Quick start Prosthetics

Similar documents
NARROW DIAMETER implant

Straight Octagon Abutment for Tissue Level Implant

Blue Sky Bio Multi unit Abutments BIO Multi-Units are available for all our Bone Level Implants

SwissPlant Prosthetic Catalog. SwissPlant

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

» For multi-unit restorations -

User Manual Complete Prosthetic Kit (CPK)

4766 Research Dr. San Antonio, TX insightdentalsystems.com

Implant Phase Flow Chart

Osteotome inserts kit, angled. Impression tube (open tray) Selection abutment kit / Selection measurement post. Bar base PMMA & Finisher

CAD/CAM Prosthetic Solutions

ß For cement-retained crowns and bridges. Note: synocta cementable abutments. ß Can be especially helpful with large multi-unit cases Note:

QZ-Implant TRINON. Bone level implant with hexagonal internal cone connection

NEW NEW. An Extended Solution for Narrow Ridges

SIC invent. SIC P2F Abutment Dr. Galip Gurel From the gingiva shaper to a provisional crown to the final aesthetic restoration

» Prosthetic Options by MEDENTiKA «

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER

Legacy Prosthetic Catalog

PROSTHETIC EFFICIENCY. Straumann Angled Solutions (AS) Flexibility and precision from a different angle

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

SS Implant System 2013 PROSTHETIC PROCEDURE

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants

NobelParallel Conical Connection Product overview

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

Abutment level impression Ⅰ. Combi abutment/dual abutment Multi units

Element-Z Screw-Retained Hybrid

Xive. Product Catalog

UFII : Unique Fixture, 2 nd Generation. UFII Design Characteristics

InterActive System CONICAL. Prosthetic Catalog. simplycrown & bridge SMART PACK. InterActive All-in-1 Packaging simplyinteractive Mount-Free

Part 2: Internal Tri-Channel Connection. Nobel Biocare Compatible Components. Tri-Channel Internal Connection Implants

IQ IMPLANTS Smart Choice PRODUCT C ATA L O G

prosthetic technique manual

NARROW DIAMETER implant

SKY Titanium Implants

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix

- RESTORATIVE PRODUCT CATALOG

Including product catalog

Stock Prosthetic Guide 2014

US Implant System 2013 PROSTHETIC PROCEDURE

a perfect fit INSTRUCTION MANUAL CAMLOG TORQUE WRENCH WITH CONTINUOUS TORQUE ADJUSTMENT Handling Sterilization Care

ESTHETIC LINE implant

isy indications and techniques

HEXAGON Implant System

INDEX. Pag. 12. Pag. 05. Pag. 06. Pag. 13. Pag. 06. Pag. 14. Pag. 15. Pag. 15. Pag. 15. Pag. 15. Pag. 08. Pag. 16. Pag. 09. Pag.

Ø Smaller and Stronger.

STEP-BY-STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

NobelReplace Conical Connection Product overview

RePlant System Prosthetic Catalog

Ankylos. Product Catalog

Product Catalog 2017/2018. Straumann International Edition

STRAUMANN DENTAL IMPLANT SYSTEM RESToRATIVE SELECTION GUIDE

introduction to BioHorizons prosthetics

Step-by-Step Cemented Bridge Using Using CPK Abutments. Internal Hex. Implant System

The intelligent system.

Astra Tech Implant System. Manual and product catalog OsseoSpeed TX Profile

TRINON. Index. Index. Overview Page 4. Catalogue

T-SERIES. compatible to: DENTSPLY Implants / Xive. PLATFORM 3,4 mm 3,8 mm 4,5 mm 5,5 mm TITANIUM BASE SCAN BODY 3D-GUIDE LAB ANALOG IMPLANT PICK-UP

R-SERIES. compatible to: Zimmer Dental / Tapered Screw-Vent 36 NT-TRADING CATALOGUE PLATFORM 3,5 mm 4,5 mm 5,7 mm TITANIUM BASE

TS Implant System 2013 PROSTHETIC PROCEDURE

contents the smarter case approach reasons to choose simplyintegrated 5 system overview 6 ordering 7 mount-free implants 8-9

Solid Zirconia Full-Arch Implant Prosthesis (Protocol C All-CAD with Multi-Unit Abutments) BruxZir. FIRST Appointment. The BruxZir

simply simply digital simply crown & bridge simply removable simply fixed simply à la carte

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

cement-retained single crowns using cementable abutments

Restorative Manual July 2017

SCREW-RETAINED RESTORATION LINE. THE MULTI UNIT ABUTMENT SYSTEM ON STRAIGHT and tilted IMPLANTS

PRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable.

