUIDE TO THE LEFT ATRIAL APPENDAGE CLOSURE. Reducing the risk of stroke in atrial fibrillation

NIH Public Access Author Manuscript J Am Coll Radiol. Author manuscript; available in PMC 2013 June 24.

AXIOS Stent and Delivery System

Stroke 101. Maine Cardiovascular Health Summit. Eileen Hawkins, RN, MSN, CNRN Pen Bay Stroke Program Coordinator November 7, 2013

Peripheral Intravascular Lithotripsy (IVL) Catheter Instructions for Use (IFU)

TRAUMATIC CAROTID &VERTEBRAL ARTERY INJURIES

WATCHMAN Left Atrial Appendage Closure Device

CORONARY ANGIOPLASTY

Patient Information. Atrial Septal Defect (ASD) Repair

What Is an Arteriovenous malformation (AVM)?

SCAI Fall Fellows Course Subclavian/Innominate Case Presentation

SHARED DECISION MAKING: AN EVIDENCE-BASED CORNERSTONE OF LAAC THERAPY

CAROTID ARTERY ANGIOPLASTY

Transcatheter Aortic Valve Replacement

GORE EXCLUDER AAA Endoprosthesis ANNUAL CLINICAL UPDATE OCTOBER Section I Clinical experience. Section II Worldwide commercial experience

Instructions for Use 1

Trans-catheter aortic valve implantation (TAVI) work up

INL No. A0083 Project Medtronic Thoracic patients guide Description Version 18

MULTILAYER FLOW MODULATOR (MFM ) FOR PERIPHERAL ANEURYSMS TREATMENT (LOWER LIMBS, VISCERALS AND SUBCLAVIAN)

CEREBRO VASCULAR ACCIDENTS

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

PRO-DENSE Bone Graft Substitute The following languages are included in this packet:

Transcription:

