Evaluation of oesophageal reflectance pulse oximetry in major burns patients

Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

City, University of London Institutional Repository

City, University of London Institutional Repository

Investigation of the human oesophagus as a new monitoring site for blood oxygen saturation

Photoplethysmographic measurements from central nervous system tissue

City, University of London Institutional Repository

PHOTOPLETHYSMOGRAPHY AND PULSE OXIMETRY OF BODY CAVITIES AND ORGANS*

Dual channel photoplethysmography studies of cardio-vascular response to the body position changes

Investigation of photoplethysmographs from the anterior fontanelle of neonates

Measuring Heart Rate and Blood Oxygen Levels for Portable and Wearable Devices

Correlation of Ratio of Ratio of Near Infrared Vs Infrared Photoplethysmograph Spectroscopy for the Non-Invasive Measurement of Haemoglobin

City, University of London Institutional Repository

City, University of London Institutional Repository

Biomedical Instrumentation D. The Photoplethysmogram

Journal of Faculty of Engineering & Technology DESIGN AND IMPLEMENTATION OF A WEARABLE HEALTH DEVICE

Design a system of measurement of heart rate, oxygen saturation in blood and body temperature with non-invasive method

Dr. D.McG.Clarkson Determining the Accuracy of SpO2 Values

Oximeters. Hsiao-Lung Chan, Ph.D. Dept Electrical Engineering Chang Gung University, Taiwan

Optical measurement of blood flow changes in spinal cord injury

Design and Development of Non-Invasive Prototype to Measure Pulse Rate, Blood Glucose and Oxygen Saturation Level in Arterial Blood

Assessing Agreement Between Methods Of Clinical Measurement

Estimation of Haemoglobin Using Non-Invasive Technique

Research Journal of Pharmaceutical, Biological and Chemical Sciences

Optical Sensor System for Hemoglobin Measurement

Non-Invasive Method of Blood Pressure Measurement Validated in a Mathematical Model

Biomedical Instrumentation E. Blood Pressure

Blood Pressure Estimation Using Photoplethysmography (PPG)

ANALYSIS OF PHOTOPLETHYSMOGRAPHIC SIGNALS OF CARDIOVASCULAR PATIENTS

ORIGINAL RESEARCH. Effect of road traffic accident contaminants on pulse oximetry among normoxaemic volunteers

How Does Pulse Oximetry Work? SpO2 Sensors Absorption at the Sensor Site Oxyhemoglobin Dissociation Curve

Oximeters. Hsiao-Lung Chan, Ph.D. Dept Electrical Engineering Chang Gung University, Taiwan

City, University of London Institutional Repository

Optical sensor for Indian Siddha Diagnosis System

Development of an Optical Sensor Based System for Detection and Monitoring of Hemoglobin in Blood

A Three-Wavelength Pulse Oximeter for Carboxyhemoglobin Determination

A bioimpedance-based cardiovascular measurement system

Optical non-invasive methods for characterization of the human health status

Signal Quality Analysis in Pulse Oximetry: Modelling and Detection of Motion Artifact

Pulse oximetry revisited. Dr Liesel Bösenberg Specialist Physician and Fellow in Critical Care Kalafong Hospital University of Pretoria

BLOOD GLUCOSE LEVEL MONITORING BY NONINVASIVE METHOD USING NEAR INFRA RED SENSOR

Oxygen Saturation Monitors & Pulse Oximetry. D. J. McMahon rev cewood

Pulse oximetry in the accident and emergency department

Design of Remote Monitoring System for the Detection of Vital Signs

Edwards FloTrac Sensor & Performance Assessments of the FloTrac Sensor and Vigileo Monitor

ISSN: [Cortes* et al., 7(3): March, 2018] Impact Factor: 5.164

ADVANCED PATIENT MONITORING DURING ANAESTHESIA: PART ONE

Assessment of Photoplethysmography Method in Extraction of Hemoglobin Concentration

Non-Invasive PCO 2 Monitoring in Infants Hospitalized with Viral Bronchiolitis

Oxygen Level Measurement Techniques: Pulse Oximetry

Cerebral Arterial Oxygen Saturation Measurements using a Fiber-optic Pulse Oximeter

TEPZZ _ 849 A_T EP A1 (19) (11) EP A1. (12) EUROPEAN PATENT APPLICATION published in accordance with Art.

