Article (peer-reviewed)

Similar documents
Original Research. The Effect of temperature on the strength of luting cements Patil SG et al

Evaluation of Bond Strength of Silicone and Acrylic Resin Based Resilient Denture Liners Over A Period of Storage in Water.

Correlation between the Strength of Glass Ionomer Cements and Their Bond Strength to Bovine Teeth

Pulpal Protection: bases, liners, sealers, caries control Module C: Clinical applications

Bond strengths between composite resin and auto cure glass ionomer cement using the co-cure technique

Ketac Universal Aplicap

MDJ Evaluation the effect of eugenol containing temporary Vol.:9 No.:2 2012

The effect of a plastic-wrapped LED light curing unit and curing distance variances on diametral tensile strength of composite resin

Operative dentistry. Lec: 10. Zinc oxide eugenol (ZOE):

FujiCEM 2. Superior resin-modified glass. Force and Fusion technology. from GC. NEW SLIDE & LOCK system. ionomer luting cement with our innovative

Get in front of the 8 ball with the new Fuji VIII GP. The first auto-cure, resin reinforced glass ionomer restorative

BUILD IT FAST. MAKE IT LAST.

Anisotropy of Tensile Strengths of Bovine Dentin Regarding Dentinal Tubule Orientation and Location

G-COAT PLUS G-COAT PLUS GET THE BEST OF BOTH WORLDS WITH THE STROKE OF A BRUSH

BioCem Universal BioActive Cement. Designed specifically for pediatric dentistry

If you re still using a powder-liquid liner. Like VITREBOND...

Acknowledgments Introduction p. 1 Objectives p. 1 Goals p. 2 History of Dental Materials p. 3 The Oral Environment p. 4 Characteristics of the Ideal

how to technique How to treat a cracked, but still inact, cusp. Disadvantages. 1 Issue Full coverage crown. >>

Bond Strength of Composite Resin Luting Cements to Fiber-reinforced Composite Root Canal Post

There are essentially three major aspects

DPI Luting Cement. DPI Restorative Cement

Bonding to dentine: How it works. The future of restorative dentistry

Dowel restorations Treatment with a post and core

Posterior Adhesive Dentistry

In nitro bond strength of cements to treated teeth

lec: Dental material dr. Aseel Mohammed Filling material

Filling materials are used to replace missing parts of the tooth.

Advanced restorative techniques and the full mouth reconstruction: the use of gold copings in bridgework

Bond strength test of acrylic artificial teeth with prosthetic base

G-CEM LinkAce. The new strength in self-adhesive cement

Howard E. Strassler, DMD University of Maryland School of Dentistry

ISO 1567 INTERNATIONAL STANDARD. Dentistry Denture base polymers. Art dentaire Polymères pour base de prothèses dentaires. Third edition

The full veneer crown is one of the most important

Treatment Options for the Compromised Tooth

Luting Cement. in the Clicker Dispenser. Technical Product Profile Ketac Cem Plus

ISO INTERNATIONAL STANDARD. Dentistry Reversible-irreversible hydrocolloid impression material systems

Scientific Documentation

Annotation to the lesson 21 Topic: Methods of provisory crowns fabrication. Chair-side technique. Evaluation of

Department of Prosthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand

1. Introduction Technical data In-vitro investigations with Systemp.link Clinical assessment Biocompatibility...

Clinical Studies of Dental Cements: III. Seven Zinc Oxide-Eugenol Cements Used for Temporarily Cementing Completed Restorations

Fuji ORTHO LC CAPSULE. 1 Capsule = 1 Full Arch Bonded

Magnification so what!

Fuji II LC. A Perfect Choice

MDJ Comparative evaluation of compressive strength Vol.:14 No.:1 2017

Remaining dentin thickness Shallow cavity depth Preparation 0.5 mm into dentin (ideal depth) Moderate cavity depth Remaining dentin over pulp of at le

Immediate versus Delayed Force Application after Orthodontic Bonding; An In Vitro Study

ORIGINAL RESEARCH. Sandhya CA Shyam Lohakare, Pushpa Vinay Hazarey ABSTRACT

Effect of Shade and Thickness of Porcelain Veneers on Depth of Cure of Light-Cured Resin-Based Luting Cement

CARIES STABILIZATION AND TEMPORARY RESTORATION

XP BOND IN SELF-CURE MODE USED FOR LUTING PORCELAIN RESTORATIONS:

The Influence of Some Dentin Primers on Calcium Hydroxide Lining Cement

Core build-up using post systems

Individual Tools for Controlling and Positioning Porcelain Veneers: Easychecker The Aesthetic Key Ralf Barsties, CDT and Dr.

