The success of early identification

Similar documents
Validation Studies. How well does this work??? Speech perception (e.g., Erber & Witt 1977) Early Development... History of the DSL Method

Comparing Speech Perception Abilities of Children with Cochlear Implants and Digital Hearing Aids

Directional microphones have

C HAPTER SEVEN. The Use of FM Technology for Infants and Young Children. Sandra Abbott Gabbard. Introduction

Sonic Spotlight. SmartCompress. Advancing compression technology into the future

WIDEXPRESS THE WIDEX FITTING RATIONALE FOR EVOKE MARCH 2018 ISSUE NO. 38

2/16/2012. Fitting Current Amplification Technology on Infants and Children. Preselection Issues & Procedures

Best Practice Protocols

Using digital hearing aids to visualize real-life effects of signal processing

Evaluation of a digital power hearing aid: SENSO P38 1

Lindsay De Souza M.Cl.Sc AUD Candidate University of Western Ontario: School of Communication Sciences and Disorders

The Situational Hearing Aid Response Profile (SHARP), version 7 BOYS TOWN NATIONAL RESEARCH HOSPITAL. 555 N. 30th St. Omaha, Nebraska 68131

SPEECH PERCEPTION IN A 3-D WORLD

EXECUTIVE SUMMARY Academic in Confidence data removed

Predicting Directional Hearing Aid Benefit for Individual Listeners

Localization 103: Training BiCROS/CROS Wearers for Left-Right Localization

Audiogram+: The ReSound Proprietary Fitting Algorithm

Why? Speech in Noise + Hearing Aids = Problems in Noise. Recall: Two things we must do for hearing loss: Directional Mics & Digital Noise Reduction

Marlene Bagatto & Anne Marie Tharpe. A Sound Foundation Through Early Amplification Conference Chicago, USA December 10, 2013

Critical Review: What are the objective and subjective outcomes of fitting a conventional hearing aid to children with unilateral hearing impairment?

Satisfaction Survey. Oticon Intiga gets it right with first-time users

WIDEXPRESS. no.30. Background

Audiogram+: GN Resound proprietary fitting rule

Oticon Agil success 2011 An International Survey

Best practices in A few favorite resources: Clear areas of agreement: How about these features? The bottom line:

Evidence base for hearing aid features:

Providing Effective Communication Access

The Binaural Advantage: Evidence From Subjective Benefit & Customer Satisfaction Data

New Technology for Effortless Hearing: A Unique Perspective

Bridget Poole, B.S. Lauri Nelson, Ph.D. Karen Munoz, Ed.D.

Differences in Sensation Level between the Widex SoundTracker and Two Real-Ear Analyzers DOI: /jaaa

Efficacy of an Adaptive Directional Microphone and a Noise Reduction System for School-Aged Children

Turn up the volume on life. The powerful choice for your super power users

Effects of Multi-Channel Compression on Speech Intelligibility at the Patients with Loudness-Recruitment

Group Delay or Processing Delay

Initial-Fit Algorithm vs. Probe- Microphone Verification: Comparing Self-Perceived Benefit

Andres, A. M.Cl.Sc (AUD.) Candidate The University of Western Ontario: School of Communication Sciences and Disorders

What Is the Difference between db HL and db SPL?

A comparison of manufacturer-specific prescriptive procedures for infants

Marlene Bagatto The University of Western Ontario, London, Canada. European Pediatric Amplification Conference Istanbul, Turkey November 15, 2011

Verification of soft speech amplification in hearing aid fitting: A comparison of methods

Compression in Hearing Aids

ReSound NoiseTracker II

FREQUENCY LOWERING IN THE PEDIATRIC POPULATION: OUTCOMES AND CONSIDERATIONS FOR FITTING. Capstone. Lauren Virginia Ross, B.A.

