Immediate versus Delayed Force Application after Orthodontic Bonding; An In Vitro Study

Similar documents
A Comparative Study between Bond Strength of Rebonded and Recycled Orthodontic Brackets

Orthodontic In Vivo Bond Strength: Comparison with In Vitro Results

Bonding characteristics of a self-etching primer and precoated brackets: an in vitro study

Shear Bond Strength of Acidic Primer, Light-Cure Glass Ionomer, Light-Cure and Self Cure Composite Adhesive Systems - An In Vitro Study

COMPARISON OF SHEAR BOND STRENGTH OF NEW AND RECYCLED BRACKETS WITH DIFFERENT MESH DESIGNS

ORIGINAL RESEARCH. Sandhya CA Shyam Lohakare, Pushpa Vinay Hazarey ABSTRACT

Comparison of Shear Bond Strength of Metal Brackets Bonded to Porcelain Surface using Different Surface Conditioning Methods: An in vitro Study

Early Shear Bond Strength of a One-step Self-adhesive on Orthodontic Brackets

The Effect of Different Bracket Base Cleaning Method on Shear Bond Strength of Rebonded Brackets

The effect of different force magnitudes for placement of orthodontic brackets on shear bond strength, in three adhesive systems

S. Shear bond strength and debonding characteristics of metal and ceramic

Original Research. Shear bond strength of new self etching primer (RSEP) Sorake A et al

A Comparison of Bond Strength Between Directand Indirect-bonding Methods

Effect of Self-etchant ph on Shear Bond Strength of Orthodontic Brackets: An in vitro Study

MDJ Evaluation the effect of eugenol containing temporary Vol.:9 No.:2 2012

Various whitening systems are currently being

Shear bond strength of a new polycarbonate bracketan in vitro study with 14 adhesives

Glass Ionomer Cement as an Orthodontic Bonding Agent

Bonding to molars the effect of etch time (an in vitro study)

Adhesive Thickness Effects on the Bond Strength of a Light- Cured Resin-Modified Glass Ionomer Cement

The effect of orthodontic bracket pad shape on shear bond strength, an in vitro study on human enamel

Even though the acid-etching technique is useful

Bond Strength of Direct and Indirect Bonded Brackets After Thermocycling

ORTHOdontics SLIDING MECHANICS

A comparison of shear bond strength and mean survival time between treated and untreated mesh backed stainless steel brackets, an in-vitro assessment.

BOCL-01: Bonding Materials Checklist

Incognito Appliance System Bonding Protocols Step-by-Step Procedures


Efficient Bonding Protocol for the Insignia Custom Bracket System

Comparison of shear bond strength and adhesive remnant index between precoated and conventionally bonded orthodontic brackets

Assessment of the Confidence of the Adhesive Remnant Index Score With Different Methods

The acid-etch technique has been widely used in

Bond Strength of Disinfected Metal and Ceramic Brackets:

Evaluation of bond strength of orthodontic brackets without enamel etching

Bond strength assessment of metal brackets bonded to porcelain fused to metal surface using different surface conditioning method

A Method for Stabilizing a Lingual Fixed Retainer in Place Prior to Bonding

COMPARISON BETWEEN MOLAR BANDS, BONDABLE TUBES AND BONDABLE TUBES WITH FLOWABLE COMPOSITE

Effects of Two Soft Drinks on Shear Bond Strength and Adhesive Remnant Index of Orthodontic Metal Brackets

Transbond IDB Pre-Mix Chemical Cure Adhesive Lunch and Learn

In nitro bond strength of cements to treated teeth

Prophylaxis-based dental treatment: cavity prophylaxis using enamel-protective bracket attachment

AN 8 MONTH CLINICAL TRIAL OF BOND FAILUES WITH FOUR DIFFERENT TYPES OF ORTHODONTIC ADHESIVES

Shear bond strength of ceramic and metallic orthodontic brackets bonded with self-etching primer and conventional bonding adhesives

