Optimize your hemodialysis procedural bundle.

Similar documents
Satisfy central line placement guidelines with two convenient bedside trays.

Make the right vascular access choice, with Cook s comprehensive line of PICCs.

Thora-Para catheter drainage systems

A CATHETER FAMILY FOR ALL YOUR PATIENT NEEDS

SAFETY-DELUXE DIAGNOSTIC AND PROCEDURAL TRAYS

DISCOVER NEW HORIZONS IN FLUID DRAINAGE. Bringing Safety and Convenience to Fluid Drainage Management

Spectrum In-Service Guide. In-Service Guide

Sterile Technique & IJ/Femoral Return Demonstration

Make the right vascular access choice, with Cook s comprehensive line of PICCs.

Safe-T-Centesis catheter drainage system. Innovations in patient safety, clinician safety and procedural efficacy.

ACCEL VALVED SAFETY CENTESIS CATHETER WITH INTROCAN SAFETY TECHNOLOGY

Advance to the next generation of percutaneous tracheostomy introducers.

Lifecath Twin & Dualyse/Trilyse Permanent and Temporary Renal Catheters

E S C C R I A L T E A R. One great catheter + maximum barrier insertion. c k. p a. h e. a t. a l. r i t e. A r

DIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS

Arrow Right Heart Catheters and Vascular Access Sheaths Diagnostic Monitoring and Therapeutic Catheter Solutions

Document No. BMB/IFU/40 Rev No. & Date 00 & 15/11/2017 Issue No & Date 01 & 15/11/2017

Transjugular liver access and biopsy

Make the right vascular access choice, with Cook s comprehensive line of PICCs.

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE REF LOT STERILE EO. Manufactured for: 824 Twelfth Avenue Bethlehem, PA

PRODUCTS FOR EMERGENCY MEDICINE AND TRAUMA MEDICAL

Better Post-Op Pain Control Starts Here

Port Design. Page 1. Port Placement, Removal, and Management. Selecting a Vascular Access Device. Thomas M. Vesely, MD

Initial placement 24FR Pull PEG kit REORDER NO:

The University of Toledo Medical Center and its Medical Staff

The next step in dialysis catheter technology

Initial placement 20FR Guidewire PEG kit REORDER NO:

INNOVATIVE PRODUCTS G, J AND GJ-TUBES WITH ENFit TM CONNECTION

Central Line Care and Management

2. Need for serial arterial blood gas determinations. 2. Anticipation of the initiation of thrombolytic therapy

The High-Flow Port Designed & Indicated for Apheresis

Product Catalog 2016 EMEA

Home Health Foundation, Inc. To create more permanent IV access for patients undergoing long term IV therapy.

Peel-Apart Percutaneous Introducer Kits for

CATHETER ACCESS KIT. For use with Prometra Programmable Infusion Systems

Vascu-PICC WITH CUFF PERIPHERALLY INSERTED CENTRAL VEIN ACCESS CATHETER INSTRUCTIONS FOR USE

Petite Wound Drainage System. 13mm CWV Drainage System. CWSump. CWV with Trocar

Imbibe Bone marrow aspiration needle. Operative technique

ATI Skills Modules Checklist for Central Venous Access Devices

PRODUCTS FOR THE DIFFICULT AIRWAY. Courtesy of Cook Critical Care

AMSure UROLOGICAL CARE

Soft tissue biopsy needles

Central Venous Catheter Insertion: Assisting

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE. Rx only REF LOT. STERILE EO Sterilized using ethylene oxide

ASEPT Pleural Drainage System

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

arrow Diagnostic and drainage products More options for easier, less traumatic procedures

Vascular access in practice: best practice update

DRAINAGE. Merit.com. Corporate Headquarters, South Jordan, Utah USA. Austria Norway

A FEW WORDS ABOUT US

Soft tissue biopsy needles

THE BUSSE PAIN MANAGEMENT TRAY PROGRAM. To Building The Exact Tray For

BD PosiFlush Pre-Filled Syringes * Average reflux as measured in 4Fr PICC; data on file at BD.

ER REBOA Catheter. Instructions for Use

Radux StandTall Instructions for Use Sheath Extender and Securement Clasp

EL DORADO COUNTY EMS AGENCY FIELD PROCEDURES

LINEAR 7.5Fr. IAB Catheter

LINEAR. 7.5Fr. IAB Catheter. This document is intended to provide information to an international audience outside of the US.

