T.Kanai, K. Yusa, M. Tashiro, H. Shimada, K. Torikai, Gunma University, Gunma, Japan

Similar documents
New Treatment Research Facility Project at HIMAC

Review of Hadron machines for cancer therapy

Review of Heavy Ion Accelerators for Hadrontherapy

Heavy Ion Tumor Therapy

Progress of Heavy Ion Therapy

SUMITOMO Particle Therapy Technologies

Radiation qualities in carbon-ion radiotherapy at NIRS/HIMAC

Nuclear Data for Radiation Therapy

Cancer Treatment by Charged Particles - Carbon Ion Radiotherapy -

*Chien-Yi Yeh, Ji-Hong Hong * 葉健一洪志宏

Technical approach to individualized respiratory-gated carbon-ion therapy for mobile organs

Characterization and implementation of Pencil Beam Scanning proton therapy techniques: from spot scanning to continuous scanning

Proton and heavy ion radiotherapy: Effect of LET

8/1/2016. Motion Management for Proton Lung SBRT. Outline. Protons and motion. Protons and Motion. Proton lung SBRT Future directions

Learning Objectives. Clinically operating proton therapy facilities. Overview of Quality Assurance in Proton Therapy. Omar Zeidan

The Advantages of Particle Therapy and the Status of the Heidelberg Iontherapy Center

HIMAC AND MEDICAL ACCELERATOR PROJECTS IN JAPAN

Hampton University Proton Therapy Institute

The Heidelberg Ion Therapy Center and PARTNER. Thomas Haberer Heidelberg Ion Therapy Center

PTCOG 46. Educational Workshop Session IV. Head & Neck CLINICAL. J. Mizoe (NIRS, Japan)

Biological Optimization of Hadrontherapy. Uwe Oelfke

Intensity Modulated RadioTherapy

Particle Therapy Systems by Mitsubishi Electric DG1101-KM-0034

Treatment Planning (Protons vs. Photons)

Practical Challenges and Opportunities for Proton Beam Therapy. M. F. Moyers Loma Linda University Medical Center

Discuss the general planning concepts used in proton planning. Review the unique handling of CTV / ITV / PTV when treating with protons

Proton Beam Therapy at Mayo Clinic

Ion Beam Therapy should we prioritise research on helium beams?

ABSTRACTS. of the NIRS International Seminar on the Heavy Charged Particle Therapy for Cancer and the XXVII PTCOG MEETING.

The Heidelberg Ion Therapy Center. Thomas Haberer Heidelberg Ion Therapy Center Hadron Therapy Workshop, Erice 2009

Proton and helium beams: the present and the future of light ion beam therapy

IN VIVO IMAGING Proton Beam Range Verification With PET/CT

Peak temperature ratio of TLD glow curves to investigate the spatial variation of LET in a clinical proton beam

Image Guided Stereotactic Radiotherapy of the Lung

Leila E. A. Nichol Royal Surrey County Hospital

A brief presentation of The TERA Foundation

Proton Treatment. Keith Brown, Ph.D., CHP. Associate Director, Radiation Safety University of Pennsylvania

Advances in external beam radiotherapy

Present status and future of Proton beam therapy

Proton Therapy Dosimetry & Clinical Implementation. Baldev Patyal, Ph.D., Chief Medical Physicist Department of Radiation Medicine

III. Proton-therapytherapy. Rome SB - 5/5 1

Figure 1.1 PHITS geometry for PTB irradiations with: broad beam, upper panel; mono energetic beams, lower panel. Pictures of the setups and of the

FROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE. Geoffrey S. Ibbott, Ph.D. June 20, 2017

EORTC Member Facility Questionnaire

Protons Monte Carlo water-equivalence study of two PRESAGE formulations for proton beam dosimetry J. Phys.: Conf. Ser.

MVCT Image. Robert Staton, PhD DABR. MD Anderson Cancer Center Orlando. ACMP Annual Meeting 2011

ADVANCES IN RADIATION TECHNOLOGIES IN THE TREATMENT OF CANCER

Non-target dose from radiotherapy: Magnitude, Evaluation, and Impact. Stephen F. Kry, Ph.D., D.ABR.