How to place a lower bonded retainer

With judicious treatment planning, the clinical

The words adhesionpromoters werefirstusedto

The procedure for bonding orthodontic brackets

Effects of silanation time on shear bond strength between a gold alloy surface and metal bracket

Dental Research Journal

Comparison of Shear Bond Strength of Orthodontic Brackets Bonded to Enamel Prepared By Er:YAG Laser and Conventional

Transbond PLUS Color Change Adhesive Lunch and Learn

Bond strengths between composite resin and auto cure glass ionomer cement using the co-cure technique

The Rondeau System. Brackets, Bands, Buccal Tubes and Archwires. Orthodontic supplies recommended by Dr. Brock Rondeau

Anisotropy of Tensile Strengths of Bovine Dentin Regarding Dentinal Tubule Orientation and Location

Bond strengths of different orthodontic adhesives after enamel conditioning with the same self-etching primer

Shear Bond Strength of Orthodontic Brackets Cured with Different Light Sources under Thermocycling

INDICATIONS. Fixed Appliances are indicated when precise tooth movements are required

In Vitro Evaluation of a Moisture-Active Adhesive for Indirect Bonding

Influence of saliva contamination on the shear bond strength of adhesives on enamel

Evaluation of Degree of Cure and Shear Bond Strength of a Color Changing Light Cure Adhesive

Objective: The aim of this study was to assess the impact of blood contamination on shear

Ketac Universal Aplicap

[Downloaded free from on Wednesday, September 28, 2016, IP: ]

Effect of light-curing units in shear bond strength of metallic brackets: an in vitro study

Bond Strength of Composite Resin Luting Cements to Fiber-reinforced Composite Root Canal Post

Correction of severe tooth rotation by using two different orthodontic appliances: Report of two cases

ADHESIVES/CEMENTS. Adhesives... F-2 Band Cements... F-7 Curing Light... F-9 Auxiliaries... F-9 Conditioners... F-11

Scanning Electron Microscopy Evaluation of the Bonding Mechanism of a Self-etching Primer on Enamel

Effects of selenium-containing sealant and adhesive system on the shear bond strength of orthodontic brackets

Comparative Evaluation of Fracture Resistance of Dental Amalgam, Z350 Composite Resin and Cention-N Restoration In Class II Cavity

ABSTRACT INTRODUCTION /jp-journals

Dual Force Cuspid Retractor

Arch dimensional changes following orthodontic treatment with extraction of four first premolars

Temporary Bite Opening with Güray Bite Raiser

The Tip-Edge appliance and

Improving Tensile Bond Strength of Orthodontic Bracket by Applying Papain Gel as an Deproteinization Agent

The Reinforced Removable Retainer

Comparison of three different orthodontic wires for bonded lingual retainer fabrication

The effectiveness of paint remover to resin adhesive residue on base mesh of metal bracket

Various composite resins are used in orthodontic

6. Timing for orthodontic force

Bond Strength of Amorphous Calcium Phosphate Containing Orthodontic Composite Used as a Lingual Retainer Adhesive

Flowable Composite for Orthodontic Bracket Bonding (in vitro study)

Three-dimensional measurement of enamel loss caused by bonding and debonding of orthodontic brackets. VAN WAES, H, MATTER, T, KREJCI, Ivo.

Evaluation and comparison of shear bond strength of new and rebonded orthodontic brackets having various mesh base designs: An in vitro study

Treatment of an open bite case with 3M Clarity ADVANCED Ceramic Brackets and miniscrews.

