Interventional Therapy for Coarctation of the Aorta

Similar documents
Coarctation of the aorta (CoA) accounts for

Dual Arterial Access for Stenting of Aortic Coarctation in Patients with Near-Total Descending Aortic Interruption

Coarctation of the Aorta

Self-Expanding Nitinol Stent Implantation for Treatment of Aortic Coarctation

IMAGES. in PAEDIATRIC CARDIOLOGY

HOW SHOULD WE FOLLOW PATIENTS AFTER AORTIC ARCH INTERVENTIONS?

Debate in Management of native COA; Balloon Versus Surgery

CP STENT. Large Diameter, Balloon Expandable Stent

Covered stents in patients with complex aortic coarctations

CoA Stenting Alexandria Experience

Transcatheter Therapy for Coarctation of the Aorta: The Results of Our Efforts

CONGENITAL HEART DEFECTS IN ADULTS

Role of Balloons and Stents in Congenital Heart Disease

PEDIATRIC AND CONGENITAL HEART DISEASE. Covered Cheatham-Platinum Stents for Serial Dilation of Severe Native Aortic Coarctation

An Adolescent Patient with Coarctation of Aorta Treated with Self-Expandable Nitinol Stent

Correspondence should be addressed to Sara Bondanza;

CAUTION: FEDERAL (USA) LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN.

Since their first use in patients with congenital heart disease

A Novel Balloon Assisted Two-Stents Telescoping Technique for Repositioning an Embolized Stent in the Pulmonary Conduit

Early and Midterm Results Following Interventional Coarctoplasty: Evaluation of Variables That Can Affect the Results

Use of covered stents and endograft as a rescue treatment in a patient with a complex form of recurrent aortic coarctation

Use of Covered Stents in the Management of Coarctation of the Aorta

Review Article Management of Aortic Coarctation in Adults: Endovascular Versus Surgical Therapy

Catheter-Based Interventions

Covered Mounted CP Stent

Percutaneous Transapical Access for Thoracic Endovascular Repair

IMAGES. in PAEDIATRIC CARDIOLOGY

Branch Pulmonary Artery Stenosis Long-term Outcomes of Endovascular Stenting

S tent implantation to treat branch pulmonary artery. The efficacy and safety of stent redilatation in congenital heart disease

S tent implantation to treat branch pulmonary artery

Nonsurgical Management of Postoperative Pulmonary Vein Stenosis

Transcatheter Pulmonary Valve Replacement Update on progress and outcomes

Percutaneous Intervention for totally Occluded Coarctation Of Aorta. John Jose, Vipin Kumar, Ommen K George Dept Of Cardiology

EVAR and TEVAR: Extending Their Use for Rupture and Traumatic Injury. Conflict of Interest. Hypotensive shock 5/5/2014. none

REBEL. Platinum Chromium Coronary Stent System. Patient Information Guide

The Petticoat Technique Managing Type B Dissection with both Early and Long Term Considerations

Citation for published version (APA): Luijendijk, P. (2014). Aortic coarctation: late complications and treatment strategies.

Aortic Coarctation Imaging and Management in Adults. Michael D. Hope, MD

Case Report International Journal of Basic and Clinical Studies (IJBCS) 2013;1(1): Elbey MA et al.

Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment

Carlos A.C. Pedra,* MD, Carlo B. Pilla, MD, Sérgio L.N. Braga, MD, César A. Esteves, MD, and Valmir F. Fontes, MD

Thoracic Endovascular Aortic Repair (TEVAR) Indications and Basic Procedure

COARCTATION REPAIR IN THE ADULT WITH COVERED STENTS

Covered CP Stent CAUTION: FEDERAL (USA) LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN.