Sharps Safety. Product Catalog. Needle-Pro EDGE Safety Needles and Syringe Combinations. Arterial Blood Sampling Kits

MANAGEMENT OF INTRAVASCULAR (IV) LINES AND THERAPY. All GCC Countries

Per-Q-Cath* PICC Catheters with Excalibur Introducer* System

Arrow-Clark VectorFlow Hemodialysis Catheter Because in Chronic Hemodialysis Catheters, the Tip Matters

Anaesthetic Procedure Packs Ensuring maximum barrier precautions

Peripherally Inserted Central Catheter & Midline Placement with ECG Confirmation of Tip Placement

Pneumothorax Sets Wayne Pneumothorax Sets Peters Pneumothorax Set Landers Pneumothorax Set... 7

Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family

Children s Acute Transport Service

Vasofix Safety. 1 billion times protection. Vascular Access

Successful IV Starts Revised February 2014

Veterinary Products Catalog. I.V. Catheters Needles Syringes Winged Infusion Sets

i INTERACTIVE CATALOG FIND YOUR IDEAL CANNULAE

NEEDLES & SYRINGES Retractable Needle Technology

Aspira* Peritoneal Drainage Catheter

NexSite HD, Hemodialysis Symmetric Tip Catheter for long term use. Directions for Use. Contents

Kristin Wise, MD, FHM Division of General Internal Medicine and Geriatrics Hospital Medicine 2013

drainage prepare access drain secure contain integrate

MICAFUNGIN MIXING

Fundamentals of Flushing and Locking

P: (888) F: (888)

Ponsky * PEG Safety System - "Pull" Bard * PEG Safety System - "Guidewire" Information for Use

Safe, simple and reliable closed blood sampling for effective patient blood management.9,14

Home Total Parenteral Nutrition

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

HLS Cannulae Solutions from tip to tip.

HLS Cannulae Solutions from tip to tip.

01/2006, Vidacare Corporation, all rights reserved. Vidacare, EZ-IO Product System and EZ-Connect are trademarks of the Vidacare Corporation.

Advancing Lives and the Delivery of Health Care. The High-Flow Port Designed for Apheresis

MAKE THE CLEAR CHOICE. IV Products and Accessories Designed to Help Maximize Clinical Performance While Optimizing Savings

Ultrasound Guided Vascular Access. 7/25/2016

ARROW ENDURANCE. Extended Dwell Peripheral Catheter System. Rx only.

Because your patients trust you to be your best

Emergency clamp should always be readily available in case of accidental catheter fracture

Department Policy. Code: D:PC Entity: Fairview Pharmacy Services. Department: Fairview Home Infusion. Manual: Policy and Procedure Manual

CLARIVEIN INFUSION CATHETER

interventional cardiology

Protecting Patients. Preserving Access.

Appendix E: Overview of Vascular

Percutaneous Sheath Introducer Product with Arrow Raulerson Syringe

If viewing a printed copy of this policy, please note it could be expired. Got to to view current policies.

Transcription:

Optimize your hemodialysis procedural bundle. Cook Turbo-Flo HD ACUTE HEMODIALYSIS CATHETER SETS AND TRAYS Featuring Sof-Flex catheter material for balanced performance and feel. MEDICAL

Choose from two tray solutions based on recommendations from nine organizations. The Cook Turbo-Flo HD Acute Hemodialysis Tray (standard tray) and the Cook Turbo-Flo HD Acute Hemodialysis Tray with Maximal Sterile Barriers (MSB tray) are two options designed to help meet the following agencies guidelines: Agency for Healthcare Research and Quality (AHRQ) Institute for Healthcare Improvement (IHI) Society for Healthcare Epidemiology of America (SHEA) Infectious Diseases Society of America (IDSA) Centers for Disease Control and Prevention (CDC) The Joint Commission Occupational Safety and Health Administration (OSHA) The Comprehensive Unit-Based Safety Program (CUSP) Kidney Disease Improving Global Outcomes (KDIGO) These organizations recommend maximal sterile barrier precautions and needlestick prevention to minimize injuries and reduce infections in both patients and clinicians. Organized for safety from start to finish. The standard tray provides a complete and convenient assortment of all the components you need to place an acute hemodialysis catheter at the bedside. The tray is ergonomically designed and sequentially organized to promote procedural efficiency. The MSB tray includes additional components to support your facility s ultimate goal: to reach an infection rate of zero.

Simple, tactical, and efficient for your procedure (STEP) The following components are designed to support you every step of the way: Preparation insertion checklist The maximal sterile barrier option also includes: Cap Mask with face shield Gown Full-body, tear-away fenestrated drape ChloraPrep with Hi-Lite Orange Tint Lidocaine and lidocaine label Filter straw Prefilled sodium chloride syringes Placement Cook Turbo-Flo HD Acute Hemodialysis BakSnap safety syringes EchoTip echogenic introducer needles Safe-T-J double flexible-tipped wire guide Sterile gauze pads Safety scalpel Suture with a needle driver Postprocedure Locking sharps container Needle holder cup insertion checklist (same list for preparation) Postprocedure label for the patient s chart ChloraPrep is a registered trademark of CareFusion 2200, Inc. BakSnap is a registered trademark of DuoProSS Meditech Corporation.

