Dilip D Tanna, Sangeet Gawhale, Kaustubh Shinde, Viral Gondalia, 3 4. Hayoung Park, Ashok Shyam

Similar documents
The study of distal ¼ diaphyseal extra articular fractures of humerus treated with antegrade intramedullary interlocking nailing

Fibula bone grafting in infected gap non union: A prospective case series

Orthopedics in Motion Tristan Hartzell, MD January 27, 2016

CASE REPORT. Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report

7/23/2018 DESCRIBING THE FRACTURE. Pattern Open vs closed Location BASIC PRINCIPLES OF FRACTURE MANAGEMENT. Anjan R. Shah MD July 21, 2018.

Minimally Invasive Plating of Fractures:

Treatment Approach To Cases Of Nonunion Intercondylar Fracture Humerus

Results of tibia nailing with Angular Stable Locking Screws (ASLS); A retrospective study of 107 patients with distal tibia fracture.

Open reduction and internal fixation of humeral non-unions : Radiological and functional results

Surgical Management of aseptic Femoral Shaft Non-union after Intramedullary Fixation

HUMERAL SHAFT FRACTURES: ORIF, IMN, NONOP What to do?

CASE REPORT. Bone transport utilizing the PRECICE Intramedullary Nail for an infected nonunion in the distal femur

Fractures of the tibia shaft treated with locked intramedullary nail Retrospective clinical and radiographic assesment

Posteromedial approach to the distal humerus for fracture fixation

BRIDGE PLATING OF COMMINUTED SHAFT OF FEMUR FRACTURES

Elbow Fractures ORIF VS Arthroplasty

International Journal of Health Sciences and Research ISSN:

Distal femoral fracture with subsequent ipsilateral proximal femoral fracture

Techique. Results. Discussion. Materials & Methods. Vol. 2 - Year 1 - December 2005

EVOS MINI with IM Nailing

Diaphyseal Humerus Fractures. OTA Course Dallas, TX 1/20/17 Ellen Fitzpatrick MD

The long term fate of the fibula when used as an intraosseous graft

3.5 mm LCP Distal Tibia T-Plates

OUTCOME OF MANAGEMENT OF CLOSED PROXIMAL TIBIA FRACTURES IN TERTIARY HOSPITAL OF SURAT Karan Mehta 1, Prashanth G 2, Shiblee Siddiqui 3

Zimmer Small Fragment Universal Locking System. Surgical Technique

97% UNION. Humeral Nonunions: Issues and Strategies? Disclosure. Humeral Shaft Fractures 5/3/2016. Cory Collinge, MD

Conventus CAGE PH Surgical Techniques

ICUC Paper. Variable Angle Locked Screw (VAL): from concept to application. A. Fernández Dell'Oca, P. Regazzoni, S.M. Perren.

Locked plating constructs are creating a challenge for surgeons.

A Clinical Study For Evaluation Of Results Of Closed Interlocking Nailing Of Fractures Of The Shaft Of The Tibia

Case Report. Antegrade Femur Lengthening with the PRECICE Limb Lengthening Technology

LISS DF and LISS PLT. Less Invasive Stabilization Systems for Distal Femur and Proximal Lateral Tibia.

Of approximately 2 million long bone fractures

CASE REPORT. Antegrade tibia lengthening with the PRECICE Limb Lengthening technology

Neurologic Damage. The most common neurologic injury following intramedullary tibial nailing is injury to the peroneal nerve.

Nonunion of the Femur Treated with Conventional Osteosynthesis Combined with Autogenous and Strut Allogeneic Bone Grafts

Comparative Study between Locking Compression Plate vs. Supracondylar Nail for Supracondylar Femur Fractures

LCP Extra-articular Distal Humerus Plate.

LOCKING TEP LOCKING TITANIUM ELASTIC PIN INTRAMEDULLARY NAIL

Distal Humerus Fractures: How should they be fixed?