Thoracic aortic trauma A.T.O.ABDOOL-CARRIM ACADEMIC HEAD VASCULAR SURGERY DEPARTMENT OF SURGERY UNIVERSITY OF WITWATERSRAND

Review. Percutaneous interventions of. the aorta. Future Cardiology. For reprint orders, please contact:

Endovascular Management of Thoracic Aortic Pathology Stéphan Haulon, J Sobocinski, B Maurel, T Martin-Gonzalez, R Spear, A Hertault, R Azzaoui

AORTIC DISSECTIONS Current Management. TOMAS D. MARTIN, MD, LAT Professor, TCV Surgery Director UF Health Aortic Disease Center University of Florida

Vascular V12. Covered Stent. The New Standard of Care

AORTIC COARCTATION. Synonyms: - Coarctation of the aorta

Multimodality Imaging in Aortic Diseases:

Morphological analysis of the thoracic aorta in case of TBAD without treatment.

Percutaneous reconstruction of the continuity of a functionally interrupted aortic arch using a stent

Stenting of Aortic Coarctation: Immediate and Intermediate Follow-up Results

Total Endovascular Repair Type A Dissection. Eric Herget Interventional Radiology

ROLE OF CONTRAST ENHANCED MR ANGIOGRAPHY IN AORTIC COARCTATION

NATIONAL INSTITUTE FOR CLINICAL EXCELLENCE PROGRAMME

TRANSCATHETER REPLACEMENT OF THE PULMONARY VALVE (PPVI)

Initial Experience Using the Palmaz Corinthian Stent for Right Ventricular Outflow Obstruction in Infants and Small Children

A Prospective Observational Multicenter Study of Balloon Angioplasty for the Treatment of Native and Recurrent Coarctation of the Aorta

Pediatric Cardiology. KEY WORDS: Balloon angioplasty--congenital heart disease

Jean M Panneton, MD Professor of Surgery Program Director Vascular Surgery Chief EVMS. Arch Pathology: The Endovascular Era is here

Malperfusion Syndromes Type B Aortic Dissection with Malperfusion

Coarctation of the thoracic aorta (CoA) is a relatively

Tips and Tricks to Deliver a Stengraft to the Ascending Aorta

Surgical Repair Is Safe and Effective After Unsuccessful Balloon Angioplasty of Native Coarctation of the Aorta

IMAGING the AORTA. Mirvat Alasnag FACP, FSCAI, FSCCT, FASE June 1 st, 2011

Optimal repair of acute aortic dissection

EVAR follow up: answers to uncertainties Moderators F. Moll, Y. Alimi, M. Bjorck. Inflammatory response after EVAR: causes and clinical implication

How to manage device embolization?

What Are the Current Guidelines for Treating Thoracic Aortic Disease?

Access More Patients. Customize Each Seal.

Endoanchor-assisted TEVAR

Index. cardiology.theclinics.com. Note: Page numbers of article titles are in boldface type.

Follow-up of Aortic Dissection: How, How Often, Which Consequences Euro Echo 2011

Patient Information Booklet

S tent implantation for the treatment of vessel stenosis in

Accepted Manuscript. Is A More Extensive Operation Justified for Acute Type A Dissection Repair? Dr. Leonard N. Girardi

Abdominal and thoracic aneurysm repair

NuDEL STENT DELIVERY SYSTEM COARCTATION OF THE AORTA INSTRUCTIONS FOR USE

Management of In-stent Restenosis after Lower Extremity Endovascular Procedures

For Personal Use. Copyright HMP 2013

PULMONARY ARTERY STENTING AFfER TOTAL SURGICAL CORRECTION OF RIGHT VENTRICULAR OUTFLOW TRACT OBSTRUCTIVE LESIONS

S. Bruce Greenberg, MD FNASCI and President, NASCI Professor of Radiology and Pediatrics University of Arkansas for Medical Sciences

Aortic Dissection in BAV Patients: The IRAD Experience and Beyond

Branch pulmonary artery stenosis accounts

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

Isabella Spadoni, Sandra Giusti, Pietro Bertolaccini*, Alberto Maneschi*, Giuliano Kraft, Mario Carminati