Issues faced by people with a Sensorineural Hearing Loss

Effects of Setting Thresholds for the MED- EL Cochlear Implant System in Children

Hearing Aids and Assistive Listening Devices

Beltone Electronics 2601 Patriot Boulevard Glenview, IL U.S.A. (800)

The effect of nonlinear frequency compression and linear frequency transposition on speech perception in school-aged children

Your Hearing Assessment Report

The Devil is in the Fitting Details. What they share in common 8/23/2012 NAL NL2

Slow compression for people with severe to profound hearing loss

DSL v5 in Connexx 7 Mikael Menard, Ph.D., Philippe Lantin Sivantos, 2015.

Paediatric Amplification

EEL 6586, Project - Hearing Aids algorithms

Acoustic feedback occurs in all hearing

Sonic Spotlight. Binaural Coordination: Making the Connection

Improving Audibility with Nonlinear Amplification for Listeners with High-Frequency Loss

Prescribe hearing aids to:

Glossary For Parents. Atresia: closure of the ear canal or absence of an ear opening.

Elements of Effective Hearing Aid Performance (2004) Edgar Villchur Feb 2004 HearingOnline

Testing Digital Hearing Aids

Chapter 7 CONCLUSION AND RECOMMENDATIONS

Baker, A., M.Cl.Sc (AUD) Candidate University of Western Ontario: School of Communication Sciences and Disorders

Frequency refers to how often something happens. Period refers to the time it takes something to happen.

Much of the literature on hearing

Chinnaraj Geetha, Puttabasappa Manjula Department of Audiology, All India Institute of Speech and Hearing, Mysore, India.

Clinical fitting guide

personalization meets innov ation

Optimising Outcomes for Speech Mapping

MedRx HLS Plus. An Instructional Guide to operating the Hearing Loss Simulator and Master Hearing Aid. Hearing Loss Simulator

Four-Channel WDRC Compression with Dynamic Contrast Detection

UvA-DARE (Digital Academic Repository) Perceptual evaluation of noise reduction in hearing aids Brons, I. Link to publication

REFERRAL AND DIAGNOSTIC EVALUATION OF HEARING ACUITY. Better Hearing Philippines Inc.

C HAPTER FOUR. Audiometric Configurations in Children. Andrea L. Pittman. Introduction. Methods

Research Article The Acoustic and Peceptual Effects of Series and Parallel Processing

FREQUENCY COMPOSITION : A NEW APPROACH TO FREQUENCY- LOWERING

Cochlear implants and radio aids. University of Southampton Auditory Implant Service (USAIS)

EHDI in Michigan. Introduction. EHDI Goals and Communication Options. Review of EHDI Goals. Effects of Universal Newborn Hearing Screening (UNHS)

The Two I s in EHDI: Intervention and Impact. Teresa H. Caraway, Ph.D., CCC-SLP, LSLS Cert. AVT Hearts for Hearing Oklahoma City, OK

ASR. ISSN / Audiol Speech Res 2017;13(3): / RESEARCH PAPER

Juan Carlos Tejero-Calado 1, Janet C. Rutledge 2, and Peggy B. Nelson 3

The Use of a High Frequency Emphasis Microphone for Musicians Published on Monday, 09 February :50

Rationale for Binaural Hearing Aid Fittings

Make the world louder!

Audiology Services. Table of Contents. Audiology Services Guidelines : Hearing services

SoundRecover2 More audibility of high-frequency sounds for adults with severe to profound hearing loss

Power Instruments, Power sources: Trends and Drivers. Steve Armstrong September 2015

The Two I s in EHDI: Intervention and Impact. Teresa H. Caraway, Ph.D., CCC-SLP, LSLS Cert. AVT Hearts for Hearing Oklahoma City, OK

Comparison of Performance with a Conventional and a Two-Channel Hearing Aid

Candidacy and Verification of Oticon Speech Rescue TM technology

Online Courses for Parents and Professionals Who Want to Know More About Children who are Deaf or Hard of Hearing

Focus. Children with hearing impairment also benefit from digital hearing instrument technology. Introduction

Walkthrough

HAT Process: Determining HAT for a Student

Digital hearing aids are still

Can you hear me now? Amanda Wolfe, Au.D. Examining speech intelligibility differences between bilateral and unilateral telephone listening conditions

