Analysis of e-liquid and e-cigarettes Vapoting test results

Similar documents
Applicant Name: GD Sigelei Electroinc Tech Co., Ltd B7 Building, No.1 District, Xicheng Science and Technology Park, Hengli Town, Dongguan, China

Multi Analyte Custom Grade Solution

CERTIFICATE OF ANALYSIS. tel: fax:

Bottom Ash Data Week 37

Bottom Ash Data Week 38

Bottom Ash Data Week 30

Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC

Bottom Ash Data Week 49

Bottom Ash Data Week 9

Bottom Ash Data Week 17

Test Report No.T JP Date: FEB 22, 2017 Page 1 of 6

Bottom Ash Data Week 12

Bottom Ash Data Week 8

USER SPECIFICATIONS FOR QUINTOLUBRIC 888 Series DESCRIPTION OF THE MOST IMPORTANT PROPERTIES AND THE POSSIBLE VARIATIONS AND TOLERANCES

Bottom Ash Data Week 1

Test Report No.T TC Date: JUN 29, 2018 Page 1 of 5

Test Report No.T JP Date: FEB 24, 2017 Page 1 of 6

Bottom Ash Data Week 40

Matrix Reference Materials - SCP SCIENCE

Edward V. Krizhanovsky, Ph.D., Kamila B. Tursunova

of human hair and nails. Part I. Analytical methodology, Sci. Tot. Environ. 2000, 250/1-3,

Test Report No.: T TY Date: DEC 19, 2018 Page 1 of 10

E-Cigarette Aerosol Analysis Report

Test Report No.: T TY Date: DEC 19, 2018 Page 1 of 12

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CARB 1004 Aldehyde/Ketone-DNPH Calibration

CERTIFICATE OF COMPLIANCE SGS United Kingdom A UKAS Accredited Test House

Trace Elements in Manure

Test Report No.: GZHL IP Date: Sep 01, 2016 Page 1 of 12

TEST REPORT Job No./Report No TR RV1 Date: 25 June 2015 Page 1 of 10

ENDS and Vaping. FCD Prevention Works Spring-Summer 2018

SAMPLE TEST Toxic Elements Analysis P P P Detection of Amines Derived From Azocolourants and Azodyes NA P P

TEST REPORT Job No./Report No TR Date:24 June 2015 Page 1 of 14

E-Cigarette Aerosol Analysis Report

Vapes, Ecigs, Mods, Juuls. Chris Harnish Mercer Island Youth & Family Services

Actual Excipient Test Data on Metal Impurities Submitted to IPEC-Americas from Industry

TRACE ELEMENTS IN URINE. Event #1, 2010

David S. Goya, DO, MBA, FCCP, FACP Kaiser Permanente Medical center Santa Clara, California

Chinese Zinc Sulfate Monohydrate testing. Dick Camp Kronos Micronutrients

Product Stewardship Information Sheet CH350LN

Mac-life-Plus. A Natural and Unique approach to support and boost your Immune System

A New Method for the Analysis of Carbonyl Compounds in e-cigarette Liquids

E-Cigarette Aerosol Analysis Report

Product Stewardship Information Sheet CH200LN-02

Study on assisted use of electronic cigarette (e-cig) concerning reduction of healthrelated harm associated with tobacco addiction

E-Cigarette Aerosol Analysis Report

Materials Declaration Form

E-Cigarette Aerosol Analysis Report

SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010

TEST REPORT. LAB LOCATION:TURKEY LAB NO. : (7216) SERVICE TYPE: Regular DATE IN: November 29 th, 2016 DATE OUT: December 01 th, 2016

Accredited Proficiency Testing Provider

TRACE ELEMENTS IN SERUM

COMPOST ANALYSIS REPORT

COMPOST ANALYSIS REPORT

Materials Declaration Form

NUTRIENT AND HEAVY METAL CONTENTS OF HOG MANURE - EFFECT ON SOIL QUALITY AND PRODUCTIVITY

Technical Report: (9617) SEPTEMBER 26, 2017 Date Received: SEPTEMBER 16, 2017 Page 1 of 10

Elemental analysis in clinical practice

AAFCO Check Sample 2015 Minerals Program. A Targeted and Engineered Concentration Program

Analysis of Milk for Major and Trace Elements by ICP-MS

E-Cigarette Aerosol Analysis Report

Test Report. No. SHATY Date: 21 Mar Page 1 of 6.

