Original Research. The Effect of temperature on the strength of luting cements Patil SG et al

Similar documents
Correlation between the Strength of Glass Ionomer Cements and Their Bond Strength to Bovine Teeth

Bond strengths between composite resin and auto cure glass ionomer cement using the co-cure technique

In nitro bond strength of cements to treated teeth

Comparison of shear bond strength of aesthetic restorative materials

ORIGINAL RESEARCH. Sandhya CA Shyam Lohakare, Pushpa Vinay Hazarey ABSTRACT

Operative dentistry. Lec: 10. Zinc oxide eugenol (ZOE):

Bond Strength of Composite Resin Luting Cements to Fiber-reinforced Composite Root Canal Post

IN VITRO COMPARISON OF RETENTION AND MARGINAL LEAKAGE OF PROVISIONAL CROWNS CEMENTED WITH PROVISIONAL CEMENT ENRICHED WITH THREE DIFFERENT ADDITIVES

If you re still using a powder-liquid liner. Like VITREBOND...

Bond strength test of acrylic artificial teeth with prosthetic base

Ketac Universal Aplicap

MDJ Comparative evaluation of compressive strength Vol.:14 No.:1 2017

Comparison of Flexural Strength of two Provisional Materials Used In Fixed Prosthodontics -An in Vitro Study.

The effect of a plastic-wrapped LED light curing unit and curing distance variances on diametral tensile strength of composite resin

Article (peer-reviewed)

MDJ Evaluation the effect of eugenol containing temporary Vol.:9 No.:2 2012

Professor and Head, Department of Pedodontics, D.J. College of Dental Sciences and Research, Niwari Road, Modinagar, Uttar Pradesh, India.

EQUIA. Self-Adhesive, Bulk Fill, Rapid Restorative System

In atraumatic restorative treatment (ART), caries removal with hand excavation

ABSTRACT INTRODUCTION /jp-journals

Get in front of the 8 ball with the new Fuji VIII GP. The first auto-cure, resin reinforced glass ionomer restorative

Fuji BULK. Robust. Rapid. Remarkable.

Early Shear Bond Strength of a One-step Self-adhesive on Orthodontic Brackets

An evaluation of the hardness of flexible Denture Base Resins

Experimental and Numerical Comparison of Stresses Level between Titanium and Novel Composite Single Tooth Implant

The Influence of Some Dentin Primers on Calcium Hydroxide Lining Cement

Fuji II LC. A Perfect Choice

Shear Bond Strength of Acidic Primer, Light-Cure Glass Ionomer, Light-Cure and Self Cure Composite Adhesive Systems - An In Vitro Study

Opacity and Color Changes of Light-Cured Ideal Makoo (IDM)

Physico-mechanical properties of a nanofilled glass ionomer cement

ANALYSIS OF FLUORIDE RELEASED FROM GIC AND RMGIC IN SALIVA AND DENTINO-ENAMEL SUBSTANCE

Evaluation of Bond Strength of Silicone and Acrylic Resin Based Resilient Denture Liners Over A Period of Storage in Water.

Filling materials are used to replace missing parts of the tooth.

Remaining dentin thickness Shallow cavity depth Preparation 0.5 mm into dentin (ideal depth) Moderate cavity depth Remaining dentin over pulp of at le

Surface treatments for tooth-colored restorations

Surface Hardness Properties of Resin-Modified Glass Ionomer Cements and Polyacid-Modified Composite Resins

Repair of fractured denture bases is an

STUDY ON FILM THICKNESS OF FOUR RESIN CEMENTS

Anisotropy of Tensile Strengths of Bovine Dentin Regarding Dentinal Tubule Orientation and Location

EFFECT OF THERMOCYCLING ON THE TENSILE AND SHEAR BOND STRENGTHS OF THREE SOFT LINERS TO A DENTURE BASE RESIN

Comparison of Shear Bond Strengths of Conventional Resin Cement and Self-adhesive Resin Cement bonded to Lithium Disilicate: An in vitro Study

Howard E. Strassler, DMD University of Maryland School of Dentistry

A Comparative Study between Bond Strength of Rebonded and Recycled Orthodontic Brackets