Recommended IDB Protocol

SHEAR BOND STRENGTH OF SOME SEALANTS UNDER SALIVA CONTAMINATION

An in vitro study of the bond strength of light-cured glass ionomer cement in the bonding of orthodontic brackets

Microleakage under Metallic and Ceramic Brackets Bonded with Orthodontic Self-Etching Primer Systems

The stability of orthodontic treatment is a major

ALEXANDER DAVIS CRANFORD ANDRE F. H. FERREIRA, CHAIR ALEXANDER JACOBSON P. LIONEL SADOWSKY A THESIS

An In-Vivo Comparison Of The Efficacy Between Direct And Indirect Bonding Methods

Non-osseointegrated. What type of mini-implants? 3/27/2008. Require a tight fit to be effective Stability depends on the quality and.

Evaluation of shear strength of lingual brackets bonded to ceramic surfaces

Buccally Malposed Mesially Angulated Maxillary Canine Management

Microleakage and shear bond strength of orthodontc brackets bonded to hypomineralized enamel following different surface preparations

Office reconditioning of stainless steel orthodontic attachments

Lower Anterior Crowding Correction by a Convenient Lingual Methodjerd_

In Vitro Investigation of Indirect Bonding with a Hydrophilic Primer

Transcription:

Journal of Dentistry, Tehran University of Medical Sciences Original Article Immediate versus Delayed Force Application after Orthodontic Bonding; An In Vitro Study M. Basafa 1, F. Farzanegan 2 1 Professor, Department of Orthodontics, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran 2 Assistant Professor, Department of Orthodontics, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran Corresponding author: Dr. M. Basafa, Department of Orthodontics, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran. m_basafa52@yahoo.com Received: 18 July 2005 Accepted: 26 January 2006 Abstract: Statement of Problem: Bracket de-bonding during initial orthodontic archwire placement immediately after bracket set up or following re-bonding a single bracket can be a clinical concern. Purpose: The aim of this in vitro study was to assess the effect of time on the shear bond strength of a no-mix orthodontic composite adhesive. Materials and Methods: Seventy freshly extracted human upper first premolars were collected and stored in normal saline solution. The teeth were cleaned, polished, and randomly separated into 7 groups of 10. First premolar mesh-backed standard edgewise brackets were bonded to all specimens using a no-mix orthodontic composite adhesive. In the first 6 groups, the brackets were de-bonded 2, 5, 10, 15, 30 and 60 minutes after the primary setting time and the shear bond strengths were determined with the Universal testing machine. The teeth in group 7 were stored in 100% humidity at 37 o C for 24 hours before de-bonding. Data were statistically analyzed with one-way ANOVA and the Duncan multiple range analyses via SPSS software. Results: The minimum shear bond strength of 14.03 MPa was observed in group 1. A statistically significant difference was found between the shear bond strength of group 1 and the other groups (P<0.05). The shear bond strength increased significantly with time up to the first 5 minutes after bonding, but did not change afterwards. Conclusion: The bracket and composite adhesive used in this study demonstrated initial bond strengths of sufficient magnitude to withstand the immediate application of orthodontic forces, even 2 minutes after the primary setting time. Therefore, the operator should not be concerned with bracket de-bonding due to primary arch wire placement during the first minutes after bracket set up or following re-bonding a single bracket. Key Words: Shear bond strength; Universal testing machine; No-mix composite; Invitro study Journal of Dentistry, Tehran University of Medical Sciences, Tehran, Iran (2006; Vol:3, No.1) INTRODUCTION The acid etch bonding technique was first introduced in 1955 by Buonocore [1]. From then on the concept of bonding various resins to enamel has developed applications in all fields of dentistry including bonding of orthodontic brackets. According to the literature the rate of bracket failure varies from 1 to 7.2 percent [2-5]. Bracket failure may develop for different reasons and in different stages of treatment. Reynolds reported that the necessary bond strength (BS) for orthodontic brackets to withstand de-bonding in normal conditions is between 5.9 to 8.7 MPa [6]. The BS of different bonding materials, the effect of etch time the role of debonding devices in 24 2006; Vol. 3, No. 1