Product catalog. ASTRA TECH Implant System EV

Abutments for all indications. Individualized CAD/CAM and prefabricated implant restorations

IMPLANTS. Pearls. Your Precious Pearls. Made in Germany

Leading material offering and application range. Straumann CARES CADCAM

SwishPlant. SwishPlant System Catalog. 4.8mmD mmD. 4.8mmD mmD. 3.7mmD mmD. 6.5mmD

Locator retained mandibular complete prosthesis (isy Implant System)

E-SERIES. compatible to: Nobel Biocare / Replace Select. PLATFORM 3,5 mm NP 4,3 mm RP 5,0 mm WP 6,0 mm TITANIUM BASE SCAN BODY 3D-GUIDE LAB ANALOG

NEW. An Extended Solution. for Narrow Ridges

Multi-Unit Abutment Guide

STRAUMANN DENTAL IMPLANT SYSTEM RESToRATIVE SELECTION GUIDE

» QuattroFix treatment concept by MEDENTIKA «

S-SERIES. compatible to: DENTSPLY Implants / Astra Tech Implant System OsseoSpeed TX. PLATFORM 3,5 / 4,0 mm 4,5 / 5,0 mm TITANIUM BASE

The simple solution. One complete system. Tapered Screw-Vent Implant System Prosthetic Overview

Ankylos. Acuris conometric concept. Manual and product catalog

Bridging the Gap Between Original and Multi-Platform Systems.

NEW. An Extended Solution. for Narrow Ridges

Innovative Präzision Made in Germany

for individual milled Zirconium Abutment incl. screws Titanium Grade 5 ELI CAM CAM CAM CAM

OT EQUATOR CASTABLE Single Attachment for Overdentures

PART 6. Implant Prosthodontics

INSTRUCTIONS FOR USE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

INTRODUCTION. Why Choose Cortex Prosthetics?

Straumann Screw-retained Prosthetics

Implant And Abutment Level Impressions

Multi-unit abutment open tray technique using the direct pick-up coping

PRODUCT CATALOG 2014 CONELOG IMPLANTATSYSTEM PRODUCT PRODUKTKATALOG CATALOG 2014

Personal Attention Accurate Dental Solutions. Precision Down to the Smallest Detail. Wide Range of Dental Solutions Engineerd for a Lifetime

DECLARATION OF CONFORMITY To Council Directive 93/42/EEC of 14 June 1993

Prosthetic Guideline. Dental Implant System Tissue Level

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l

Ø Smaller and Stronger.

Transcription:

EN Quick start Prosthetics Easy and effective

YELLOW PROSTHETIC PLATFORM QN CEMENTED RESTORATIONS ESTHETIC AUTMENTS OPEN TRAY POST IMPLANT ANALOG Indexed components with internal conical connection. 0.7 mm 2170.07 1.5 mm 2170.15 3.0 mm 2170.30 /15 0.7 mm 2171.07 1.5 mm 2171.15 3.0 mm 2171.30 2715.00 2836.00 2841.00 Non-indexed components with internal conical connection. Abutments marked with this symbol are not suitable for single tooth restoration. SCREW-RETAINED RESTORATIONS IMPLANTS SCREW-ON AUTMENTS HEALING CAP COPINGS URN-OUT COPING AUTMENT ANALOG S2.9 10 mm 2003.10 12 mm 2003.12 14 mm 2003.14 16 mm 2003.16 1.0 mm 2177.01 2.0 mm 2177.02 3.0 mm 2177.03 4.0 mm 2177.04 2120.00 2710.00 2717.00 2811.00 2816.00 ATTACHMENT-RETAINED RESTORATIONS 2.0 mm 2166.02 4.0 mm 2166.04 6.0 mm 2166.06 LOCATOR ATTACHMENTS LOCATOR PROCESSING LOCATOR REPLACEMENT INSERTS COPING AUTMENT ANALOG PACKAGE 0.5 mm 02118 1.0 mm 02119 2.0 mm 02120 3.0 mm 02121 4.0 mm 02122 5.0 mm 02123 6.0 mm 02124 INDIVIDUAL PROSTHETIC SOLUTIONS 08519-2 blue 08529 red 08548 pink 08527 orange 08915 clear 08524 green 08547 08505 08530 2.0 mm 2167.02 4.0 mm 2167.04 6.0 mm 2167.06 LASAK CADCAM RIDGES AND AUTMENTS CAST-ON AUTMENT 2179.00 OPEN TRAY POST 2715.00 IMPLANT ANALOG 2836.00 2841.00 Tightening torque of gingiva former and impression components is 5 10 Ncm light finger force. Tightening torque of Screw-On bridge screw is 15 Ncm. Tightening torque of abutment screw, straight Screw-On abutments and LOCATOR attachments is 25 Ncm. If the torque of 50 Ncm is exceeded, by tightening the QN abutment screw, fracture will occure under the head of the screw. For tightening straight Screw-On abutments, use one of the insertion wrenches. Please, note that the insertion wrench mechanical, short is not suitable for tightening Screw-On abutments. The body of the Screw-On open tray (Ref. No. 2710.00) is manufactured from titanium and, together with the Screw-On bridge screw (Ref. No. 2106.00), can be used to create a Screw-On temp base for anchoring a temporary restoration.

LUE PROSTHETIC PLATFORM QR Indexed components with internal conical connection. Non-indexed components with internal conical connection. Abutments marked with this symbol are not suitable for single tooth restoration. ridge components with external platform. Abutments marked with this symbol are not suitable for single tooth restoration or linear anchored bridge. CEMENTED RESTORATIONS /15 0.7 mm 2138.07 1.5 mm 2138.15 3.0 mm 2138.30 ESTHETIC AUTMENTS CERAMIC AUTMENTS TEMPORARY AUTMENTS d5.0 d5.0 d4.0 0.7 mm 2137.07 1.5 mm 2137.15 3.0 mm 2137.30 /25 0.7 mm 2139.07 1.5 mm 2139.15 3.0 mm 2139.30 /15 0.7 mm 2141.07 1.5 mm 2141.15 3.0 mm 2141.30 0.7 mm 2140.07 1.5 mm 2140.15 3.0 mm 2140.30 /25 0.7 mm 2143.07 1.5 mm 2143.15 3.0 mm 2143.30 STANDARD AUTMENTS 1.0 mm 2133.01 2.0 mm 2133.02 3.0 mm 2133.03 4.0 mm 2133.04 0.7 mm 2146.07 2.5 mm 2146.25 d5.0/15 0.7 mm 2147.07 2.5 mm 2147.25 1.0 mm 2127.01 3.0 mm 2127.03 d4.0 1.0 mm 2128.01 3.0 mm 2128.03 POSTS 2704.00 2705.00 2708.00 IMPLANT ANALOG 2803.00 2833.00 IMPLANTS S3.5 8.0 mm 2006.08 10 mm 2006.10 12 mm 2006.12 14 mm 2006.14 16 mm 2006.16 T4.0 8.0 mm 2012.08 10 mm 2012.10 12 mm 2012.12 14 mm 2012.14 16 mm 2012.16 S4.0 6.5 mm 2009.06 8.0 mm 2009.08 10 mm 2009.10 12 mm 2009.12 14 mm 2009.14 16 mm 2009.16 d4.2 2.0 mm 2109.02 4.0 mm 2109.04 6.0 mm 2109.06 2.0 mm 2110.02 4.0 mm 2110.04 6.0 mm 2110.06 SCREW-RETAINED RESTORATIONS SCREW-ON AUTMENTS /20 /30 1.0 mm 2148.01 2.0 mm 2148.02 3.0 mm 2148.03 4.0 mm 2148.04 ATTACHMENT-RETAINED RESTORATIONS LOCATOR ATTACHMENTS LOCATOR PROCESSING LOCATOR REPLACEMENT INSERTS COPING AUTMENT ANALOG PACKAGE 0.5 mm 01284 1.0 mm 01285 2.0 mm 01286 3.0 mm 01287 4.0 mm 01288 5.0 mm 01289 6.0 mm 01290 3.0 mm 2149.03 4.0 mm 2149.04 5.0 mm 2149.05 4.0 mm 2150.04 5.0 mm 2150.05 08519-2 HEALING CAP blue 08529 red 08548 2120.00 pink 08527 orange 08915 COPINGS URN-OUT COPING AUTMENT ANALOG 2710.00 2717.00 clear 08524 green 08547 2811.00 2816.00 08505 08530 T5.0 8.0 mm 2020.08 10 mm 2020.10 12 mm 2020.12 14 mm 2020.14 S5.0 6.5 mm 2017.06 8.0 mm 2017.08 10 mm 2017.10 12 mm 2017.12 14 mm 2017.14 ridge d4.9 2.0 mm 2116.02 4.0 mm 2116.04 6.0 mm 2116.06 INDIVIDUAL PROSTHETIC SOLUTIONS LASAK CADCAM RIDGES AND AUTMENTS CAST-ON AUTMENT TEMPORARY AUTMENTS POSTS IMPLANT ANALOG 2154.00 d4.0 d4.0 1.0 mm 2127.01 3.0 mm 2127.03 1.0 mm 2128.01 3.0 mm 2128.03 2704.00 2705.00 2708.00 2803.00 2833.00 Tightening torque of gingiva former and impression components is 5 10 Ncm light finger force. Tightening torque of Screw-On bridge screw is 15 Ncm. Tightening torque of abutment screw, ceramic abutment screw, straight Screw-On abutments and LOCATOR attachments is 25 Ncm. For tightening straight Screw-On abutments, use one of the insertion wrenches. Please, note that the insertion wrench mechanical, short is not suitable for tightening Screw-On abutments. The body of the Screw-On open tray (Ref. No. 2710.00) is manufactured from titanium and, together with the Screw-On bridge screw (Ref. No. 2106.00), can be used to create a Screw-On temp base for anchoring a temporary restoration.

