Tritanium PL Posterior Lumbar Cage

Similar documents
nvt Transforaminal Lumbar Interbody Fusion System

nvp Posterior Lumbar Interbody Fusion System

nva Anterior Lumbar Interbody Fusion System

Alamo T Transforaminal Lumbar Interbody System Surgical Technique

Tritanium PL Posterior Lumbar Cage

QIN4432TRICREV01. IMPORTANT PRODUCT INFORMATION FOR TRITANIUM C Cervical Cage. Version 1 1 STERILE PRODUCT

Posterior Lumbar Interbody Fusion System

Features & Benefits. 1) Wide Bone Graft Space. Anterior Margin 3mm Posterior Margin 1.5mm. Marker Margin

Royal Oak IBFD System Surgical Technique Posterior Lumbar Interbody Fusion (PLIF)

Alamo C. Cervical Interbody System Surgical Technique. An Alliance Partners Company

PLIF/TPLIF Cage System

IBD PEEK C. Anterior Cervical Spacer System. Surgical Technique

Cervical Spacer System surgical technique

EXACTECH SPINE. Operative Technique. Cervical Spacer System. Surgeon focused. Patient driven. TM

SURGICAL TECHNIQUE MANUAL. InterFuse T

OPERATIVE TECHNIQUE. CONSTRUX Mini PTC. Mini PTC Spacer System

Apache Cervical Interbody Fusion Device. Surgical Technique. Page of 13. LC-005 Rev F

TABLE OF CONTENTS. ShurFit Anterior Cervical Interbody Fusion (ACIF) System Overview 2. Implant Specifications 3. Instrument Features 4

Surgical Technique. Apache Posterior Lumbar Interbody Fusion Apache Transforaminal Lumbar Interbody Fusion

C-THRU Anterior Spinal System

PILLAR AL. Anterior Lumbar Interbody Fusion (ALIF) and Partial Vertebral Body Replacement (pvbr) PEEK Spacer System OPERATIVE TECHNIQUE

A U X I L I A R Y C O N N E C T O R S Surgical Technique

VTI INTERFUSE T SURGICAL TECHNIQUE FORWARD THINKING FOR THE BACK. 1/20

Surgical Technique. Apache Anterior Lumbar Interbody Fusion

HawkeyeTM Peek. surgical technique

product overview Implant heights range from 8mm-20mm in 2mm increments, with two lordocic angle options of 6 and 12.

CROSS -FUSE P E E K V B R / I B F SYST E M

TM TM Surgical Technique

INTELLIGENT SPINAL SYSTEM

T.L.I.F. Surgical Technique. Featuring the T.L.I.F. SG Instruments, VG2 PLIF Allograft, and the MONARCH Spine System.

VTI INTERFUSE S SURGICAL TECHNIQUE FORWARD THINKING FOR THE BACK.

Thoracolumbar Solutions. Zyston Curve. Interbody Spacer System. Surgical Technique Guide

Transforaminal Lumbar Interbody Fusion Cage (TLIF)

Surgical Technique Manual

EIT TLIF Cage. For Natural Bone Ingrowth with EIT Cellular Titanium

O.I.C. PEEK UniLIF Unilateral Lumbar Interbody Fusion

VTI INTERLINK PEDICLE SCREW SYSTEM

AVS TL PEEK Spacer System TLIF Surgical Technique. Friday, March 28, 2014 Chicago, IL

Solitaire Anterior Spinal System

Imola Lateral IBF System Surgical Technique

ACP. Anterior Cervical Plate System SURGICAL TECHNIQUE

AVS Navigator TLIF Surgical Technique

Thoracolumbar Solutions. Avenue T. TLIF Cage. with ertebridge PLATING TECHNOLOGY. Surgical Technique Guide

Royal Oak Cervical Plate System

Advantage ALIF. Keith Shevlin Managing Director

Veyron -C Anterior Cervical System Surgical Technique

ACP1 CERVICAL PLATE SPINAL SYSTEM SURGICAL TECHNIQUE GUIDE II.

Patient Information MIS LLIF. Lateral Lumbar Interbody Fusion Using Minimally Invasive Surgical Techniques

Surgical Technique. TraXis. Precision. Transforaminal Lumbar Interbody Fusion Spacer. The Art & Science of Spine Surgery

L-VARLOCK. Posterior Lumbar Cage with adjustable lordosis. S urgical T echnique

Fusion Device. Surgical Technique. Cervical Interbody Fusion with Trabecular Metal Technology

Ardis. Surgical Technique. Interbody System. Solutions by the people of Zimmer Spine. zimmerspine.com

Zimmer Facet Screw System Surgical Technique

Patient Information MIS LLIF. Lateral Lumbar Interbody Fusion Using Minimally Invasive Surgical Techniques

T.L.I.F. Transforaminal Lumbar Interbody Fusion

VLIFT System Overview. Vertebral Body Replacement System

Table of Contents.

Interbody fusion cage for the transforaminal approach. Travios. Surgical Technique

TraXis TLIF Interbody System

EFSPINE CERVICAL COMBINED SET DISC PROTHESIS ORGANIZER BOX

SURGICAL TECHNIQUE GUIDE TRESTLE. Anterior Cervical Plating System

TABLE OF CONTENTS. Vault C Anterior Cervical Discectomy 2 and Fusion (ACDF) System Overview. Implants 3. Instruments 5. Surgical Technique 10

Apache Interbody Surgical Technique. LC004 Rev F

AVS Anchor -L Lumbar Cage System Surgical Technique

T-PAL Spacer System. Transforaminal posterior atraumatic lumbar spacer system.

Lapidus Arthrodesis System Instructions for Use

TiLock XT Minimally Invasive Surgery (MIS) Pedicle Screw System

Y o u r Id e a s En g i n e e r e d t o Li f e

Thoracolumbar Solutions. TM Ardis. Interbody System. Surgical Technique Guide

Aesculap CeSpace TM PEEK and CeSpace TM XP Spinal Implant System Instructions for Use

SynCage. Surgical Technique. This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation.

OPERATIVE TECHNIQUE. anterior cervical plating system


Aero -C Anterior Cervical Interbody and Fixation System

Zimmer Anterior Buttress Plate System. Surgical Technique

Pinit Plate Small Bone Fusion System Bone Plate & Screw System

OPERATIVE TECHNIQUE PTC PEEK FORZA. spacer system

TiLock 2 Spinal System. Surgical Technique

InFix. Anterior Lumbar Device. Surgical Technique Guide

Cervical Solutions. Optio-C Anterior Cervical Plate. with Allograft/Autograft. Surgical Technique Guide

TiLock XT Minimally Invasive Surgery (MIS) Pedicle Screw System

T-PAL. Transforaminal Posterior Atraumatic Lumbar Cage System.

