Risk of Axillary Nerve Injury in Standard Anterolateral Approach of Shoulder: Cadaveric Study

Similar documents
Re-definition of position and calculation of safe area for axillary nerve in deltoid muscle with its clinical relevance: a cadaveric study

STUDY OF VARIATIONS IN THE ORIGIN OF AXILLARY NERVE FROM THE POSTERIOR CORD OF BRACHIAL PLEXUS AND ITS CLINICAL IMPORTANCE

Percutaneous Humeral Fracture Repair Surgical Technique

Anatomical Considerations Regarding the Posterior Interosseous Nerve During Posterolateral Approaches to the Proximal Part of the Radius *

P.R.C.T II FIXATION PLATE FOR ARTICULAR FRACTURE OF THE PROXIMAL HUMERUS SURGICAL TECHNIQUE

Open reduction; plate fixation 1 Principles

Malaysian Orthopaedic Journal 2018 Vol 12 No 2

Incidence of traumatic axillary nerve injury after glenohumeral dislocation and fractures of the proximal humerus in Mansoura Emergency Hospital

Surgical Technique. Proximal Humerus Locking Plate

Minimally Invasive Plating of Fractures:

Co-Innervation of Triceps Brachii Muscle with Variant Branch of Ulnar Nerve

NCB Proximal Humerus Plating System

The study of distal ¼ diaphyseal extra articular fractures of humerus treated with antegrade intramedullary interlocking nailing

Index. B Backslap technique depth assessment, 82, 83 diaphysis distal trocar, 82 83

Double Engine Orthopedic Bone Nail System Universal Humeral Nail

LCP Percutaneous Aiming System 3.5 for PHILOS. For less invasive surgery at the proximal humerus.

Orthopedics in Motion Tristan Hartzell, MD January 27, 2016

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

Minimally Invasive Helical Plating for Shaft of Humerus Fractures: Technique and Outcome

Subpectoral Biceps Tenodesis using Cortical Buttons Surgical Technique

System. Humeral Nail. Surgical Technique

THE HUMERUS 20 THE HUMERUS* CROSS SECTION CROSS SECTION SUPERIOR VIEW

Technique. Aequalis Resurfacing Humeral Head

Section: Orthopaedics. Original Article INTRODUCTION

Upper extremity. Part I

Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture Is it possible? A cadaveric study and preliminary report

Diaphyseal Humerus Fractures. OTA Course Dallas, TX 1/20/17 Ellen Fitzpatrick MD

Research Article A Novel Surgical Approach to Lipomatous Tumours of the Deltoid Region

Assessment of Approximate Glenoid Size in Thai People

Review Article Meta-analysis comparing deltoid-splitting approach with deltopectoral approach for treatment of proximal humeral fractures

Proximal Humerus Fractures

Lateral femoral traction pin entry: risk to the. femoral artery and other medial neurovascular structures

A novel method of treating isolated unicondylar fracture of the head of the proximal phalanx: A case report

Aesculap Targon FN. Head Preserving Solution for Medial Femoral Neck Fractures. Aesculap Orthopaedics

Fractures and dislocations around elbow in adult

3.5 mm Clavicle Hook Plates

REHABILITATION FOR SHOULDER FRACTURES & SURGERIES. Clavicle fractures Proximal head of humerus fractures

Open Reduction Internal Fixation of Posterior Malleolus Fractures and Iatrogenic Injuries: A Cadaveric Study

Technique Guide. 3.5 mm LCP Periarticular Proximal Humerus Plate. Part of the Synthes locking compression plate (LCP) system.

ICUC Paper. Variable Angle Locked Screw (VAL): from concept to application. A. Fernández Dell'Oca, P. Regazzoni, S.M. Perren.

PROXIMAL HUMERUS FRACTURE TSHT 2017

LCP Periarticular Proximal Humerus Plate 3.5. The anatomic fixation system with anterolateral shaft placement.

