Noxious stimuli do not modify myogenic motor evoked potentials by electrical stimulation during anesthesia with propofol-based anesthesia

Similar documents
Materials and Methods

Decreased Amplitude and Increased Latency in OR Communication During Anterior/Posterior Spinal Fusion

Neuromuscular block with vecuronium reduces the rapidly extracted auditory evoked potentials index during steady state anesthesia

British Journal of Anaesthesia 94 (2): (2005) doi: /bja/aei003 Advance Access publication October 29, 2004

An Electrode Configuration for Recording Muscle Motor Evoked Potentials in the Upper Extremities during Intraoperative Neurophysiological Monitoring

Intraoperative spinal cord monitoring is performed

BIS Monitoring. ASSESSMENT OF DEPTH OF ANAESTHESIA. Why measure depth of anaesthesia? or how to avoid. awareness in one easy lesson

Bispectral index and regional cerebral oxygen saturation

In uence of propofol concentrations on multipulse transcranial motor evoked potentials

Hala El-Habashy et al.

Propofol ensures a more stable A-line ARX index than thiopental during intubation

Neuroprotection for Scoliosis Surgery

Anesthesia for Intraoperative Neurophysiologic Monitoring of the Spinal Cord

Recovery of psychomotor function after propofol sedation is prolonged in the elderly

Increasing isoflurane concentration may cause paradoxical increases in the EEG bispectral index in surgical patients

Age-related requisite concentration of sevoflurane for adequate sedation with combined epidural-general anesthesia

The Effect of Bispectral Index Monitoring on Anesthetic Use and Recovery in Children Anesthetized with Sevoflurane in Nitrous Oxide

of end-tidal sevoflurane concentration for the smooth exchange of the tracheal tube for a laryngeal mask airway is 2.97%

Original Article. * Received for Publication: September 2, 2006 * Revision Received: December 27, 2006 * Revision Accepted: April 4, 2007

The suppression of spinal F-waves by propofol does not predict immobility to painful stimuli in humansy

Transoesophageal spinal cord stimulation for motor-evoked potentials monitoring: feasibility, safety and stability

An evaluation of anesthetic fade in motor evoked potential monitoring in spinal deformity surgeries

Effects on the Bispectral Index during Elective Caesarean Section: A Comparison of Propofol and Isoflurane

Intraoperative neurophysiological monitoring for the anaesthetist

The correlation of bispectral index with endtidal sevoflurane concentration and haemodynamic parameters in preschoolers

Manual versus target-controlled infusions of propofol

Comparing the effects of vecuronium and cisatracurium on electrophysiologic monitoring during neurosurgery: a randomized controlled study

[L addition de morphine péridurale à la ropivacaïne améliore l analgésie péridurale après une intervention chirurgicale abdominale basse]

Current Practice of Motor Evoked Potential Monitoring: Results of a Survey

The effect of desflurane on rocuronium onset, clinical duration and maintenance requirements

SEP Monitoring. Andres A Gonzalez, MD Director, Surgical Neurophysiology Keck Medical Center of USC University of Southern California

Journal of Advances in Medicine and Medical Research

Pediatric Evaluation of the Bispectral Index (BIS) Monitor and Correlation of BIS with End-tidal Sevoflurane Concentration in Infants and Children

Comparative study of effective-site target controlled infusion with standard bolus induction of propofol for laryngeal mask airway insertion

SEP Monitoring. Outline. Outline 1/22/2015. Development of SEPs Stimulation and recording techniques Predictive value of SEP Uses of SEP monitoring

Effect of landiolol on bispectral index and spectral entropy responses to tracheal intubation during propofol anaesthesia

Richard A. Beers, M.D. Professor, Anesthesiology SUNY Upstate Medical Univ VA Medical Center Syracuse, NY

Monitoring for Unconsciousness During General Anaesthesia

SEEING KETAMINE IN A NEW LIGHT

Evaluation of Postoperative Complications Occurring in Patients after Desflurane or Sevoflurane in Outpatient Anaesthesia: A Comparative Study

Chapter 25. General Anesthetics

Intraoperative Neuromonitoring. Tod B. Sloan, MD, MBA, PhD

Epidural Versus Subdural Spinal Cord Cooling: Cerebrospinal Fluid Temperature and Pressure Changes

Anesthesia depth: EEG or non-eeg derived or both?

