AJO DO NOT COPY. Antibiotic Cement-Coated Plates for Management of Infected Fractures. Orthopedic Technologies & Techniques

Similar documents
Perfect partner for your infection management strategy

CASE REPORT. Bone transport utilizing the PRECICE Intramedullary Nail for an infected nonunion in the distal femur

Management for Postoperative Infection of Fractures

STIMULAN POWER TO TRANSFORM OUTCOMES

CASE REPORT. Antegrade tibia lengthening with the PRECICE Limb Lengthening technology

EXPERT TIBIAL NAIL PROTECT

Power to Transform Outcomes

Stage Protocol in the Management of Infection Following Plating of the Tibia

Technical Tip for Prosthesis of Antibiotic-Loaded Acrylic Cement (PROSTALAC) Use for Infection after Shoulder Arthroplasty

STIMULAN POWER TO TRANSFORM OUTCOMES

USE OF ANTIBIOTIC CEMENT SPACERS/BEADS IN TREATMENT OF MUSCULOSKELETAL INFECTIONS AT A.I.C. KIJABE HOSPITAL

Disclosures! Infection & Nonunions. Infection workup. Skip early infection. Culture (+) fractures. Gross Infection

Tibial osteomyelitis is a challenging problem for

Case Study: David. Conditions Treated Femoral Neck Fracture with Avascular Necrosis of the Hip. Age Range During Treatment 16 Years

INFECTION AFTER FRACTURE FIXATION A N T E K A L S T A D, S T O L A V S H O S P I T A L, N O R W A Y

EVOS MINI with IM Nailing

Open Fractures of the Tibial Diaphysis

No disclosures relevant to this topic Acknowledgement: some clinical pictures were obtained from the OTA fracture lecture series and AO fracture

LCP Anterior Ankle Arthrodesis Plates. Part of the Synthes Locking Compression Plate (LCP) System.

Intramedullary fibular fixation in the operative management of fractures of the distal tibia and fibula

Reconstruction of Segmental Bone Defects Due to Chronic Osteomyelitis with Use of an External Fixator and an Intramedullary Nail Surgical Technique

StageOne. Shoulder Cement Spacer Molds. Surgical Technique

Conversion of Pantalar fusion to total ankle replacement: A case Review. Key words: Pantalar fusion, non-union and total ankle replacement

Transmetatarsal amputation in an at-risk diabetic population: a retrospective study

Antibiotic Cement-Coated Nails for the Treatment of Infected Nonunions and Segmental Bone Defects

Treatment of Infected Tibial Nonunions with Debridement, Antibiotic Beads, and the Ilizarov Method

Case Presentation: Comminuted Fractures of the Proximal Ulna 11/28/2017. Disclosures. Surgical Strategy. Implant Choice. Melvin P.

Re+Line Bunion Correction System for Correction of Hallux Abducto Valgus Deformity

CASE STUDY: PRO-DENSE Injectable Regenerative Graft Used to Backfill a Bone Cavity Following Resection of a Giant Cell Tumor

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Surgical Management of Repeated Low-Energy Periprosthetic Femur Fractures - A Case Report -

Role of Antibiotic Cement Coated Nailing in Infected Nonunion of Tibia

E ORIGINAL ARTICLE Low extra-articular (transcondylar) fractures of the distal humerus

Increased pressures at

CELLPLEX TCP SYNTHETIC CANCELLOUS BONE

Timing of Open Reduction and Internal Fixation of Ankle Fractures

CLINICAL PRESENTATION AND RADIOLOGY QUIZ QUESTION

Correction of Traumatic Ankle Valgus and Procurvatum using the Taylor Spatial Frame: A Case Report

Outcomes of Internal Fixation in a Combat Environment. Consistent with previous conflicts, the vast majority

The Orthopaedic Coding Coach 2010 Orthopaedic Coding Tips By Karen Zupko & Associates

Elbow Fractures ORIF VS Arthroplasty

34 th Annual Meeting of the European Bone and Joint Infection Society (EBJIS)

Extramedullary Tibial Preparation

Cluster - 26 ORTHOPEDICS. X Ray of Affected Limb, MIR of Shoulder

Surgical Management of Osteomyelitis & Infected Hardware. Michael L. Sganga, DPM Orthopedics New England Natick, MA

Neurologic Damage. The most common neurologic injury following intramedullary tibial nailing is injury to the peroneal nerve.