Performance of the conformable GORE TAG device in Type B aortic dissection from the GORE GREAT real world registry

Optimal Treatment of Chronic Dissection

Cardiac MRI in ACHD What We. ACHD Patients

Balloon in Balloon (BIB )

Acute dissections of the descending thoracic aorta (Debakey

Original Policy Date

How to Assess and Treat Obstructive Lesions

Ancillary Components with Z-Trak Introduction System

Adult Echocardiography Examination Content Outline

Treatment of complex thoracic cases Focus on the new Gore Active Control TAG device

Interventions in Congenital & Structural Heart Disease: Who Drives New Techniques and Devices?

Transcription:

Interventional Therapy for Coarctation of the Aorta Transcatheter treatment of native and recurrent coarctation of the aorta can be a successful procedure at acute and intermediate follow-up. BY DANIEL R. TURNER, MD, FAAP, FACC, AND THOMAS J. FORBES, MD, FACC, FSCAI A62-year-old man, with a 20-year history of treatment for essential hypertension with four antihypertensive medications, tripped while on a boat, bumped his head, and fell unconscious into the water. He was completely recovered upon his arrival to the emergency department, but due to the circumstances, a chest x- ray was obtained. Rib notching was noted, and further evaluation found severe, native coarctation of the aorta. He successfully underwent transcatheter placement of a Palmaz Genesis XD stent (Cordis Corporation, Bridgewater, NJ) to repair the coarctation, with resolution of his hypertension and discontinuation of all antihypertensive medications within 6 months of the procedure. Coarctation of the aorta occurs in 0.04% of the population and accounts for approximately 5% of all congenital heart defects. 1 A Coarctation is associated with a bicuspid aortic valve in 60% of the cases, although of more concern is that 10% have an association with a cerebral aneurysm. 2 Therefore, anyone presenting with coarctation of the Figure 1. Status after balloon dilation of a native coarctation of the aorta in a 10-year-old girl (A). Three years later, she presented with reobstruction and late aneurysm formation. A covered CP Stent (NuMed, Inc., Hopkington, NY) was successfully used to treat both the reobstruction and the aneurysm (B). B 50 ICARDIAC INTERVENTIONS TODAYINOVEMBER 2009

