Characterization of Peripapillary Atrophy Using Spectral Domain Optical Coherence Tomography

Similar documents
Scanning Laser Polarimetry and Optical Coherence Tomography for Detection of Retinal Nerve Fiber Layer Defects

Retinal Nerve Fiber Layer Measurement Variability with Spectral Domain Optical Coherence Tomography

Relationship between the GDx VCC and Stratus OCT in Primary Open Angle Glaucoma

Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography

CLINICAL SCIENCES. Comparison of Glaucoma Diagnostic Capabilities of Cirrus HD and Stratus Optical Coherence Tomography

Relationship Between Structure

Diagnostic Accuracy of OCT with a Normative Database to Detect Diffuse Retinal Nerve Fiber Layer Atrophy: Diffuse Atrophy Imaging Study METHODS

Comparison of Retinal Nerve Fiber Layer Thickness between Stratus and Spectralis OCT

Seiji T. Takagi, Yoshiyuki Kita, Asuka Takeyama, and Goji Tomita. 1. Introduction. 2. Subjects and Methods

Retinal nerve fiber layer thickness in Indian eyes with optical coherence tomography

Comparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements

Translating data and measurements from stratus to cirrus OCT in glaucoma patients and healthy subjects

RETINAL NERVE FIBER LAYER

STRUCTURE & FUNCTION An Integrated Approach for the Detection and Follow-up of Glaucoma. Module 3a GDx

OtticaFisiopatologica

Optical coherence tomography (OCT) is a noninvasive,

Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma

Method for comparing visual field defects to local RNFL and RGC damage seen on frequency domain OCT in patients with glaucoma.

CLINICAL SCIENCES. Felipe A. Medeiros, MD; Linda M. Zangwill, PhD; Christopher Bowd, PhD; Robert N. Weinreb, MD

Structural examina.on: Imaging

Relationship between GDx VCC and Stratus OCT in juvenile glaucoma

The Role of the RNFL in the Diagnosis of Glaucoma

Il contributo dell'angio-oct: valutazione integrata della componente nervosa e vascolare della malattia glaucomatosa

EXPERIMENTAL AND THERAPEUTIC MEDICINE 6: , 2013

Analysis of Peripapillary Atrophy Using Spectral Domain Optical Coherence Tomography

Glaucoma: Diagnostic Modalities

A Formula to Predict Spectral Domain Optical Coherence Tomography (OCT) Retinal Nerve Fiber Layer Measurements Based on Time Domain OCT Measurements

Measurement of Choroidal Thickness in Normal Eyes Using 3D OCT-1000 Spectral Domain Optical Coherence Tomography

Ganglion cell complex scan in the early prediction of glaucoma

Study of Retinal Nerve Fiber Layer Thickness Within Normal Hemivisual Field in Primary Open-Angle Glaucoma and Normal-Tension Glaucoma

NIH Public Access Author Manuscript Br J Ophthalmol. Author manuscript; available in PMC 2010 April 29.

Comparison of Optic Disc Topography Measured by Retinal Thickness Analyzer with Measurement by Heidelberg Retina Tomograph II

OCT in the Diagnosis and Follow-up of Glaucoma

Noel de Jesus Atienza, MD, MSc and Joseph Anthony Tumbocon, MD

Peripapillary Retinal Thickness. Maps in the Evaluation of Glaucoma Patients: A Novel Concept.

Ability of Scanning Laser Polarimetry (GDx) to Discriminate among Early Glaucomatous, Ocular Hypertensive and Normal Eyes in the Korean Population

Patterns of Subsequent Progression of Localized Retinal Nerve Fiber Layer Defects on Red-free Fundus Photographs in Normal-tension Glaucoma

Advances in OCT Murray Fingeret, OD

MATERIALS AND METHODS

CLINICAL SCIENCES. optic neuropathy characterized

Differences between Non-arteritic Anterior Ischemic Optic Neuropathy and Open Angle Glaucoma with Altitudinal Visual Field Defect

To assess the glaucoma diagnostic ability of Fourier Domain Optical Coherence Tomography

Investigation of the relationship between central corneal thickness and retinal nerve fiber layer thickness in ocular hypertension

The Effect of Pupil Dilation on Scanning Laser Polarimetry With Variable Corneal Compensation

-Zone Parapapillary Atrophy and the Rate of Retinal Nerve Fiber Layer Thinning in Glaucoma

Clinical Use of OCT in Assessing Glaucoma Progression

Reproducibility of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Optical Coherence Tomography

