Retrospective Dosimetry Based on Long Lived Free Radicals

Similar documents
EPR Dosimetry for Triage after a Major Radiation Event

Radiation Environment and Medicine 2017 Vol.6, No Regular Article

Principles of Radiation

Contamination from Possible Solar Light Exposures in ESR Dosimetry Using Human Tooth Enamel

Improved Nuclear Device: Accessing Casualties,

THE FUNDAMENTALS OF NUCLEAR DISASTER PLANNING

Thomas S. Tenforde. President CIRMS 2006 Conference. National Institute of Standards & Technology Gaithersburg, Maryland October 23-25, 2006

NIH Public Access Author Manuscript Health Phys. Author manuscript; available in PMC 2013 September 01.

Triage, Monitoring And Dose Assessment For People Exposed To Ionising Radiation Following A Malevolent Act

Blood-Based Ultra-High-Throughput Radiation Biodosimetry

EPR Dosimetry of Whole Deciduous Tooth Using a Constant Rotation Goniometer and Background Subtraction with a Dentine Standard

Medical Countermeasures Against Radiological Terrorism! John Moulder, Ph.D.

DOWNLOAD OR READ : IONIZING RADIATION EFFECTS IN ELECTRONICS FROM MEMORIES TO IMAGERS DEVICES CIRCUITS AND SYSTEMS BOOK 50 PDF EBOOK EPUB MOBI

Application(s) of Alanine

Medical Response to Nuclear and Radiological Events

Nuclear energy, nuclear technologies, and radiological protection Vocabulary. Part 4: Dosimetry for radiation processing

Radiological Injuries

Dosimetry using Environmental and Biological Materials. Radiobiology Division, University of Utah

RERF s Views on Residual Radiation 8 December 2012 Radiation Effects Research Foundation. Introduction

Fukushima nuclear power plant and your health

BIOLOGICAL EFFECTS OF

PERSONNEL MONITORING AND DOSIMETRY POLICIES

LYMHOCYTE CHROMOSOMAL ABERRATION ASSAY IN RADIATION BIODOSIMETRY

Radiation Dosimeters for Foods. Ashish Anand Department of Biological and Agricultural Engineering Texas A&M University

Current and Planned Reports and Conferences of the National Council on Radiation Protection and Measurements

Radiologic Units: What You Need to Know

OIML R 132 RECOMMENDATION. Edition 2001 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

PHYS 383: Applications of physics in medicine (offered at the University of Waterloo from Jan 2015)

Medical Physics 4 I3 Radiation in Medicine

Advances in biological dosimetry

HEALTH PHYSICS PHYS 6700

Option D: Medicinal Chemistry

Retrospective Reconstruction of Radiation Doses of Chernobyl Liquidators by Electron Paramagnetic Resonance

Internal dosimetry in emergency situations: challenges and recent developments

nuclear science and technology

Good manufacturing practices (GMP) utilized on human blood irradiation process

High-Dose Standardization Study For γ-rays radiation processing at NIM

ACUTE RADIATION SYNDROME: Diagnosis and Treatment

Radiological Equipments for First Responders

Retrospective Reconstruction of Radiation Doses of Chernobyl Liquidators by Electron Paramagnetic Resonance

Procedure. Identify all possible radiation hazards.

RELIANT HOLDINGS LTD AND ITS AFFILIATES Safety Management System. Preparation: Safety Mgr Authority: CEO Issuing Dept: Safety Page: Page 1 of 5

Standardization of Nuclear Component Off-Carrier Processing. ASTM E61 New Orleans, LA January 27, 2015 Ryan Tracy, STERIS Isomedix Services

HSC Physics. Module 9.6. Medical Physics

ALBERTA REGULATION 182/2003 RADIATION PROTECTION REGULATION

Ionizing Radiation. Alpha Particles CHAPTER 1

WG10- Retrospective dosimetry. Progress Report

1. The Accident of Chernobyl Unit 4 of 1,000 MWe Graphite-Moderated Boiling Water Pressure Tube Reactor in 1986

Supplemental Materials

Radiation Health Effects

Dosimetry Standards and Dissemination Systems for Radiation Processing in China

J.F. Bottollier-Depois - M. Benderiter - P. Gourmelon. Contribution of IRSN in the medical management of radiological accidents

TRIAGE AND MEDICAL MANAGEMENT OF HIGH-VOLUME MASS CASULATIES AFTER A NUCLEAR DETONATION: HIROSHIMA REVISITED

Retrospective dosimetry concepts for triage / emergency situations Status and future needs