Treatment of delayed union or non-union of the tibial shaft with partial fibulectomy and an Ilizarov frame

Humerus shaft - Reduction & Fixation - Compression plate - AO Surgery Reference. Compression plating

Types of Plates 1. New Dynamic Compression Plate: Diaphyseal fracture: Radius, Ulna, Humerus, Rarely tibia

THE HUMERUS 20 THE HUMERUS* CROSS SECTION CROSS SECTION SUPERIOR VIEW

Surgical treatment of aseptic nonunion in long bones: review of 193 cases

TIPMED EXTERNAL FIXATION SYSTEMS

Tibial Shaft Fractures

Technique Guide. 3.5 mm LCP Periarticular Proximal Humerus Plate. Part of the Synthes locking compression plate (LCP) system.

Knee spanning solutions

Nearly all of these fractures are displaced, given the paucity of soft tissue attachments.

Crossed Steinmann Pin Fixation In Supracondylar Femur Fractures In Adults A Case Series

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Orthopedic Bone Nail System - Distal Femoral Nail Surgical Technique Manual

Minimally Invasive Plate Osteosynthesis (MIPO) for Proximal and Distal Fractures of The Tibia: A Biological Approach

Vasu Pai FRACS, MCh, MS, Nat Board Ortho Surgeon Gisborne

3.5 mm LCP Extra-articular Distal Humerus Plate

Study on the Functional Outcome of Internal Fixation in Tibial Plateau Fractures

ILIZAROV TECHNIQUE IN CORRECTING LIMBS DEFORMITIES: PRELIMINARY RESULTS

Osteosynthesis involving a joint Thomas P Rüedi

Management of Fractures. Traumatology RHS 231 Dr. Einas Al-Eisa Lecture 5

Increasing surgical freedom Restoring patient function

E ORIGINAL ARTICLE Low extra-articular (transcondylar) fractures of the distal humerus

Distal Femur Fractures in The Elderly The Ideal Construct

Technique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

LCP Distal Humerus Plates

Tibial deformity correction by Ilizarov method

Bone transport for the management of severely comminuted fractures without bone loss

.org. Tibia (Shinbone) Shaft Fractures. Anatomy. Types of Tibial Shaft Fractures

LCP Anterior Ankle Arthrodesis Plates. Part of the Synthes Locking Compression Plate (LCP) System.

GAMMA LOCKING NAIL INSTRUMENTS OPERATIVE TECHNIQUE

Calcium Phosphate Cement

Non-Anatomical Surgical Solutions for Difficult Non-Unions: Case Series

Principles of intramedullary nailing. Management for ORP

Locked Plating: Clinical Indications

LCP Distal Tibia Plate

CiSE. PHILOS Plate Osteosynthesis in Metaphyseal Fractures of the Distal Humerus through an Anterolateral Approach. Introduction ORIGINAL ARTICLE

Open reduction; plate fixation 1 Principles

Surgical Technique. Targeter Systems Overview

Surgical Care at the District Hospital. EMERGENCY & ESSENTIAL SURGICAL CARE

Study of Ender s Nailing in Paediatric Tibial Shaft Fractures

Bipolar Radial Head System

AO / Synthes Proximal Posterior Medial Tibia Plate. Tibial Plateau Fx. Osteosynthesis

Infected forearm nonunion treated by bone transport after debridement

Lengthening & Deformity correction with. Fixator Assisted Nailing

Surgical interventions in chronic osteomyelitis

Closed reduction and internal fixation of fractures of the shaft of the femur by the Titanium Elastic Nailing System in children.

Technique Guide. 3.5 mm LCP Proximal Tibia Plate. Part of the Synthes Small Fragment LCP System.

ORIGINAL ARTICLE. INTER TROCHANTERIC # NECK FEMUR FIXATION WITH TFN 250 CASES. Prasad Vijaykumar Joshi, Chandrashekar Yadav.

Surgical Technique. Distal Humerus Locking Plate

Surgical Technique Guide PANTERA. Proximal Humerus Fracture Fixation Plate System

Technique Guide. LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.