Should Implants Be Connected to Natural Teeth

Glass Ionomer Restoratives & Cements. Glass Ionomers FLOWABLE NANO HYBRID COMPOSITE

Endodontics. Lec.7 د. حسن الرماحي 5 th class. Obturation techniques

TOOTH - Crown - Lithium disilicate - Non-retentive preparation - Variolink Esthetic - Adhese Universal

Professor and Head, Department of Pedodontics, D.J. College of Dental Sciences and Research, Niwari Road, Modinagar, Uttar Pradesh, India.

Alternatives to Amalgam

TOOTH PREPARATION. (Boucher's Clinical Dental Terminology, 4th ed, p239)

EQUIA. Self-Adhesive, Bulk Fill, Rapid Restorative System

Ceramic Based Aesthetic CAD/CAM Restorative

Polycarbonate Crowns for Primary teeth Revisited. Restorative options, Technique & Case reports

A Comparative Study between Bond Strength of Rebonded and Recycled Orthodontic Brackets

OT EQUATOR CASTABLE Single Attachment for Overdentures

RelyX Unicem Self-Adhesive Universal Resin Cement Frequently Asked Questions

BASIC Level 1 Practitioner Certification

Ketac Nano Light-Curing Glass Ionomer Restorative. An esthetic glass ionomer. Fewer steps. Faster treatment.

Introduction to Layering with Filtek Supreme Plus Universal Restorative. Filtek. Supreme Plus Universal Restorative

DENTAL MATERIALS STUDY GUIDE

Calibra. Cements. The Simple Choice for Easy Cleanup

DUO-LINK UNIVERSAL KIT

Used Products. Variolink N LC. Proxyt fluoride-free. OptraStick. Ivoclean. Monobond N. OptraDam. N-Etch. Tetric N-Bond.

IN VITRO COMPARISON OF RETENTION AND MARGINAL LEAKAGE OF PROVISIONAL CROWNS CEMENTED WITH PROVISIONAL CEMENT ENRICHED WITH THREE DIFFERENT ADDITIVES

SDR has proven reliability in high C-factor cavities 2

A Survey on the Current Trends in the Use of Different Core Buildup Materials and Luting Agents in General Dental Practice

THE FUTURE DEMANDS THE RIGHT EQUIPMENT CLEARFIL SE BOND 2

Lect. Pre. Clin

Fuji BULK. Robust. Rapid. Remarkable.

OCCLUSION IN NEWLY FABRICATED BRIDGE*

ON THE MICROHARDNESS AND YOUNG S MODULUS OF HUMAN TEETH

GLUMA Comfort + Desensitizer

Root Surface Protection Simple. Effective. Important.

Stainless Steel Crowns

IMPRESSION MATERIALS

A rationale for retrievability of fixed, implant-supported prostheses: a complication-based analysis.

Keep. simple. 3M RelyX Cements

Physico-mechanical properties of a nanofilled glass ionomer cement

illustrated technique guide

Essentials of. Dental Assisting. Edition 6. Debbie S. Robinson Doni L. Bird

INFLUENCE OF APPLICATION SITE OF PROVISIONAL CEMENT ON THE MARGINAL ADAPTATION OF PROVISIONAL CROWNS

FIVE THINGS YOU NEED TO KNOW ABOUT GLASS IONOMERS

Complex esthetic and functional rehabilitation using glass-ceramic materials - long-term documentation of a restoration

The Facts About Fillings

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

guidelines Clinical guidelines crown work Smile... first impressions last

TOOTH - Crown - Lithium disilicate - Retentive preparation - Super- and equigingival - Visible margin - Variolink Esthetic - ExciTE F DSC

and get a Pentamix TM Lite free *

All teeth should be restored with the most conservative restoration that satisfies the patient s esthetic and functional requirements.