Analyses no.: Telephone: Fax: Telephone: Fax:

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

We are committed to becoming a watershed to Agriculture and restoring it to its rightful place in the economy. This is substantiated through our

TOXIC AND ESSENTIAL ELEMENTS

Routine Analysis of Fortified Foods using the Agilent 7800 ICP-MS

WAGENINGEN EVALUATING PROGRAMS FOR ANALYTICAL LABORATORIES. Certificate of Analysis. International Soil-Analytical Exchange REFERENCE MATERIAL

Example: Ammonium Sulphate (also called Sulphate of Ammonia) is composed of the following:

E-Cigarette Aerosol Analysis Report

Greg Patterson C.C.A. President A&L Canada Laboratories

E-Vapour (EVAP) Sub-Group 2017 Report. Kitzbühel, Austria October 10, 2017

Analyte Proficiency From All Labs # Analytes: 26 Sample # Statistical Summary # Labs Reporting: 82 Urea Issue Date : 06/30/2016

Figure 1. Location of 43 benchmark sites across Alberta.

Calibration Fee. Effective Date 15 July of 8

Supplying Nutrients to Crops

8 Micronutrients Overview & Dietary Reference Intakes (DRIs)

Validation of Isovaleraldehyde Using SKC UMEx 100 Diffusive Samplers (Cat. No )

CORESTA Recommended Method No. 74

METHOD DEVELOPMENT AND VALIDATION: QUANTIFICATION OF METALS IN LIQUIDS AND AEROSOL OF E-CIGARETTES

EDXRF APPLICATION NOTE

SICHERHEITSDATENBLATT

Mike Hinds, Royal Canadian Mint

PROVINCE OF BRITISH COLUMBIA ORDER OF THE LIEUTENANT GOVERNOR IN COUNCIL

A & L GREAT LAKES LABORATORIES, INC.

Wolf Creek Community Alliance 2009 Soil Sampling Report By BJ Schmitt January 26, 2010

Calibration Fee. Effective Date 15 Dec of 9

Chelated & Essentials. For Your Pet Animals

Landolt-Börnstein: Numerical Data and Functional Relationships in Science and Technology - New Series 12A. Ac-ag...Au-Zr. Bearbeitet von B Predel

Electronic Supporting Information

Compost Analysis. Sustainable Soil Management with the Mikhail Balance System

Challenges with Chelated &/or Complexed Minerals (Chelated and Soluble Methods of Analysis Used in FL)

!!"#$%&'!())*+,$-.&(.*/*+,)0&1-$2

Matrix Interferences in ICP-MS: Causes, Effects, and Strategies to Reduce or Eliminate Them

BIO-CHEMICALS FROM CONVERSION OF BIO-ETHANOL USING VARIOUS SINGLE OXIDES

Leaching Behavior of Coal Combustion Products and the Environmental Implication in Road Construction. Project Progress Report. Jianmin Wang NUTC R201

Transcription:

Report n 14/282 Analysis of e-liquid and e-cigarettes Vapoting test results Study for : INSMOKE Attention of : Mr MEILE Customer request nr : Agreement dated 29.04.14 Certech request nr: T277 Certech quotation nr : OP/14/322/TP Issue date : 30 May 2014 Scientific Approval, Quality Approval, CERTECH asbl - CEntre de Ressources TEchnologiques en CHimie Rue Jules Bordet, Zone Industrielle C B 7180 SENEFFE TVA BE 0470.677.454 ING 370-1128214-94 Tél : +32 (0)64 52 02 11 Fax : +32 (0)64 52 02 10 e-mail : info@certech.be

1. Introduction The purpose of this study, ordered by Mr Meile from Insmoke is to evaluate the nature and concentration of aldehydes/ketones and metals in the exhaust air of e-cigarettes. The methodology of this vapoting trial has been developed by Certech. The e-cigarettes have been received the 14/04/14, the e-liquid the 03/04/14. References of the samples are summarized in table 1. 2. Materials and methods 2.1 Materials and samples The samples were received the 03 and 14 April 2014. The references are presented in Table 1. Your reference Stardust (without nicotine) InSmoke Reevo Mini-S RB1632 InSmoke Shisha Apple Crush Table 1: Sample references Our reference 405E006 405E007 2.2 Methods The testing protocol is described in the figure 1 below. Schéma 1. Set-up of the vapoting test protocol In this set-up, the electonic cigarette (cartridge full of e-liquid) is connected to a 3-ways valve. The connection between the e-cigarette and the valve is made of silicone (< 1cm). The valve is made of stainless steel and Téflon and is connected to a timer programmed to generate a 3-seconds-puff every 30 seconds. CERTECH asbl page 2 of 7 14/282