TheUseofaFreeFibularStrutasa Biological Intramedullary Nail for the Treatment of Complex Nonunion of Long Bones

Patient Guide. Intramedullary Skeletal Kinetic Distractor For Tibial and Femoral Lengthening

Technique Guide. PHILOS and PHILOS Long. The anatomic fixation system for the proximal humerus.

Surgery-Ortho. Fractures of the tibia and fibula. Management. Treatment of low energy fractures. Fifth stage. Lec-6 د.

JMSCR Vol. 03 Issue 08 Page August 2015

A study of MIPO by locking compression plate fixation in the management of distal tibial metaphyseal fractures

Transcription:

Original Article Trauma International 2017 Jan- April;3(1) :27-31 Intramedullary Fibula with Rigid Osteosynthesis in Revision of Neglected and Multiple times Operated Non Union of Long Bones Abstract 1 1 2 1 Dilip D Tanna, Sangeet Gawhale, Kaustubh Shinde, Viral Gondalia, 3 4 Hayoung Park, Ashok Shyam Background: Plates with Intramedullary Fibula as Strut graft(ifsg) in Non- union of long bone fractures provides most stable construct overall as fibula acts as second implant, screws have better anchorage and very high pull out strength due to penetration of four cortices and osteogenic property of the fibula is most helpful. The aim of this paper is to re-focus the importance of non-vascularised intramedullary fibula as a second internal biologic stable splint along with rigid osteosynthesis for the treatment of difficult and neglected non -union of long bones. Methods and Material: 15 cases (13 :2,males: females) of revision surgery for the neglected and multiply operated non-union of the long bones were treated with the debridement, decortication and shingling of the fracture site with addition of the trimmed fibula (as intramedullary strut). Liberal cancellous bone graft was added subperiosteally with stable and rigid internal osteosynthesis by using LCP. DASH Score was used for upper limb and VAS for lower limb for assessment. Results: Union was achieved in all patients in 12 months (range 9-12 months). Preoperative DASH score averaged 40.86(range 42.6-52.6). DASH score at the last follow-up averaged 20.38 points (range 16.4-24.2).difference was significant. (p=0.0001) Conclusions: Intra medullary fibula almost works mimicking double plate and adds in the stability as it works as second plate. Its osteogenic property helps in the healing, not only at the fracture site but proximal and distal to it. This prevents slow union at the ends of bone which are usually avascular because of the lysis. Screws have a better hold around osteoporotic bones due to four cortices hold in presence of fibula. Strong bony union can be successfully achieved in almost all cases with rigid compression at the fracture site & additional extensive cancellous bone grafting. Key-words: Intra- medullary Fibula,revision non union, rigid osteosynthesis Introduction Non -union, of multiple times operated long bone fractures, poses the extreme challenge to the orthopaedic surgeons. Surgical treatment of proximal humeral non unions and malunions are technically challenging. Osteosynthesis with bone grafting for the treatment of nonunions is indicated in young, active patients with adequate bone stock in the proximal fragment and preservation of the glenohumeral articular surfaces[2] Vascularised bone grafting requires surgical experience and equipment not readily available in every hospital. The technique is demanding of time and resources, and vascular thrombosis may compromise the result [5] Iliac crest cancellous bone graft has no mechanical strength to withstand stresses prior to solid union of the fracture site and also is associated with quite significant graft harvest site morbidity. The fibula transmits one eighth of body weight and can be as useful as vascularised or non-vascularised graft in reconstruction of bony defects. Compression plating with autogenous grafting is accepted as the gold standard method so has yielded satisfac tory results, with 92 to 100% healing rates Operative treatment can be very successful when the techniques of plate-and-screw fixation are modified to address osteopenia and relative or absolute loss of bone. Healing of the fracture substantially improves function and the degree of independence[6] Subjects and Methods: 15 patients of multiply operated non union of long bones (13 humerus, 1 femur and one distal tibia non union) 1 Saifee Hospital Medical research center, Mumbai, India. 2 BY L Nair medical college & hospital, Mumbai 3 Researcher Department of Orthopaedics Joint Arthritis & research Laboratory Himchan Hospital Seoul,South Korea 4 Indian Orthopaedic Research Group, Thane & Sancheti Institute of Orthopaedics and Rehabilitation, Pune, India. Address of Correspondence Dr D D Tanna 3A new queens road back bay view, mama parmanand marg. Mumbai 400004 Email: ddtanna@me.com Dr. Dileep Tanna Dr. Sangeet Gawhale Dr. Viral H Gondalia Dr. Ashok Shyam Copyright: the author(s), publisher and licensee Indian Orthopaedic Research Group Available on doi: 10.13107/trauma.2455-538X.2017.019 (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. 27 Trauma International Volume 3 Issue 1 Jan-June 2017 Page 27-31