Awareness: Where do we stand?

Hypotension after induction, corrected with 20 mg ephedrine x cc LR EBL 250cc Urine output:

Closed-Loop Control of General Anesthesia: My Clinical Experience

Why can t we get good baseline motor evoked potentials in this. patient? Laura Hemmer, M.D. Antoun Koht, M.D.

Drug Choices and Outcomes in Neuroanesthesia

Bispectral index monitoring does not improve early recovery of geriatric outpatients undergoing brief surgical procedures

General anesthesia. No single drug capable of achieving these effects both safely and effectively.

Audit and Compliance Department 1

Isoflurane compared with nitrous oxide anaesthesia for intraoperative. somatosensory-evoked potentials

Sevoflurane and isoflurane, but not propofol, decrease mivacurium requirements over time

JMSCR Vol 04 Issue 01 Page January 2016

Priming with rocuronium accelerates neuromuscular block in children: a prospective randomized study

Hypotension After Local Anesthetic Infiltration Into The Oral Submucosa During Oral And Maxillofacial Surgery

Protocol. Intraoperative Neurophysiologic Monitoring (sensoryevoked potentials, motor-evoked potentials, EEG monitoring)

Muscle relaxation and increasing doses of propofol improve intubating conditions

ANESTHESIA EXAM (four week rotation)

BIS Technology Enabling safety and quality improvements in the cardiac operating room

Depth of Anesthesia Monitoring in Cardiac Surgery. Adam Dryden MD, FRCPC University of Ottawa Heart Institute

INTUBATING CONDITIONS AND INJECTION PAIN

Closed Loop Anaesthesia Delivery System (CLADS) - Anaesthesia Robot

Spectral entropy measurement of patient responsiveness during propofol and remifentanil. A comparison with the bispectral index {

Original contribution. Department of Anesthesiology, Sapporo Medical University, School of Medicine, Sapporo, Hokkaido, Japan

INTRAOPERATIVE NEUROPHYSIOLOGICAL MONITORING FOR MICROVASCULAR DECOMPRESSION SURGERY IN PATIENTS WITH HEMIFACIAL SPASM

Depressive effect of isoflurane on motor evoked potentials in the Nubian goat

Comparison of the Hemodynamic Responses with. with LMA vs Endotracheal Intubation

O cm - 1. O cm-1) et à partir de la position la plus proximale possible jusqu'à la position finale dans le groupe B-II (19,5 ± 4,8 cm H 2

Inhalation of Isoflurane or Sevoflu. Citation Acta medica Nagasakiensia. 1996, 41

Non-therapeutic and investigational uses of non-invasive brain stimulation

EFFECTS OF NITROUS OXIDE ON AUDITORY CORTICAL EVOKED POTENTIALS AND SUBJECTIVE THRESHOLDS

A combination of alfentanil-lidocaine-propofol. better intubating conditions than a fentanyl- lidocainepropofol

INTRACEREBRAL HEMORRHAGE FOLLOWING ENUCLEATION: A RESULT OF SURGERY OR ANESTHESIA?