TOPICS IN AMPLIFICATION

Verifying the Lyric Audibility Advantage

Digital. hearing instruments have burst on the

Transcription:

tech topic Fitting Digital Non-Linear Power Aids on Children with Severe-to-Profound Losses The success of early identification of hearing loss in infants, combined with appropriate early amplification intervention, has resulted in better speech and language skills for infants compared to their late identified peers. 1,2 Such enthusiastic commitment to early identification has also prompted hearing care professionals to consider strategies that would ensure an accurate and timely diagnosis of hearing loss, selection of optimal amplification technology, and employment of accurate and efficient verification strategies. 3 Assessing amplification on school-age children will help audiologists understand the unique needs of the pediatric population and will assist them in their role of selecting appropriate amplification for children of all ages. In recent articles, Kuk and colleagues described some of the key features in hearing aids for pediatric applications 4 and those for people with a severe-toprofound degree of hearing loss. 5 The need to use binaural nonlinear wide dynamic range compression (WDRC) hearing aids with a long time constant was proposed based on the observation that the input levels in a child s listening environments change constantly. 6 Wide dynamic range compression hearing aids provide more gain at low inputs and less gain at high inputs and are better suited than linear amplification to ensure audibility of soft speech and comfort for loud sounds. Despite the theoretical advantages of This article was submitted to HR by Sandra Abbott Gabbard, PhD, director of Audiology at the University of Colorado Health Sciences Center; Gwen O Grady, MSPA, clinical instructor at the University of Kansas Medical Center (now at Duke University Medical Center); and Francis Kuk, PhD, director of Audiology at the Widex Hearing Research Laboratory, Lisle, Ill. Correspondence can be addressed to HR or Sandra Abbott Gabbard, PhD, University of Colorado Health Sciences Center, PO Box 6510, Mail Stop F736, Aurora, CO 80045; email: sandra.gabbard@uch.edu. WDRC, the use of nonlinear hearing aids in children is still scarce. Indeed, a recent survey by Tharpe et al. 7 showed that less than 50% of audiologists who worked primarily with children used nonlinear hearing aids for their pediatric clients with severe-to-profound degrees of hearing loss, and only about 15% of audiologists indicated that they recommended digital devices for children. An analog linear hearing aid with either compression limiting or peak clipping was the primary circuit option recommended by respondents of the survey. There may be economic as well as audiologic reasons for the infrequent use of digital or nonlinear hearing aids in children. Low reimbursement rates by states and other agencies may deter audiologists from making such recommendations. This may be a result of the scarcity of definitive evidence presented to such agencies to support the hypothetical advantage of nonlinear hearing aids. On the other hand, a decrease in the perception of loudness in nonlinear hearing aids (compared to linear aids) may be a reason for children with a severe-to-profound hearing loss and their audiologists to continue favoring the use of linear peak-clipping or compressionlimiting hearing aids. On a hypothetical basis, if adequate gain is ensured at low and medium input levels, the reduction of output from hearing aids at a high input level should not be disconcerting to the wearers. Generally speaking, linear circuits provide more output when presented with high inputs compared to a compression circuit. If adequate gain for low and medium inputs is ensured, audibility for the important speech signals will be preserved. As Ching et al. 8 demonstrated, an increase in output at a high input level does not improve intelligibility; it primarily increases the perception of loudness. Hearing aid wearers may learn to accept this reduction in output from the nonlinear hearing aids if they are given the chance to acclimatize to the hearing aid processing. Kuk 9 demonstrated that satisfaction and performance with hearing aids improved over time in adult hearing aid wearers. Reasons for the infrequent recommendation of WDRC hearing aids for children with a severe-to-profound hearing loss might also include a limitation in the availability of hearing aids with such output capability. Digital signal processing in hearing aids now allows for WDRC capabilities in high-gain, high-output power hearing aids with low compression thresholds. These devices have the advantage of providing extra audibility for soft sounds while preserving (or enhancing) intelligibility and comfort at higher input levels. 10 The current study was undertaken to compare the objective and subjective performance of digital power compression hearing aids over analog (and programmable) power hearing aids in school-age children who have a severe-to-profound degree of hearing loss. Method Subjects: Thirteen children with a symmetrical (within 10 db) severe-to-profound hearing loss participated in the study. Eight of the children were recruited from the University of Colorado Health Sciences Center (UC) and 5 were recruited from the University of Kansas Medical Center (KUMC). Of the 8 children from the University of Colorado, 6 had a puretone average (PTA) between 70-80 db HL and 2 had a PTA around 95 db HL. Of the 5 subjects from the University of Kansas, 2 had a PTA of 90 db HL, 2 had a PTA of 100 db HL, and one had a PTA of 110 db HL. With the exception of one child who was 6 years old, the other children ranged from 9-14 years of age with a mean age of 12.2 years (SD = 2.6 years). All the children used oral communication as their primary mode of communication and were mainstreamed into regular classrooms. Most of the children wore binaural analog linear power hearing aids since they were 2-3 years of age. Informed consent was obtained from all the children (and their parents), and they were compensated for their participation. The clinicians did not make any claims of superior performance for the digital hearing aids to the study subjects, their parents, or teachers. Study hearing aids: The hearing aid