The Heidelberg Ion Therapy (HIT) Accelerator Coming Into Operation. Presented at EPAC 2008, Genova D. Ondreka, GSI

Status of H 1 and C 12

PRESCRIBING RECORDING AND REPORTING PROTON BEAM THERAPY ICRU 78. RAJESH THIYAGARAJAN Senior Medical Physicist & RSO Medanta The Medicity

arxiv: v1 [physics.med-ph] 31 Oct 2017

OPERATION AND PATIENT TREATMENTS AT CNAO FACILITY

Clinical Report for Wanjie Proton Therapy Center. Li Jiamin, MD Wanjie Proton Therapy Center

Application of Implanted Markers in Proton Therapy. Course Outline. McLaren Proton Therapy Center Karmanos Cancer Institute McLaren - Flint

Prof. Dr. Thomas Haberer Scientific-technical Director Heidelberg Iontherapy Center

Electron therapy Class 3: Clinical procedures

Production and dosimetry of simultaneous therapeutic photons and electrons beam by linear accelerator: a monte carlo study

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

The Physics of Oesophageal Cancer Radiotherapy

Topics covered 7/21/2014. Radiation Dosimetry for Proton Therapy

Uncertainties in proton therapy: Analysis of the effects of density changes, calibration curve errors and setup errors in proton dose distributions.

Variable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10

Application of the Multi-Model Monte-Carlo Treatment Planning System Combined with PHITS to Proton Radiotherapy

6/29/2012 WHAT IS IN THIS PRESENTATION? MANAGEMENT OF PRIMARY DEVICES INVESTIGATED MAJOR ISSUES WITH CARDIAC DEVICES AND FROM MED PHYS LISTSERVS

IMPT with Carbon Ions

Stereotactic Body Radiotherapy for Lung Lesions using the CyberKnife of-the-art and New Innovations

4D Radiotherapy in early ca Lung. Prof. Manoj Gupta Dept of Radiotherapy & oncology I.G.Medical College Shimla

Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, Pamela Myers, Ph.D.

H. Röcken, M. Abdel-Bary, E. Akcöltekin, P. Budz, T. Stephani, J. Wittschen

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

PHYS 383: Applications of physics in medicine (offered at the University of Waterloo from Jan 2015)

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Assessing Heterogeneity Correction Algorithms Using the Radiological Physics Center Anthropomorphic Thorax Phantom

An introduction to medical imaging and radiotherapy: Current status and future directions I

THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS

Andrew K. Lee, MD, MPH Associate Professor Department tof fradiation Oncology M.D. Anderson Cancer Center

4 Essentials of CK Physics 8/2/2012. SRS using the CyberKnife. Disclaimer/Conflict of Interest

Herlev radiation oncology team explains what MRI can bring

Introduction to Ion Beam Cancer Therapy

The Journey of Cyberknife Commissioning

Transition to Heterogeneity Corrections. Why have accurate dose algorithms?

Treatment Efficiency and Optimization of Patient Care with IBA ProteusOne

Helical Tomotherapy Experience. TomoTherapy Whole Brain Head & Neck Prostate Lung Summary. HI-ART TomoTherapy System. HI-ART TomoTherapy System

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

PROGRESS IN HADRONTHERAPY

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

State-of-the-art proton therapy: The physicist s perspective

Summary of Synchrotron for Hadron Therapy

Therapeutic Medical Physics. Stephen J. Amadon Jr., Ph.D., DABR

Considerations when treating lung cancer with passive scatter or active scanning proton therapy

Proton Stereotactic Radiotherapy: Clinical Overview. Brian Winey, Ph.D. Physicist, MGH Assistant Professor, HMS

Workshop on Hadron Beam Therapy of Cancer Erice, Sicily April 24-May

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

La ricerca e la terapia in adroterapia-2. R.Orecchia / P. Fossati

S. Derreumaux (IRSN) Accidents in radiation therapy in France: causes, consequences and lessons learned

Feasibility of 4D IMRT Delivery for Hypofractionated High Dose Partial Prostate Treatments

Activities at the Heidelberg Ion Therapy Center (HIT)

Proton Therapy for Prostate Cancer. Andrew K. Lee, MD, MPH Director Proton Therapy Center

Transcription:

The carbon-ion cancer therapy facility at Gunma University T.Kanai, K. Yusa, M. Tashiro, H. Shimada, K. Torikai, J. Koya, T. Ishii, Y. Yoshida, S. Yamada, T. Ohno, T. Nakano Gunma University, Gunma, Japan

Content 1. Introduction 2. Accelerator System 3. Design of SOBP 4. Treatment Planning System 5. Clinical experiences 6. Treatment of Moving Targets

