UltrasoundeCT fusion compared with MReCT fusion for postimplant dosimetry in permanent prostate brachytherapy

Similar documents
Defining a magnetic resonance scan sequence for permanent seed prostate brachytherapy postimplant assessment

Trina Lynd, M.S. Medical Physicist Lifefirst Imaging & Oncology Cullman, AL Tri-State Alabama, Louisiana and Mississippi Spring 2016 Meeting April

DOSIMETRIC OPTIONS AND POSSIBILITIES OF PROSTATE LDR BRACHYTHERAPY WITH PERMANENT I-125 IMPLANTS

Transperineal Interstitial Permanent Prostate Brachytherapy (TIPPB) Quality Assurance Guidelines

Measurement of craniocaudal catheter displacement between fractions in computed tomography based high dose rate brachytherapy of prostate cancer

Magnetic resonance imaging-based treatment planning for prostate brachytherapy

MRI Based treatment planning for with focus on prostate cancer. Xinglei Shen, MD Department of Radiation Oncology KUMC

A Magnetic Resonance-based Seed Localization Method for I-125 Prostate Implants

Patient Safety Focused QA. LDR Brachytherapy Vrinda Narayana

Quality Assurance of Ultrasound Imaging in Radiation Therapy. Zuofeng Li, D.Sc. Murty S. Goddu, Ph.D. Washington University St.

20 Prostate Cancer Dan Ash

TRANSRECTAL ULTRASOUND-GUIDED PROSTATE BRACHYTHERAPY

Improved prostate delineation in prostate HDR brachytherapy with TRUS-CT deformable registration technology: A pilot study with MRI validation

Real-time brachytherapy for prostate cancer implant analysis

Outline - MRI - CT - US. - Combinations of imaging modalities for treatment planning

Practical considerations in the selection of seed strength for prostate implants

Using Task Group 137 to Prescribe and Report Dose. Vrinda Narayana. Department of Radiation Oncology University of Michigan. The

Permanent Prostate Brachytherapy Post Procedure Evaluation

CLINICAL WORKSHOP IMAGE-GUIDED HDR BRACHYTHERAPY OF PROSTATE CANCER

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 6, NUMBER 2, SPRING 2005

Acknowledgements. QA Concerns in MR Brachytherapy. Learning Objectives. Traditional T&O. Traditional Summary. Dose calculation 3/7/2015

Radiation Therapy for Prostate Cancer. Resident Dept of Urology General Surgery Grand Round November 24, 2008

Dosimetric effects of prone and supine positions on post-implant assessments for prostate brachytherapy

Ritu Raj Upreti, S. Dayananda, R. L. Bhalawat*, Girish N. Bedre*, D. D. Deshpande

CyberKnife Monotherapy for Prostate Cancer

7/23/2014. SAM-HDR Brachytherapy II: Integration of Real Time Imaging. US-based prostate brachytherapy: are we there yet? No conflict of interest

The benefit of a preplanning procedure - view from oncologist. Dorota Kazberuk November, 2014 Otwock

INTRAOPERATIVE DYNAMIC DOSE OPTIMIZATION IN PERMANENT PROSTATE IMPLANTS EVA K. LEE, PH.D.,* AND MARCO ZAIDER, PH.D.

doi: /j.ijrobp CLINICAL INVESTIGATION

HDR vs. LDR Is One Better Than The Other?

Brachytherapy Planning and Quality Assurance w Classical implant systems and modern computerized dosimetry w Most common clinical applications w

Brachytherapy Planning and Quality Assurance

ADVANCED TECHNOLOGY CONSORTIUM (ATC) CREDENTIALING PROCEDURES FOR LUNG BRACHYTHERAPY IMPLANT PROTOCOLS

Interobserver variation in cervical cancer tumor delineation for image-based radiotherapy planning among and within different specialties

Image Fusion, Contouring, and Margins in SRS

MEDICAL POLICY. SUBJECT: BRACHYTHERAPY OR RADIOACTIVE SEED IMPLANTATION FOR PROSTATE CANCER POLICY NUMBER: CATEGORY: Technology Assessment

SUPERIORITY OF A REAL TIME PLANNING TECHNIQUE OVER IMAGE GUIDED RADIATION THERAPY FOR THE TREATMENT OF PRIMARY PROSTATE CANCERS