Figure 1: 52 years old male, who was operated 4 times within last 10 years & presented to us with this latest x rays showing atrophic gap non union of the proximal humerus were included in a study. All were treated by open reduction of the fracture, debridement and excision of the fibrosis, shingling of the bone both proximally and distal to fracture site and osteosynthesis with strut non vascularised fibular graft and Locking Compression Plate with few locking screws and rest of all are cortical screws to make it rigid and stable construct with extensive cancelleous bone grafting 360⁰ surrounding the fracture site. All patients were assessed at final follow up using D.A.S.H score for upper limb and Visual analogue score for lower limb. All patients were followed up for 4 to 36 (average mean months is 20 months) except two patient, who are under study with last two-two and half months. Out of 15 patients,13 were male and 2 were female. Out of 15, 13 patients had humerus non union,two had femoral mid shaft non union and remaining one had lower third distal tibia non union. Out of the 13 humerus cases 4 had proximal humerus, 7 had mid shaft to lower third humerus(m3-l3rd) non union & two patient has non union of segmental shaft humerus fracture. a Figure 2: Humeral Medullary canal is prepared using reamers to achieve uniform medullary cavity All were closed fractures except one open fracture and all had eventual atrophic non-union upon presentation. The patients had mild pain, tenderness and abnormal mobility at the non-union site (except distal tibia and middle femur), and limitation of activities of daily living. All patients had stiff ness of shoulder and elbow to varying degrees. The patients with femoral non unions have constant pain at the fracture site and difficulty while bearing weight. distal tibia non union patient had not started bearing weight as he was on fixator for three months following the Gun shot injury operated in other country. Surgical technique: 52 years old male, who was operated 4 times within last 10 years, presented to us with this latest x rays showing atrophic gap non union of the proximal humerus (Fig 1 A,1B) Fracture site was exposed using previous scar in all cases as to avoid cosmetic ugly scar. The fibrous non-union and any devitalised bone b a b c Figure 3: Splitting the Fibula graft using an oscillating saw d e Figure 4: Method of insertion of Intramedullary fibula into Non United Bone Proximally & Distally :Distraction at fracture site to accommodate the graft (a) and C arm picture of the same (b). Method of compression at the fracture site with fibula in situ ( c). with C arm confirmation of compression (d). plate fixation Proximally & distally with fibular Intramedullary graft plus massive cancelleous autografts (e). 28 Trauma International Volume 3 Issue 1 Jan-June 2017 Page 27-31