Integra. Proximal Humeral Fracture Plate CASE STUDY

Conventus CAGE PH Surgical Techniques

Proximal Humerus Fractures: contemporary perspectives

Displaced Supracondylar Humerus Fractures in Children Are They All Identical?

Humeral SuturePlate. Surgical Technique

Shoulder Trauma (Fractures and Dislocations)

Anatomic Structures at Risk When Utilizing an Intramedullary Nail for Distal Fibular Fractures: A Cadaveric Study.

TORNIER BIO-RSA. Bony Increased Offset - Reversed Shoulder Arthroplasty SURGICAL TECHNIQUE

Elbow Hinge Fixator. Guided Flexion/Extension for Unstable Elbow Fractures.

OPERATIVE TECHNIQUE GALAXY FIXATION SHOULDER

TABLE OF CONTENTS. 2 (8144 Rev 2)

3.5 mm LCP Clavicle Hook Plates

Polarus 3 Solution Plates and Nails. Surgical Technique 4.3. Screws

A lateral approach to the distal humerus following identification of the cutaneous branches of the radial nerve

LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius.

Biomedical Research 2017; 28 (14): ISSN X

EVIDENCE BASED MEDICINE VOICE

The anteromedial approach for shoulder arthroplasty: The importance of the anterior deltoid

AcUMEDr. LoCKING CLAVICLE PLATE SYSTEM

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

The Distal Biceps Tendon: Footprint and Relevant Clinical Anatomy. George S. Athwal, MD, Scott P. Steinmann, MD, Damian M.

Posterolateral elbow dislocation with entrapment of the medial epicondyle in children: a case report Juan Rodríguez Martín* and Juan Pretell Mazzini

3.5 MM VA-LCP PROXIMAL TIBIA PLATE SYSTEM

Surgical Technique. Distal Humerus Locking Plate

Reverse Total Shoulder Replacement

BICEPTOR Tenodesis System

Radiographic Positioning for Dogs

Polarus 3 Solution Plates and Nails

Anatomical Shoulder Fracture. Surgical Technique

Shoulder Arthroplasty for Proximal Humerus Fracture

URSA HEMI-SHOULDER ARTHROPLASTY B I O T E K

Anterior-inferior Portal for Shoulder Arthroscopy at Anatomical Risk in Comparison Between the Inside-outand Outside-in Techniques

Surgical Technique. Clavicle Locking Plate

Gross Anatomy Questions That Should be Answerable After October 27, 2017

Arthroscopic biceps tenodesis is indicated for the

Shoulder Arthroscopy Lab Manual

region of the upper limb between the shoulder and the elbow Superiorly communicates with the axilla.

Immediate post surgical findings of soft tissue swelling, subcutaneous emphysema, and skin staples for reverse total shoulder arthroplasty.

Humerus shaft - Reduction & Fixation - Compression plate - AO Surgery Reference. Compression plating

Technique Guide. PHILOS and PHILOS Long. The anatomic fixation system for the proximal humerus.

Surgical Technique Guide PANTERA. Proximal Humerus Fracture Fixation Plate System

SHOULDER JOINT ANATOMY AND KINESIOLOGY

Tao Lin, Baojun Xiao, Xiucai Ma, Dehao Fu * and Shuhua Yang

Forearm Fracture Solutions. Product Overview

what you is back within LOVE arm s reach find out why the exactech shoulder may be right for you

MEDIAL EPICONDYLE FRACTURES

Adult Brachial Plexus Injuries: Introduction and the Role of Surgery

Orthopedics - Dr. Ahmad - Lecture 2 - Injuries of the Upper Limb

LOCKING TEP LOCKING TITANIUM ELASTIC PIN INTRAMEDULLARY NAIL

LCP Distal Humerus Plates

Hand Fracture System with Small Bone External Fixation System. Product Overview

humerus InSafeLOCK Nail

Proximal Humeral Fractures RSA v HHR. Proximal Humeral Fractures RSA v HHR. Introduction

Pre-Operative Planning. Positioning of the Patient

MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS FOR DISTAL RADIUS FRACTURES: SURGICAL TECHNIQUE M. TOBE 1, K. MIZUTANI 1, Y. TSUBUKU 1, Y.