Interpreting a rising prostate-specific antigen after brachytherapy for prostate cancer

Predicting (and avoiding) Morbidity in LDR Prostate Brachytherapy

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

3D ANATOMY-BASED PLANNING OPTIMIZATION FOR HDR BRACHYTHERAPY OF CERVIX CANCER

Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

3D CONFORMATIONAL INTERSTITIAL BRACHYTHERAPY PLANNING FOR SOFT TISSUE SARCOMA

Abstract Purpose: Material and methods: Results: Conclusions: Key words: Purpose Address for correspondence:

Herlev radiation oncology team explains what MRI can bring

Stepping source prostate brachytherapy: From target definition to dose delivery Dinkla, A.M.

Recent proceedings in Brachytherapy Physics

Prostate Cancer. What is prostate cancer?

Quantitative MR Imaging Assessment of Prostate Gland Deformation before and during MR Imaging guided Brachytherapy 1

Evaluation of Normal Tissue Complication Probability and Risk of Second Primary Cancer in Prostate Radiotherapy

Advanced Technology Consortium (ATC) Credentialing Procedures for 3D Conformal Therapy Protocols 3D CRT Benchmark*

Catheter displacement prior to the delivery of high-dose-rate brachytherapy in the treatment of prostate cancer patients

Outline. Contour quality control. Dosimetric impact of contouring errors and variability in Intensity Modulated Radiation Therapy (IMRT)

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer

A PRACTICAL METHOD TO ACHIEVE PROSTATE GLAND IMMOBILIZATION AND TARGET VERIFICATION FOR DAILY TREATMENT

Corporate Medical Policy

Intensity modulated radiotherapy (IMRT) for treatment of post-operative high grade glioma in the right parietal region of brain

Friday 23 rd March The Spa Hotel, Tunbridge Wells, Kent. Abstracts. Page 1 of 9

ARTICLE. The current role of imaging for prostate brachytherapy

IGRT Solution for the Living Patient and the Dynamic Treatment Problem

Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer?

MRI to fit your planning. Philips Panorama HFO Oncology Configuration

TG-128: Quality Assurance for Prostate Brachytherapy Ultrasound

Subject: Image-Guided Radiation Therapy

Johannes C. Athanasios Dimopoulos

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

IMRT/IGRT Patient Treatment: A Community Hospital Experience. Charles M. Able, Assistant Professor

Image Registration: The Challenge for QA Centers

OPTIMIZATION OF COLLIMATOR PARAMETERS TO REDUCE RECTAL DOSE IN INTENSITY-MODULATED PROSTATE TREATMENT PLANNING

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

Index. B Biologically effective dose (BED), 158

BRACHYTHERAPY FOR PROSTATE CANCER. Dr Brandon Nguyen MBBS(Hons), FRANZCR Radiation Oncologist, The Canberra Hospital

INTRAFRACTION PROSTATE MOTION DURING IMRT FOR PROSTATE CANCER

See it! Trust it! Treat it!

How can we best use HDR brachytherapy to escalate dose in intermediate and high risk disease? Gerard Morton Associate Professor

Advances in Treatment of Cancer by Brachytherapy in Kenya, in Particular, Prostate Cancer

Content. Acknowledgments. Prostate brachy LDR Prostate brachy HDR. Use of permanent seeds and HDR in prostate: Current practice and advances

FEE RULES RADIATION ONCOLOGY FEE SCHEDULE CONTENTS

Cone-beam CT-based adaptive planning improves permanent prostate brachytherapy dosimetry: An analysis of 1266 patients

PREDICTIVE FACTORS FOR ACUTE AND LATE URINARY TOXICITY AFTER PERMANENT PROSTATE BRACHYTHERAPY: LONG-TERM OUTCOME IN 712 CONSECUTIVE PATIENTS

Subject Index. Androgen antiandrogen therapy, see Hormone ablation therapy, prostate cancer synthesis and metabolism 49

Impact of Contouring Variability on Dose- Volume Metrics used in Treatment Plan Optimization of Prostate IMRT

Introduction. The goal of TRUS QA is to ensure your system can do all of this accurately.

Prostate Cancer. What is prostate cancer?