Surpass Streamline Flow Diverter See package insert for complete indications, contraindications, warnings and instructions for use. INTENDED USE / INDICATIONS FOR USE The Surpass Streamline Flow Diverter is indicated for use in the endovascular treatment of patients (18 years of age and older) with unruptured large or giant saccular wide-neck (neck width 4 mm or dome-to-neck ratio < 2) or fusiform intracranial aneurysms in the internal carotid artery from the petrous segment to the terminus arising from a parent vessel with a diameter 2.5 mm and 5.3 mm. CONTRAINDICATIONS The Surpass Streamline Flow Diverter is contraindicated in the following patient types: Patients in whom the parent vessel size does not fall within the indicated range. Patients in whom antiplatelet and / or anticoagulation therapy (e.g., aspirin and clopidogrel) is contraindicated. Patients who have not received dual anti-platelet agents prior to the procedure. Patients with an active bacterial infection. Patients in whom the angiography demonstrates the anatomy is not appropriate for endovascular treatment due to conditions such as: Severe intracranial vessel tortuosity or stenosis; and/or Intracranial vasospasm not responsive to medical therapy. POTENTIAL ADVERSE EVENTS Risks that may be associated with the use of the Surpass Flow Diverter in the intracranial arteries include: Allergic reaction Adverse reaction to anesthesia, contrast or antiplatelet/ anticoagulation agents Aphasia Cardiac arrhythmia Cranial neuropathy Confusion, coma, change in mental status Death Device migration, fracture, misplacement Dissection or perforation of the parent artery Embolism (air, clots, device fragments) Groin injury (bleeding, pain, vessel/nerve damage) Headache Hemiplegia Hydrocephalus Implant or parent vessel stenosis Implant thrombosis/occlusion Infection Intracerebral bleeding Mass effect Myocardial infarction Neurological deficits Perforation or rupture of aneurysm Progressive neurologic symptoms related to intracranial aneurysm (IA) Pseudoaneurysm formation Reaction to radiation exposure (i.e., alopecia, burns ranging in severity from skin reddening to ulcers, cataracts, delayed neoplasia) Renal failure Retroperitoneal hematoma Seizure Stroke Subarachnoid hemorrhage Thromboembolism from device Thrombosis of parent artery or branch vessel Transient ischemic attack (TIA) Vasospasm Risks that are eye related with the use of the Surpass Flow Diverter may include: Amaurosis fugax/transient blindness Blindness Diplopia Reduced visual acuity/field Retinal artery occlusion Retinal ischemia Retinal infarction Vision impairment WARNINGS This device should only be used by physicians who have received appropriate training in interventional neuroradiology or interventional radiology and preclinical training on the use of this device as established by Stryker Neurovascular. Do not use if the package is opened or damaged. Persons allergic to nickel, cobalt chromium or platinum tungsten metal may suffer an allergic response to this Flow Diverter implant. The system is designed to be manipulated while under high-quality fluoroscopic observation. If resistance is met during manipulation, determine the cause of resistance before proceeding. Do not torque or rotate the system. Purge the entire Delivery System carefully to avoid the accidental introduction of air into the system. If any defects are observed with the Surpass Streamline Flow Diverter system, replace the device. If excessive resistance is encountered during the use of the Surpass Flow Diverter at any time during the procedure, discontinue use of the system. Movement of the system against resistance may result in damage to the vessel, a system component, or the patient. Repositioning of the Surpass Flow Diverter device in the parent vessel without fully retrieving the device is not advised since it could cause vessel damage and/or perforation. After full deployment, do not re-position. It is important for the Surpass Streamline Flow Diverter device to be used with the Stryker Neurovascular AXS Catalyst 5 Distal Access Catheter (Model UPN M003IC0581150) and one of the following compatible guidewires: Stryker Neurovascular Synchro 2 (e.g., Model UPN M00326410) or Stryker Neurovascular Synchro -14 (e.g., Model UPN M00313010) or Boston Scientific Transend EX (e.g., Model UPN M001468050) [Clinical Warning] Do not use device for ruptured intracranial aneurysms. [Clinical Warning] A decrease in effectiveness has been observed in subjects aged > 65 years old, subjects with history of smoking and history of prior non-target intracranial aneurysm treated. [Clinical Warning] Judicious patient selection is important. Patients who fall outside the therapeutic range for antiplatelet testing or at the lower limits have an increased risk of developing stent thrombosis, even with additional doses of antiplatelet medication. Another effective anti-platelet agent should be considered. [Clinical Warning] Placement of multiple Surpass Flow Diverter devices may increase the risk of ischemic complications. [Clinical Warning] Delayed aneurysm rupture may occur with large and giant intracranial aneurysms. CAUTIONS / PRECAUTIONS Experience with device implants indicates that there is a risk of stenosis. Subsequent stenosis may require dilatation of the vessel segment containing the device. The risks and long-term outcome following dilatation of endothelialized devices is unknown at present. Confirm the device labeling reflects the desired size of the target vessel where the device is to be used. Do not expose the system to organic solvents (e.g., alcohol). Appropriate anti-platelet and anti-coagulation therapy should be employed in accordance with standard medical practice. A thrombosing aneurysm may aggravate pre-existing or cause new symptoms of mass effect and may require medical therapy. Use product prior to the Use By date. Do not remove the Surpass Flow Diverter from its Delivery System. The device and Delivery System are intended to perform as a single system and must not be altered. Carefully inspect the device packaging and system prior to use. Do not use the Surpass Flow Diverter if any component appears damaged or missing. Carefully remove the tray lid and grasp the Delivery System by its RHV and hoop to facilitate removal from the tray. Select a device length that is at least 10 mm longer than the intracranial aneurysm neck to maintain a minimum of 5 mm on either side of intracranial aneurysm neck. Do not attempt to partially deploy and recapture the Surpass Flow Diverter more than three times. Use caution when crossing the deployed device with guidewires or other accessory devices. Dispose of all used devices in accordance with hospital policy for biohazardous materials. Do not attempt to move the Surpass Flow Diverter more distally once it has begun apposing to the vessel walls. Do not apply additional force if significant resistance is experienced while attempting to recapture the flow diverter. This device has not been evaluated for pediatric use. The safety and effectiveness of the device has not been established in the treatment of small and medium wide-neck intracranial aneurysms. Operators should take all necessary precautions to limit X-radiation doses to patients and themselves by using sufficient shielding, reducing fluoroscopy times, and modifying X-ray technical factors where possible. Lower intracranial aneurysm occlusion rates may be associated with giant intracranial aneurysms (> 25 mm). Do not deploy Surpass Flow Diverter devices in parallel (side by side). The Surpass Flow Diverter may create local field inhomogeneity and susceptibility artifacts during magnetic resonance angiography (MRA), which may degrade the diagnostic quality to assess effective intracranial aneurysm treatment. Contents supplied STERILE using an ethylene oxide (EO) process. Do not use if sterile barrier is damaged. If damage is found, call your Stryker Neurovascular representative. For single patient use only. Do not reuse, reprocess or resterilize. Reuse, reprocessing or resterilization may compromise the structural integrity of the device and/or lead to device failure which, in turn, may result in patient injury, illness or death. Reuse, reprocessing or resterilization may also create a risk of contamination of the device and/or cause patient infection or cross-infection, including, but not limited to, the transmission of infectious disease(s) from one patient to another. Contamination of the device may lead to injury, illness or death of the patient. After use, dispose of product and packaging in accordance with hospital administrative and/or local government policy. Legal Manufacturer Stryker Neurovascular 47900 Bayside Parkway Fremont, CA 94538 USA USA Customer Service 855-91 NEURO (916-3876) strykerneurovascular.com Understanding aneurysms and flow diversion treatment Electronic instructions for use are available at www.strykerneurovascular.com/dfu. Rx Only Copyright 2018 Stryker 2018-09 NV00026618-01D