Effect of Thickness and Recycling on Transverse Strength of Relined Acrylic Resin Denture

Immediate versus Delayed Force Application after Orthodontic Bonding; An In Vitro Study

DH220 Dental Materials

Glass-ionomer cements: Current Status and Future Trends. John Nicholson University of Greenwich

Department of Prosthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand

of Resin Composite V Gopikrishna M Abarajithan J Krithikadatta D Kandaswamy

Shear Bond Strength of Chemical and Light Cured Glass Ionomer Cements Bonded to Resin Composite

Clinical Studies of Dental Cements: III. Seven Zinc Oxide-Eugenol Cements Used for Temporarily Cementing Completed Restorations

Effect of surface treatment with commercial primers on tensile bond strength of auto-polymerizing resin to magnetic stainless steel

Dental JOURNAL of A d v a n c e S t u d i e s

Evaluating the Effect of a Sloping Shoulder and a Shoulder Bevel on the Marginal Integrity of Porcelain-Fused-to-Metal (PFM) Veneer Crowns

Original Research. Absorption of soft lining materials Kumar SK et al

RESTORATIVE MATERIALS

Fuji BULK. Rapid, Robust, Remarkable.

Surface Treatments that Demonstrate a Significant Positive Effect on the Shear Bond Strength of Repaired Resin-modified Glass Ionomer

Pelagia Research Library. Comparison of microleakage in bonded amalgam restrorations using different adhesive materials: An invitro study

Acknowledgments Introduction p. 1 Objectives p. 1 Goals p. 2 History of Dental Materials p. 3 The Oral Environment p. 4 Characteristics of the Ideal

JBR Journal of Interdisciplinary Medicine and Dental Science

SOLUBILITY OF DIFFERENT SOFT LINING MATERIALS IN DISTILLED WATER, ARTIFICIAL SALIVA AND DENTURE DISINFECTANT SOLUTION

Results:Mean microleakage score of group G1, G2 and G3 was 2.86 ± 1.43, 1.86 ± 1.65 and 2.46 ± 1.50 respectively.

International J. of Healthcare and Biomedical Research, Volume: 04, Issue: 01, October 2015, Pages 17-25

lec: Dental material dr. Aseel Mohammed Filling material

SDR has proven reliability in high C-factor cavities 2

Effect Of Joint Surface Treatment On The Flexural Strength Of Repaired Auto-Polymerized Acrylic Resin.

Clinical Evaluation of Fixed Dental Prosthesis Failures in Indian Population: An In Vivo Study

Glass Ionomer Restoratives & Cements. Glass Ionomers FLOWABLE NANO HYBRID COMPOSITE

DPI Luting Cement. DPI Restorative Cement

Is there any clinical evidence?

All Ceramic Inlays - Coming of Age

Microleakage around zirconia crowns after ultrasonic scaling around their margin

Pulpal Protection: bases, liners, sealers, caries control Module A: Basic Concepts

Dr. Abhishek Bhattacharya, Dr. Sneha Vaidya, Dr. Anil K Tomer, Dr. Panna Mangat and Dr. Afnan Ajaz Raina

IJopRD INTRODUCTION ABSTRACT MATERIALS AND METHODS /jp-journals

Australian Dental Journal

Repair Strength of Dental Amalgams

Multidisciplinary Approach in Full Mouth Rehabilitation From Ruins to Riches in Oral Health

Analysis of the properties of commercially available silicone elastomers for maxillofacial prostheses

An estimation of fluoride release from various dental restorative materials at different ph: In vitro study

how to technique How to treat a cracked, but still inact, cusp. Disadvantages. 1 Issue Full coverage crown. >>

Retention of Metal Crowns Luted to Implant Abutments of Two Different Diameters using Different Luting Agents

XP BOND IN SELF-CURE MODE USED FOR LUTING PORCELAIN RESTORATIONS:

Double-casting method for fixed prosthodontics with functionally generated path

Near-UV light detection

Glass Ionomers. Reputable, Durable, Long Lasting

2 (Cercon) Comparison of marginal fit in zirconia-based all-ceramic frameworks (cercon) made by two approaches (Direct and Wax-up scanning)

Cairo Dental Journal (24) Number (3), 457:461 September, 2008

Ketac Universal Aplicap

A Survey on the Current Trends in the Use of Different Core Buildup Materials and Luting Agents in General Dental Practice

Effect of Different Dental Materials on the Surface. Roughness of Acrylic Resin ( A comparative in vitro study )

Pulpal Protection: bases, liners, sealers, caries control Module D: Pulp capping-caries control

(etch/rinse) dentin bonding agents consist of separate steps to condition, prime, and bond.