Feasibility of 4D IMRT Delivery for Hypofractionated High Dose Partial Prostate Treatments

INFLUENCE OF CT SLICE THICKNESS ON VOLUME AND DOSE UNCERTAINTY FOR DIFFERENT ORGANS DURING TREATMENT PLANNING FOR EARLY PROSTATE CANCER

MEDICAL POLICY SUBJECT: BRACHYTHERAPY OR RADIOACTIVE SEED IMPLANTATION FOR PROSTATE CANCER

Medical Dosimetry Graduate Certificate Program IU Graduate School & The Department of Radiation Oncology IU Simon Cancer Center

Dosimetric Analysis Report

or low dose rate (LDR), brachytherapy

2015 Radiology Coding Survival Guide

Five-year outcomes after iodine-125 seed brachytherapy for low-risk prostate cancer at three cancer centres in the UK

Stability of serrated gold coil markers in prostate localization*

Basic Concepts in Image Based Brachytherapy (GEC-ESTRO Target Concept & Contouring)

MRI/TRUS data fusion for brachytherapy.

Analysis on the Reporting of Medical Events in Permanent Prostate Brachytherapy

Factory loaded, sterilized, ready to implant plaques:!

Brachytherapy. What is brachytherapy and how is it used?

M. J. Maryanski, Three Dimensional BANG Polymer Gel Dosimeters AAPM'99, CE Course

Comparison of bulk electron density and voxel-based electron density treatment planning

Transcription:

Brachytherapy 12 (2013) 38e43 UltrasoundeCT fusion compared with MReCT fusion for postimplant dosimetry in permanent prostate brachytherapy David Bowes 1, Juanita M. Crook 2, *, Cynthia Araujo 3, Deidre Batchelar 3 1 Department of Radiation Oncology, Nova Scotia Cancer Center, Halifax, Nova Scotia, Canada 2 Department of Radiation Oncology, British Columbia Cancer Agency, Center for the Southern Interior, Kelowna, BC, Canada 3 Department of Radiation Physics, British Columbia Cancer Agency, Center for the Southern Interior, Kelowna, BC, Canada ABSTRACT Keywords: PURPOSE: Postplan evaluation is essential for quality assurance in prostate brachytherapy. MRI has demonstrated greater interobserver consistency in prostate contouring compared with CT. Although a valuable tool in postimplant assessment, MRI is costly and not always available. Our purpose is to compare dosimetry obtained using fusion of postimplant CT with preimplant transrectal ultrasound (TRUS) vs. CTeMR fusion. METHODS AND MATERIALS: Twenty patients receiving permanent 125 I seed prostate brachytherapy underwent preimplant TRUS with urethrography, 1-month CT with a Foley catheter, and 1-month MRI. No patient received androgen deprivation therapy or external beam radiotherapy. The prescription dose of 125 I implant monotherapy was 144 Gy. The preimplant TRUS and postimplant CT images were fused based on urethral position, and the CTeTRUS images were subsequently fused to the MRI using a seed-to-seed match. Dosimetric parameters for the ultrasound- and MR-derived prostate were compared. RESULTS: The mean absolute difference between dosimetry from MRI or CTeTRUS fusion for D 90 was 3.2% and in V 100 was 1.2%. Only 1 patient had a difference in MR- and ultrasound-derived D 90 of more than 10% (11.4%) and only 1 had a difference in V 100 of more than 5%. CONCLUSIONS: Fusion of preimplant TRUS with 1-month postimplant CT appears to lead to acceptable agreement with MR-based dosimetric parameters in postplan evaluation. TRUS-based volumes may be a reasonable alternative to MRI in settings where MRI is not available. Ó 2013 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved. Prostate neoplasms; Interstitial brachytherapy; Dosimetry; Quality assurance; Image fusion Introduction Postimplant evaluation is essential for quality assurance in permanent seed prostate brachytherapy (BT). CT imaging alone is most commonly used in implant evaluation, although the prostate edge is difficult to define, particularly when considering the artifact produced by the implanted seeds. MRI is associated with greater interobserver consistency and accuracy in prostate delineation Received 26 December 2011; received in revised form 19 March 2012; accepted 30 March 2012. Conflict of Interest: None of the authors declares a conflict of interest concerning the material presented in this manuscript. * Corresponding author. Department of Radiation Oncology, British Columbia Cancer Agency, Center for the Southern Interior, 399 Royal Avenue, Kelowna, BC V1Y 5L3, Canada. Tel.: þ1-250-712-3979; fax: þ1-250-712-3911. E-mail address: jcrook@bccancer.bc.ca (J.M. Crook). compared with CT, which tends to overestimate the prostate volume. This has been demonstrated both in patients receiving external beam radiotherapy (1e6) and in those undergoing permanent seed BT (7e9). Even small changes in contouring can be associated with large apparent dosimetric differences (10) highlighting the need for accurate imaging in postimplant assessment. CTeMR fusion has become a valuable tool in postimplant assessment and improves accuracy of postimplant dosimetry compared with approaches that use CT imaging only (11e13). Because MRI is limited by cost and availability, exploration of other imaging modalities may be helpful. Information from the preoperative transrectal ultrasound (TRUS), such as prostate length, shape, and volume, can be incorporated into postimplant assessment and may be an improvement over the use of CT imaging alone. A recent study by Smith et al. (8) in patients undergoing TRUS, CT, and MRI 30 days after BT showed less contouring variability 1538-4721/$ - see front matter Ó 2013 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved. http://dx.doi.org/10.1016/j.brachy.2012.03.007