1- Prone position implications: Most spine cases are performed with the patient in the

Remifentanil with morphine transitional analgesia shortens neurological recovery compared to fentanyl for supratentorial craniotomy

= 0.002) 117 #!. 12, : = 0.45; P

Neuro Quiz 25 - Monitoring

Bispectral index as an indicator of anaesthetic depth during isoflurane anaesthesia in the pig

Systematic re-evaluation of intraoperative motor-evoked potential suppression in scoliosis surgery

Propofol or sevoflurane anesthesia without muscle relaxants allow the early extubation of myasthenic patients

Anesthetic Experience of Spinal Anesthesia after Sedation in Un-cooperated Elderly Patients

PDF hosted at the Radboud Repository of the Radboud University Nijmegen

Neurophysiology Lecture One : Neurophysiology and Evoked Potentials Lecture Two: Clinical Neuroanesthesia

Management of Traumatic Brain Injury (and other neurosurgical emergencies)

NVM5 NERVE MONITORING SYSTEM AN INTRODUCTION TO

The bispectral index (BIS) monitor was developed

Effects of Propofol on H-reflex in Humans

Multi-center (5 centers); United States and Canada. September 10, 1992 to April 9, 1993

An Approach to Intraoperative Neurophysiologic Monitoring of Thoracoabdominal Aneurysm Surgery

A Comparison of Spinal, Epidural, and General Anesthesia for Outpatient Knee Arthroscopy

MOTOR EVOKED POTENTIALS AND TRANSCUTANEOUS MAGNETO-ELECTRICAL NERVE STIMULATION

Change in auditory evoked potential index and bispectral index during induction of anesthesia with anesthetic drugs

Remifentanil. Addressing the challenges of ambulatory orthopedic procedures 1-3

HST-151 Clinical Pharmacology in the Operating Room

TCD in Anaesthesiology

Letter to the Editor: test occlusion under monitoring of motor-evoked potentials for giant distal

NEUROMONITORING AND ANESTHESIA CONSIDERATIONS. Martha Richter, MSN, CRNA

Cardiovascular Effects of Anesthesia for Cesarean Delivery in the Cardiac Patient

Transcription:

86 Neuroanesthesia and Intensive Care Noxious stimuli do not modify myogenic motor evoked potentials by electrical stimulation during anesthesia with propofol-based anesthesia [Des stimuli douloureux ne modifient pas les potentiels évoqués myogènes moteurs obtenus par stimulation électrique pendant l anesthésie à base de propofol] Satoki Inoue MD,* Masahiko Kawaguchi MD,* Masahiro Takahashi MD,* Meiko Kakimoto MD,* Takanori Sakamoto MD,* Katsuyasu Kitaguchi MD,* Hitoshi Furuya MD,* Tetsuya Morimoto MD, Toshisuke Sakaki MD Purpose: To investigate whether motor evoked potentials (MEP) to transcranial electrical stimulation under constant blood propofol concentration are affected by the arousing effect of surgical noxious stimuli. Methods: Twenty patients who underwent elective spinal surgery were studied. Patients were anesthetized with 50% nitrous oxide in oxygen, fentanyl, and propofol to maintain the bispectral index (BIS) score around 50. MEP in response to a multipulse transcranial electrical stimulation at stimulus sites of C3 C4 were recorded over the right abductor pollicis brevis muscle. Changes of peak-topeak amplitude and onset latency of MEP, BIS score before and after surgical stimuli were evaluated. Propofol plasma concentration was measured at the same time points. Results: Both MEP amplitude and latency did not change significantly after surgical stimuli although BIS increased significantly (48 ± 6 to 58 ± 5; P < 0.05). Plasma propofol concentration was maintained at the same level between the two measurement points (3.3 ± 0.7 to 3.3 ± 0.7 µg ml 1 ). There was no relation between BIS change and changes of MEP amplitude and latency, and propofol plasma concentration. Conclusion: MEP to the transcranial electrical stimulation under a constant and clinically appropriate blood propofol concentration are not affected by surgical noxious stimuli. Objectif : Découvrir si les potentiels évoqués moteurs (PEM) obtenus par une stimulation électrique transcrânienne, pendant le maintien d une concentration sanguine constante de propofol, sont influencés par l activation des stimuli chirurgicaux douloureux. Méthode : Vingt patients qui devaient subir une opération non urgente de la colonne vertébrale ont été étudiés. Ils ont reçu une anesthésie réalisée avec un mélange de protoxyde d azote et d oxygène à 50 %, du fentanyl et du propofol pour maintenir la valeur de l index bispectral (BIS) autour de 50. Les PEM obtenus par une stimulation électrique transcrânienne multi-impulsionnelle aux sites de C3 C4 ont été enregistrés sur le muscle court abducteur du pouce. Les changements d amplitude crête-à-crête et le temps de latence des PEM ainsi que le score du BIS avant et après les stimuli chirurgicaux ont été évalués. La concentration plasmatique de propofol a été mesurée aux mêmes moments. Résultats : L amplitude et la latence des PEM n ont pas changé de façon significative après les stimuli chirurgicaux, même si le BIS a augmenté significativement (48 ± 6 à 58 ± 5; P < 0,05). La concentration plasmatique de propofol a été maintenue au même niveau entre les deux points de mesure (3,3 ± 0,7 à 3,3 ± 0,7 µg ml 1 ). Il n y avait pas de relation entre les changements du BIS et ceux de l amplitude et de la latence des PEM, et la concentration plasmatique de propofol. Conclusion : Les PEM obtenus par stimulation électrique transcrânienne, pendant le maintien d une concentration sanguine de propofol appropriée à la situation clinique, ne sont pas influencés par les stimuli chirurgicaux douloureux. From the Department of Anesthesiology,* and Neurosurgery, Nara Medical University, Nara, Japan. Address correspondence to: Dr. Satoki Inoue, Department of Anesthesiology, Neuroanesthesia Research, VA Medical Center, UCSD, 3350 La Jolla Village Drive, San Diego, California 92161, USA. Phone: 858-552-8585, ext. 7086; Fax: 858-534-0104; E-mail: sinoue@vapop.ucsd.edu Financial support: this work was supported by Grant-in Aid for Scientific Research C2-10671439, Ministry of Education, Tokyo, Japan. Accepted for publication June 11, 2002. Revision accepted October 17, 2002. CAN J ANESTH 2003 / 50: 1 / pp 86 91

