B-Flow, Power Doppler and Color Doppler Ultrasound in the Assessment of Carotid Stenosis: Comparison with 64-MD-CT Angiography

Similar documents
MR Advance Techniques. Vascular Imaging. Class II

Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography

Imaging for Peripheral Vascular Disease

Diploma of Medical Ultrasonography (DMU) Physical Principles of Ultrasound and Instrumentation Syllabus

Utility of Variable Helical Pitch CT Scanning Technique for CT Angiography of Aortoiliac and Lower Extremity Arteries

NADINE R. BARSOUM, M.D.; LAMIAA I.A. METWALLY, M.D. and IMAN M. HAMDY IBRAHIM, M.D.

Hrushchak N.M. The Pharma Innovation Journal 2014; 3(9): 38-42

Protokollanhang zur SPACE-2-Studie Neurology Quality Standards

RAMA-EGAT Risk Score for Predicting Coronary Artery Disease Evaluated by 64- Slice CT Angiography

CT angiography techniques. Boot camp

Computed tomographic pulmonary angiography procedures: Contrast media dilution from the venous to the systemic circulation

Hitachi Aloka Medical manufactured one of the world s first diagnostic ultrasound platforms, and today this imaging modality has become the first

Essentials of Clinical MR, 2 nd edition. 99. MRA Principles and Carotid MRA

PULMONARY EMBOLISM ANGIOCT (CTA) ASSESSMENT OF VASCULAR OCCLUSION EXTENT AND LOCALIZATION OF EMBOLI 1. BACKGROUND

Lesson 07: Ultrasound Transducers. This lesson contains 73 slides plus 16 multiple-choice questions.

Pre-and Post Procedure Non-Invasive Evaluation of the Patient with Carotid Disease

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T.

Carotid Stenosis Evaluation by 64-Slice CTA: Comparison of NASCET, ECST and CC Grading Methods

8/20/18. The Doppler Effect. Objectives. What is the Doppler Effect. Doppler principles. Spectral Waveform. Image recognition. Vascular Ultrasound

Flow Quantification from 2D Phase Contrast MRI in Renal Arteries using Clustering

Cardiac CT Techniques in Neonates (and infants)

Vascular Ultrasound: Current state, current needs, future directions

Carotid Abnormalities Coils, Kinks and Tortuosity David Lorelli M.D., RVT, FACS Michigan Vascular Association Conference Saturday, October 20, 2012

Customizing Contrast Injection for Body MDCT: Algorithmic Approach

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03

Recommendations for documentation of neurosonographic examinations

GLOBAL INNOVATION BY DESIGN

Aortic Coarctation: Evaluation with Computed Tomography Angiography in Pediatric Patients

Ultrasound in Medicine

Modifi ed CT perfusion contrast injection protocols for improved CBF quantifi cation with lower temporal sampling

2004;77:800 4 MSCT OF CORONARY ARTERY BYPASS GRAFTS. Results. CABG With Adequate Diagnostic Quality

Place for Interventional Radiology in Acute Stroke

Technological advancements improve the sensitivity of CEUS diagnostics

GE Healthcare. LOGIQ E9 XDclear 2.0. Complete Ultrasound HEAD TO TOE OBESE TO THIN NEONATE TO GERIATRIC

Original Article Application of flash dual-source CT at low radiation dose and low contrast medium dose in triple-rule-out (tro) examination

Australian and New Zealand College of Veterinary Scientists. Fellowship Examination. Veterinary Radiology Paper 1

General Imaging. Imaging modalities. Incremental CT. Multislice CT Multislice CT [ MDCT ]

An Introduction to Dual Energy Computed Tomography

Features and Benefits

Making the difference with Live Image Guidance

Performance Evaluation of Ultrasound Systems: Advanced Methods and Applications

Introduction to Biomedical Imaging

Multisection CT Venography of the Dural Sinuses and Cerebral Veins by Using Matched Mask Bone Elimination

128-slice dual-source CT coronary angiography using highpitch scan protocols in 102 patients

Combined Anatomical and Functional Imaging with Revolution * CT

Making the difference with Live Image Guidance

Noncoronary Cardiac MDCT

ULTRASOUND IMAGING EE 472 F2018. Prof. Yasser Mostafa Kadah

There are many methods to quantify carotid stenosis. 1 With

Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography

Policies and Statements D16. Intracranial Cerebrovascular Ultrasound

Duplex ultrasound is first-line imaging for all

Subtraction Helical CT Angiography of Intra- and Extracranial Vessels: Technical Considerations and Preliminary Experience