Factors Associated With Visual Field Progression in Cirrus Optical Coherence Tomography-guided Progression Analysis: A Topographic Approach

International Journal of Scientific & Engineering Research, Volume 4, Issue 12, December ISSN

Scanning Laser Tomography to Evaluate Optic Discs of Normal Eyes

S Morishita, T Tanabe, S Yu, M Hangai, T Ojima, H Aikawa, N Yoshimura. Clinical science

MEDICAL POLICY. Proprietary Information of YourCare Healthcare

Position of retinal blood vessels correlates with retinal nerve fibre layer thickness profiles as measured with GDx VCC and ECC

Beyond the C/D Ratio: Evaluating a Glaucomatous Optic Nerve. Marcus Gonzales, OD, FAAO Cedar Springs Eye Clinic COPE ID#: GL

Optical Coherence Tomograpic Features in Idiopathic Retinitis, Vasculitis, Aneurysms and Neuroretinitis (IRVAN)

Available online at Pelagia Research Library. Advances in Applied Science Research, 2013, 4(6):

MEDICAL POLICY. Proprietary Information of Excellus Health Plan, Inc. A nonprofit independent licensee of the BlueCross BlueShield Association

Sensitivity and specificity of new GDx parameters Colen TP, Tang NEML, Mulder PGH and Lemij HG Submitted for publication CHAPTER 7

Reproducibility of Nerve Fiber Layer Thickness Measurements by Use of Optical Coherence Tomography

* Şükrü Bayraktar, MD, Zerrin Bayraktar, MD, and Ömer Faruk Yilmaz, MD

OPTOMETRY RESEARCH PAPER

THE BASIC PATHOLOGIC CHANGE IN GLAUCOMA IS

The Measure of Confidence

The evaluation of the optic nerve and retinal nerve

Evaluation of retinal nerve fiber layer thickness parameters in myopic population using scanning laser polarimetry (GDxVCC)

Cirrus TM HD-OCT. Details defi ne your decisions

C a t a r a c t G l a u c o m a R e t i n a R e f r a c t i v e. The GDxVCC Early answers and ongoing assessment for glaucoma

Introduction. Hemma Resch, Gabor Deak, Ivania Pereira and Clemens Vass. e225. Acta Ophthalmologica 2012

Relationship between Scanning Laser Polarimetry with Enhanced Corneal Compensation and with Variable Corneal Compensation

Clinical decision making based on data from GDx: One year observations

Changes in Peripapillary Retinal Nerve Fiber Layer Thickness after Pattern Scanning Laser Photocoagulation in Patients with Diabetic Retinopathy

Linking structure and function in glaucoma

Corporate Medical Policy

Science & Technologies

Repeatability and Reproducibility of Macular Thickness Measurements Using Fourier Domain Optical Coherence Tomography

R&M Solutions

Confocal Adaptive Optics Imaging of Peripapillary Nerve Fiber Bundles: Implications for Glaucomatous Damage Seen on Circumpapillary OCT Scans

Cirrus TM HD-OCT. Details define your decisions

Early Detection Of Glaucoma Clinical Clues. Points To Live By. Glaucoma Risk Factors 10/3/2014

Comparison of macular GCIPL and peripapillary RNFL deviation maps for detection of glaucomatous eye with localized RNFL defect

Performance of time-domain and spectral-domain Optical Coherence Tomography for glaucoma screening

Research Article The Pattern of Retinal Nerve Fiber Layer and Macular Ganglion Cell-Inner Plexiform Layer Thickness Changes in Glaucoma

Generally, myopia is a condition of the eye that makes it

Reproducibility of measurements and variability of the classification algorithm of Stratus OCT in normal, hypertensive, and glaucomatous patients

Although measurements of the optic disc and retinal nerve

Advances in the Structural Evaluation of Glaucoma with Optical Coherence Tomography

Influence of Myopic Disc Shape on the Diagnostic Precision of the Heidelberg Retina Tomograph

Scanning Laser Polarimetry in Patients with Acute Attack of Primary Angle Closure

Key words: Glaucoma, Imaging, Ophthalmoscopy, Optic neuropathy, Topography

Scanning laser polarimetry (SLP) incorporates a confocal

Ophthalmology Department, Lozano Blesa University Hospital, c/ San Juan Bosco 15, Zaragoza, Spain 2

The Optic Nerve Head In Glaucoma. Clinical Pearl #1. Characteristics of Normal Disk 9/26/2017. Initial detectable damage Structure vs function