Technique Guide. T-PAL. Transforaminal posterior atraumatic lumbar spacer system.

AVS Anchor -C Cervical Cage System Surgical Technique

Technique Guide KISSloc Suture System

AVS ARIA TM Product Overview

BAK/C Cervical Anterior Interbody Fusion System

100 Interpace Parkway Parsippany, NJ

POSTERIOR SPINE TRUSS SYSTEM

Hinged Laminoplasty System surgical technique

The Fusion of. Strength, Design. Performance. and

SURGICAL TECHNIQUE ROI-T TM TLIF INTERSOMATIC IMPLANT TRANS-FORAMINAL APPROACH

PATHWAY PLIF and PATHWAY TLIF. SPINAL ELEMENTS PATHWAY PLIF And PATHWAY TLIF PATHWAY

Silverstone Interbody System Surgical Technique

UniVise Spinous Process Fixation Plate System. Surgical Technique. Simple, One-Piece Design Anatomically Shaped Plates Optimized Radial Spike Pattern

Technique Guide. ARCH Laminoplasty System. Dedicated System for Open-door Laminoplasty.

GIZA Surgical Technique

Gallery Laminoplasty Spine System

Transcription:

Tritanium PL Posterior Lumbar Cage

Table of contents Tritanium technology overview...3 Description...5 Step 1: Exposure open approach...6 Step 2: Preparation of facet joints...7 Step 3: Insertion site preparation: Facet sparing or transforaminal...8 Step 4: Distraction...8 Step 5: Discectomy and endplate preparation...9 Step 6a: Sizing the disc space with Tritanium Posterior Trial... 10 Step 6b: Sizing the disc space with AVS UniLIF Trial...12 Step 7: cage sizing and preparation... 13 Step 8: Assemble cage to Inserter... 16 Step 9: cage insertion... 17 Step 10: Placement of bone graft...20 Step 11: Posterior fusion... 21 Step 12: Closure...22 Step 13: Revision...22 sterile packaged cages...23 Instruments...26 Important product information tor cage...28 Acknowledgments: Stryker wishes to thank the following surgeons for their dedication and contributions to the development of the cage. Sigurd Berven, MD Wellington Hsu, MD Thomas Mroz, MD John Rhee, MD 2

Tritanium technology overview Tritanium is Stryker s proprietary titanium alloy material built using Laser Rapid Manufacturing (LRM). This material has been used to create a cage that consists of a unique configuration of both solid and porous material surfaces. Highly porous titanium alloy on top and bottom of implant and all sides of internal graft window Solid-tipped, precisely angled serrations on the superior and inferior surfaces designed for bidirectional fixation and to maximize surface area for endplate contact with the implant Smooth wedge nose to facilitate insertion Thin layer of solid material to provide smooth surface during insertion and reduce potential to catch soft tissue Large window to reduce stiffness of cage and help with assessment on different imaging modalities 3

The following technique describes the unilateral insertion of a single implant into the disc space through a posterior lumbar interbody fusion (PLIF) approach, transforaminal lumbar interbody fusion (TLIF) approach or anywhere in between based on the pathology being addressed and surgeon preference. This technique may be performed through an open, less invasive or minimally invasive procedure. Minimally invasive surgical procedures, without compromising surgical goals, may 1,2,3,4 : Reduce incision size Reduce blood loss Reduce infection Lead to faster patient recovery Reduce pain Reduce hospital stay Spare muscle (Multifidus) Reduce reoperations Note: This surgical technique is intended as a guide only. It is recommended that the surgeon be thoroughly trained before proceeding. The surgeon must consider the particular needs of each patient and make the appropriate adjustments when necessary and as required. 1 Peng CW, et al. Clinical and Radiological Outcomes of Minimally Invasive Versus Open Transforaminal Lumbar Interbody Fusion. SPINE 34: 1385-9, 2009. 2 Kim KT, Lee SH, et al. The Quantitative Analysis of tissue Injury Markers After Mini-Open Lumbar Fusion. SPINE 6: 712-6, 2006. 3 Wang MY, et al. Minimally invasive surgery for thoracolumbar spinal deformity: initial clinical experience with clinical and radiographic outcomes. NEUROSURG FOCUS 28 (3):E9, 2010. 4 Smith JS, et al. Rates of Infection After Spine Surgery Based on 108,419 Procedures: A Report from the Scoliosis Research Society Morbidity and Mortality Committee. SPINE Volume 36, Number 7: 556-563, 2011. Please refer to the Instructions For Use for complete information on indications, contraindications, precautions, warnings, potential adverse effects, sterilization and packaging. 4

Description The posterior lumbar cages are rectangularshaped interbody fusion devices intended for use as an aid in spinal fixation. These implants are constructed out of Stryker s proprietary Tritanium technology. Tritanium is a novel highly porous titanium material designed for bone in-growth and biological fixation. These implants are offered in a variety of widths, lengths, heights and lordotic angles designed to adapt to a variety of patient anatomies. The implants have serrations on the superior and inferior surfaces designed for bidirectional fixation and to maximize surface area for endplate contact with the implant. The implants have ergonomically shaped anterior edges to facilitate cage insertion with preservation of endplates and flat posterior edges. The implants have a large central opening spanning endplate to endplate for graft containment and to aid in fusion throughout the interbody cage. cage system is comprised of Tritanium PL cages as well as surgical instruments from other Stryker systems. 5

Step 1: Exposure open approach The patient is placed under anesthesia and positioned in the prone position prepped and draped in the usual sterile manner for posterior fusion with supplemental fixation (Figure 1). The surgical approach to implant a cage can be performed using a standard open, less invasive or minimally invasive procedure, from the patient s left or right side. Typically, cage insertion is performed from the symptomatic side in patients with radiculopathy or on the concavity in patients with segmental coronal deformity. This technique describes an open surgical procedure. Figure 1. Prone patient positioning This technique describes an open TLIF procedure placing a Tritanium PL cage obliquely across the disc space. The incision is made over the spinous process of the level above the index disc level and extends to the spinous process of the level below (Figure 2). Sharp paraspinal, subperiosteal dissection is performed exposing the facets of the level above and the facets at the operative level. Care must be taken to avoid damage to the facet capsules at the unfused level above. Unless the surgeon intends to perform concomitant intertransverse fusion, the transverse processes need not be exposed. Exposure to the tips of the transverse processes will permit a posterolateral fusion in addition to the interbody fusion. Figure 2. Incision for open surgical procedure 6