Lung Perfusion Analysis New Pathways in Lung Imaging. Case Study Brochure PLA 309 Hospital

Concepts of Imaging and Knobology

Pulmonary Embolism. Thoracic radiologist Helena Lauri

Diagnosis of Middle Cerebral Artery Occlusion with Transcranial Color-Coded Real-Time Sonography

Optimising your Doppler settings for an accurate PI. Alison McGuinness Mid Yorks Hospitals

1Pulse sequences for non CE MRA

2015 ARDMS Sonography Principles & Instrumentation Job Task Analysis Summary Report

Coronary Artery Imaging. Suvipaporn Siripornpitak, MD Inter-hospital Conference : Rajavithi Hospital

Underwater Acoustic Measurements in Megahertz Frequency Range.

Computed tomography. Department of Radiology, University Medical School, Szeged

Chapter. Non-Invasive Coronary Imaging and Assessment of Left Ventricular Function using 16-slice Computed Tomography

Carotid Artery Stenosis: Optimization of CT Angiography with a Combination of Shaded Surface Display and Source Images

Ultrasound. Computed tomography. Case studies. Utility of IQon Spectral CT in. cardiac imaging

Color Doppler Imaging Evaluation of Proximal Vertebral Artery Stenosis

HRCT Versus Volume Rendering (Three Colors, Three Densities Lung Images) in Diagnosis of Small Airway Disease: A Comparative Study

Radiation Exposure in Pregnancy. John R. Mayo UNIVERSITY OF BRITISH COLUMBIA

Intuitive. Intelligent. Innovative. General Imaging

Evaluation and treatment of intracranial aneurysms using Dual Energy CT Angiography (DECTA) and rotational Digital Subtraction Angiography (DSA).

(Department of Radiology, Beylikdüzü State Hospital, İstanbul, Turkey) Corresponding Author: Dr. Mete Özdikici

Detectability of unruptured intracranial aneurysms on thinslice non-contrast-enhanced CT

A new method of sonograph lateral resolution measurement using PSF analysis of received signal

Impact of Body Mass Index and Metabolic Syndrome on the Characteristics of Coronary Plaques Using Computed Tomography Angiography

University of Groningen. Quantitative CT myocardial perfusion Pelgrim, Gert

Impact of SSF on diagnostic performance of coronary CT angiography within one heart beat in patients with high heart rate using a 256-row detector CT

Min Li 1, Bing-bing Yu 1, Jian-hua Wu 2, Lin Xu 3, Gang Sun 1 * Abstract. Introduction

The radiation dose in retrospective

Fundamental Study on the Evaluation of the Vascular Lumen after Carotid Artery Stenting Using 3D-rotational Angiography with Diluted Contrast Medium

Imaging of the Basal Cerebral Arteries and Measurement of Blood Velocity in Adults by Using Transcranial Real-Time Color Flow Doppler Sonography

GUNDERSEN/LUTHERAN ULTRASOUND DEPARTMENT POLICY AND PROCEDURE MANUAL

Vascular and Interventional Radiology Original Research

GE Healthcare. Logiq P5 Premium

GE Healthcare. LOGIQ E9 XDclear 2.0. Complete Ultrasound HEAD TO TOE OBESE TO THIN NEONATE TO GERIATRIC

InTouch Center Local Customer Teams InTouch Agreements Parts Support

Measure #195 (NQF 0507): Radiology: Stenosis Measurement in Carotid Imaging Reports National Quality Strategy Domain: Effective Clinical Care

Radiologic Importance of a High- Resistive Vertebral Artery Doppler Waveform on Carotid Duplex Ultrasonography

Angio-CT: heart and coronary arteries

CT Myocardial Perfusion: Is there Added Value to Coronary CT?