A comparison of HRT II and GDx imaging for glaucoma detection in a primary care eye clinic setting

A Review Of Risk Factors. Early Detection Of Glaucoma Clinical Clues. A risk factor analysis is critical. Points To Live By

Diagnostic Accuracy of Scanning Laser Polarimetry with Enhanced versus Variable Corneal Compensation

The evaluation of retinal nerve fiber layer in pigment dispersion syndrome and pigmentary glaucoma using scanning laser polarimetry

Intro to Glaucoma/2006

Detection of Glaucoma Using Scanning Laser Polarimetry with Enhanced Corneal Compensation

From the Massachusetts Eye and Ear Infirmary, Glaucoma Service, Harvard Medical School, Department of Ophthalmology, Boston, Massachusetts.

Imaging of the optic disc and retinal nerve fiber layer: the effects of age, optic disc area, refractive error, and gender

Transcription:

pissn: 1011-8942 eissn: 2092-9382 Korean J Ophthalmol 2010;24(6):353-359 DOI: 10.3341/kjo.2010.24.6.353 Characterization of Peripapillary trophy Using Spectral Domain Optical Coherence Tomography Original rticle Jung Hwa Na, yung Gil Moon, Kyung Rim Sung, Youngrok Lee, Michael S. Kook Department of Ophthalmology, san Medical Center, University of Ulsan College of Medicine, Seoul, Korea Purpose: To characterize the features of peripapillary atrophy (PP), as imaged by spectral-domain optical coherence tomography (SD-OCT). Methods: SD-OCT imaging of the optic disc was performed on healthy eyes, eyes suspected of having glaucoma, and eyes diagnosed with glaucoma. From the peripheral β-zone, the retinal nerve fiber layer (RNFL), the junction of the inner and outer segments (IS/OS) of the photoreceptor layer, and the ruch s membrane/retinal pigment epithelium complex layer (RL) were visualized. Results: Nineteen consecutive eyes of 10 subjects were imaged. The RNFL was observed in the PP β-zone of all eyes, and no eye showed an IS/OS complex in the β-zone. The RL was absent in the β-zone of two eyes. The RL was incomplete or showed posterior bowing in the β-zone of five eyes. Conclusions: The common findings in the PP β-zone were that the RNFL was present, but the photoreceptor layer was absent. Presence of the RL was variable in the β-zone areas. Key Words: ruch s membrane, Glaucoma, Peripapillary atrophy, Retinal nerve fiber layer, Spectral-domain optical coherence tomography Received: March 15, 2010 ccepted: ugust 13, 2010 Reprint requests to Kyung Rim Sung. Department of Ophthalmology, san Medical Center, #388-1 Pungnap 2-dong, Songpa-gu, Seoul 138-736, Korea. Tel: 82-2-3010-3680, Fax: 82-2-2-470-6440, E-mail: sungeye @gmail.com Structural change precedes irreversible functional decay in glaucomatous eyes [1,2]. Therefore, detection of structural changes has been emphasized for early glaucoma diagnosis. Traditionally, glaucoma structural diagnosis has been focused on the optic disc and the peripapillary retinal nerve fiber layer (RNFL). Objective and quantitative assessment of the optic disc and the peripapillary RNFL is useful both in glaucoma diagnosis and monitoring of disease progression [3-7]. Optical coherence tomography (OCT) is a noninvasive imaging modality, which can quantitatively assess both the optic disc and the RNFL. In both optic disc and RNFL evaluation, the fundamental starting point is the delineation of the optic disc margin. Measurements of optic disc parameters, including the disc area, cup/disc ratio, and rim area, are influenced by optic disc demarcation. It is also crucial to define the disc margin prior to peripapillary RNFL assessment because, physiologically, the RNFL is thickest around the disc margin and gradually becomes thinner at distances further from the margin. Previous versions of OCT (OCT1, OCT2, and Stratus OCT) automatically defined the optic disc margin in optic disc analysis as the border between the retinal pigment epithelium (RPE)/choriocapillaries and the tissue beyond this border [8-10]. lthough Stratus OCT employs interpolation between 12 measured points of the RPE/choriocapillary edge to create a best-fit curve for the optic disc margin, rather than directly connecting the 12 points, the margin remains principally determined by reference to the RPE/choriocapillary border. This may be problematic in optic discs with peripapillary atrophy (PP). The β-zone of the PP, which is close to the disc margin, is defined as an area devoid of RPE or where the RPE is atrophied with visible large choroidal vessels and sclera [11]. PP can be seen in both healthy and glaucomatous eyes but is known to be more frequent and severe in glaucomatous eyes [11-13]. Some studies have reported that an increase in the PP area can be an indicator of glaucoma progression [14,15]. Thus, PP is not rare in glaucoma patients, although PP size can vary. The recently introduced spectral domain OCT (SD-OCT) offers higher resolution and a faster scan speed than that of- c 2010 The Korean Ophthalmological Society This is an Open ccess article distributed under the terms of the Creative Commons ttribution Non-Commercial License (http://creativecommons.org/licenses /by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. 353

