Subject variability in short-term audiometric

Similar documents
A three-frequency audiogram for use in industry

Hearing Conservation Program. Santa Clara University 500 El Camino Real Santa Clara, CA 95053

INTERNATIONAL MODULE SYLLABUS W503 NOISE MEASUREMENT AND ITS EFFECTS

Minimum Training Guidelines Surveillance Audiometry

Hearing Conservation Services Specifications

HEARING CONSERVATION PROCEDURE

S ound is a form of energy generated by vibration. It can be

Hearing Conservation Program

AS/NZS :2014. Occupational noise management AS/NZS :2014. Part 4: Auditory assessment. Australian/New Zealand Standard

There will be a 40 short answer question open book examination with an allowed time of 120 minutes.

Hearing Conservation in the Primary Aluminium Industry

FACE THE MUSIC: A BEFORE AND AFTER STUDY OF THE HEARING ACUITY OF CLASSICAL MUSIC STUDENTS

Hearing Loss and Conservation in Industrial Settings

THE 75 db(a) THRESHOLD LEVEL OF THE PHYSICAL AGENTS DIRECTIVE: A FLAWED EVOLUTION

Hearing Conservation Program Evaluation Checklist

HEARING CONSERVATION CHECKLIST

Noise Induced Hearing loss Prevention, diagnosis and management

BOHS / OHlearning Course Specification

Current practices in noise health surveillance

Title Audiometric Testing Owner CG Nurse Lead. 1.2 To confirm the efficiency of the hearing conservation programme.

Vision Painting Inc. Safety Management System

Asymmetric sensorineural hearing thresholds in the non-noise-exposed UK population: a retrospective analysis

Air conduction hearing thresholds of young and older Japanese adults for pure tones from 125 Hz to 16 khz

Supplementary Online Content

Optimal Design: Bekesy Test for Mobile

(b) is as low as is reasonably practicable, where it is not reasonably practicable to meet the standard under clause (a).

Health, Safety, Security and Environment

HEARING CONSERVATION PROGRAM REVISED AS OF 12 JULY 2010

Medical Surveillance for Hearing Loss

UCSD HEARING CONSERVATION PROGRAM Environment, Health & Safety (EH&S) and Center for Occupational & Environmental Medicine (COEM) 2017

Procedure Number 310 TVA Safety Procedure Page 1 of 6 Hearing Conservation Revision 0 January 6, 2003

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN ISO :1998

Eliminate the Most Common Challenges in Audiometric Testing A Case for Tablet Audiometry in Occupational Hearing Conservation

SNAP-ON INCORPORATED STANDARD ON HEARING CONSERVATION

What s New? Example 2 Employee B. Example 1 - Employee A

Organisation Internationale de Métrologie Légale

Hearing Conservation Program April 27, 2018

Santa Clarita Community College District HEARING CONSERVATION PROGRAM. Revised

Hearing Conservation Program

Dog noise as a risk factor for hearing loss among police dog handlers

HEARING CONSERVATION PURPOSE

Auditory Threshold Shift and the Factor of Age in Deaf Children. Khayria A Al-Abduljawad, PhD*

INDH 5131 Controls of Occupational Hazards. Noise & Hearing Conservation. Part II. V. Audiometric Testing

Acoustics Estimation of noiseinduced

Chapter 9 Hearing loss

3M Center for Hearing Conservation

12th ICBEN Congress on Noise as a Public Health Problem

Hearing Conservation Program

IEC/TC 29 Electroacoustics. Status: September 2010

Occupational Noise Exposure

CCS Administrative Procedure H Hearing Conservation

A survey of hearing loss in army aircrew

San Diego Community College OSHA Standards

Hearing Conservation Program

Hearing Conservation Program

THE ASSESSMENT OF OCCUPATIONAL NOISE EXPOSURE

HEARING CONSERVATION PROGRAM

HEARING CONSERVATION PROGRAM

SOUTHERN UTAH UNIVERSITY S WRITTEN HEARING CONSERVATION PROGRAM December 2017

Proposed EU physical agents directives on noise and vibration

ISO INTERNATIONAL STANDARD

Model Safety Program

Proceedings of Meetings on Acoustics

Facing the Music: Helping classical musicians comply with the Control of Noise at Work Regulations

C HAPTER FOUR. Audiometric Configurations in Children. Andrea L. Pittman. Introduction. Methods

Health Standards to Protect Miners from Hearing Loss

Effective Date: 27-February Table of Contents

Sandra Gordon-Salant Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742

Recommended Procedure. Industrial Audiometry

Auditory and Subjective Effects of Airborne Noise from Industrial Ultrasonic Sources

The Safety and Health at Work Act 2005

NC Employees Workplace Program Requirements for Safety and Health. Hearing Conservation

Clinical applications of otoacoustic emissions in Industry. Prof. Dr. B. Vinck, MSc, PhD University of Ghent, Belgium

HEARING CONSERVATION REPORT

Impact of Noise on Hearing Amongst Commercial Motor Bike Riders in Benin- City, Nigeria.

