Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing

Similar documents
Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing. D. J. McMahon cewood rev

DEFIBRILLATORS ATRIAL AND VENTRICULAR FIBRILLATION

M Series with Rectilinear Biphasic Waveform Defibrillator Option Indications for Use

DEFIBRILLATORS. Prof. Yasser Mostafa Kadah

OBJECTIVE. 1. Define defibrillation. 2. Describe Need and history of defibrillation. 3. Describe the principle and mechanism of defibrillation.

Implantable Cardioverter-Defibril. Defibrillators. Ratko Magjarević

Biphasic Clinical Summaries

Cardioversion / Defibrillation / Transcutaneous Pacer Helpful Hints [ZOLL] 2018

Early Defibrillation. Dr. M. Ravishankar

Defibrillator. BiomedGuy

The heart's "natural" pacemaker is called the sinoatrial (SA) node or sinus node.

The Automated Defibrillator: A Biomedical Engineering Success Story. Dr. James A. Smith

Pediatric pacemakers & ICDs:

1. Types of Cardiac Arrhythmia

Cardiac Electrical Therapies. By Omar AL-Rawajfah, PhD, RN

QUICK SETUP GUIDE SECULIFE DFBASE

White Paper. High performance resistors are key to meeting the demanding requirements of portable medical electronics designs. Issued in June 2014

The Facts about Biphasic Defibrillation

Presented By: Barbara Furry, RN-BC, MS, CCRN, FAHA Director The Center of Excellence in Education Director of HERO

The Nuts and Bolts of ICD Therapy

RN-BC, MS, CCRN, FAHA

EnTrust D154VRC Single Chamber ICD 35J delivered 8 seconds BOL, 11.8 seconds ERI 10.7 years**** 35cc, 68g Programmable Active Can

Cardioverting with Confidence! Class Code 142

Cardioverting with Confidence: Isn t It About Time!

Puzzling Pacemakers Cheryl Herrmann, APN, CCRN, CCNS-CSC-CMC

Flowchart for ICD patients undergoing Surgery or procedures involving diathermy/magnetic fields

MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa

Electrical Interventions

Model 5392 EPG Temporary Pacer

1-Epinephrine 2-Atropine 3-Amiodarone 4-Lidocaine 5-Magnesium

Panorama. Arrhythmia Analysis Frequently Asked Questions

Transcutaneous Pacing on Zoll Defibrillator Version 4 Related Documents SOP-Zoll defibrillator ; Phillips MRX SOP Dr Randal McRoberts

ICD: Basics, Programming and Trouble-shooting

SMART Biphasic. A Proven, Fixed, Low-Energy Defibrillation Waveform

Biomedical Instrumentation

Automated External Defibrillation Principle of Early Defibrillation States that all BLS personnel be trained, equipped and allowed to operate a if

Therapeutic/Prosthetic Devices Pacemakers & Defibrillators. Biomedical Instrumentation JHU Applied Physics Lab. Dr. Nitish V. Thakor.

Defibrillation. Learning outcomes. Introduction. Mechanism of defibrillation. Factors affecting defibrillation. success. Transthoracic impedance

INTERNAL CARDIOVERSION. Lancashire & South Cumbria Cardiac Network

Pacemaker System Malfunction Resulting from External Electrical Cardioversion: A Case Report

Power to see the big picture

HeartStart. XL+ cardiac resuscitation. Ready. to save lives. Not available for sale in the U.S.

Essentials of Pacemakers and ICD s. Rajesh Banker, MD, MPH

Pacemaker Concepts and Terminology*

Electrocardiography for Healthcare Professionals

Advanced ICD Concepts

Peri-operative management of pacemakers and implantable cardiac defibrillators

Figure 2. Normal ECG tracing. Table 1.