Korean J Ophthalmol Vol.24, No.6, 2010 fered by previous instruments. One commercially-available SD-OCT, the Spectralis OCT (Heidelberg Engineering, Heidelberg, Germany) has a scan speed 100-fold faster than that offered by conventional Stratus OCT. This increased scan speed allows more data points to be collected within a short timeperiod [16]. Improved scan resolution and more data acquisition may provide a higher quality image surrounding the optic disc. Therefore, we imaged and evaluated detailed eye structures of PP patients, with particular attention focused on the peripheral β-zone among healthy eyes, glaucomatous eyes, and glaucoma-suspect eyes using SD-OCT. Materials and Methods Study participants were recruited in a consecutive manner from our glaucoma clinic at the san Medical Center, between December 2008 and January 2009. ll participants gave informed consent before enrollment. ll procedures conformed to the Declaration of Helsinki, and the study was approved by the Institutional Review oard of the san Medical Center. ll subjects underwent a complete ophthalmologic examination; visual acuity testing; the Humphrey field analyzer Swedish interactive threshold algorithm 24-2 test (Carl Zeiss Meditec Inc., Dublin, C, US); multiple intraocular pressure (IOP) measurements using Goldmann applanation tonometry; stereoscopic optic nerve photography; and Spectralis OCT, including medical, ocular, and family history. Glaucomatous eyes were defined as those with a glaucomatous visual field (VF) defect confirmed by two reliable VF examinations and by the appearance of a glaucomatous optic disc, irrespective of the level of IOP. glaucomatous optic disc was defined by increased cupping (vertical cup-disc ratio > 0.6), a difference in vertical cup-disc ratio > 0.2 between eyes, diffuse or focal neural rim thinning, hemorrhage, and RNFL defects. Glaucoma-suspect eyes were defined as those with glaucomatous optic disc test results, but showing normal VF test data. Healthy eyes were defined as those with healthy optic discs and normal VF test results. Glaucomatous VF defects were defined when eyes met at least two of the following criteria: 1) a cluster of three points with a probability of less than 5% on the pattern deviation map in at least one hemifield and including at least one point with a probability of less than 1%, or a cluster of two points with a probability less than 1%; 2) a glaucoma hemifield test result outside 99% of the age-specific normal limits; and 3) a pattern standard deviation outside 95% of the normal limit. mong subjects qualified by other inclusion criteria, patients with discernable PP, regardless of PP size on stereoscopic optic disc photography, were analyzed. PP was differentiated into PP of the peripheral α-zone, with irregular pigmentation, and PP of the central β-zone, with visible sclera and large choroidal vessels. The presence and extent of a β-zone on an optic disc photograph was independently assessed by three glaucoma experts (MSK, KRS, and JHN), and those cases agreed upon by all three experts were included in the analyses. The raster scan mode of the Spectralis OCT, which covers an area of 6 mm 6 mm, was used to acquire optic disc images. The Spectralis OCT obtains two images, using simultaneous dual laser scanning which include an infrared image in the scanning laser ophthalmoscope (SLO) mode and an OCT scan. SLO images were used as a reference for OCT scans. n online tracking system was used to correct for eye movements. three-dimensional volumetric dataset composed of 25 line scans was obtained for each subject. ll images obtained by the Spectralis OCT were reviewed and independently evaluated by two glaucoma experts (MSK and KRS). s the Spectralis OCT does not provide any scan quality score measurement, images of poor quality were subjectively excluded when over 10% of reflectance signals Fig. 1. () The optic disc image acquired in the fast optic disc mode of the Stratus optical coherence tomography (OCT). The posterior boundary of the retina was shown as a single thick hyper-reflective red-colored band, displayed in false color (black arrow). This posterior boundary has been interpreted as the complex of the retinal pigment epithelium (RPE) and the junction between the inner and outer segment (IS/OS) of photoreceptor layer. The white arrow indicates peripapillary retinal nerve fiber layer (RNFL). () Spectralis OCT images showed posterior retinal boundaries as composed of at least two layers, one thick and one thin layer. The red arrow indicates peripapillary RNFL, and the inner thinner layer has been defined as the junction between the IS/OS of the photoreceptor layer (yellow arrow), whereas the outer thicker layer has been considered to represent the ruch s membrane/rpe border (blue arrow). 354