Tibial deformity correction by Ilizarov method

Foot and Ankle Systems Coding Reference Guide

Vasu Pai FRACS, MCh, MS, Nat Board Ortho Surgeon Gisborne

PediLoc Extension Osteotomy Plate (PLEO)

Inion FreedomScrew Syndesmosis Repair. Biodegradable Fixation System

Management of a large post-traumatic skin and bone defect using an Ilizarov frame

Ankle Fractures: The Bad and the Ugly

DARCO. Bow 2 Plate SURGIC AL TECHNIQUE

Is Distraction Histiogenesis a Reliable Method to Reconstruct Segmental Bone and Acquired Leg Length Discrepancy in Tibia Fractures and Non Unions?

INVISION Total Ankle Replacement System with PROPHECY Preoperative Navigation Revision of a Failed Agility Total Ankle Replacement

KASM Knee Articulating Spacer Mold. Surgical Summary

Osteosynthesis involving a joint Thomas P Rüedi

Cost and Time Considerations: Are Minifragment Plates Worth It? Disclosure. More Disclosures. Are minifragment plates worth it? it depends!

Technical Tip: A Simple Method for Proper Placement of an Intramedullary Nail Entry Point for Tibiotalocalcaneal or Tibiocalcaneal Arthrodesis

Percutaneous Antibiotic Delivery Technique (PAD-T) New Concepts in Osteomyelitis Treatment with Long-term Outcomes

Free vascularized fibular graft for tibial pseudarthrosis in neurofibromatosis

Using Animal Models to Help Solve Clinical Problems

Plate vs Nail for Distal Tibia Fxs

Distal Femur Fractures: Tips and Tricks for Plating and Nailing? Conflict of Interest 9/24/2015

.org. Tibia (Shinbone) Shaft Fractures. Anatomy. Types of Tibial Shaft Fractures

.org. Ankle Fractures (Broken Ankle) Anatomy

Tension Band Pin System

Surgical Technique. Fibula Rod System

Total Knee Original System Primary Surgical Technique

Surgical Care at the District Hospital. EMERGENCY & ESSENTIAL SURGICAL CARE

Minimally Invasive Bunion Surgery: Methods and Outcomes

Treatment of infection

The world s first bioabsorbable bone fixation device with long term drug release - CiproScrew

CURRENT TREATMENT OPTIONS

MULTIPLE APPLICATIONS OF THE MINIRAIL

Index. orthopedic.theclinics.com. Note: Page numbers of article titles are in boldface type.

The injectable, self-setting calcium phosphate bone graft substitute.

Minimally Invasive Plating of Fractures:

Dave Laverty MD Orthopedic Trauma Surgeon

Fibula Lengthening Using a Modified Ilizarov Method S. Robert Rozbruch, MD; Matthew DiPaola, BA; Arkady Blyakher,MD

Tobacco and Bone Health

EAST PRACTICE MANAGEMENT GUIDELINES WORK GROUP: UPDATE TO PRACTICE MANAGEMENT GUIDELINES FOR PROPHYLACTIC ANTIBIOTIC USE IN OPEN FRACTURES

JuggerLoc Bone-to-Bone System for Ankle Syndesmosis Fixation. Surgical Technique

ISPUB.COM. Z Ali, L Khurshid, S Vakil, A Anjum, S Dhar OBJECTIVE METHOD PATIENTS

Technique Guide. 2.7 mm/3.5 mm LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.

S. Robert Rozbruch, MD. Chief, Limb Lengthening & Complex Reconstruction Service Professor of Clinical Orthopedic Surgery

PERIPROSTHETIC FEMUR FRACTURES AFTER THA: Treatment with Revision

Technique Guide. TomoFix Osteotomy System. A comprehensive plating system for stable fixation of osteotomies around the knee.

Percutaneous Fluoroscopic Synovial Biopsy as a New Diagnostic Test for Periprosthetic Infection after Shoulder Arthroplasty: A Feasibility Study

Clinical. Solutions. Synthes Solutions. Foot and Ankle.

AOTrauma / AORecon Masters Course Periprosthetic Fractures (Course with Anatomical Specimen)

Failed Subtrochanteric Fracture How I Decide What to Do?