D. Bowes et al. / Brachytherapy 12 (2013) 38e43 39 and closer correspondence between TRUS and MRI than that between either of these modalities and CT. This suggests that TRUS may be a viable and convenient alternative to MRI in settings where MRI is not available and should improve on the accuracy of CT-based contouring. The purpose of this study is to compare dosimetry obtained using fusion of the preimplant TRUS and Day 30 postimplant CT (CTeTRUS fusion) to fusion of the Day 30 CT to MRI (CTeMR fusion). Methods and materials Twenty men undergoing permanent 125 I seed BT at the British Columbia Cancer Agency Center for the Southern Interior between January and June 2011 were included in this study. No patients received androgen deprivation therapy (ADT) or external beam radiotherapy. The prescription dose of the 125 I BT implant was 144 Gy. Loose seeds were used for all 20 patients. Patients were eligible if urethrography was performed at the time of preoperative TRUS and if catheterization was performed with CT imaging 30 days postimplant. All patients at our institution undergo TRUS planning before implantation, generating axial images every 5 mm, including one slice above and below the prostate gland. Urethrography with aerated gel is performed for planning purposes to permit limitation of the urethral dose to 125% of the prescribed dose in the preplan. CT and MRI are generally performed 30 days postimplant, using the following MR sequence: fast spin-echo T2-weighted (1.5 T), repetition time 5 4500 ms, echo time 5 90 ms, echo train length 5 10, field of view 5 20 20 cm, 3 mm slice thickness, 0 mm gap, and bandwidth 5 80 Hz/pixel. The CT and MR images are manually fused for dosimetric assessment, using the seed positions on CT and signal voids on MR as fiducial markers. Catheterization for urethral identification at the time of the Day 30 CT is performed to facilitate calculation of urethral dose. For this study, the TRUS and CT images were fused manually based on the urethral position as determined by TRUS urethrography and the position of the Foley catheter on 1- month CT. Fusion was performed by overlying the sagittal images in the plane of the urethra to superimpose the urethral curvature to bring the base and apex into alignment (Fig. 1). The prostate was contoured on the planning TRUS images before implantation. Fusion was performed by one of two radiation oncologists (JMC or DB). The prostate was then contoured on the MR images (JMC or DB), and the fused CTeTRUS images were subsequently fused to the MRI matching MR seed voids to the seeds visible on CT. Dosimetry was then calculated based on the MRI prostate contours and the TRUS prostate contours (Fig. 2). The following dosimetric parameters for the TRUS- and MR-derived prostate were collected and compared: prostate volume, V 100, D 90, V 150, and V 200. Values are reported as medians, means, interquartile ranges, and standard deviations using SPSS (SPSS Inc., Chicago, IL) software version 17.0 for statistical analysis, with the p-value of 0.05 or less being considered statistically significant. Fig. 1. Overlaying the sagittal images in the plane of the urethra superimposes the urethral curvature and brings the base and apex into alignment. Results Dosimetric parameters were calculated using the contours from the CTeTRUS fusion and from the MReCT fusion and are shown in Table 1. There were no significant differences in D 90, V 100, V 150, and V 200 ( p!0.001) when comparing dosimetric parameters obtained using MRI and CTeTRUS fusion (Table 2). Despite this, there was a small group of patients for whom agreement in the measured parameters was not as good, as shown in Table 3. Five patients had differences in MR- and ultrasound (US)-derived D 90 of between 5% and 10%, and 1 patient had a difference of 11.4%. Such differences were much less common in V 100, V 150, and V 200, with 19 of 20 patients having a difference in V 100 of less than 5%. There were no implants in this group in which the D 90 was less than 110% of the prescription dose (as determined using either MR- or TRUS-based imaging). Although 11 of 20 patients had differences in prostate volume between MR and TRUS of more than 10%, the actual magnitude of the difference was small with a mean absolute difference as calculated between MR and US of only 3.0 cc (maximum, 7.5 cc). The relation of MR and TRUS volume is shown in Fig. 3. Discussion This study suggests that fusion of CT and TRUS may be a reasonable alternative to MR-based dosimetry in patients where MRI is not available. The major advantage of this approach is that TRUS images are readily available. Incorporating preplan TRUS into postoperative evaluation does not require the use of additional resources beyond those needed for planning, and this approach does not impose any inconvenience to the patient. In our experience, CT