Muscle OxyGen monitor. The Science Behind Moxy

Continuous Monitoring of Blood Pressure Based on Heart Pulse Analysis

Heart Abnormality Detection Technique using PPG Signal

Pulse Oximeter Accuracy Study

Cerebral Arterial Oxygen Saturation Measurements Using a Fiber-Optic Pulse Oximeter

Heart Rate Monitoring System Using Lab View

Noninvasive Blood Glucose Analysis using Near Infrared Absorption Spectroscopy. Abstract

Streamline Automation, LLC

Pulse Oximeter Accuracy Study

Competitive Intelligence Report Technology & Patents

DC Unbalance Tolerance Testing in PSE s

Clinically Available Optical Topography System

SUBJECT INFORMATION AND CONSENT FORM

Estimation of Systolic and Diastolic Pressure using the Pulse Transit Time

An assessment of the accuracy of pulse oximeters

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the PreSep oximetry catheter for

Pulse oximetry use in small animals

The Photoplethysmography Imaging Device for Non-contact Monitoring of Sympathetic Blocks

JAMES R. KNIGHT

vasolab 320 Vascular Diagnosis Center

City, University of London Institutional Repository

Western Hospital System. PSG in History. SENSORS in the field of SLEEP. PSG in History continued. Remember

Light is wearable Health Monitoring and Fitness Tracking Light is OSRAM

Volume 2, Number 4, 2016 Pages Jordan Journal of Electrical Engineering ISSN (Print): , ISSN (Online):

International Journal of Modern Trends in Engineering and Research e-issn No.: , Date: 2-4 July, 2015

Authorship Abstract Acknowledgements Table of Figures Table of Tables Abbreviations Introduction...

Online Supplementary Appendix

In-Ear Microphone Equalization Exploiting an Active Noise Control. Abstract

Non-invasive Hemoglobin Measurement for Anemia Diagnosis

E SERIES. Contents CALIBRATION PROCEDURE. Version 2.0

Medical Electronics Dr. Neil Townsend Michaelmas Term 2001 ( The story so far.

GUIDANCE NOTE. Application of MEMS Ultrasonic Transducers to Flow Measurement.

Solar Powered Non-Invasive Pulse Oximeter and Heart Rate Meter

RESPONSE OF 10 PULSE OXIMETERS TO AN IN VITRO TEST SYSTEM

Accuracy of Beat-to-Beat Heart Rate Estimation Using the PulseOn Optical Heart Rate Monitor

Noninvasive Detection of Bilirubin in Discrete Vessels

Testing Masimo rainbow Technology with vpad-a1 1. Background

British Journal of Anaesthesia 104 (6): (2010) doi: /bja/aeq092 Advance Access publication April 23, 2010

for Heart-Health Scanning

POLYSOMNOGRAPHIC MONITORING USING REAL TIME ANALYSIS

The role of pulse oximetry in the accident and emergency department

ECG Acquisition System and its Analysis using MATLAB

Diabetic diagnose test based on PPG signal and identification system

Hybrid EEG-HEG based Neurofeedback Device

Chandra Ramamoorthy MBBS; FRCA (UK) Professor of Anesthesiology, Stanford University. Director of Pediatric Cardiac Anesthesiology

Is Hypoxia common despite oxygen treatment in the Acute Medical ward?

EXPERIMENTS WITH BLOOD PRESSURE MONITORING USING ECG AND PPG

Transcription:

Kyriacou, P. A., Pal, S. K., Langford, R. & Jones, DP (2006). Electro-optical techniques for the investigation of oesophageal photoplethysmographic signals and blood oxygen saturation in burns. Measurement & Control, 39(3), pp. 77-79. doi: 10.1177/002029400603900302 City Research Online Original citation: Kyriacou, P. A., Pal, S. K., Langford, R. & Jones, DP (2006). Electro-optical techniques for the investigation of oesophageal photoplethysmographic signals and blood oxygen saturation in burns. Measurement & Control, 39(3), pp. 77-79. doi: 10.1177/002029400603900302 Permanent City Research Online URL: http://openaccess.city.ac.uk/14688/ Copyright & reuse City University London has developed City Research Online so that its users may access the research outputs of City University London's staff. Copyright and Moral Rights for this paper are retained by the individual author(s) and/ or other copyright holders. All material in City Research Online is checked for eligibility for copyright before being made available in the live archive. URLs from City Research Online may be freely distributed and linked to from other web pages. Versions of research The version in City Research Online may differ from the final published version. Users are advised to check the Permanent City Research Online URL above for the status of the paper. Enquiries If you have any enquiries about any aspect of City Research Online, or if you wish to make contact with the author(s) of this paper, please email the team at publications@city.ac.uk.