JH Na, et al. Characterization of Peripapillary trophy Using SD-OCT Table 1. Demographics and clinical characteristics of study participants Subject no./eye Gender/age (yr) Diagnosis CV (spherical equivalent) VF MD (d) VF PSD (d) 1/right M/68 GS 20/30 (1) 0.2 1.32 2/right M/53 GS 20/20 (1.25) -0.87 1.55 2/left M/53 GS 20/20 (1.25) -1.12 1.83 3/right F/61 GS 20/30 (2.25) -0.11 1.23 3/left F/61 GS 20/30 (1.75) 0.58 1.12 4/right M/44 GS 20/20 (-6.75) 0.52 1.36 4/left M/44 GS 20/20 (-6.5) 0.98 1.42 5/right M/44 GS 20/20 (0.25) -1.89 1.33 5/left M/44 GS 20/25 (0.25) -1.58 1.35 6/right F/33 G 20/20 (-1.0) -2.69 1.98 6/left F/33 G 20/20 (-1.5) -2.17 2.11 7/right F/71 G 20/25 (0.25) -1.58 2.16 7/left F/71 GS 20/30 (0.5) -3.65 1.83 8/right M/29 G 20/20 (-7.25) -2.79 6.99 8/left M/29 G 25/20 (-6.5) -13.5 12.61 9/right M/36 GS 20/20 (-2.25) -0.78 1.25 9/left M/36 GS 25/20 (-1.75) -0.01 1.56 10/right M/57 G 20/25 (-2.0) -5.76 9.03 10/left M/57 GS 20/20 (-1.25) -1.79 1.78 CV = best corrected visual acuity; VF = visual field; MD = mean deviation; PSD = pattern standard deviation; GS = glaucoma suspect; G = glaucoma. were absent in the line data. Pharmacologic dilation was performed if the pupil was small. ll images were acquired by a single, well-trained operator (YL). Optic disc scan images acquired by the Spectralis OCT show the detailed configuration of the retinal layer posterior boundary. With the Stratus OCT, the optic disc image acquired in the fast mode, featuring 128 scans, shows the posterior boundary as a single thick hyper-reflective red-colored band, displayed in false color (Fig. 1, black arrow). This posterior boundary has been interpreted as the complex of the RPE and the junction between the inner and outer segment (IS/OS) of the photoreceptor layer. In Fig. 1, a white arrow indicates peripapillary RNFL. The Spectralis OCT images, however, show posterior retinal boundaries composed of at least two layers, including one thinner and one thicker layer (Fig. 1). In Fig. 1, the red arrow indicates peripapillary RNFL, and the inner thinner layer has been defined as the junction between the IS/OS of the photoreceptor layer (yellow arrow), whereas the outer thicker layer has been considered to represent the ruch s membrane/rpe border (blue arrow) [17]. Due to these difficulties in interpretation, each of two glaucoma specialists (MSK and KRS) independently evaluated the detailed features of the posterior boundaries and RNFLs in PP β-zones of eyes with healthy, glaucoma-suspect, and glaucomatous optic discs imaged by the Spectralis OCT. The evaluation of the PP β -zones was performed along the multiple straight horizontal lines on the temporal sides of optic disc. We selected one representative scan line from each eye with PP. The presence or absence of various layers (RNFL, IS/OS complex, and ruch s membrane/retinal pigment epithelium complex layer [RL]) was noted. final description of the retinal layers present was obtained by consensus. Results Nineteen eyes of 10 healthy, glaucoma, and glaucomasuspect subjects, all with PP, were consecutively imaged. Demographic and clinical characteristics of participants are described in Table 1. RNFLs were observed in the β-zones of all PP eyes. IS/OS complexes were absent from the PP β -zone areas of all eyes. RLs could not be seen in the PP β -zones of two eyes. RLs were atrophic and showed posterior bowing in the PP β-zones of five eyes. Table 2 summarizes the SD-OCT findings for each PP eye. Representative cases are presented below as examples. Case 1 68-year-old man was examined under suspicion of glaucoma. ll three glaucoma experts agreed that the subject showed a glaucomatous optic disc and accompanying PP. The extent of the β-zone (red arrow) and optic disc margin (blue arrow) was demarcated on the temporal side of optic disc (Fig. 2). PP was well visualized on the SLO images from the Spectralis OCT (Fig. 2). Cross-sectional imaging of the optic disc scanned by the Spectralis OCT showed retinal layer details at high resolution. The extent of the β-zone (red arrow) was shown in SLO and cross-sectional images of the Spectralis OCT. The RNFL (yellow arrow) and RL 355