1. Introduction

GHMC Main Features Facility at Gunma Heavy-ion Medical Center (GHMC) is an outcome of the NIRS R&D Program for a compact carbon facility (2001 2005). Compact high-performance linac injector Compact synchrotron lattice Spiral wobbling Layer stacking System Treatment planning system

Schedule - 2006 2007 2008 2009 2010 2011 R&D at NIRS Engineering and Physics design Contract Jan. 2007 Manuf. Design and Fabrication Installation and Testing Beam Test Clinical Comm. 12 1 st Treatment March 16 th 2010 80 pts Advanced medical technology Scanning Port 1~3 Restart of treatment

GHMC Gunma University 3 treatment rooms, 4 beam lines A: Horizontal BL B: Horizontal + Vertical BL C: Vertical BL D: R & D for scanning

More compact! Less expensive! NIRS (1994-) 120m 65m Gunma University (2010-) 2001 Concept of the project 2004 Start Collaborations with NIRS 135,000,000 USD 45m HIMAC 1/3 cost/size GHMC 65m

2. Accelerator System

GHMC Specifications Ion type Energy Maximum range SOBP Maximum aperture Lateral field shaping Beam intensity Dose rate Beam delivery modes :Carbon :140 400 MeV/u :25 cm :2 14 cm (with ridge filters) :15 cm x 15 cm :Single radius wobbling Spiral wobbling :1.3 x 10 9 pps (3 sec cycle) @treatment nozzle :5 GyE/min for φ15 cm 10 cm SOBP :Respiration gating Layer Stacking

Accelerator System 66.0m C 6+ 400 MeV/u max 1.3 x 10 9 pps 38.4m Synchrotron Extraction RF Cavity ECR C 4+ RFQ APF-IH C 4+ Foil C 6+ 4 MeV/u Injector

Injector Linac

Synchrotron

HEBT Line

Generate and accelerate C 4+ Convert to C 6+ by stripping foil ECR Ion Source Injector Linac Plenty of beam > 300 eµa C 6+ at injector exit after stripping No HV deck! RFQ Linac Optimized for C 4+ APF-IH Linac E-field focusing No magnets! Highly efficient RF power 1.3 MW 0.5 MW Stable operation ECR (10 kev/u) No HV Deck! RFQ (0.6 MeV/u) 10.6 m 6.2 m APF-IH (4.03 MeV/ u ) Extensive E, B field calculations! Manufactured by SHI

Synchrotron Compact lattice by NIRS (modified FODO) Advanced beam simulation code Know-how to achieve the design beam current Slow extraction process (MELCO process) Features Main dipoles are almost rectangular Very low-noise power supplies Wide-band (non-resonant) RF accelerating cavities Very stable and reproducible system No daily tuning is needed Synchrotron: main parameters Circumference m 63.3 Dipole field T 0.134~1.477 Momentum compaction factor Long straight section m 3.1 Ion C(6+) Injection energy MeV/u 4 Extraction energy MeV/u 140~400 Number of particles pps 1.3 x 10 9 Cycling period sec > 3 Accelerating RF frequency MHz 0.875~6.769 Harmonic number 2 Max. RF voltage kv 2 0.3241~0.3429

Synchrotron Commissioning 24 Aug. 2009 Start of synchrotron commissioning 25 Aug. 2009 Acceleration up to 400 MeV/u 30 Aug. 2009 First extraction 5 Sep. 2009 First beam transported to treatment room-a 30 Sep. 2009 Beam transport to all treatment rooms 26 Dec. 2009 Beam transport at all scheduled energies Beam commissioning was conducted in a very short period. Commissioning is based on a systematic use of computer modeling, magnetic field data and beam measurements. And a thorough understanding of the dynamics. Circulating beam current 1 sec Beam spill Computer model Magnetic field measurement (factory data) Systematic beam measurement data Operating parameters Building is also an important part of the performance

Synchrotron Commissioning 0.4 sec 1.8 sec Beam gate Beam spill Beam is turned on/off for respiration gating Beam extraction timing is variable for each pulse Circulating beam current Beam gate 0.4 s/div Multiple beam on/off per pulse Beam shut-off time < 1ms Beam spill