Table of contents What is a brain aneurysm?... 1 Are all aneurysms the same?... 2 How is an aneurysm treated?... 3 What is flow diversion and how is it different?... 4 The procedure... 6 Patient information card... 7 Notes... 8 Copyright 2017 Stryker AP001500.AA Page B of 8 Copyright 2017 Stryker AP001500.AA Page B of 8

What is a brain aneurysm? A brain aneurysm is the bulging of a weakened spot on a brain artery. As blood flows within an artery over time, a weakened portion of the vessel wall may balloon or swell outward, resulting in an aneurysm. If left untreated, a blood-filled aneurysm can leak or rupture into the space around the brain, causing serious symptoms such as severe headache, nausea, vomiting, blurred or double vision, stroke and even death. Are all aneurysms the same? There are three types of aneurysms that can form. A saccular aneurysm, sometimes known as a berry aneurysm, is the most commonly seen among aneurysm patients, accounting for up to 90% of all cases. This type of aneurysm has a narrow neck, or opening from the artery. A wide-neck aneurysm is a type of saccular aneurysm with a neck that is 4mm or wider, or is at least half as wide as it is high. A fusiform aneurysm forms when swelling of both sides of an artery takes place. This type of aneurysm is less common and rarely ruptures. Aneurysms may not only differ in appearance, but they can also differ in size and location. Through imaging screening, a doctor can identify the exact nature of an aneurysm and establish the most appropriate and effective treatment plan for the patient accordingly. Page 1 of 8 Page 2 of 8

How is an aneurysm treated? Several medical procedures are available to treat aneurysms, and the appropriate treatment depends on the shape, size and location of the aneurysm. Two procedures commonly used include surgical clipping and coiling. Surgical clipping closes off the aneurysm by inserting a small metal clip across its opening, stopping the blood from flowing into it. What is flow diversion and how is it different? Flow diversion is different from clipping and coiling because it focuses treatment on the diseased part of the vessel that sustains the aneurysm, rather than on the aneurysm itself. A Flow Diverter is designed to restore the vessel wall in order to facilitate natural blood flow through the vessel and away from the aneurysm. When blood flow to an aneurysm is slowed and eventually eliminated, the aneurysm begins to shrink. Flow diversion is an especially effective treatment for aneurysms that have wide necks, are larger in size or are fusiform in shape. Coiling involves the insertion of a coil of soft platinum wire into the aneurysm, causing the blood to clot and create a seal between the artery and the aneurysm. Coiling procedures can be supported by additional devices, such as stents or balloons, to treat wide-neck aneurysms. An alternative treatment option called flow diversion is now available for certain patients as well. Page 3 of 8 Page 4 of 8