Force Application after Orthodontic Bonding assessing BS, and the effect of thermocycling and tooth type on BS, have been previously demonstrated [7-17]. The aim of this in vitro study was to assess the effect of time on the shear bond strength of a no-mix orthodontic composite adhesive, i.e. Dentaurum, to determine whether the initial bond strengths are of sufficient magnitude to withstand the immediate application of orthodontic forces after bracket set up or following rebonding a de-bonded bracket MATERIALS AND METHODS This investigation was an in vitro experimental study. The sample consisted of seventy human upper first premolars extracted for orthodontic purposes. The criteria for tooth selection included intact buccal enamel that had not been subjected to any pretreatment chemical agents, eg, hydrogen peroxide, with no cracks due to the pressure of extraction forceps, and no caries. All teeth were cleaned, washed, and stored in normal saline solution after extraction, prior to being used. A piece of.017.025 inch stainless steel wire was spot welded to a standard.018-inch stainless steel edgewise premolar mesh-backed bracket (Dentarum, Germany) along its vertical axis. One end of the wire was bent at a 90 degrees angle approximately 6 mm from the center of the bracket to make a handle for fixation on a metallic jig with the inner diameter of 25 mm. A thin line was scratched 4 mm from the center of the bracket on the opposite end of the wire, as a guide-line for mounting the teeth in their exact locations, parallel to the tip of the cusp. A New-Pipe tube was placed inside the jig and was filled with a cold cured acrylic (Acropars, Iran). The prepared wire was firmly fixed on the metallic jig with stick paper while carrying the bracket with its lingual surface facing the center of the jig (Fig. 1). Each tooth was inserted into the acrylic. At this point the scratched guide-line was parallel to the tip of the cusp. After the Fig.1: Mounting the index bracket on premolar teeth acrylic was set, the New-Pipe tube, now carrying the mounted tooth, was placed in normal saline solution. The enamel surface of each tooth was pumiced using a rubber cup in a contra-angle handpiece before being etched for 60 seconds with 37 percent phosphoric acid according to the manufacturer s instructions. The teeth were subsequently washed with 5cc distilled water, and air-dried with oil-free compressed air for 15 seconds. The etched area of the tooth and the base of the bracket were painted with a thin layer of primer. A no-mix chemical cured adhesive (Dentarum, Germany) was then placed on the base of the bracket, and the bracket was positioned using a 4-mm gauge. According to the information provided by the manufacturer, the setting time of the composite adhesive used in this study was 60 seconds therefore, the New-Pipe tube carrying each bonded specimen was set aside for 60 seconds and was secured in a metallic jig. Experimental de-bonding of brackets was carried out at intervals of 2, 5, 10, 15, 30, and 60 minutes in the first 6 groups; and 24 hours in the 7 th group, during which the teeth were kept in an incubator at 100% humidity and 37 o C temperature. An Instron Universal testing 2006; Vol. 3, No. 1 25