NAVAL SUBMARINE MEDICAL CENTER NAVAL SUBMARINE BASE NEW LONDON GROTON, CONNECTICUT MEMORANDUM REPORT 70-2

White Paper: The long-term cost of noise exposure David A. Nelson, INCE Bd. Cert., Principal Consultant, Nelson Acoustics

Hearing Conservation Program

Your Company Hearing Conservation Program

WORKPLACE SAFETY AND INSURANCE APPEALS TRIBUNAL DECISION NO. 1945/04

NOISE-INDUCED HEARING IMPAIRMENT AS AN OCCUPATIONAL RISK FACTOR AMONG NIGERIAN TRADERS. A. D. A. IGHOROJE, C. MARCHIE, and E. D.

TAMPA ELECTRIC COMPANY ENERGY SUPPLY HEARING CONSERVATION PROGRAM

Hearing Conservation Program

THE OUTCOME OF ACUTE OTITIS MEDIA (A REPORT TO THE MEDICAL RESEARCH COUNCIL)

How high-frequency do children hear?

Hearing Conservation Program

UNCONTROLLED IF PRINTED Hearing Conservation

Reference: Mark S. Sanders and Ernest J. McCormick. Human Factors Engineering and Design. McGRAW-HILL, 7 TH Edition. NOISE

L G Davison*, BSc C Barlow, PhD, MIOA M Ashmore, RHAD, MIOA R Weinstein, RHAD Southampton Solent University Faculty of Maritime and Technology

UC Merced Hearing Conservation Program

TOWN OF FAIRFIELD PUBLIC HEALTH NURSING. MANUAL: School Health APPROVED BY: Board of Health School Medical Advisor

THESIS PRESENTATION. The Reference Equivalent Threshold Sound Pressure Level (RETSPL) values of the Creare headphones

Hearing Conservation Program Table of Contents

Recommended Procedure. Industrial Audiometry

A case study of construction noise exposure for preserving worker s hearing in Egypt

Contents. 1) Purpose ) Policy ) Definitions ) Procedure a) Requirements b) Noise standard... 4

Effect of ear-defenders (ear-muffs) on the localization of sound

Early detection of noise induced hearing loss by using ultra high frequency audiometry

SICKNESS ABSENCE BEFORE THE FIRST CLINICAL

Hearing loss amongst classical music students

Transcription:

British Journal of Industrial Medicine, 1973, 30, 271-275 Subject variability in short-term audiometric recording B. P. R. HARTLEY', R. W. HOWELL2, A. SINCLAIR,3 D. A. D. SLATTERY4 British Steel Corporation Hartley, B. P. R., Howell, R. W., Sinclair, A., and Slattery, D. A. D. (1973). British Journal of Industrial Medicine, 30, 271-275. Subject variability in short-term audiometric recording. The reliability of a single audiogram at one examination has not been established under industrial conditions. It has previously been suggested that when audiograms are taken they should be performed at least three times, preferably not at one sitting, and that the mean level at each frequency should be taken as the definitive value of hearing level. This study seeks to compare the reliability of three audiograms taken at a single session, but with a break between tests, with three audiograms taken at roughly weekly intervals. One hundred and thirty-two apprentices (average age 16 years) without occupational noise exposure were examined with a Peters audiometer, using one operator only at each of the two works involved. At a third works 45 men (average age 36 years), mostly with occupational noise exposure, had three audiograms taken within an hour using a self-recording audiometer. Not only did the mean of three audiograms from a single session show no practical differencewhencompared withthe mean of three readings takenon separate occasions roughly a week apart, but the second audiogram of the first three was found to be generally representative of the mean of these three. In only 4 of 132 subjects did the second audiogram vary by more than 3 db from the mean of the first three readings. It is suggested that single audiogram examination should be replaced by two audiograms routinely carried out at a single session, and that in the absence of any large difference (say 5 db) between the two readings the second should be adopted. In this series, variability between operators (at 3 and 4 khz) exceeded mean subject variability. There appeared to be no reduction in subject variability when a self-recording machine was used. Almost all current audiometry in industry in this they should be performed at least three times, country is based on a single audiogram at each preferably not at one sitting, and that the mean at subject's attendance. The reliability of a single each frequency be taken as the definitive value of audiogram has not been established under industrial hearing level. Howell and Hartley (1972) have conditions. Indeed, Burns and Robinson (1970) suggested that the chances of getting a man released strongly advocate that when audiograms are taken on three separate occasions may not be realistic, that repeat audiograms may have to be done at the initial attendance, and that further studies to 'Stocksbridge Works, Stocksbridge, near Sheffield ascertain the 2Head Office, Grosvenor Place, London SWI reliability and necessity of serial audiometry should be carried out in industrial settings. 'Ebbw Vale Works, Ebbw Vale 'Rotherham Works, Rotherham This paper presents the findings of one such study. 27:

272 B. P. R. Hartley, R. W. Howell, A. Sinclair, and D. A. D. Slattery Methods and results In this paper all measured hearing levels in excess of the International Organization for Standardization's (ISO) zero (i.e., elevations of threshold) are shown as positive figures, while hearing levels less than the ISO zero (lowering of threshold) are shown as negative figures. The term 'reliability' is used in the conventional sense of sound and consistent quality. Reliability can vary between absolute and zero. In audiometric recording and interpretation this assessment will often be a subjective evaluation which will vary with the individual reader's judgement and beliefs. For example, the value of the single audiometric examination commonly used in industry may well be regarded as reliable by some users, as doubtful by others, and as unreliable by a third group. 'Variability' as applied to audiometric measurements implies that readings may be neither exactly reproducible nor constant. Factors which affect reproducibility or variability include operator error, machine error, patient error, and biological variation as well as more appreciated factors such as pathological or noise-induced damage, presbycusis and wax in the ears. Apprentices from two works, A (mean age 16-1 years) and B (mean age 16-8 years), were examined. They were free from occupational noise exposure and hence of the difficulties from temporary threshold shift which could arise in such a study. The manual audiometers used were the diagnostic audiometers manufactured by Peters, which offer air and bone conduction measurements and masking facilities. Three pure-tone, air conduction audiograms were carried out on each subject within an hour. A further audiogram was done on two subsequent occasions at roughly weekly intervals. Audiograms were carried out by the one operator at each works; the results of previous audiograms in the series were not available to her until the end of the study. At a third works (C) 45 men of various ages (mean 36 years), mostly with occupational noise exposure, had three audiograms taken within an hour using a Medical Measurement Incorporated (MMI) self-recording audiometer. The MMI audiometer automatically records discrete frequency and air conduction thresholds at six frequencies for each ear. Each ear is tested for 30 seconds at each frequency and, in addition, the audiometer incorporates several other features including the choice of pulsed or continuous tones and manual or automatic validity checks. Recording is subject controlled. Instructions to the men were given by the one operator throughout the series. All audiograms were carried out in audiometry booths in quiet rooms in medical departments, and all machines were calibrated to ISO standards. Results The comparison of mean audiometric readings by time interval is shown in Table 1. The means of the readings at 3 and 4 khz for the two works using a Peters audiometer, and the means of 1 and 2 khz for all three works are given. Means are based on individual hearing levels for both ears, aggregated and divided by 4. For example, a left ear reading of 5 db at 3 khz and 5 db at 4 khz plus a right ear reading of 0 db at 3 khz and 10 db at 4 khz would aggregate to 20 db and give a mean of 5 db for that individual. The mean maximum variations in the individual's readings for three and five audiograms are shown in Table 2. For example, a subject with a mean score at 3 and 4 khz of 5 db at the first reading, 2 5 db at the second reading, and 10 db at the third reading would be credited with a maximum variation of 7.5 db (10-2 5) over three readings. The three readings suggested by Burns and Robinson (1970) as not at one sitting, are shown in this series as audiograms 1, 4, and 5 (Table 3). The means of the three audiograms taken within an hour (1, 2, and 3) are compared on the lines of Table 2 with the means of readings 1, 4, and 5. If the two series are found to be acceptably close in practical terms then the advantages of a single session over TABLE 1 COMPARISON OF MEAN AUDIOMETRIC READINGS BY TIME INTERVAL AND FREQUENCY (khz) AT THREE WORKS Readings Works Audiometer No. of men 1 2 3 4 5 (within I hr) (after I wk) (after 1 wk) Mean reading at I and 2 khz (both A Peters 69 2-8 2-0 2-0 21 2-1 ears) B Peters 63 2-2 1.1 0 5 1-5 1-2 C MMI 45 9-4 8-0 8-2 Difference between the means of A and B 0-6 0 9 1-5 0-6 0 9 Mean reading at 3 and 4 khz (both A Peters 69 2 5 1 5 0-8 1-7 1-6 ears) B Peters 63-0-2-1-7-2-6-1P1-1-8 Difference between the means of A and B 2-7 3-2 3-4 2-8 3-4