Electro-optical techniques for the investigation of oesophageal photoplethysmographic signals and blood oxygen saturation in burns P A Kyriacou 1, S K Pal 2, R M Langford 3 and D P Jones 4 1 School of Engineering and Mathematical Sciences, City University, London, UK 2 St Andrew s Centre for Plastic Surgery & Burns, Broomfield Hospital, Chelmsford, Essex, 3 Anaesthetic Laboratory & Department, St.Bartholomew s Hospital, London, UK 4 Medical Electronics & Physics, Department of Engineering, Queen Mary University of London, London, UK Executive summary Pulse oximetry is widely used in anaesthesia and intensive care monitoring. It is a valuable, non-invasive optical monitoring technique used for continuous measurement of arterial blood oxygen saturation (SpO 2 ). Sites for pulse oximeter sensors are frequently difficult to find in patients with major thermal injury. Therefore blood oxygen saturation readings are often unobtainable at just the time when they would be most valuable. An oesophageal SpO 2 probe has been designed to record reliable photoplethysmographic (PPG) signals and SpO 2 values from the oesophagus of burned patients. Seven adult patients were studied. Good quality oesophageal PPG signals with large amplitudes were measured from various depths within the oesophagus. The optimal monitoring oesophageal depth ranged from 13 cm to 20 cm, measured from the upper lip. It was found that the oesophageal pulse oximeter saturation results were in good agreement with those from the CO-oximeter. This study suggests that the

oesophagus can be used as an alternative site for monitoring arterial blood oxygen saturation by pulse oximetry in burned patients. Introduction Non-invasive continuous arterial blood oxygen saturation measurement by pulse oximetry is widely acknowledged to be one of the most important technological advances in clinical monitoring 1. Pulse oximeters are routinely used to monitor patients in anaesthetic rooms, operating theatres, recovery rooms and intensive care units. However, sites for pulse oximeter sensors are frequently difficult to find in patients with major thermal injury. Standard sites such as fingers or toes may be affected by the burn, unsuitable due to the use of tourniquets during surgery, or in some cases absent. Therefore blood oxygen saturation (SpO 2 ) readings are often unobtainable at just the time when they would be most valuable. Pulse oximeters estimate arterial blood oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the pulsatile photoplethysmographic (AC PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared AC PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding DC photoplethysmographic components, arterial blood oxygen saturation (SpO 2 ) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals 2.

Studies have shown that measurable PPG signals and SpO 2 values can be detected in the oesophagus of healthy adult patients during anaesthesia and patients undergoing cardiothoracic surgery 3-8. The present study was aimed at evaluating the reliability of oesophageal pulse oximetry in major burns patients. Materials and Methods A reflectance electro-optical oesophageal pulse oximetry probe comprising miniature infrared (880 nm) and red (655 nm) emitters and a photodetector has been constructed (Figure 1). The silicon diode photodetector is mounted between the red and infrared emitters to detect radiation back scattered by the tissue. A separation of 5 mm between the emitters and the photodetector provides good signal-to-noise ratio and adequate pulsatile signals. The probe was designed to fit into a conventional disposable transparent gastric tube, 20 French gauge, which is sealed at the distal end 6. Infrared emitter Red emitter photodetector 3.8 mm Gastric tube (French 20) 5.0 mm photodetector 1.0 mm 20.0 mm copper board 3.5 mm 4.66 mm 6.66 mm Figure 1: Side and cross sectional view of the reflectance electro-optical oesophageal pulse oximetry probe. In the cross sectional view the probe is shown inserted in the gastric tube

An isolated data acquisition and processing system, shown in Figure 2, has been developed to detect, process, record and display the red and infrared AC and DC PPG signals and estimate SpO 2 values from the oesophagus. Figure 2: Block diagram of the oesophageal pulse oximetry processing system The emitters, red (R) and infrared (IR), are driven by constant current sources which are controlled by analogue switches which turn the red and infrared emitters on and off at 75 Hz. The photodetector detects the energy backscattered by the tissue and gives an output current proportional to the detected light intensity. The output of the current-to-voltage (I-V) amplifier contains multiplexed PPG signals corresponding to red and infrared wavelengths. The signal from the current-to-voltage amplifier passes to a demultiplexer synchronised to the master clock, which separates the red (R) and infrared (IR) signals. The two signals (R and IR) are then passed through low pass filters to eliminate high-frequency switching transients and are then transmitted across an isolation barrier. Two isolation amplifiers (Burr-Brown ISO122) are used to isolate the patient side of the PPG channel from the output side. The