The quantitative measurement of carotid and vertebral bloodflow

Flow Measurement Techniques from Medical Modalities for Computational Fluid Dynamics. Fukasaku K, Negoro M*

Translating Protocols Across Patient Size: Babies to Bariatric

Cardiac Computed Tomography

Quality ID #195 (NQF 0507): Radiology: Stenosis Measurement in Carotid Imaging Reports National Quality Strategy Domain: Effective Clinical Care

Case 3853 Colour-coded duplex and contrast medium enhanced ultrasonography in deep venous thrombosis in emergency patients

Renal Artery Stenosis With Severe Hypertension: A Case Report

Clinical Image Gallery Next Generation Volume 1

Chapter 4. Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands. Department of Radiology,

2 Synopsis Name and Address of Company: Bracco ALTANA Pharma GmbH Max-Stromeyer-Str. 116

Transcription:

Med. J. Cairo Univ., Vol. 85, No. 2, March: 805-809, 2017 www.medicaljournalofcairouniversity.net B-Flow, Power Doppler and Color Doppler Ultrasound in the Assessment of Carotid Stenosis: Comparison with 64-MD-CT Angiography AHMED H.F. ABBASSY, M.Sc.; RASHA WESAM, M.D.; HATEM EL-AZIZY, M.D. and SAHAR M. EL-MASHED, M.D. The Department Radiology, Faculty of Medicine, Cairo University, Egypt Abstract Background: B-flow is a new digital vascular ultrasound technique. B-flow is based on a digital subtraction principle. B-Flow provides direct visualization of blood echoes, extending the wideband resolution, high frame rates and wide dynamic range of B-mode to simultaneous imaging of blood flow and tissue. Prior to surgical treatment, it is important to differentiate the degree of intra-arterial stenosis. A decision to operate in a vascular occlusion which has not been definitively diagnosed entails an unnecessary risk for the patient and is a substantial cost factor. The purpose of this study is to evaluate whether B-flow can improve the ultrasonographic diagnosis of the degree of intra-arterial carotid stenosis over Color-Coded Doppler Sonography (CCDS) and Power Doppler (PD) in comparison to Multidetector CT-angiography (MD-CTA). Patients and Methods: Vascular ultrasonography and multislice CT angiography (MD-CTA) were performed in 25 patients in Cairo University (2012-2015) between 29 and 82 years of age with suspected intra-arterial stenosis who had been referred for CT angiography. Results: Comparison between the measured grade of intraarterial carotid stenosis using different sonographic modalities with grade of stenosis measured by CTA showed there was no significant difference between B-Flow and CTA results (p=0.289); and a significant difference when CCD and PD where used (p=0.00 and 0.01 respectively). Conclusion: B-flow improves the diagnosed of intraarterial stenosis compared to other ultrasound techniques, offering a more accurate depiction of the vessel lumen. The quantification of the degree of stenosis shows a very good correlation to MD-CTA. However, CCDS remains necessary to quantify flow velocities in order to determine haemodynamic relevance. Key Words: B-Flow Ultrasound Intraarterial stenosis Multislice CT. Correspondence to: Dr. Ahmed Hazim Farid Abbassy, The Department Radiology, Faculty of Medicine, Cairo University, Egypt Introduction B-FLOW is a new digital vascular ultrasound technique. B-flow is based on a digital subtraction principle. Up to four encoded pulses are delivered along a vector in a defined time interval. The echo sequences obtained comprise an echo signal with certain intensity, the echo amplitude, for each pixel. Only the coded echoes are analyzed and thus, interference echoes are eliminated. A signal amplitude that is adequate for imaging in B scan is attained using a pulse compression technique. The echo signals of an image line are subtracted one from another so that only the amplitude signal for a reflector, like that for flowing erythrocytes, are imaged in the time interval between two pulses [1]. B-Flow provides direct visualization of blood echoes, extending the wideband resolution, high frame rates and wide dynamic range of B-mode to simultaneous imaging of blood flow and tissue. The result is exceptional spatial, temporal and contrast resolution in blood-flow and vessel-wall display, which may improve diagnostic confidence in the evaluation of complex hemodynamics, permit earlier detection of peripheral vascular disease, and potentially providing more clinical information than other imaging modalities [2]. Prior to surgical treatment, it is important to differentiate the degree of intra-arterial stenosis. A decision to operate in a vascular occlusion which has not been definitively diagnosed entails an unnecessary risk for the patient and is a substantial cost factor [3]. The purpose of this study is to evaluate whether B-flow can improve the ultrasonographic diagnosis 805