Research Article. Su Djie To Rante 1 *, Henry Ricardo Handoyo 2. Received: 15 August 2016 Accepted: 10 September 2016

Patient Guide. Intramedullary Skeletal Kinetic Distractor For Tibial and Femoral Lengthening

Techique. Results. Discussion. Materials & Methods. Vol. 2 - Year 1 - December 2005

Calcium Phosphate Bone Void Filler TECHNIQUE GUIDE

Low-Profile Knotless Suture and Button Fixation Device for Ankle Syndesmosis Repair: A Study of Creep

JOURNALOF ORTHOPAEDIC TRAUMA

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Transcription:

Orthopedic Technologies & Techniques ntibiotic Cement-Coated Plates for Management of Infected Fractures Janet D. Conway, MD, Lee M. Hlad, DPM, and Samantha E. ark, DPM bstract Deep infection in the presence of an implant after open reduction and internal fixation is usually treated with removal of the implant, serial débridement procedures, lavage, intravenously administered antibiotics, and occasionally, placement of antibiotic-impregnated beads. If infection occurs during the early stages of bone healing, fracture stabilization might be compromised after implant removal. Osteomyelitis, unstable owing to a bone deficit or fracture, was treated with an antibiotic cement coated (tobramycin and vancomycin) plate. The goal was successful eradication of infection with the patient remaining infection-free for 1 year. Four patients were treated with antibiotic-coated plates for osteomyelitis and all have achieved successful union, clinically free of signs of infection for more than 1 year. One patient experienced a prominent and painful plate, necessitating removal. ased on our experience, early aggressive débridement coupled with broad-spectrum antibiotic cement coated plate insertion, provides fracture stability and helps eradicate the infection with 1 surgical procedure. Technique fter removal of implants, we perform débridement of the soft tissues with a hydroscalpel (Versajet; Smith & Nephew, London, United Kingdom), mechanical débridement of bone, and curettage with high speed burr. The wound is then irrigated with pulse pressure lavage and a minimum of 3 L sterile normal saline. The extremity is re-prepped and re-draped; the entire surgical team s gowns and gloves are changed; and new instrumentation, including cautery and suction equipment, is used. The cement is prepared with tobramycin (3.6 g) and vancomycin (1 g) per 40-g bag of cement. The plate is placed in silicon tubing, and the antibiotic-prepared cement is injected into the tubing and molded until dry. Care is taken to mold the locations of the screw holes by making incisions in the tubing at the appropriate locations. Screws are placed through the screw holes to ensure locking capability, and Kirschner wires are placed through temporary fixation holes (Figure 1). Once dry, the screws and wires are removed from the plate, and the cementcoated plate is removed from the tubing. The antibiotic-coated plate is applied to the fracture or osteotomy site and is seated with screws as appropriate (Figure 2). The wound is closed primarily. Wound drains or vacuum-assisted closure devices Deep infection in the presence of an implant after open reduction and internal fixation (ORIF) is usually treated with removal of the implant, serial débridement procedures, lavage, intravenously administered antibiotics, and, in some cases, placement of antibiotic-impregnated beads. If infection occurs during the early stages of bone healing, stabilization of the fractures might be compromised after removal of the implant. lthough antibiotic-impregnated beads offer local delivery of antibiotics, they do not provide structural support of the fracture site. The beads often are difficult to remove after in-growth of granulation tissue. In areas of subcutaneous bone, an antibiotic bead pouch might be preferred to an open wound. Published research regarding the use of antibioticcoated plates during the acute or chronic stages of infection is scarce. Plates offer the versatility of fracture stabilization, and the addition of antibiotic cement to the plates might aid in eradication of infection without necessitating a second surgery for removal. The patients provided written informed consent for print and electronic publication of these case reports. Figure 1. Prepared plate waiting for cement to dry. (Reprinted with permission from the Rubin Institute for dvanced Orthopedics, Sinai Hospital of altimore). Figure 2. Plate applied to fracture site. (Reprinted with permission from the Rubin Institute for dvanced Orthopedics, Sinai uthors Disclosure Statement: Dr. Conway wishes to report that she is a paid consultant for iomet and Medtronic and received research support from Medtronic for an unrelated study. The other authors report no actual or potential conflict of interest in relation to this article. www.amjorthopedics.com February 2015 The merican Journal of Orthopedics E49