Transcription:

Title The effect of variability in the powder/liquid ratio on the strength of zinc phosphate cement Author(s) McKenna, Jill E.; Ray, Noel J.; McKenna, Gerald; Burke, Francis M. Editor(s) Abdalla, Ali I. Publication date 2011-11 Original citation Type of publication Link to publisher's version Rights Jill E. McKenna, Noel J. Ray, Gerald McKenna, and Francis M. Burke, The Effect of Variability in the Powder/Liquid Ratio on the Strength of Zinc Phosphate Cement, International Journal of Dentistry, vol. 2011, Article ID 679315, 4 pages, 2011. doi:10.1155/2011/679315 Article (peer-reviewed) http://www.hindawi.com/journals/ijd/2011/679315/ http://dx.doi.org/10.1155/2011/679315 Access to the full text of the published version may require a subscription. Copyright 2011 Jill E. McKenna et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/3.0/ Item downloaded http://hdl.handle.net/10468/551 from Downloaded on 2019-03-22T04:53:33Z

Hindawi Publishing Corporation International Journal of Dentistry Volume 2011, Article ID 679315, 4 pages doi:10.1155/2011/679315 Research Article The Effect of Variability in the Powder/Liquid Ratio on the Strength of Zinc Phosphate Cement Jill E. McKenna, Noel J. Ray, Gerald McKenna, and Francis M. Burke Restorative Dentistry, Cork University Dental School and Hospital, University College Cork, Ireland Correspondence should be addressed to Gerald McKenna, g.mckenna@ucc.ie Received 6 July 2011; Revised 27 October 2011; Accepted 27 October 2011 Academic Editor: Ali I. Abdalla Copyright 2011 Jill E. McKenna et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Aim. To investigate (a) variability in powder/liquid proportioning and (b) effect of variability on diametral tensile strength (DTS), in a zinc phosphate cement. Statistical analyses (α = 0.05) were by Student s t-test in the case of powder/liquid ratio and oneway ANOVA and Tukey HSD for pair-wise comparisons of mean DTS. The Null hypotheses were that (a) the powder-liquid mixing ratios would not differ from the manufacturer s recommended ratio (b) DTS of the set cement samples using the extreme powder/liquid ratios would not differ from those made using the recommended ratio. Methodology. 34 dental students dispensed the components according to the manufacturer s instructions. The maximum and minimum powder/liquid ratios, together with the manufacturer s recommended ratio, were used to prepare samples for DTS testing. Results. Powder/liquid ratios ranged from 2.386 to 1.018. The mean ratio (1.644) was not significantly different from the recommended value of 1.718 (P = 0.189). DTS values for the maximum and minimum ratios were both significantly different from each other (P <0.001) and from the mean value obtained from the recommended ratio (P <0.001). Conclusions. Variability exists in powder/liquid ratio for hand dispensed zinc phosphate cement. This variability can affect the DTS of the set material. 1. Introduction Indirect restorations play an important role in clinical dentistry. Whilst clinicians often spend considerable time choosing materials or type of restorations, the cementation process is often considered less important and manufacturer s instructions modified or ignored [1]. Luting materials are necessary to retain such restorations on teeth and to prevent leakage at their margins [2]. One such material is zinc phosphate cement which is used routinely by almost one-third of UK practitioners [3]. Clinically, the cement is presented as powder and liquid components which must be mixed together prior to application to the restoration or the tooth. Often the proportions of the two elements used are measured by eye or with operator-dependent measuring systems. They are then mixed together in varying environments (temperature and humidity) under differing mixing conditions time and manipulation technique [4]. While low-grade mixing errors (<10 20%) may not have serious implications regarding the integrity of traditional luting agents, there is concern regarding high-grade errors [1]. Such errors are likely to occur with less experienced operators, such as undergraduate dental students and inexperienced dental nurses. As a measure of mechanical integrity of the set cement, compressive strength has been found to increase with the amount of powder mixed with a constant amount of liquid [4 8]. In addition, diametral tensile strength (DTS) is a well-established and reproducible measure of mechanical integrity in very brittle materials such as zinc phosphate cement and has been extensively used in the testing of appropriate dentally related materials [9 11]. The aim of this study was to (a) investigate whether high-grade powder-liquid proportioning errors might occur in a cohort of inexperienced dental undergraduate students mixing zinc phosphate cement and (b) determine the effect of any such variability on the diametral tensile strength of the set material. The Null hypotheses were that (a) the