Fitting Digital Power Aids on Children 1a 1b FIGURES 1a-1b. Mean binaural sound-field thresholds for subjects at the UC site (1a) and subjects at the KUMC site (1b). "U" represents unaided thresholds; "O" represents aided thresholds with subjects own hearing aids; "S" represents aided thresholds with the study hearing aids. Asterisks represent significant aided threshold difference between hearing aids. used in this study was the Widex Senso P38 (binaurally fitted). This is a digital 3- channel hearing aid that utilizes adaptive, slow-acting Enhanced Dynamic Range Compression (EDRC) as the processing algorithm. A low compression threshold at 20 db HL is used in each of its three channels. High-level compression (HLC) is used above a conversational input level in each channel to further minimize the risk from a high output (ie, over-amplification, saturation). Ringdahl et al. 11 provided a detailed description of the characteristics of this hearing aid. Procedure: All audiometric testing was performed at the speech and hearing clinic of the respective sites. Typically, each student was seen for a minimum of 4-5 sessions. Subject candidacy for inclusion into the study was determined during the first visit. The adequacy of the child s own hearing aids and earmolds was also evaluated. Adjustment of the personal hearing aids was made and new earmolds around 10-35 db HL across frequencies. The differences were statistically significant at the 0.05 level at all frequencies. Figure 1b shows a 15-20 db improvement in aided thresholds below 500 Hz for KUMC subjects. The magnitude of the improvement decreased toward the higher frequencies such that the aided thresholds at 1000 Hz and 2000 Hz were only about 5-10 db better than those obtained with their own hearing aids. The aided thresholds with the study hearing aids at 3000 Hz and 4000 Hz were around 60 db HL and were poorer than those with the subjects own hearing aids. Individual two-tailed t-tests revealed a statistically significant difference at 250 Hz and 500 Hz, but non-significant difference at higher frequencies. One reason for the high aided thresholds may be the higher unaided thresholds of the KUMC children (many had thresholds beyond the limits of the audiometer). A possible reason for the poorer aided thresholds obtained with the study hearing aids than with the chilwere ordered when necessary. Speech recognition ability with the child s own hearing aids (and earmolds) was evaluated during the second visit. In addition, the aided thresholds with the child s own hearing aids were also determined. For some children whose hearing aids and earmolds were judged to be appropriate, this measure was determined during the first session instead. All testing was done in a sound booth using commercial audiometers. The W-22 word lists were presented in live-voice at 35 db HL in quiet and at 50 db HL in a speech-shaped noise (SNR=+10) background. Auditory-alone and auditoryplus-visual modes were used. Mode of presentation was counterbalanced across subjects. Fitting of the study hearing aids followed completion of the speech test under strict guidelines. Aided thresholds with the study hearing aids were then determined. Children either completed speech testing with the study hearing aids on the same day or returned the next day to complete speech testing. The Student Inventory of the LIFE questionnaire 12 was also completed during this session. The children returned at 1 month and at 3 months post-fitting to complete another round of speech recognition testing with the W-22 words. At the 3-month visit, the children also returned the LIFE questionnaire, the Widex Hearing Aid Questionnaire for Children, and the Widex Pediatric Questionnaire for Parents. Results Aided Soundfield Thresholds: The mean binaural aided soundfield thresholds for each group of subjects are separately reported in Figures 1a-1b. Soundfield aided thresholds for subjects own hearing aids (O) and for the study hearing aids (S) are included for comparison. For the UC subjects (n=8, Fig. 1a), the aided thresholds obtained with the study hearing aids were about 10-15 db better than those with the children s own hearing aids. This improved the aided thresholds from around 30-50 db HL to 2a 2b FIGURES 2a-2b. Average speech recognition scores on the W-22 word lists measured with the subjects own hearing aids and with the study hearing aids at different times (initial, 1-month, and 3-months post fitting) and across listening conditions (A- auditory only; AV-auditory plus visual) at the UC site (2a) and the KUMC site (2b).