The aerosol generated is trapped in a first bubbler placed in an ice bath. The connection between the valve and the first bubbler is made of Téflon (<1cm). The bubbling solution is selected in function of the compounds to analyse. A second bubbler is also connected to ensure the trapping of the compounds which would not have been trapped in the first one. At the outlet of the second bubbler, a pump is connected, set at an airflow rate of around 1000mL/min (measured precisely by a bubble flowmeter). Practically, a constant airflow is applied by the pump. The valve combined with the timer ensures an air intake through the e-cigarette only during 3 sec., pure air being drawn during the following 30 seconds. The air of the laboratory is controlled by a conditioning air unit, allowing the generation of pure air by mean of activated carbon filter, regulated in terms of temperature and humidity. The air flow rate in the laboratory is very high to reach an important air exchange rate. Finally, a blank analysis is performed with the same set-up but without any e-cigarette to evaluate the background concentrations. 2.3 Aldehydes/ketones analysis in the exhaust air The bubbling has been performed in a solution containing a derivatisation agent, the DNPH (dinitrophénylhydrazine) in order to form stable derivatives. The analysis * has been realised by HPLC-UV with external calibration. * Standard list: Formaldehyde, acetaldehyde, acetone, acroleine, propionaldehyde, crotonaldehyde, butyraldehyde, benzaldehyde, isovaleraldehyde, valeraldehyde, o-tolualdehyde, m+p-tolualdehyde, hexaldéhyde +2,5-dimethylbenzaldéhyde. 2.4 Metals analysis The bubbling has been performed in an acid solution (miliq water acidified with 1% nitric acid at 65%). The analysis ** has been realised by ICP-MS in a partner lab certified ISO 17025 for this measurement. ** Standard list : Calcium (Ca), Magnesium (Mg), Natrium (Na), Potassium (K), Bore (B), Aluminium (Al), Vanadium (V), Chrome (Cr), Iron (Fe), Cobalt (Co), Manganèse (Mn), Nickel (Ni), Cuivre (Cu), Zinc (Zn), Arsenic (As), Silicium (Si), Sélénium (Se), Strontium (Sr) (1), Molybdène (Mo), Argent (Ag) (1), Etain (Sn), Cadmium (Cd), Antimoine (Sb), Barium (Ba), Plomb (Pb), Uranium (U) (1), Beryllium (Be) (1), Mercure (Hg), Phosphore total (PO4tot). (1) compounds out of the scope of the ISO 17025 accreditation of the partner laboratory. CERTECH asbl page 3 of 7 14/282

3. Results 3.1 Aldehydes/ketones The table 2 hereafter presents the parameters of the tests: - Columns 1 and 2 mention the references of the samples - Column 3 indicates the day of the test - Column 4 is for the consumption of e-liquid during the test. It has been calculating by weighing the sample before and after the test - Column 5 indicates the volume of each puff. This volume is calculated from the air intake rate measured during the test and the length of the puff (3 seconds) - Column 6 mentions the duration of the whole test (in min.) - Column 7 mentions the total amount of puffs, calculated from the duration of the test and the test conditions (one 3-seconds-puff every 30 seconds). Table 2. Experimental parameters for the quantification of carbonyle compounds in the exhaust air Samples references InSmoke Reevo Mini-S + e-liquid stardust 405E006 + Date of the test Amount of e- liquid used (g) Volume per puff (ml) Duration of the test (min) Amount of puffs 14/05/2014 0,15 50 55 100 RB1632 InSmoke Shisha Apple Crush 405E007 14/05/2014 0,22 50 55 100 Blank aldehydes / 14/05/2014 NA 50 55 100 Table 3 presents the results obtained after analysis of the bubblers by HPLC-UV according to the list of compounds mentioned in point 2 of the report. Results are expressed in µg/100 puffs. Table 3. Results of aldehydes/ketones analysis in the aerosol (in µg for 100 puffs) Results expressed in µg for 100 puffs e-cigarette Liquid Blank InSmoke Reevo Mini-S 405E006 Stardust RB1632 InSmoke Shisha Apple Crush 405E007 Number of puffs 100 100 100 formaldehyde <0,7 2,3 18,5 acetaldehyde ND 1,5 3,4 acetone <0,7 <0,7 8,3 acrolein ND 10,6 6,2 propionaldehyde 2 2,2 13,5 crotonaldehyde ND ND 16 butyraldehyde ND ND ND benzaldehyde ND ND 26,1 - CERTECH asbl page 4 of 7 14/282