Treatment Beam Lines 3 treatment rooms, 4 beam lines A: Horizontal B: Horizontal + Vertical C: Vertical 13 3.8m Beam monitors Wobbler magnets scanning speed 57Hz ~50 mm/msec at isocenter Ridge filters, Range shifters Flatness monitors, X-ray tube MLC 3.75mm leaf pitch 40 pairs X-ray DR 2 orthogonal views Treatment Room B

Spiral Wobbling * Advantages compared to the conventional broad beam methods Smaller range loss due to thinner scattering foil More homogeneous lateral distribution Higher beam utilization efficiency Yg [mm] 200 150 100 50 Wobbling Time :20ms Yg [mm] 200 150 100 50 Wobbling Time :200ms Yg [mm] 200 150 100 50 Wobbling Time :1000ms Fast wobbling magnets Pencil beam: σ=2.5cm 0 0 0-50 -50-50 -100-100 -100 Relative Dose -150-200 -200-150 -100-50 0 50 100 150 200 Xg [mm] 3.00E+00 Wobbling Time : 20ms 2.50E+00 2.00E+00 1.50E+00 1.00E+00 5.00E-01 0.00E+00-250 -200-150 -100-50 0 50 100 150 200 250 Lateral Position Xg [mm] Relative Dose -150-200 -200-150 -100-50 0 50 100 150 200 Xg [mm] 1.20E+01 Wobbling Time : 200ms 1.00E+01 8.00E+00 6.00E+00 4.00E+00 2.00E+00 0.00E+00-250 -200-150 -100-50 0 50 100 150 200 250 Lateral Position Xg [mm] Relative Dose -150-200 -200-150 -100-50 0 50 100 150 200 Xg [mm] 6.00E+01 5.00E+01 4.00E+01 3.00E+01 2.00E+01 1.00E+01 Wobbling Time : 1000ms 0.00E+00-250 -200-150 -100-50 0 50 100 150 200 250 Lateral Position Xg [mm] Testing has been completed. Preparing for the Government medical approval process. * Optimization of Spiral-Wobbler System for Heavy-Ion Radiotherapy, M. KOMORI, T.FURUKAWA, T.KANAI, K. NODA Journal Title;Jpn J Appl Phys Part 1, VOL.43;NO.9A; pp6463-6467 (2004).

Stacked-Layer Conformal Treatment Kanai et al., Med. Phys. 10, 344-346 (1983) Longitudinally divide the target slices Conform thin layer of SOBP (mini-peak) to each slice variable SOBP Bolus is used to form the distal layer Multi-Leaf Collimator is used to form the proximal part of the target beam Testing to be completed in 2011. 5mm pitch

3. Design of SOBP

NIRS method for SOBP design Assumption 1 (pragmatic approach) HSG cell represents all of tumor cell 6 350 MeV/u; SOBP 60mm 10 5 8 RBE=1 4 Clinical 6 13.3 kev/µ m 3 Biological 4 2 Physical 77keV/µ m 2 1 0 0 2 4 6 8 10 D 10 for X-rays (Gy) 0 0 50 100 150 200 250 Depth in Water (mm)

SOBP RBE for Neutron therapy Photon _ Eq. D( z) (GyE) = = ( scaling ( scaling _ factor) RBE _ factor) RBE HSG HSG RBE at SOBP center ( d, z) d SOBP ( z) d ( d, center) HSG SOBP HSG dsobp ( s, center) d ( s, z) Bio. Response relative to SOBP center SOBP ( z) Fix to survival level of 10 % GyE (NIRS) HSG HSG d X (0.1) dsobp (0.1; center) 1.45 dsobp ( z) HSG HSG d (0.1; center) d (0.1; z) SOBP SOBP

Dose dependence of the biological response relative to SOBP center d HSG SOBP HSG dsobp ( s, center) ( s, z) 1.5 z d HSG SOBP HSG dsobp (0.1; center) (0.1; z) 1.4 1.3 1.2 1.1 1 0.9 +25 mm +20 mm +10 mm 0 mm -10 mm -20 mm -25 mm Except very near the distal part of the SOBP, the variation is small. 0.8 2 3 4 5 6 7 Physical Dose at Center of SOBP = d HSG of reference carbon beam(gy) SOBP (center)