Subject variability in short-terni audiometric recording 273 TABLE 2 MEAN OF INDIVIDUAL SUBJECTS' MAXIMUM VARIATION BETWEEN AUDIOGRAMS Works Audiometer 1-2 khz 3-4 khz (both ears) (both ears) 3 readings within 1 hr............ A Peters 2-0 db 2-9 db B Peters 3-5 db 41 db C MMI 4 5 db 5 readings over 3 weeks (approx.)........ A Peters 3-4 db 4 5 db B Peters 5-2 db 5-8 db TABLE 3 groupings shown in Table 3 very similar, especially COMPARISON OF MEANS OF AUDIOGRAMS I + 2 + 3, when considered in the context of total audiometric 1 + 4 + 5, and 2 only reliability, but the meanmaximum variations between the 1, 2, 3 and the 1, 4, 5 sets are also very similar, Audiograms (db) with slightly smaller average variation in the 1, 2, 3 Works Audiograms (db) group at both works at both 1-2 khz and 3-4 khz. W 1,o4,, 2, 3 2 Thus the 1, 4, 5 cluster of audiograms hardly -- - differs from the three taken within the hour.not 1-2 khz (both ears).. A 222 23 20 only were the means similar, but the distribution of B 1-2 1-6 1-1 the individual subjects' variations was very similar 3-4 khz (both ears) A 1-6 1 9 1iS (Table 4). B -1 5-1*4-1*7 Discussion The position of audiometry in hearing conservation multiple attendances must be very substantial in programmes in Britain is far from established. The industry. Since Table 1 suggested that audiogram 2 hearing conservation programme of one large conwas likely to be a fair indication of the mean of cern requires that 'Any such applicant (for employnumbers 1, 2, and 3, this has also been shown in ment) should be finally accepted only after satis- Table 3 for comparison. factory audiometric examination and any offer of Not only are the means of the three audiogram employment should be made conditional upon TABLE 4 DISTRIBUTION OF NUMBERS OF MEN BY STATED VARIATION BETWEEN INDIVIDUAL AUDIOGRAMS Individual subjects' maximum variation between 3 readings (db) Total 0 1i 21 31 5 61 7i 81 10 111 12j men 1-2 khz (both ears) Works A Audiograms 1, 2, 3...... 9 30 15 13 1 1 69 1,4,5...... 5 19 24 14 6 1 69 Works B Audiograms 1, 2, 3...... 2 8 19 17 8 5 4 63 1, 4, 5...... 2 16 10 11 12 6 2 2 2 63 3-4 khz (both ears) Works A Audiograms 1, 2, 3...... 8 17 18 10 6 8 1 1 69 1,4,5...... 4 18 15 14 5 5 5 1 1 1 69 4 Works B Audiograms 1, 2, 3...... 5 7 15 11 10 5 4 3 2 1 63 1,4,5...... 5 7 16 8 12 4 6 3 1 0 1 63