a b c d Figure 5: Two month follow up radiograph shows good alignment and union (a-b) with good clinical function (c-d) were thoroughly excised and the medullary canal opened via sharp thinner humerus awl and 3.5-4.5 mm drill bits. Preparation of the medullary canal: The humeral medullary canal was prepared to accept the bone graft. Fibrous and pseu doarthrosis tissue were removed completely and the medullary cavity reconstituted both proximally and distally by curettage, drill or the use of serial hand reamers (6mm-9mm). Dilate humerus medullary cavity mainly to measure the cavity Uniformly expanded medullary cavity by the reamers was prepared to put in the graft.(fig 2a,2b) Preparation of fibular graft: The mid-shaft of the fibula was then harvested under tourniquet control with care taken to identify and protect the superficial peroneal nerve. The fibular shaft of excess length was harvested so that it could be trimmed as neces sary. The fibula graft was trimmed so as to enable it to telescope snugly into the fragments across the fracture site. Size of fibula graft will be one smaller than Last reamer used. If the thickness did not permit its use, it was conversely bevelled at one of the ends leaving behind proximal wider part in hollow cavity of proximal humerus and remaining part in the distal shaft. Generally in humerus,it necessary to split fibula in the center, with oscillating saw or reciprocating saw or large bone cutter instruments to reduce the size (Fig 3) 5. Insertion of the fibular graft: The fibular autograft was pushed into one of the fracture fragments and the exact length of graft that needed trimming was assessed. Once the final shaping of the graft was done, the fracture was reduced with the intramedullary fibular graft spanning the fracture site. Confirm it is movable in the humerus medullary cavity on both sides of fracture easily. Plate fixation: Reconfirm graft moving in canal push it up all the way proximally(fig 4 - a,b) Reduce fracture, distract slightly hold fibula end and slowly push it distally(fig 4c Compress fracture maximally and add cancellous graft after shingling (Fig 4 c & 4 d) How to achieve compression at the fracture with intramedullary graft: It is safer to do compression by Muller s device as it is applied at the end of the bone and maximum compression can be achieved by this device. If one chooses to compress by D C P holes. Fix screw on one side of fracture, and for opposite side D C P hole should be used which is not going thru the fibula, as if fibula is fixed it will not allow compression. So under C arm see the end of fibula and go beyond it to put other D C P screw and compress. Generally one hole compression is not enough in this non union set up, so it will have to be repeated also on 2nd hole. so it is suggested to use Muller s device or a webers device to do compression of the fracture. a b c d e f Figure 6: Case 2 - Pre op image of the atrophic gap non union of the humeral shaft AP and Lateral views (a,b). Intra op image showing wide gap & atrophic bony ends ( c). Harvested Autograft(Intramedullary fibula) (d). Intra operative pictures with LCP & fibula in situ (e). Final Radiograph of the patient (f). Additional BMP protein was used in this patient 29 Trauma International Volume 3 Issue 1 Jan-June 2017 Page 27-31