FIGURES 3a-3b. Mean ease of listening rating for each item on the LIFE questionnaire: Student Form at the UC site (3a) and the KUMC site (3b). The maximum rating for each of the first 10 items was "10" and the maximum rating for each of the next 5 items was "20." Items that showed significant difference between hearing aids were marked with an asterisk (*). ing aids was noted in the 50 db HL test condition. Figure 2b shows that the effect of the study hearing aids was also evident in the KUMC subjects. At the initial visit for the 35 db HL condition, an 8% improvement (2% versus 10%) was seen in the auditory-alone condition, and this improvement continued to 18% (2% versus 20%) at the 3-months interval. The same was true for the auditory-plus-visual condition where a 17% (29% versus 46%) improvement was seen initially with the study hearing aids, and improvement continued to 24% (29% versus 53%) at the 3-month visit. At the 50 db HL auditory-alone condition, no improvement in speech score was seen until the 1- month and 3-months visits in both the auditory and auditory plus visual conditions. Student s LIFE Questionnaire: The mean ratings for items on the LIFE Questionnaire: Student Form are summarized in Figures 3a-3b for UC and KUMC children respectively. At the UC site (Figure 3a), the average child rated the study hearing aids higher than his/her own hearing aids on all test items, suggesting less difficulty across all classroom and school situations with the study hearing aids than with their own hearing aids. Items that were statistically different at the 0.05 level were identified with an asterisk. These items included: teacher moving, small/large group, school assembly, and lunchroom. Similar improvement was also seen with the KUMC children (Figure 3b) across the same listening situations. The majority of items reached statistical significance (p < 0.05) and was identified with an asterisk. Some items showing the most change included #3 (teacher back), #4 (hallway noise), #11 (small group learning), #12 (gymnasium), #14 (lunch- dren s own hearing aids may be related to the absence of (or minimal) saturation distortion in the study hearing aids. The children may have responded to saturation distortion products when they were tested with their own hearing aids. Speech Recognition Scores: Figures 2a-2b summarize the average speech recognition scores at the UC site and the KUMC site respectively. For the UC children (Figure 2a) at the 35 db HL auditoryalone condition, the average subject scored 11% improvement with the study hearing aids compared to their own aids at the initial visit. An additional 5% improvement was seen at the 1-month follow-up. The scores at the 1-month and 3-month visits were significantly different from the subjects own hearing aids (p < 0.05). A similar trend, but with a greater magnitude of improvement, was observed in the 35 db HL auditory-plus-visual condition. A small (6%) non-significant improvement of the study hearing aids over subjects own hearroom), and #15 (hanging coats). These items typically represented mild-to-moderately noisy environments and required listening without many visual cues. Parent s LIFE Questionnaire: Because the responses from the parents to their children s hearing aids were similar between the two sites, their responses were collapsed for presentation. Figure 4 shows the percentage of parents who reported that their children performed a specific auditory behavior more frequently with the study hearing aids than with their own hearing aids. At least 60% of parents reported to the first five listening behaviors (to speech and sounds). As many as 33% of parents reported that their children were more socially active while wearing the study hearing aids and 23% reported that their children were less bothered by loud sounds. Over 80% of the parents were satisfied with the study hearing aids. Figure 5 summarizes the percentage of parents who reported that their children could understand better with the study FIGURE 4. Percentage of parents who reported (on the Widex Parent Questionnaire) that their children exhibited the indicated listening behaviors more frequently with the study hearing aids than their own hearing aids. FIGURE 5. Percentage of parents who reported (on the Widex Parent Questionnaire) that their children performed better with the study hearing aids than their own hearing aids in listening situations inside and outside of the home.