Inoue et al.: NOXIOUS STIMULI AND MMEPS 87 THE inhibition of myogenic motor evoked potentials (MEP) observed with most anesthetic agents limits the ability to titrate anesthetic levels and achieve an adequate depth of anesthesia during intraoperative MEP monitoring. 1 10 Therefore, anesthetic concentrations are generally not modified when MEP monitoring is used. In addition, these anesthetics are usually used at relatively low doses, and patients undergoing intraoperative MEP monitoring often demonstrate symptoms of light anesthesia in response to noxious stimuli during surgery. 1 10 Ideally, anesthesia for intraoperative MEP monitoring should not inhibit MEP monitoring and, simultaneously, should provide adequate anesthesia in response to surgical stimuli. Multiple investigators have documented the usefulness of computer processed electroencephalography (EEG), such as the bispectral index (BIS), to quantify assessment of anesthetic depth. 11 13 In general, anesthetic depth is affected by noxious stimuli. BIS appears to be sensitive to the changes in anesthetic depth produced by noxious stimuli, including surgery. 11 13 Furthermore, it is conceivable that noxious stimuli might also increase evoked potential signals, including MEP. If the arousing effect of surgical noxious stimuli affects MEP even under constant anesthetic concentration, the modification of monitoring results might lead to a misestimation of motor function. Simultaneously, adjustment of the anesthetic regimen would be required to provide adequate anesthesia against noxious stimuli. The present study was conducted to investigate whether MEP to transcranial electrical stimulation under constant blood propofol concentration are affected by the arousing effect of surgical noxious stimuli using BIS as an assessment of anesthetic depth. Materials and methods After Institutional approval and informed consent, 20 patients (nine men and 11 women), classified as ASA physical status I or II and scheduled to undergo elective cervical or lumbar spinal surgery, were enrolled. All patients were premedicated with roxatidine (H 2 blocker) 75 mg orally two hours preoperatively. Anesthesia was induced with propofol 1.5 2.5 mg kg 1, fentanyl 7 8 µg kg 1 and vecuronium 0.1 mg kg 1 and maintained with 50% nitrous oxide in oxygen, propofol 3 6 mg kg 1 hr 1 and fentanyl 4 5 µg kg 1 hr 1. After the trachea was intubated, the lungs were ventilated mechanically to maintain PaCO 2 between 35 40 mmhg. Systolic blood pressure was maintained at 100 130 mmhg. When hypotension or hypertension was observed, a bolus of ephedrine or nicardipine was administered. Muscle relaxation was monitored and controlled by the following. Compound muscle action potentials from the right abductor pollicis brevis muscle (APB) in response to supramaximal electrical stimulation (constant-current square wave pulses of 0.2 msec duration) of the median nerve at the wrist were recorded as a means of assessing the degree of neuromuscular blockade. This response is known in the neurophysiologic literature as the muscle (M) response. 14 The control value was defined as that at admission to the operating room without the effect of vecuronium. The level of M- response was maintained at 40 50% of control with a continuous infusion of vecuronium. Other monitoring included the electrocardiogram, intraarterial pressure, oxygen saturation by pulse oxymetry, end-tidal CO 2 concentration, and rectal temperature. Transcranial stimulation was performed using a multipulse device (D-185; Digitimer, Welwyn, Garden City, UK). A train-of-five pulses with an interstimulus interval of 2 msec were used as in our previous study. 7 The outputs were delivered to the scalp by a single pair of 14.5 mm silver disc electrodes, applied to C3 (anode) and C4 (cathode); (international 10 20 system). Five consecutive stimulations at C3 and C4 were made. The stimulus intensity was set at 700 V. MEP were recorded from the right APB (the same site as for recording of M-response). Evoked myographic responses were amplified with a 0.3 3 khz band pass filter and displayed on oscilloscopes (MEB- 5508; Nihon Koden, Tokyo, Japan). Experimental MEP study was performed after the induction of anesthesia and before the start of surgery. Peak-to-peak amplitudes and onset latencies were monitored. The mean amplitude and latency were calculated from five consecutive responses to stimulation using a pair of C3 C4 disc electrodes. The EEG signal was recorded using the Aspect A- 1000 EEG monitor (Aspect Medical System, Natick, MA, USA). Silver-silver chloride EEG pads (Zipprep; Aspect Medical Systems) were attached to patient s forehead according to a standard montage. 15 The low - and high - frequency filters were set to 0.25 Hz and 30 Hz, respectively. By ten minutes before the start of surgery, the propofol infusion rate was adjusted to maintain stable BIS score around 50. The propofol infusion rate was not changed thereafter. To investigate whether MEP to transcranial electrical stimulation under constant blood propofol concentration are affected by arousing effect of surgical noxious stimuli, MEP were collected two minutes before and after the start of surgery. In most cases, approximately 60 min had passed after induction of anesthesia when the first MEP collections were conducted. The start of surgery in this