aorta beyond early childhood should undergo further head imaging to rule out a berry aneurysm. Although the case presented is an extremely unusual presentation for native coarctation of the aorta, it does show what progress has been made in the treatment of coarctation of the aorta during the past 20 years. In fact, in patients older than 4 years or more than 15 kg in weight, transcatheter therapy for both native and especially recurrent coarctation of the aorta has become the standard of care in the majority of institutions participating in the Congenital Cardiovascular Interventional Study Consortium (CCISC). Recent recommendations from the American Heart Association/American College of Cardiology guidelines state that the coarctation of the aorta should be repaired in patients with > 20 mm Hg peak-to-peak gradient, or in patients with < 20 mm Hg gradient with significant angiographic/imaging evidence of a narrowing (level of evidence C). Controversy continues to surround the role of transcatheter treatment of native coarctation of the aorta, with more support being present for use of balloon angioplasty in the treatment of recurrent coarctation of the aorta. 3 In this article, we discuss the present state of, and recent improvements in, transcatheter treatment of native and recurrent coarctation of the aorta in children and adults. Figure 2. Complication trend over 14 years in stenting coarctation of the aorta. BALLOON ANGIOPLASTY Balloon angioplasty was first described in 1983 by Lock et al. 4 Since then, balloon angioplasty has gained widespread acceptance for the treatment of recurrent coarctation of the aorta in all age groups. Although balloon angioplasty of native coarctation in infants is quite controversial and is regarded by most to be a palliative procedure in high-risk patients, 5 angioplasty of discrete, native coarctation in children and adults has recently shown excellent results. Walhout et al reported on 29 patients between 15 and 71 years of age with discrete, native coarctation of the aorta after successful balloon angioplasty procedures. No adverse events were encountered, with the peak systolic gradient decreasing from 52 mm Hg to 7.6 mm Hg immediately after balloon angioplasty. Intimal tears were detected in eight of 29 patients, with no evidence of acute dissection or aneurysm formation. In four of eight patients, there was resolution of the tear at 3-month angiographic followup. At a mean follow-up of 8.5 years, no dissection or late aneurysm formation was observed. One patient (3%) developed reobstruction, which required reintervention. 6 Similar results were obtained by Hassan et al in 58 patients, with a mean follow-up of 13.4 years. In this study, 7% developed aneurysm and 8% had suboptimal outcome, with a peak gradient > 20 mm Hg being observed. 7 The technique for performing balloon angioplasty for recurrent native coarctation of the aorta has evolved during the past 20 years. In infants, low-profile balloon angioplasty catheters up to 10 mm in diameter achieve sufficient atmospheres for adequate dilation of the coarctation segment. More frequently, larger-diameter, higher-profile balloon angioplasty catheters are required for adequate expansion of the narrowing. Balloon size is typically equal to or slightly larger than the diameter of the smallest segment of normal arch. Care must be taken to properly remove air from the balloon, as air emboli strokes have been reported to result after balloon rupture. Aneurysm formation at intermediate and late-term follow-up does not appear to be related to the presence of an intimal tear at the time of the initial procedure. The majority of aneurysm formation appears to be small and discrete, requiring no therapy; occasionally, however, covered stent placement or surgical intervention is required for late aneurysm formation in patients after balloon dilation of native recurrent coarctation (Figure 1A, B). 8 In summary, balloon angioplasty remains a controversial procedure in neonates and infants with native coarctation of the aorta. Satisfactory results may be achieved in older children and adults, with up to a 7% risk of aneurysms in a recent study. 7 Balloon angioplasty is the treatment of choice for recurrent coarctation of the aorta in patients of all age groups. Intermediate and late aneurysm formation has been described, and integrated aortic arch imaging should be obtained in all patients within the first 5 years from initial intervention. The results of more than 90 patients undergoing bal- NOVEMBER 2009 I CARDIAC INTERVENTIONS TODAY I 51

loon angioplasty of native and recurrent coarctation of the aorta, with follow-up imaging 1 to 3 years after initial intervention, will be reported by the CCISC later this year. STENT THERAPY FOR COARCTATION OF THE AORTA Since the 1990s, stent treatment of native or recurrent coarctation of the aorta in children older than 4 years has become the treatment of choice at many institutions. In fact, at the 36 institutions participating in the Surgical versus Stent Treatment versus Balloon Angioplasty of Native or Recurrent Coarctation of the Aorta study, in children > 15 kg, stent placement is performed more than twice as commonly than balloon angioplasty and surgical treatment combined. Stent placement for coarctation of the aorta was first performed in the early 1990s by O Laughlin et al. 9 The technique for intravascular stent treatment of coarctation of the aorta has evolved during the past 2 decades, which has led to a significant decrease in the complication rate (Figure 2). OUTCOMES Numerous studies have shown the safety and early efficacy of intravascular stent therapy, both acutely and at intermediate follow-up in the treatment of coarctation of the aorta. 10-12 In a multi-institutional retrospective study, intravascular stent placement was successful in 553 of 565 (98%) procedures. The definition of success was a systolic catheter gradient of 10 mm Hg after stent placement. The average peak systolic coarctation gradient acutely decreased from 31.6 to 2.7 mm Hg. The mean diameter of the coarctation segment increased from 7.4 to 14.3 mm. 13 Complications in this study were divided into aortic wall and technical complications. Aortic wall complications were encountered in 22 of 565 patients (4%), including intimal tear, dissection, and aortic aneurysm. Aortic rupture was seen in three patients (each younger than 22 years) and in two-thirds of patients with recurrent coarctation of the aorta. One patient underwent successful placement of a covered stent, whereas the other two patients died 1 day and 6 months, respectively, later due to severe neurologic injury associated with A B C D E Figure 3. Native coarctation in a 43-year-old woman (A). Balloon compliance testing of the coarctation segment noted it to be noncompliant. A stent was placed across the coarctation segment and dilated to an 11- X 13.1-mm diameter (B and C). A follow-up CT scan obtained the next morning noted near transection of the thoracic aorta (D). A CT scan obtained 1 month later noted resolution of the periaortic hematoma (E). 52 ICARDIAC INTERVENTIONS TODAYINOVEMBER 2009