FIGURE 6. Percentage of children who reported that they performed better with the study hearing aids than their own hearing aids on a list of listening situations on the Widex Hearing Aid Questionnaire for Children. FIGURE 7. Number of children who preferred their own hearing aids, the study hearing aids, or who indicated the same preference at different evaluation times. hearing aids than with their own hearing aids in specific listening environments in the home and outside the home. About 60%-80%+ of parents reported that their children understand speech better with the study hearing aids across listening environments. The most significant situations were the telephone (85% better) and the grocery store (85% better). Of the 12 parents who reported, 4 noticed a change in their children s speech production ability since wearing the study hearing aids. All these parents reported a change in voice quality and an increase in their accuracy of articulation. Two reported a decrease in voice loudness and 2 an increase in voice loudness. Two reported an increase in self-correction and 3 reported more accurate imitation of speech sounds (ie, easier simulation). Three parents also reported an increase in the complexity of their children s sentence structure. Children s Questionnaire: Figure 6 shows the percentage of children who rated the study hearing aids as better than their own hearing aids in the list of listening situations. In almost all cases, at least 60% (and as many as 90%) of the children rated the study hearing aids as better than their own hearing aids in allowing them to hear and understand. Upon closer examination, many of these items that were rated higher involved listening from a distance (eg, call from another room, call from behind ) or listening in moderately noisy situations (eg, school bus, playground ). Interestingly, only 61% of the children rated the study hearing aids as better than their own hearing aids on the telephone (whereas 85% of their parents reported so). Figure 7 summarizes the number of children who preferred the study hearing aids over their own hearing aids at different times (initial, 1-month, and 3-months visits). Although 9 of the 13 children preferred the study hearing aids initially, 11 preferred the study hearing aids at the conclusion of the study (the other 2 reported same performance between hearing aids). Reasons for the preference included better hearing at more places (6); hearing sounds not heard before (6); speak better (6); and better grades (6). Other comments included hearing more soft sounds, better on the telephone, less feedback, and less banging sounds (as in discomfort). Discussion The results of the study showed that a 3- channel digital nonlinear power hearing aid yielded higher satisfaction/performance over analog power hearing aids for children with a severe-to-profound degree of hearing loss. Better aided soundfield thresholds, improved speech understanding for low input sounds, enhanced speech-reading skills, and a general improvement in communication in various listening situations, as assessed on the LIFE and the Widex questionnaires, were reported. Some children and their parents/teachers also reported an improvement in speech production ability. On the other hand, the ability to understand speech in noise at a moderate input level was not affected (although slightly improved for some children). It is worthwhile to speculate which hearing aid feature(s) may have contributed to the improved performance. Performance at low input levels: The availability of more gain (and output) at low input levels through the use of a low compression threshold at 20 db HL could have accounted for the improved speech recognition at 35 db HL (auditoryalone and auditory-plus-visual), the subjective reports of hearing more sounds at a distance, and the improved speech production in some children. Kuk 10 has pointed out that, for the same input-output curve above the compression threshold (CT), lowering the CT would yield higher gain for low input sounds below the CT. This allows for greater audibility (and thus intelligibility). Similar observations were also made for adults 13 and children 14 in other studies. Performance at moderately high input levels: The current study did not show an immediate improvement in speech recognition ability at the 50 db HL condition with the study hearing aids, although a slight improvement was seen at later times in some children. Likewise, many children reported a clearer sound perception and better performance in mild-to-moderately noisy environments (as shown in the questionnaires). Such observations may have resulted from the improved specificity of multichannel processing and the extra gain for soft sounds provided by the study hearing aids. One may also expect some improvements to have resulted from the action of the high-level compression (HLC) used in the study hearing aids. Recall that HLC further reduces gain above a conversational input in order to minimize excessive output and preserve the temporal waveform cues. Such cues could be important in decoding supra-segmental information in the speech input. Van Tasell et al. 15