Note: The remaining steps in this surgical technique are similar in open, less invasive and minimally invasive PLIF and TLIF surgical procedures. All images in this technique guide depict an open procedure for image clarity. The cage system lends itself to minimally and less invasive techniques. These techniques rely on proprietary access systems and specialized tools, the use of which is best depicted in their individual technique guides. Please refer to Stryker s retractor system surgical technique guides, including LITe Pedicle Based Retractor, LITe Mid-Line Retractor and LITe Decompression Tubes, for additional information and detailed images on less invasive and minimally invasive PLIF and TLIF procedures. In a minimally invasive TLIF procedure, the incision may be made at the midline or approximately 4cm off midline with a more lateral trajectory in line with the disc space (Figure 3). Figure 3. Incision for MIS surgical procedure Step 2: Preparation of facet joints At the operative level, both facet capsules should be removed completely. This is typically accomplished using a cautery device. The facet is prepared for fusion by removing the articular cartilage from the facet joint with a burr, rongeur or other appropriate instrument (Figure 5). The inferior and superior articular facets are removed on the side of the TLIF. Complete facetectomy of the contralateral side may permit increased restoration of segmental lordosis. Figure 4. Intact spine Figure 5. Facet joint preparation 7

Step 3: Insertion site preparation: Facet sparing or transforaminal The cage may be inserted into the disc space using either a facet sparing (similar to a posterolumbar interbody fusion, PLIF) or a transforaminal (TLIF) approach. For the TLIF approach, at the appropriate level(s), an osteotome may be used to remove the inferior articular process of the cephalad vertebra. If an osteotome is used, this may be done with two cuts (Figure 6): One vertical cut just medial to the facet extending superiorly to the superior border of the facet One horizontal cut directed laterally towards the foramen Figure 6. TLIF site preparation Once both cuts are made, the inferior articulating process of the cephalad vertebra may be removed with a kerrison. The lateral edge of the ligamentum flavum can then be visualized. A curette may be used to release (but not resect) the ligamentum flavum from the superior lamina of caudal vertebra allowing for distraction. The ligamentum flavum may be preserved to minimize exposure of the neural elements, but resection of the ligamentum flavum is often required for adequate neural compression. Note: Always assess the need for distraction, even if minimal, to evaluate the disc space. Step 4: Distraction Effective distraction aids in removal of the superior articular process, decompression of the neuroforamen, preparation of the disc space and insertion of the Cage. This may be accomplished through several techniques: pedicle screw distraction, distraction between bony elements, and/or distraction with a positioning device. If pedicle screw distraction is chosen, the screws should be positioned at this time, using standard technique. Apply distraction between pedicle screws. Particularly in patients with less than ideal bone quality, it might be useful to size the interspace with paddle distractors, reamer distractors or trials before locking the distraction down through the pedicle screws. Interspace distraction helps provide a sense of restoration of annular tension and helps to avoid pedicle screw pre-loading (which may cause post-operative loosening). Choices for a supplemental spinal fixation system include, but are not limited to, Stryker s pedicle screw and rod or plate systems. Please refer to the surgical techniques of these supplemental fixation systems for additional information on implantation. Distraction should be removed when the implant is in the interbody space to minimize external compressive forces on the interbody space. 8 Precaution: Do not use the implant as the sole method for distraction, as this may cause damage to the implant.

Step 5: Discectomy and endplate preparation Access to the disc space is achieved through an annulotomy made lateral to the posterior longitudinal ligament. Using a scalpel, vertical cuts are made parallel to the dura and laterally in the foramen from the endplate of the cephalad vertebra to the endplate of the caudal vertebra. Additional cuts extend horizontally along the endplates of the vertebrae, connecting the vertical cuts (Figure 7). Access to the disc space may also be gained using an osteotome at the superior endplate of the lower vertebra. The annulus and any accessible disc material are removed with a pituitary rongeur (Figure 8). Figure 7. Annulotomy Figure 8. Discectomy and endplate preparation Note: The cages come in 9mm and 11mm width options. It is recommended that the annulotomy be at least as wide as the implant in order to facilitate insertion of the implant. If using a 9mm wide Tritanium PL cage, the annulotomy should be at least 9mm wide. If using an 11mm wide cage, the annulotomy should be at least 11mm wide. Note: Throughout the remainder of the procedure, care must be taken to avoid unintentional disruption of the remaining lateral, anterior or posterior annulus. If osteophytes are present, sharp excision with an osteotome or kerrison punch will provide a larger entry portal if desired. A curette, endplate shaver or narrow cobb elevator is used to elevate disc material from the endplates of the vertebral bodies. Angled curettes can also be used to elevate the disc from the endplates. An easily missed portion of the disc lies posteriorly and centrally within the disc space, just ventral to the spinal canal. Special effort should be directed to disc removal in this zone to provide optimal surface area for interbody fusion. Straight and angled pituitary rongeurs should be used to remove the disc. Additionally, multiple passes with the straight and angled curettes may be necessary to ensure adequate discectomy. Fluoroscopy may help in ensuring an adequate discectomy while limiting the risk of unintentional disruption to the ventral, lateral or posteromedial annulus. Note: Disc removal and endplate preparation instrumentation is available in the Reliance Total PLIF Instrument set, the Reliance LITe Instrument set and the LITe Decompression Instrument set. 9

Step 6a: Sizing the disc space with Tritanium Posterior Trial The disc space height can be sized using a series of paddle distractors, reamer distractors or trials. The paddle distractor, reamer distractor or trial size is serially increased until the appropriate fit within the disc space is achieved. The paddle distractor, reamer distractor or trial should fit snugly within the disc space with distraction released. Care must be taken to not damage the dense cancellous bony surface of the endplates to optimize the interface between the endplate and the implant (Figure 9). Tritanium Posterior Trial Figure 9. Sizing cage length using Tritanium Posterior Trial Tritanium Posterior Trials Choose a Tritanium Posterior Trial; attach it to the T-Handle, and insert it into the disc space. The trials are compatible with Stryker s posterior lumbar Tritanium interbody cages including the Posterior Lumbar Cage and Tritanium TL Curved Posterior Lumbar Cage. Trial lengths correspond to the and Tritanium TL T-Handle 48931000 Cage lengths and are measured from the tapered nose of the trial to the proximal end of the trial (Figure 10): 23mm to center of the hole 28mm to the back of the trial head 31mm to the front of the ring 35mm to the back of the ring Note: T-handle is compatible with Reliance Lite instrumentation, Aria Paddles/shavers, and Navigator Trials. Trial height 28mm 23mm 31mm 35mm Note: If using the Posterior Lumbar Cage, trials are line to line with the exception of the 32mm length cage. For a 32mm length cage, measure backwards 1mm from the front of the ring. 10 11mm Trial width Figure 10 Note: If using the Tritanium TL Curved Posterior Lumbar Cage and want to measure line to line for a 27mm length cage, measure 1mm forwards from the back of the trial head.