Korean J Ophthalmol Vol.24, No.6, 2010 Table 2. Features of the peripapillary atrophy β-zone observed by spectral domain optical coherence tomography imaging of healthy, glaucoma-suspect, and glaucomatous eyes Subject no./eye Gender/age (yr) Diagnosis RNFL IS/OS complex RL owing of RL 1/right M/68 GS Y N Y N 2/right M/53 GS Y N Y N 2/left M/53 GS Y N Y N 3/right F/61 H Y N Y Y 3/left F/61 GS Y N Y N 4/right M/44 H Y N N N 4/left M/44 GS Y N N N 5/right M/44 GS Y N Y Y 5/left M/44 GS Y N Y Y 6/right F/33 G Y N Incomplete Y 6/left F/33 G Y N Incomplete Y 7/right F/71 G Y N Y N 7/left F/71 GS Y N Y N 8/right M/29 G Y N Incomplete Y 8/left M/29 G Y N Incomplete Y 9/right M/36 GS Y N Y Y 9/left M/36 GS Y N Incomplete Y 10/right M/57 G Y N Y N 10/left M/57 GS Y N Y N RNFL=retinal nerve fiber layer; IS/OS=inner and outer segment of photoreceptor; RL=ruch s membrane/retinal pigment epithelium complex layer; GS=glaucoma suspect; G=glaucoma; H=healthy; Y=yes; N=no. Fig. 2. () Showed the extent of the β-zone (red arrow) and optic disc margin (blue arrow) demarcated on the temporal side of a glaucomatous optic disc. () Peripapillary atrophy (PP) was visualized on scanning laser ophthalmoscope (SLO) images from the Spectralis optical coherence tomography (OCT). (C) The extent of the β-zone (red arrow) was described in SLO and cross-sectional images of the Spectralis OCT. The retinal nerve fiber layer (yellow arrow) and ruch s membrane/retinal pigment epithelium complex layer (RL) (green arrow) were easily seen in the β-zone of OCT PP images. The RL was intact around the optic disc margin and showed hyper-reflectance. However, the inner and outer segment complexes (pink arrow) were absent from the β-zone of the PP area. C 356

JH Na, et al. Characterization of Peripapillary trophy Using SD-OCT C D Fig. 3. () Showed the extent of the β-zone (red arrow) and optic disc margin (blue arrow) on the temporal side of a healthy optic disc. () Peripapillary atrophy (PP) was well-visualized by Spectralis optical coherence tomography (OCT) scanning laser ophthalmoscope imaging. (C) In a cross-sectional image of the optic disc scanned by the Spectralis OCT, the retinal nerve fiber layer (yellow arrow) and ruch s membrane/retinal pigment epithelium complex layer (RL) (green arrow) were observed in the β-zone PP area, whereas the inner and outer segment complexes (pink arrow) were absent. The RL edge showed slight posterior bowing around the optic disc margin. (D) The Stratus OCT image also showed slight posterior bowing of the RL (white arrow), and the automatic disc margin detection algorithm failed to detect the edge of the optic disc margin (black arrow). (green arrow) were easily seen in the β-zone of the OCT PP images. The RL was intact around the optic disc margin and showed hyper-reflectance. However, the IS/OS complexes (pink arrow) were absent from the β-zone of the PP area (Fig. 2C). Case 2 61-year-old woman with a healthy optic disc showed PP on the temporal side and the extent of the β-zone (red arrow) and optic disc margin (blue arrow) was indicated on the temporal side of optic disc (Fig. 3). PP was well-visualized by Spectralis OCT SLO imaging (Fig. 3). In a cross-sectional image of the optic disc scanned by the Spectralis OCT, the RNFL (yellow arrow) and RL (green arrow) were observed in the β-zone PP area, whereas the IS/OS complexes (pink arrow) were absent. The RL was intact and showed strong reflectance, but the RL edge showed slight posterior bowing around the optic disc margin (Fig. 3C). The Spectralis OCT image and the image obtained from the Stratus OCT fast optic disc mode were compared. The Stratus OCT image also showed slight posterior bowing of the RL (white arrow), but the automatic disc margin detection algorithm failed to detect the edge (Fig. 3D, black arrow). Case 3 29-year-old man was examined under suspicion of glaucoma. Examination of the optic disc revealed advanced cupping, multiple RNFL bundle defects, and marked PP in fundus photography (Fig. 4). The extent of the β-zone (red arrow) and optic disc margin (blue arrow) was shown on the temporal side of the optic disc (Fig. 4). PP and RNFL bundle defects were also seen on Spectralis OCT SLO imaging (Fig. 4). In a cross-sectional image of the optic disc obtained by the Spectralis OCT, the RNFL was thinner when the scan line passed through the RNFL bundle defect area (Fig. 4, green scan line), but the RNFL (yellow arrow) was nonetheless observed in the β-zone of PP. The IS/OS complexes (pink arrow) were absent from the β-zone of the PP area. The RL was atrophic and posteriorly bowed in the β 357