Journal of Dentistry, Tehran University of Medical Sciences Fig.: Setup of the experiment; path of force application machine (Instron Corp, model 8500, Canton, MA, USA) with a cylindrical cross-head diameter of 1.5 mm set at a speed of 5 mm/min, positioned perpendicular to the bracket (Fig 2) was used for the debonding procedure. The average surface area of the bracket base was determined to be 9.8 mm 2, using the shadowgraph technique [7]. The shear bond strength (MPa) at failure was measured for each specimen. The Kolmogorov-Smirnov test, one-way ANOVA and Duncan multiple range analyses were used for statistical analysis via SPSS software. RESULTS According to the Kolmogorov-Smirnov (α= 0.05) test, the data distribution was normal. The mean shear bond strength, standard deviation and standard error of each group are shown in Table I. The lowest and highest amounts of mean shear bond strength were 14.3 and 21.61 MPa, and encountered in the 1 st and 7 th groups respectively. One-way ANOVA showed a statistically significant difference between the mean shear bond strengths of the study groups (P<0.05). The Duncan multiple range test (Table II) revealed a significant difference between group 1 and the other groups (P<0.05). The shear bond strength increased significantly only in the 1st and 2nd groups, 5 minutes after bonding. The remaining groups did not show a significant increase (Fig. 3). DISCUSSION Shear bond strength of orthodontic composite adhesives depends on many variables such as: etch time, type of tooth, time of force application following bonding, the substrate used for storing the teeth, the temperature of the environment, the speed of mixing the two parts of the composite adhesive or the amount of each part, and the practitioner [9-12]. Table I: Descriptive statistics of mean shear bond strengths (in MPa), standard deviation (SD), minimum, and maximum for tested groups. 95% Group N Mean S.D. Min. Max. L.B U.B 2min 10 14.0310 2.03527 12.5751 15.4869 11.22 17.31 5min 10 19.5970 1.92817 18.2177 20.9763 14.97 21.52 10min 10 20.6740 1.89430 19.3189 22.0291 17.31 23.39 15min 10 21.1450 2.62741 19.2655 23.0245 16.38 24.80 30min 10 19.2720 2.54987 17.4479 21.0961 15.43 23.39 60min 10 20.5830 1.63075 19.4164 21.7496 17.33 22.45 24h 10 21.6190 3.00159 19.4718 23.7662 16.38 27.13 Total 70 19.5601 3.24791 17.9550 20.3334 11.22 27.13 26 2006; Vol. 3, No. 1

Force Application after Orthodontic Bonding orthodontic composite adhesive, measured in vitro, increased significantly (p<0.05) up to 5 minutes after the primary setting time. A slight but insignificant increase was also observed, up to 24 hours after bonding. A significant difference was encountered between the shear bond strength of the first group and the other groups but the difference was not significant in the remaining 6 groups. Reynolds [6] suggested that minimum bond strength of 5.9 to 7.8 MPa was adequate for most clinical orthodontic needs. The first group in the present study had the lowest shear bond strength (14.03 MPa), which was still below these optimal limits. Although the test conditions were similar in all groups, an insignificant decrease occurred in group 5 (the 30-minute group). The reason for this reduction is unclear but it may be related to the quality and the setting process of the tested material. Bishara et al [8] studied the effect of time on the shear bond strength of Fuji Ortho LC resinmodified glass ionomer and Transbond XT light-cure composite adhesives. Maxillary central incisor brackets were bonded to the buccal surfaces of freshly extracted human first molars. Their findings showed that the resin reinforced glass ionomer adhesive had significantly lower initial bond strength that increased more than 20-fold within 24 hours. Table II: Results of Duncan multiple range test. Group N 2min 10 14.0310 Subset for alpha = 0.05 1 2 3 30min 10 19.2720 5min 10 19.5970 19.5970 60min 10 20.5830 20.5830 10min 10 20.6740 20.6740 15min 10 21.1450 21.1450 24h 10 21.6190 P-value 1.000 0.107 0.081 Shear Bond Bond Strength Strength (MgP) (MPa) 25 20 15 10 5 0 14.03 19.59 20.67 21.14 19.27 20.58 21.61 2 min 5min 10min 15min 30 min 60 min 24hrs Time Fig. 3: The results of shear bond strength in different time intervals. In comparison, the composite adhesive had a significantly larger initial bond strength that doubled within 24 hours. These findings differ from the results obtained in the present investigation, which may be explained by the different materials and teeth used in the two studies. In a similar report, Bishara et al [9] compared the effect of time on the shear bond strength of Smart Bond cyanoacrylate and Transbond XT light cure composite adhesives. They found that with both materials the bond strength increased with time and that the bond strength was greater in the composite adhesive than the cyanoacrylate adhesive. Their findings indicated that the tested cyanoacrylate and composite adhesives had clinically adequate shear bond strengths at half an hour and 24 hours after initial bonding. According to the current investigation, the shear bond strength of the tested no-mix composite adhesive increased only in the first 5 minutes after bonding but there was no significant increase in bond strength afterwards until 24 hours post-bonding. Even 2 minutes after bonding, the shear bond strength was adequate for placing the initial arch wires. Chamda et al [10] compared the time-related bond strength of a light-cured (Transbond XT) and a chemically-cured (Concise) bonding system. They found the bond strength of the 2006; Vol. 3, No. 1 27