Preoperative DASH score averaged 40.86(range 42.6-52.6). DASH score at the last follow-up averaged 20.38 points (range 16.4-24.2).(p=0.0001)[Table 1] V.A.S (visual analogue scale) in one patient was improved from 6-7 to 2 at the last follow up.[table 1] There was an average loss of 10-20 abduction and 15-20 flexion of the shoulder.. Range of motion of adjacent joint (knee in lower limb and elbow in upper limb) was restricted in all patients because of history of multiple surgeries and immobilization periods, but was within the functional limit in all except two patients. There was no change in shoulder rotations following surgery on the contrary three patient had pain free rotation of shoulder who had atrophic proximal humerus non union. One patient with preoperative fixed flexion deformity of elbow to varying degrees had persistence of a similar deformity at the last follow-up. Table 1: Table showing preoperative and post operative DASH Scores in all patients A LCP was used with quadricortical screw fixation till fibula is extending. Each screw hole was drilled and tapped through four cortices, two in the fractured bone and two in the intact fib ula and 4. 5 mm cortical screws were inserted. End of the bone screws were from parent bone and few locking screws were used for osteoporosis. Shoulder and elbow exercises were started a day after the opera tion. Lifting of weights using the operated limb was deferred for a period of three to four months or until osteo-integration of the fibular ends or fracture healing. After hospital discharge, patients were observed on a monthly basis until healing of the fracture. All pa tients were examined both clinically and radiologically. Fracture union was considered radiographically if callus formation was seen in three of four cortices on AP and lateral views. Clinical union was considered when the fracture site was painless. Data collected retrospectively included grip strength, range of motion, radiographic parameters, and functional outcomes as measured by the DASH (Disabilities of the Arm, Shoulder and Hand) questionnaire. Results Patients were followed-up for an average of 1.5-2 years (range 1-2 years). Union was achieved in all patients in 12 months (range9-12 months ) and patients were very satisfied with the treatment Figure 5 shows long term follow up of case 1 and figure 6 shows the results in case 2. There were no perioperative complications such as wound infection, radial nerve palsy, hematoma formation. Post op two patient had discomfort over the fibular graft harvest site, and one has ASIS graft site morbidity in the form of pain mainly. One patient has persistent fracture line visible on fresh x ray at the shaft of humerus at one year follow up, but still fracture seems to be clinically united as patient has painless arm movement. Discussion Non -union of the long bone, after repeated surgery with multiple failed attempts poses challenging reoperation. Healing is challenge & unpredicted with any kind of surgery and may have sub-optimal result. We have done 15 cases of previously operated multiple times with failed union As we have used massive mixed cortico-cancelleous auto graft in almost all cases circumferentially at the non-union site the reason why it unites in each cases is not definite what worked out of these procedure is not predictable, like shingling & solid compression at the fracture site+cancelleous autograft Vs IMSF autograft. Before we conclude, that fracture is united, we need evidence of circumferential callus formation, and osteo-integration, which takes long time, to be observed. Though patient is using arm almost normally, probably due to good long bony rigid fixation, and hence clinical signs of union are not convincing. This is observed most often in such multiple times operated cases only after 12 months and so we feel, 12 months minimum time should be considered for union. The main weakness of our study is 1. Very few number of cases(only 15 cases)-so difficult to judge trend of results 2. What exactly helped union, out of everything we did is unclear The main strength of our study: Our procedure can not only salvage the function less atrophic non united bone ----it can even have profound effect on the overall compliance of the patient, reduce repeated morbidity from the lengthy and costly treatment like ilizarov, which has frustrated outcome and at the same time gives pain free extremity function up to its fully maximum ability. We did not seen any complication like post op infection, radial nerve palsy, implant cut through, not even fracture of the fibula graft in any case. Two patient had fibula graft site pain, which subsided within 6 months and another female patient had ASIS graft site pain mainly which also settled within a year. The reason for low complications in all cases may be we were lucky. Osteoporosis, either as a result of disuse or due to generalised metabolic causes, compounds the choice of surgical treatment in these patients. It significantly reduces the pull out strength of the screws thus increasing the chance of implant failure. Humeral nonunion in osteoporotic bone presents a reconstructive challenge for the treating orthopaedic 30 Trauma International Volume 3 Issue 1 Jan-June 2017 Page 27-31