Trial to implant relationship based on lordotic orientation Anterior height Posterior height Tritanium TL Cage (back end view of cage where it attaches to inserter) Cage (side view of cage) Tritanium Posterior Trial (side view of trial) Note: Tritanium TL Cage lordosis is measured anterior to posterior. Note: Tritanium Posterior Trials measure line-to-line with the corresponding cage, i.e., a 7mm trial corresponds to a 7mm cage, measured from the tallest anterior point on the cage and inclusive of the teeth. It is important to not oversize the trial. Cage Tritanium TL Cage Length 23, 28 and 32mm 27, 31 and 35mm 0 Lordotic trial 6 Lordotic trial 12 Lordotic trial Width 11mm 11mm 11mm Height 6mm 7-14mm (1mm increments) 9-14mm (1mm increments) Note: Laser markings on the Tritanium Posterior Trials are designed to visually identify insertion depth. 4 = 40mm 5 = 50mm The line between 4 and 5 indicates 45mm depth. Laser markings will help identify the depth of trial within the disc space. Markings are measured from the tip of the trial head to the approximate center of the laser markings. Figure 11 Note: Trials are available with three built in lordosis options as indicated by a marking on the proximal end of the trial. The 0 and 6 trials do not have a black band on the proximal end. The 12 trials are identified by a black band on the proximal end (Figure 11). 11

Step 6b: Sizing the disc space with AVS UniLIF Trial The disc space height can be sized using a series of paddle distractors, reamer distractors or trials. The paddle distractor, reamer distractor or trial size is serially increased until the appropriate fit within the disc space is achieved. The paddle distractor, reamer distractor or trial should fit snugly within the disc space with distraction released. Care must be taken to not damage the dense cancellous bony surface of the endplate to optimize the interface between the endplate and the implant (Figure 12). AVS UniLIF Trial Figure 12. Sizing cage length using trial AVS UniLIF Trials Choose a Trial; attach it to the T-Handle, and insert it into the disc space. Width Height 0 Lordotic trial 9, 11mm 7-14mm (1mm increments) T-Handle 48361000 Note: The Trial footprint is available in all height and width offerings; however, it is only available in a length of 20mm. A ridge exists on the post of the trial at 25mm and 30mm, and is designed to assist the surgeon in determining which implant length is appropriate from radiographic images (Figure 13). Note: cages are available in 23mm, 28mm and 32mm lengths. Note: The Trials should be evaluated under fluoroscopic imaging to determine the proper fit and placement of the final implant. Figure 13 12

Note: If the surgeon utilizes the AVS Navigator Dynamic Distractor, 48394005, to determine the implant height, carefully and slowly expand the Dynamic Distractor as to not over distract the disc space or violate the endplates. Reference the AVS Navigator Surgical Technique Guide for instruction on assembly, use, disassembly, cleaning and sterilization (Figure 14). Extension Handle Dynamic Distractor 48394005 Extension Handle 48394006 Figure 14 Step 7: cage sizing and preparation Choose a cage that is equivalent to the final trial height or final distractor used. The implant sizing is based on the fit and feel of either the final Trial or distractor. Implant height should not be oversized. 13

How to open the pouch containing the cage The cages are sterile packaged. Select the appropriate implant size and verify before opening the packaging. To remove the cage from the pouch: 1. Remove the large flap from the cross strap. 2. Hold the top of the cutout with one hand while holding the smaller flap on the opposite side with the other. 3. Pull the top of the cutout and small flap away from each other until the pouch opens. 4. Remove the cage from the pouch. 14

To assemble the Inserter: 1. Remove the Inserter, including the Inner Shaft, from the Instrument Tray. Note: The PEEK Spacer Inserters from the AVS PL and UniLIF systems are the same Inserters used to implant the cages. Figure 15 Inserter Outer Shaft Inserter Inner Shaft 2. Place the threaded end of the Inner Shaft through the center opening on the back of the appropriate Inserter (Figure 15). Refer to the table to determine the appropriate Inserter used with the cage size selected by the surgeon. AVS PL Inserter 8-9 48350951 AVS PL Inserter 11 48350952 Length Width Height Inserter 23mm 9mm 7, 8mm Inserter 8-9 23mm 9mm 9-14mm Inserter 8-9 23mm 11mm 7, 8mm Inserter 8-9 23mm 11mm 9-14mm Inserter 11 28mm 9mm 7, 8mm Inserter 8-9 28mm 9mm 9-14mm Inserter 8-9 28mm 11mm 7, 8mm Inserter 8-9 28mm 11mm 9-14mm Inserter 11 32mm 9mm 9-14mm Inserter 8-9 32mm 11mm 7, 8mm Inserter 8-9 32mm 11mm 9-14mm Inserter 11 15

Step 8: Assemble cage to Inserter Align the threaded distal tip of the Inner Shaft with the threaded hole on the selected cage. Secure the cage to the Inserter by turning the knob on the Inner Shaft until the implant is tightly connected (Figure 16). Figure 16 Note: The AVS PL Inserter is held disassembled in the Instrument Tray for cleaning and sterilization purposes. Note: Make sure the Inner Shaft is completely seated by pressing down on the proximal end until the Inner Shaft bottoms out within the Inserter. This will allow the distal end of the Inner Shaft to fully protrude providing the necessary surface area to securely load the implant (Figure 17). Figure 17 16

Place the cage in the Graft Block, and pack it with autogenous or allogenic bone graft comprised of cancellous and/or corticocancellous bone graft using the Graft Compactor. The compacted graft should be flush with the upper and lower surfaces of the implant, to later be in contact with the endplates (Figure 18). Graft Block 48350963 Figure 18 Graft Compactor 48350923 Step 9: cage insertion (see images and warnings in Figures 20-22) Carefully insert the cage with the inserter in-line with the disc space and in the orientation that the cage is intended to sit as shown in Figure 19. When necessary, a mallet can be used to gently progress the cage. Avoid using the insertion techniques shown in Figures 20-22. The same methods and orientation above are to be used for intra-operative removal of the cage, when deemed medically necessary as described on page 20. Optimal positioning may be facilitated by directing the implant obliquely until it contacts the ventral annulus (Figure 19). Figure 19 Proper insertion If difficulty is encountered while inserting the implant, it most likely represents: Contralateral disc material which may be blocking passage of the implant Inadequate distraction An undersized annulotomy Oversized implant Check for adequacy of the discectomy; ensure that distraction is maintained, and remove the impediment. Then, continue to insert the implant. The distraction should be released to facilitate optimal placement of the implant. Figure 20 Do not twist Figure 21 Do not cantilever Figure 22 Do not rotate to achieve final position Precaution: Do not twist, cantilever or rotate to achieve final position. This may result in damage to the implant. 17