88 CANADIAN JOURNAL OF ANESTHESIA FIGURE 1 Amplitude of motor evoked potentials (MEP) from the right abductor pollicis brevis muscle to transcranial electrical stimulation at stimulus sites of C3 C4 before and after the start of surgery. Horizontal bars represent the tenth, 25th, median, 75th, and 90th percentiles. One participant was excluded from the analysis because MEP were not elicited (n = 19). Before: two minutes before the start of surgery; after: two minutes after the start of surgery. study was defined when the initial surgical incision was made. No interventions were made to standardize the degree of stimulation by surgeons because surgical sites were different among patients. At same time points, BIS score, mean arterial pressure (MAP), and heart rate (HR) were recorded and blood samples were collected to confirm that propofol plasma concentration remained constant. Five millilitres of blood were drawn into a heparinized syringe, collected into a glass tube, centrifuged for ten minutes at 3000 rpm, and 2.0 ml of plasma were stored at -20 C for propofol analysis. Plasma concentrations of propofol were determined by high-performance liquid chromatography. Statistical analysis Because MEP amplitude-related data did not appear to be distributed normally, they are presented as median, and tenth, 25th, median, 75th, and 90th percentiles. MEP latency-related data are expressed as mean ± SD. A paired t test to compare physiologic variables, BIS score, propofol concentration, and latency of MEP between the two time points, FIGURE 2 Relationships between changes in bispectral index score (BIS) and that of motor evoked potentials (MEP) amplitude and latency, and propofol plasma concentration before and after the start of surgery (n = 19). Wilcoxon signed-ranks test was used to compare amplitudes of MEP. The relationships between BIS and MEP amplitude and latency, and propofol concentration before and after the start of surgery were evaluated by Pearson s correlation. Because these values varied with individual patients, especially MEP amplitude and BIS score, the relationships were also analyzed using percent change of these values. Any change of MEP amplitude of more than 50% was defined as a significant modification according to Zhou et al. 16 because within- patient variability of MEP, which may lead to a misinterpretation of the MEP, is generally observed. 17,18 Results were considered significant at P < 0.05.