Variation of sensitivity estimated by TCP analysis. TCP = exp N i 1 exp 2π α exp nαd ( α i α ) 2( α ) d 0.693 ( ) ( T T k ) 1 + + α / β Fixed Parameters 2 2 T p α=0.75,β=0.076, α=0.15, T k =0, T p =7 1 tentative 1.2 TCP can be analyzed by LQ model introducing the variation of the sensitivity α, α. 1 0.8 TCP for Non Small Cell Lung Cancer Optimal Dose 25.2 Gy (60 Gy (CRx); T2) 22.2 Gy (52.8 Gy (CRx); T1) O ptim al D ose 30.25 Gy (72 Gy (CRx)) ~95% TCP 0.8 0.6 4 Frac. 9 Frac. 0.6 4Fx 9Fx 0.4 0.4 18Fx 0.2 1Fx 0.2 0 0 20 40 60 80 100 Physica l Dose (Gy) 0 0 5 10 15 20 25 30 35 40 Total Physical Dose at center of SOBP 60 mm(gy)

Biological uncertainties: We have to introduce variation in radiation sensitivity, (α± α) in TCP analysis with LQ model. There will be large uncertainty for survival fractions below 0.001. d 1.2 +5% 1-5% 0.8 ( s; center) ( s; z) HSG SOBP HSG dsobp d d SOBP 350 MeV/u, SOBP 60mm ( z) ( center) SOBP Biological dose distribution used in TPS is in the uncertainty region of tumor responses (α± α) for various fractionation size. 0.6 0.4 0.2 0 4F 9F 12F 16F α+0.15 α-0.15 16F 12F 9F 4F alpha-0.15 alpha+0.15 0 50 100 150 200 250 Depth in Water (mm)

At present stage of carbon therapy It can be justified to use fixed SOBP for various fractionation size. Detail analysis of carbon clinical trial should be required in order to step further. Tumor responses and normal tissue responses

Physical Aspect of SOBP Design LET distribution in water phantom should be taken into account for SOBP design Fragmentations produced by aluminum ridge filter should be taken into account. C 290 M ono-energy m easured by 0.2 m m P lastic S cintillator 4000 6 Ridge Filter Design Shift 3500 5 3000 2500 2000 4 3 Aluminium (Ridge Filter) 1500 1000 500 2 1 0 0 100 200 300 400 500 600 C hanneln um ber 0-100 -50 0 50 100 150 200 Depth in Water (mm)

Measurements of PDD Depth dose distributions; 350 MeV/n Roos Chamber 6 10-12 5 10 4 Monte 350 MeV/n; Geant4 Pencil Beam Calro 5 10-12 4 10 4 4 10-12 3 10-12 Al0mm2 Al10mm Al20mm Al30mm Al40mm Al50mm Al60mm 3 10 4 2 10 4 total total-10mm total-20mm total-30mm total-40mm total-60mm 2 10-12 1 10-12 1 10 4 0 0 50 100 150 200 250 300 Depth in Water (mm) 0 0 50 100 150 200 250 300 Depth in Water(mm) Aluminum plate @ Ridge Filter Position isocenter Wobbler M. SAD 15x15cm: Full Open 20cm water We adjusted fragmentation yield.

Physics to biology 3.5 LQ model parameter, α and β 3 2.5 OER (He) OER (C) a(hsg)forc b(hsg)forc a(hsg)forhe b(hsg)forhe OER(HSG)forC OER(HSG)forHe 2 1.5 α (He) All fragmented particles are assumend to be alpha particles 1 α (C) 0.5 0 1 10 100 1000 LET (kev/µm) β

5 Phys.Dose(350) Bio.Dose(350) Phys.Dose(380) Bio.Dose(380) 4Phys.Dose (290) Bio.Dose (290) SOBP 80, 290,350,380 MeV/n 3 2 1 @ SOBP Center E Phys.D Bio.D 290 2.55 4.034 350 2.60 4.033 380 2.63 4.035 0 0 20 40 60 80 100 120 140 160 Depth in Water (mm)

1 Survival Fraction of HSG cells (for carbon 350 MeV/n, SOBP 80 mm beam) Survival curve of HSG cells in GHMC (350 MeV/n, SOBP 80 mm) Surviving Fraction Surviving Fraction [%] 0.1 0.1 0.01 0-30 mm +30 mm Center Proximal Distal 0.001-1 0 1 2 3 4 5 6 Physical Dose (at different Dose [Gy] SOBP points) [Gy]

4. Treatment Planning System, Xio-N

System structure Treatment Planning plat form (Xio) XiO-N system Dose calculation code Connection software Calc. Engine K2Dose System Data DICOM-ION Server