806 B-Flow, Power Doppler & Color Doppler Ultrasound of the degree of intra-arterial carotid stenosis over Color-Coded Doppler Sonography (CCDS) and Power Doppler (PD) in comparison to Multidetector CT-angiography (MD-CTA). Patients and Methods This observational, cross sectional study was conducted at the Radiology Department of Cairo University Hospitals from 2012-2015. Detailed explanation of the study was informed to the patients before their procedures. Vascular ultrasonography and multislice CT angiography (MD-CTA) were performed in 25 patients between 27 and 82 years of age with suspected intra-arterial stenosis who had been referred for CT angiography. Inclusion criteria: Any patient with stroke or syncopal attacks with suspected carotid artery stenosis. Exclusion criteria: Patient with elevated renal functions. All patients were subjected to the following: Full history: With special emphasis on history of diabetes, smoking and hypertension. Laboratory Investigations: Renal functions Preparation: Fasting for 6 hours before Multidetector CT angiography (MD-CTA) and ultrasound. A- All patients had the following done: MD-CTA: The patients were examined using a standard protocol with a 64 detector CT scanner (Toshiba Aquilion 64, Toshiba Medical Systems, Collimation and table feed were 64 X 0.6mm, rotation time 0.33s, pitch 1, slice thickness 1mm, reconstruction interval 0.5mm. Tube voltage was set to 120kV. The contrast agent was injected into a large upper limb vein as a bolus using a dual head power injector with a flow rate of 5ml/s. 120ml Omnipaque (iohexol) with an iodine concentration of 300mg/ml was applied followed by 50ml saline. The appropriate scan delay after contrast agent application was determined by semiautomatic bolus tracking. A threshold of 100HU was selected for the tracking ROI. The imaged volume included the entire arterial system to be imaged. For the detection of stenoses, thin slice maximum intensity projections with were reconstructed.. CT angiograms were analyzed according to NA- SCET criteria. The degrees of stenosis was com- puted from measurements on multiplanar reconstructions using VITAL workstation vessel probe analysis with automated vessel analysis tool. The degree of stenosis was evaluated by the minimal intrastenotic diameter in comparison to the poststenotic diameter. Vascular US: An examiner independently performed vascular ultrasound examinations of the peripheral and extracranial carotid vessels by means of CCDS, PD and B-flow with a multifrequency linear probe (3.4-10.8 MHz) and that of the abdominal vessels using a multifrequency convex probe (2-5MHz). The ultrasound device (Logiq P6, GE Medical Systems) features a high performance processor and allows the documentation of dynamic image sequences in cine mode by a digital frame buffer. This was used to perform a comparative assessment between CCDS, PD and B-flow. The flow parameters were selected according to the automatic presets on the ultrasound device. The color gain was selected just as high as it is necessary to avoid overwriting artifacts (i.e., color pixels outside the perfused lumen of the vessel). Additionally, an automatic image gain optimization could be selected. A transmitter output of 100%, an average image correlation and an average image rate were chosen for all ultrasound modalities employed. US grading of the intra-arterial stenosis was performed by comparing the residual lumen to the relative distal uninvolved artery. B- A radiologist performed a quantitative evaluation of the stenosis of MD-CTA guided by Vitrea software automated vessel analyses blinded to the results of the ultrasound preformed by a second independent radiologist. Results In all patients with intra-arterial stenosis, it was possible to appraise intra-stenotic and post-stenotic blood flow using all US modalities. Usually intra-arterial stenoses could be imaged in their diameter extents with B-flow just about as well as with MD-CTA, while the deviations were larger for CCDS and PD. The analysis of the measurements for the intrastenotic and poststenotic diameters and the measured degree of stenosis according to the NA- SCET criteria showed differences for CCDS, PD and B-flow techniques compared to MD-CTA.

Ahmed H.F. Abbassy, et al. 807 Statistical analysis: Data were statistically described in terms of mean ± standard deviation ( ±SD), median and range when appropriate. Comparison between the different modalities and the CT was done using paired t-test for paired (matched) samples. Correlation between various variables was done using Pearson moment correlation equation for linear relation in normally distributed variables and Spearman rank correlation equation for non-normal and or monotonic non-linear relation. p-values less than 0.05 was considered statistically significant. All statistical calculations were done using computer program SPSS (Statistical Package for the Social Science; SPSS Inc., Chicago, IL, USA) release 15 for Microsoft Windows (2006). % 100 90 80 Degree of stenosis 70 60 50 40 30 CT BF CCD PD 20 10 0 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 Patients Fig. (1): Graphical representationof the statistics of intra-arterial stenosis and occlusions in the study population across four modalities; CT angiography (CTA), B-Flow (BF), Color Coded Doppler (CCD) and Power Doppler (PD). (A) (B) Fig. (2): Case 1 showing left ICA stenosis of 68% (A) CTA MIP image demonstrating the stenosis of the left ICA origin (yellow arrow). (B) CTA vessel probe analysis demonstrating a minimal intrastenotic diameter of 1.2mm and a post stenotic diameter of 3.7mm corresponding to a 68% stenosis.