274 B. P. R. Hartley, R. W. Howell, A. Sinclair, and D. A. D. Slattery satisfactory completion of hearing tests'; and 'Audiograms should be updated at intervals of one year' (Pelmear, 1973). At the same time Atherley (1972) suggests that current audiometry has limitations as a basis for medical standards; that a clear distinction between normal and abnormal is not always possible with this technique; that audiometry performed outside the laboratory, as perhaps in industry, might not always provide reliable results; and that it canbe shown numerically that even the most sensitive ears would have to be tested several times over a long period before any change could be accepted with confidence. Some justification for this last statement derives from the laboratory study of Atherley and Dingwall- Fordyce (1963). Additionally, Howell and Hartley (1972) concluded from their industrial study that with current variability in audiometric recording it seems unlikely that small changes in recorded hearing levels will give confident early indication of deterioration in a susceptible ear. Thus the case for widespread early or frequent serial audiometry is not presently strong. The pre-employment audiogram with aural examination may be useful to detect those whom it would be unwise, for medicolegal reasons at least, to place in noisy areas because of existing hearing levels or defects. Follow-up audiograms may help to detect an abnormally high rate of deterioration, but the cost-benefit of frequent audiograms has yet to be demonstrated in industry in the United Kingdom. The arbitrary period between audiograms, and the question of whether or not a single audiogram at each examination is reliable, may also drastically affect the cost of these exercises. It would be difficult and costly for a man to be released from work on a number of occasions within a short period. One of the additional difficulties would be getting the man at times when he is free of temporary threshold shift, and this difficulty would be enhanced if he had to make several attendances within a short period. If the concept of taking two audiograms at a single session is accepted, the avoidance of temporary threshold shift probably remains the major problem. Industries with a large employee turnover may find frequent routine audiometry expensive. Table 1 suggests that with the Peters audiometer there is a learning effect when three readings are taken within an hour. Some of the learning effect may well have lapsed by the fourth and fifth audiograms, so that threshold levels tend to revert to something of the order of the second test. This is true of the means both at 1 and 2 khz and at 3 and 4 khz. On the other hand, Delaney (1970), in small laboratory studies, found learning effect improvement even after 10 tests. He also found that the first audiometric test on each occasion is likely to give a mean hearing level about 1 db higher than second or subsequent tests on that day. Table 1 confirms this difference between first and second audiograms at the same session. For technical reasons at the time of the survey, readings at 3 and 4 khz were not available on the MMI machine, but readings at I and 2 khz suggest perhaps that the learning effect had reached a maximum on average by the second recording. The figures provide some evidence that using the same operator, variation in the individual subject over a relatively short period of time is not as great as might have been feared but is still a factor operating against the early detection of the sensitive ear. The mean individual variation at works A and B was less than the mean difference (at 3 and 4 khz) between their operators when using unexposed males of similar age and social class from the same geographical background. Tables 3 and 4 suggest that in the context of total audiometric variation in industry (Howell and Hartley, 1972) at both works and at both frequency groupings there was no great difference between the mean of three readings taken at a single session, the mean of three readings taken at separate attendances over a period of three weeks, and the second of three readings taken at one attendance. If these findings are confirmed elsewhere in industry then they are of great significance as industrial audiometry could be reliably limited to a single session for each examination. If it is generally accepted that small changes in threshold levels cannot be taken as a significant indication of either a susceptible or damaged ear, then on economic grounds it might be thought (Table 1) that a single audiometric reading might well be considered satisfactory. This would be especially so where there is continuity of operator. However, while a relatively small difference between these two readings is true of a series, Table 4 shows that the variation in individuals over three readings was occasionally as high as 12-5 db. The maximum variation between first and second readings was 11-25 db. It follows then that the single audiogram may well be misleading, particularly if it is a preemployment examination which will be used as a reference level at subsequent examinations. In only four out of 132 subjects did the second audiogram vary by more than 3 db from the average of the first three readings at 3 and 4 khz. A reasonable and economic conclusion to be drawn from this study might well be that a subject attending for audiometry should have two tests at the one examination and that in the absence of any large difference (say 5 db) between the two sets of readings, the second should be adopted. Any sizeable discrepancy would lead to further examination of the individual. Earlier results should not be available to the operator when tests are being carried out. Continuity of operator and monitoring the

Subject variability in short-term audiometric recording 275 operator's standards may well be an important factor in reducing variability (Howell and Hartley, 1972). The present study suggests that in any busy programme for noise-exposed men, the avoidance of temporary threshold shift may be more of a practical problem than the single-attendance examination. There was no evidence in this study that the MMI self-recording audiometer gave less variability than the manually operated Peters machine, using a single operator at each works. We are grateful to Dr. K. P. Duncan, Chief Medical Officer, for encouraging this study and to the three anonymous operators who made these conclusions possible. References Atherley, G. R. C. (1972). Personal communication. -, and Dingwall-Fordyce, I. (1963). The reliability of repeated auditory threshold determination. British Journal of Industrial Medicine, 20, 231-235. Burns, W., and Robinson, D. W. (1970). Hearing and Noise in Industry. H.M.S.O., London. Delaney, M. E. (1970). On the stability of auditory threshold. N.P.L. Aero Report Ac 44. Howell, R. W., and Hartley, B. P. R. (1972). Variability in audiometric recording. British Journal of Industrial Medicine, 29, 432435. Pelmear, P. L. (1973). Hearing conservation. Journal of the Society of Occupational Medicine, 23, 22-26. Received for publication July 27, 1972. Accepted for publication December 14, 1972. Requests for reprints to R. W. Howell. Br J Ind Med: first published as 10.1136/oem.30.3.271 on 1 July 1973. Downloaded from http://oem.bmj.com/ on 17 March 2019 by guest. Protected by copyright.