Specification in calculation Pencil Beam algorithm Heavy-ion specific modeling QA Plan Planning for new wobbling methods Single Circle Conventional wobbling Layerstacking Spiral wobbling

Pencil beam method Algorithms - Broad beam downstream of aperture is divided small gauss shape beams which are transported through the inhomogeneous structure - Scattering at each thickness of ridge filter is also considered - Dose at a grid is summed up and distribution results in couple of minutes

Heavy Ion specific modeling RBE modeling -From LET (or depth) dependence of α & β of LQ model, clinical dose distributions are calculated so as to give 10 % survival level of HSG cell at the center of the SOBP. β[gy -2 ] α[gy -1 ] Range[mmH 2 O] HSG d X (0.1) GyE( NIRS) = 1.45 dsobp ( z) HSG d (0.1; z) SOBP

QA Plan TPS for patients TPS for QA Plan Comparison Measure Dose distributions in water phantom

Beam Modeling Check SAD check Lateral penumbra dependence -Degrader thickness -Collimator position etc.

Dose calculation check 1.5 distal-xion SOBPcenter-XioN proximal-xion DistalC380SOBP80-PinPoint CenterC380SOBP80-PinPoint ProximalC380SOBP80-PinPoint C380SOBP80-PinPoint XioN 1 0.9 0.8 Relative Dose 1 0.5 Relative Dose 0.7 0.6 0.5 0.4 0.3 0.2 0-60 -40-20 0 20 40 60 Lateral (mm) 0 40 80 120 160 200 240 280 depth (mm)

Dose distribution check Check using QA Phantom and QA plan 41

5. Clinical Experiences

Initiation of the clinical protocols at Gunma University Many of phase I/II dose escalation and phase II studies for various tumor sites have been carried out at NIRS since 1994. Although promising clinical outcomes have been reported from NIRS, it is of interest whether the efficacy of carbon ion radiotherapy from a single institution can be reproduced in other facilities when optimal doses and fractionations are used for a similar patient population. At GHMC, the efficacy and safety of carbon ion radiotherapy were reviewed for each tumor type, and then the currently best available dose and fractionation schedules determined at NIRS were adopted for our clinical protocols.

Dose & fractionation at Gunma University Sites Total dose (GyE) Fractionation (Fr) Duration (Week) Head & Neck 64 16 4 Lung (stage I) 52.8 or 60 4 1 Liver 52.8 4 1 Prostate 57.6 16 4 Sarcoma 64 or 70.4 16 4 Rectum (pelvic rec.) 73.6 16 4

Clinical schedule at Gunma University In 2010, 92 patients have been treated (10-15 patients per day). 2010.March 2010.June 2010.June 2010.July 2010.September 2010.September Prostate Lung (stage I peripheral type) Head & Neck cancer (non-squamous) Hepatocellar carcinoma Pelvic recurrence of rectal cancer Bone & Soft tissue sarcoma

6. Moving Target

Strategy for Mobile Organs Use of 4D-CT Definition of margins (PTV) for each patient Confirmation of dose distributions in the gating period (Gate-In, Exhale Peak, Gate-Out) Range Compensator (Bolus) design Smearing and/or IGTV (GTV + IM) methods To do the above, we utilize our present systems for routines. (Xio-N, Focal4D)

Picture of Lung Treatment (Gating) Respiration (Respiratory Wave) Beam Beam Beam Beam Motion of the skin at thoraco-abdomen is monitored by a laser sensor as respiration (respiratory wave), and carbon-ion beam is irradiated at the gated timing corresponding to the exhalation.

Picture of Lung Treatment(4 Ports) Roll +20 Roll -20

Treatment Flow CT Simulation Room Acquire Resp. Wave Treatment Planning Room Gated CT 4D-CT X-ray Fluoroscopy Temporal TP (Temp. Iso-Center ) Gated X-ray (Reference images for daily setup) (This can be done after TP approved as Rehearsal. ) Definition of IM (Focal 4D) Treatment Planning (Xio-N) Irradiation Room Positioning using X-ray images (Confirm reproducibility) Gated Irradiation