Overview of Radiation Monitoring Laboratory Capabilities in Tunisia. Azza Hammou, CNRP, Tunis RMCC-8 Meeting, Amman Jordan JUNE 2013 CONTENT

Biodosimetry: Latin American Biological Dosimetry Network (LBDNet)

Author(s) Hatano, Hiroyuki; Ganno, Shigetake;

RADIATION MONITORING EXPERIMENT USING THERMOLUMINESCENT DOSIMETER FOR THE TR 19 CYCLOTRON AREA IN NUCLEAR RESEARCH INSTITUTE

Health Physics and the Linear No-Threshold Model

An Open Letter To IAEA

Radiobiology Hall 14: Radiologic Terrorism (Completed)

Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging

QUANTIFICATION OF THE RISK-REFLECTING STOCHASTIC AND DETERMINISTIC RADIATION EFFECTS

Nuclear Plant Emergency Response. NPP Function and Malfunction: Historical Overview. Why is this training program important to you?

Dosimetry during the Chornobyl Accident

Sterilization of health care products Radiation. Part 3: Guidance on dosimetric aspects of development, validation and routine control

Process Control Methods in Radiation Technologies

American Nuclear Society Annual Meeting Chicago, June 24-28, 2012 President s Special Session

A. DeWerd. Michael Kissick. Larry. Editors. The Phantoms of Medical. and Health Physics. Devices for Research and Development.

Kazuo Sakai National Institute of Radiological Sciences Research Center for Radiation Protection

FOR CMS (MEDICARE) MEMBERS ONLY NATIONAL COVERAGE DETERMINATION (NCD) FOR MAGNETIC RESONANCE IMAGING:

Radiological Injuries

Ernest Rutherford:

Current Status of Radiological Protection in NPPs of Korea

GEX Technical Information Report

Optimization of the T2 parametric image map calculation in MRI polymer gel dosimetry

CIRMS: A Retrospective & Look Forward

Section 7 ALARA Program

Ionizing Radiation. Michael J. Vala, CHP. Bristol-Myers Squibb

Fukushima: What We All Should Know about Radiation

PAGE 1 OF 5 HEALTH, SAFETY & ENVIROMENTAL MANUAL PROCEDURE: S560 Radiation Safety REV /14/2012

Chem 481 Lecture Material 3/11/09

Dosimetric Analysis Report

INCOMING! Is your ED Ready for a Nuclear Bomb?

Aer ODE B3-20. Database System for GEX B3 Dosimetry. Aérial. Optical Dosimetry Equipment. (gamma and/or electron beam versions)

Accreditation of Dosimetry Services

Medical Use of Radioisotopes

SOLO: Radiation Risk Research in the Southern Urals

ISO INTERNATIONAL STANDARD

Neutron-Gamma Mixed field Dosimetry on a Child phantom under Therapeutic Proton Irradiation using TL Dosimeters

Public and Worker Health Impacts from the Fukushima Nuclear Plant Accident Thomas McKone, PhD & James Seward, MD, MPP

Preliminary study of MAGAT polymer gel dosimetry for boron-neutron capture therapy

SUMMARY OF PERSONAL DOSIMETRY PRACTICIES IN RCA MEMBER COUNTRIES

Effects of Radiation on Human In the Face of Fukushima Daiichi Nuclear Power Plant Accident

Final Report. The 4th IAEA-MOE Experts Meeting on Environmental Remediation. Tokyo, Date City, Minamisoma City

FOR CMS (MEDICARE) MEMBERS ONLY NATIONAL COVERAGE DETERMINATION (NCD) FOR MAGNETIC RESONANCE IMAGING:

Peak temperature ratio of TLD glow curves to investigate the spatial variation of LET in a clinical proton beam

RADIATION HAZARDS. A dabbler s perspective. Jess H. Brewer

2014 CALIBAN AND PROSPERO EXPERIMENTS FOR THE CRITICALITY ACCIDENT DOSIMETRY INTERCOMPARISON

15 December 2012 Fukushima Prefecture, Japan

Transcription:

Retrospective Dosimetry Based on Long Lived Free Radicals Harold Swartz, M.D., Ph.D. Geisel Medical School at Dartmouth

Region near Fukushima reactor site Dose distribution from fallout about May 1, 2011

Map shows the radiation dose that would be received by people in the first year following the release of radioactive material from the

Local expert advising citizens about concerns if return to homes

Problems faced by the Japanese people Effects of the earthquake Effects of the tsunami Concerns about radiation exposures Loss of confidence in the reliability of governmental authorities and maybe also other sources of authority