INFLUENCE OF FOUR DIFFERENT CEMENTS ON

INFLUENCE OF HEMA CONTENT ON THE MECHANICAL AND BONDING PROPERTIES OF EXPERIMENTAL HEMA- ADDED GLASS IONOMER CEMENTS

Restoration of the worn dentition

THE EFFECTS OF MECHANICAL STRESSES ON THE COMPARATIVE MICROLEAKAGE OF TWO DIFFERENT RESTORATIVE MATERIALS

5,6 Significant improvements of the dentin bond

Original Research. Doi: /jioh

Transcription:

Received: 03 rd August 2014 Accepted: 27 th November 2014 Conflicts of Interest: None Source of Support: Nil Original Research The Effect of Temperature on Compressive and Tensile Strengths of Commonly Used Luting Cements: An In Vitro Study Suneel G Patil 1, MC Suresh Sajjan 2, Rekha Patil 3 Contributors: 1 Assistant Professor, Department of Dentistry, Karnataka Institute of Medical Sciences, Hubli, Karnataka, India; 2 Professor, Department of Prosthodontics, Vishnu Dental College, Bhimavaram, Andhra Pradesh, India, 3 Private Practice, Hubli, Karnataka, India. Correspondence: Dr. Patil SG. Department of Dentistry, Karnataka Institute of Medical Sciences, Hubli, Karnataka, India. Email: sunilpatil 2ooo@yahoo.com How to cite the article: Patil SG, Sajjan MCS, Patil R. The effect of temperature on compressive and tensile strengths of commonly used luting cements: An in vitro study. J Int Oral Health 2015;7 (2):13 19. Abstract: Background: The luting cements must withstand masticatory and parafunctional stresses in the warm and wet oral environment. Mouth temperature and the temperature of the ingested foods may induce thermal variation and plastic deformation within the cements and might affect the strength properties. The objectives of this study were to evaluate the effect of temperature on the compressive and diametral tensile strengths of two polycarboxylate, a conventional glass ionomer and a resin modified glass ionomer luting cements and, to compare the compressive strength and the diametral tensile strength of the selected luting cements at varying temperatures. Materials and Methods: In this study, standardized specimens were prepared. The temperature of the specimens was regulated prior to testing them using a universal testing machine at a crosshead speed of 1 mm/min. Six specimens each were tested at 23 C, 37 C and 50 C for both the compressive and diametral tensile strengths, for all the luting cements. Results: All the luting cements showed a marginal reduction in their compressive and diametral tensile strengths at raised temperatures. Fuji Plus was strongest in compression, followed by Fuji I > Poly F > Liv Carbo. Fuji Plus had the highest diametral tensile strength values, followed by Poly F = Fuji I = Liv Carbo, at all temperatures. Conclusion: An increase in the temperature caused no significant reduction in the compressive and diametral tensile strengths of the cements evaluated. The compressive strength of the luting cements differed significantly from one another at all temperatures. The diametral tensile strength of resin modified glass ionomers differed considerably from the other cements, whereas there was no significant between the other cements, at all the temperatures. Key Words: Compressive strength, diametral tensile strength, luting cement Introduction Dental luting agents provide the link between a fixed prosthesis and the supporting prepared tooth structure. 1 Decementation was found to be the second leading cause of failure of the traditional crown and fixed partial dentures, preceded by secondary dental caries. 2,3 Dental luting cements should provide a durable bond between dissimilar materials. 4 They must maintain their integrity while transferring stresses, from crowns and fixed partial dentures to the tooth structure. Act as a barrier against microbial leakage, sealing the interface between the tooth and the restoration and holding them together through some form of surface attachment. 5 This attachment may be mechanical, chemical or a combination of both methods. Polycarboxylate and glass ionomer cements have become immensely popular because of their good wettability and bonding to enamel and dentin. 6 Strength is an important mechanical property to be considered for selecting a luting agent. The luting cements are subjected to compressive and tensile stresses by masticatory forces. 7 Hence, it is necessary for the luting cements to possess good compressive and tensile strength for the success and longevity of the fixed prosthesis. Most of the data available on the strength of the luting cements are derived from studies performed with the cements that were not prepared for use as luting agents, but as bases, liners or restorative materials. Hence, more studies that evaluate the cements that are manufactured specifically to be used as luting agents are required. Mouth temperature and temperature of ingested foods may induce thermal changes within cements in the oral cavity. Laboratory testing for compressive and tensile strengths is generally conducted at room temperature. As the properties of luting cements may be affected by changes in temperature, the measurement of cement strength at increased temperatures may be more clinically significant. 8 Materials and Methods Materials used in the study Poly F polycarboxylate luting cement (Dentsply, DeTrey Germany), Liv Carbo polycarboxylate luting cement (GC Corp., Japan), Fuji I capsule glass ionomer luting cement (GC Corp., Japan), Fuji Plus capsule Resin modified glass ionomer luting cement (GC Corp., Japan), [Figure 1]. Armamentarium used in the study Teflon molds, glass plates, clamps, capsule mixing amalgamator (Solilamat, Technojet), Fuji capsule applier (GC Asia, Singapore), incubator, water bath (Biotech and Scientific Industries, Agra), thermo statistically controlled oven, universal testing machine (Hounsfield), [Figure 2]. 13