ntibiotic Cement Coated Plates for Management of Infected Fractures are not routinely used unless there is high risk for hematoma formation. The authors prefer to have high local concentrations of antibiotic in the surrounding tissues and wound. Clinical Series Case 1 31-year-old man fell from a ladder and sustained a bimalleolar ankle fracture-dislocation that was treated with ORIF. Three weeks after initial injury, the patient presented with an infected lateral wound with purulent discharge. He was taken to the operating room for initial débridement, irrigation, and fracture stabilization with an antibiotic-coated plate and tension-band wiring of the medial malleoli. He was discharged from the hospital on day 4 after admission. Cultures of the wound grew beta-hemolytic strep group G and coagulasenegative staphylococci in broth that was sensitive to oxacillin, vancomycin, and gentamycin. The patient was treated with a 6-week regimen of Unasyn (Roerig, New York, New York), developed bony union, and has been free of clinical signs of infection for 2 years (Figures 3, 4). Case 2 27-year-old male carpenter fell from a height of 12 feet and sustained a fracture of the distal radius that was treated with external fixation. The proximal pin site became clinically infected and subsequently developed osteomyelitis. The patient had a draining wound with a fracture for 2 months. He underwent débridement with partial resection of the radius and placement of an antibiotic cement coated plate and calcium phosphate bone-void filler impregnated with antibiotics. Pathology specimens were positive for osteomyelitis, and bone cultures showed methicillin-sensitive Staphylococcus aureus Figure 3. Case 1 () nteroposterior and () lateral preoperative radiographs of a 31-year-old man with a chronic lateral wound. (MSS). He received intravenously administered antibiotic DO NOT therapy for COPY (Reprinted with permission from the Rubin Institute for dvanced Orthopedics, Sinai 6 weeks after surgery. The patient has remained free of clinical signs of infection for more than 1 year and has achieved bony union (Figures 5, 5). Figure 4. Case 1 () nteroposterior and () lateral radiographs obtained 25 months postoperatively, with the patient bearing weight, show acceptable alignment with the fibular union and functional painless nonunion of the medial malleoli. (Reprinted with permission from the Rubin Institute for dvanced Orthopedics, Sinai Figure 5. Case 2 () Lateral and () anteroposterior postoperative radiographs, obtained 14 months after surgery, of a 27-yearold man who underwent resection of the radius, which had become osteomyelitic from an infected pin-tract site. The void was filled with antibiotic cement, and an antibiotic cement coated plate was applied. (Reprinted with permission from the Rubin Institute for dvanced Orthopedics, Sinai E50 The merican Journal of Orthopedics February 2015 www.amjorthopedics.com

J. D. Conway et al Case 3 44-year-old woman with insulin-dependent diabetes mellitus and venous stasis sustained a trimalleolar ankle fracture after a low-energy fall that was initially treated with ORIF. She underwent revision ORIF to treat a malunion 3 months after initial treatment. t 8 months, the patient developed a draining sinus communicating with the plate. Computed tomography revealed nonunion and indicated infection. The patient underwent resection of the osteomyelitis and repair of the fibular nonunion with an antibiotic-coated plate. Tissue cultures were positive for coagulase-negative staphylococcus, and pathology specimens were positive for osteomyelitis. She received postoperative antibiotics intravenously and 6 weeks of antibiotic therapy after discharge from the hospital. The patient has remained free of clinical signs of infection for more than 1 year and has achieved bony union (Figures 6, 7). Case 4 48-year-old man sustained an open olecranon fracture in another country. The fracture was initially treated with 1 dose of intravenously administered antibiotics and 5 days of orally administered antibiotics. The patient returned to the United States and was treated with intravenously administered antibiotics for cellulitis of the elbow for 11 days before referral to our institution, where he underwent ORIF with placement of an antibioticcoated plate and tensionband wiring. Soft-tissue and bone cultures had no growth. He received intravenously administered antibiotics for 6 weeks. t 5 months postoperatively, the Figure 7. Case 3 Radiograph plate was removed because obtained 12 months postoperatively shows osseous union of of pain. The patient has remained free of clinical signs the fibula and medial malleoli DO NOT with bony synostosis COPY of the syndesmosis. Valgus positioning year and has achieved bony of infection for more than 1 of the ankle can be seen and Figure 6. Case 3 () nteroposterior and () lateral preoperative will be addressed if it becomes union (Figures 8-8C). radiographs of a 44-year-old woman for whom the fixation device symptomatic. (Reprinted with failed. She experienced open draining sinus of the lateral ankle. permission from the Rubin Institute Discussion (Reprinted with permission from the Rubin Institute for dvanced Orthopedics, Sinai for dvanced Orthopedics, Sinai cute infections of fractures have recently been C Figure 8. Case 4 Radiographs of a 48-year-old man who had an open olecranon fracture treated conservatively in another country. () Preoperative lateral view of the elbow. () Intraoperative lateral view of the elbow shows fracture reduction. (C) Postoperative view, obtained 6 months after surgery, shows complete bony union. (Reprinted with permission from the Rubin Institute for dvanced Orthopedics, Sinai www.amjorthopedics.com February 2015 The merican Journal of Orthopedics E51