40 D. Bowes et al. / Brachytherapy 12 (2013) 38e43 Table 1 Median volume and dosimetric parameters as calculated using CTeTRUS fusion and CTeMRI fusion Median value (IQ range) CTeTRUS CTeMRI Volume (cc) 32.8 (25.8e42.6) 31.1 (25.8e37.6) D 90 (%) 120.0 (117.4e132.2) 122.8 (115.0e132.4) V 100 (%) 97.8 (95.4e98.9) 97.8 (94.9e98.8) V 150 (%) 71.5 (64.7e75.6) 72.6 (62.7e77.5) V 200 (%) 37.2 (28.9e41.2) 36.0 (26.6e42.4) TRUS 5 transrectal ultrasound; IQ 5 interquartile. Fig. 2. Transverse midgland images showing prostate contours from transrectal ultrasound (TRUS, blue) and MRI (red) superimposed on (a) MR and (b) CT images. Urethra is a circle on CT and triangle on TRUS. (For interpretation of the references to color in this figure legend, the reader is referred to the web version of this article.) and TRUS images can be fused in about 5 min, and the fusion could be performed by a physician, physicist, or a dosimetrist. The utility of CTeTRUS fusion in postimplant quality assurance may be affected by a number of patient-related factors. First, the presence of the TRUS probe may deform the prostate in some patients. The most commonly observed change in shape was a result of posterior pressure of the US probe to raise the prostate to Row 1 of the template grid. Pulling posteriorly on the rectal wall causes the prostate to move anteriorly on the grid, away from the rectal wall. This results in a very flat posterior aspect of the gland. Without the probe in place, the prostate reverts to a more rounded shape with the posterior aspect closer to the rectal wall (Fig. 4). The use of a large caliber or stiff catheter at the time of CT may change the urethral curvature and make fusion of CTand TRUS more difficult (Fig. 5), but this effect can be minimized by the use of the smallest possible catheter, generally a 14 French. Either situation will inherently affect the relevance of USderived contours to the unperturbed state of the prostate. The identification of either situation could be used to trigger MRI in settings where MR is available but not routinely performed. Despite these limitations, the fused TRUS contours remained very helpful, especially at the base of the prostate as illustrated in Fig. 6. Edema is another potential source of perioperative change in prostatic shape or volume. Taussky et al. (14) evaluated the time course of edema development and resolution after permanent seed BT. The median prostate volume was 5% larger 30 days after implantation than the baseline, causing a small but statistically significant effect on the prostatic D 90. Crook et al. (15) have demonstrated that a small (12%) subset of patients has a significant amount of residual prostatic edema 30 days after implantation. Although with more experience the same group found 1-month edema based on MRI to be 1%, the improvement presumably being because of more accurate needle placement and fewer needle reinsertions at the time of implant (16). The mean difference in prostate volume based on MRI vs. TRUS was 3 cc, and this may reflect persistent postimplant edema. When edema is suspected based on CT imaging, TRUS-based dosimetry may be inadequate and MRI should be arranged to optimize implant evaluation. Table 2 Mean differences in dosimetric parameters as determined with CTeTRUS fusion vs. CTeMRI fusion Mean absolute Dosimetric parameters Mean difference (% SD) difference (% SD) Volume 4.9 10.6 9.4 6.6 D 90 0.3 4.4 3.2 2.9 V 100 0.3 1.9 1.2 1.6 V 150 0.0 2.7 2.1 1.6 V 200 0.1 1.9 1.5 1.2 TRUS 5 transrectal ultrasound; SD 5 standard deviation. Negative values indicate that larger values were calculated using CTeTRUS imaging.