2 International Journal of Dentistry powder-liquid mixing ratios observed would not differ from the manufacturer s recommended ratio and (b) DTS of the set cement samples using the extreme powder/liquid ratios observed would not differ from those made using the manufacturer s recommended ratio. 2. Methodology The entire third year undergraduate dentistry class from a dental school in Ireland was invited to participate in the study. Thirty four students contributed to the experiment, none of whom had previous experience of working with zinc phosphate cement but had experience of mixing other dental materials including glass ionomer cement in the clinical environment. Each student received verbal and written directions in measuring powder and liquid components according to the manufacturer s instructions (Fleck s Cement, Mizzy, Cherry Hill, NJ, USA). The instructions stated that 0.8 g of powder should equate with 2 fillings to the shoulder of the powder cap dome and 0.3 ml liquid should equate with 12 drops of liquid (luting ratio). The students measured the powder and liquid using the powder cap and liquid dropper onto a preweighed plastic container and the mass of each was recorded (Mettler AE 100 balance, Mettler Instruments AG, Greifensee, Zurich). A calibrated pipette was used to determine the density of the cement liquid yielding the mass equivalent of the manufacturer s recommended volume of 0.3 mls and a powder/liquid ratio (m/m) of 1.718. The observed maximum (2.386) and minimum (1.018) powder/liquid ratios, together with the manufacturer s recommended ratio (m/m), were used subsequently by a single experienced dental clinician to prepare cylindrical samples (n = 3 34), of nominal dimensions 6 mm 3 mm, using a stainless steel split mould. The samples were hand mixed on a chilled glass slab and the mix transferred and packed into the split mould. The samples were left to initially mature (60 mins) before being removed from the mould. Excess material was removed using a sharp scalpel. The specimens were further matured in deionised water (37 ± 2) Cfor48 hours. Before testing, each specimen was dried gently on all sides using soft tissue paper and the diameter and height measured using a micrometer gauge. Compression across a diameter was carried out using a universal testing machine, H10KS (Tinius Olsen), at a constant crosshead speed of 0.75 mm/min. Failure load data were converted to DTS using the expression σ = 2P/πdl (σ = diametral tensile strength, P = load at failure, d = diameter of cylinder, and l = height of cylinder). All testing was at 23 ± 2 C. The Null hypotheses were that (a) the powder-liquid mixing ratios observed would not differ from the manufacturer s recommended ratio and (b) DTS of the set cement samples would not differ from those made using the manufacturer s recommended ratio. Statistical analyses (α = 0.05) were by Student s t-test in the case of powder/liquid ratio and one-way ANOVA and Tukey HSD for for pair-wise comparisons of mean DTS (R version 2.8.0 R Foundation for Statistical Computing). Appropriate tests were carried out for normality and constant variability. Table 1: Extreme powder/liquid mixing ratios & corresponding mean diametral tensile strength. Maximum Minimum Mean Manufacturer s Powder/liquid 1.644 2.386 1.018 1.718 ratio, m/m (SD) (341) Diametral tensile 7.19 2.65 6.01 strength, MPa (SD) (1.50) (1.01) (1.30) 3. Results The extreme powder/liquid mixing ratios (m/m) observed from the student cohort, together with the manufacturer s recommending ratio, and corresponding data regarding DTS are presented in Table 1. The mean powder/liquid ratio obtained for the student cohort was not significantly different from the manufacturer s recommended value (P = 0.189). The mean DTS values recorded for the maximum and minimum ratios for the student cohort were significantly different from that obtained from the manufacturer s recommended powder/liquid ratio (P <0.001) and from each other (P <0.001). 4. Discussion It is clear that high-grade powder-liquid proportioning errors were observed in this cohort of dental undergraduate students in the sense that the extreme powder-liquid ratios resulted in significant impacts on DTS. These proportioning errors have occurred notwithstanding explicit verbal and written instructions given immediately before the mixing process. While it is attractive to attribute this effect to inexperience, as might be relevant to undergraduate dental students and inexperienced dental nursing staff, more substantial and quantifiable concerns must address the mixing methodology. Ideally, the mixing process should be fail safe in that it should only be possible to mix material correctly, or not at all. In this regard, a number of opportunities for error present. The volume of powder delivered using volume dispensation is very operator dependent and variations can be common due to the differences in cement powder packing densities when filling the scoop [12, 13]. For dispensing the liquid the opportunity for inaccuracy is potentially even greater. The amount of liquid expressed is dependent on the manner in which the bottle is held and the force exerted on it. Excessive force can cause a stream of liquid to be expressed rather than a series of drops and air bubbles can further complicate measurement [13]. Operators often tend to mix cements and other restorative materials by experience, adding extra powder or liquid to gain the consistency or properties they desire [14]. A report quoted relatively good intraoperator consistency in mixing zinc phosphate cement (single commercial product) among a cohort of 40 qualified dental nurses in the UK but little intra-operator consistency [15]. Clearly, such a report is not conducive to the expectation of acceptable performance among inexperienced operators and begs the overall question