ntibiotic Cement Coated Plates for Management of Infected Fractures treated with success by erkes and colleagues, 1 who reported a 71% union rate achieved with operative débridement, antibiotic suppression, and retention of fixation until fracture union occurs. The study by erkes and colleagues 1 had a small patient population, and larger cohorts are needed to show more reliable results; however, this treatment maintains structural support for the fracture during healing but requires multiple trips to the operating room for débridements as well as the use of systemic intravenous antibiotic therapy. technique that was developed by the primary author (Janet D. Conway, MD) and has not been described in the literature allows for use of antibiotic cement coated plates to treat early postoperative infections and osteomyelitic nonunions. This approach permits fracture stabilization and local delivery of high concentrations of broad-spectrum antibiotics and can reduce the number of débridement procedures required in the operating room. We present a technique that includes the use of antibiotic cement coated plates to treat early postoperative infections associated with fractures and nonunions in order to provide eradication of infection and bony stabilization. Our approach parallels the current theory that treating infection at a site of union is preferable to treating infection at a site of nonunion. 1 Fixation devices should remain in place until osseous union is achieved. With the addition of antibiotics to the plate, removal might not be necessary unless a device is loose, nonfunctional, or, ultimately, causing pain. Other options, such as external fixation, can be burdensome to patients and can be associated with other risks. One of our 4 patients required fixation removal because of pain at the elbow; however, even noncoated olecranon plates typically are removed because of pain after fracture healing. ntibiotic cement adds bulk to the construct and can become very prominent in areas of little soft-tissue coverage (Figure 9). Studies, assessing variables that correlate with higher likelihood of failure for primary repairs, have shown that open fracture, use of an intramedullary nail, and smoking are the highest risk factors for infected nonunion. 1 4 mong our 4 patients, 3 were smokers and 1 originally had an open fracture. Smokers have been found to have a 37% higher nonunion rate and are 2 times more likely to develop wound infection and osteomyelitis. 1,5 More than 60% of the time, infections are caused by S aureus or coagulase-negative staphylococci. 1,5,6 In our study population, 3 of the 4 patients had coagulase-negative staphylococci grow in the cultures. Implants infected with S aureus or Candida require surgical removal. Those with less virulent coagulase-negative staphylococci might not necessitate removal; however, our population had had antibiotic therapy and continued draining sinus. 5 Rightmire and colleagues 7 reported that those who develop infection earlier than 16 weeks postoperatively have a 68% success rate and that smoking is a major risk factor for infection. Development of Pseudomonas in the wound has been shown to have a positive correlation with amputation. 1,2 Infection with Pseudomonas, smoking, and involvement of the femur, tibia, ankle, or foot tended to result in failure. 1,2 eing clinically free of signs of infection after 3 months offers a 50% cure rate, with 78% at 6 months and 95% after 1 year. 2 When determining an antibiotic to use with the poly- methylmethacrylate (PMM) cement, many factors must be considered, including spectrum, heat stability, and elution characteristics. 8 synergistic effect has been seen with combinations of antibiotics (eg, vancomycin and tobramycin used together). Vancomycin concentrations increased by 103% and tobramycin by 68% when used together compared with their elution rates when used alone, showing passive opportunism. 9 This will, in essence, increase concentrations of antibiotics at the site locally, which will increase the bacteriocidal potential but also create a larger antimicrobial spectrum. 9 The authors used Cobalt one Cement (iomet Orthopedics, Inc, Warsaw, Indiana) which been shown to have higher elution properties than Simplex P one Cement (Stryker, Kalamazoo, Michigan). 3,10 The majority of elution occurs in the first 3 to 5 days but can continue for weeks after implantation. We place the cement on the plate allowing for its retention, hoping to eliminate a second surgery for removal. 8 We recommend 3.6 g of tobramycin, and 1 g of vancomycin per 40-g bag of PMM. 3 This dose has been shown to be safe in respect to renal toxicity, plus the entire dose is not administered in Figure 9. n antibiotic cement coated plate at time of removal. a single setting because only a small portion of the cement is (Reprinted with permission from the Rubin Institute for dvanced Orthopedics, Sinai used when coating the plate. We close all wounds primarily, and do not regularly use drains or vacuum-assisted closures E52 The merican Journal of Orthopedics February 2015 www.amjorthopedics.com