The recommended insertion angle for the obliquely lordotic PL implants is approximately 30 off midline. The circular dimple feature on the posterior end of the lordotic 28mm and 32mm implants is designed to help determine the orientation of the lordosis. To help ensure the lordosis is restored in the desired plane, the circular dimple must be towards the lateral aspects in an oblique insertion (Figure 23). Figure 23 Note: Nerves or the spinal cord could interfere with implant insertion - Retractors similar to the Reliance PL Nerve Root Retractors (48360300, 48360310 and 48360320) or Reliance LITe Penfields (48066104 and 48066204) can be used. Reliance PL Nerve Root Retractors 48360300, 48360310, 48360320 Reliance LITe Penfields 48066104, 48066204 Note: To visually confirm the lordosis is restored in the desired plane, the implant must be inserted with the circular dimple feature towards the lateral aspects in an oblique insertion. Note: Fluoroscopy may be useful in determining the appropriate trajectory for insertion of the implant and appropriate final positioning. Care should be taken to prevent the instrument from pushing too far anteriorly. Caution: In patients with compromised bone integrity, be mindful that the implant is in apposition to dense bone to maximize distraction of the interbody space and to avoid possible implant subsidence. With the desired position achieved, detach the AVS PL Inserter from the implant by turning the knob on the Inner Shaft in a counterclockwise direction. Keep inserter in position until knob is completely disengaged and removed from the inserter. Based on surgeon preference, the PL Impactor or the AVS Navigator Footed Tamp may be used to gently tamp the implant to its final position. Figure 24 Insertion angle PL Impactor 48350911 AVS Navigator Footed Tamp 48393007 18

Note: The cage can be used for a traditional PLIF approach inserted in-line with two implants placed in a straight orientation bilaterally within the disc space (Figure 25). Figure 25 The correct position of the implant should be confirmed by direct visualization of implant location and/or with lateral and anteriorposterior fluoroscopic images (Figures 26 and 27). Figure 26 Figure 27 19

For intraoperative removal of the cage, when deemed medically necessary, perform distraction seen in Figure 19 on page 17. Use the AVS PL Inserter still attached to the implant to remove the cage from the disc space. If needed, a mallet or slap hammer can be used. If possible, removal should be performed in-line and in the same trajectory that the implant was inserted. If the cage has been removed intraoperatively, it should not be re-inserted into the disc space as this may affect the performance of the implant. Step 10: Placement of bone graft Autograft and/or allogenic bone graft may be placed in the interbody space prior to insertion of the implant. The cage should be filled with bone graft prior to insertion. Additional bone graft may be placed lateral or dorsal to the implanted cage. 20

Step 11: Posterior fusion The cages are to be used with supplemental fixation that is intended for use in the lumbosacral spine. If pedicle screws were not inserted earlier in the procedure, insert pedicle screws at this point or other appropriate supplemental fixation. Compression of the pedicle screws or interspinous device may be used to create segmental lordosis of the segment fused (Figure 28). Cage and Xia 3 or Xia 4.5 Cage and ES2 Cage and UniVise Figure 28 The remaining bone graft may be placed in the decorticated facets to promote fusion. Intraoperative coronal and sagittal radiographic views should be used to confirm satisfactory position of the cage, supplemental fixation and bone graft. Note: Choices for supplemental spinal fixation systems include, but are not limited to, Stryker s pedicle screw or interspinous process fixation plate systems (Xia, Radius, Trio, Techtonix, UniVise and ES2). Please refer to the respective surgical techniques of the above mentioned supplemental fixation systems for additional information on implantation. 21

Step 12: Closure Check the foramen and TLIF site for any bone fragments or extraneous soft tissue. Once satisfactory decompression of the exiting and traversing nerve roots is confirmed, the wound should be closed in a routine manner. Step 13: Revision A surgical revision may be indicated for many reasons including new or unresolved pain or neurological symptoms, changes in implant positioning, non-union or incomplete fusion, etc. If necessary, the cage can be removed with the use of the AVS PL Inserter and a mallet or slap hammer. The surgeon must use his/her professional judgment to determine the appropriate revision strategy taking into consideration the patient s health, the nature of the problem and/or implant failure, the patient s bone quality and the surgeon s expertise with other spinal treatments and instrumentation. Revision guidelines: 1. Soft tissue around the surface of the implant should be removed. 2. An osteotome or rongeurs can be used to remove any bony tissue secured to the implant. 3. The AVS PL Inserter is reattached to the implant to remove it from the surgical site. 4. A mallet or slap hammer can be used to aid in withdrawal of the implant. Alternatively, if the AVS PL Inserter cannot be reattached to the implant, forceps or other manual surgical instruments may be used to grasp and extract the implant. 22

sterile packaged cages Length: 23mm Width: 9mm Width: 11mm 0 6 applied from tip to distal end of cage 12 applied from tip to distal end of cage 0 6 applied from tipto distal end of cage 12 applied from tip to distal end of cage Reference number Description Height x Length x - Width 48950070 7 x 23 x 0-9 Posterior Lumbar Cage 48950080 8 x 23 x 0-9 Posterior Lumbar Cage 48950090 9 x 23 x 0-9 Posterior Lumbar Cage 48950100 10 x 23 x 0-9 Posterior Lumbar Cage 48950110 11 x 23 x 0-9 Posterior Lumbar Cage 48950120 12 x 23 x 0-9 Posterior Lumbar Cage 48950130 13 x 23 x 0-9 Posterior Lumbar Cage 48950140 14 x 23 x 0-9 Posterior Lumbar Cage 48950076 7 x 23 x 6-9 Posterior Lumbar Cage 48950086 8 x 23 x 6-9 Posterior Lumbar Cage 48950096 9 x 23 x 6-9 Posterior Lumbar Cage 48950106 10 x 23 x 6-9 Posterior Lumbar Cage 48950116 11 x 23 x 6-9 Posterior Lumbar Cage 48950126 12 x 23 x 6-9 Posterior Lumbar Cage 48950136 13 x 23 x 6-9 Posterior Lumbar Cage 48950146 14 x 23 x 6-9 Posterior Lumbar Cage 48950092 9 x 23 x 12-9 Posterior Lumbar Cage 48950102 10 x 23 x 12-9 Posterior Lumbar Cage 48950112 11 x 23 x 12-9 Posterior Lumbar Cage 48950122 12 x 23 x 12-9 Posterior Lumbar Cage 48950132 13 x 23 x 12-9 Posterior Lumbar Cage 48950142 14 x 23 x 12-9 Posterior Lumbar Cage 48951070 7 x 23 x 0-11 Posterior Lumbar Cage 48951080 8 x 23 x 0-11 Posterior Lumbar Cage 48951090 9 x 23 x 0-11 Posterior Lumbar Cage 48951100 10 x 23 x 0-11 Posterior Lumbar Cage 48951110 11 x 23 x 0-11 Posterior Lumbar Cage 48951120 12 x 23 x 0-11 Posterior Lumbar Cage 48951130 13 x 23 x 0-11 Posterior Lumbar Cage 48951140 14 x 23 x 0-11 Posterior Lumbar Cage 48951076 7 x 23 x 6-11 Posterior Lumbar Cage 48951086 8 x 23 x 6-11 Posterior Lumbar Cage 48951096 9 x 23 x 6-11 Posterior Lumbar Cage 48951106 10 x 23 x 6-11 Posterior Lumbar Cage 48951116 11 x 23 x 6-11 Posterior Lumbar Cage 48951126 12 x 23 x 6-11 Posterior Lumbar Cage 48951136 13 x 23 x 6-11 Posterior Lumbar Cage 48951146 14 x 23 x 6-11 Posterior Lumbar Cage 48951092 9 x 23 x 12-11 Posterior Lumbar Cage 48951102 10 x 23 x 12-11 Posterior Lumbar Cage 48951112 11 x 23 x 12-11 Posterior Lumbar Cage 48951122 12 x 23 x 12-11 Posterior Lumbar Cage 48951132 13 x 23 x 12-11 Posterior Lumbar Cage 48951142 14 x 23 x 12-11 Posterior Lumbar Cage 23