Treatment Planning Target Volume Definition (Lung) GTV IGTV PTV 8mm CTV IM+SM (each direction) Bolus Design Smearing method Smearing = TM (Perpendicular to beam) CTV = GTV + 8mm (exclude the outside of lung) PTV = CTV + TM Total Margin 2 TM = IM + SM In case of IGTV method (SM = 3mm) After PTV was made GTV is extended IGTV = GTV + IM (force CT=1 for IM region) From the measured motion at 0-30%Lv, 1/3 of the motion is added for IMs. Beam TM 2 Smearing method IGTV method IGTV(GTV + IM) ForceCT = 1 (tumor value) Smearing = SM After bolus design, the IGTV CT value is returned to the original (raw CT values). Beam IGTV method IGTV=GTV+IM

Treatment Plan (Lung) 52.8GyE/4Frac

Smearing & IGTV Smearing method (1) IGTV method (2) (1) - (2)

Dosimetric Validation QA Plan 1,8E-04 1,6E-04 1,8E-04 1,6E-04 Plan1Beam2 Z=80mm Plan2Beam1 z=60mm Plan2Beam1 z=50mm 1,4E-04 1,4E-04 Dose (Gy/Count) 1,2E-04 1,0E-04 8,0E-05 6,0E-05 Dose (Gy/Count) 1,2E-04 1,0E-04 8,0E-05 6,0E-05 4,0E-05 2,0E-05 0,0E+00 Plan1Beam2 Plan2Beam1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Depth (cm) 4,0E-05 2,0E-05 0,0E+00-5 -4-3 -2-1 0 1 2 3 4 5 Off Center (cm)

Analysis of Patient Positioning From the values of the differences, set-up errors (positioning) and internal motion errors are evaluated for the validation of our strategy of margins & TP.

Error Distributions of Interest Points (7 Lung Pat.) 70 12 60 10 50 40 30 20 10 X Y Z Y 8 6 4 2 X Y Z Y 0 5 4 4 3 3 2 2 1 1 0 0 - -1 - -2 - -3 - -4 - -5 (mm) 0 10 9 8 7 6 5 4 3 2 1 0-1 -2-3 -4-5 -6-7 -8-9 -10-11 (mm) Set-up Errors (Positioning) Errors of Metal Markers (Internal Motion Errors) Frontal Lateral Frontal Lateral X(LR) Y(SI) Z(AP) Y(SI) Y All X(LR) Y(SI) Z(AP) Y(SI) Y All Average 0.011972-0.02787 0.00061 0.004902-0.01295-0.10233-1.69302 0.676471-1.83529-1.75584 Median 0 0 0 0 0 0-0.4 0.2-0.6-0.4 Standard Deviation (s) 0.50662 0.501611 0.512003 0.526971 0.512413 1.154595 3.550814 2.164039 3.821778 3.648954 Range 3.8 3.4 4 3.6 3.6 5.5 15.2 9.2 13.9 16.1 Minimum -1.9-1.3-1.9-1.5-1.5-3.6-10.3-3.4-11.2-11.2 Maximum 1.9 2.1 2.1 2.1 2.1 1.9 4.9 5.8 2.7 4.9 Number of Sample 142 122 164 102 224 43 43 34 34 77 2σ 1.013241 1.003222 1.024006 1.053942 1.024826 2.30919 7.101629 4.328079 7.643557 7.297908 (Unit: mm) Exclude Set-up Errors -> 2.075019 7.030411 4.205196 7.570546 7.225593

Error Distributions of Interest Points (7 Lung Pat.) Set-up Error (Positioning) is about 1 mm at 2σ. Marker Errors does not always correspond to the internal motion errors of tumors... 11 mm Max & 7 mm at 2σ for Inferior Direction. Excluding 1 patient having large errors, 6 mm Max & 3 mm at 2σ. Additional Margin (1/3 * IM) is max 3 mm.

Summary(1) 1. Commissioning (beam and clinical) was accomplished in a very short time. 2. Treatments have been safely started from March 2010. 3. Machine is operating very smoothly and we treated 92 patients last year. 4. We designed therapeutic carbon beams based on NIRS experiences of clinical trials. 5. It can be justified to use fixed ridge filter for various fractionation sizes. 6. We introduced Geant 4 Monte Carlo simulation for calculating LET distributions of fragmented particles produced in the ridge filter and water phantom.

Summary(2) 7. A new treatment planning system Xio-N has been used at Gunma University after careful commissioning of the system. 8. Motion is measured for each patient by 4DCT to determine margins. 9. From the analysis of X-ray images of patient positioning, set-up and Internal Margins (adding 1/3 of motion) are considered to be almost reasonable. 10. Further investigation is required.

Thank you for your attention 60