WILAflow Elite Neonatal Ventilator. Non-invasive treatment for the most delicate patients.

Similar documents
WILAflow Elite Neonatal Ventilator. Non-invasive treatment for the most delicate patients.

TO THE OPERATOR AND PERSON IN CHARGE OF MAINTENANCE AND CARE OF THE UNIT:

Charisma High-flow CPAP solution

NI 60. Non-invasive ventilation without compromise. Homecare Pneumology Neonatology Anaesthesia. Sleep Diagnostics Service Patient Support

Introducing Infant Flow Advance SIPAP. By Joanne Cookson March 2008

CONTINUOUS POSITIVE AIRWAY PRESSURE (CPAP) DEFINITION

Carina. The compact wonder. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

NON INVASIVE LIFE SAVERS. Non Invasive Ventilation (NIV)

I. Subject: Continuous Positive Airway Pressure CPAP by Continuous Flow Device

POINT Peri-Operative Insufflatory Nasal Therapy

KOALA. Adult Bacterial Viral Filters. Medical Pty Ltd

Positive Pressure Therapy

Pap Settings. A review of fine tuning settings For patient comfort and compliance Wendy Cook BSRT Judy Salisbury RPGST

IICU Staff Meeting Minutes May 15 and 16, 2013 IICU Conference Room

Goldman Sachs JBWere Australasian Investment Forum New York - 7 March 2006

1 2 3 Based on the contents detailed below, assess the substantial equivalence to a legally marketed predicate device. In that case, the standards, et

ACCESSORIES AND DISPOSABLES

Emergency Medicine High Velocity Nasal Insufflation (Hi-VNI) VAPOTHERM POCKET GUIDE

How to write bipap settings

CURRENT TRENDS IN NON-INVASIVE VENTILATION. Disclosures. Why not invasive ventilation? Objectives. Currently available modes

10/17/2016 OXYGEN DELIVERY: INDICATIONS AND USE OF EQUIPMENT COURSE OBJECTIVES COMMON CAUSES OF RESPIRATORY FAILURE

English. Fealite Nasal Pillows System. User Manual

STATE OF OKLAHOMA 2014 EMERGENCY MEDICAL SERVICES PROTOCOLS

Prepared by : Bayan Kaddourah RN,MHM. GICU Clinical Instructor

GE Healthcare. Non Invasive Ventilation (NIV) For the Engström Ventilator. Relief, Relax, Recovery

Comparison of patient spirometry and ventilator spirometry

OG TAL ODUCT CA PR e e HEALTH

Natural performance. Introducing the BiPAP A30 - because ease of use and therapy efficacy are key to patient well-being

This is a pre-copyedited, author-produced PDF of an article accepted for publication in Journal of Neonatal Nursing following peer review.

High Flow Nasal Cannula Oxygen HFNC. Dr I S Kalla Department of Pulmonology University of the Witwatersrand

Sept ibreeze+ Series. Redefine your premium CPAP

Provider guide. DreamStation CPAP DreamStation CPAP Pro DreamStation Auto CPAP DreamStation BiPAP Pro DreamStation Auto BiPAP

experiences that matter

TNI 20: Breathe Easier without a Mask

Vancouver Coastal Health Guidelines for the use of Respiratory Equipment for Patients on Airborne Precautions in Acute Care Facilities

Lumis Tx: the all-in-one hospital ventilation solution

DreamStation. Provider guide

Acute Paediatric Respiratory Pathway

ROLE OF PRESSURE IN HIGH FLOW THERAPY

FY06 Full Year Update & Overview

FY07 Full Year Update & Overview

Dr. AM MAALIM KPA 2018

Therapy guide. A simple guide to managing your treatment of Obstructive Sleep Apnea

Mechanical Ventilation Principles and Practices

Practical Application of CPAP

PORTO 2 VENT CPAP OS. Operator s Manual. PORTO 2VENT CPAP OS System Operator s Manual Part Number Rev I

Pulmo Waves Device for respiratory physiotherapy

CRITICAL CARE AquaVENT

Performance. Connectivity. Comfort. A Breath of Innovation

Articles. The Advantages of Nebulization in the Treatment of Mechanically Ventilated Neonates. Kristin Smith, RRT-NPS

Nebulizers. Small Volume Nebulizers

XT series. Continuous Positive Airway Pressure

One intelligent solution

All About Positive Airway Pressure (PAP) Therapy

Provider guide. DreamStation

PRODUCT TRAINING TREND II

Neonatal and Pediatric Securement From Salter

Kugelman A, Riskin A, Said W, Shoris I, Mor F, Bader D.

Guidelines and Best Practices for Vapotherm High Velocity Nasal Insufflation (Hi-VNI ) NICU POCKET GUIDE

VENTILATOR PRODUCT ACCESSORIES CATALOG

Investment Highlights

Simulation 3: Post-term Baby in Labor and Delivery

Provide guidelines for the management of mechanical ventilation in infants <34 weeks gestation.