Simplify your procedural bundle. PREPARATION PLACEMENT POSTPROCEDURE ChloraPrep with Hi-Lite Orange Tint These one-step applicators comply with the CDC and IHI guidelines. BakSnap safety syringes The retractable and locking plunger enhances needlestick safety and reduces the risk of contamination. Using BakSnap safety syringes complies with OSHA s Needlestick Safety and Prevention Act. Disposable safety scalpel Prefilled 10 ml sodium chloride syringes Locking sharps container The sharps container reduces the risk of accidental needlesticks during disposal. Using the sharps container complies with OSHA s Needlestick Safety and Prevention Act. Lidocaine with an adhesive syringe label The label complies with The Joint Commission s guidelines. EchoTip echogenic introducer needles Extensive dimpling on the EchoTip needle s distal tip dramatically enhances visibility and maximizes the benefits of ultrasound.

insertion checklist The checklist helps you comply with CDC and IHI guidelines. Optional MSB preparation bundle The following optional components are included in the MSB trays and comply with CDC, IHI, SHEA, and IDSA guidelines: Sterile gown Mask with face shield Cap Full-body, tear-away fenestrated drape Safe-T-J double flexible-tipped wire guide Cook Turbo-Flo HD Acute Hemodialysis Suture with a needle driver Filter straw The filter straw reduces the risk that particulates will enter the syringe. The following components are also included: 22 gage needle 25 gage needle 12 ml disposable syringe CSR wrap Dilators Needle holder cup Sterile gauze pads Transducer tubing

Explore the benefits of Cook Turbo-Flo HD. The extension tubing clamps are designed for both ease of use and ease of access. The two D-shaped lumens are designed to optimize flow rates. The short extension tubing helps minimize tangling. The rotating suture hub provides securement and flexibility after catheter placement. The catheter tubing and marked hubs clearly differentiate the proximal lumen (red) from the distal lumen (blue). Cook s pliant Sof-Flex material balances performance and feel. The centimeter depth markings enhance visualization and placement accuracy. The large sideports help enhance flow.

Cook Turbo-Flo HD Acute Hemodialysis Recommended lumen volumes Fr Configuration Hub Color Lumen Length Proximal Lumen Volume ml Distal 12 Distal Proximal 15 1.3 1.4 20 1.4 1.6 25 1.6 1.7 Flow rate versus pressure* Fr Length 12 25 Hub Color Lumen Distal Proximal Approximate Flow Rate ml/min Average Maximum Pressure mm Hg Forward Flow Average Maximum Pressure mm Hg Reverse Flow 100 41.2-49.05 200 87.3-103.23 300 141.7-171.8 400 211.1-252.5 100-43.05 35.2 200-90.8 73.6 300-151.8 121.0 400-224.1 180.1 300 Forward Flow 200 Pressure mm Hg 100 0-100 Distal, blue hub Proximal, red hub -200-300 100 200 300 400 Flow Rate ml/min *In vitro data with fluid that simulated blood viscosity. Hemodialysis flow rate testing was performed using the 12 Fr, 25 long Cook Turbo-Flo HD Acute Hemodialysis. s of a shorter length should yield a higher flow rate.

Ordering information The Cook Turbo-Flo HD Acute Hemodialyis is intended for acute hemodialysis, apheresis, and hemofiltration via percutaneous insertion into the subclavian, jugular, or femoral veins. The device is a short-term use catheter (less than 30 days). Order Number Reference Part Number Lumens Fr Length Wire Guide Diameter inch Wire Guide Length Needle Gage/Length Port Minimum Lumen Volume ml Standard sets G35082 C-HDCS-1201J 2 12 15.035 60 18/5, 18/7 Proximal 1.3 G35084 C-HDCS-1201J-RSC 2 12 20.035 60 18/5, 18/7 Proximal 1.6 G35083 C-HDCS-1201J-LSC 2 12 25.035 60 18/5, 18/7 Distal 1.6 Proximal 1.7 Standard trays G35098 C-HDCSY-1201J-CCT-A 2 12 15.035 60 18/5, 18/7 Proximal 1.3 G35100 C-HDCSY-1201J-RSC-CCT-A 2 12 20.035 60 18/5, 18/7 Proximal 1.6 G35099 C-HDCSY-1201J-LSC-CCT-A 2 12 25.035 60 18/5, 18/7 Distal 1.6 Proximal 1.7 Trays with maximal sterile barriers G35104 C-HDCSY-1201J-IHI-CCT-A 2 12 15.035 60 18/5, 18/7 Proximal 1.3 G35106 C-HDCSY-1201J-RSC-IHI-CCT-A 2 12 20.035 60 18/5, 18/7 Proximal 1.6 G35105 C-HDCSY-1201J-LSC-IHI-CCT-A 2 12 25.035 60 18/5, 18/7 Distal 1.6 Proximal 1.7 Dry trays with maximal sterile barriers G35107 G35109 G35108 C-HDCSYJ-1201J-IHI-CCT-A C-HDCSYJ-1201J-RSC-IHI-CCT-A C-HDCSYJ-1201J-LSC-IHI-CCT-A 2 12 15.035 60 18/5, 18/7 2 12 20.035 60 18/5, 18/7 2 12 25.035 60 18/5, 18/7 Proximal 1.3 Proximal 1.6 Distal 1.6 Proximal 1.7 Some products or part numbers may not be available in all markets. Contact your local Cook Medical sales representative or Customer Service for details. MEDICAL COOK 03/2019 CC-D40406-EN-F