PediLoc 3.5mm and 4.5mm Bowed Femur Plate Surgical Technique

Shoulder hemiarthroplasty in the management of humeral head fractures

Anatomical Study of Pectoral Nerves and its Implications in Surgery

Transcription:

doi: http://dx.doi.org/10.5704/moj.1811.001 Risk of Axillary Nerve Injury in Standard Anterolateral Approach of Shoulder: Cadaveric Study Kongcharoensombat W, MD, Wattananon P, MD Department of Orthopaedics, Lerdsin General Hospital, Bangkok, Thailand This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited Date of submission: 23rd December 2017 Date of acceptance: 13th August 2018 ABSTRACT Introduction: The anterolateral acromion approach of the shoulder is popular for minimally invasive plate osteosynthesis (MIPO) technique. However, there are literatures describing the specific risks of injury of the axillary nerve using this approach. Nevertheless, most of the studies were done with Caucasian cadavers. So, the purpose of this study was to evaluate the risk of iatrogenic axillary nerve injury from using the anterolateral shoulder approach and further investigate the location of the axillary nerve, associated with its location and arm length in the Asian population that have shorter arm length compared to the Caucasian population. Materials and Methods: Seventy-nine shoulders in fourtytwo embalmed cadavers were evaluated. The bony landmarks were drawn, and a vertical straight incision was made 5cm from tip of the acromion (anterolateral approach), to the bone. The iatrogenic nerve injury status and the distance between the anterolateral edge of the acromion to the axillary nerve was measured and recorded. Results: In ten of the seventy-nine shoulders, the axillary nerve were iatrogenically injured. The average anterior distance was 6.4cm and the average arm length was 30.2cm. The anterior distance and arm length ratio was 0.2. Conclusion: Our results demonstrated that the recommended safe zone at 5cm from tip of acromion was not suitable with Asian population due to shorter arm length, compared to Caucasian population. The location of axillary nerve could be predicted by 20% of the total arm-length. Key Words: axillary nerve, anterolateral shoulder approach, axillary nerve injury, cadaveric study INTRODUCTION The anterolateral acromion approach of the shoulder is a popular approach for the treatment of proximal humeral fractures, especially in minimally invasive plate osteosynthesis (MIPO) technique. The advantage of this approach is that it allows direct access to the lateral fracture planes for proximal humeral fracture reduction, plate placement and screw fixation 1-12 with potentially greater preservation of soft tissue structures than the deltopectoral approach 13. However, there are reports in the literature describing the specific risks of the axillary nerve injury in this approach 1-5, as, in the anatomical course of the axillary nerve, it wraps around the surgical neck of the humerus. Many studies have investigated and reported that it lies an average of 5cm distal to the acromion. Nevertheless, most of the studies had been done with Caucasian cadavers with one of the studies that reported about the significant correlation between arm length and position of axillary nerve 4. So, the purpose of this study was to evaluate the risk of iatrogenic axillary nerve injury from using the anterolateral shoulder approach and to further investigate the location of the axillary nerve, in relation to its anatomical location and arm length in the Asian population. MATERIALS AND METHODS Fourty-two embalmed cadavers were used in the study. Both shoulders were dissected in all, but 79 shoulders were included (five shoulders were too decayed and anatomy could not been identified). There was no previous history of trauma or surgery around the shoulder in the specimens. Corresponding Author: Wirat Kongcharoensombat, Department of Orthopaedics, Lerdsin General Hospital, 190 Silom Rd, 10500 Bangkok, Thailand Email: kwirat2003@yahoo.com 1