QN impression components overview QR impression components overview AUTMENTS OPEN TRAY CLOSED TRAY AUTMENTS OPEN TRAY CLOSED TRAY Esthetic narrow /15 Esthetic narrow /15 /25 d4.2 Closed tray Attachments LOCATOR LOCATOR Attachments LOCATOR Screw-On /20 /30 Screw-On open tray Screw-On closed tray LOCATOR STANDARD staight, wide d5.0 STANDARD Screw-On straight Screw-On open tray Screw-On closed tray Esthetic wide /15 /25 Ceramic wide Cast-On Cast-On d5.0 d5.0/15 LASAK CadCam custom abutment Closed tray LASAK CadCam custom abutment Temporary d4.0 LASAK CadCam bridges LASAK CadCam bridges ridge d4.9 impression post bridge Temporary bridge d4.0

Recommendations Multi-unit superstructures Multi-unit screw-retained superstructures can be made either by using Screw-On abutments or as milled implant-supported LASAK CadCam superstructures. For LASAK CadCam superstructures, use the bridge components marked (bridge). Using bridge gingiva formers, s and temporary abutments allows for optimum soft tissue management and the precise fit of the restoration to the implant surface. The same is true for restorations made with the bridge Cast-On abutments. ridge abutments are not suitable for linear anchored bridges. Turning the indexed component When inserting the implant, ensure to orientate the flat part of the internal hexagon in the vestibular direction to obtain the maximum esthetic effect. efore tightening the pin, make sure the fits well in the internal hexagon of the implant. Tighten the pin with a screwdriver. If in doubt, use OPG to check the situation. The fastening pin can be shortened by 3.5 mm, if necessary. There is a ring marked on the pin where it can be broken with the help of a screwdriver. The body of the can be shortened with a se paration disc. Warning! The body of and the pin can only be shortened extraorally. 3.5 mm LASAK Ltd. Českobrodská 1047/46 190 01 Prague 9 Hloubětín Czech Republic tel.: +420 224 315 663 fax: +420 224 319 716 e-mail: info@lasak.com www.lasak.com