Korean J Ophthalmol Vol.24, No.6, 2010 Fig. 4. () Showed the extent of the β-zone (red arrow) and optic disc margin (blue arrow) on the temporal side of a glaucomatous optic disc. () Peripapillary atrophy (PP) and retinal nerve fiber layer (RNFL) bundle defects were also seen on Spectralis optical coherence tomography (OCT) scanning laser ophthalmoscope imaging. In a cross-sectional image of the optic disc obtained by Spectralis OCT, the RNFL was thinner when the scan line passed through the RNFL bundle defect area (green scan line in ), but RNFL (yellow arrow) was observed in the β-zone of PP. Inner and outer segment complexes (pink arrow) were absent from the β-zone of the PP area. The ruch s membrane/retinal pigment epithelium complex layer was atrophic and posteriorly bowed in the β-zone of the PP area (C). C -zone of the PP area (Fig. 4C). Discussion When using Stratus OCT to examine optic discs, we sometimes find that disc margin detection is inappropriate and this (if uncorrected) may lead to unreliable optic disc parameter measurements. This may be one reason why OCT optic disc analysis has been less frequently used in both research and clinical settings, as compared to RNFL analysis. Inappropriate automatic disc margin determination by Stratus OCT may be explained in two ways. First, although Stratus OCT employs an RPE/choriocapillary edge detection algorithm to determine the optic disc margin, we have demonstrated that the RPE/choriocapillary edge may not be an accurate disc margin marker in optic discs with PP [8-10]. Second, the poor scan quality around the disc margin afforded by OCT may contribute to errors in optic disc margin detection. In the vicinity of the optic disc, ocular structure is very complex. This may result in difficulties in image delineation. The fast optic disc mode of the Stratus OCT instrument makes only 128 scans in each optic disc pass, leading to poor image resolution. It is difficult to discern complex structures around the optic disc. Poor image quality means that RPE edge detection is unreliable. Thus, we aimed to image the complex structures of the peripapillary retinal layer, including the β-zone of PP, using high-resolution SD-OCT. The higher-quality images of SD-OCT showed that the β -zone of the PP features were not uniform in healthy and glaucomatous optic discs, or in discs of glaucoma-suspect eyes. The presence or absence of particular structures varied among PP eyes. common finding was that the IS/OS junction was not observed in the β-zones of PP eyes, usually indicating that photoreceptors are absent from the β-zone of the PP areas. The other important finding was that detectible RNFLs were observed in the β-zone of most PP areas. Thus, RNFLs were retained despite glaucoma-induced RNFL thickness reductions in the β-zone of the PP areas. We found that 12 of 19 eyes showed intact RL complexes within the β-zone of the PP areas. However, as exemplified in case 2 above, some eyes showed posterior bowing of the 358