Figure 1: Materials used in the study. Figure 3: Molds and specimens. Figure 2: Armamentarium used in the study. Cylindrical Teflon molds of the dimensions, 6 mm in height and 4 mm in diameter, were fabricated for making the specimens for compressive strength testing, Cylindrical Teflon molds of the dimensions, 2 mm in height and 4 mm in diameter, were fabricated for making the specimens for diametral tensile strength testing. The Teflon molds were placed on a glass plate the powder/ liquid cements were proportioned and mixed according to manufacturers recommendations and mixed on a mixing pad with a plastic spatula. The freshly mixed cement was filled into the mold, as for the encapsulated cements, the cement capsules were activated, placed in a capsule mixing amalgamator and triturated according to the manufacturers recommendation, and loaded into the capsule applicator. The mixed cement was then extruded through the nozzle of the capsule directly into the mold. Another glass plate was pressed over the open end of the slightly overfilled mold, and the plates were held firmly against the molds with the help of a clamp. The assembly was then placed in an incubator for 1 h in 100% humidity at 37 C. The specimens were removed from the mold [Figure 3] and stored in distilled water in a water bath at 37 C for the next 23 h. A total of 144 samples were prepared. Testing of the specimen The temperature of the specimens tested was regulated in a thermostatically controlled oven [Figure 4] prior to testing them in a Hounsfield universal testing machine. Figure 4: Thermostatically controlled oven. For the testing of the compressive strength, the cylindrical specimens were mounted vertically along their long axis between the horizontal, parallely placed flat surface of the metal plates of the jig attached to the universal testing machine [Figure 5]. The specimens were loaded at cross head speed of 1 mm/min until they fractured. The load at which the specimen fractured appeared on the monitor and was recorded. For the testing of the diametral tensile strength, the disk specimens were mounted diametrically between the metal plates [Figure 6] and they were tested and the reading was recorded in the manner similar. Statistical analysis Descriptive data are expressed as mean ± standard deviation. One way ANOVA was used for multiple group comparisons (between agents and between temperatures) followed by Newman Keul s range test to assess, which group differs significantly from other. A P = 0.05 or less was considered for statistical significance. Results Table 1 shows the comparison of compressive strength at different temperatures for each luting cement (Graph 1). For Poly F, the mean compressive strengths were 74.00 ± 2.54 Mpa at 23 C, 73.74 ± 2.74 Mpa at 37 C and 71.93 ± 3.25 Mpa at 14