Inoue et al.: NOXIOUS STIMULI AND MMEPS 89 Results Preoperative motor function was normal in all patients. Their age was 57 ± 19 yr, height 159 ± 9 cm, and weight 55 ± 10 kg (mean ± SD). Disease in the patients included lumbar disc hernia (n = 9), cervical disc hernia (n = 5), ossification of the posterior spinal ligament (n = 3), compression fracture of the lumbar vertebral body (n = 2), and spinal cord tumour (n = 1). MEP were recorded successfully in all but one patient. MEP peak-to-peak amplitude did not change significantly after the start of surgery (Figure 1) although BIS score did increase significantly (48 ± 6 to 58 ± 5; P < 0.05). MEP latency did not change (20.9 ± 1.8 to 20.9 ± 1.9 sec). Plasma propofol concentration was constant (3.3 ± 0.7 to 3.3 ± 0.7 µg ml 1 ). Absolute and percent changes in BIS were not related to changes in MEP latency or amplitude or propofol concentration (Figures 2 and 3). MAP and HR did not change significantly (78 ± 9 to 81 ± 11 mmhg and 63 ± 10 to 67 ± 14 beats min 1, respectively). No patient showed a significant positive change of MEP amplitude. FIGURE 3 Relationships between percent change of bispectral index score (BIS) and that of motor evoked potentials (MEP) amplitude and latency, and propofol plasma concentration before and after the start of surgery (n = 19). Discussion These results show that noxious stimuli strong enough to change BIS values do not affect MEP to five-pulse transcranial electrical stimulation with a constant plasma propofol concentration. Therefore, we can conclude that MEP can be obtained consistently regardless of anesthetic depth (as evaluated by BIS) if the anesthetic regimen is not changed. Although a number of authors have reported the effects of anesthetics on MEP induced by motor cortex stimulation, the effect of noxious surgical stimuli on intraoperative MEP monitoring remains unclear. The most plausible explanation for our results is that the effect of an anesthetic on the spinal cord is independent of its supraspinal effects. 19 24 It is likely that synaptic transmission is the primary site at which anesthetics suppress MEP, specifically at the level of the spinal interneuronal or motoneuronal systems. 4 These spinal systems and their evoked potentials do not appear to be affected by the change in anesthetic depth at the supraspinal level. Otherwise, MEP amplification by surgical stimuli might be masked by fivepulse transcranial electrical stimulation, which is an effective way of achieving discharge in a large set of spinal motoneurons. In other words, the amplification by surgical stimuli is only allowed to go so far; however, our study design did not allow the physiology of this response to be determined. There are several limitations to the study protocol that must be discussed. The effects of different propofol concentrations or BIS scores on our results could be important. In light of ethical concerns, we wanted to avoid higher BIS scores using lower propofol doses. It has been reported that a BIS of 40 55 is usually required during general anesthesia. We targeted a BIS of approximately 50 for this study, which required a plasma propofol concentration of over 3 µg ml 1. 11 13 This is recognized as a clinically appropriate concentration and probably higher than those used in other MEP studies. 25 Using a clinically appropriate propofol-based anesthetic, may, possibly, have limited our ability to test our study hypothesis. However, the surgical stimuli appeared to be sufficient to change anesthetic depth even under clinically appropriate propofol-based anesthesia.