Table I: Demographic data Variables All patient (n=42) Age (mean) 76 (21-99) Gender Male 23 (54.8%) Female 19 (45.2%) Ethnicity Thai and Migrant Chinese Table II: Axillary nerve injury Code Sex Age Side Nerve Injury Nerve location Total arm length Nerve location / Yes/No (cm) (cm) total arm length 1 F 77 R No 7.1 29.3 0.2 2 F 77 L No 7.3 29.6 0.2 3 M 76 L No 7.5 30.2 0.2 4 M 76 R No 8.2 30.1 0.3 5 M 92 L No 6.5 30.2 0.2 6 M 92 R No 8.1 30 0.3 7 F 50 R No 4.9 29.2 0.2 8 F 50 L No 6.9 29.6 0.2 9 M 85 R No 7.5 34.1 0.2 10 M 85 L No 7 33.2 0.2 11 F 88 R No 6.6 29.1 0.2 12 F 88 L No 7.5 29.7 0.3 13 M 76 R No 6.6 29.2 0.2 14 M 76 L Yes 5 29.1 0.2 15 F 82 L Yes 4.9 26.6 0.2 16 F 82 R No 5.9 27.2 0.2 17 M 84 L No 6.5 30.1 0.2 18 M 84 R No 6.5 29.8 0.2 19 M 99 L No 6.7 31.2 0.2 20 M 99 R No 7.1 31.5 0.2 21 F 89 R Yes 4.6 27.2 0.2 22 F 89 L Yes 4.9 28.2 0.2 23 F 94 R No 5.5 28.2 0.2 24 F 94 L Yes 4.6 26.8 0.2 25 F 79 R No 5.3 26.5 0.2 26 F 79 L Yes 4.5 26 0.2 27 M 62 R No 7.2 32.2 0.2 28 M 62 L No 7 32 0.2 29 F 91 R No 6 27 0.2 30 F 91 L No 5.5 26.5 0.2 31 F 73 L No 7 29.2 0.2 32 F 73 R No 5.2 28.5 0.2 33 M 81 L No 8.1 34.2 0.2 34 M 81 R No 7.3 34.5 0.2 35 M 97 L No 7.5 32 0.2 36 M 97 R No 6.4 31.5 0.2 37 M 71 L No 8.2 33.2 0.2 38 M 71 R No 7.7 32.5 0.2 39 F 89 L No 5.5 29.3 0.2 40 F 89 R Yes 4.8 27.4 0.2 41 M 77 L No 6.5 31.1 0.2 42 M 77 R No 7.1 31.4 0.2 43 M 71 R No 5.5 30.8 0.2 44 M 71 L No 5.7 31.2 0.2 45 F 63 R Yes 4.9 30.2 0.2 46 F 63 L No 5.4 30.5 0.2 47 M 64 R No 7 29.5 0.2 48 M 64 L No 7.1 30.3 0.2 49 M 86 L No 6.3 32.2 0.2 50 M 86 R No 7.2 31.8 0.2 2

Risk of Axillary Nerve Injury Table II: Axillary nerve injury Code Sex Age Side Nerve Injury Nerve location Total arm length Nerve location / Yes/No (cm) (cm) total arm length 51 F 90 R Yes 4.6 29.5 0.2 52 F 90 L No 5.8 30.4 0.2 53 M 66 L No 6.7 31.5 0.2 54 M 66 R No 7.2 31 0.2 55 F 78 R No 5.9 29.5 0.2 56 M 92 L No 6 30.2 0.2 57 M 92 R No 6.5 31 0.2 58 F 68 L No 4.9 28 0.2 59 F 68 R No 6.1 28.5 0.2 60 F 73 L No 5.5 28.2 0.2 61 F 73 R No 6.4 28 0.2 62 M 84 L No 6.5 31 0.2 63 M 84 R No 6.6 30.5 0.2 64 M 71 L No 6.8 31.5 0.2 65 M 71 R No 7.4 31 0.2 66 F 75 R No 6.2 28.5 0.2 67 F 75 L No 6.5 28.8 0.2 68 M 77 L No 7.1 34.2 0.2 69 M 77 R No 8.1 33.5 0.2 70 F 68 R No 6.2 29.5 0.2 71 M 66 R No 7.6 29.5 0.3 72 M 66 L No 7.1 30.2 0.2 73 M 83 L No 7.2 31.8 0.2 74 M 83 R No 7.2 32 0.2 75 F 21 L No 5.6 30.5 0.2 76 M 76 L No 6.1 33.2 0.2 77 M 76 R No 6.1 33.4 0.2 78 M 54 R No 5.6 28.5 0.2 79 M 54 L No 5.6 29 0.2 M = 23 77.3 10/69 6.4 30.2 0.2 F = 19 (n=79) Total = 42 Fig. 1: Cadaver in supine position. Bony landmarks were marked. Incision was made for 5cm from tip of acromion. Fig. 2: Deltoid muscle reflected and the Axillary nerve identified. 3