50 C. No statistically significant between the values at different temperature was noticed. For Liv Carbo, the mean compressive strengths were 64.16 ± 2.18 Mpa at 23 C, 63.16 ± 1.88 Mpa at 37 C and 61.76 ± 0.83 Mpa at 50 C. There was no statistically significant between the values at different temperature. For Fuji I, the mean compressive strength were 107.33 ± 2.71 Mpa at 23 C, 105.82 ± 3.07 Mpa at 37 C and 104.37 ± 2.24 Mpa at 50 C. No statistically significant was seen between the values at different temperature. For Fuji Plus, the mean compressive strength were 119.04 ± 2.48 Mpa at 23 C, 119.74 ± 2.46 Mpa at 37 C and 119.21 ± 1.92 Mpa at 50 C. There was no statistically significant noticed between the values at different temperatures. Table 2 shows the comparison of diametral tensile strength values at different temperatures for each luting cement (Graph 2). Figure 5: Specimen being tested for compressive strength. For Poly F, the mean diametral tensile strengths values were 7.42 ± 0.73 Mpa at 23 C, 7.23 ± 0.98 Mpa at 37 C and 6.89 ± 0.97 Mpa at 50 C. No statistically significant between the values at different temperature was noticed. Figure 6: Specimen being tested for diametral tensile strength. Table 1: The comparison of compressive strength values at different temperatures for each luting cement. Materials Compressive strength (Mpa) ANOVA Difference 23 C 37 C 50 C results F value between time P value interval Poly F 74.00±2.54 73.76±2.74 71.93±3.25 F=0.96 Liv Carbo 64.16±2.18 63.16±1.88 61.76±0.83 F=2.91 Fuji I 107.33±2.71 105.82±3.07 104.37±2.24 F=1.80 Fuji Plus 119.04±2.48 119.74±2.46 119.21±1.92 F=0.16 One-way ANOVA, values are expressed as mean±sd, Newman-Keul s range test, P<0.05: Significant, P>0.05: Not significant, SD: Standard deviation Graph 1: Comparison of the compressive strength of each luting cement measured at different temperatures. 15

For Liv Carbo, the mean diametral tensile strength were, 6.55 ± 0.57 MPa at 23 C, 6.18 ± 0.59 Mpa at 37 C and 5.63 ± 0.65 Mpa at 50 C. No statistically significant was noticed between the values. For Fuji I, the mean diametral tensile strength values were 6.16 ± 0.31 Mpa at 23 C, 6.38 ± 0.71 Mpa at 37 C and Table 2: The comparison of diametral tensile strength values at different temperatures for each luting cement. Materials Diametral tensile strength (Mpa) 23 C 37 C 50 C ANOVA results F value P value Poly F 7.42±0.73 7.23±0.98 6.89±0.97 F=0.52 Liv Carbo 6.55±0.57 6.18±0.59 5.63±0.65 F=3.53 Fuji I 6.16±0.31 6.38±0.71 5.99±0.25 F=1.03 Fuji Plus 10.23±1.12 9.81±0.73 9.66±0.95 F=0.62 One-way ANOVA, values are expressed as mean±sd, Newman Keul s range test, P<0.05: Significant, P>0.05: Not significant, SD: Standard deviation Difference between time interval 5.99 ± 0.25 Mpa at 50 C. There was no statistically significant between the values. For Fuji Plus, the mean diametral tensile strength values were, 10.23 ± 1.12 Mpa at 23 C, 9.81 ± 0.73 Mpa at 37 C and 9.66 ± 0.95 Mpa at 50 C. The between the values at different temperatures was not statistically significant. Table 3 shows the comparison of compressive strength and diametral tensile strength at different temperatures, between the luting cement. For the compressive strength, Fuji Plus exhibited the highest strength values at all temperatures, followed by Fuji I > Poly F > Liv Carbo (Graph 3). The values at 23 C were as follows: Fuji plus 119.04 ± 2.48 Mpa, Fuji I 107.33 ± 2.71 Mpa, Poly F 74.0 ± 2.54 Mpa and Liv Carbo 64.16 ± 2.18 Mpa. The in the values was found to be statistically highly significant. At 37 C Fuji Plus 119.74 ± 2.46 Mpa; Fuji I 105.82 ± 3.07 Mpa; Poly F 73.76 ± 2.74 Mpa and Liv Carbo 63.16 ± 1.88 Table 3: The comparison of compressive strength and diametral tensile strength values between luting cements at different temperatures. Materials Compressive strength (Mpa) Diametral tensile strength (Mpa) 23 C 37 C 50 C 23 C 37 C 50 C Poly F 74.0±2.54 73.76±2.74 71.93±3.25 7.42±0.73 a 7.23±0.98 a 6.89±0.97 a Liv Carbo 64.16±2.18 63.16±1.88 61.76±0.83 6.55±0.57 ab 6.18±0.59 a 5.63±0.65 a Fuji I 107.33±2.71 105.82±3.07 104.37±2.34 6.16±0.31 b 6.38±0.31 a 5.99±0.35 ab Fuji Plus 119.04±2.48 119.74±2.46 119.21±1.92 10.23±1.12 9.81±0.73 9.66±0.95 ANOVA F 688.9 638.4 872.9 36.9 28.7 34.2 P <0.001, HS <0.001, HS <0.001, HS <0.01 <0.01 <0.01 Difference between materials One way ANOVA, Newman Keul s range test, a,b :??? Significant between materials aa bb Not significant aaa Not significant aa bb Not significant Graph 2: Comparison of the diametral tensile strength of each luting cement measured at different temperatures. 16