DIGITAL AUTO-TRAK + Bi-FLEX + AUTO Bi-LEVEL THE POWER OF. Sometimes when three come together the results can be quite extraordinary. Unique even.

One intelligent solution

SARASOTA MEMORIAL HOSPITAL DEPARTMENT POLICY

Day-to-day management of Tracheostomies & Laryngectomies

Scope This guideline is aimed at all healthcare professionals involved in the care of infants within the neonatal service.

Ultrasonic Humidifiers and Nebulisers

The Human Respiration System

Pediatrics in mechanical ventilation

Full Year Update FY2011 May 2011

PEPP Course: PEPP BLS Pretest

For personal use only

ACCESSORY GUIDE REV F

Complex Care Hub Manual: Continuous Positive Airway Pressure (CPAP) Ventilation

Continuous Aerosol Therapy

NIV and Aerosoltherapy

Obstructive Sleep Apnea Syndrome. Common sleep disorder causes high blood pressure and heart attacks

Monitor the patients disease pathology and response to therapy Estimate respiratory mechanics

9/15/2017. Disclosures. Heated High Flow Nasal Cannula: Hot Air or Optimal Noninvasive Support? Objectives. Aerogen Pharma

CoughAssist E70. More than just a comfortable cough. Flexible therapy that brings more comfort to your patients airway clearance

LUNG FUNCTION MEASUREMENT INSTRUMENT

The intelligent solution. System One Sleep Therapy System uses advanced intelligence to deliver excellent care while making patient management easy

acapella vibratory PEP Therapy System Maximizing Therapy Effectiveness, Empowering Patient Compliance

Forward Global Intensive Care System Company. Company Profile, Jul. 2015

Test Bank Pilbeam's Mechanical Ventilation Physiological and Clinical Applications 6th Edition Cairo

Clinical Quick Start Guide

Name and title of the investigators responsible for conducting the research: Dr Anna Lavizzari, Dr Mariarosa Colnaghi

2014 Full Year Results Presentation. Year ended 31 March 2014

Improving Care & Outcomes

Humidification of inspired gases in the mechanically ventilated patient

Airway Clearance Devices

Small Volume Nebulizer Treatment (Hand-Held)

Learning Objectives. 1. Indications versus contra-indications 2. CPAP versus NiVS 3. Clinical evidence

Bringing Advanced Technology to Airway Clearance

Stellar 100 Stellar 150

Transcription:

EN WILAflow Elite Neonatal Ventilator Non-invasive treatment for the most delicate patients. 0197

Infant Ventilation redefined A new generation in Infant Ventilation WILAflow Elite is a microprocessor controlled, noninvasive infant ventilator, providing most advanced and diversified non-invasive nasal ventilation modes, including apnea wakeup function and automatic leakage compensation. Precise levels of xygen WILAflow Elite delivers precise levels of 2 at positive pressure, which helps to keep alveoli open and thus improving oxygenation, while the infant breathes spontaneously. The variable WILAflow CPAP Generator helps to reduce the imposed WB (work of breathing) during inhalation and exhalation. Direct pressure setting WILAflow Elite directly sets the value of pressure for fully automatic pressure control. Direct xygen concentration setting WILAflow Elite uses electronic air/oxygen blender technology with one simple button to set precisely the value of the needed oxygen concentration and can autoproportionate oxygen and airflow. High-precision flow sensor and proportional valve equipped enable real-time feedback and oxygen concentration precision with +3%. Accurate and safe fresh gas delivery by iflow The Intelligent Closed-Loop Control System (iflow) was designed to protect the most fragile patients. iflow intelligently adjusts fresh gas flow and airway pressure in a closed loop. Proximal pressure monitoring (under the nose) and real-time leakage compensation enable stable pressure output. In case of leakage, iflow will compensate gas in real time to guarantee stable positive airway pressure. It can compensate leakage up to a maximum of 25%, which is incomparable by traditional CPAP devices. Safe ventilation weaning WILAflow Elite features S /, NCPAP and modes for safe ventilation weaning. WILAflow Elite 2

WILAflow Elite especially designed for the non-invasive ventilation of preterm infants or newborn infants predisposed with lung disease. Safe and reliable WILAflow Elite allows proximal pressure monitoring without being affected by mechanical dead space in the closed loop and compliance. The device accurately measures patient s airway pressure. This is the most recognizable method in the industry. ptional Abdominal Respiratory Sensor available The respiratory abdominal sensor enables the clinician to monitor for apnea/low breath rate in both and BiPhasic modes. The accessories include the reusable transducer and single-patient-use abdominal sensor. In the BiPhasic trigger mode, the respiratory abdominal sensor and transducer allow patient-triggered pressure assists with breath rate monitoring. Adequate humidification is essential to maintain airway clearance, optimize ventilation and improve patient comfort. Heated humidification is recommended for therapy The normal functions of the nose and air passages of the respiratory tract are to warm, moisten and filter the inhaled gases before they reach the lungs. In normal respiration, the nasal mucosa and upper airways provide 75% of the heat and moisture supplied to the smaller airways and alveoli. By the time air reaches the alveoli, the inspired gas warms to 37 C at 100% relative humidity (RH). With, the upper airways are not bypassed, but the high gas flows may be drying to the airways, especially to a neonate s underdeveloped lung. 3