International Journal of Dentistry 3 of whether an alternative approach should be used in the manner of a standard operating protocol per product. A plausible solution to addressing variability in powder/liquid ratio (and presenting the possibility of consistent mixing) is the encapsulation of cement components (single-use capsules) which certain manufacturers have done with zinc phosphate and other luting cements such as glass ionomer [16]. Encapsulation would also remove the problem of solvent evaporation from the cement liquid with possible phosphate deposition yielding the liquid unusable. It is, however, unclear what parameters the manufacturer s recommended powder/liquid address. Presumably, the resultant mixture is required to be sufficiently thin to wet the adherend but with the ability to yield acceptable strength on setting. A report on the effect of powder/liquid ratio on the clinical performance of resin-modified glass ionomer cement [17] indicates that higher powder/liquid ratios compromise surface wetting with an increased incidence of subsequent retention failures when used as a tooth restorative. The reported mean value for DTS, mixed according to the manufacturer s ratio, was generally consistent with previously reported values for other brands of zinc phosphate cement relating to similar specimen dimensions and storage [18, 19]. This would suggest that the observed low value obtained from the minimum powder/liquid ratio may be generalised as inappropriate proportioning. The value was less than 38% of the strength associated with the manufacturer s mixing ratio and must raise concerns regarding mechanical adequacy of the set material. Apart from concerns regarding compromised mechanical properties, there are likely clinical consequences to the use of an inappropriate powder to liquid ratio. For example, incorporation of too much powder into the luting cement may result in a thick mix of cement which could make complete seating an indirect restoration difficult [20]. This could result in open margins and/or a high restoration which could cause patient discomfort in the short term and the failure of the restoration in the long term. While the use of encapsulated products might appear attractive to obviate arbitrary mixing ratios with attendant problems, a reported comparison of an encapsulated zinc phosphate cement with a hand-mixed analogue highlighted certain deficiencies in the encapsulated material [21, 22] No significant advantages in terms of reliability or strength were observed in the encapsulated product. In addition, the latter was observed to be more porous than the hand-mixed material, most likely due to the entrapment of air during the relatively vigorous mechanical trituration. 5. Conclusions Null hypotheses (a) and (b) are rejected. High-grade proportioning errors relating to Fleck s Cement, for a luting consistency, were observed among a cohort of dental undergraduate students. These errors resulted in significant differences between the DTS values of the set cement and those which relate to the manufacturer s recommended ratio. Apart from compromised mechanical performance resulting from inappropriate proportioning, incorporation of too much powder into the luting cement may result in a thick mix of cement which could make complete seating an indirect restoration difficult. This could result in open margins and/or a high restoration. Routine encapsulation of zinc phosphate cement components, in the form of single-use disposable capsules, is suggested as a method of addressing variability in proportioning powder-liquid cements especially amongst inexperienced operators. References [1] M. Behr, M. Rosentritt, H. Loher et al., Changes of cement properties caused by mixing errors: the therapeutic range of different cement types, Dental Materials, vol. 24, no. 9, pp. 1187 1193, 2008. [2] F. J. Burke, Evaluating restorative materials and procedures in dental practice, Advances in Dental Research,vol.18,no.3,pp. 46 49, 2005. [3] P. A. Brunton, G. J. Christensen, S. W. Cheung, F. J. T. Burke, andn.h.f.wilson, Contemporarydentalpracticeinthe UK: indirect restorations and fixed prosthodontics, British Dental Journal, vol. 198, no. 2, pp. 99 103, 2005. [4] G. J. P. Fleming, R. M. Shelton, G. Landini, and P. M. Marquis, The influence of mixing ratio on the toughening mechanisms of a hand-mixed zinc phosphate dental cement, Dental Materials, vol. 17, no. 1, pp. 14 20, 2001. [5] J. R. Savignac, C. W. Fairhurst, and G. Ryge, Strength, solubility and disintegration of zinc phosphate cement with clinically determined powder-liquid ratio, The Angle Orthodontist, vol. 35, pp. 126 130, 1965. [6] W. B. Eames, S. D. Monroe, J. D. Roan, and S. J. O Neal, Proportioning and mixing of cements: a comparison of working times, Operative Dentistry, vol. 2, no. 3, pp. 97 104, 1977. [7] T. R. Walton, The flow properties of zinc phosphate cement: an argument for changing the standard, Australian Dental Journal, vol. 25, no. 4, pp. 215 218, 1980. [8] G. C. Paffenbarger, W. T. Sweeney, and A. Isaacs, A preliminary report on the zinc phosphate cement, Journal of the American Dental Association, vol. 20, pp. 1960 1922, 1933. [9] X. S. Timoshenko, Theory of Elasticity, McGraw-Hill, New York, NY, USA, 1st edition, 1934. [10] R. G. Fonseca, T. P. Artusi, J. G. dos Santos, and G. L. Adabo, Diametral tensile strength of dual-curing resin cements submitted exclusively to autopolymerization, Quintessence International, vol. 38, no. 9, pp. e527 e531, 2007. [11] I. S. Medeiros, M. N. Gomes, A. D. Loguercio, and L. E. Filho, Diametral tensile strength and Vickers hardness of a composite after storage in different solutions, JournalofOral Science, vol. 49, no. 1, pp. 61 66, 2007. [12] G. J. Mount, Instructions for dental assistants, in An Atlas of Glass-Lonomer Cements: A Clinician s Gui, pp. 123 131, Martin Duntz, London, UK, 2nd edition, 1994. [13] R. W. Billington, J. A. Williams, and G. J. Pearson, Variation in powder/liquid ratio of a restorative glass-ionomer cement used in dental practice, British Dental Journal, vol. 169, no. 6, pp. 164 167, 1990. [14] J. F. McCabe and A. W. Walls, Applied Dental Materials, chapter28, Blackwell, London, UK, 9th edition, 2008. [15] G. J. P. Fleming, P. M. Marquis, and A. C. C. Shortall, The influence of clinically induced variability on the distribution of compressive fracture strengths of a hand-mixed zinc phosphate dental cement, Dental Materials,vol.15,no.2,pp.87 97, 1999.