Mpa. The in the values was found to be statistically highly significant. At 50 C Fuji Plus 119.21 ± 1.92 Mpa; Fuji I 104.37 ± 2.34 Mpa; Poly F 71.93 ± 3.25 Mpa and Liv Carbo 61.76 ± 0.23 Mpa. The in the values were found to be statistically highly significant. For the diametral tensile strength, Fuji Plus showed the highest strength values followed by, Poly F > Fuji I = Liv Carbo at all the temperatures (Graph 4). The values at 23 C were Fuji Plus 10.23 ± 1.12 Mpa; Poly F 7.42 ± 0.73 Mpa; Liv Carbo 6.55 ± 0.57 Mpa and Fuji I 6.16 ± 0.31 Mpa. There was statistically significant between values of Fuji Plus and all the other cements whereas the between Poly F and Liv Carbo; Liv Carbo and Fuji I were not statistically significant. At 37 C the values were Fuji Plus 9.81 ± 0.73 Mpa; Poly F 7.23 ± 0.98 Mpa Fuji I 6.38 ± 0.31 Mpa and Liv Carbo 6.18 ± 0.59 Mpa. The between values of Fuji plus and all the other cements was statistically significant. There was no statistically significant between the values of Poly F, Liv Carbo and Fuji I. At 50 C the values were Fuji Plus 9.66 ± 0.95 Mpa; Poly F 6.89 ± 0.97 Mpa; Fuji I 5.99 ± 0.35 Mpa and Liv Carbo 5.63 ± 0.65 Mpa. Fuji Plus differed significantly compared with the other cements. The in the values of Poly F and Fuji I; Liv Carbo and Fuji I were not statistically significant. Graph 3: Comparison of compressive strength between the luting cements at different temperatures. Tensile Strength(MPa) 12.0 10.0 8.0 6.0 4.0 7.42 6.55 6.16 10.24 7.23 6.18 6.38 9.81 6.90 5.63 5.99 9.66 Poly F Liv Carbo Fuji I Fuji Plus 2.0 0.0 23' c 37' c 50' c Temperature Graph 4: Comparison of diametral tensile strength between the luting cements at different temperatures. 17