Flow diversion (continued) The Surpass Streamline Flow Diverter is a safe and effective, minimally invasive device, designed to occlude large or giant wide-neck intracranial aneurysms to prevent rupture and related neurological disability and death. Available in Europe since 2014, the Surpass Streamline Flow Diverter was approved by the FDA in 2018 after completion of the SCENT (The Surpass IntraCranial Aneurysm EmbolizatioN System Pivotal Trial to treat large or giant wide-neck aneurysms) clinical trial. The Surpass Streamline Flow Diverter is a small braided tube made from a material called cobalt chromium and is implanted adjacent to the neck of the aneurysm, allowing for restoration of the vessel wall. It can be used independently of other technologies to treat aneurysms. The procedure What happens before the procedure? Your doctor will tell you what you need to do before you are admitted to the hospital. You may be asked to take aspirin and other prescription medications before the procedure. It is important to tell your doctor if you cannot take aspirin or if you have a history of bleeding problems. A Flow Diverter being placed across the aneurysm neck. Immediately following placement of the Flow Diverter, blood flow into the aneurysm will slow and over time blood no longer enters the aneurysm as the aneurysm shrinks. Warnings and precautions The Surpass Streamline Flow Diverter has been shown to be Magnetic Resonance Imaging (MRI) conditional. This is important to know if you should need any future MRI for any part of your body. Your doctor will also need to know if you have any allergies to drugs, contrast media (X-ray dye) or certain metals like nickel. Persons allergic to contrast media (X-ray dye), nickel, cobalt chromium or platinum tungsten metal may suffer an allergic response to this Flow Diverter implant. Refer to your physician for more information. Medications such as aspirin and Plavix are required before and after treatment as instructed by your doctor. What happens during the procedure? Your catheter-based aneurysm treatment will take place in a special area in radiology or the operating room of your hospital. The treatment uses X-ray and an X-ray dye called contrast media to allow an X-ray picture of your arteries to be taken. Your doctor will put a sheath (short plastic tube) in the artery in your groin. A catheter is inserted through the sheath and threaded through the artery to the aneurysm. The delivery catheter of the Surpass Streamline Flow Diverter will be used to deliver it to the aneurysm neck. Then the Flow Diverter is released from the delivery catheter and deployed across the aneurysm sac. As the Flow Diverter is being released, it expands to lie against the inside of the artery wall. Page 5 of 8 Page 6 of 8

The procedure (continued) What happens after the procedure? After the procedure, the medical staff will monitor your heart rate and blood pressure. Your doctor will limit your activities for a few weeks and will tell you when you can return to normal activities. Your doctor may also prescribe medications to prevent blood clots from forming on the Flow Diverter or in your arteries. Your doctor will let you know how long you need to take these medications. Your doctor will schedule follow-up visits, specific for your medical condition. This may include a physical examination and imaging studies to look at the aneurysm area. Sometimes aneurysms may need to be treated again. Notes What are the potential complications? As with any surgical procedure, there are some risks associated with the implantation of the Surpass Streamline Flow Diverter. Refer to the directions for use and consult with your physician. Patient information card Your doctor will fill out a patient information card for you after the treatment. Make sure your doctor gives this to you before you leave the hospital. You should carry this card with you. It is very important to show this card to other doctors that you go to in the future. The card will explain that you have a stent in your brain. It also lets a doctor know that the stent is MRI conditional. Refer to your physician for more information. Page 7 of 8 Page 8 of 8