4 International Journal of Dentistry [16] A. H. Dowling and G. J. P. Fleming, Is encapsulation of posterior glass-ionomer restoratives the solution to clinically induced variability introduced on mixing? Dental Materials, vol. 24, no. 7, pp. 957 966, 2008. [17] A.D.Wilder,A.A.Boghosian,S.C.Bayne,H.O.Heymann,J. R. Sturdevant, and T. M. Roberson, Effect of powder/liquid ratio on the clinical and laboratory performance of resinmodified glass-ionomers, Journal of Dentistry, vol. 26, no. 4, pp. 369 377, 1998. [18] E. A. Galun, N. Saleh, and I. Lewinstein, Diametral tensile strength and bonding to dentin of type I glass ionomer cements, The Journal of Prosthetic Dentistry,vol.72, no.4,pp. 424 429, 1994. [19] S. Ban and K. J. Anusavice, Influence of test method on failure stress of brittle dental materials, JournalofDentalResearch, vol. 69, no. 12, pp. 1791 1799, 1990. [20] S. A. Osman, J. F. McCabe, and A. W. Walls, Film thickness and rheological properties of luting agents for crown cementation, The European Journal of Prosthodontics and Restorative Dentistry, vol. 14, no. 1, pp. 23 27, 2006. [21] G. J. P. Fleming, A. C. C. Shortall, R. M. Shelton, and P. M. Marquis, Encapsulated verses hand-mixed zinc phosphate dental cement, Biomaterials, vol. 20, no. 22, pp. 2147 2153, 1999. [22] G. J. P. Fleming, G. Landini, and P. M. Marquis, Properties of encapsulated and hand-mixed zinc phosphate dental cement, American Journal of Dentistry, vol. 15, no. 2, pp. 91 96, 2002.