Discussion The luting cements are one of the most important materials in clinical dentistry because of their application. For acceptable performance in luting application, the cement must have adequate resistance to dissolution in the oral environment. It must also develop an adequately strong bond through mechanical interlocking and adhesion. High strength in compression, shear and tension is required. 6 The demonstration of marginal leakage involving penetration of bacteria to the dentin interface and a reduction in retention of restorations, led to the realization that luting cements possessing good wetting and bonding to enamel and dentin and low toxicity were needed. 6 These concepts led to the development of adhesive cements based on polyacrylic acid. The luting cements are subjected to compressive and tensile stresses during mastication, which mandates the evaluation of these materials for compressive and tensile strength. The plastic deformation differs with varying temperatures and also with the loading rate. The lower loading rate leads to greater plastic deformation. 9 In the present study, a loading rate of 1 mm/min has been used according to specifications. The earlier studies have found to have used a loading rate of 0.1 mm/min and 0.5 mm/min. 8,10 However, irrespective of the loading rate in all the studies, a reduction in compressive strength at raised temperature up to 50 C has been noticed. The plastic deformation at fracture is limited for glass ionomer cements at higher temperature i.e., below 0.5%. The increase in temperature may not affect the strength of the glass ionomer cements. 9 The same reason may also hold good for the newer resin modified glass ionomer cements. At the tested temperatures, Fuji Plus was found to be the strongest in compression followed by Fuji I > Poly F > Liv Carbo. A trend towards the reduction of the diametral tensile strength with the increase in temperature was observed for both the cements, but the s in the values were not statistically significant. In the study conducted by Mesu, 8 the diametral tensile strength values for the polycarboxylate cements at 23 C, 37 C and 50 C were 7.99 Mpa, 6.78 Mpa and 5.94 Mpa respectively. The reduction in the values at raised temperatures was of a lesser degree compared to the reduction in the compressive strength values observed at the same temperatures. In the present study, the average diametral tensile strength values for both the polycarboxylate cements were 6.98 Mpa at 23 C, 6.70 Mpa and 6.26 Mpa at 37 C and 50 C respectively. The reduction in diametral tensile strength values at raised temperatures was less than that of the values found in the earlier study. The mean diametral tensile strength values of the glass ionomer cements Fuji I were 6.16 Mpa at 23 C 6.38 Mpa at 37 C and 5.99 Mpa at 50 C. For the Fuji Plus the mean diametral strength values of 10.23 Mpa, 9.81 Mpa and 9.61 Mpa were recorded at 23 C, 37 C and 50 C, respectively. Fuji I demonstrated a marginal increase in the strength at 37 C and at 50 C a decrease in strength values was noted, compared with the values at 23 C. An insignificant decrease in the diametral tensile strength was noticed at raised temperatures for both the cements. For the polycarboxylate cements, the in the load rates used may have been the cause for the in the results noted in the earlier study and the present study. 9,10 The values of the glass ionomer cements might not have been affected, as the plastic deformation at fracture is less for glass ionomer cements with an increase in temperature. 9 The diametral tensile strength values for all the cements were lower than that of their compressive strengths. The likely explanation being, although the cohesion within the material is identical in both compressive and diametral tensile strength tests, the direction of the forces, however, is reversed. 11 The comparative evaluation of the luting cements for diametral tensile strength showed that, Fuji Plus had the highest strength values followed by Poly F = Fuji I = Liv Carbo at all temperatures. There was a significant (P > 0.01) found in the strength of Fuji Plus and the other cements, whereas there was no much in the values of Poly F, Fuji I and Liv Carbo. The resin modified glass ionomer cement was stronger than the conventional glass ionomer cement when subjected to diametral tensile strength testing. This is in accordance with previous reports. 4,5,12 15 The glass ionomer cements usually display higher diametral tensile strength values than the polycarboxylate cements. 4,5,12,15 In the present study, the glass ionomer cement evaluated had values similar to that of polycarboxylate cements. The exact composition of the encapsulated glass ionomer cement was not known. However, minor variations in P:L ratios and additional component might have influenced the varied strength properties. The mean compressive and diametral tensile strength of the polycarboxylate cements (Poly F and Liv Carbo) were in the range of values reported in earlier studies. 1,4 8,15 17 The mean values of glass ionomer and resin modified glass ionomer luting cements (Fuji I and Fuji Plus) for compressive and diametral tensile strength fall within the range of values documented in previous reports. 1,4 7,12,15,18 22 18