90 CANADIAN JOURNAL OF ANESTHESIA The question may also be raised as to whether the anesthetic depth truly changed after the noxious stimuli. The significance of an increase in mean BIS from 48 58 is unclear. The absence of an increase in MAP or HR despite an increase in BIS raises questions about the clinical significance of the BIS increase. Yet, we believe the increase in BIS indicated a change in anesthetic depth, as BIS scores have been reported to be clinically reliable in this assessment. 11 13 Furthermore, BIS increases in response to noxious stimuli prior to or in the absence of hemodynamic or motor reactivity as evidence of inadequate anesthesia in some patients. 26 Our results support the use of MEP monitoring; however, the response to alterations in anesthetic depth following noxious stimuli remains unclear, creating a dilemma between the need to provide adequate anesthesia and the desire to consistently obtain MEP recordings. It is true that the use of agents that depress MEP or modifications to their concentration in response to noxious stimuli should be avoided. As our results showed, it is also true that anesthetic depth is changed by noxious stimuli during MEP monitoring. Over this decade, methods of intraoperative MEP monitoring have developed greatly, but we should strive to improve the quality of anesthesia during intraoperative MEP monitoring. In conclusion, we have demonstrated that MEP to transcranial electrical stimulation under a constant and clinically appropriate propofol blood concentration are not affected by surgical noxious stimuli. Acknowledgement The authors thank Dr. Daniel P. Davis (Assistant Professor of the Department of Emergency Medicine, University of California, San Diego, USA) for his editorial assistance. References 1 Kalkman CJ, Drummond JC, Ribberink AA, Patel PM, Sano T, Bickford RG. Effects of propofol, etomidate, midazolam, and fentanyl on motor evoked responses to transcranial electrical or magnetic stimulation in humans. Anesthesiology 1992; 76: 502 9. 2 Kalkman CJ, Drummond JC, Ribberink AA. Low concentrations of isoflurane abolish motor evoked responses to transcranial electrical stimulation during nitrous oxide/opioid anesthesia in humans. Anesth Analg 1991; 73: 410 5. 3 Kawaguchi M, Inoue S, Kakimoto M, et al. The effect of sevoflurane on myogenic motor-evoked potentials induced by single and paired transcranial electrical stimulation of the motor cortex during nitrous oxide/ketamine/fentanyl anesthesia. J Neurosurg Anesthesiol 1998; 10: 131 6. 4 Zentner J, Albrecht T, Heuser D. Influence of halothane, enflurane, and isoflurane on motor evoked potentials. Neurosurgery 1992; 31: 298 305. 5 van Dongen EP, ter Beek HT, Aarts LP, et al. The effect of two low-dose propofol infusions on the relationship between six-pulse transcranial electrical stimulation and the evoked lower extremity muscle response. Acta Anaesthesiol Scand 2000; 44: 799 803. 6 van Dongen EP, ter Beek HT, Schepens MA, et al. The influence of nitrous oxide to supplement fentanyl/lowdose propofol anesthesia on transcranial myogenic motor-evoked potentials during thoracic aortic surgery. J Cardiothorac Vasc Anesth 1999; 13: 30 4. 7 Kawaguchi M, Sakamoto T, Inoue S, et al. Low dose propofol as a supplement to ketamine-based anesthesia during intraoperative monitoring of motor-evoked potentials. Spine 2000; 25: 974 9. 8 Ubags LH, Kalkman CJ, Been HD, Porsius M, Drummond JC. The use of ketamine or etomidate to supplement sufentanil/n 2 O anesthesia does not disrupt monitoring of myogenic transcranial motor evoked responses. J Neurosurg Anesthesiol 1997; 9: 228 33. 9 Thees C, Scheufler KM, Nadstawek J, et al. Influence of fentanyl, alfentanil, and sufentanil on motor evoked potentials. J Neurosurg Anesthesiol 1999; 11: 112 8. 10 Zentner J, Thees C, Pechstein U, Scheufler KM, Wurker J, Nadstawek J. Influence of nitrous oxide on motorevoked potentials. Spine 1997; 22: 1002 6. 11 Vernon JM, Lang E, Sebel PS, Manberg P. Prediction of movement using bispectral electroencephalographic analysis during propofol/alfentanil or isoflurane/alfentanil anesthesia. Anesth Analg 1995; 80: 780 5. 12 Sebel PS, Lang E, Rampil IJ, et al. A multicenter study of bispectral electroencephalogram analysis for monitoring anesthetic effect. Anesth Analg 1997; 84: 891 9. 13 Struys MM, De Smet T, Versichelen LF, Van de Velde S, Van den Broecke R, Mortier EP. Comparison of closedloop controlled administration of propofol using bispectral index as the controlled variable versus standard practice controlled administration. Anesthesiology 2001; 95: 6 17. 14 Kalkman CJ, Drummond JC, Kennelly NA, Patel PM, Partridge BL. Intraoperative monitoring of tibialis anterior muscle motor evoked responses to transcranial electrical stimulation during partial neuromuscular blockade. Anesth Analg 1992; 75: 584 9. 15 Rampil IJ, Holzer JA, Quest DO, Rosenbaum SH, Correll JW. Prognostic value of computerized EEG analysis during carotid endarterectomy. Anesth Analg 1983; 62: 186 92.