Fitting Digital Power Aids on Children demonstrated an increased reliance on such cues as one s hearing loss increased. The concept of HLC may create a negative impression at the initial fitting for some children who are accustomed to wearing linear hearing aids. Almost half of the children in this study indicated at the initial visit that sounds were too soft, not clear, not loud enough, or that they cannot hear with the study hearing aids. This is not surprising given that all of these children had used linear hearing aids since they were 2-3 years of age. This initial reaction was anticipated; therefore, gain settings on the study hearing aids were not increased if the aided thresholds were appropriate. Consequently, it is possible that some children may have been tested at a loudness level below what they were accustomed to. From that standpoint, it is just as important to note that speech recognition scores at the input level of 50 db HL were not affected negatively. Speech recognition improved over time for some children. In this study, those children who initially complained of insufficient loudness returned in a week with positive comments about the study hearing aids. This confirms the belief that, minimally, HLC does not negatively affect speech intelligibility. Indeed, it may improve speech perception over time for those whose perception may have been compromised by saturation distortion (ie, peak clipping) and/or reduction of temporal contrasts (ie, compression limiting). Speech production ability: Although not universal, an improvement in speech production ability was reported in 4 of the 8 children at the UC site. Interestingly, none of the children at the KUMC site reported an improvement in speech production ability. The poorer unaided and aided thresholds and the older age of the children at the KUMC site may explain their lack of improvement in speech production abilities. The number of channels in a nonlinear hearing aid may affect a child s progress in speech production. During vocalization, speech produced by a speaker at a normal level would measure 15 db-20 db higher at the level of the ear than at a conversational distance of 1 meter. 16 If the child wears a single-channel linear hearing aid (assume no VC adjustment), the high input would result in a high output. This extra output (especially in the lows) could mask the higher frequencies and render them inaudible (ie, upward spread of masking), or it may saturate the hearing aid to result in distortion. In both cases, the higher frequency sounds may not be audible to the child. If the child wears a single-channel compression hearing aid, the high input would result in gain reduction across all frequencies and render the high frequencies inaudible. It would be difficult for children to improve their speech production skills if they cannot hear and/or monitor their own production consistently. In a multiple-channel hearing aid, the high-level low frequency input at the microphone would activate compression in the low frequency channel only and reduce its output. This spares the high frequencies and may preserve audibility in this region, allowing children to hear/monitor their own high frequency speech more consistently. Such consistent input may be the reason for improved speech articulation seen in some of the UC children. Such an observation was also noted in another study of a digital multichannel hearing aid in children with up to a moderately severe hearing loss. 14 Is Digital Necessary? A frequently asked question is whether digital hearing aids are necessary for children. From a practical point of view, it is difficult to design an analog multichannel nonlinear hearing aids with a low compression threshold without problems such as high current drain, increased circuit noise, and increased likelihood of feedback. 10 Digital techniques offer the potential to reduce these problems. Specifically, their use could: 1) Result in more flexible and specific filter designs; 2) Implement an expansion circuit below the CT to minimize the perception of circuit noise, and 3) Employ feedback management techniques that allow the availability of high gain with less likelihood of feedback. Indeed, several of the subjects in this study indicated that one of the reasons for their preference is the reduction of feedback. The minimization of artifacts while allowing the use of available gain is an important advantage of applying DSP techniques in today s hearing aids. Conclusion Results from this study support the use of multiple channel nonlinear EDRC hearing aids with a low CT for children with a severe-to-profound degree of hearing loss. Indeed, it may be even more desirable than the use of linear hearing aids which use compression limiting or peak clipping to limit output.the benefits seen in this study include: Improved aided thresholds by 10-20 db across frequencies; Improved speech recognition at a low input level (35 db HL) in quiet, with and without visual cues; No decrease (or a slight increase over time) in speech recognition in noise at a moderate input level (50 db HL), with and without visual cues; Improved subjective satisfaction with amplification across a range of daily listening situations as reflected on the LIFE and the Widex questionnaires; Improved parental report on hearing aid use; Improved speech production ability in four children. References 1. Yoshinaga-Itano C, Sedey A, Coulter D, Mehl A. Language of early- and later-identified children with hearing loss. Pediatrics. 1998;102(5):1-10. 2. Yoshinaga-Itano C. Successful outcomes for deaf and hard-of-hearing children. Sem Hear. 2000;21(4):309-326. 3. Gabbard SA, Thomson V, Brown AS. Considerations for universal hearing screening, audiologic assessment and intervention. Audiology Today. 1998; [Monograph] December: 8-10. 4. Kuk F, Marcoux A. Factors ensuring consistent audibility in pediatric hearing aid fitting. J Amer Acad Audiol. 2002;13:503-520. 5. Kuk F, Ludvigsen C. Hearing aid design and fitting solutions for persons with severe-to-profound losses. Hear Jour. 2000; 53(8):29-37. 6. Stelmachowicz P, Mace A, Kopun J, Carney E. Long-term and short-term characteristics of speech: implications for hearing aid selection for young children. J Speech Hear Res. 1993;36(3):609-620. 7. Tharpe AM, Fino-Szumski M, Bess F. Survey of hearing aid fitting practices for children with multiple impairments. Amer Jour Audiol. 2001;10(1):32-40. 8. Ching T, Dillon H, Byrne D. Speech recognition of hearing-impaired listeners: Predictions from audibility and the limited role of high frequency amplification. J Acoust Soc Amer. 1998;103:1128-1140.