A B C D E F Figure 4. Etiology of stent migration with subsequent placement of a Palmaz Genesis XD stent (Cordis Corporation) across the coarctation segment. Figure A notes the CP Stent placed on balloon-on-balloon (BIB) catheter across the coarctation segment. Figures B and C note proximal-to-distal inflation of the outer BIB balloon. The waveform travels superiorly toward the coarctation segment, pushing the balloon/stent inferiorly, below the coarctation segment. Figures D and E show distal expansion of the balloon catheter with the Palmaz Genesis XD stent. The balloon catheter expands superiorly to inferiorly, preventing migration of the balloon/stent catheter inferiorly. Figure F depicts the stent properly positioned across the coarctation site. the rupture. The rate of aortic wall complication remains relatively consistent before and after January 2002, remaining at 3.5% to 4% (Figure 2). Similar results have been observed in the current prospective CCISC experience. There is an increased likelihood of encountering acute aortic wall complications with (1) prestent balloon angioplasty, (2) location of the coarctation in the abdominal versus isthmus or transverse aortic arch, (3) age over 40 years, and (4) in patients inherent vessel wall abnormalities. 13-18 This is likely related to decreased aortic wall compliance and not to exceeding balloonto-coarctation ratio standards (> 3.5:1). We personally encountered a near aortic rupture in a 43-year-old woman with a balloon-to-coarctation ratio < 1.3:1. A CT scan obtained the next day noted significant aortic wall injury. Complete resolution was noted 1 month later (Figure 3A through E). Accurate assessment of aortic wall compliance is very difficult, with some interventionists advocating balloon compliance testing. A compliant balloon, which equals the smallest dimension of the transverse aortic arch or descending aorta, is inflated between 2 to 3 atm. If a > 30% waist is seen in the balloon, the aorta is considered noncompliant, and the patient is likely at higher risk for standard bare-metal stent placement. Patients believed to be at high risk include adults over the age of 22 years and those with known connective tissue disorders (eg, Turner, Marfan, and Ehlers-Danlos syndromes). Although we do not routinely perform balloon compliance testing, a similar technique is used during initial stent deployment in patients thought to be at high risk. The balloon catheter and stent are gradually inflated, distally to proximally across the coarctation segment. Low inflation pressure is used. An hour glass deformity, in which the stent is not fully expanded across the coarctation segment, is frequently seen. As long as the stent is in a stable position, aggressive dilation of the stent during initial deployment is not performed. NOVEMBER 2009 I CARDIAC INTERVENTIONS TODAY I 53