Journal of Dentistry, Tehran University of Medical Sciences chemically cured system to be initially low (up to 5 minutes after bonding), and of insufficient magnitude to withstand the immediate application of orthodontic forces. Their lightcured sample displayed initial bond strengths of sufficient magnitude to withstand the immediate application of orthodontic forces which increased with time. They did not find a significant difference between the bond strengths achieved by the chemically cured and light-cured systems at the 10-minute, 60- minute, and 24-hour intervals. This is in contrast to the results obtained in the present investigation; the bond strength of the studied chemically-cured composite adhesive (Dentarum) was of sufficient magnitude to withstand the immediate application of orthodontic forces, 2 minutes after bonding. Bin Abdullah [11] studied the effect of etch time and debond intervals on the shear bond strength of metallic orthodontic brackets bonded to maxillary first premolars with nomix Right On composite adhesive. They stated that an etch time of 30 seconds with 37% phosphoric acid would be necessary if the bracket was to be ligated within 5 minutes after bonding, but if it has been decided to apply the force 15 minutes after bonding, 15 seconds of etch time would be sufficient. Oslen et al [12] in another study recommend 20 to 30 seconds of etch time. In our study the teeth were etched for 60 seconds according to the manufacturer s instructions. Pickett et al [13] and Pecora et al [14] showed that the type of debonding device and crosshead also affect the results of bond strength analysis. Consequently an Instron Universal testing machine with a cylindrical cross-head has been recommended. An Instron Universal testing machine with a cylindrical cross-head (diameter=1.5 mm) set at a speed of 5 mm per minute was used in the present study. It is noteworthy that in vivo situations may be quite different from laboratory environments. Bishara et al [15] showed that thermocycling at 5 o C and 55 o C decreased the shear bond strength up to 80 percent as compared to brackets immersed in deionized water at 37 o C for 24 hours. It seems that the instability of the oral environment may affect the shear bond strength of orthodontic adhesives. According to Murray et al [16], brackets debonded after 4 weeks in vivo had significantly lower bond strengths (9.78 MPa) than did the controls (14.34 MPa) which were stored in sterile water at 37 o C. Pickett et al [13] also showed that mean bond strengths recorded in vivo following comprehensive orthodontic treatment are significantly lower than bond strengths recorded in vitro. In vivo, the bonding systems are exposed to numerous intraoral factors including saliva, acid, masticatory forces, variable patient abuse, and orthodontic mechanotherapy during the time period of comprehensive orthodontic treatment [13]. Therefore, it seems that postponing bracket ligation assuming that the bond strength of brackets will increase, as occurs in vitro, may not be a wise and logical decision. Tooth type was found to have a significant effect on bond strength [17]. Hobson et al [17] demonstrated that the minimum and maximum bond strength belongs to maxillary and mandibular molars, respectively. In the upper arch, bond strength was reported to be greater on anterior teeth than posterior teeth. The bond strength of maxillary first premolars, selected for the present study, falls somewhere in between. Therefore, regarding the results of the current study and findings by Reynolds [6], it can be concluded that 2 or at most 5 minutes after bonding, the initial bond strengths are of sufficient magnitude to withstand immediate application of orthodontic forces. CONCLUSION 1- The minimum shear bond strength (14.03 MPa) was encountered 2 minutes after the primary setting time of the composite adhesive. 28 2006; Vol. 3, No. 1