D. Bowes et al. / Brachytherapy 12 (2013) 38e43 41 Table 3 Number of patients (n 5 20) with differences in CTeTRUS and MR-derived dosimetric parameters greater than 5% or 10% Dosimetric parameters # With differences O5% Volume 13 11 D 90 5 1 V 100 1 0 V 150 1 0 V 200 1 0 TRUS 5 transrectal ultrasound. # With differences O10% The use of ADT is another factor that could lead to prostate volume change over time from preplanning to implant and subsequent postimplant evaluation, especially if there has been a delay from planning TRUS to implantation, or if ADT has not been administered for long enough to achieve a stable prostate volume before BT. This study did not include patients who received ADT. If an obvious difference in prostate volume is noticed at the time of implant or at the time of postimplant CT imaging, then it would be reasonable to arrange for MRI if this is not routinely done. The total volume of the implanted seeds is small (average 100 seeds per case volume per seed 5 ~0.35 cc). This would not be expected to have a major effect on dosimetry and is certainly within the range of interobserver contouring variation. Postoperative TRUS imaging could also potentially be incorporated into postimplant evaluation, although its utility is limited by the presence of the implanted seeds, which interfere with edge detection. Furthermore, this procedure may be quite uncomfortable for the patient at 1-month postimplant and as such has not been used at our center. Fig. 3. Scatter plot of prostate volume as measured on preimplant TRUS vs. 1-month MRI. TRUS 5 transrectal ultrasound. Fig. 4. Transverse midgland images showing prostate contours from transrectal ultrasound (TRUS, blue) and MRI (red). Posterior pressure on the TRUS probe has moved the prostate anteriorly and flattened the posterior edge. Although the ultrasound and MR contours are nicely superimposed laterally and anteriorly, the presence of seeds clearly seen on CT posterior to the TRUS contour is an indication that the TRUS contour is not reliable posteriorly in this instance. (a) CT image, (b) MR image, and (c) TRUS image. (For interpretation of the references to color in this figure legend, the reader is referred to the web version of this article.)

42 D. Bowes et al. / Brachytherapy 12 (2013) 38e43 Fig. 5. Example of catheter changing urethral curvature slightly. In our experience, CTeMR and CTeTRUS fusion is not time consuming and can be quickly learned by practitioners who are experienced in TRUS-based BT planning. It is worthwhile to note some limitations in this study. The contouring was performed by two observers, both experienced in MReCT fusion and MR prostate anatomy. In the community, there may be variation in contouring skills and accuracy of fusion that have not been reflected in this study. In centers choosing to incorporate preoperative TRUS imaging in postimplant evaluation, review of fusion and contouring by multiple observers should be considered. Furthermore, implant quality in this cohort was generally excellent, with no implants having a D 90 of less than 110%. There could potentially be larger differences in US- and MR-based dosimetry in less adequate implants with a higher dose gradient along the prostatic periphery. This study did not directly compare TRUS-based with CT-based dosimetry. Contouring was performed by observers experienced in MR-based contouring, and given that the knowledge of MR-based anatomy can be used to improve CT-based contouring (17, 18), we did not believe we could provide an accurate evaluation of purely CTbased dosimetry. Such a comparison can only be made using observers who do not have experience with contouring the prostate on MRI. A recent study at our institution noted disparities in dosimetric parameters when using CT imaging alone vs. CTeMR fusion (11). We feel that TRUS-based dosimetry represents a substantial improvement over dosimetry obtained using CT imaging alone. Conclusions Fusion of preoperative TRUS images with postimplant CT in this cohort has shown very good agreement with MR-derived dosimetry after permanent seed BT. Fusion of CT and TRUS may be a reasonable alternative in settings where MRI is not readily available. Fig. 6. Transverse images at the base showing prostate contours: transrectal ultrasound (TRUS, blue), MRI (red), CT (green). (a) TRUS image, (b) CT image, and (c) MR image. (For interpretation of the references to color in this figure legend, the reader is referred to the web version of this article.) References [1] Rasch C, Barillot I, Remeijer P, et al. Definition of the prostate in CT and MRI: A multi-observer study. Int J Radiat Oncol Biol Phys 1999; 43:57e66. [2] Debois M, Oyen R, Maes F, et al. The contribution of magnetic resonance imaging to the three-dimensional treatment planning of localized prostate cancer. Int J Radiat Oncol Biol Phys 1999;45:857e865.