With the cadavers in the supine position, the position of the acromion, clavicle and proximal humerus were marked. The distance between the anterolateral edge of the acromion to the lateral humeral condyle was measured and recorded as the arm length. The 5cm incision was made as a vertical straight line from the anterolateral edge of the acromion (anterolateral approach), deep to the bone, with the end of incision marked by silk (Fig. 1). Dissection was then performed and the deltoid muscle released from the acromion. The inner surface of the deltoid muscle was exposed, and the sub-deltoid fascia was excised to expose the axillary nerve (Fig. 2). Pins were inserted through the axillary nerve to outline its course on the outer surface of the deltoid muscle. Then, the deltoid muscle was sutured back to its original anatomic position. The iatrogenic nerve injury was identified (presence of sharp cut on the axillary nerve that occurred from the anterolateral approach incision) and the distance between the anterolateral edge of the acromion to the axillary nerve was measured and recorded. All the measurements were made using the Digital Vernier Caliper. The data were recorded using Microsoft Excel 2016 version. Data were shown as means ± SD. Statistical analysis was done using Graph Pad Prism version 7.02 software. Analysis between arm length and distance of axillary nerve from tip of acromion was performed using a Pearson's correlation coefficient. Values of p<0.05 were considered significant. RESULTS The mean age of all the persons (classified as cadavers in the study) at the time of death was 76 year (range: 21-99 years), and 54.8% were male. Most of them were Thai and immigrants from China (Table I). The axillary nerves were found to have been iatrogenically injured in 10 of 79 shoulders (12%). The means length between the axillary nerve and anterolateral edge of the acromion was 6.39±0.99cm (range: 4.6 to 8.2cm). The average arm length was 30.17±0.03cm (range: 26.1 to 34.5cm). There was a significant correlation between the arm length and the length between the axillary nerve and anterolateral edge of acromion, with an average index at 0.2 (95% CI: 0.205-0.217) (Table II). DISCUSSION The anatomy of the axillary nerve has been described by many authors. The distance from acromion varied from 3 to 9cm, depending on the reference point of acromion and shoulder positions. There are some muscles which have a supplementary function in elevation of the shoulder, such as rotator cuff muscle, pectoralis major muscle, etc. However, the anterior branch of axillary nerve is still important to preserve function of the shoulder. The anterior branch of the axillary nerve provides the motor function of deltoid muscle. The incidence of axillary nerve injury in deltoid splitting approach is about 7% but this in anterolateral approach is yet to be reported 1-7. With reference to the anterolateral approach of the shoulder, many textbooks state that the safe zone of axillary nerve is 5cm from tip of the acromion. However, cadaveric studies show that the distance of acromion to axillary nerve varies between from 4 to 8cm. So, the 5-cm-guideline does not guarantee absolute protection 8. In this study, we found that the nerve injury was 10 of 79 shoulders (12%). In terms of the location of axillary nerve, Cetik et al found that the average distance from anterior acromion was 6.1cm and the ratio between distance from anterior acromion and lateral epicondyle was 0.2. This is verified by the present study that the average was 6.3cm and the ratio was 0.2 4. However, we found that in 10 of 79 shoulders, the nerve locations were less than 5cm. From this fact, 5cm from the tip of acromion was to be considered not safe in all cases but the location of the nerve could be more safely estimated from 20% of arm length. This study demonstrated that the anterolateral surgical approach should be performed meticulously to identify and protect the axillary nerve. However, the axillary nerve might be at risk all the time, not only when stab incision is made but also in reduction of fracture or plate insertion. Gardner et al described the location of the nerve relative to the PHILOS plate. They found that the axillary nerve usually lay on the calcar screw hole 8. This information should help the surgeon to be aware of the risk when reducing, drilling and inserting the calcar screw. Several limitations exist in the current study. First, this is cadaveric study, so it may not reflect the same findings in patients. Second, though, we used the Digital Vernier Caliper for accuracy of measurement, human error could still occur. Third, it may not be possible to avoid the risk in patients who have displaced or comminuted fracture of proximal humerus resulting in injury-related deformity. CONCLUSION Our results demonstrated that the recommended safe zone at 5cm from the tip of acromion in anterolateral surgical approach of the shoulder was not suitable in the average Asian population due to shorter arm length, compared to the Caucasian population. The location of the axillary nerve could be more accurately be predicted by 20% of the total arm length. CONFLICT OF INTEREST The authors declare no conflicts of interest. 4