signals on the output side are then filtered to extract the AC and DC PPG components for each wavelength. The output signals are digitised using a 16-bit analogue-to-digital card (ADC) (National Instruments DAQCard-AI-16XE-50) and further analysed by a virtual instrument implemented in LabView on a laptop computer. PPG traces corresponding to infrared and red wavelengths from the oesophagus are obtained simultaneously and displayed on the laptop screen. Following Local Research Ethical Committee approval and after obtaining informed, written consent, seven patients with major burns admitted to burns intensive care were recruited for the study. The five men and two women ranged in age between 26 and 52 years. The total body surface area burnt ranged between 28% and 90%. A nasogastric tube containing the reflectance pulse oximetry sensor was placed in each patient s oesophagus (Figure 3). The PPG signals were recorded at various depths in the oesophagus. Arterial blood samples were taken for estimation of oxygen saturation using a CO-oximeter. A peripheral commercial pulse oximeter saturation probe was also connected to the toe of each patient. Figure 3: The oesophageal PPG/SpO 2 probe contained within the stomach tube is seen placed in the oesophagus via the mouth

Linear Regression analysis was used to compare the blood oxygen saturation results from the oesophageal pulse oximeter with those from CO-oximetry. It has been suggested that Linear Regression analysis is appropriate when calibrating an approximate or simple method (like the oesophageal pulse oximeter) with a precise method (such as CO-oximetry) 9. A Bland and Altman between-method differences analysis was performed to calculate the levels of agreement between the oesophageal and commercial finger probes 9. Results Measurable PPG traces were obtained from the oesophagus in all patients (see Figure 4). The oesophageal PPG signals recorded from all patients were of good quality and large amplitudes. The optimal monitoring oesophageal depth ranged from 13 cm to 20 cm, measured from the upper lip (mean ± SD: 15.6 ± 1.8 cm). Figure 4: Real time oesophageal PPG traces from a burned patient

A total of 19 pairs of data points, obtained from the CO-oximeter and the oesophageal pulse oximeter, from all seven patients were used for the regression analysis, which gave the estimated slope and intercept of the regression line. A plot of SpO 2 readings obtained from the reflectance oesophageal pulse oximeter (OES SpO 2 ) against the SaO 2 values from the CO-oximeter is shown in Figure 5. The equation of the best fit linear regression line is: (OES SpO 2 ) = 33.278 + 0.666 (CO-ox SaO 2 ) (the solid line in Figure 5); r 2 = 0.49; Standard Error of Estimate (SEE) = 0.64; p<0.001. The dashed line represents the line of identity. The mean (± SD) of the differences between the oesophageal pulse oximeter SpO 2 values and the corresponding CO-oximeter readings (OES SpO 2 - CO-ox SaO 2 ) is 0.50 ± 0.69%. 100 Oesophageal SpO 2 % 98 96 94 92 90 90 92 94 96 98 100 CO-ox SaO 2 % Figure 5: Pot of SpO 2 measurements obtained from the oesophageal pulse oximeter (OES SpO 2 against SaO 2 from the CO-oximetry (CO-ox SaO 2 ) for 7 patients. The solid line represents the best fit linear regression line: (OES SpO 2 ) = 33.278 + 0.66 (CO-ox SaO 2 ); r 2 = 0.49; SEE = 0.64; p<0.001. The dashed line represents identity.

Figure 6 shows a plot of SpO 2 readings obtained from the commercial toe (transmittance) pulse oximeter (CT SpO 2 ) against the SaO 2 values from the CO-oximeter. The equation of the best fit linear regression line was: (CT SpO 2 ) = -53.854 + 1.550 (CO-ox SaO 2 ); r 2 = 0.61; SEE = 1.15; p<0.001. The mean and standard deviation of the differences between the commercial toe pulse oximeter and the CO-oximeter readings (CT SpO 2 - CO-ox SaO 2 ) is 0.11 ± 1.23 %. 100 Commercial toe SpO 2 % 98 96 94 92 90 90 92 94 96 98 100 CO-ox SaO 2 % Figure 6: Plot of SpO 2 measurements obtained from the commercial toe pulse oximeter (CT SpO 2 ) against SaO 2 from the CO-oximetry (CO-ox SaO 2 ) for 7 patients. The solid line represents the best fit linear regression line: (CT SpO 2 ) = -53.854 + 1.550 (CO-ox SaO 2 ); r 2 = 0.61; SEE = 1.15; p<0.001. The dashed line represents identity. Ninety two sets of blood oxygen saturation data points from the seven patients were used to compare the oesophageal and the commercial toe pulse oximeters. Since neither can be regarded as a gold standard, the between-method differences analysis as suggested by Bland and Altman 9 was used to compare these two pulse oximeters.