surgeon [3,4]. In case of non-union, mechanical stability at the fracture site and biologic re vitalization are keys for the management. A non-union of a diaphyseal fracture of the humerus can present a major functional problem even in the elderly population. Advances in operative exposures combined with newer techniques of achieving stable internal fixation even in the presence of pathologic bone have enabled the surgeon to successfully treat even the most complex non unions [7] Approximately 10% of all long-bone fractures occur in the humerus. Although primary treatment usually is successful, humeral nonunion can lead to marked morbidity and functional limitation. Complications include joint contractures of the shoulder and elbow, especially with periarticular pseudarthrosis. Marked osteopenia or bone loss, or both, often occur after fracture and after failure to achieve union. Retained implants often break, impeding fixation and requiring removal. Soft-tissue deficits and incisions from the original injury or prior surgeries also may complicate reconstruction, as can intra-articular fractures and associated nerve palsies. Successful surgical management of humeral nonunion requires stable internal fixation that allows early joint motion and uses autogenous bone graft to promote healing [8,9] DCP with cancellous bone graft is a reliable and an effective treatment for revision of aseptic nonunion of humeral shaft fracture after surgical treatment [10,11] We have used LCP in all 15 cases. References 1. Volgas DA, Stannard JP, Alonso JE. Nonunions of the humerus. Clin Orthop Relat Res. 2004 Feb;(419):46-50. 2. Cheung EV, Sperling JW. Management of proximal humeral nonunions and malunions. Orthop Clin North Am. 2008 Oct;39(4):475-82. 3. Ansell RH, Scales JT. A study of some factors which affect the strength of screws and their insertions and holding power in bone. J Biomechanics 1968;1:279 302 4. Schatzker J, Sanderson R, Murnaghan JP. The holding power of orthopaedic screws in vivo. Clin Orthop 1975;108:115 26 5. Jupiter JB. Complex non-union of the humeral diaphysis: treatment with a medial approach, an anterior plate, and a vascularized fibular graft. J Bone Joint Surg Am. 1990 Jun;72(5):701-7. 6. Ring D, Perey BH, Jupiter JB. The functional outcome of operative treatment of ununited fractures of the humeral diaphysis in older patients. J Bone Joint Surg Am 1999; 81: 177-90. 7. Jupiter JB, Von Deck M. Ununited humeral diaphyses. J Shoulder Elbow Surg 1998; 7: 644-53. 8. Pugh DMW, McKee MD. Advances in the management of humeral non-union. J Am Acad Orthop Surg 2003; 1: 48-59. There are four main indications reported in the literature for use of LCP in fractures:1)osteoporotic bone, 2) comminution, 3) intra-articular fracture, and4) short segment periarticular fracture [12,13] Locked plates and conventional plates rely on completely different mechanical principles to provide fracture fixation and in so doing they provide different biological environments for healing. Locked plates may increasingly be indicated for indirect fracture reduction, diaphyseal/metaphyseal fractures in osteoporotic bone, bridging severely comminuted fractures, and the plating of fractures where anatomical constraints prevent plating on the tension side of the bone. Conventional plates may continue to be the fixation method of choice for periarticular fractures which demand perfect anatomical reduction and to certain types of nonunions which require increased stability for union.[14] Conclusion Non-vascularised intramedullary fibula(along with debridement, decortication & shingling ) as a second internal biologic stable splint along with rigid osteosynthesis can achieve excellent Union for treatment of revision of difficult & neglected non -union of long bones. 9. Weber BG. Minimax fracture fixation. AO Masters Series. Stuttgart: Thieme Medical Publishers, 2004 10. Lin CL, Fang CK, Chiu FY, Chen CM, Chen TH. Revision with dynamic compression plate and cancellous bone graft for aseptic nonunion after surgical treatment of humeral shaft fracture. J Trauma. 2009 Dec;67(6):1393-6. 11. Hierholzer C, Sama D, Toro JB, Peterson M, Helfet DL. Plate fixation of ununited humeral shaft fractures: effect of type of bone graft on healing. J Bone Joint Surg. 2006; 88A: 1442-drv7 12. SmithWR, Ziran BH,Anglen JO, et al. Locking plates: tips and tricks. J Bone Joint SurgAm 2007;89(10):2298-307. PMID:17966158. 13. Wagner M. General principles for the clinical use of the LCP. Injury 2003;34 Suppl 2:B31-42. 14. Egol KA, Kubiak EN, Fulkerson E, Kummer FJ, Koval KJ. Biomechanics of locked plates and screws. J Orthop Trauma. 2004 Sep;18(8):488-93 Conflict of Interest: NIL Source of Support: NIL How to Cite this Article Tanna DD, Gawhale S, Shinde K, Gondalia V, Park H, Shyam AK. Intramedullary Fibula with Rigid Osteosynthesis in Revision of Neglected and multiple times Operated Non Union of Long Bones. Trauma International Jan - June 2017;3(1):27-31. 31 Trauma International Volume 3 Issue 1 Jan-June 2017 Page 27-31