isovaleraldehyde ND ND ND valeraldehyde ND ND ND o-tolualdehyde ND ND 3,2 m+p-tolualdehyde ND ND ND hexaldehyde + 2,5-dimethylbenzaldehyde <0,7 1,5 1,5 Detection limit 0,2 0,2 0,2 Values obtained for the blank test are reported in the table and not subtracted to the sample results. 3.2 Metals The table 4 hereafter presents the parameters of the tests: - Columns 1 and 2 mention the references of the samples - Column 3 indicates the day of the test - Column 4 is for the consumption of e-liquid during the test. It has been calculating by weighing the sample before and after the test - Column 5 indicates the volume of each puff. This volume is calculated from the air intake rate measured during the test and the length of the puff (3 seconds) - Column 6 mentions the duration of the whole test (in min.) - Column 7 mentions the total amount of puffs, calculated from the duration of the test and the test conditions (one 3-seconds puff every 30 seconds). Table 4. Experimental parameters for the quantification of metals in the exhaust air Samples references InSmoke Reevo Mini-S + e-liquid stardust 405E006 + Date of the test Amount of e- liquid used (g) Volume per puff (ml) Duration of the test (min) Amount of puffs 13/05/2014 0,18 50 55 100 RB1632 InSmoke Shisha Apple Crush 405E007 13/05/2014 0,28 50 55 100 Blank aldehydes / 13/05/2014 NA 50 55 100 The table 5 presents the results obtained after analysis of the bubblers by ICP-MS according to the list of compounds listed in point 2. Results are expressed in µg for 100 puffs. Values obtained for the blank test are reported in the table and not subtracted to the sample results. CERTECH asbl page 5 of 7 14/282

Tableau 5. Results obtained for the metals analysis (in µg for 100 puffs) BLANK InSmoke Reevo Mini- S 405E006 Stardust RB1632 InSmoke Shisha Apple Crush 405E007 Number of puffs 100 100 100 Air intake through the e-cigarette (L) 5 5 5 E-liquid consumption (g) / 0,18 0,28 Quantity in µg / 100 puffs Mercure Hg µg ND (<0,005) ND (<0,005) ND (<0,005) Uranium U µg ND (<0,003) ND (<0,003) ND (<0,003) Calcicum Ca µg ND (<200) ND (<200) ND (<200) Magnésium Mg µg ND (<10) ND (<10) 20 Sodium Na µg 30 ND (<20) ND (<20) Potassium K µg ND (<25) ND (<25) ND (<25) Silice Si µg ND (<10) 10 20 Aluminium Al µg 1,8 1,7 1,8 Bore B µg 0,5 1,5 0,6 Fer Fe µg 2,4 2,4 2,8 Manganèse Mn µg 0,3 0,2 0,4 Cuivre Cu µg 0,3 0,2 0,3 Zinc Zn µg 24,4 9,2 30,8 Etain Sn µg 0,3 0,2 0,2 Cobalt Co µg ND (<0,1) ND (<0,1) ND (<0,1) Baryum Ba µg 1,3 1,2 1,3 Argent Ag µg ND (<0,05) ND (<0,05) ND (<0,05) Arsenic As µg <0,1 <0,1 <0,1 Berylium Be µg ND (<0,01) ND (<0,01) ND (<0,01) Cadmium Cd µg ND (<0,005) <0,1 ND (<0,005) Chrome Cr µg ND (<0,05) ND (<0,05) ND (<0,05) Nickel Ni µg 0,1 0,1 0,1 Plomb Pb µg 0,5 0,3 0,6 Antimoine Sb µg <0,1 <0,1 0,1 Selenium Se µg ND (<0,03) ND (<0,03) ND (<0,03) Vanadium V µg ND (<0,03) ND (<0,03) ND (<0,03) Strontium Sr µg ND (<0,3) ND (<0,3) ND (<0,3) Molybdène Mo µg 0,1 <0,1 0,1 Phosphate totaux PO4 µg ND (<10) ND (<10) ND (<10) - CERTECH asbl page 6 of 7 14/282

Annexe A. Conditions analytiques Conditions analytiques pour les analyses par GC-MS GC-MS ANA 23.03 GC : HP 6890 MS : HP 5973 Colonne : Zebron ZB-WAX (60m x 0,25mm x 0,5µm) Gaz vecteur: He 6.0 Conditions analytiques pour les analyses par HPLC-UV HPLC: Waters Alliance 2690 Colonne : Waters Symmetry C18 Détecteur : Waters PDA 996, λ= 360 nm CERTECH asbl page 7 of 7 14/282