Fitting Digital Power Aids on Children 9. Kuk F. Adaptation to enhanced dynamic range compression (EDRC) - Examples from the SENSO P38 digital hearing aid. Sem Hear. 2001;22(2):161-172. 10. Kuk F. Optimizing compression: Advantages of low compression threshold. In: KE Strom & S Kochkin (ed) High Performance Hearing Solutions, Vol. 3. Hearing Review.1999; [Suppl] 6(1):44-47. 11. Ringdahl A, Magnusson L, Edberg P, Thelin L. Clinical evaluation of a digital power hearing instrument. Hearing Review. 2000;7(3):59-64. 12. Anderson K, Smaldino J. The Listening Inventories For Education (LIFE). Tampa, FL: Educational Audiology Association, 1998. 13. Valente M, Fabry D, Potts L, Sandlin R. Comparing the performance of the Widex Senso digital hearing aid with analog hearing aids. J Amer Acad Audiol. 1998;9:342-360. 14. Kuk F, Kollofski C, Brown S, Melum A, Rosenthal A. Use of a digital hearing aid with directional microphones in schoolaged children. J Amer Acad Audiol. 1999; 10(10):535-548. 15. Van Tasell D, Soli S, Kirby V, Widin G. Speech waveform envelop cues for consonant recognition. J Acoust Soc Amer. 1987; 82(4):1152-1161. 16. Cornelisse L, Gagne J, Seewald R. Ear level recordings of the long-term average spectrum of speech. Ear Hear. 1991;12(1):47-54. Reprinted with permission. Fitting Digital Non-Linear Power Aids on Children with Severe-to-Profound Losses, Hearing Review, July 2003; Volume 10, Number 7: Pages 44, 46, 47, 48, & 49. DAR59