Inoue et al.: NOXIOUS STIMULI AND MMEPS 91 16 Zhou HH, Kelly PJ. Transcranial electrical motor evoked potential monitoring for brain tumor resection. Neurosurgery 2001; 48: 1075 81. 17 van Dongen EP, ter Beek HT, Schepens MA, et al. Within patient variability of lower extremity muscle responses to transcranial electrical stimulation with pulse trains in aortic surgery. Clin Neurophysiol 1999; 110: 1144 8. 18 Woodforth IJ, Hicks RG, Crawford MR, Stephen JP, Burke DJ. Variability of motor-evoked potentials recorded during nitrous oxide anesthesia from the tibialis anterior muscle after transcranial electrical stimulation. Anesth Analg 1996; 82: 744 9. 19 Antognini JF, Schwartz K. Exaggerated anesthetic requirements in the preferentially anesthetized brain. Anesthesiology 1993; 79: 1244 9. 20 Rampil IJ, Mason P, Singh H. Anesthetic potency (MAC) is independent of forebrain structures in the rat. Anesthesiology 1993; 78: 707 12. 21 Antognini JF, Carstens E, Tabo E, Buzin V. Effect of differential delivery of isoflurane to head and torso on lumbar dorsal horn activity. Anesthesiology 1998; 88: 1055 61. 22 Antognini JF, Wang XW, Piercy M, Carstens E. Propofol directly depresses lumbar dorsal horn neuronal responses to noxious stimulation in goats. Can J Anesth 2000; 47: 273 9. 23 Zhou HH, Jin TT, Qin B, Turndorf H. Suppression of spinal cord motoneuron excitability correlates with surgical immobility during isoflurane anesthesia. Anesthesiology 1998; 88: 955 61. 24 Antognini JF, Carstens E, Buzin V. Isoflurane depresses motoneuron excitability by a direct spinal action: an F- wave study. Anesth Analg 1999; 88: 681 5. 25 Casati A, Fanelli G, Casaletti E, et al. Clinical assessment of target-controlled infusion of propofol during monitored anesthesia care. Can J Anesth 1999; 46: 235 9. 26 Luginbuhl M, Schnider TW. Detection of awareness with the bispectral index: two case reports. Anesthesiology 2002; 96: 241 3.