Risk of Axillary Nerve Injury REFERENCES 1. Apaydin N, Tubbs RS, Loukas M, Duparc F. Review of the surgical anatomy of the axillary nerve and the anatomic basis of its iatrogenic and traumatic injury. Surg Radiol Anat. 2010; 32(3): 193-201. doi: 10.1007/s00276-009-0594-8 2. Burkhead WZ, Scheinberg RR, Box G. Surgical anatomy of the axillary nerve. J Shoulder Elbow Surg. 1992; 1(1): 31-6. doi: 10.1016/S1058-2746(09)80014-1 3. Abbott LC, John B, Saunders M, Hagey H, Jones Jr EW. Surgical approaches to the shoulder joint. J Bone Joint Surg Am. 1949; 31(2): 235-55. 4. Cetik O, Uslu M, Acar HI, Comert A, Tekdemir I, Cift H. Is there a safe area for the axillary nerve in the deltoid muscle? A cadaveric study. J Bone Joint Surg Am. 2006; 88(11): 2395-9. 5. Vathana P, Chiarapattanakom P, Ratanalaka R, Vorasatit P. The relationship of the axillary nerve and the acromion. J Med Assoc Thai. 1998; 81(12): 953-7. 6. Wrete M. The sensory pathways from the shoulder joint. J Neurosurg. 1949; 6(5): 351-60. 7. Zlotolow DA, Catalano LW, Barron AO, Glickel SZ. Surgical exposures of the humerus. J Am Acad Orthop Surg. 2006; 14(13): 754-65. 8. Gardner MJ, Boraiah S, Helfet DL, Lorich DG. The anterolateral acromial approach for fractures of the proximal humerus. J Orthop Trauma. 2008; 22(2): 132-7. doi: 10.1097/BOT.0b013e3181589f8c 9. Perlmutter GS. Axillary nerve injury. Clin Orthop Relat Res. 1999; (368): 28-36. 10. Scully WF, Wilson DJ, Parada SA, Arrington ED. Iatrogenic nerve injuries in shoulder surgery. J Am Acad Orthop Surg. 2013; 21(12): 717-26. 11. Steinmann SP, Moran EA. Axillary nerve injury: diagnosis and treatment. J Am Acad Orthop Surg. 2001; 9(5): 328-35. 12. Zhang J, Moore AE, Stringer MD. Iatrogenic upper limb nerve injuries: a systematic review. ANZ J Surg. 2011; 81(4): 227-36. 13. Traver JL, Guzman MA, Cannada LK, Kaar SG. Is the axillary nerve at risk during a deltoid-splitting approach for proximal humerus fractures? J Orthop Trauma. 2016; 30(5): 240-4. 5