Figure 7 is a plot of the difference between the commercial toe (CT) and oesophageal (OES) SpO 2 values against their mean. As no obvious relation between the difference and the mean is revealed in Figure 7, a calculation of the bias, estimated by the mean difference (d) and the standard deviation of the differences (s) was performed to assess the degree of agreement between the two methods. The bias (d) (commercial pulse oximeter minus oesophageal pulse oximeter) was 0.4% and the standard deviation (s) was 2.1%. The limits of agreement for the SpO 2 data (commercial toe and oesophageal) were, therefore: d - 2s = 0.4 - (2*2.1) = -3.6 % d + 2s = 0.4 + (2*2.1) = 4.6 % 8 6 (CT SpO 2 - OES SpO 2 ) % 4 2 0-2 -4 Mean + 2SD Mean Mean - 2SD -6 95 96 97 98 99 100 101 (CT SpO 2 + OES SpO 2 )/2 % Figure 7 The difference between blood oxygen saturation values from the commercial toe pulse oximeter (CT SpO 2 ) and SpO 2 readings obtained from the reflectance oesophageal pulse oximeter (OES SpO 2 ) plotted against their mean for all seven patients.

Conclusion The aim of this study was to evaluate the reliability of oesophageal pulse oximetry in major burns patient. Good quality oesophageal PPG signals with large amplitudes were measured from various depths within the oesophagus. The optimal monitoring oesophageal depth ranged from 13 cm to 20 cm, measured from the upper lip. It was found that the oesophageal pulse oximeter saturation results were in good agreement with those from the CO-oximeter (see Figure 3). In a direct comparison between the oesophageal and commercial toe pulse oximeters, using Bland and Altman analysis, the SpO 2 results from the two instruments were in very satisfactory agreement. Although there is some scatter the bias between them is only 0.4%. The limits of agreement from the analysis were 4.6 to -3.6 %. In summary, the data suggest that oesophageal reflectance pulse oximetry may be a reliable and useful alternative method for monitoring continuous oxygen saturation in major burns patients. Acknowledgement We gratefully acknowledge the financial support of the University of London Central Research Fund and the R&D Eastern Region. References 1. Dorlas, J. C., and Kuipers, A. H., Pulse oximetry--principle and first experiences during anesthesia, Acta Anaesthesiol Belg. 38(2), 133-138, 1987.

2. Mendelson, Y., and Ochs, B. D., Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography, IEEE Transactions on Biomedical Engineering 35, 798-805, 1988. 3. Kyriacou, P.A., Moye, A. R., Gregg, A., Choi, D. M. A., Langford, R. M., and Jones, D. P., A system for investigating oesophageal photoplethysmographic signals in anaesthetized patients, Medical & Biological Engineering & Computing 37(5), 639-643, 1999. 4. Kyriacou, P.A., Moye, A. R., Choi, D. M. A., Langford, R. M., and Jones, D. P., Investigation of the human oesophagus as a new monitoring site for blood oxygen saturation, Physiological Measurement 22(1), 223-232, 2001. 5. Kyriacou, P.A., Powell, S., Langford, R. M., and Jones, D. P., Investigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients, Physiological Measurement 23(3), 533-545, 2002. 6. Kyriacou, P.A., Powell, S., Langford, R. M., and Jones, D. P., Esophageal Pulse Oximetry Utilizing Reflectance Photoplethysmography, IEEE Transactions of Biomedical Engineering 49(11), 1360-1368, 2002. 7. Kyriacou, P.A., Powell, S., Jones, D. P., and Langford, R. M., Evaluation of oesophageal pulse oximetry in cardiothoracic surgery patients, Anaesthesia 58(5), 422-427, 2003. 8. Kyriacou, P. A., Pulse Oximetry in the oesophagus, Physiological Measurement 27, R1-R35, 2006. 9. Bland, J. M., and Altman, D. G., Statistical methods for assessing agreement between two methods of clinical measurement, Lancet 1, 307-310, 1986.