WILAflow Elite Parameter Adjustable Range Step Ventilation Mode CPAP 1 13 cmh 2 1 3 cmh 2 ; 0,2 cmh 2 3 13 cmh 2 ; 0,5 cmh 2 PEEP 1 13 cmh 2 1 3 cmh 2 ; 0,2 cmh 2 3 13 cmh 2 ; 0,5 cmh 2 S Pinsp 3 20 cmh 2 3 8 cmh 2 ; 0,5 cmh 2 8 15 cmh 2 ; 1 cmh 2 S Papnea 3 20 cmh 2 3 8 cmh 2 ; 0,5 cmh 2 8 15 cmh2; 1 cmh 2 Manual Ventilation 3 20 cmh 2 3 8 cmh 2 ; 0,5 cmh 2 8 20 cmh 2 ; 1 cmh 2 S 3 25 L/min. 3 10 L/min; 0,5 L/min 10 25 L/min; 1 L/min Manual ventilation time Flow 1 20 s 1 s 0,5 20 L/min. 0,5 2 L/min; 0,1 L/min 2-10 L/min; 0,5 L/min 10 20 L/min; 1 L/min S 2 % 21 100 % 1 % Flush 2 23 100 % 1 % Flush oxygen ventilation time 30-120 s 30 s Ti 0,1 20 s. 0,01 s NCPAP NCPAP S S S 4

Parameters and Ranges Parameter Adjustable Range Step Ventilation Mode Respiratory Rate 1 120 bpm 1 bpm Tapnea FF; 10 30 s. 5 s S Rb 1 120 bpm 1 bpm S Pressure Fresh gas Flow 280 600 kpa 40 L/min Monitoring 2 % 0 100 % CPAP/EPAP Ppeak Pmean -10 100 cmh 2 I:E 1:1 1:10 Te Rsp Flow 0,4 30 s 0 200 bpm 0 40 L/min 5

WILAflow Elite Part Number Item Box / Qty. 101300 WILAflow Elite Infant CPAP Ventilator; including Vent Cart 1 100663 2 low pressure connecting tube, angle plug DIN, 3m 1 100664 2 low pressure connecting tube, angle plug DIN, 5m 1 100666 AIR low pressure connecting tube, angle plug DIN, 3m 1 100667 AIR low pressure connecting tube, angle plug DIN, 5m 1 101302 Signal Box/IEC incl. 2 Body Sensors 1 101301 Body Sensor VX010 100CM 5 101304 Hose Arm Assembly 1 101554 Supply Rack for Sterile Water (50cm) 1 Respiratory Humidification 101200 AIRcon Gen2 Humidifier, 230V 1 270777 BTS1204A Single limb system for, heated (i), A-adapter, autofill chamber, neo-adapter, generator, connecting tube for incubator (120cm, 10mm Ø) Connecting tube 40cm 10 CPAP Accessories 300710 WILAflow CPAP Mask, Size S 10 300711 WILAflow CPAP Mask, Size M 10 300708 WILAflow CPAP Mask, Size L 10 300709 WILAflow CPAP Mask, Size XL 10 300712 WILAflow Nasal Prong, Size S 10 300713 WILAflow Nasal Prong, Size M 10 300714 WILAflow Nasal Prong, Size L 10 6

rder Information Part Number Item Box / Qty. 300720 WILAbonnet, White, Size 000, 18 20 cm 10 300721 WILAbonnet, Grey, Size 00, 20 22 cm 10 300722 WILAbonnet, Pink, Size 0, 22 24 cm 10 300723 WILAbonnet, Brown, Size 1, 24 26 cm 10 300724 WILAbonnet, Yellow, Size 2, 26 28 cm 10 300725 WILAbonnet, Blue, Size 3, 28 30 cm 10 300726 WILAbonnet, Lite range, Size 4, 30 32 cm 10 300727 WILAbonnet, Green, Size 5, 32 34 cm 10 300728 WILAbonnet, Red, Size 6, 34 36 cm 10 300729 WILAbonnet, range, Size 7, 36 38 cm 10 300730 WILAbonnet, Turqoise, Size 8, 38 40 cm 10 300731 WILAbonnet, Dark Blue, Size 9, 40 42 cm 10 7

WILAmed GmbH Medizinische Geräte und Zubehör Gewerbepark Barthelmesaurach Aurachhöhe 5 7 91126 Kammerstein (Germany) Phone: +49 9178 996999-0 Fax: +49 9178 996778 info@wilamed.com www.wilamed.com Version 1.2 Stand: 01/10/2018 REF 8904060 All rights reserved. Subject to change.