D. Bowes et al. / Brachytherapy 12 (2013) 38e43 43 [3] Kagawa K, Lee W, Schultheiss T, et al. Initial clinical assessment of CT-MRI image fusion software in localization of the prostate for 3D conformal radiation therapy. Int J Radiat Oncol Biol Phys 1997;38: 319e325. [4] Parker C, Damyanovich A, Haycocks T, et al. Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration. Radiother Oncol 2003;66:217e224. [5] Roach M, Faillace-Akazawa P, Malfatti C, et al. Prostate volumes defined by magnetic resonance imaging and computerized tomographic scans for three-dimensional conformal radiotherapy. Int J Radiat Oncol Biol Phys 1996;35:1011e1018. [6] Milosevic M, Voruganti S, Blend R, et al. Magnetic resonance imaging (MRI) for localization of the prostatic apex: Comparison to computed tomography (CT) and urethrography. Radiother Oncol 1998;47:277e284. [7] Usmani N, Sloboda R, Kamal W, et al. Can images obtained with high field strength magnetic resonance imaging reduce contouring variability of the prostate? Int J Radiat Oncol Biol Phys 2011;80:728e734. [8] Smith W, Lewis C, Bauman G, et al. Prostate volume contouring: A 3D analysis of segmentation using 3DTRUS, CT, and MR. Int J Radiat Oncol Biol Phys 2007;67:1238e1247. [9] McLaughlin P, Narayana V, Drake D, et al. Comparison of MRI pulse sequences in defining prostate volume after permanent implantation. Int J Radiat Oncol Biol Phys 2002;54:703e711. [10] Crook J, Milosevic M, Catton P, et al. Interobserver variation in postimplant computed tomography contouring affects quality assessment of prostate brachytherapy. Brachytherapy 2002;1:66e73. [11] Petrik D, Araujo C, Halperin R, et al. Implications of CT-imaging for postplan quality assessment in prostate brachytherapy. Int J Radiat Oncol Biol Phys 2010;78(Suppl. 1):S356. [12] Katayama N, Takemoto M, Yoshio K, et al. T2*-weighted image/ T2-weighted image fusion in postimplant dosimetry of prostate brachytherapy. J Radiat Res 2011;52:680e684. [13] Tanaka O, Hayashi S, Matsuo M, et al. Comparison of MRIbased and CT/MRI fusion-based postimplant dosimetric analysis of prostate brachytherapy. Int J Radiat Oncol Biol Phys 2006; 66:597e602. [14] Taussky D, Austen L, Toi A, et al. Sequential evaluation of prostate edema after permanent seed prostate brachytherapy using CT-MRI fusion. Int J Radiat Oncol Biol Phys 2005;62:974e980. [15] Crook J, McLean M, Yeung I, et al. MRI-CT fusion to assess postbrachytherapy prostate volume and the effects of prolonged edema on dosimetry following transperineal interstitial permanent prostate brachytherapy. Brachytherapy 2004;3:55e60. [16] Crook J, Patil N, Wallace K, et al. A phase III randomized trial of the timing of meloxicam with iodine-125 prostate brachytherapy. Int J Radiat Oncol Biol Phys 2010;77:496e501. [17] McLaughlin P, Evans C, Feng M, et al. Radiographic and anatomic basis for prostate contouring errors and methods to improve prostate contouring accuracy. Int J Radiat Oncol Biol Phys 2010;76: 369e378. [18] McLaughlin P, Narayana V, Jackson T, et al. The impact of MRI training on improvement of CT based post implant dosimetry: A six physician study. Int J Radiat Oncol Biol Phys 2005;63(Suppl. 1): S327eS328.