2- A significant difference was observed between the shear bond strengths of the 2- minute group and the other groups (P<.05). 3- The minimum shear bond strength of all groups was greater than the minimum shear bond strength necessary to withstand initial orthodontic forces. 4- The bracket and composite adhesive used in this study demonstrated initial bond strengths of sufficient magnitude to withstand the immediate application of orthodontic forces, i.e. 5.9-7.8 MPa, shortly (even 2 minutes) after the primary setting time. Therefore, the operator should not be concerned with bracket de-bonding due to primary arch wire placement during the first minutes after bracket set up or following rebonding a single bracket. ACKNOWLEDGMENTS: Authors would like to thank Mashhad University of Medical Sciences (MUMS), the Research Center, School of Dentistry, MUMS for their financial support, Radfarman Company for permission to use the Instron Machine and Mrs. Habibi M. for helping with the statistical analysis. REFERENCES 1- Buonocore MG. A simple method of increasing the adhesion of acrylic filling materials to enamel surface. J Dent Res 1955;34:849-53. 2- Zachrisson BU, Büyükyilmaz T. Bonding in orthodontics. In: Graber TM, Vanarsdall RL, Vig KW, editors. Orthodontics: Current principles and techniques. 4th ed. St Louis: Mosby; 2005. p. 557-645. 3- Linklater RA, Gordon PH. Bond failure patterns in vivo. Am J Orthod Dentofacial Orthop 2003; 123: 534-9. 4- Ireland AJ, Sherriff M. The effect of timing of archwire placement on in vivo bond failure. Br J Orthod 1997; 24: 243-45. 5- Adolfsson U, Larsson E, Ogaard B. Bond failure of a no-mix adhesive during orthodontic Force Application after Orthodontic Bonding treatment. Am J Orthod Dentofacial Orthop 2002; 122: 277-81. 6- Reynolds IR. A review of direct orthodontic bonding. Br J Orthod 1979; 2: 171-8. 7- Beer P. Mechanics of materials. 3rd ed. Boston: McGraw Hill; 1990. 8- Bishara SE, VonWald L, Olsen ME, Laffoon JF. Effect of time on the shear bond strength of glass ionomer and composite orthodontic adhesives. Am J Orthod Dentofacial Orthop 1999; 116: 616-20. 9- Bishara SE, Laffoon JF, VonWald L, Warren J. Effect of time on the shear bond strength of cyanoacrylate and composite orthodontic adhesives. Am J Orthod Dentofacial Orthop 2002; 121: 297-300. 10- Chamda RA, Stein E. Time-related bond strength of light-cured and chemically cured bonding systems: An in vitro study. Am J Orthod Dentofacial Orthop 1996; 110: 378-82. 11- Bin Abdullah M, Rock WP. The effect of etch time and debond interval upon the shear bond strength of metallic orthodontic brackets. Br J Orthod 1996; 23: 121-4. 12- Olsen ME, Bishara SE, Boyer DB, Jakobsen JR.. Effect of varying etching times on the bond strength of ceramic Brackets. Am J Orthod Dentofacial Orthop 1996; 109: 403-9. 13- Pickett KL, Sadowsky PL, Jacobson A, Lacefield W. Orthodontic in vivo bond strength: Comparison with in vitro results. Angle Orthod 2001; 71: 141-8. 14- Pecora N, Yaman P, Dennison J, Herrero A. Comparison of shear bond strength relative to two testing devices. J Prosthet Dent 2002; 88: 511-5. 15- Bishara SE, Ajlouni R, Laffoon JF. Effect of thermocycling on the shear bond strength of a cyanoacrylate orthodontic adhesive. Am J Orthod Dentofacial Orthop 2003; 123: 21-4. 16- Murray SD, Hobson RS. Comparison of in vivo and in vitro shear bond strength. Am J Orthod Dentofacial Orthop 2003; 123: 2-9. 17- Hobson RS, McCabe JF, Hogg SD. Bond strength to surface enamel for different tooth types. Dent Mater 2001; 17: 184-9. 2006; Vol. 3, No. 1 29