Instead, a staged approach is used, with repeat dilation at 4 to 6 months. Although a perfect angiographic outcome is not the goal, repeat dilation is only performed if the patient remains hypertensive with an upper-tolower blood pressure systolic gradient > 20 mm Hg. It is difficult to accurately report the true prevalence of aortic wall injury at intermediate and long-term follow-up because of incomplete follow-up imaging after intravascular stent treatment of recurrent or native coarctation of the aorta. Only 27% (160 of 588) procedures were followed by integrated aortic arch imaging (magnetic resonance imaging/computed tomography [CT]/cardiac catheterization) in the CCISC coarctation study. Of the 160 patients, 16 underwent planned staged repeat dilation of the coarctation stent 6 to 14 months after the initial procedure. In the 144 remaining patients, 18 (12.5%) had evidence of aortic wall injury, including 13 aortic aneurysms. Four of the 13 patients required placement of a covered stent due to the large size of the aneurysm. Aortic wall injury at intermediate follow-up was associated with a balloon-to-coarctation ratio > 3.5 and prestent balloon angioplasty at the time of the initial procedure. Development of aortic wall injuries was not related to patient age or recurrent versus native coarctation of the aorta. 19 The next most common abnormality at intermediate follow-up was in-stent restenosis secondary to neointimal proliferation within the stent (n = 16) or stent fracture (n = 6). In-stent restenosis at intermediate followup was associated with younger patient age, lower body weight, and smaller stent diameter at the initial procedure. Caution should be used when interpreting these data secondary to the small number of patients undergoing integrated aortic arch imaging at follow-up. 19 TECHNICAL COMPLICATIONS The greatest improvement in the overall complication rate for intravascular stent treatment of native or recurrent coarctation of the aorta has been in technical complications. Technical complications have decreased from > 17% before January 2002 to 5.3% after January 2002 (Figure 2). This trend continues to show gradual improvement in the current prospective CCISC study. The likelihood of encountering technical complications of any type is related to older patient age and the use of moderate sedation over general anesthesia. 13 Stent migration is the most frequently encountered technical complication, occurring in 28 of 565 (5%) of procedures reported. The most common cause of stent migration is thought to be oversizing the balloon catheter relative to the transverse aortic arch, causing the balloon/stent to migrate distal to the coarctation segment during inflation. This occurred in 14 of 28 of the stent migration procedures. The second most common cause of stent migration (nine of 28) was stent deployment using an undersized balloon. Clearly, balloon size is a critical decision, and many factors must be considered. Newer techniques have been used to decrease cardiac output to stabilize the balloon/stent during delivery. Although adenosine or esmolol have been used in this manner, 20,21 atrial or ventricular pacing offers a more reliable means to successfully decrease cardiac output. 22,23 The heart is paced at a rate at which the systolic pressure decreases by 30% to 50% from baseline. Usually, in older children and adults, this translates to a pacing rate of 160 to 185 bpm. Higher rates may be necessary for smaller children. No studies have proven that cardiac output reduction measures decrease the likelihood of stent migration. The greatest improvement in the overall complication rate for intravascular stent treatment of native or recurrent coarctation of the aorta has been in technical complications. Use of the BIB catheter plays a theoretical role in decreasing the likelihood of stent migration, although retrospective analysis has shown this not to be the case. 13 Alternate balloon inflation techniques may also be helpful. During initial inflation of the balloon, the sheath is pulled back to expose the stent but left covering the proximal shoulder of the balloon. During slow inflation, the balloon catheter fills distally to proximally, because the proximal part of the balloon cannot inflate. This allows delivery of the distal stent to the aortic wall before pulling the sheath back to deliver the more proximal stent across the coarctation segment. More accurate stent position may then be achieved. This technique and its potential advantage can be seen in a recent patient. In a 61-year-old woman, the transverse aortic arch measured 18 mm, and an 18-mm BIB balloon catheter/cp Stent (NuMed, Inc., Hopkington, NY) was advanced across the coarctation segment. The inner balloon had been previously inflated and properly positioned across the coarctation segment. Subsequent standard inflation of the outer balloon catheter noted proximal expansion of the balloon with subsequent balloon/stent migration to the midthoracic aorta (Figure 4). Subsequently, in the same patient, gradual inflation of the distal stent on a standard balloon catheter, as described previously, allowed eventual proper place- 54 ICARDIAC INTERVENTIONS TODAYINOVEMBER 2009