Length: 28mm Width: 9mm Width: 11mm 0 6 applied obliquely across the cage Lordotic angle 12 Lordotic angle applied obliquely across the cage 0 6 applied obliquely across the cage 12 applied obliquely across the cage Reference number Description Height x Length x - Width 48952070 7 x 28 x 0-9 Posterior Lumbar Cage 48952080 8 x 28 x 0-9 Posterior Lumbar Cage 48952090 9 x 28 x 0-9 Posterior Lumbar Cage 48952100 10 x 28 x 0-9 Posterior Lumbar Cage 48952110 11 x 28 x 0-9 Posterior Lumbar Cage 48952120 12 x 28 x 0-9 Posterior Lumbar Cage 48952130 13 x 28 x 0-9 Posterior Lumbar Cage 48952140 14 x 28 x 0-9 Posterior Lumbar Cage 48954076 7 x 28 x 6-9 Posterior Lumbar Cage 48954086 8 x 28 x 6-9 Posterior Lumbar Cage 48954096 9 x 28 x 6-9 Posterior Lumbar Cage 48954106 10 x 28 x 6-9 Posterior Lumbar Cage 48954116 11 x 28 x 6-9 Posterior Lumbar Cage 48954126 12 x 28 x 6-9 Posterior Lumbar Cage 48954136 13 x 28 x 6-9 Posterior Lumbar Cage 48954146 14 x 28 x 6-9 Posterior Lumbar Cage 48952092 9 x 28 x 12-9 Posterior Lumbar Cage 48952112 11 x 28 x 12-9 Posterior Lumbar Cage 48952132 13 x 28 x 12-9 Posterior Lumbar Cage 48953070 7 x 28 x 0-11 Posterior Lumbar Cage 48953080 8 x 28 x 0-11 Posterior Lumbar Cage 48953090 9 x 28 x 0-11 Posterior Lumbar Cage 48953100 10 x 28 x 0-11 Posterior Lumbar Cage 48953110 11 x 28 x 0-11 Posterior Lumbar Cage 48953120 12 x 28 x 0-11 Posterior Lumbar Cage 48953130 13 x 28 x 0-11 Posterior Lumbar Cage 48953140 14 x 28 x 0-11 Posterior Lumbar Cage 48955076 7 x 28 x 6-11 Posterior Lumbar Cage 48955086 8 x 28 x 6-11 Posterior Lumbar Cage 48955096 9 x 28 x 6-11 Posterior Lumbar Cage 48955106 10 x 28 x 6-11 Posterior Lumbar Cage 48955116 11 x 28 x 6-11 Posterior Lumbar Cage 48955126 12 x 28 x 6-11 Posterior Lumbar Cage 48955136 13 x 28 x 6-11 Posterior Lumbar Cage 48955146 14 x 28 x 6-11 Posterior Lumbar Cage 48953092 9 x 28 x 12-11 Posterior Lumbar Cage 48953102 10 x 28 x 12-11 Posterior Lumbar Cage 48953112 11 x 28 x 12-11 Posterior Lumbar Cage 48953122 12 x 28 x 12-11 Posterior Lumbar Cage 48953132 13 x 28 x 12-11 Posterior Lumbar Cage 48953142 14 x 28 x 12-11 Posterior Lumbar Cage 24

Reference number Description Height x Length x - Width Width: 9mm Lordotic angle 12 applied obliquely across the cage 48957092 9 x 32 x 12-9 Posterior Lumbar Cage 48957112 11 x 32 x 12-9 Posterior Lumbar Cage 48957132 13 x 32 x 12-9 Posterior Lumbar Cage Length: 32mm Width: 11mm 6 applied obliquely across the cage 12 applied obliquely across the cage 48956076 7 x 32 x 6-11 Posterior Lumbar Cage 48956086 8 x 32 x 6-11 Posterior Lumbar Cage 48956096 9 x 32 x 6-11 Posterior Lumbar Cage 48956106 10 x 32 x 6-11 Posterior Lumbar Cage 48956116 11 x 32 x 6-11 Posterior Lumbar Cage 48956126 12 x 32 x 6-11 Posterior Lumbar Cage 48956136 13 x 32 x 6-11 Posterior Lumbar Cage 48956146 14 x 32 x 6-11 Posterior Lumbar Cage 48956092 9 x 32 x 12-11 Posterior Lumbar Cage 48956102 10 x 32 x 12-11 Posterior Lumbar Cage 48956112 11 x 32 x 12-11 Posterior Lumbar Cage 48956122 12 x 32 x 12-11 Posterior Lumbar Cage 48956132 13 x 32 x 12-11 Posterior Lumbar Cage 48956142 14 x 32 x 12-11 Posterior Lumbar Cage 25

Instruments Reference number Description 48350951 AVS PL Inserter 8-9, including Inner Shaft 48350952 AVS PL Inserter 11, including Inner Shaft 48350923 AVS PL Peek Spacer Graft Compactor 48350911 AVS PL Peek Spacer Impactor Straight 48361000 AVS T-Handle 48931000 T Handle 48350963 AVS PL Graft Block 48352207 AVS UniLIF Trial 7 x 20 x 0-9 48352208 AVS UniLIF Trial 8 x 20 x 0-9 48352209 AVS UniLIF Trial 9 x 20 x 0-9 48352210 AVS UniLIF Trial 10 x 20 x 0-9 48352211 AVS UniLIF Trial 11 x 20 x 0-9 48352212 AVS UniLIF Trial 12 x 20 x 0-9 48352213 AVS UniLIF Trial 13 x 20 x 0-9 48352214 AVS UniLIF Trial 14 x 20 x 0-9 48352107 AVS UniLIF Trial 7 x 20 x 0-11 48352108 AVS UniLIF Trial 8 x 20 x 0-11 48352109 AVS UniLIF Trial 9 x 20 x 0-11 48352110 AVS UniLIF Trial 10 x 20 x 0-11 48352111 AVS UniLIF Trial 11 x 20 x 0-11 48352112 AVS UniLIF Trial 12 x 20 x 0-11 48352113 AVS UniLIF Trial 13 x 20 x 0-11 48352114 AVS UniLIF Trial 14 x 20 x 0-11 26