J. D. Conway et al to help prevent a decrease in the local concentration of the antibiotics. 11 road-spectrum antibiotics are used to coat the plate in order to cover as many microbial organisms as possible without knowing the final offending organism. In our experience, this current technique provides antibiotic delivery with bony stability, therefore eliminating the need for multiple sequential surgical procedures. This difficult patient problem does not occur with enough frequency to warrant a large randomized clinical trial. However, this technique has been effective in these cases and may be useful to orthopedic surgeons in the future. Conclusion ased on our experience, early aggressive débridement, coupled with broad-spectrum antibiotic cement coated plate insertion, provides fracture stability and helps eradicate the infection with 1 surgical procedure. Dr. Conway is Head of one and Joint Infection, International Center for Limb Lengthening, Rubin Institute for dvanced Orthopedics, Sinai Hospital of altimore, altimore, Maryland. Dr. Hlad is in private practice, Grant Medical Center, Columbus, Ohio. Dr. ark is Podiatric Surgeon, vita Health System Galion Orthopedic Center, Galion, Ohio. cknowledgment: The authors thank Dori Kelly, M, for professional manuscript editing. ddress correspondence to: Janet D. Conway, MD, International Center for Limb Lengthening, Rubin Institute for dvanced Orthopedics, Sinai Hospital of altimore, 2401 West elvedere venue, altimore, MD 21215 (tel, 410-601-1726; fax, 410-601-4292; e-mail, jconway@lifebridgehealth.org). m J Orthop. 2015;44(2):E49-E53. Copyright Frontline Medical Communications Inc. 2015. ll rights reserved. References 1. erkes M, Obremskey WT, Scannell, et al. Maintenance of hardware after early postoperative infection following fracture internal fixation. J one Joint Surg m. 2010;92(4):823-828. 2. Tice D, Hoaglund P, Shoultz, D. Risk factors and treatment outcomes in osteomyelitis. J ntimicrob Chemother. 2003;51(5):1261-1268. 3. Patzakis MJ, Zalavras CG. Chronic posttraumatic osteomyelitis and infected nonunion of the tibia: current management concepts. J m cad Orthop Surg. 2005;13(6):417-427. 4. Castillo RC, osse MJ, MacKenzie EJ, Patterson M; LEP Study Group. Impact of smoking on fracture healing and risk of complications in limbthreatening open tibia fractures. J Orthop Trauma. 2005;19(3):151-157. 5. Liporace F, Yoon RS, Frank M, et al. Use of an antibiotic plate for infected periprosthetic fracture in total hip arthroplasty. J Orthop Trauma. 2012;26(3):e18-e23. 6. Darouiche RO. Treatment of infections associated with surgical implants. N Engl J Med. 2004;350(14):1422-1429. 7. Rightmire E, Zurakowski D, Vrahas M. cute infections after fracture repair: management with hardware in place. Clin Orthop. 2008;466(2):466-472. 8. dams K, Couch L, Cierny G, Calhoun J, Mader JT. In vitro and in vivo evaluation of antibiotic diffusion from antibiotic-impregnated polymethylmethacrylate beads. Clin Orthop. 1992;(278):244-252. 9. Penner MJ, Masri, Duncan CP. Elution characteristics of vancomycin and tobramycin combined in acrylic bone-cement. J rthroplasty. 1996;11(8):939-944. 10. Greene N, Holtom PD, Warren C, et al. In vitro elution of tobramycin and vancomycin polymethylmethacrylate beads and spacers from Simplex and Palacos. m J Orthop. 1998;27(3):201-205. 11. Kalil GZ, Ernst EJ, Johnson SJ, et al. Systemic exposure to aminoglycosides following knee and hip arthroplasty with aminoglycoside-loaded bone cement implants. nn Pharmacother. 2012;46(7-8):929-934. www.amjorthopedics.com February 2015 The merican Journal of Orthopedics E53