ment of a second stent across the coarctation. Care must be used when performing this technique using covered/premounted stents, which may be at increased risk of stent slippage off the balloon catheter. This has not been observed with bare-metal stents that have been hand-crimped onto the balloon catheter. NEW ADVANCES The use of covered stents has gained widespread acceptance in other countries but remains unapproved in the Untied States. At this time, the Coarctation Stent Trial (COAST) is underway in the United States to evaluate the use of the CP Stent for the treatment of native and recurrent coarctation of the aorta in patients weighing less than 35 kg. Atrium Medical Corporation (Hudson, NH) is launching an international trial (winter 2009) using the Advanta V12 covered stent for treatment of coarctation of the aorta in children weighing greater than 30 kg. Preliminary reports indicate that covered stents may be redilated, at least in early follow-up, to adult size. 24,25 Covered stents for treatment of balloon angioplasty aneurysms, complex coarctation of the aorta, and in patients with advanced age have been successfully used in 30 patients. No complications were encountered, with the stents remaining patent and in an excellent position on CT/magnetic resonance imaging performed 3 to 6 months later. 26 No fractures have been seen with the covered stents, which was observed in approximately 4% of the patients receiving the Palmaz Genesis XD stent at intermediate follow-up. 19 The authors believe it is of paramount importance to have a covered stent available in the catheterization lab before imparting on bare-metal stenting of native or recurrent coarctation of the aorta, especially in the high-risk patient (ie, older adults). Although dissection and subsequent aortic rupture are thankfully rare, when they do occur, the only likely successful chance at salvaging the situation is emergent placement of a covered stent. CONCLUSION Transcatheter treatment of native and recurrent coarctation of the aorta is shown to be an acutely successful procedure at acute and intermediate follow-up. Significant improvements in avoiding technical complications have been observed during the past decade. Improved follow-up, both clinically and with integrated imaging, is required before we can determine if transcatheter treatment is superior to surgery. Daniel R. Turner, MD, FAAP, FACC, is Associate Professor of Pediatrics at Wayne State University, Children s Hospital of Michigan, in Detroit. He has disclosed that he holds no financial interest in any product or manufacturer mentioned herein. Thomas J. Forbes, MD, FACC, FSCAI, is Associate Professor of Pediatrics at Wayne State University, and Director of the Cardiac Catheterization Laboratories, Children s Hospital of Michigan, in Detroit. He has disclosed that he holds no financial interest in any product or manufacturer mentioned herein. Dr. Forbes may be reached at (313) 745-5835; tforbes@dmc.org. 1. Hoffman JI, Caplan S. The incidence of congenital heart disease. J Am Coll Cardiol. 2002;39:1890-1900. 2. Connolly HM, Huston J 3rd, Brown RD Jr, et al. Intracranial aneurysms in patients with coarctation of the aorta: a prospective magnetic resonance angiographic study of 100 patients. Mayo Clin Proc. 2003;78:1491. 3. Warnes CA, Williams RG, Bashore TM, et al. ACC/AHA 2008 guidelines for the management of adults with congenital heart disease. J Am Coll Cardiol. 2008;52:143-263. 4. Lock JE, Bass JL, Amplatz K, et al. Balloon dilation angioplasty of aortic coarctations in infants and children. Circulation. 1983;68:109-116. 5. Bouzguenda L, Marini D, Ou P, et al. Percutaneous treatment of neonatal aortic coarctation presenting with severe left ventricular dysfunction as a bridge to surgery. Cardiol Young. 2009;19:244-251. 6. Walhout RJ, Suttorp MJ, Mackaij GJ, et al. Long-term outcome after balloon angioplasty of coarctation of the aorta in adolescents and adults: is aneurysm formation an issue? Catheter Cardiovasc Interv. 