Reference number Description 48934006 6mm, 0 Tritanium Posterior Trial 48934007 7mm, 6 Tritanium Posterior Trial 48934008 8mm, 6 Tritanium Posterior Trial 48934009 9mm, 6 Tritanium Posterior Trial 48934010 10mm, 6 Tritanium Posterior Trial 48934011 11mm, 6 Tritanium Posterior Trial 48934012 12mm, 6 Tritanium Posterior Trial 48934013 13mm, 6 Tritanium Posterior Trial 48934014 14mm, 6 Tritanium Posterior Trial 48934209 9mm, 12 Tritanium Posterior Trial 48934210 10mm, 12 Tritanium Posterior Trial 48934211 11mm, 12 Tritanium Posterior Trial 48934212 12mm, 12 Tritanium Posterior Trial 48934213 13mm, 12 Tritanium Posterior Trial 48934214 14mm, 12 Tritanium Posterior Trial 48350002 AVS Instrument Base 48350003 AVS Instrument Insert 48350004 AVS Instrument Container Lid 48930002 Tritanium Posterior Trials Container 48930002A Tritanium Posterior Trials Container Lid 48930002B Tritanium Posterior Trials Container Base 48930002C Tritanium Posterior Trials Container Insert 27

Important product information tor Sterile product Material The cages are manufactured out of Titanium Alloy Ti6Al4V (ASTM F1472). U.S.A and Canada Indications The cage is an intervertebral body fusion device indicated for use with autograft and/or allogenic bone graft comprised of cancellous and/or corticocancellous bone graft when used as an adjunct to fusion in patients with degenerative disc disease (DDD) at one level or two contiguous levels from L2 to S1. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). These patients should be skeletally mature and have six months of nonoperative therapy. Additionally, the cage can be used as an adjunct to fusion in patients diagnosed with degenerative scoliosis. The cage is to be implanted via a posterior approach. The cage is intended to be used with supplemental spinal fixation systems that have been cleared for use in the lumbosacral spine. Indications Outside U.S.A. and Canada The cage is an intervertebral body fusion device indicated for the treatment of spondylolisthesis, degenerative spine disorders and discal and vertebral instability, and may also be used in cases of spine revision surgery. Packing bone graft material within the implant is recommended. The cage is to be implanted via a posterior approach. The cage is intended for use with supplemental fixation. General conditions of use The implantation of intervertebral body fusion devices must be performed only by experienced spinal surgeons having undergone the necessary specific training in the use of such systems because this is a technically demanding procedure presenting a risk of serious injury to the patient. The information contained in the Package Insert is necessary but not sufficient for the use of this device. This information is in no sense intended as a substitute for the professional judgment, skill and experience of the surgeon in careful patient selection, preoperative planning and device selection, knowledge of the anatomy and biomechanics of the spine, understanding of the materials and the mechanical characteristics of the implants used, training and skill in spinal surgery and the use of associated instruments for implantation, securing the patient s cooperation in following an appropriately defined post-operative management program and conducting scheduled post-operative follow-up examinations. Caution Federal law (U.S.A.) restricts this device to sale by or on the order of a licensed physician. This device is not intended for anterior surgical implantation. This device is provided STERILE. Do not use if package is opened or damaged or after the Use by date on the label has expired. The cages have not been evaluated for safety and compatibility in the MR environment. cages have not been tested for heating or migration in the MR environment. Based on the fatigue testing results, the physician/surgeon must consider the levels of implantation, patient weight, patient activity level, other patient conditions, etc. which may impact the performance of the intervertebral body fusion device. The implantation of the intervertebral body fusion device must be performed only by experienced spinal surgeons with specific training in the use of this device because this is a technically demanding procedure presenting a risk of serious injury to the patient. Potential risks identified with the use of this intervertebral body fusion device, which may require additional surgery, include: device component fracture, loss of fixation, pseudoarthrosis (i.e. non-union), fracture of the vertebrae, neurological injury, and vascular or visceral injury. Patients with previous spinal surgery at the level(s) to be treated may have different clinical outcomes compared to those without a previous surgery. The components of the system should not be used with components of any other system or manufacturer. Any such use will negate the responsibility of Stryker for the performance of the resulting mixed component implant. Do not mix metals (e.g. Titanium based devices with stainless steel items). Some corrosion occurs on all implanted metals and alloys. Contact of dissimilar metals, however, may accelerate corrosion. Corrosion may accelerate fatigue fracture of implants, and cause metal compounds to be released into the body. Infection Transient bacteremia can occur in daily life. Dental manipulation, endoscopic examination and other minor surgical procedures have been associated with transient bacteremia. To help prevent infection at the implant site, it may be advisable to use antibiotic prophylaxis before and after such procedures. Instruments Instruments are provided by Stryker and must be used to assure accurate implantation of the device. While rare, intraoperative fracture or breakage of 28