Throughout the study, Fuji Plus showed higher strength properties than the other cements tested. Based on the results of this study, it can be inferred that, an increase in the temperature caused no significant reduction in the compressive and diametral tensile strength of the luting cements evaluated. In the clinical situations, the luting cements might exhibit strength properties, different than that they demonstrate in laboratory investigations. More in vivo studies that investigate the strength properties of the luting cements, when subjected to thermal variations are required. Conclusion 1. Increase in the temperature caused a marginal reduction in the compressive strength of the polycarboxylate and the glass ionomer cements. However, the in the values at 23 C and at higher temperatures was not statistically significant 2. A marginal reduction was seen in the diametral tensile strength of polycarboxylate and glass ionomer cements, with an increase in the temperature. However, the in the values at 23 C and at higher temperatures was not statistically significant 3. At the tested temperatures, the resin modified glass ionomer cement showed higher compressive strength and diametral tensile strength than the other cements. The compressive strength of conventional glass ionomer was higher than that of polycarboxylate cements. The diametral tensile strength of conventional glass ionomer cement and polycarboxylate cements was similar. References 1. Rosenstiel SF, Land MF, Crispin BJ. Dental luting agents: A review of the current literature. J Prosthet Dent 1998;80 (3):280 301. 2. Diaz Arnold AM, Vargas MA, Haselton DR. Current status of luting agents for fixed prosthodontics. J Prosthet Dent 1999;81 (2):135 41. 3. Walton JN, Gardner FM, Agar JR. A survey of crown and fixed partial denture failures: length of service and reasons for replacement. J Prosthet Dent 1986;56 (4):416 21. 4. White SN, Yu Z. Compressive and diametral tensile strengths of current adhesive luting agents. J Prosthet Dent 1993;69 (6):568 72. 5. Li ZC, White SN. Mechanical properties of dental luting cements. J Prosthet Dent 1999;81 (5):597 609. 6. O Brien WJ. Dental Materials: Properties and Selection, 2 nd ed. Chicago: Quintessence; 1997. 7. Anusavice KJ. Philips Science of Dental Materials, 10 th ed. Philadelphia: W.B. Saunders Company; 1999. 8. Mesu FP. The effect of temperature on the compressive and tensile strengths of cements. J Prosthet Dent 1983;49 (1):59 62. 9. Oilo G. Luting cements: a review and comparison. Int Dent J 1991;41 (2):81 8. 10. Oilo G, Espevik S. Stress/strain behavior of some dental luting cements. Acta Odontol Scand 1978;36 (1):45 9. 11. Yap AU, Pek YS, Cheang P. Physico mechanical properties of a fast set highly viscous GIC restorative. J Oral Rehabil 2003;30 (1):1 8. 12. Mitra SB, Kedrowski BL. Long term mechanical properties of glass ionomers. Dent Mater 1994;10 (2):78 82. 13. Li J, von Beetzen M, Sundström F. Strength and setting behavior of resin modified glass ionomer cements. Acta Odontol Scand 1995;53 (5):311 7. 14. Uno S, Finger WJ, Fritz U. Long term mechanical characteristics of resin modified glass ionomer restorative materials. Dent Mater 1996;12 (1):64 9. 15. Craig RG, Powers JM. Restorative Dental Materials, 11 th ed. St. Louis: Mosby; 2002. 16. Powers JM, Johnson ZG, Craig RG. Physical and mechanical properties of zinc polyacrylate dental cements. J Am Dent Assoc 1974;88 (2):380 3. 17. Galun EA, Saleh N, Lewinstein I. Diametral tensile strength and bonding to dentin of type I glass ionomer cements. J Prosthet Dent 1994;72 (4):424 9. 18. Johnson GH, Herbert AH, Powers JM. Changes in properties of glass ionomer luting cements with time. Oper Dent 1988;13 (4):191 6. 19. Cattani Lorente MA, Godin C, Meyer JM. Early strength of glass ionomer cements. Dent Mater 1993;9 (1):57 62. 20. Cattani Lorente MA, Godin C, Meyer JM. Mechanical behavior of glass ionomer cements affected by long term storage in water. Dent Mater 1994;10 (1):37 44. 21. Cattani Lorente MA, Dupuis V, Moya F, Payan J, Meyer JM. Comparative study of the physical properties of a polyacid modified composite resin and a resin modified glass ionomer cement. Dent Mater 1999;15 (1):21 32. 22. Piwowarczyk A, Lauer HC. Mechanical properties of luting cements after water storage. Oper Dent 2003;28 (5):535 42. 19