808 B-Flow, Power Doppler & Color Doppler Ultrasound (A) (B) (C) (D) Fig. (3): Same patient as shown in Fig. 18 (A) SD, shows a high-stenosis of the ICA with maximal systolic flow velocity of about 264cm/s. (B) PD detected a minimal intrastenotic diameter of 1.8mm, and a poststenotic diameter of 3.3mm, corresponding to a 46% stenosis (C) CCDS detected a minimal intrastenotic diameter of 1.6 mm and a poststenotic diameter of 3.2mm, indicating a diameter stenosis of 50%. (D) B-flow shows the extent and the morphology of the stenosis and detected a minimal intrastenotic diameter of 1.1 mm, and a poststenotic diameter of 3.4mm, indicating a 68% stenosis. Discussion Vascular US is commonly the initial modality used to evaluate intra-arterial stenosis because of its low cost factor and readily availability [4]. Determining the degree an of stenosis is important for planning surgery. This is why new vascular ultrasound techniques have been evaluated to establish the extent of intraarterial stenosis which can be reliably identified in comparison to MD- CTA, which is considered the standard by many authors [5]. In the current study, we chose MD-CTA as the reference method because of its high local spatial resolution. B-flow enables markedly better angle-independent flow detection on the basis of amplitude imaging that does not depend on the Doppler principle. B-flow is a new technique that extends the resolution, frame rate, and dynamic range of B- mode to simultaneously image blood flow and tissue. B-flow relies on coded excitation to boost weak signals from blood scatters and on tissue equalization to simultaneously display flowing blood and tissue without threshold decision and overlay. B-flow provided sonographic diagnosis of intrarterial stenoses with high diagnostic reliability in our study [6]. Although all ultrasound techniques reliably detected residual flow in most of the patients in the current study, compared to widely-used US techniques such as CCDS and PD, B-flow additionally makes it possible to detect the pre-stenotic, intra-stenotic and post- stenotic flow simultaneously, especially in elongated vessels. This is also facilitated by the fact that high-velocity and lowvelocity flow phenomena are registered at the same time without flow artifacts [7]. The present study used vitrea workstation automated vessel analysis for interpretation of MD- CTA findings as opposed to manual measurements of the stenosis used in Clevert et al. study. The present study s findings are in concordance with Clevert et al. in showing the B-flow mode correlates best with CTA with a coefficient a coefficient of 0.987 (with a level of significance p< 0.0001), while PD and CCDS measurements only yielded correlation coefficients of 0.797 and 0.813, respectively.

Ahmed H.F. Abbassy, et al. 809 Conclusion: B-flow improves the diagnosis of intra-arterial carotid stenosis compared to other ultrasound techniques, offering a more accurate depiction of the vessel lumen. The quantification of the degree of stenosis shows a very good correlation with MD-CTA. However, CCDS remains necessary to quantify flow velocities in order to determine haemodynamic relevance. References 1- GE Ultrasound Technology Update: B-Flow Extends Advantages of B-Mode, 2001. 2- GE Ultrasound Technology Update: Digital Encoded Ultrasound with Application to Tissue Harmonic Imaging, 2000. 3- JUNG E.M., KUBALE R., RITTER G., et al.: Diagnostics and characterization of preocclusive stenoses and occlusions of the internal carotid artery with B-flow. Eur. Radiol., 17: 439-447, 2015. 4- POLAK J.F.: Carotid ultrasound. Radiol. Clin. North Am., 39: 569-589, 2001. 5- UMEMURA A. and YAMADA K.: B-mode flow imaging of the carotid artery. Stroke, 32: 2055-2057, 2001. 6- WESKOTT H.P. and HÖPFNER M.: Blood flow imaging within small tubes: B-Flow in comparison to color, power, pulse-wave (PW) Doppler and CT: A Phantom study. Radiology, 217: 394-398, 2000. 7- CLEVERT A., JOHNSON T., JUNG E.M., et al.: Color Doppler, power Doppler and B-flow ultrasound in the assessment of ICA stenosis: Comparison with 64-MD- CT angiography. Eur. Radiol., 17: 2149 2159, 2007.