instruments can occur. Instruments which have experienced extensive use or extensive force are more susceptible to fracture depending on the operative precaution, number of procedures, and disposal attention. Instruments must be examined for wear or damage prior to surgery. Reuse Never reuse or re-implant spinal surgical implants. These could become contaminated resulting in infection. In addition, even though the device appears undamaged, it may have small defects which could compromise structural integrity reducing its service life and/or leading to patient injury. Surgeons must verify that the instruments are in good condition and operating order prior to use during surgery. Handling Correct handling of the implant is extremely important. The operating surgeon must avoid notching or scratching the device. Allergy and hypersensitivity to foreign bodies When hypersensitivity is suspected or proven, it is highly recommended that the tolerance of the skin to the materials that make up the implants be checked before they are implanted. Contraindications Contraindications may be relative or absolute. The choice of a particular device must be carefully weighed against the patient s overall evaluation. Circumstances listed below may reduce the chances of a successful outcome: The cage should not be implanted in patients with an active infection at the operative site. The cage is not intended for use except as indicated. Marked local inflammation. Any abnormality present which affects the normal process of bone remodeling including, but not limited to, severe osteoporosis involving the spine, bone absorption, osteopenia, primary or metastatic tumors involving the spine, active infection at the site or certain metabolic disorders affecting osteogenesis. Any mental or neuromuscular disorder which would create an unacceptable risk of fixation failure or complications in postoperative care. Open wounds. Pregnancy. Inadequate tissue coverage over the operative site. Any neuromuscular deficit which places an unsafe load level on the device during the healing period. Obesity. An overweight or obese patient can produce loads on the spinal system which can lead to failure of the fixation of the device or to failure of the device itself. A condition of senility, mental illness, or substance abuse. These conditions, among others, may cause the patient to ignore certain necessary limitations and precautions in the use of the implant, leading to failure or other complications. Foreign body sensitivity. Where material sensitivity is suspected, appropriate tests must be made prior to material selection or implantation. Other medical or surgical condition which would preclude the potential benefit of spinal implant surgery, such as the presence of tumors, congenital abnormalities, elevation of sedimentation rate unexplained by other diseases, elevation of white blood cell count (WBC), or marked left shift in the WBC differential count. Prior fusion at the levels to be treated. These contraindications may be relative or absolute and must be taken into account by the physician when making his decision. The above list is not exhaustive. Surgeons must discuss the relative contraindications with the patients. Information for patients The surgeon must discuss all physical and psychological limitations inherent to the use of the device with the patient. This includes the rehabilitation regimen, physical therapy, and wearing an appropriate orthosis as prescribed by the physician. Particular discussion should be directed to the issues of premature weight bearing, activity levels, and the necessity for periodic medical follow-up. The surgeon must warn the patient of the surgical risks and make them aware of possible adverse effects. The surgeon must warn the patient that the device cannot and does not replicate the flexibility, strength, reliability or durability of normal healthy bone, that the implant can break or become damaged as a result of strenuous activity or trauma, and that the device may need to be replaced in the future. If the patient is involved in an occupation or activity which applies inordinate stress upon the implant (e.g., substantial walking, running, lifting, or muscle strain) the surgeon must advise the patient that resultant forces can cause failure of the device. Patients who smoke have been shown to have an increased incidence of non-unions. Such patients should be advised of this fact and warned of the potential consequences. For patients with degenerative disease, the progression of degenerative disease may be so advanced at the time of implantation that it may substantially decrease the expected useful life of the appliance. In such cases, orthopaedic devices may be considered only as a delaying technique or to provide temporary relief. Patients with previous spinal surgery at the level(s) to be treated may have different clinical outcomes compared to those without a previous surgery. Pre-operative precautions The surgical indication and the choice of implants must take into account certain important criteria such as: Patients involved in an occupation or activity that applies excessive loading upon the implant (e.g., substantial walking, running, lifting, or muscle strain) may be at increased risk for failure of the fusion and/or the device. Surgeons must instruct patients in detail about the limitations of the implants, including, but not limited to, the impact of excessive loading through patient weight or activity, and be taught to govern their activities accordingly. The procedure will not restore function to the level expected with a normal, healthy spine, and the patient should not have unrealistic functional expectations. 29

A condition of senility, mental illness, chemical dependence or alcoholism. These conditions among others may cause the patients to ignore certain necessary limitations and precautions in the use of the implant, leading to failure and other complications. Foreign body sensitivity. Where material sensitivity is suspected appropriate tests should be made prior to material implantation. Surgeons must advise patients who smoke have been shown to have an increased incidence of non-unions. Such patients must be advised of this fact and warned of the potential consequences. Care must be taken to protect the components from being marred, nicked, or notched as a result of contact with metal or abrasive objects. The choice of implants The choice of proper shape, size and design of the implant for each patient is crucial to the success of the surgery. The surgeon is responsible for this choice, which depends on each patient. Patients who are overweight may be responsible for additional stresses and strains on the device which can speed up implant fatigue and/or lead to deformation or failure of the implants. The size and shape of the bone structures determine the size, shape and type of the implants. Once implanted, the implants are subjected to stresses and strains. These repeated stresses on the implants must be taken into consideration by the surgeon at the time of the choice of the implant, during implantation as well as in the post-operative follow-up period. Indeed, the stresses and strains on the implants may cause fatigue, fracture or deformation of the implants, before the bone graft has become completely consolidated. This may result in further side effects or necessitate the early removal of the osteosynthesis device. Intra-operative precautions The insertion of the implants must be carried out using instruments designed and provided for this purpose and in accordance with the specific implantation instructions for each implant. Those detailed instructions are provided in the surgical technique brochure supplied by Stryker. Discard all damaged or mishandled implants. Never reuse an implant, even though it may appear undamaged. Do not use the implant as the sole method for distraction, as this may cause damage to the implant. Do not twist, cantilever or perform a twist/distract method of insertion. This may result in damage to the implant. Patient care following treatment Prior to adequate maturation of the fusion mass, implanted spinal instrumentation may need additional help to accommodate full load bearing. External support may be recommended by the physician from two to four months postoperatively or until x-rays or other procedures confirm adequate maturation of the fusion mass; external immobilization by bracing or casting may be employed. Surgeons must instruct patients regarding appropriate and restricted activities during consolidation and maturation for the fusion mass in order to prevent placing excessive stress on the implants which may lead to fixation or implant failure and accompanying clinical problems. Surgeons must instruct patients to report any unusual changes of the operative site to his/her physician. The physician must closely monitor the patient if a change at the site has been detected. Adverse effects Include but are not limited to: Late bone fusion or no visible fusion mass and pseudarthrosis; While the expected life of spinal implant components is difficult to estimate, it is finite. These components are made of foreign materials which are placed within the body for the potential fusion of the spine and reduction of pain. However, due to the many biological, mechanical and physicochemical factors which affect these devices but cannot be evaluated in vivo, the components cannot be expected to indefinitely withstand the activity level and loads of normal healthy bone; Superficial or deep-set infection and inflammatory phenomena; Allergic reactions to the implanted materials, although uncommon, can occur; Decrease in bone density due to stress shielding; Dural leak requiring surgical repair; Peripheral neuropathies, nerve damage, heterotopic bone formation and neurovascular compromise, including paralysis, loss of bowel or bladder function, or foot-drop may occur. Cessation of growth of the fused portion of the spine; Loss of proper spinal curvature, correction, height and/or reduction; Delayed Union or Nonunion: Internal fixation appliances are load sharing devices which are used to obtain alignment until normal healing occurs. In the event that healing is delayed, does not occur, or failure to immobilize the delayed/ nonunion results, the implant will be subject to excessive and repeated stresses which can eventually cause loosening, bending or fatigue fracture. The degree or success of union, loads produced by weight bearing, and activity levels will, among other conditions, dictate the longevity of the implant. If a nonunion develops or if the implants loosen, bend or break, the device(s) must be revised or removed immediately before serious injury occurs; Neurological and spinal dura mater lesions from surgical trauma; Early loosening may result from inadequate initial fixation, latent infection, premature loading of the device or trauma. Late loosening may result from trauma, infection, biological complications or mechanical problems, with the subsequent possibility of bone erosion, or pain. Serious complications may occur with any spinal surgery. These complications include, but are not 30