2009;73:549-556. 7. Hassan W, Awad M, Fawzy ME, et al. Long-term effects of balloon angioplasty on left ventricular hypertrophy in adolescent and adult patients with native coarctation of the aorta. Up to 18 years follow-up results. Catheter Cardiovasc Interv. 2007;70:881-886. 8. Forbes TJ, Matisoff D, Dysart J, et al. Treatment of coexistent coarctation and aneurysm of the aorta with covered stent in a pediatric patient. Pediatr Cardiol. 2003;24:289-291. 9. O Laughlin M, Slack MC, Grifka RG, et al. Implantation and intermediate follow-up of stents in congenital heart disease. Circulation. 1993;88:605-614. 10. Ebeid MR, Prieto LR, Latson LA. Use of balloon-expandable stents for coarctation of the aorta: initial results and intermediate-term follow-up. J Am Coll Cardiol. 1997;30:1847. 11. Hamdan MA, Maheshwari S, Fahey JT, et al. Endovascular stents for coarctation of the aorta: initial results and intermediate-term follow-up. J Am Coll Cardiol. 2001;38:1518. 12. Shah L, Hijazi ZM, Sandhu S, et al. Use of endovascular stents for the treatment of coarctation of the aorta in children and adults: immediate and midterm results. J Invas Cardiol. 2005;17:614-618. 13. Forbes TJ, Garekar S, Amin Z, et al. Procedural results and acute complications in stenting native and recurrent coarctation of the aorta in patients over 4 years of age: a multi-institutional study. Congenital Cardiovascular Interventional Study Consortium (CCISC). Catheter Cardiovasc Interv. 2007;70:276-285. 14. Varma C, Benson LN, Butany J, et al. Aortic dissection after stent dilatation for coarctation of the aorta: a case report and literature review. Catheter Cardiovasc Interv. 2003;59:528-535. 15. Tan JL, Mullen M. Emergency stent graft deployment for acute aortic rupture following primary stenting for aortic coarctation. Catheter Cardiovasc Interv. 2005;65:306-309. 16. Alcibar J, Pena N, Inguanzo R, et al. Stent-graft deployment for aortic rupture after stenting for aortic recoarctation. Texas Hear J. 2007;34:453-456. 17. Collins N, Mahadevan V, Horlick E. Aortic rupture following a covered stent for coarctation: delayed recognition. Catheter Cardiovasc Interv. 2006;68:653-655. 18. Fejzic Z, van Oort A. Fatal dissection of the descending aorta after implantation of a stent in a 19-year-old female with Turner s syndrome. Cardiol Young. 2005;15:529-531. 19. Forbes TJ, Moore P, Pedra CA, et al. Intermediate follow-up following intravascular stenting for treatment of coarctation of the aorta. Congenital Cardiovascular Interventional Study Consortium (CCISC). Catheter Cardiovasc Interv 2007;70:569-577. 20. Sivaprakasam MC, Veldtman GR, Salmon AP, et al. Esmolol-assisted balloon and stent angioplasty for aortic coarctation. Pediatr Cardiol. 2006;27:460-464. 21. Fang TD, Lippmann M, Kakazu C, et al. High-dose adenosine-induced asystole assisting accurate deployment of thoracic stent grafts in conscious patients. Ann Vasc Surg. 2008;22:602-607. 22. Moon MC, Dowdall JF, Roselli EE. The use of right ventricular pacing to facilitate stent graft deployment in the distal aortic arch: a case report. J Vasc Surg. 2008;47:629-631. 23. Nienaber CA, Kische S, Rehders TC, et al. Rapid pacing for better placing: comparison of techniques for precise deployment of endografts in the thoracic aorta. J Endovasc Ther. 2007;14:506-512. 24. Bruckheimer E, Dagan T, Amir G, et al. Covered Cheatham-platinum stents for serial dilation of severe native aortic coarctation. Catheter Cardiovasc Interv. 2009;74:117-123. 25. Butera G, Gaio G, Carminati M. Redilation of e-ptfe covered CP stents. Catheter Cardiovasc Interv. 2008;72:273-277. 26. Tzifa A, Ewert P, Brzezinska-Rajszys G, et al. Covered Cheatham-platinum stents for aortic coarctation: early and intermediate-term results. J Am Coll Cardiol. 2006;47:1457-1463. NOVEMBER 2009 I CARDIAC INTERVENTIONS TODAY I 55