EPR Dosimetry Could Help! Predictions as to possible exposures if return to homes are likely to be generally accurate, but subject to local variations. The trust of the people in guidance from government is likely to be limited. Periodic direct measurements of dose for each person by EPR would be reassuring. Potential to fill in gaps in estimating total dose, e.g., during first weeks when monitoring was not fully implemented. Lower limit of detection could be increased by: Longer measurement times Obtaining background measurements from individuals who are at higher risk for exposure in the future

Electron Paramagnetic Resonance (EPR or ESR) as a Diagnostic for Large-Scale Radiation Incidents Scenario: Improvised nuclear device (10 kt) in metropolitan area Potential casualties from radiation exposure > 100,000 Designed to Meet Need for Dosimetry Diagnostics for triage Rapid classification of patients into low (< 2 Gy) and high ( 2 Gy) exposure Potential additional use: Quantitative assessment of dose across the entire plausible dose range 7

In Vivo EPR Tooth Biodosimetry Physical basis of EPR is similar to MRI (EPR uses the magnetic moment of unpaired electrons instead of magnetic nuclei; magnetic field is 100 times lower for our dosimeter) Ionizing radiation generates large numbers of unpaired electron species (carbonate anion radicals) in enamel Occurs immediately and persists in teeth for thousands of years Magnitude of the signal is proportional to the dose of radiation Independent of dose rate and type of radiation (except neutrons) Phenomenon has been recognized for decades Potential for dosimetry was first identified >40 years ago Ex vivo use of EPR dosimetry has a long history Used for dosimetry (Chernobyl and Japan) Used for archeological dating Potential for in vivo use demonstrated more than 10 years ago 8

In Vivo Dosimetry by Electron Spin Resonance Spectroscopy John M. Brady, Norman O. Aarestad and Harold M. Swartz Department of Biophysics, Division of Nuclear Medicine, Walter Reed Army Institute of Research, Walter Reed Army Medical Center, Washington, D.C. 20012 Abstract Several tissues, especially hard tissues, showed persistent electron spin resonances following in vivo or in vitro irradiations. The resonances had a linear relation to dose. Measurements in rat teeth detected responses at less than 100 rads of 60 Co irradiation. The method appears to be applicable for dosimetry of accidental irradiations, especially X- or gamma-ray exposures. DOCUMENTING LONG HISTORY OF FIELD AND OUR INVOLVEMENT Health Physics 1968. Vol. 15, pp. 43-47. 9

Clinical in vivo EPR Spectrometer Air-gap between the magnet is 50cm. Human body can be held between the magnet. The whole body measurement can be possible at the lying down position. L-band 1.2GHz EPR Spectrometer Permanent magnet :420 gauss. The loop was fixed on the human teeth. A stable free radical, PDT(Perdeuterated (15)N- Tempone ) is attached at the loop of the resonator as a reference signal.

2/21/2013 11

Calibration curve of EPR signal intensity (ex-vivo) The teeth without any irradiation have signals, background To measure the accurate dose (RIS) by this system, the level of the back ground should be estimated.

Goals for the Device to be Produced by the Contract Based on EPR dosimetry of incisor teeth in the mouth Transportable to any site and capable of operating with emergency power systems Can make the measurements at any time from immediately after the event to any time afterwards Will dependably screen for exposures of >2 Gy in 5 minutes or less will be accomplished through a SEP of 0.5 Gy Will be operable by non-expert operators Product will be ready for immediate manufacturing in sufficient quantities to meet the national needs Will have complied with all aspects of the FDA approval process 13

Feasibility of In Vivo Measurements, using Existing Deployable EPR Dosimeter In vivo measurements of upper incisor teeth Uses the current version of the instrument and established methods to measure with EPR 59 total measurements in 46 people 18 measurements in 11 TBI patients (0 Gy x 2, 1.5 Gy, 2 Gy x 12, 12 Gy x 3). Resulting in vivo calibration curve with 1.25 Gy SEP For each subject, 3-5 independent sets of data were collected, data collection for each set required 60 seconds and the results from the sets were averaged to provide a single dose estimate. Illustrates the ability to make measurements in TBI patients and the current state of the art using dosimetry based on incisors measured in vivo 14

Major Components*: 1. Magnet, 2. Microwave (cell phone frequency), 3. The Resonator that is placed on tooth *associated electronics/software not pictured 2/21/2013 15

2/21/2013 16

Current version of tooth dosimeter operated in field The operators are Ruhong Dong, M.D., D.D.S. and Ben Williams, Ph.D. (Associate director of the EPR Center) 17

Other EPR Dosimetry under development Based on same principle, using the person s tissues as the dosimeter Use of nail clippings Measurements of nails in vivo Advanced methods for measuring dose in teeth 18