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART I

Testing the Accuracy of ECG Captured by Cronovo through Comparison of ECG Recording to a Standard 12-Lead ECG Recording Device

Pacing Lead Implant Testing. Document Identifier

A Study of Automated External Defibrillator with the Help of Monophasic and Biphasic Pulse

Review of Pacemakers and ICD Therapy: Overview and Patient Management

Cardiac Pacing. Learning outcomes. Introduction. The cardiac impulse - its formation and its failure CHAPTER. To understand:

Perioperative Management of Cardiac Implantable Devices

EE 4BD4 Lecture 20. Therapeutic Stimulation

Transcutaneous Pacing. Approval: Medical Director James Stubblefield, MD. Approval: EMS Director Michael Petrie

Project Title Temporary Pacemaker Training Simulator

Improving quality of resuscitation. Defibrillators TEC-5600 series

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs

MEDTRONIC CARELINK NETWORK FOR PACEMAKERS. Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring

PERIOPERATIVE MANAGEMENT: CARDIAC PACEMAKERS AND DEFIBRILLATORS

DEFIB «U S E-HEART. CardioStart MEDICAL MEDIO TECHNOLOGIES BIPHASIC DEFIBRILLATORS К-ИЕЛКГ. Wmwie

CPR Guidelines - Update

Cardiac Resuscitation. HeartStart FRx. Lead the way. to save a life Philips HeartStart FRx defibrillator with Life Guidance

VENTRICULAR DEFIBRILLATOR

MARS Ambulatory ECG Analysis The power to assess and predict

BeneHeart D3. Defibrillator/Monitor. More than a fast defibrillator

Newer pacemakers also can monitor your blood temperature, breathing, and other factors and adjust your heart rate to changes in your activity.

M3535A/M3536A Instructions for Use. HeartStart MRx

SVT Discriminators. Definition of SVT Discrimination. Identify which patient populations might benefit from these features

Defibrillators TEC-8300K series. Improving quality of resuscitation

Shock-induced termination of cardiac arrhythmias

Cardiac Implanted Electronic Devices Pacemakers, Defibrillators, Cardiac Resynchronization Devices, Loop Recorders, etc.

BEDSIDE ECG INTERPRETATION

Cardiac Rhythm Device Management. PBL STOP Your acronym for a standardized follow-up

Chain of Survival. Highlights of 2010 American Heart Guidelines CPR

About atrial fibrillation (AFib) Atrial Fibrillation (AFib) What is AFib? What s the danger? Who gets AFib?

AWAY Model # RTLAGF-900 REV

Defibrillator Monitor E-HEART. User Manual

ProSim 3 and 2. Vital Signs Simulators

Indications The AED mode is to be used only on patients in cardiopulmonary arrest.

STUDY REPORT ON THE EFFECT OF RADIO WAVES ON MEDICAL DEVICES

Diagnostic capabilities of the implantable therapeutic systems

Michigan Pediatric Cardiac Protocols. Date: November 15, 2012 Page 1 of 1 TABLE OF CONTENTS


09/05/2018. True/False: All pacemakers have defibrillation capabilities.

SARASOTA MEMORIAL HOSPITAL

Dysrhythmias Chapter

ProSim 3 and 2 Vital Signs Simulators

MODEL EPG SINGLE CHAMBER TEMPORARY EXTERNAL PACEMAKER

Rigel UNI-SiM Lite. The most cost-effective patient simulator on the market. Key Features n Compact and cost-effective

ACLS Prep. Preparation is key to a successful ACLS experience. Please complete the ACLS Pretest and Please complete this ACLS Prep.

Reviewed Date: Supersedes (Policy #/description & date): Prepared by: Jacque Callis, RN Approved by: D.R. Johnson, MD

Engineering involved in Cardiac Arrest Management Sahar Sorek

Non-Invasive Transcutaneous Pacing

Rigel UNI-SiM. The world s smallest integrated NiBP, SpO2 and patient simulator. Key Features n Compact and cost-effective

Supplemental Material

Transcription:

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing Key Points Defibrillators: - know the definition & electrical value of a joule - monophasic vs biphasic types: - differences in output - know typical voltage and current values - advantages of biphasic - AED s - how they differ from full-function defibrillators - cardioversion - what it is, what it is not, and how a defibrillator is used for it - external pacers in defibrillators: - asynchronous and synchronous D. J. McMahon 141001 cewood rev 2017-10-04 local manufacturers on parade; Museum of History & Industry (MOHAI)

joule: Unit of energy or work: 1 Newton through a distance of 1 meter or James P Joule 1 amp through 1 ohm for 1 second Mathematically, the joule can be defined both ways, but the convention is to use joules for energy, and newton-meters for torque. One joule = one watt-second = ~ 0.24 calorie = ~ 0.74 foot-pound Essential monophasic defibrillator with switch A in this position, defibrillation is happening, (not charging) Coil The Lown waveform: Monophasic, damped

Basic Lown waveform creation Specific Lown waveform creation Energy in the capacitor : U = ½ CV p 2 Biphasic defibrillation: > 1990 s improvement in defib circuitry. > Achieves defibrillation in fewer attempts, using lower energies in each attempt. > Less time delay in salvaging a cardiac crisis, and less damage to the heart. > became biphasic truncated exponential (BTE) waveform (Physio Control and Philips)

Current & Time at Various Patient Impedances Insulated Gate Bipolar Transistor (IGBT): - Combines an isolated gate FET for the input, and a bipolar power transistor as a switch, in a single device. - Has the gate-drive characteristics of a MOSFET and the high-current and low-saturation-voltage capability of a bipolar transistor. - Used in medium- to high-power applications. Test loads are 50Ω

Some manufacturers of biphasic defibs provide a maximum energy of 200 joules, while many provide a maximum of 360 joules.

Pads have replaced paddles in most applications of defibrillators. Pads assure a better contact with the patient s skin, so resistive losses are minimized. They are also safer for the user. Paddles, internal as well as external, are still used in specific clinical areas (O.R., PACU, etc.) Defib voltages are very brief, but very high and potentially lethal! paddles pads spoons for OR Correct placement of the pads or paddles is important

Internal paddles for use in open-heart surgery: 2010 AHA Guidelines for pediatric defibrillation: With a manual defibrillator use a dose of 2 J/kg for the first attempt, and 4 J/kg for subsequent attempts. Placed directly on the heart to re-start the beat. Defibrillator limits energy to them at 50 joules. ECG Input Protection from Defibrillator Pulses: NE2H lamps

Automatic External Defibrillators (AED s) > Semi-automated defibs that analyze cardiac status and deliver therapeutic shock as indicated, using a pre-set algorithm and voice commands. > Intended for non-clinical settings, for use by non-clinicians. > Typical biomed maintenance consists of a functional check and a battery check. Conductive gel left on paddles from a previous use. Typical block diagram for an AED

Defibs for Cardioversion (this is not defibrillation!) > The use of a small energy pulse from a defibrillator to convert a non-lethal arrhythmia (e.g. atrial flutter) to a normal sinus rhythm > Delivers a pulse about 30ms after the peak of the R-wave, synchronized by the defibrillator > Modern units can discriminate the R-wave from the T-wave or noise spikes Timing of cardioversion pulse Defibs as External Pacemakers Defibrillators can be used as temporary external pacemakers for patients with bradycardia or other issues. Pacing is either synchronous or asynchronous : In Synchronous pacing ( Demand mode): pacer fires only when no complex is sensed for a predetermined amount of time. Do NOT cardiovert across the T-wave! In Asynchronous pacing: pacer fires at a fixed rate at preset intervals, independent of cardiac activity. ( not synchronized means the pacemaker leads and the heart follows)

Typical external pacemakers deliver a 40-millisecond impulse for each beat. The average current necessary for external pacing is from 45-100 ma, depending on the cardiac status. In pacing, the same defibrillator electrodes are used.

Major Makers of full-function Defibrillators and AEDs: October, 2014 Test equipment: Defibrillator Analyzers BC Biomedical Fluke Biomedical http://testequipmentandtools.com/acatalog/bc_online_store_defibrillator_analyzers_5.html http://assets.fluke.com/demos/biomedical/impulse/3035532_impulse_demo.html