JH Na, et al. Characterization of Peripapillary trophy Using SD-OCT ruch s membrane/rpe complex rather than a relatively linear arrangement. In such cases, the current automatic disc margin detection algorithm of the Stratus OCT may fail to demarcate disc margins with precision. s shown in case 2, automatic disc margin detection by the Stratus OCT did not include the posteriorly bowed terminus of the RL, resulting in delineation of an erroneously large disc margin. In 7 of 19 eyes, the RL was atrophic or absent within the PP β-zone. s illustrated in case 3, the RL appeared to be thinner and incomplete around the optic disc margin, and showed posterior bowing. This finding is in line with the original definition of the PP β-zone, which is an area devoid of, or atrophic for, RPE and choriocapillaries [11]. This emphasizes that the RL cannot serve as a useful disc marginal marker in PP eyes. In these situations, the Stratus OCT is prone to error when determining the optic disc margin. limitation of our study is that we did not quantitatively define the β-zone of PP areas, nor did we match such areas with OCT images. However, our primary goal was to show how the PP β-zone is presented on high-quality OCT images. Such data have never been previously reported. Furthermore, we demonstrate that retinal layer features are not uniform in the β-zone of PP areas. In conclusion, the β-zones of PP showed fine-structure variability when evaluated by SD-OCT imaging. If both PP and the disc margin are important concepts in glaucoma diagnosis, then determination of the optic disc margin needs to be customized, based on PP characteristics. pplication of automated disc margin detection software without consideration of specific PP architecture may be scientifically invalid. Conflict of Interest No potential conflict of interest relevant to this article was reported. References 1. Sommer, Katz J, Quigley H, et al. Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field loss. rch Ophthalmol 1991;109:77-83. 2. Quigley H, Katz J, Derick RJ, et al. n evaluation of optic disc and nerve fiber layer examinations in monitoring progression of early glaucoma damage. Ophthalmology 1992;99: 19-28. 3. Schuman JS, Pedut-Kloizman T, Hertzmark E, et al. Repro- ducibility of nerve fiber layer thickness measurements using optical coherence tomography. Ophthalmology 1996;103:1889-98. 4. Weinreb RN, Shakiba S, Zangwill L. Scanning laser polarimetry to measure the nerve fiber layer of normal and glaucomatous eyes. m J Ophthalmol 1995;119:627-36. 5. Medeiros F, Zangwill LM, owd C, Weinreb RN. Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and stratus OCT optical coherence tomograph for the detection of glaucoma. rch Ophthalmol 2004;122:827-37. 6. Leung CK, Chan WM, Chong KK, et al. Comparative study of retinal nerve fiber layer measurement by Stratus OCT and GDx VCC. I: correlation analysis in glaucoma. Invest Ophthalmol Vis Sci 2005;46:3214-20. 7. Kanamori, Nagai-Kusuhara, Escaño MF, et al. Comparison of confocal scanning laser ophthalmoscopy, scanning laser polarimetry and optical coherence tomography to discriminate ocular hypertension and glaucoma at an early stage. Graefes rch Clin Exp Ophthalmol 2006;244:58-68. 8. Hee MR, Izatt J, Swanson E, et al. Optical coherence tomography of the human retina. rch Ophthalmol 1995;113: 325-32. 9. Schuman JS, Hee MR, Puliafito C, et al. Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography. rch Ophthalmol 1995; 113:586-96. 10. Pieroth L, Schuman JS, Hertzmark E, et al. Evaluation of focal defects of the nerve fiber layer using optical coherence tomography. Ophthalmology 1999;106:570-9. 11. Jonas J, Naumann GO. Parapapillary chorioretinal atrophy in normal and glaucoma eyes. II. Correlations. Invest Ophthalmol Vis Sci 1989;30:919-26. 12. Jonas J, Königsreuther K, Naumann GO. Optic disc histomorphometry in normal eyes and eyes with secondary angle-closure glaucoma. II. Parapapillary region. Graefes rch Clin Exp Ophthalmol 1992;230:134-9. 13. Jonas J, Fernández MC, Naumann GO. Glaucomatous parapapillary atrophy. Occurrence and correlations. rch Ophthalmol 1992;110:214-22. 14. raie M, Sekine M, Suzuki Y, Koseki N. Factors contributing to the progression of visual field damage in eyes with normal-tension glaucoma. Ophthalmology 1994;101:1440-4. 15. Park KH, Tomita G, Liou SY, Kitazawa Y. Correlation between peripapillary atrophy and optic nerve damage in normal-tension glaucoma. Ophthalmology 1996;103:1899-906. 16. Menke MN, Dabov S, Knecht P, Sturm V. Reproducibility of retinal thickness measurements in healthy subjects using spectralis optical coherence tomography. m J Ophthalmol 2009;147:467-72. 17. Srinivasan VJ, Monson K, Wojtkowski M, et al. Characterization of outer retinal morphology with high-speed, ultrahighresolution optical coherence tomography. Invest Ophthalmol Vis Sci 2008;49:1571-9. 359